sd050

1
COLUMN TAILPIPE RAFTER HAUNCH HIGH LEVEL COLLECTION MAIN (REFER TO SD080) CONTINUOUS RAIL SYSTEM INTERMEDIATE HANGER ANGLE CLEAT (REFER TO FULLFLOW FOR LOADINGS) (REFER TO SD081) 6) FOR DIMENSIONED DETAILS OF FULLFLOW OUTLETS REFER TO SD001 TO SD016 ADDITIONAL BRACKETRY WILL BE TAIL - PIPE IS 1.5 METRES OR LONGER, OFF - SETTING AROUND ANY BEAMS, 5) IF THE HORIZONTAL SECTION OF THE FOR WHICH REFER TO SD053. 4) NO PROVISION HAS BEEN MADE FOR 2) DIMENSIONS SUBJECT TO 3) THIS DRAWING IS COMPUTER ON 3.5", CD ROM AND E- MAIL IN AUTOCAD AND .DXF FORMAT. MANUFACTURING TOLERANCES. 1) DO NOT SCALE FROM THIS DRAWING GENERATED COPIES ARE AVAILABLE USE FIGURED DIMENSIONS ONLY. This drawing is the property of FULLFLOW LIMITED and must not be used, loaned, reproduced or disclosed in whole or in part to third parties without the company's written permission. Tel:- +44 (0) 1142 473655 Fax:- +44 (0) 1142 477805 Fullflow House, Holbrook Avenue, Holbrook TYPICAL EAVES DETAIL (PRIMARY ONLY) TYPICAL EAVES DETAIL (PRIMARY ONLY) Title: Rev. No. Email:- [email protected] Sheffield, S20 3FF RAINWATER MANAGEMENT Date Description REQUIRED. NOTES Drawing No: Cad Ref: Rev: Date: Drn By: App. By: Chkd By: Scales: Chkd. Drn. By By By App. NTS SE October/2000 SD050 SD050 0 DB MB

description

sd050

Transcript of sd050

  • CO

    LUM

    N

    TAILPIPE

    RAFTER

    HAUNCH

    HIGH LEVEL COLLECTION MAIN

    (REFER TO SD080)CONTINUOUS RAIL SYSTEM

    INTERMEDIATE HANGER

    ANGLE CLEAT

    (REFER TO FULLFLOW FOR LOADINGS)

    (REFER TO SD081)6) FOR DIMENSIONED DETAILS OFFULLFLOW OUTLETS REFER TOSD001 TO SD016

    ADDITIONAL BRACKETRY WILL BETAIL - PIPE IS 1.5 METRES OR LONGER,

    OFF - SETTING AROUND ANY BEAMS,

    5) IF THE HORIZONTAL SECTION OF THEFOR WHICH REFER TO SD053.

    4) NO PROVISION HAS BEEN MADE FOR

    2) DIMENSIONS SUBJECT TO

    3) THIS DRAWING IS COMPUTER

    ON 3.5", CD ROM AND E- MAIL INAUTOCAD AND .DXF FORMAT.

    MANUFACTURING TOLERANCES.

    1) DO NOT SCALE FROM THIS DRAWING

    GENERATED COPIES ARE AVAILABLE

    USE FIGURED DIMENSIONS ONLY.

    This drawing is the property of FULLFLOW LIMITED and must not be used, loaned, reproducedor disclosed in whole or in part to third parties without the company's written permission.

    Tel:- +44 (0) 1142 473655 Fax:- +44 (0) 1142 477805

    Fullflow House, Holbrook Avenue, Holbrook

    TYPICAL EAVES DETAIL (PRIMARY ONLY)

    TYPICAL EAVES DETAIL (PRIMARY ONLY)

    Title:

    Rev.No.

    Email:- [email protected]

    Sheffield, S20 3FF

    RAINWATER MANAGEMENT

    Date Description

    REQUIRED.

    NOTES

    Drawing No:

    Cad Ref:

    Rev:

    Date:

    Drn By:

    App. By:

    Chkd By:

    Scales:

    Chkd.Drn.By By By

    App.

    NTS

    SE

    October/2000

    SD050

    SD050

    0

    DBMB