PERSPECTIVE VIEW, TABLE OF CONTENTS
TOILET DETAILS
GROUND FLOOR PLAN SECOND FLOOR PLAN
REFLECTED CEILING PLAN CROSS SECTIONRIGHT SIDE ELEVATION
SCHED. OF DOORS & WINDOWS RAMPDETAILS, EAVES DETAIL, SUN BREAKERDETAIL DAMP PROOFING DETAIL, BALCONYRAILING DET.ROOF PLAN, LONGITUDINAL SECTION
FRONT ELEV., REAR ELEV.
STAIR & HANDRAIL DETAILS
PERSPECTIVE VIEW & TABLE OF CONTENTSA-1
A-2
A-3
A-4
A-8
A-5
A-6
A-7
SCHEDULE OF SLABROOF DECK FRAMING PLAN
DET. OF FOOTING, TIE BEAM & COLUMNDET. STAIR ON GRADE, RAMP & STAIR
S-1
S-2
FOUNDATION PLAN, 2ND FLOOR FRAMINGPLAN
S-3
S-4 TRUSS DIAGRAM, SCHEDULE OFBEAM DETAILS OF STEELCONNECTION
PERSPECTIVE VIEW1
A-1 SCALE : N T S
P-1 SEWER SYSTEM LAYOUT, LEGEND,DESIGN CRITERIA, NOTES
P-2 WATER & DRAINAGE SYSTEM LAYOUT,SEPTIC TANK, CATCH BASIN, DRAIN PIT,& LEACHING FIELD DETAILS
E-1 GENERAL NOTES, LEGEND, LOADSCHEDULE, RISER DIAGRAM, SINLEDIAGRAM
E-2 POWER LAYOUT (GROUND & SECONDFLOOR)
E-3 LIGHTING LAYOUT (GROUND & SECONDFLOOR)
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-18MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
SANITARY
ELECTRICAL
STRUCTURAL
ARCHITECTURAL
TABLEOF
ENGINEER/BUILDING OFFICIALOFFICE OF THE CITY/MUNICIPAL
REPUBLIC OF THE PHILIPPINES
MECHANICAL
ELECTRICAL
SANITARY
CONTENTS
STRUCTURAL
ARCHITECTURAL
LAND USE & ZONING
LINE & GRADE
DISTRICT/CITY/MUNICIPALITY
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
GROUND FLOOR PLAN1
A-2
GROUND FLOOR PLAN
SECOND FLOOR PLAN
SECOND FLOOR PLAN2
A-2 SCALE : 1 : 100M
C O R R I D O R
UP UP
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
19
18
7000
2500
B
C
675
A
1
W-1WF1
dn.
4500
CONCRETE SUNBREAKER4500
9000
4500
2 3 4
5
C O R R I D O R
C O R R I D O R
UP
RAMPUP
4500
W-3
STO.
D-3
D-5
D-4
HEFL3
D-2
UD
SIN
K C
OU
NTE
R
1500
900
1500600 2502000
4450
200x200mm VITRIFIEDUNGLAZED FLOOR TILES
11
2
A-3
6
A-6
- 100mm THK. CHB w/200X200mm VITRIFIED WALL TILES ( GLAZED )
- 100mm THK. CHB PLAIN CEMENT PLASTER w/50mmØ G.I. PIPE HANDRAIL PAINT FIN.
- 150mm THK. CHB w/200X200mm VITRIFIED WALL TILES ( GLAZED )
FLOORS :
WALLS :
- 200X200 VITRIFIED FLR TILES( UNGLAZED )
- PLAIN CEMENT FLOOR ROUGH
- PLAIN CEMENT FLOOR FINISH
SCHEDULE OF FINISH
WITH GROOVES
- 150 MM THK. CHB W/ PLAINCEMENT PLASTER FIN (PAINT)
WF4
WF3
WF2
WF1
FL2
FL1
FL3
4500
WF1W-1
LANDING
DN.
