Rev. 07 20-10-14 SWINGER - Downee · Rev. 07 20-10-14 Operatore elettromeccanico per cancelli ad...
Transcript of Rev. 07 20-10-14 SWINGER - Downee · Rev. 07 20-10-14 Operatore elettromeccanico per cancelli ad...
I628
0XX
Re
v. 0
7 2
0-10
-14
Operatore elettromeccanico per cancelli ad anta battente
Istruzioni d’uso ed avvertenze
Electro-mechanical operator for swing gates
Operating instructions and warnings
Opérateur électromécanique pour portails battants
Notice d’emploi et avertissements
Operador electromecánico para puertas con hoja batiente
Instrucciones de uso y advertencias
Operador electromecânico para portões de folha batente
Instruções para utilização e advertências
Siłownik elektromechaniczny do bram skrzydłowych
Instrukcja montażu i użytkowania
Электромеханический привод для распашных ворот
Инструкция по эксплуатации и предупреждения
SWINGER
The Declarat ion of Incorporat ion may be consulted by enter ing
http://www.deasystem.com
DEA SYSTEM S.p.A.Via Della Tecnica, 636013 PIOVENE ROCCHETTE (VI) - ITALY
LIEVORE TIZIANO Amministratore
17
SWINGER Electro-mechanical operator for swing gatesOperating instructions and warnings
Index
1 Warnings Summary 17 8 Messages shown on the Display 262 Product Description 18 9 Start-up 263 Technical data 18 9.1 Installation Test 264 Installation and Assembly 18 9.2 Unlocking and manual operation 265 Electrical Connections 19 10 Maintenance 276 Standard Programming 21 11 Product Disposal 277 Advanced Programming 24
Product ConformityDEA System guarantees the conformity of the product to European Directives 2006/42/CE regarding “machinery safety”, 2004/108/
CE “electromagnetic compatibility” and 2006/95/CE “low voltage electrical equipment”. See Declaration of Incorporation.
1 WARNINGS SUMMARYRead these warnings carefully; failure to respect the following warnings may cause risk situations.
WARNING U S I N G T H I S P R O D U C T U N D E R U N U S U A L C O N D I T I O N S N O T F O R E S E E N B Y T H E M A N U FA C T U R E R C A N C R E A T E S I T U A T I O N S O F D A N -G E R , A N D F O R T H I S R E A S O N A L L T H E C O N D I T I O N S P R E S C R I B E D I N T H E S E I N S T R U C T I O N S M U S T B E R E S P E C T E D .
WARNING DEA S Y S T E M R E M I N D S A L L U S E R S T H A T T H E S E L E C T I O N , P O S I T I O N I N G A N D I N S TA L L A T I O N O F A L L M A -T E R I A L S A N D D E V I C E S W H I C H M A K E U P T H E C O M P L E T E A U T O M A T I O N S Y S T E M , M U S T C O M P LY W I T H T H E E U R O P E A N D I R E C -T I V E S 2006/42/ C E ( M A C H I N E R Y D I R E C T I V E ) , 2004/108/ C E ( E L E C T R O M A G N E T I C C O M P A T I B I L I T Y ) , 2006/95/ C E ( L O W V O L TA G E E L E C T R I C A L E Q U I P M E N T ) . I N O R D E R T O E N S U R E A S U I TA B L E L E V E L O F S A F E T Y , B E S I D E S C O M P LY I N G W I T H L O -C A L R E G U L A T I O N S , I T I S A D V I S A B L E T O C O M P LY A L S O W I T H T H E A B O V E M E N T I O N E D D I R E C T I V E S I N A L L E X T R A E U R O P E A N C O U N T R I E S .
WARNING U N D E R N O C I R C U M S TA N C E S M U S T T H E P R O D U C T B E U S E D I N E X P L O S I V E A T M O S P H E R E S O R S U R R O U N D I N G S T H A T M A Y P R O V E C O R R O S I V E A N D D A M A G E P A R T S O F T H E P R O D U C T .
W A RN I N G T O E N S U R E A N A P P R O P R I A T E L E V E L O F E L E C T R I C A L S A F E T Y A L W A Y S K E E P T H E 230 V P O W E R S U P P LY C A B L E S A P A R T ( M I N I M U M 4 M M I N T H E O P E N O R 1 M M T H R O U G H I N S U L A T I O N ) F R O M L O W V O L TA G E C A B L E S ( M O T O R S P O W E R S U P P LY , C O N T R O L S , E L E C T R I C L O C K S , A E R I A L A N D A U X I L I A R Y C I R C U I T S P O W E R S U P P LY ) , A N D FA S T E N T H E L A T T E R W I T H A P P R O P R I A T E C L A M P S N E A R T H E T E R M I N A L B O A R D S .
WARNING A L L I N S TA L L A T I O N , M A I N T E N A N C E , C L E A N I N G O R R E P A I R O P E R A T I O N S O N A N Y P A R T O F T H E S Y S T E M M U S T B E P E R F O R M E D E X C L U S I V E LY B Y Q U A L I � E D P E R S O N N E L W I T H T H E P O W E R S U P P LY D I S C O N N E C T E D W O R K I N G I N S T R I C T C O M P L I A N C E W I T H T H E E L E C T R I C A L S TA N D A R D S A N D R E G U L A T I O N S I N F O R C E I N T H E N A T I O N O F I N S TA L L A T I O N .
WARNING U S I N G S P A R E P A R T S N O T I N D I C A T E D B Y DEA S Y S T E M A N D / O R I N C O R R E C T R E -A S S E M B LY C A N C R E A T E R I S K T O P E O P L E , A N I -M A L S A N D P R O P E R T Y A N D A L S O D A M A G E T H E P R O D U C T . F O R T H I S R E A S O N , A L W A Y S U S E O N LY T H E P A R T S I N D I C A T E D B Y DEA S Y S T E M A N D S C R U P U L O U S LY F O L L O W A L L A S S E M B LY I N S T R U C T I O N S .
WARNING I N C O R R E C T A S S E S S M E N T O F T H E I M P A C T F O R C E S C A N C A U S E S E R I O U S D A M A G E T O P E O P L E , A N I M A L S O R T H I N G S . DEA S Y S -T E M R E M I N D S T H E I N S TA L L E R M U S T V E R I F Y T H A T T H E I M P A C T F O R C E S , M E A S U R E D A S I N D I C A T E D B Y T H E S TA N D A R D E N 12445, A R E A C T U A L L Y B E L O W T H E L I M I T S S E T B Y T H E S TA N D A R D E N 12453.
WARNING A N Y E X T E R N A L S E C U R I T Y D E V I C E S U S E D F O R C O M P L I A N C E W I T H T H E L I M I T S O F I M P A C T F O R C E S M U S T B E C O N F O R M T O S TA N D -A R D E N 12978 .
