Sample Report

22
Notice To Third Parties: This report is the exclusive property of Cardinal Home Inspection and the client(s) listed above and is not transferable to any third parties or subsequent buyers. Our inspection and this Report have been performed with a written contract agreement that limits its scope and usefulness. Unauthorized recipients are therefore advised not to rely on this Report, but rather to retain the services of a qualified home inspector of their choice to provide them with their own inspection and report. Cardinal Home Inspection Confidential - Property Inspection Report - Confidential Cover Page 12345 Somewhere Road, Anytown VA, 34567 Inspection prepared for: Bob & Susan Sample Agent: Support - Home Inspector Pro Inspection Date: 7/4/2009 Age: 21 Size: 2000 Weather: Clear Inspector: Mark Burnett ASHI #246966 www.cardinalhomeinspect.com

description

Sample report for website

Transcript of Sample Report

Notice To Third Parties: This report is the exclusive property of Cardinal Home Inspection and the client(s) listed above and isnot transferable to any third parties or subsequent buyers. Our inspection and this Report have been performed with a writtencontract agreement that limits its scope and usefulness. Unauthorized recipients are therefore advised not to rely on this Report,but rather to retain the services of a qualified home inspector of their choice to provide them with their own inspection and report.

Cardinal Home InspectionConfidential - Property Inspection Report - Confidential

Cover Page

12345 Somewhere Road, Anytown VA, 34567Inspection prepared for: Bob & Susan Sample

Agent: Support - Home Inspector Pro

Inspection Date: 7/4/2009 Age: 21 Size: 2000

Weather: Clear

Inspector: Mark BurnettASHI #246966

www.cardinalhomeinspect.com

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 1 of 21

Inspection and Site Details

1. Inspection TimeStart: 12:00 PM End : 3:00 PM

2. Attending InspectionClient presentBuyer Agent present

3. Residence Type/StyleSingle Family Home

4. Age of Home or Year Built1989 (20 years old)

5. Square Footage2000 sq ft

6. Front of Home FacesThe home faces: South

7. Bedrooms and BathroomsNumber of Bedrooms: 3Number of Bathrooms: 2

8. OccupancyVacant

9. Temperature80 degrees

10. Weather ConditionsClear, sunny sky

11. Ground/Soil Surface ConditionDry

12. Rain in the Last Three DaysNo

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 2 of 21

Conventions and Terms Used in this Report Conventions, terms, and definitions utilized throughout this Property Inspection Report  TEXT COLOR SIGNIFICANCE: GREEN text: Denotes general/descriptive comments on the systems and components installed at the property. May alsoinclude limitations, if any, associated with each area of inspection. BLUE text: Denotes observations and information regarding the condition of the systems and components of the home.These include comments of deficiencies which are less than significant; comments which further expand on a significantdeficiency; or recommendations, routine maintenance, and other information. RED text: Denotes comments on significant deficient systems and components or conditions whichneed relatively quick attention, repair, or replacement. RED comments are duplicated in the ReportSummary page(s). Definitions of key words used in "OBSERVATIONS:" "INSPECTED": The item, system, or component was visually inspected—and if no other comment ismade, then it was functioning properly as intended, with no deficiencies noted—allowing for normalwear and tear. "NOT INSPECTED": The item, system, or component was not visually inspected and the inspectormakes no representation of whether or not it was functioning properly and will state a reason for notinspecting it. "NOT PRESENT": The item, system, or component is not in this home or building. "DEFICIENT": The item, system, or component was inoperative, showed material distress, waterpenetration, damage, deterioration, missing parts, or was not suitably installed. It may include acondition that is hazardous or unsafe and could result in personal injury or property damage. "REPAIR AS NEEDED": The item, system, or component is recommended to be repaired orreplaced, as required. It may need further review and evaluation by an appropriate professionaltradesperson. "SAFETY CONCERN": A condition, system or component that is considered harmful or dangerousdue its presence or absence. "DEFERRED COST": Denotes a system or component that is near or has reached its normal servicelife expectancy or shows indications that it may require replacement anytime within the next 5 years. "MAINTENANCE": Denotes recommendations for the proper operation and routine maintenance ofthe home. "IMPROVE": Denotes improvements which are recommended but not required and are at thediscretion of the Client. These may be items identified for upgrade to modern construction and safetystandards. "FYI": These are items that are noted for your information and provide you with a generalexplanation of conditions, safety information, cosmetic issues, and useful tips or suggestions forhome ownership. May also include web links to sites with additional/expanded reference materialand important consumer product information.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 3 of 21