CONCRETESUNBREAKER (SEEDETAIL)
600
FDFD
11
1A-3
CHALKBOARD
W-2
FL1
FL1
W-2D-1 D-1
W-1
WF1
FL1
CLASSROOM
W-1
WF1
CHALKBOARD
DEP.25mm
DEP.25mm
CHALKBOARD
W-2
FL1
FL1
W-2D-1 D-1
W-1
WF1
FL1
CLASSROOM
W-1
WF1
CHALKBOARD
DEP.25mm
DEP.25mm
CHALKBOARD
W-2
FL1
FL1
W-2D-1 D-1
W-1
WF1
FL1
CLASSROOM
W-1
WF1
CHALKBOARD
DEP.25mm
DEP.25mm
CHALKBOARD
W-2
FL1
FL1
W-2D-1 D-1
W-1
WF1
FL1
CLASSROOM
W-1
WF1
CHALKBOARD
DEP.25mm
DEP.25mm
WF1
C O R R I D O R
7000
B
2500
C
1
675
A
UP
D-4
D-4
FL3
SHE
D-3
SLOPSINK
D-5
W-3
D-2
STO.
RAMPUP
4500
SIN
K C
OU
NTE
R
SD
1500 6002250
900
900
1500
3300
2103 2397
1475
5150
CONCRETE
SUNBREAKER
200x200mm VITRIFIED
FLOOR TILES (UNGLAZED)
1
A-5
4500 4500
9000
1
2 3 4
W-2W-2D-1 D-1
W-1 W-1
WF1
CLASSROOM
FL1
FL1
DEP.25mm
DEP.25mm
W-2W-2D-1 D-1
W-1 W-1
WF1
CLASSROOM
FL1
FL1
DEP.25mm
DEP.25mm
W-2W-2D-1 D-1
W-1 W-1
WF1
CLASSROOM
FL1
FL1
DEP.25mm
DEP.25mm
W-2W-2D-1 D-1
W-1 W-1
WF1
CLASSROOM
FL1
FL1
DEP.25mm
DEP.25mm
SCALE : 1 : 100M
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-28MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
SECOND FLOOR REFLECTED CEILING PLAN1
A-3 SCALE : 1 : 100M
1000
1000
2500
7000
c
b
A
A-6
REFLECTED CEILING PLAN, CROSS SECTION & RIGHT SIDEELEVATION
W-1
CLASSROOM
CLASSROOM
150mm THK. CHB WALLPLASTER PAINT FIN.
CORRIDOR
W-23
A-3
2500
538
3200
EXPOSE CEILINGUNDERSLAB PAINT FINISH
GROUND FLOOR LEVEL
SECOND FLOOR LEVEL
FIN. GRD. LN.
3200
TOP OF ROOF BEAM
TOP OF TRUSS
1000 1000
SEE TRUSS DETAIL
9500
7000
A CB2500
50mm GA# 40G.I. PIPEHANDRAIL
W-1 W-2 3A-3
6725
325
1
3
GA. 26 PLAIN G.I. SHEETGUTTER ON 12x300mmFIBER CEMENT FASCIABOARD (PAINT FINISH)
150mm THK. CHB PLAINPLASTER PAINT FIN.
1000
2500
1000
GROUND FLR. LVL.
3200
325
6725
1
A-3
NAT. GRD. LN.
3200
SECOND FLR. LVL.
TOP OF ROOF BEAM
32mm Ø G.I. PIPEHANDRAIL WITH 32mmØVERT. SUPPORT @300mmO.C. (PAINT FINISH)
1 : 100M
RIGHT SIDE ELEVATIONSCALE :
2500
9500
C
APEX LINE OF TRUSS
7000
B
GA. 26 CORR. G.I. SHEETROOFING (PAINT FINISH)
A
CONCRETE SUNBREAKER (SEE
DETAIL)
LEFT SIDE ELEVATION
GA. 26 CORR. G.I.SHEET ROOFING(PAINT FINISH)
32mm Ø G.I. PIPEHANDRAIL WITH 32mmØVERT. SUPPORT @300mmO.C. (PAINT FINISH)
150mm THK. CHBPLAIN PLASTERPAINT FIN.