WARNING I N C O M P L I A N C E W I T H E U D I R E C T I V E 2002/96/ E C O N W A S T E E L E C T R I C A L A N D E L E C T R O N I C E Q U I P M E N T ( W E E E ) , T H I S E L E C T R I C A L P R O D U C T S H O U L D N O T B E T R E A T E D A S M U N I C I P A L M I X E D W A S T E . P L E A S E D I S P O S E O F T H E P R O D U C T A N D B R I N G I T T O T H E
C O L L E C T I O N F O R A N A P P R O P R I A T E L O C A L M U N I C I P A L R E C Y C L I N G .
Note: Geko is the manufacturer’s name for the Swinger, and may be referenced in this manual.
18
2 PRODUCT DESCRIPTIONModels and contents of the package
GEKO is an operator for the automation of swing gates and doors with door medium and small size. It is essentially made up of:- an operator;- a programmable control panel (adjustable strength, speed, operators stroke, etc..) with built-in 433.92 MHz radio receiver;Inspect the “Contents of the package” (Pic. 1) comparing it with your product, for useful reference during assembly.
TransportGEKO is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.
3 TECHNICAL DATAGEKO
CONTROL BOARD OPERATOR
Power supply (V) 230 V ~ ±10% (50/60 Hz) Motor power supply (V) 24 V
Rated power transformer (VA) 120 VA (230/22V) Capacity (W) 80 W
Fuse F2 (A) (transformer) 2A Max torque (Nm) 180 Nm
Batteries 2x 12V 1,3A Duty cycle (cycles/hour) 20
Fuse F1 (A) (batteries input) 15A Maximum n° of operations in 24 hour 60
24V operators outputs 2x 5A Operating temperature range (°C) -20÷50
Auxiliaries power supply output +24 V max 200mA Opening time 90°(s) 16
“Warning” output +24 V max 15 W Product weight with package (kg) 12 Kg
Electric lock output 24V max 5W or max 1 art. 110 Protection degree IP44
Flashing light output 24 V max 15W
Receiver frequency 433,92 MHz
Transmitters type of coding HCS fix-code - HCS rolling code - Dip-switch
Max remote controllers managed 100
4 INSTALLATION AND ASSEMBLY4.1 For a satisfactory installation of the product is important to:• Verify that the gate complies with the legal requirements and then define the complete project of the installation;• Verify that the gate is well balanced and that it has no points of friction in opening and closing;• Identify an area that allows a smooth and safe manual operation of the operator;• Verify that the operator bulk is compatible with the area chosen for the fitting (Pic. 2);• Ensure that the space for the rotation of the arm is sufficient (Pic. 3).• Use the length/weight graphic and the provided installations dimensions (Pic. 4) evaluating whether you prefer a 90° or a 120°
opening.
4.2 Once you have defined and satisfied these requirements, proceed with the assembly:• fix the operator fixing plate to the pillar by using screws and plugs suitable to the type of surface and material (Pic. 5);• mount the straight arm by using the supplied screw and washer (Pic. 6);• insert the operator inside the wall connection plate and fix it with the provided screws and nuts (Pic. 7);• Mount the swing fixing hinge and the curved arm to the straight arm by using the provided pins and seeger rings (Pic. 8);• weld the hinge to the gate or fix it with screws suitable to the type of material;
4.3 How to unlock the operatorWARNING Disconnect the power supply from the control panel before releasing the operator. In case you cannot turn the power off, you will necessarily have to re-lock the motor in the position in which it was unlocked.
Lift the cover window (Pic. 9a) and, after having inserted the unlocking key, rotate clockwise until it stops (Fig. 9b).
19
4.4 How to fix and adjust the mechanical limit switches• Unlock the operator;• Rotate the wing to the position of complete opening, position the mechanical limit switch on the stop with the straight arm and fasten it
with the provided screws (Pic. 10). If necessary, you can mount a second mechanical limit switch for the closing stop. In this case follow the above directions by moving the door in the desired closed position and fix it with the screws provided in detention;
• Repeat the previous step for a possible second door;• Secure the protective cover on the straight arm with the screws provided (Pic. 10).
5 ELECTRICAL CONNECTIONSExecute the wiring following the directions of table 1 and diagrams on page 20.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole disconnection from the power supply, with a contact opening of 3 mm.WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm2.
Table 1 “terminal board connections”
1-2 +24 V power supply output for auxiliary devices 200mA
3-4 22 V ~ transformer power supply input5-6 24 V battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity indications).
7-8 Operator 1 output
9 Connection of motors metallic parts
10-11 Operator 2 output (if present)
12-13 24 V max 15 W output for open gate fix warning light (if P052=0), flashing (if P052=1) or courtesy light (if P052>1)
14-1514 (-) “Boost” output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (if P062=5) or temporized output (if P062>5).15 (+)
16-17 24 V Flashing light output max 15W art. Lumy/24A/S
18-1918 - N.C. Input 6 STOP. In case of intervention, it stops the movement of both motors during any
operation. If unused, short circuit.If
the
inst
alla
tion
requ
ires
diffe
rent
com
man
ds
and
/ or
add
ition
al t
o th
e st
anda
rd,
you
can
confi
gure
eac
h in
put t
o th
e re
quire
d ra
te.
Ref
er to
Cha
pter
“Ad
vanc
ed P
rogr
amm
ing”
.
19 - Com
20-2120 - N.C. Input 5 PHOTO 2. When enabled (see parameter P051 in the table), activation of PHOTO
2 provokes: an inversion of direction (during closing), the arrest of the movement (during opening), prevent the start (gate closed). If unused, short circuit.21 - Com
22-2322 - N.C. Input 4 PHOTO 1. When enabled (see parameter P050 in the table), activation of PHOTO
1 provokes: an inversion of direction (during closing), the arrest of the movement (during opening), prevent the start (gate closed). If unused, short circuit.23 - Com
24-2524 - N.C. Input 3 SAFETY. If activated, it causes the inversion. See P055 and P056 on the parame-
ters table. If unused, short circuit.25 - Com
26-2726 - N.O.
Input 2 PED. If activated, it opens motor nr. 1 only.27 - Com
28-2928 - N.O. Input 1 START. In case of intervention it provokes: the operator opening or closing. It may
operate as “inversion” mode (P049=0) or “step by step” mode (P049=1).29 - Com
30 Aerial signal input
31 Ground aerial input
32-3332 (+)
DE@NET mains input (unused at the moment)33 (-)
CON 1 230 V ~ ±10% (50/60 Hz) power supply inputCON 2 Connection of encoder to operator 2 (1-2-3)CON 3 Connection of power supply to operator 2 + ground (4-5-6)
J5 J9 Encoder selection Jumper:•A position = operators with encoder (remind to set P029=0)•B position = operators without encoder (remind to set P029=1)AB AB
20
79
810
1112
1314
1516
17
181920212223242526272829
3130
3332
21 43 65
AB
AB
FLA
SHW
ARN
ING
J5J9
LOCK
ELECTRIC LOCK art.110
2 x
1 m
m2
2 x
0,5
mm
2
2 x
1 m
m2
3 x
0,22
mm
2
2 x
1,5
mm
2
RG58
OPEN GATE WARNING LIGHT 24V 15w
INTE
RNA
L W
IRIN
G S
ETBY
TH
E FA
CTO
RY
EXTE
RNA
L W
IRIN
G S
ETBY
TH
E IN
STA
LLER
POW
ER S
UPPL
Y23
0V~
50Hz
±10
%
CON
1
CON2
CON3
CON
2
CON
3
* W
ARNI
NG:
If th
e in
stalla
tion
requ
ires d
i�er
ent c
omm
ands
and
/ o
r add
ition
al to
the s
tand
ard,
you
can
con
gure
eac
h in
put
to t
he
requ
ired
rate
. Re
fer
to C
hapt
er
“Adv
ance
d Pr
ogra
mm
ing”.