    7/4/2009 Dear Bob and Susan Sample: Thank you for choosing Cardinal Home Inspection to perform your home inspection. The goal of this inspection is toreduce some of the risk involved in your real estate transaction by putting you in a better position to make informeddecisions concerning this property. However, it will not eliminate all the risk—for this reason, a home inspection shouldnot be considered an insurance policy. This inspection and the report is a general guide and provides you with someobjective information to help you make your own evaluation of the overall condition of the home. It is not intended toreflect the value of the property, or to make any representation as to the advisability of purchase. This is not anexhaustive inspection of the structure, systems, or components—all deficiencies may not be identified. Unexpectedrepairs should still be anticipated. This inspection is not a guarantee or warranty of any kind. Cardinal Home Inspection perform all inspections in substantial compliance with the Standards of Practice of theAmerican Society of Home Inspectors® (ASHI). As such, I inspect the readily accessible, visually observable, installedsystems and components of a home as designated in the ASHI® Standards—except as may be noted in the “Limitationsof Inspection” sections within this report. This inspection report contains observations of those systems and componentsthat, in my professional judgment, are not functioning properly, significantly deficient, unsafe, or are near the end of theirservice life. If the cause for the deficiency is not readily apparent, the suspected cause or reason why the system orcomponent is at or near end of expected service life is reported, and recommendations for correction or monitoring aremade as appropriate. When systems or components designated in the ASHI® Standards are present but are notinspected, the reason(s) the item was not inspected is reported as well. A copy of the ASHI® Standards of Practice is available at: www.homeinspector.org/docs/standards.pdf These standardsdefine the scope of a home inspection. Clients sometimes assume that a home inspection will include many things thatare beyond the scope. I encourage you to read the ASHI Standards of Practice so that you clearly understand whatthings are included in the home inspection and report. This report is effectively a snapshot of the house—recording theconditions on a given date and time. Home inspectors cannot predict future behavior, and as such, I cannot beresponsible for things that occur after the inspection. If conditions change, I am available to revisit the property andupdate my report. This report was prepared for your exclusive use, as our client. No use by third parties is intended. Cardinal HomeInspection will not be responsible to any parties for the contents of the report, other than the party named herein. Thereport itself is copyrighted, and may not be used in whole or in part without Cardinal Home Inspection's express writtenpermission. Again, thanks very much for the opportunity of conducting this inspection for you. I am available to you throughout yourentire real estate transaction process. Should you have any questions, please call or email. Sincerely, Mark Burnett, ASHI Inspector #246966Cardinal Home [email protected]

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 4 of 21

Exterior Exterior grading and drainage are probably the most significant aspects of a property, simplybecause of the direct and indirect damage that moisture can have on a property. More damageresults from moisture and expansive soils than from most natural disasters. All gutters anddownspouts should discharge away from the property, Downspouts should not be allowed toterminate over paved areas such as walks and driveways, as this can contribute to ice and winterhazards. Vegetation too close to the property can contribute to root damage to the foundation, abrasion of roofand siding, and leave a potential for moisture and insects to enter the property. We recommend thatall vegetation be kept 18” from the foundation and siding, All branches should be 5 –6 feet from theroof and monitored regularly. Open window wells should have a properly installed cover to prevent rain and snow fromaccumulating inside the well and possibly leaking into the property.

1. DrivewayMaterials: GravelObservations:• Appeared functional and satisfactory, at time of inspection.• No deficiencies noted at the time of the inspection.

2. WalkwaysMaterials: Brick/PaversObservations:• Appeared functional and satisfactory, at time of inspection.• No deficiencies noted

3. Exterior DoorsDescription:• Front entry door: Metal• Rear entry door: French-style, fiberglassObservations:• Appeared in functional and in satisfactory condition, at time of inspection.• Hardware is damaged/missing at front entry door. Repair as needed.

