Circuit Breakersand
Busbars
Circuit Breakers
Altech’s Circuit Breaker Line
• UL1077 (R-Series)
• UL508 (V-EA Series)
• UL489 (L-Series, AB-Series)
Circuit Breakers
R-Series(UL1077 Recognized Supplementary Protector)
• Short Circuit Withstand Rating 10kA@480Y/277VAC (48VDC rating self-certified)
• B, C, D Trip Curve (0.5-63A)• 1,2,3,4 pole• Accessories: Add-on Neutral Pole, Shunt Trip, Undervoltage Trip,
Auxiliary Contact • UL listed Busbars
Circuit Breakers
V-EA Series(UL508 listed Manual Motor Controller)
• Short Circuit Withstand Rating 10kA@480Y/277VAC, 50/60Hz
• B (1-63A), C (0.3-63A), D (0.3-63A)), E (0.3-63A), G (0.3-63A), Z (0.3-50A) Trip Curve
• 1,2,3,4 pole
• 1 pole plus Neutral
• Accessories: Add-on Shunt Trip, Undervoltage Trip, Auxiliary Contact
• UL listed Busbars
Circuit Breakers
L-Series(UL489 listed Miniature Molded Case Circuit Breaker)
• Voltage Rating 240VAC (0.2-63A), 480Y/277VAC (0.2-32A), 125VDC (1 pole)/ 250VDC (2 pole) (0.2-63A)
• 10kA Short Circuit Interrupt Capacity
• AC and DC
• C, D Trip Curve
• 1,2,3,4 pole
• Accessories: Add-on Neutral Pole, Shunt Trip, Undervoltage Trip, Auxiliary Contact
• UL listed Busbars
Circuit Breakers
AB-Series(UL489 listed Molded Case Circuit Breaker)
• Interrupting Capacity up to 100kA (240VAC)
• Thermal Magnetic
• Door Interlock Handle
• 3 pole
• Accessories: Auxiliary Switch, Alarm Switch, Shunt/ Undervoltage Trip
Circuit Breakers
UL Standards and its Functions
Standard Function
Circuit Breakers
UL Standards and its Functions
Standard Function
UL1077 Supplementary Protector
Overload Protection
Circuit Breakers
UL Standards and its Functions
Standard Function
UL1077 Supplementary Protector
UL508 Manual Motor Controller
Overload Protection
Overload Protection Switching Function Disconnect Function* *when suitable for disconnect means
Circuit Breakers
UL Standards and its Functions
Standard Function
UL1077 Supplementary Protector
UL508 Manual Motor Controller
UL489 (Miniature) Molded Case Circuit Breaker
Overload Protection
Overload Protection Switching Function Disconnect Function* *when suitable for disconnect means
Overload Protection Switching Function Disconnect Function Short Circuit Protection
Application Example
Circuit Breakers
Typical UL508A Panel
Circuit Breakers
Typical UL508A Panel
Circuit Breakers
Typical UL508A Panel
Circuit Breakers
Typical UL508A Panel
Busbars
Altech’s Busbar Line
• UL508 listed Busbars
• UL489 listed Busbars
Busbars
Distribution Block Busbare.g. #38049 (80A, 1xInput, 6xOutput)
Busbars
Distribution Block Busbar
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
e.g. #38049 (80A, 1xInput, 6xOutput)
Busbars
Distribution Block Busbar
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
e.g. #38049 (80A, 1xInput, 6xOutput) e.g. #P50UT + #3P18U318
Busbars
Distribution Block Busbar
Inputs 80A per Phase
Outputs
80A per
Phase
1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
e.g. #38049 (80A, 1xInput, 6xOutput) e.g. #P50UT + #3P18U318
80A
Busbars
Distribution Block Busbar
Inputs 80A per Phase
Outputs
80A per
Phase
1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
e.g. #38049 (80A, 1xInput, 6xOutput) e.g. #P50UT + #3P18U318
80A
Busbars
Distribution Block Busbar
Inputs 80A per Phase
Outputs
80A per
Phase
1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A80A
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
e.g. #38049 (80A, 1xInput, 6xOutput) e.g. #P50UT + #3P18U318
80A 80A 80A
Busbars
Distribution Block Busbar
Inputs 80A per Phase
Outputs
80A per
Phase
Busbar:
-no wiring between distribution and control device
-Installation-time saving
1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A80A
80A Outputs Phase 1
80A Outputs Phase 1
80A Outputs Phase 1
Input Phase 1
80A
Input Phase 2
80A
Input Phase 3
80A
e.g. #38049 (80A, 1xInput, 6xOutput) e.g. #P50UT + #3P18U318
80A 80A 80A
Busbars
Power Feed (Power Input) Methods (1)
1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A80A
80A 80A 80A
1)Start/End Feed-Method (e.g. with Power Feed Lug P50UT and 18mm² Busbar)
3P18U3/18