ENC
M1
ENC
M2
FN
1 x
1,5
mm
2
12
34
56
123456
FLA
SH
LUM
Y/24
A/S
max
15W
N.O
.
N.O
.
N.C
.
SAFE
TY (O
nly if
need
ed)
STA
RT
PED
TXRX
TXRX COM
N.C.
N.O.
PHO
TO 2
PHO
TO 1
COM
N.O
.
COM
N.O
.
COM
N.C
.
COM
N.C
.
COM
N.C
.
2 x
0,5
mm
2
2 x
0,5
mm
2
2 x
0,5
mm
2
2 x
0,5
mm
2
2 x
0,5
mm
2
2 x
0,5
mm
2
N.C
.
STO
P (O
nly if
need
ed)
COM
N.C
.
2 x
0,5
mm
2
BLUE
RED
BROWN
WHITE
GREEN
2 x
0,5
mm
2
F2
Mot
2 (O
nly if
pres
ent)
COM
N.C.
N.O.
F1
BLU
E
RED
BRO
WN
WH
ITE
GRE
EN
21
6 STANDARD PROGRAMMING
1 Power SupplyGive power supply, the display shows the following symbols “ ”, “ ”, “ ” and then “- - - -”.
* If the control panel has already been programmed and the power fails or is switched off - once power is returned and a START command is given, the position reset procedure is performed (see “rESP” in the table “WORKING STATUS MESSAGES” on page 26.
2 Visualisation of inputs and operations-counter status1. Press the key for 15 seconds;
2. The display will show respectively:Inputs status (check it’s correct);
Total operations counter (* see P064):i.g.: = 3x1000* = 3000 operations performed
Maintenance operations-counter (* see P065):i.g.: = 5*x500 = 2500 operations remaining be-fore the maintenance intervention request ( = ma-noeuvres-counter disabled)
3. Hold down the key to display a cyclic 3 options, or rele-ase the button to exit the parameter.
3 Selection type of operators ! IMPORTANT !1. Scroll down the parameters with and keys until you visua-
lise P028;2. Access the parameter by pressing the key;3. Verify that the value corresponds to d000 (GEKO), otherwise, you
must select it by pressing and keys;4. Confirm your choice by pressing the key (display returns again
to P028).
4 Selection operating with or without encoder ! IMPORTANT !Warning: Remember to correctly set the jumpers J5 and J9.
1. Scroll down the parameters with and keys until you visua-lise P029;
2. Access the parameter by pressing the key;3. Acting on and keys, set: - d000=for operators with encoder; - d001=for operators without encoder;4. Confirm your choice by pressing the key (display returns again
to P029).
22
5 Selection 1 or 2 operators functioning1. Scroll down the parameters with and keys until you visua-
lise P030;2. Access the parameter by pressing the key;3. Acting on and keys, set: - d001=for a single motor operating; - d002=for 2 motors operating;4. Confirm your choice by pressing the key (display returns again
to P030).
6 Motor stroke learning
1. Scroll down the parameters with and keys until you visualise P003;2. Access the parameter by pressing the key;3. When “ ” flashes, continue pressing the key;4. Release the key when “ ” stops flashing; the learning procedure starts;5. Wait for the door (or doors in case of using 2 motors) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to “Start” button (or pressing the “OK” on the control panel) simulating the stroke.
6. Once the procedure is ended, the display will show “- - - -“.
WARNING Once you have executed the learning stroke, operate a complete cycle (opening/closing) and then check the manual release to make sure it is working properly. If it’s to “hard” increase the value of P057 of 1 or more.
7 Transmitters learning7.1 Transmitters coding selection
1. Scroll down the parameters with and keys until you visualise P027;
2. Access the parameter by pressing the key;3. Select the type of transmitter by scrolling and keys: - d000=fix rolling-code (suggested); - d001=complete rolling-code; - d002=dip-switch;4. Confirm by pressing on the key (display shows again P027).
Warning: If you need to vary the type of encoding, and only if other remo-tes with different encoding are memorized, you need to erase memory (P004) AFTER you have set the new encoding.
23
7.2 Learning
1. Scroll down the parameters with and keys until you visualise P005;
2. Confirm by pressing on the key;3. When the symbol “ ” appears, press on
any key of the transmitter you want to memo-rize;
4. The display visualizes the number of the trans-mitter just memorized and then “ ”;
5. Memorize all necessary transmitters repeat-ing this procedure from step 3;
6. Wait 10 seconds before quitting the memori-zation mode, display shows now “- - - -“.
Warning: In the case of rolling code remotes, the receiver can be put into learning mode by pressing the hidden button on a remote control previously learned.Warning: When using personalized transmitters, after entering P005 the learning of the first personalized transmitter is possible only by pressing its hidden button. Afterwards, only transmitters personalized with the same encryption key can be memorized (through the usual procedure), unless a memory reset is carried out (P004).
8 Adjustment of operating parametersIf you need to modify the operating parameters (force, speedness
etc..):
1. Scroll down the parameters until you visualize the desire para-meter (i.g. P032);
2. Access the parameter by pressing the key;3. By pressing on and keys, set up the desired value;4. Confirm by pressing on the key (display shows the parameters
previously selected).
For the complete list of the “Operating Parameters” See the table on page. 29.
9 Programming completeWARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - -”, the operator is now ready again for new manoeuvres.
To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see on page 24.
24
7 ADVANCED PROGRAMMINGHere are some added programming procedures relating to remotes memory management and advanced configuration of the control
inputs.
1 Deletion of memorized transmitters1.1 Deletion of all transmitters
1. Scroll down the parameters until you visualize P004;2. Confirm by pressing on the key;3. When “ ” is flashing, press the key for a few sec-
onds;4. Release the key as soon as “ ” stops flashing;5. All memorized transmitters have been deleted (display
shows again P004).
1.2 How to search and delete a transmitter
1. Scroll down the parameters until you visualize P006;2. Confirm by pressing on the key;3. By pressing on and , keys, select the transmitter you
want to delete (eg. );4. When “ ” flashes, confirm the deletion by pressing
the key for a few seconds;5. Release the key when appears “ ”;6. The selected transmitter is deleted (display shows again
P006).