4. Exterior CladdingDescription: Wood SidingObservations:• Exterior cladding appeared in serviceable condition, with no deficiencies noted

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 5 of 21

Siding split, recommend replacement

5. Eaves, Soffits, FasciasDescription: Wood

6. Deck, BalconyDescription: WoodObservations:• Appears in satisfactory and functional condition with normal wear for its age. Appears to be in sound structure.

7. Grading, Surface DrainageDescription: Ground generally graded away from houseObservations:• No deficiencies noted.

8. Vegetation Affecting StructureDescription: Vegetation in contact with the house.Observations:• Recommend having vegetation trimmed, pruned, or removed from affected areas, and regular homeowner monitoring andlandscaping maintenance thereafter.

Shrubs too close to structure

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 6 of 21

9. Limitations of Exterior Inspection

• While performance of lot drainage and water handling systems may appear serviceable at the time of inspection, theinspector cannot always accurately predict this performance as conditions constantly change. Furthermore, items such asleakage in downspout/gutter systems are very difficult to detect during dry weather. Inspection of foundation performanceand water handling systems, therefore, is limited to visible conditions and evidence of past problems.• Exterior above/below-ground swimming pools are beyond the scope of a home inspection.• A home inspection does not include an assessment of geological, geotechnical, or hydrological conditions -- or environmentalhazards.• Awnings, or similar seasonal accessories, recreational facilities, outbuildings, water features, hot tubs, statuary, pottery, firepits, patio fans, heat lamps, and decorative low-voltage landscape lighting are not inspected unless specifically agreed uponand documented in this report.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 7 of 21

Roofing As with all areas of the property we recommend that you carefully examine the roof immediately prior to closing the deal.Please be advised that walking on a roof voids some manufacturer’s warranties. Adequate attic ventilation, solar / windexposure, and organic debris will affect the life expectancy of a roof. If purchasing a property always ask the seller aboutthe age and history of the roof. On any home that is over 3 years old, experts recommend that you obtain a roofcertification from an established local roofing company to determine its serviceability.

1. Roof Style and PitchGabled

2. Method of Roof InspectionWalked on Roof Surface

3. Roof CoveringMaterials: Asphalt-based three tab shinglesAge: 15-20+ yearsObservations:• These shingles appear to be in the last third of their life cycle.• FYI: Once a roof reaches the ten (10) year mark, it is a good idea to have the roof inspected for any signs of aging every threeyears. A roof that has some routine maintenance in its second half of life will outperform those that are not maintained.• Though no evidence of leakage was noted at the time of the inspection, it is recommended that annual monitoring of the roofcovering and its' condition be administered.• Missing/torn shingles across roof surface. Recommend replacement where appropriate to prevent moisture damage tostructure.• Loss of the shingles' surface granulation was observed. This is common with aging of the roof covering.

Missing shingle, recommend replacement Missing shingle, recommend replacement

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 8 of 21

exposed fastener, recommend replacement

4. FlashingsMaterials: MetalObservations:• Visible areas appeared functional, at time of inspection

5. Roof PenetrationsDescription: PVC Piping for plumbing vent stack(s)Observations:• Plumbing vent stack flashing boot(s) appeared functional.• Base of plumbing vent stack flashing boot(s) are rusted. Recommend applying a rust inhibitive to curtail the rusting.

Base of vent boot exhibiting signs of surface rust

6. Chimney(s)Description: Masonry -- for wood burning fireplace with terracotta flueObservations:• The chimney crown is cracked or damaged. Further deterioration and expensive repairs may occur. Recommend a chimneymason/specialist repair or replace the damaged crown.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 9 of 21

7. Roof Drainage SystemDescription: All downspouts discharge below grade--connected to in-ground drainage pipingObservations:• MAINTENANCE: Routinely monitor to keep gutters and gutter screens from clogging. A good time to check for proper guttersystem operation is during a rainfall -- walk the perimeter of the house. Clean and seal gutters as needed.• Areas of gutters clogged. Recommend routine maintenance to prevent problem.

