EXHAUST / FRESH AIR HOOD FOR HOMES
Exhaust / fresh air hood for comfort ventilation or kitchen hood extract in homes.
www.swegon.com
Fresh airfl ow @ 20 Pa
Exhaust airfl ow @ 30 Pa
Dimension l/s m3/h l/s m3/h
RHS 125 60 216 75 270
RHS 160 80 288 100 360
RHS 200 135 486 190 684
RHS 250 180 648 220 792
0207-06-2019 Swegon reserves the right to alter speci� cations.
Technical description
Installation instruction
DESIGNRHS is a combined exhaust / fresh air hood for comfort ventilation when two ducts are needed. The bottom part is mounted in the roof slope. Exhaust air / fresh air part is protected under the hood roof and is provided with a small animal protective wire mesh.
MATERIALS AND FINISHABC VHS is manufactured in ABC guaranteed sheet metal with 15 years paint coating warranty to corrosion class C4.Available standard colours are black, brick red and zinc grey. Additional colours are available on request.
PROJECT PLANNINGDesign according to sizing charts
MAINTENANCEEvacuation of aerosols and powder snow or icing can not be ruled out in unfavourable conditions.
OUTLINE DRAWINGINCLUDED PARTS2 pcs. Staps 4.8 x 19 – Top cover2 pcs. Staps 4.8 x 19 – Top lining8 pcs. Staps 4.8 x 19 – Bottom lining1+1 Staps 4.8 x 35 + 4.8 x 19 – storm proof
Top cover
Top lining
Bottom lining
Storm proof pulled down trough bottom lining and attaced to the roof
Tile
Battens
Roof felt
RoofCounterbattens
Bottom liningDim. A (mm) B (mm) C + D ø D
(female)
125 230 ~ 500 Replaces one tile 125
160 230 ~ 500 Replaces one tile 160
200 360 ~ 600 Replaces four tiles 200
250 360 ~ 600 Replaces four tiles 250
0307-06-2019 Swegon reserves the right to alter speci� cations.
Dimensions
1. Mark out where the hood will be placed. A� ected tiles are removed. Make sure that you do not end up above a roof truss, or other inappropriate place. Drill the hole perpendi-cularly to the ceiling. In height, the centre of the hole should be 230 mm from the bottom of the tiles. Sideways, the hole is placed in the middle, measure A to be equal. When moun-ting Ø200 and Ø250 the distance is 400 mm from the bottom of the tiles to the centre of the hole.
2. Make a cut in the roof felt, and insert 20 mm of the bottom lining under the felt. Fasten with the supplied screw. Seal the joints and screws with water resistant sealing compound
3. The above-lying tiles is pushed up against the ridge to facilitate mounting of the top lining. Assemble the top lining at the same angle as the roof. This is done by placing the isolated duct through the bottom lining. Then screw the top lining in the existing battens.
4. Install the top vertical, screw it to the top lining with the supp-lied screws. A� er the assembly the overlying tiles are pushed back to its original position.
Dim. A (mm) B (mm) C + D ø D (female)
125 230 ~ 500 Replaces one tile 125
160 230 ~ 500 Replaces one tile 160
200 360 ~ 600 Replaces four tiles 200
250 360 ~ 600 Replaces four tiles 250
RHS
Diameter of hole=Bottom lining
0407-06-2019 Swegon reserves the right to alter speci� cations.
Ø D
A
B
C
D
MÅTT
Storlek
ABC-VHS
A
mm
B
mmC+D
Ø D
muffmått
125 230 ca 500 Ersätter en betongpanna 125
160 230 ca 500 Ersätter en betongpanna 160
200 360 ca 600 Ersätter fyra betongpannor 200
250 360 ca 600 Ersätter fyra betongpannor 250
DIMENSIONERING
Ljud- och tryckmätningar utförda avSveriges Tekniska Forskningsinstitut.
140
10
15
5
20
2530
40
50607080
30 40 50 60 70 80 140 200 300 400 50090 100
200 250125
120 140 160 180 200 300 400 500 600 700 800 900 1000 1800
160
Tota
l pre
ssur
ePa
Air�ow l/s
Air�ow m³/h
Recommendedworking area
VHS AVLUFT
140
10
15
5
20
2530
40
50607080
30 40 50 60 70 80 140 200 300 400 50090 100
200 250125
120 140 160 180 200 300 400 500 600 700 800 900 1000 1800
160
Tota
l pre
ssur
ePa
Air�ow l/s
Air�ow m³/h
Recommendedworking area
VHS UTELUFT
Angivna data är riktvärden
1800
500
SizingCorrection of sound based
on distance dB(A)
Distance m Correction
5 -22
10 -28
15 -32
20 -34
30 -38
40 -40
50 -42
60 -44
RHS FRESH AIR
RHS EXHAUST AIR
Order key
Exhaust / fresh air hood: RHS aaa -b
Dimension: 125, 160, 200, 250
Colour: B=black, R=brick red, Z=zinc grey
Speci� cation textQMC.2 EXHAUST / FRESH AIR HOOD
Exhaust / Fresh air hood RHS manufactured in ABC guar-anteed sheet metal with 15 years paint coating warranty to corrosion class C4.
THXXSupplier: SwegonType: RHSDimension / colour: XXX-X X pcs.