2 Resetting of default parameters1. Scroll down the parameters until you visualize P007;2. Confirm by pressing on the key;3. When “ ” flashes, press the key;4. Release the key as soon as “ ” stops flashing;
Default parameters for the configuration currently in use are restored;
5. At the end of the operation display returns to P007.
Warning: After you restore the default parameters, you must program the control panel again and adjust all ope-rating parameters, in particular, remember to properly set the configuration of parameters (P028 - P029 - P030 – operator configuration).
3 Locking-Unlocking access to programmingBy using a “dip-switch” remote (regardless of the type of remotes already memorized) it’s possible to lock-unlock access to the program-ming of the control panel to avoid tampering. The remote setting is the locking-unlocking code verified by the control board.
3.1 Locking access to programming
1. Scroll through the parameters with the buttons and until the display shows P008;
2. Access the parameter by pressing the button ;3. The display shows alternately the writing
to indicate that the control board is waiting for the transmission of the block code;
4. Within 10 seconds press CH1 on the “TX Master”, the display shows before returning to the list of parameters;
5. Access to programming is locked.
25
3.2 Unlocking access to programming
1. Scroll through the parameters with the buttons and until the display shows P008;
2. Access the parameter by pressing the button ;3. The display shows alternately the writing
to indicate that the control board is waiting for the transmission of the unlocking code;
4. Within 10 sec. press the CH1 of the “TX Master”, the display shows before returning to the list of parameters;
5. Access to programming is unlocked.
3.3 Unlocking access to programming and global reset
WARNING! This procedure involves the loss of all stored set-tings.
The procedure allows the unlocking of the control panel without having to know its unlocking code.Following this release, in particular, remember to properly set the configuration of parameters (P028 - P029 - P030 – operator configuration). You will also need to repeat the measurement of impact forces to ensure the installation compliance to standards.
1. Scroll through the parameters with the buttons and until the display shows P008;
2. Access the parameter by pressing the button ;3. The display shows alternately the writing ;4. Press the button , the display shows the flashing writing
;5. Press the button again and hold for 5 seconds (releasing it be-
fore, the procedure is terminated): The display shows the fixed writing followed by , before returning to the list of parameters;
6. Access to programming is unlocked.
4 Inputs configurationWhere the installation requires different commands and / or additional to the standard ones described by plan, you can configure each input for the operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the and to see that corresponding to the desired one:
● P017=for INPUT 1; ● P018=for INPUT 2; ● P019=for INPUT 3; ● P020=for INPUT 4; ● P021=for INPUT 5; ● P022=for INPUT 6;2. Confirm by pressing on the key to get access to the parameter (eg.
P018);3. Scroll down with the and , keys to set the value corresponding to
the desired operation (refer to table “Input Configuration parameters” on page 28);
4. Confirm by pressing on the key (display shows again P018).5. Execute the new connection to the input just reconfigured.
5 Programming completeWARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - -”, the operator is now ready again for new manoeuvres.
26
8 MESSAGES SHOWN ON THE DISPLAYWORKING STATUS MESSAGES
Mess. DescriptionGate is closedGate is openedOpening under wayClosing under wayWhile in step-by-step mode, the control board awaits further instructions after a start commandStop command receivedReset current position: The control unit has just been turned on after a power failure, or the gate has exceeded the maximum number (80) of inversions allowed without ever getting to the closing stroke, or the maximum number (3 ) of consecutive operations allowed of the anti- cru-shing device.Once the control unit has been reset and open command given the gate will start moving at slow speed, until it reaches end of travel.
ERROR MESSAGES
Mess. Description Possible solutions
Error position: The reset position procedure is not suc-cessful. The control panel is awaiting commands.
- Make sure there are no specific frictions and / or obstacles during the run;- Give a start pulse to initiate a position reset procedure;- Verify that the operation is completed successfully, manually helping the run, if ne-cessary;- Adjust power and speed settings if necessary.
External photocells and/or safety devices are activated or out of order. - Make sure that all safety devices and/or photocells installed are working properly.
Possible failure to the control board power circuit. - Disconnect and connect power supply. Give a start impulse, if this error appears again, replace the control board.
Time-out operators run: The engine/s exceeded the maximum operating time (4min) without ever stopping.
- Give a start pulse to start the position reset procedure;- Ensure that this operation is successful.
Time-out obstacle detection: With anti-crushing sensor disabled, was still detected the presence of an obsta-cle that prevents movement of the leaf for a period of 10 seconds more.
- Make sure there are no specific frictions and / or obstacles during the run;- Give a start pulse to initiate a position reset procedure;- Verify that the operation is completed successfully.
Operators mouvement not detected.- Make sure that operators and encoders connections are well done.- Check that jumpers J5 and J9 are well positioned as shown on the electric wiring.- If this error appears again, replace the control panel.
9 START-UPThe start-up phase is very important to ensure maximum security and compliance to regulations, including all the requirements of EN
12445 standard which establishes the test methods for testing the automation for gates.DEA System reminds that all installation, maintenance, cleaning or repair operations on any part of the system must be performed
exclusively by qualified personnel who must be responsible of all texts requie by the eventual risk;
9.1 Installation test
The testing operation is essential in order to verify the correct installation of the system. DEA System wants to summarize the proper testing of all the automation in 4 easy steps:
• Make sure that you comply strictly as described in paragraph 2 “WARNINGS SUMMARY”;• Test the opening and closing making sure that the movement of the leaf match as expected. We suggest in this regard to perform various tests to assess the smoothness of the gate and defects in assembly or adjustment;• Ensure that all safety devices connected work properly;• Perform the measurement of impact forces in accordance with the standard 12445 to find the setting that ensures compliance with
the limits set by the standard EN12453.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assembly can create a risk to people, animals and property and also damage the product. For this reason, always use only the parts indicated by DEA System and scrupulously follow all assembly instructions.
9.2 Unlocking and Manual operation
In the event of malfunctions or simple power failure, release the motor (Pic. 9) and perform the operation manually.The knowledge of the unlocking device is very important because, in times of emergency, lack of speed in operating this device can
cause danger.
WARNING The efficancy and safety of manual operation of the automation is guaranteed by DEA System only if the installation has been installed correctly and with original accessories.
27
10 MAINTENANCEGood preventive maintenance and regular inspection ensure
long working life. In the table below you will find a listo f inspections/maintenance operations to be programmed and executed periodi-cally.
Consult the TROUBLE-SHOOTING” table whenever anomalies are observed in order to find the solution to the problem and contact DEA System directly whenever the solution required is not provided.
INTERVENTION TYPE PERIODICITYcleaning of external surfaces 6 months
checking of screw tightening 6 months
checking of release mechanism operation 6 months
greasing of articulated joint 1 year
TROUBLE-SHOOTING
Description Possible solutions
When the opening command is given, the gate wing fails to move and the operator’s electric motor fails to start.
The operator is not receiving correct power supply. Check all connections, fuses, and the power supply cable conditions and replace or repair it if necessary. If the gate does not close check if the photocells work properly.