8. Limitations of Roofing Inspection

• It highly recommended to ask the seller about the age & history of the roof and obtain roof documentation (if available).• Roofs may leak at any time. Leaks often appear at roof penetrations, flashings, changes in direction or changes in material. Aroof leak should be addressed promptly to avoid damage to the structure, interior finishes and furnishings. A roof leak doesnot necessarily mean the roof has to be replaced. We recommend an annual inspection and tune-up to minimize the risk ofleakage and to maximize roof life.• Impossible to inspect the total underside surface of the roof sheathing for evidence of leaks. Evidence of prior leaks may bedisguised by interior finishes. Leakage can develop at any time and may depend on rain intensity, wind direction, ice buildup,and other factors.• Estimates of remaining roof life are approximations only and do not preclude the possibility of leakage.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 10 of 21

Structural Components In accordance with the ASHI© Standards of Practice pertaining to Structural Components, this report describes thefoundation, floor, wall, ceiling and roof structures and the method used to inspect any accessible under floor crawlspaceareas. Inspectors are required to inspect and probe the structural components of the home, including the foundation andframing, where deterioration is suspected or where clear indications of possible deterioration exist. Probing is not donewhen doing so will damage finished surfaces or when no deterioration is visible or presumed to exist. Inspectors are NOTrequired to offer an opinion as to the structural adequacy of any structural systems or components or providearchitectural services or an engineering or structural analysis of any kind. Despite all efforts, it is impossible for a homeinspection to provide any guaranty that the foundation, and the overall structure and structural elements of the building issound. Cardinal Home Inspection suggests that if the client is at all uncomfortable with this condition or ourassessment, a structural engineer be consulted to independently evaluate any specific concern or condition, prior tomaking a final purchase decision.

1. Foundation TypeCrawlspace

2. Foundation WallsDescription: Cinder Block

3. Foundation FloorDescription: Crawl Space: earthen/dirt floorObservations:• Moisture present in areas at the time of inspection.

4. Under Floor Crawlspace(s)Method of Inspection: Accessed and crawledInsulation & Ventilation:• Under floor insulation type: fiberglass batts• Soil vapor barrier: polyethylene plastic• Shuttered/louvered vents located around foundation perimeter.Observations:• The vapor barrier (plastic) on the crawlspace floor iis missing and deteriorated in areas of the crawlspace. A vapor barrierprovides added protection to the floor system from moisture or dampness that can enter from ground. A qualified contractorshould repair/replace as needed.

5. Columns, BeamsDescription: Wood beam and piersObservations:• No deficiencies noted at the visible areas.

6. Floor StructureDescription: 2 X 10 dimensional lumber wood joists • Plywood sheathing sub floorObservations:• No deficiencies noted at the time of the inspection.

7. Wall StructureDescription: Wood frame: 2 X 4 dimensional lumberObservations:• No visible deficiencies noted.

8. Ceiling, Roof StructureDescription: Engineered wood roof truss framing • Plywood SheathingObservations:• No deficiencies noted at the time of the inspection.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 11 of 21

9. Limitations of Structural Components Inspection

• Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity of any structuralsystem or component are not part of a home inspection.• Full inspection of all structural components (posts/girders, foundation walls, sub flooring, and/or framing) is not possible inareas/rooms where there are finished walls, ceilings and floors.• A representative sample of the visible structural components was inspected.• No representation can be made to future leaking of foundation walls.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 12 of 21

Attic and Insulation We recommend that all attic hatches have a batt of fiberglass insulation installed over them, and the hatch be sealedshut with latex caulk. This will keep warm moist air from entering the attic, which may cause condensation or even mold.Note that every attic has mold; mold is everywhere. This is often a result of the building process, when materials get wetduring construction. Due to the nature of attics and the potential for damage you inspector will not attempt to enter anattic that has no permanently installed steps or pull down stairs, has less than 36” of headroom, is restricted by ducts, nostandard floor for normal walking. Walking in an attic without a proper designed floor may compromise the ceiling below.In these cases you inspector will observe the attic as best they can from the access point, with no comments orevaluations of areas not readily viewed from the hatch area.

1. Attic AccessAttic Inspection Method: Viewed and walked in the AtticPull Down Ladder located in:Hallway ceilingAttic light installed just inside access

2. Attic VentilationDescription: Passive ventilation • Under eave soffit inlet vents • Gable louver ventsObservations:• No deficiencies noted.• Attic should be reviewed at least twice per year to ensure ventilation openings are clear and to ensure development of mold iskept in check. While there may be very little or no evidence of mold buildup in the attic at time of inspection, it can reproduceand spread rapidly should conditions allow it to. Mold can be potentially hazardous and will spreadwhen moisture enters the attic cavity and is not adequately vented to the exterior. Any area of suspected mold should bereviewed by a qualified contractor for analysis and removal.

