RHS EXHAUST / FRESH AIR HOOD FOR HOMES Exhaust / fresh air hood for comfort ventilation or kitchen hood extract in homes. www.swegon.com Fresh airflow @ 20 Pa Exhaust airflow @ 30 Pa Dimension l/s m 3 /h l/s m 3 /h RHS 125 60 216 75 270 RHS 160 80 288 100 360 RHS 200 135 486 190 684 RHS 250 180 648 220 792

Transcript of RHS EN 2019 - Swegon · 02 07-06-2019 Swegon reserves the right to alter speci˜ cations. Technical...

Page 1: RHS EN 2019 - Swegon · 02 07-06-2019 Swegon reserves the right to alter speci˜ cations. Technical description Installation instruction DESIGN RHS is a combined exhaust / fresh air

RHSRHS

EXHAUST / FRESH AIR HOOD FOR HOMES

Exhaust / fresh air hood for comfort ventilation or kitchen hood extract in homes.

www.swegon.com

Fresh airfl ow @ 20 Pa

Exhaust airfl ow @ 30 Pa

Dimension l/s m3/h l/s m3/h

RHS 125 60 216 75 270

RHS 160 80 288 100 360

RHS 200 135 486 190 684

RHS 250 180 648 220 792

Page 2: RHS EN 2019 - Swegon · 02 07-06-2019 Swegon reserves the right to alter speci˜ cations. Technical description Installation instruction DESIGN RHS is a combined exhaust / fresh air

0207-06-2019 Swegon reserves the right to alter speci� cations.

Technical description

Installation instruction

DESIGNRHS is a combined exhaust / fresh air hood for comfort ventilation when two ducts are needed. The bottom part is mounted in the roof slope. Exhaust air / fresh air part is protected under the hood roof and is provided with a small animal protective wire mesh.

MATERIALS AND FINISHABC VHS is manufactured in ABC guaranteed sheet metal with 15 years paint coating warranty to corrosion class C4.Available standard colours are black, brick red and zinc grey. Additional colours are available on request.

PROJECT PLANNINGDesign according to sizing charts

MAINTENANCEEvacuation of aerosols and powder snow or icing can not be ruled out in unfavourable conditions.

OUTLINE DRAWINGINCLUDED PARTS2 pcs. Staps 4.8 x 19 – Top cover2 pcs. Staps 4.8 x 19 – Top lining8 pcs. Staps 4.8 x 19 – Bottom lining1+1 Staps 4.8 x 35 + 4.8 x 19 – storm proof

Top cover

Top lining

Bottom lining

Storm proof pulled down trough bottom lining and attaced to the roof

Tile

Battens

Roof felt

RoofCounterbattens

Bottom liningDim. A (mm) B (mm) C + D ø D

(female)

125 230 ~ 500 Replaces one tile 125

160 230 ~ 500 Replaces one tile 160

200 360 ~ 600 Replaces four tiles 200

250 360 ~ 600 Replaces four tiles 250

Page 3: RHS EN 2019 - Swegon · 02 07-06-2019 Swegon reserves the right to alter speci˜ cations. Technical description Installation instruction DESIGN RHS is a combined exhaust / fresh air

0307-06-2019 Swegon reserves the right to alter speci� cations.

Dimensions

1. Mark out where the hood will be placed. A� ected tiles are removed. Make sure that you do not end up above a roof truss, or other inappropriate place. Drill the hole perpendi-cularly to the ceiling. In height, the centre of the hole should be 230 mm from the bottom of the tiles. Sideways, the hole is placed in the middle, measure A to be equal. When moun-ting Ø200 and Ø250 the distance is 400 mm from the bottom of the tiles to the centre of the hole.

2. Make a cut in the roof felt, and insert 20 mm of the bottom lining under the felt. Fasten with the supplied screw. Seal the joints and screws with water resistant sealing compound

3. The above-lying tiles is pushed up against the ridge to facilitate mounting of the top lining. Assemble the top lining at the same angle as the roof. This is done by placing the isolated duct through the bottom lining. Then screw the top lining in the existing battens.

4. Install the top vertical, screw it to the top lining with the supp-lied screws. A� er the assembly the overlying tiles are pushed back to its original position.

Dim. A (mm) B (mm) C + D ø D (female)

125 230 ~ 500 Replaces one tile 125

160 230 ~ 500 Replaces one tile 160

200 360 ~ 600 Replaces four tiles 200

250 360 ~ 600 Replaces four tiles 250

RHS

Diameter of hole=Bottom lining

Page 4: RHS EN 2019 - Swegon · 02 07-06-2019 Swegon reserves the right to alter speci˜ cations. Technical description Installation instruction DESIGN RHS is a combined exhaust / fresh air

0407-06-2019 Swegon reserves the right to alter speci� cations.

Ø D

A

B

C

D

MÅTT

Storlek

ABC-VHS

A

mm

B

mmC+D

Ø D

muffmått

125 230 ca 500 Ersätter en betongpanna 125

160 230 ca 500 Ersätter en betongpanna 160

200 360 ca 600 Ersätter fyra betongpannor 200

250 360 ca 600 Ersätter fyra betongpannor 250

DIMENSIONERING

Ljud- och tryckmätningar utförda avSveriges Tekniska Forskningsinstitut.

140

10

15

5

20

2530

40

50607080

30 40 50 60 70 80 140 200 300 400 50090 100

200 250125

120 140 160 180 200 300 400 500 600 700 800 900 1000 1800

160

Tota

l pre

ssur

ePa

Air�ow l/s

Air�ow m³/h

Recommendedworking area

VHS AVLUFT

140

10

15

5

20

2530

40

50607080

30 40 50 60 70 80 140 200 300 400 50090 100

200 250125

120 140 160 180 200 300 400 500 600 700 800 900 1000 1800

160

Tota

l pre

ssur

ePa

Air�ow l/s

Air�ow m³/h

Recommendedworking area

VHS UTELUFT

Angivna data är riktvärden

1800

500

SizingCorrection of sound based

on distance dB(A)

Distance m Correction

5 -22

10 -28

15 -32

20 -34

30 -38

40 -40

50 -42

60 -44

RHS FRESH AIR

RHS EXHAUST AIR

Order key

Exhaust / fresh air hood: RHS aaa -b

Dimension: 125, 160, 200, 250

Colour: B=black, R=brick red, Z=zinc grey

Speci� cation textQMC.2 EXHAUST / FRESH AIR HOOD

Exhaust / Fresh air hood RHS manufactured in ABC guar-anteed sheet metal with 15 years paint coating warranty to corrosion class C4.

THXXSupplier: SwegonType: RHSDimension / colour: XXX-X X pcs.

PRODUCT