When the opening command is given, the motor starts but the gate leaf fails to move.
Make sure the unlocking system is closed.Make sure that the electronic device for power adjustment is in good condition.
The operator jerks or is noisy during movement, it stops mi-dway or else it does not start.
If the leaf of the gate does not move freely, release the operator and readjust the rotation points.The power of the gearmotor may be insufficient for the characteristics of the gate’s leaf; check the choice of model whenever required.If the plate fastening the operator to the gate bends or is inappropriately fastened, repair it or reinforce it.
11 PRODUCT DISPOSALGEKO consists of materials of various types, some of which can be recycled (electrical cables, plastic, aluminum, etc. ..) while others
must be disposed of (electronic boards and components).Proceed as follows:
1. Disconnect the power supply;2. Disconnect and disassemble all the accessories connected. Follow the instructions in reverse to that described in the section “Installa-
tion”;3. Remove the electronic components;4. Sorting and disposing of the materials exactly as per the regulations in the country of sale.
WARNING In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to your local municipal collection point for recycling.
28
PAR
.PR
OCE
DU
RE
SETT
ABLE
VAL
UES
PROGRAMMING PROCEDURES
Posi
tioni
ng o
f ope
rato
r 1
Posi
tioni
ng o
f ope
rato
r 2
Mem
oriz
atio
n of
the
mot
ors’
stro
ke
Del
etio
n of
tran
smitt
ers
Tran
smitt
ers
mem
oriz
ing
Sear
ch a
nd d
elet
ion
of a
tran
smitt
er
Load
ing
of s
tand
ard
para
met
ers:
the
list i
s up
dat
ed w
ith fa
ctor
y se
tting
s
Lock
acc
ess
to p
rogr
amm
ing
How
to le
arn
conn
ecte
d D
E@N
ET d
evic
es (u
nuse
d at
the
mom
ent)
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
PAR
.SE
TTAB
LE V
ALU
ESSE
TTAB
LE V
ALU
ES
DEF
AULT
VAL
UES
(for d
iffer
ent s
tand
ards
of
inst
alla
tion)
TYPE 01
INPUTS CONFIGURATION PARAMETERS
INPU
T_3
sele
ctio
ning
inpu
t typ
e•
000
: IN
3 ty
pe=f
ree
cont
act
• 0
01: I
N3
type
=con
stan
t res
ista
nce
8K2
INPU
T_1
oper
atin
g se
lect
ion
• 0
00: N
ONE
(unu
sed
para
met
er)
• 0
01: S
TART
(sta
rt)
• 0
02: P
ED. (
pede
stria
n)•
003
: OPE
N (s
epar
ated
ope
n)•
004
: CLO
SE (s
epar
ated
clo
se)
• 0
05: O
PEN
_PM
(man
pre
sent
ope
n)•
006
: CLO
SE_P
M (m
an p
rese
nt c
lose
)•
007
: ELO
CK-IN
(ele
ctric
-lock
act
ivat
ion.
See
P06
2)•
008
: PH
OTO
1 (p
hoto
cell
1)•
009
: PH
OTO
2 (p
hoto
cell
2)•
010
: SAF
ETY
1 (s
afet
y rib
1)
• 0
11: S
TOP
(lock
)•
012
: FCA
1 (o
peni
ng li
mit
switc
hes
Mot
1)•
013
: FCA
2 (o
peni
ng li
mit
switc
htes
Mot
2)•
014
: FCC
1 (c
losi
ng li
mit
switc
hes
Mot
1)•
015
: FCC
2 (c
losi
ng li
mit
switc
hes
Mot
2)•
016
: SAF
ETY
2 (s
afet
y rib
2)
IN1
INPU
T_2
oper
atin
g se
lect
ion
IN2
INPU
T_3
oper
atin
g se
lect
ion
IN3
INPU
T_4
oper
atin
g se
lect
ion
IN4
INPU
T_5
oper
atin
g se
lect
ion
IN5
INPU
T_6
oper
atin
g se
lect
ion
IN6
29
TYPE 01
INPUTS CONFIGURATION PARAMETERS
Allo
catio
n of
CH
ANN
EL 1
of r
emot
es•
000
: NON
E (u
nuse
d pa
ram
eter
)•
001
: STA
RT (s
tart
)•
002
: PED
ESTR
IAN
(ped
estri
an)
• 0
03: O
PEN
(sep
arat
ed o
pen)
• 0
04: C
LOSE
D (s
epar
ated
clo
se)
• 0
05: O
PEN
_PM
(man
pre
sent
ope
n)•
006
: CLO
SED
_PM
(man
pre
sent
clo
se)
• 0
07: E
LOCK
-IN (e
lect
ric-lo
ck a
ctiv
atio
n. S
ee P
062)
CH1
Allo
catio
n of
CH
ANN
EL 2
of r
emot
esCH
2
Allo
catio
n of
CH
ANN
EL 3
of r
emot
esCH
3
Allo
catio
n of
CH
ANN
EL 4
of r
emot
esCH
4
Sele
ctio
n of
type
of r
emot
es•
000
: HCS
fix-
code
• 0
01: H
CS ro
lling
-cod
e•
002
: Dip
-sw
itch
OPERATORSCONFIGURATION PARAMETERS
Sele
ctio
n ty
pe o
f ope
rato
rs•
000
: GEK
O•
001
: LOO
K - M
AC (U
nuse
d)•
002
: GH
OST
100/
200
(Unu
sed)
• 0
03: 5
00 -
502
(Unu
sed)
Sele
cted
wor
k w
ith o
r with
out e
ncod
ers.
CA
UTIO
N: R
emem
ber t
o co
rrec
tly s
et th
e ju
mpe
rs J5
and
J9 (s
ee ta
ble
1)W
ARN
ING
: J5,
J9 a
nd P
029
mus
t be
set c
orre
ctly
bef
ore
perfo
rmin
g th
e pr
oced
ure
for p
rogr
amm
ing
• 0
00: m
otor
s w
ith e
ncod
er•
001
: eng
ines
with
out e
ncod
er
Sele
ctio
ning
ope
rato
rs n
umbe
r•
001
: one
ope
rato
r•
002
: tw
o op
erat
ors
OPERATING PARAMETERS
Oper
ator
s sp
eed
adju
stm
ent d
urin
g sl
ow-d
own
whi
le o
peni
ng15
%to
t.....
......
......
......
.100
%to
t
Oper
ator
s sp
eed
adju
stm
ent d
urin
g th
e st
roke
whi
le o
peni
ng15
%to
t.....
......
......
......
.100
%to
t
Oper
ator
s sp
eed
adju
stm
ent d
urin
g th
e st
roke
whi
le c
losi
ng15
%to
t.....
......
......
......
.100
%to
t
Oper
ator
s sp
eed
adju
stm
ent d
urin
g sl
ow-d
own
whi
le c
losi
ng15
%to
t.....
......
......
......
.100
%to
t
Slow
dow
n du
ratio
n ad
just
men
t whi
le o
peni
ng0%
tot..