3. Insulation in Unfinished SpacesDescription: Attic Insulation:Fiberglass, loose fillFiberglass, battsDepth/R-Value: Approximately:7-10 inchesObservations:• Insulation level in the attic is typical for homes this age• Visible insulation appears adequate.

4. Vent Piping Through AtticDescription: PVC plumbing ventsObservations:• No deficiencies noted on visible sections (reference Observation in Roofing Section) .

5. Limitations of Attic and Insulation Inspection

• Insulation/ventilation type and levels in concealed areas, like exterior walls, are not inspected.• Insulation and vapor barriers are not disturbed and no destructive tests (such as cutting openings in walls to look forinsulation) are performed.• An analysis of indoor air quality is not part of this inspection unless explicitly contracted-for seperately.• Any estimates of insulation R values or depths are rough average values.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 13 of 21

Electrical In accordance with the ASHI© Standards of Practice pertaining to Electrical Systems, this report describes the amperageand voltage rating of the service, the location of the main disconnect and any sub panel(s), the presence of solidconductor aluminum branch circuit wiring, the presence or absence of smoke detectors and wiring methods. Inspectorsare required to inspect the viewable portions of the service drop from the utility to the house, the service entranceconductors, cables and raceways, the service equipment and main disconnects, the service grounding, the interiorcomponents of the service panels and sub panels, the conductors, the over-current protection devices (fuses orbreakers), ground fault circuit interrupters and a representative number of installed lighting fixtures, switches andreceptacles. All issues or concerns listed in this Electrical section should be construed as current and a potentialpersonal safety or fire hazard. Repairs should be a priority, and should be made by a qualified, licensedelectrician.

1. Service DropDescription: Underground service lateral, Meter Location: rear of homeObservations:• No deficiencies noted.

2. Service Entrance ConductorsDescription:• Aluminum• 4/0 AWG wireObservations:• No deficiencies noted.

3. Service RatingAmperage Rating: 200 amps

4. Main DisconnectDescription: One 200 Amp Breaker on Main Service Panel. See photo below.

5. Main Service Panel(s)Description: Manufacturer: Seimens, breaker-styleObservations:• The wiring within the panel appeared satisfactory - no deficiencies.• There are few panel screws missing off the panel cover. This is a potential fire hazard. FYI: Screws are specific to the panel.They must fit a 'Seimens' brand panel.

6. Sub Panel(s)Description: Panel Rating: 125 amp, 120/240 volt • Located in family room • Breakers in Use • Manufacturer: Cutler-HammerObservations:• The auxiliary panel ground & neutral wires are properly un-bonded.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 14 of 21

7. Service GroundingDescription:• Copper• Outside- back of residence• Ground Rod ConnectionObservations:•

No deficiencies noted at the time of the inspection.

8. Overcurrent ProtectionType: BreakersObservations:• No deficiencies noted.

9. Wiring MethodsDescription: Copper • Wiring type: non-metallic sheathed cable "Romex"Observations:• Visible wiring appeared functional no discrepancies noted.

10. Lighting, Fixtures, Switches, OutletsDescription: GroundedObservations:• A representative sampling of outlets, switches and light fixtures were tested. No deficiencies noted.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 15 of 21

11. GFCIDefinition: Ground Fault Circuit Interrupter - GFCI - is an electrical safety device that cuts power to an individual outletand/or entire circuit when as little as .005 amps is detected leaking--this is faster than a person's nervous system can react!Kitchens, bathrooms. whirlpools/hot-tubs, unfinished basements, garages, and exterior circuits are normally GFCI protected.This protection is from electrical shock.Present at:• Present at:• Bathrooms• Kitchen• ExteriorObservations:• For your protection -- all kitchen outlets/receptacles accessible from the counter top are now required to be GFCI protected.

12. AFCILocations & Resets: None FoundObservations:• There is no AFCI protection.• All bedroom circuits are now required to be AFCI protected.

13. Smoke/Heat Detector(s)Description: Present throughout homeObservations:• Operated when tested• MAINTENANCE: Periodic testing and changing batteries yearly to ensure proper Smoke Alarm operation is required.

