Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2015 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360 LED Snap | Linear, Surface INSTALLATION INSTRUCTIONS WARNING: Ground fixture in according with local and national electrical codes. Failure to do so may result in serious personal injury. 01-05-2017 Removing Lens 1. Start at the end of fixture. Place both thumbs on edge of end plate or center plate of 8’ fixture. Place fingers on top of edge of lens. Simultaneously pull lens outward and down with all fingers. (See figure 1). 2. Remove ballast cover to access ballast wires. Pull out end cap/ intermediate cap for installation of fixtures. 3. Make all wire connections and replace all reflectors. Snap all lens, onto houses. Replacing Lens 4. Start at end of fixture, angle lens slightly downwards. Place both lens tracks onto housing edge working towards angled end. Lens should snap onto fixture (See figure 2). NOTE: When surface/wall mounting, allow space around fixture to access lamp. (Mounting hardware by others - see figure 3). 1. Attach cable onto far end of next fixture in row. Lift fixture and cable and attach to support hardware on ceiling surface. Lift opposite end of fixture to first (Hanging) fixture. Connect all necessary wires. Insert joiner assy into (Hanging) fixture and fasten top coupler plate. FIXTURE MOUNTING CONTINUOS ROW INDIVIDUAL/ CONTINUOS ROW MOUNTING PLAN Fixture Length Dim A. Cable Mount Dim B Surface Mount Dim C. K.O. Location Dim D. 2’ 23˝ 19˝ One Side Only 3’ 35˝ 31˝ 29˝ 4’ 47˝ 43˝ 41˝ 6’ 71˝ 67˝ 65˝ 8’ 95˝ 91˝ 89˝ FIGURE 1 CROSS SECTION CABLE MOUNTING FIGURE 2 FIGURE 3 Driver LED Cover Optional TRS End Plate LED Lens 31/8˝ 27/16˝ Reference instruction #’s 42100 & 42101 for cable installation Use Romex clamp (by others) for SJT cord Top Coupler Plate Joiner Assy 2 3/8˝ typ. 3 ˝ typ. 7/8˝ Power Feed K.O. 5/16˝ Surface Mounting Holes Dim A. Dim B. Dim C. Dim D. ˝

Transcript of S Linear, Surface

Page 1: S Linear, Surface

Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2015 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058

PRULITE.COM 213.746.0360

LED Snap | Linear, SurfaceI N S T A L L A T I O N I N S T R U C T I O N S

WARNING: Ground fixture in according with local and national electrical codes. Failure to do so may result in serious personal injury.

01-05-2017

Removing Lens

1. Start at the end of fixture. Place both thumbs on edge of end plate or center plate of 8’ fixture. Place fingers on top of edge of lens. Simultaneously pull lens outward and down with all fingers. (See figure 1).

2. Remove ballast cover to access ballast wires. Pull out end cap/ intermediate cap for installation of fixtures.

3. Make all wire connections and replace all reflectors. Snap all lens, onto houses.

Replacing Lens

4. Start at end of fixture, angle lens slightly downwards. Place both lens tracks onto housing edge working towards angled end. Lens should snap onto fixture (See figure 2).

NOTE: When surface/wall mounting, allow space around fixture to access lamp. (Mounting hardware by others - see figure 3).

1. Attach cable onto far end of next fixture in row. Lift fixture and cable and attach to support hardware on ceiling surface. Lift opposite end of fixture to first (Hanging) fixture. Connect all necessary wires. Insert joiner assy into (Hanging) fixture and fasten top coupler plate.

F I X T U R E M O U N T I N G

C O N T I N U O S R O W

I N D I V I D U A L / C O N T I N U O S R O W M O U N T I N G P L A NFixture Length

Dim A.Cable Mount

Dim BSurface Mount

Dim C.K.O. Location

Dim D.

2’ 231/2˝ 191/4˝ One Side Only

3’ 351/2˝ 311/4˝ 291/2˝

4’ 471/2˝ 431/4˝ 411/2˝

6’ 711/2˝ 671/4˝ 651/2˝

8’ 951/2˝ 911/4˝ 891/2˝

FIGURE 1 CROSS SECTION

CABLE MOUNTING

FIGURE 2

FIGURE 3

Driver

LED Cover

Optional TRS

End Plate

LED

Lens

31/8˝

27/16˝

Reference instruction #’s 42100 & 42101 for cable installation

Use Romex clamp (by others) for SJT cordTop Coupler

Plate

Joiner Assy

2 3/8̋ typ.3 1/4 ̋typ. ∅ 7/8̋ Power Feed K.O. ∅ 5/16̋ Surface Mounting Holes

Dim A.

Dim B.

Dim C.

Dim D.1/4˝

Page 2: S Linear, Surface

Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2015 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058

PRULITE.COM 213.746.0360

LED Snap | Linear, SurfaceI N S T A L L A T I O N I N S T R U C T I O N S

WARNING: Ground fixture in according with local and national electrical codes. Failure to do so may result in serious personal injury.

01-05-2017

E B C P - E L E C T R I C A L B O X C O V E R S ( O P T I O N A L )

J-Box (By others)

Wall cutout to clear fixture mounting hole

Fixture mounting

hole

Mounting screw (By others)

J-Box (By others)

Screws (By others)

2˝x 4˝ Cover

4˝x 4˝ Cover

OPTIONAL ELECTRICAL BOX COVERS7/8˝ Dia. K.O. will accomodate2˝x 4˝ or 4˝x 4˝ J-Box

1G: SINGLE GANG 2G: DUAL GANG