......
......
......
......
..80%
to
Slow
dow
n du
ratio
n ad
just
men
t whi
le c
losi
ng0%
tot..
......
......
......
......
..80%
to
Oper
ator
1 fo
rce
adju
stm
ent w
hile
ope
ning
(if =
100
% o
bsta
cle
dete
ctio
n de
activ
ated
)15
%to
t…...
......
......
......
......
100%
tot
Oper
ator
n.1
forc
e ad
just
men
t whi
le c
losi
ng (i
f = 1
00%
obs
tacl
e de
tect
ion
deac
tivat
ed)
15%
tot…
......
......
......
......
...10
0%to
t
Oper
ator
n.2
forc
e ad
just
men
t whi
le o
peni
ng (i
f = 1
00%
obs
tacl
e de
tect
ion
deac
tivat
ed)
15%
tot…
......
......
......
......
...10
0%to
t
Oper
ator
n.2
forc
e ad
just
men
t whi
le c
losi
ng (i
f = 1
00%
obs
tacl
e de
tect
ion
deac
tivat
ed)
15%
tot…
......
......
......
......
...10
0%to
t
Auto
mat
ic c
losi
ng ti
mes
adj
ustm
ent (
if =
0 au
tom
atic
clo
sing
dea
ctiv
ated
)0s
ec...
......
......
......
......
......
..255
sec
Pede
stria
n au
tom
atic
clo
sing
tim
e ad
just
men
t (se
= 0
ped
estri
an a
utom
atic
clo
sing
dea
ctiv
ated
)0s
ec...
......
......
......
......
......
..255
sec
Pede
stria
n st
roke
dur
atio
n ad
just
men
t5%
tot…
......
......
......
......
...10
0%to
t
Pre-
flash
ing
time
adju
stm
ent
0sec
……
.10s
ec
Adju
stm
ent o
f pha
se d
ispl
acem
ent t
ime
whi
le o
peni
ng0s
ec…
……
……
30se
c
Adju
stm
ent o
f pha
se d
ispl
acem
ent t
ime
whi
le c
losi
ng0s
ec…
……
……
30se
c
Colle
ctiv
ity fu
nctio
n: if
it is
act
ivat
ed it
dea
ctiv
ates
bot
h op
enin
g a
nd c
losi
ng in
puts
for t
he w
hole
dur
atio
n of
aut
omat
ic o
peni
ng
and
clos
ing
• 0
00: “
colle
ctiv
ity fu
nctio
n” d
eact
ivat
ed•
001
: “co
llect
ivity
func
tion”
act
ivat
ed
Ram
blo
w fu
nctio
n: it
pus
hes
the
mot
ors
clos
ed fo
r one
sec
ond
befo
re e
ach
open
ing
mov
emen
t, so
as
to e
ase
the
elec
tric-
lock
re
leas
e•
000
: “ra
m b
low
” de
activ
ated
• 0
01: “
ram
blo
w fu
nctio
n” a
ctiv
ated
30
TYPE 01
OPERATING PARAMETERS
“Rev
ersa
l” m
ode
sele
ctio
n (d
urin
g th
e m
anoe
uvre
a c
omm
and
impu
lse
reve
rse
the
mou
vem
ent)
or “
step
by
step
” (d
urin
g th
e m
anoe
uvre
a c
omm
and
impu
lse
stop
s th
e m
ouve
men
t). A
nex
t im
puls
e re
star
t the
ope
rato
r to
the
oppo
site
dire
ctio
n.•
000
: “re
vers
al fu
nctio
n”•
001
: “st
ep b
y st
ep fu
nctio
n”
PHOT
O 1
PHOT
O in
put f
unct
ioni
ng: I
f=0:
pho
toce
ll en
able
d w
hile
clo
sing
and
sta
rtin
g w
hen
the
gate
is s
topp
ed; i
f=1
phot
ocel
ls
are
alw
ays
enab
led;
if=2
pho
toce
lls a
re e
nabl
ed w
hile
cl
osin
g on
ly. W
hen
enab
led,
its
activ
atio
n pr
ovok
es: t
he
inve
rsio
n (w
hile
clo
sing
), th
e st
op (w
hile
ope
ning
) and
pre
vent
the
star
ting
(whe
n ga
te is
clo
sed)
.If=
3-4-
5, th
e op
erat
ion
is th
e sa
me
as th
e va
lues
0-1
-2 b
ut w
ith “
clos
e im
med
iate
ly”
enab
led:
in a
ny c
ase,
dur
ing
the
open
ing
and/
or t
he p
ause
tim
e, r
emov
al o
f a p
ossi
ble
obst
acle
cau
ses
the
gate
aut
omat
ical
ly c
lose
s af
ter
a fix
ed d
elay
of 5
sec
.
• 0
00: p
hoto
cell
enab
led
whi
le c
losi
ng a
nd w
hen
gate
is s
topp
ed•
001
: pho
toce
lls a
lway
s en
able
d•
002
: pho
toce
lls e
nabl
ed o
nly
whi
le c
losi
ng•
003
: as
000
but w
ith “
clos
e im
med
iate
ly”
enab
led
• 0
04: a
s 00
1 bu
t with
“cl
ose
imm
edia
tely
” en
able
d•
005
: As
002
but w
ith “
clos
e im
med
iate
ly”
enab
led
PHOT
O 2
Oper
atio
n m
ode
sele
ctio
n of
the
war
ning
ligh
t out
put:
If =
0 “w
arni
ng li
ght”
(out
put a
lway
s ON
whe
n th
e ga
te is
ope
n, O
FF a
fter a
clo
sing
ope
ratio
n),
If =
1 “fl
ashi
ng w
arni
ng li
ght”
(slo
w in
term
itten
t out
put d
urin
g op
enin
g an
d fa
st w
hile
clo
sing
, alw
ays
ON a
t gat
e op
ened
, alw
ays
OFF
at th
e en
d of
a c
losi
ng o
pera
tion
only
),If>
1 “
cour
tesy
ligh
t” (o
utpu
t ON
dur
ing
each
mov
emen
t, OF
F w
hen
the
mot
or s
tops
, afte
r the
set
ting
dela
y)
• 0
00:
“fix
war
ning
ligh
t”•
001
: “fl
ashi
ng w
arni
ng li
ght”
• >
001
: “co
urte
sy li
ght”
off
dela
y(2
sec…
……
……
…25
5sec
)
Sear
ches
for e
nd o
f stro
ke w
hile
ope
ning
too:
whe
n ac
tivat
ed,
oper
ator
s st
op o
nly
at th
eir a
rriv
al e
t the
end
of s
troke
, als
o w
hile
op
enin
g.W
arni
ng: D
urin
g th
e em
erge
ncy
oper
atio
n (rE
SP),
the
mot
or e
xecu
tes
the
first
man
euve
r whi
le o
peni
ng. I
n ad
ditio
n, if
any
lim
it sw
itche
s, th
e pa
ram
eter
is fo
rced
to 1
.