14. Limitations of Electrical Inspection

• Electrical components concealed behind finished surfaces are not visible to be inspected.• Labeling of electric circuit locations on Main Electrical Panel are not checked for accuracy.• Only a representative sampling of outlets, switches and light fixtures were tested.• The inspection does not include remote control devices, alarm systems and components, low voltage wiring, systems, andcomponents, ancillary wiring, systems, and other components which are not part of the primary electrical power distributionsystem.• A low voltage alarm system is installed. Due to the specialized nature of these systems, we suggest that you review thissystem with the seller. As per our Inspection Agreement, this system is beyond the scope of this report and was not inspected.• Due to the specialized nature of home security alarm systems, recommend you review this system with the seller. Securitysystems are beyond the scope of a home inspection.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 16 of 21

Plumbing In accordance with the ASHI© Standards of Practice pertaining to Plumbing systems, this report describes the watersupply, drain, waste and vent piping materials and the water heating equipment, energy source and location of the mainwater and main fuel shut-off valves, when readily viewable or known. Inspectors are required to inspect the interior watersupply and distribution systems, all fixtures and faucets, the drain waste and vent systems (including all fixtures forconveying waste), the water heating equipment (vent systems, flues and chimneys of water heaters or boiler equipment),fuel storage and distributions systems for water heaters and/or boiler equipment and drainage sumps, sump pumps andassociated piping. Some simple plumbing repairs, such as a typical trap replacement, can be performed by a competenthandyman. However, any more complex issues such as incorrect venting or improperly sloped drains should be repairedby a licensed plumber. All gas related issues should only be repaired by a licensed plumbing contractor —since personalsafety is involved.

1. Water SupplySource: Private well water supply

2. Main Service PipingMaterials: Plastic

3. Main Water Shut OffLocation:• Crawlspace• Front wall of crawlspace.Observations:• Located, tagged and client made aware of.

4. Exterior Hose Bibs/SpigotsDescription: Standard, frost-proof hose bib(s) at side, and rear of home.Observations:• Missing handle at rear hose bib. Recommend replacement for easier operation.

5. Water Supply, Distribution SystemsDescription: Readily visible water supply pipes are:CopperObservations:• No deficiencies observed at the visible portions of the supply piping.

6. FaucetsObservations:• No deficiencies noted.

7. SinksObservations:• No deficiencies observed.

8. Flow and PressureObservations:• The water pressure and flow was functional at the time of inspection.

9. Waste, Drain, Vent PipingWaste System Type: Private sewage disposal - Septic - systemObservations:• Visible piping appeared serviceable at time of inspection.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 17 of 21

10. Water Heater(s)Manufacturer:• State• Electric• Location: Laundry roomCapacity: 80 Gallons

11. Water Heater(s) ConditionAge: 3 YearsObservations:• No deficiencies noted with the Temperature Pressure Relief (TPR) valve and discharge pipe.

12. Limitations of Plumbing Inspection

• The sections of the plumbing system concealed by finishes and/or storage (below sinks, etc.), below the structure, orbeneath the ground surface are not inspected.

• I did not inspect the condition of all the faucets, fixtures, plumbing traps and water flow. Inspection cut short at client'sdirection. There is an additional charge for a separate trip to return and inspect these items.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 18 of 21

Bathrooms Bathrooms can consist of many features from whirlpool tubs and showers to toilets and bidets. Because of all theplumbing involved it is included here as a separate area. Fixtures and faucets, functional water flow, leaks, and crossconnections are checked. Moisture in the air, water leaks, and deteriorated/poor caulking and grouting can cause mildew,wallpaper/paint to peel, and other problems. The inspector will identify as many issues as possible but some problemsmay be undetectable within the walls or under flooring. It is important to routinely maintain all bathroom grouting andcaulking, because minor imperfections will result in water intrusion and unseen damage behind surfaces.