Busbars
Power Feed (Power Input) Methods (2)
1 1 1 1 1 1
80A
1 2 3115A
2)Center/Middle Feed-Method (e.g. with Power Feed Lug P50UT and 18mm² Busbar)
35A
3P18U3/18
Busbars
Power Feed (Power Input) Methods (3)
1 2 1 2 1 2 1 2 1 2 1 2
80A80A
1 2 3115A 115A
2)Center/Middle Feed-Method (e.g. with Power Feed Lug P50UT and 18mm² Busbar)
35A35A
3P18U3/18
Busbars
Power Feed (Power Input) Methods (4)
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A80A
1 2 3115A 115A115A
2)Center/Middle Feed-Method (e.g. with Power Feed Lug P50UT and 18mm² Busbar)
35A35A35A
3P18U3/18
Busbars
Power Feed (Power Input) Methods (5)
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
80A80A80A
1 2 3115A 115A115A
2)Center/Middle Feed-Method (e.g. with Power Feed Lug P50UT and 18mm² Busbar)
35A35A35A
35A + 80A = 115A
3P18U3/18
Busbars
Power Feed (Power Input) Methods (6)
2)Center/Middle Feed-Method (e.g. with Power Feed Block P95UB and 25mm² Busbar)
P95UB
Ph
ase
3
Ph
ase
2
Ph
ase
1
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2
3P25U3/18
BRS5
Busbars
Power Feed (Power Input) Methods (6)
1 1 1 1
100A
2)Center/Middle Feed-Method (e.g. with Power Feed Block P95UB and 25mm² Busbar)
100A
200A Input Phase 1
P95UB
3P25U3/18
Busbars
Power Feed (Power Input) Methods (6)
1 2 1 2 1 2 1 2
100A100A
2)Center/Middle Feed-Method (e.g. with Power Feed Block P95UB and 25mm² Busbar)
100A100A
200A Input Phase 1
200A Input Phase 2
P95UB
3P25U3/18
Busbars
Power Feed (Power Input) Methods (7)
1 2 3 1 2 3 1 2 3 1 2 3
100A100A100A
2)Center/Middle Feed-Method (e.g. with Power Feed Block P95UB and 25mm² Busbar)
100A100A100A
200A Input Phase 1
200A Input Phase 3
200A Input Phase 2
P95UB
3P25U3/18
Busbars
UL1077/508 Busbar System (1)
• Electrical Rating: 80A@480VAC (18mm² Pins), 100A@480VAC (25mm² Pins)
• 1,2,3 Phase
• Any possible Pin configuration (1-57Pins)
• ½ pole spacing (auxiliary switch) available
• Power feeding: Power Feed Lugs (115A), Direct Power Feed (80A), Power Feed Block (200A)
• UL508 listed
Busbars
UL1077/508 Busbar System (2)
• Busbars can be cut to customers needs without loosing UL-approval
• UL recognized and listed for Altech’s R-Series, V-EA Series and MA Series of Manual Motor Controllers and Supplementary Protectors
• UL recognized and listed for use with most competitor’s UL1077 supplementary protectors and UL508 Manual Motor Controllers
Busbars
UL489 Busbar System (1)
• Electrical Rating: 80A@480VAC (16mm² Pins)
• 1,2,3 Phase
• 6, 12, 18 Pin configuration
• Power feeding: Power Feed Lugs (115A), Direct Power Feed (80A)
• UL489 listed
Busbars
UL489 Busbar System (2)
• Every Pin configuration possible by combination of existing 6, 12 and 18 Pin Busbars
• UL listed for Altech’s L-Series of Miniature Molded Case Circuit Breaker
• UL listed for use with most competitor’s UL489 Miniature Molded Case Circuit Breaker
Busbars
Configuration of UL489 Busbars (1)
• UL489 Busbars are available in 3 different Pin Configurations per Phase (6, 12 and 18 Pins)
• They can’t be cut, since the creapage and clearance distance requirements from UL are too stringent.
• Therefore to obtain the desired No. of Pins, Busbars can and must be overlapped
Busbars
Configuration of UL489 Busbars (2)1) Busbars are overlapped backwards to each other
Configuration Examples:
1 Phase Busbars 3 Phase Busbars
Busbars
Configuration of UL489 Busbars (3)1) Busbars are overlapped backwards to each other
2) The Number of overlapping Pins of 2 Busbar must be a multiplier of the Number of Phases to keep existing Phase sequence. (Can be overlapped by more than the number of phases)
Configuration Examples:
1 Phase Busbars 3 Phase Busbars
Busbars
Configuration of UL489 Busbars (4)1) Busbars are overlapped backwards to each other
2) The Number of overlapping Pins of 2 Busbar must be a multiplier of the Number of Phases to keep existing Phase sequence. (Can be overlapped by more than the number of phases)
3) Any available combination of the 3 different Pin configurations is possible
Configuration Examples:
1 Phase Busbars 3 Phase Busbars
Thank You!!