• 0
00: S
top
whe
n op
enin
g o
n a
mem
oriz
ed p
oint
• 0
01: S
top
whe
n op
enin
g on
the
end
of s
troke
“sof
t sta
rt”
func
tion:
mot
ors
acce
lera
te g
radu
ally
unt
il th
ey re
ach
the
set s
peed
, avo
idin
g su
dden
dep
artu
res
• 0
00: “
soft
star
t” d
eact
ivat
ed•
001
: “so
ft st
art”
act
ivat
ed•
002
: “lo
ng s
oft s
tart
” ac
tivat
ed
Adju
st th
e in
vers
ion
on o
bsta
cle
perio
d (d
etec
ted
by in
tern
al a
nti-c
rush
ing
sens
or o
r by
the
safe
ty in
put w
hen
activ
ated
): If
= 0
it m
akes
a c
ompl
ete
inve
rsio
n, if
> 0
indi
cate
s th
e du
ratio
n (in
sec
onds
) of t
he ru
n, a
fter i
nver
sion
resu
lting
from
det
ectio
n of
an
obst
acle
dur
ing
the
open
ing.
• 0
00: c
ompl
ete
reve
rsal
on
obst
acle
• >
000:
dur
atio
n of
reve
rsal
on
obst
acle
(1
sec…
……
……
..10s
ec)
Adju
st th
e in
vers
ion
on o
bsta
cle
perio
d (d
etec
ted
by in
tern
al a
nti-c
rush
ing
sens
or o
r by
the
safe
ty in
put w
hen
activ
ated
): If
= 0
it m
akes
a c
ompl
ete
inve
rsio
n, if
> 0
indi
cate
s th
e du
ratio
n (in
sec
onds
) of t
he ru
n, a
fter i
nver
sion
resu
lting
from
det
ectio
n of
an
obst
acle
dur
ing
the
clos
ing.
• 0
00: c
ompl
ete
reve
rsal
on
obst
acle
• >
000:
dur
atio
n of
reve
rsal
on
obst
acle
(1
sec…
……
……
..10s
ec)
Faci
litat
ion
man
ual r
elea
se: I
f≠0,
afte
r det
ectin
g th
e lo
ckin
g st
op, t
he e
ngin
e re
vers
es fo
r a b
rief t
ime
to re
leas
e th
e pr
essu
re o
n it,
and
thus
faci
litat
e th
e m
anua
l rel
ease
. The
set
val
ue s
how
s th
e le
ngth
of t
he in
vers
ion.
If=0
func
tion
disa
bled
• 0
00: f
acili
tatin
g re
leas
e di
sabl
ed•
>00
0: fa
cilit
atio
n ac
tivat
ed w
ith re
leas
e tim
e eq
ual t
o:(1
x25m
s……
20x2
5ms)
Adju
stm
ent
of t
he o
peni
ng s
troke
mar
gin:
it a
djus
ts t
he d
urat
ion
of t
he la
st p
art
of t
he s
troke
dur
ing
whi
ch a
n ob
stac
le is
in
terp
rete
d as
a s
troke
, blo
ckin
g th
e m
otor
with
out p
erfo
rmin
g th
e in
vers
ion.
Fo
r mot
ors
with
enc
oder
s, th
e se
t val
ue in
dica
tes
the
num
ber o
f rev
olut
ions
of t
he ro
tor;
whi
le fo
r mot
ors
with
out e
ncod
er, t
he
valu
e is
exp
ress
ed in
% o
f the
max
imum
stro
ke.
War
ning
: for
mot
ors
with
out e
ncod
er, i
f P03
5 (d
urat
ion
slow
-dow
n w
hile
ope
ning
) is
>10%
, it f
orce
s th
e st
roke
det
ectio
n m
argi
n so
that
it’s
the
sam
e th
an th
e sl
ow-d
own.
1....
......
......
..255
(m
otor
s w
ith e
ncod
er)
0%…
......
......
100%
(m
otor
s w
ithou
t enc
oder
)
Adju
stm
ent o
f the
clo
sing
stro
ke m
argi
n: it
adj
usts
the
dura
tion
of th
e la
st p
art o
f the
stro
ke d
urin
g w
hich
an
obst
acle
is in
terp
rete
d as
a s
troke
, blo
ckin
g th
e m
otor
with
out p
erfo
rmin
g th
e in
vers
ion.
Fo
r mot
ors
with
enc
oder
s, th
e se
t val
ue in
dica
tes
the
num
ber o
f rev
olut
ions
of t
he ro
tor;
whi
le fo
r mot
ors
with
out e
ncod
er, t
he
valu
e is
exp
ress
ed in
% o
f the
max
imum
stro
ke.
War
ning
: for
mot
ors
with
out e
ncod
er, i
f P03
6 (d
urat
ion
slow
-dow
n w
hile
clo
sing
) is
>10%
, it f
orce
s th
e st
roke
det
ectio
n m
argi
n so
th
at it
’s th
e sa
me
than
the
slow
-dow
n.
1....
......
......
..255
(m
otor
s w
ith e
ncod
er)
0%…
......
......
100%
(m
otor
s w
ithou
t enc
oder
)
Oper
ator
s fo
rce
adju
stm
ent a
t stro
ke a
rriv
al -
If =
0, s
ettin
g of
f (th
e fo
rce
valu
e on
the
stro
ke is
cal
cula
ted
auto
mat
ical
ly) -
If ≠
0,
indi
cate
s th
e va
lue
(exp
ress
ed in
% o
f the
max
val
ue )
of th
e fo
rce
exer
ted
on th
e st
roke
.0%
tot…
......
......
......
......
...10
0%to
t
“Ene
rgy s
avin
g” m
ode:
If=1
afte
r 10s
ec o
f ina
ctiv
ity, t
he c
ontro
l pan
el t
urns
the
24V
outp
uts
and
the
disp
lay o
ff th
at w
ill b
e tu
rned
on
at fi
rst c
omm
and
rece
ived
(use
reco
mm
ende
d ba
ttery
-pow
ered
and
/ o
r sol
ar p
anel
).•
000
: “En
ergy
sav
ing”
not
act
ive
• 0
01: “
Ener
gy s
avin
g” a
ctiv
e
31
TYPE 01
OPERATING PARAMETERS
Elec
tric-
lock
out
put o
pera
ting:
If=0
“boo
st” o
utpu
t for
ele
ctric
-lock
art
.110
pow
er s
uppl
y, If=
1 24
V ou
tput
con
trolle
d by
the
ELOC
K_IN
inpu
t as
puls
ed m
ode,
If=2
24V
outp
ut c
ontro
lled
by th
e EL
OCK_
IN in
put a
s st
ep-b
y-st
ep m
ode,
If=3
ele
ctro
-bra
ke o
utpu
t for
no
t sel
f-loc
king
ope
rato
rs, I
f=4
24V
outp
ut fo
r ele
ctric
-lock
pow
er s
uppl
y via
an
exte
rnal
rela
y, If=
5 24
V ou
tput
for e
lect
ro-m
agne
ts
pow
er s
uppl
y fo
r ba
rrie
rs, I
f>5
24V
outp
ut c
ontro
lled
by t
he E
LOCK
_IN
inpu
t as
tem
poriz
ed m
ode
(the
set
valu
e in
dica
tes
the
switc
h-of
f del
ay in
sec
onds
).