1. Bathroom # Designation - for the purposes of this reportMasterHall

2. Tub(s)Description: Plastic/FiberglassObservations:• Appeared satisfactory and functional, at time of inspection.

3. Toilet(s)Observations:• Operated when tested. No deficiencies noted.

4. Bathroom Exhaust Fan(s)Observations:• Operated when tested.• Bathroom fans exhaust to exterior at soffits

5. A Word About Caulking and Bathrooms

• Areas which should be examined periodically are vertical corners, horizontal corners/grout lines between walls andtubs/shower pans and at walls near floor areas. Also, the underside of shower curbs, the tub lip, tub spouts, faucet trim platesand any other areas mentioned in this report.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 19 of 21

Interior In accordance with the ASHI© Standards of Practice pertaining to Interiors, inspectors are required to inspect walls,ceilings and floors, steps, stairways and railings, installed countertops and a representative number of installed cabinets,and representative number of doors and windows. Garage door(s) and automatic garage door operators are inspectedfor proper function and the operation of installed safety features. If the home is occupied, the possessions of the ownernecessarily conceal some areas/items. These are exempt from inspection. All reasonable attempt is made to moreclosely inspect behind the owner's possessions if any hint of a problem is found or suspected.

1. Door BellObservations:• Operated normally when tested.

2. Wall and Ceiling FinishesMaterials: DrywallObservations:• The ceiling drywall in the living room and hallway has some "nail pops". This is a cosmetic issue.

3. Floor FinishesMaterials: Hardwood type • CarpetObservations:• Normal wear and tear for the age of the coverings was observed.

4. WindowsDescription: Wood, VinylObservations:• All windows were operated and were functional.

5. Interior DoorsDescription: Hollow core wood doorsObservations:• Doors were tested and functional, at the time of the inspection.• Missing latch on the pocket door located in the master bathroom.

6. Limitations of Interior Inspection

• There were a moderate amount of personal/household items in each room. Furniture, storage, appliances and/or wallhangings are not moved to permit inspection and may block defects.• Recommend thorough review of interior areas during final walk-through inspection prior to closing.• Window treatments, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 20 of 21

Appliances Inspector observed and operated the basic functions of the following appliances: Permanently installed dishwasher(s),through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Kitchenventilation or range hood; Permanently installed microwave oven; and Conveying laundry appliances. Interiorrefrigerator/freezer temperatures are not tested. Inspection of stand-alone freezers and secondary refrigerators areoutside the scope of this inspection. No opinion is offered as to the cleaning adequacy of dishwashers. Oven self orcontinuous cleaning operations, cooking functions, clocks, timing devices, lights and thermostat accuracy are not testedduring this inspection. Appliances are not moved and the condition of any walls or flooring hidden by them cannot bejudged.

1. DishwasherBrand: KenmoreObservations:• Operated through one cycle and appeared to be in working order at time of inspection.

2. Garbage DisposalBrand: InSinkEratorObservations:• Operated - appeared functional at time of inspection.

3. Ranges, Ovens, CooktopsBrand:• Kenmore• Electric

4. Kitchen Hood/Exhaust FanBrand: BroanObservations:• Functioned and operated normally when tested.• Filter is dirty/Clean or replace

5. RefrigeratorDescription: FrigadaireObservations:• Appeared functional, at time of inspection.

6. WasherDescription: FrigidaireObservations:• The washer was not tested. This is out of the scope of the inspection.

7. DryerDescription: Frigadaire

8. Dryer VentObservations:• Proper installation of the dryer vent and pipe was observed.• Properly vented to exterior.

Cardinal Home Inspection 12345 Somewhere Road, Anytown, VA

Page 21 of 21

Report Summary

Report Summary

IMPORTANT NOTE: This page reflects a brief summary of the significant deficiencies or critical concerns which areimportant to highlight as they relate to function or safety. This is only a summary and is provided as a courtesy— itshould not be considered to be the complete report. The complete list of issues, concerns, deficiencies and importantdetails pertaining to this property is found throughout the body of the inspection report. Your entire report must becarefully read to fully assess all of the findings and benefit from the recommendations, maintenance advice, tips andother important resource information.

ExteriorPage 4 Item: 3 Exterior Doors • Hardware is damaged/missing at front entry door. Repair as needed.

RoofingPage 8 Item: 3 Roof Covering • Missing/torn shingles across roof surface. Recommend replacement where

appropriate to prevent moisture damage to structure.• Loss of the shingles' surface granulation was observed. This is common withaging of the roof covering.

Page 8 Item: 6 Chimney(s) • The chimney crown is cracked or damaged. Further deterioration andexpensive repairs may occur. Recommend a chimney mason/specialist repair orreplace the damaged crown.