• 0
00: “
Boos
t” o
utpu
t for
ele
ctric
-lock
art
.110
pow
er s
uppl
y•
001
: “24
V p
ulse
out
put m
ax 5
W•
002
: “24
V s
tep-
by-s
tep
outp
ut m
ax 5
W
• 0
03: “
Elec
tro-b
rake
out
put f
or n
ot s
elf-l
ocki
ng o
pera
tors
•
004
: “Ou
tput
for e
lect
ric-lo
ck p
ower
sup
ply
via
an e
xter
nal r
elay
•
005
: “ou
tput
for e
lect
ro-m
agne
ts p
ower
sup
ply
for b
arrie
rs
• >
005:
“24
V te
mpo
rized
out
put m
ax 5
W(6
sec…
……
……
…25
5sec
)
Run
dire
ctio
n in
vers
ion:
If=
1 au
tom
atic
ally
rev
erse
s th
e ou
tput
s op
en/c
lose
of
the
oper
ator
s an
d an
y op
enin
g/cl
osin
g lim
it sw
itche
s in
puts
, avo
idin
g ha
ving
to m
anua
l cha
nge
the
wiri
ng w
hen
inst
allin
g th
e op
erat
or in
an
inve
rted
pos
ition
.•
000
: “St
anda
rd in
stal
latio
n”•
001
: “In
vert
ed in
stal
latio
n”
Mul
tiplie
r ope
ratio
ns-c
ount
er: M
ultip
ly th
e nu
mbe
r of o
pera
tions
afte
r whi
ch th
e to
tal o
pera
tions
-cou
nter
will
be
upda
ted.
To v
iew
the
valu
es, r
efer
to th
e se
ctio
n “V
isua
lisat
ion
of in
puts
and
ope
ratio
ns-c
ount
er s
tatu
s”.
• 0
00: “
x100
• 0
01: “
x100
0•
002
: “x1
0000
• 0
03: “
x100
000
Mai
nten
ance
Ope
ratio
ns-c
ount
er: i
f =
0 re
set
the
coun
ter
and
disa
bles
the
inte
rven
tion
requ
est
, if>
0 in
dica
tes
the
num
ber
of o
pera
tions
(x
500)
to
be m
ade
befo
re t
he c
ontro
l pan
el e
xecu
tes
a 4
seco
nd a
dditi
onal
pre
-flas
h to
indi
cate
the
nee
d of
m
aint
enan
ce.
i.g.:
If P0
65 =
050
, ope
ratio
ns n
umbe
r = 5
0x50
0 =
2500
0 op
erat
ions
War
ning
: Bef
ore
you
set a
new
val
ue o
f the
cou
nter
-man
oeuv
res
mai
nten
ance
, the
sam
e m
ust b
e re
set b
y se
tting
P06
5= 0
and
on
ly la
ter P
065
= “n
ew v
alue
”.
• 0
00: “
Requ
est M
aint
enan
ce d
isab
led
• >
000:
“N
umbe
r of o
pera
tions
(x 5
00) f
or re
quire
d m
aint
enan
ce(1
......
......
......
......
......
.....2
55)
Sele
ctio
n of
ope
ratin
g fla
shin
g lig
ht o
utpu
t: If=
0 in
term
itten
t flas
hing
ligh
t out
put;
If=1
Fixe
d fla
shin
g lig
ht o
utpu
t (fo
r flas
hing
ligh
ts w
ith in
term
itten
t int
erio
r circ
uits
).•
000
: “in
term
itten
t flas
hing
ligh
t out
put
• 0
01: “
fixed
flas
hing
ligh
t out
put
SAFE
TY 1
Oper
atio
n of
the
SFT
inpu
t: if
= 0
safe
ty e
dge
alw
ays
enab
led,
if =
1 s
afet
y ed
ge e
nabl
ed o
nly
whi
le c
losi
ng, i
f = 2
sa
fety
edg
e en
able
d on
ly w
hile
clo
sing
and
bef
ore
any
mov
emen
t, if
= 3
safe
ty e
dge
enab
led
only
whe
n op
enin
g, if
=
4 sa
fety
edg
e en
able
d on
ly w
hile
ope
ning
and
bef
ore
any
mov
emen
t; as
for t
he o
bsta
cle
dete
ctio
n w
ith in
tern
al
anti-
crus
hing
sen
sor,
also
the
activ
atio
n of
the
inpu
ts S
FT1
and
SFT
2 ca
uses
the
com
plet
e or
par
tial r
ever
sal a
s se
t by
P05
5 (d
urat
ion
of in
vers
ion
on o
bsta
cles
whi
le o
peni
ng, a
nd P
056
(dur
atio
n of
reve
rsal
on
obst
acle
whi
le c
losi
ng)
• 0
00: “
safe
ty e
dge
alw
ays
enab
led
• 0
01: “
safe
ty e
dge
enab
led
only
whi
le c
losi
ng•
002
: “sa
fety
edg
e en
able
d on
ly w
hile
clo
sing
and
bef
ore
any
mov
emen
t•
003
: “sa
fety
edg
e en
able
d on
ly w
hen
open
ing
• 0
04: “
safe
ty e
dge
enab
led
only
whi
le o
peni
ng a
nd b
efor
e an
y m
ovem
ent
SAFE
TY 2
Del
ay o
n lim
it sw
itch
dete
ctio
n: th
e op
erat
ion
is s
topp
ed a
fter 1
,5 s
ec fr
om li
mit
switc
h de
tect
ion.
Whe
n du
ring
this
del
ay a
sto
p is
det
ecte
d, th
e op
erat
or is
sud
denl
y st
oppe
d•
000
: “lim
it sw
itch
dela
y di
sabl
ed•
001
: “lim
it sw
itch
dela
y en
able
d
Adju
stm
ent o
f acc
eler
atio
n du
rabi
lity
War
ning
: if s
oft s
tart
is a
ctiv
ated
, the
acc
eler
atio
n is
dea
ctiv
ated
indi
pend
ently
from
P07
0 va
lue.
• 0
00: “
acce
lera
tion
deac
tivat
ed (i
t run
s an
acc
eler
atio
n of
min
imum
dur
abili
ty,
alm
ost i
mpe
rcep
tible
)•
00X
: “ad
just
s th
e ac
cele
ratio
n du
rabi
lity
at 1
,5 s
ec (X
*6 m
s)
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
Unus
ed p
aram
eter
32
Exclusive Australian Distributor
Customer Service (03) 9364 8288
See downee.com.au for your state office
Tech Support 1800 241 733 [email protected]
downee.com.au
deasystem.com