GA. 26 PLAIN G.I. SHEETGUTTER ON 12x300mmFIBER CEMENT FASCIABOARD (PAINT FINISH)
1000
CB2500
A7000
9500
APEX LINE OF TRUSS
1 : 100MSCALE : A-34
6725
GROUND FLR. LVL.
3200
NAT. GRD. LN.
3200
SECOND FLR. LVL.
325
1000
2500
TOP OF ROOF BEAM
6mm THK. ORD PLYWOOD CEILINGw/6mm GROOVE ON 50x50mm CLEILINGJOISTS (PAINT FIN.)
LIGHTING FIXTURE
6mm THK. MARINE PLYWOOD CEILINGw/GROOVE ON 50x50mm CEILING JOISTS(PAINT FIN.)
CEILING VENT. (SEE DETAIL)
GA.26 PLAIN G.I. GUTTER ON12x300mm THK. FIBERCEMENT FASCIA BOARD
9000
4500 4500
2 3
4500600
19000
4500 4500
4 59000
4500 4500
6 79000
4500 4500
8 9 10
4500 600
11
CROSS SECTION1
A-3 SCALE : 1 : 100M
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-38MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
6725 SECOND FLOOR LEVEL
NAT. GRD. LN.GROUND FLOOR LEVEL
3200
325
3200
REAR ELEVATION1 : 100M
2
A-4 SCALE :
FRONT ELEV. REAR ELEV.
APEX LINE OF TRUSS
TOP OF ROOF BEAM
2500
1 : 100M
FRONT ELEVATIONSCALE : A-4
1
W-1
D-2
600 4500
6725 SECOND FLOOR LEVEL
NAT. GRD. LN.GROUND FLOOR LEVEL
3200
325
3200
APEX LINE OF TRUSS
TOP OF ROOF BEAM
2500
32mmØ G.I. PIPE GRAB BAR
w/32mmØ G.I. PIPE RAILING
@300mm O.C.
100mm THK. CHB w/ 50mmØ
G.I. PIPE HANDRAIL PAINT
FIN. (SEE DETAIL)
GA#26 G.I. SHEET CORR. ROOFING
PAINT FIN.
1
W-2 D-1
W-2 D-1
4500
9000
4500
W-2D-1
W-2D-1
2 3 4
W-1
D-2
6004500
32mm Ø G.I. PIPEHANDRAIL WITH 32mmØVERT. SUPPORT @300mm O.C. (PAINTFINISH)
100 MM THK. CHBRAILING W/50mm ØG.I. PIPE RAILING
GA. 26 CORR. G.I.SHEET ROOFING(PAINT FINISH)
GA. 26 PLAIN G.I.GUTTER ON12x300mm FIBERCEMENT FASCIA BD.(PAINT FINISH)
11
W-1 W-1
W-1 W-1
4500
9000
4500
10 9 8
W-3
W-1
6004500
1
W-2
4500
9000
4500
D-1W-2
D-1W-2D-1
W-2D-1
W-2
D-1 W-2
D-1 W-2 D-1
W-2 D-1
4500
9000
4500
57 6 7 8
7 6 5 4 3 2
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-48MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
10200
2500
3200
NAT. GRD. LN.GROUND FLOOR LEVEL
325
3200
SECOND FLOOR LEVEL
LONGITUDINAL SECTION2
A-3SCALE : 1 : 100M
LONGITUDINAL SECTION
ROOF PLAN
APEX OF TRUSS
600
THIRD FLOOR LEVEL
ROOF PLANSCALE : A-3
1
1 : 100M
9000
4500
7000
2500
4500
9000
1 32
4500 4500
9000
4500
4 5
4500
6 7
4500
8 9 10 11
4500600
9000
4500 4500 600
LN. OF STRUCTURE
RD RD RD RD RD RD
RD RD RD RD RD RDRD
1000
1000
B
C
A
SHE
LANDING
W-1
W-3
4500
1 2
EXPOSED UNDER SLAB CEILINGPAINT FINISH
HE
LANDING
W-1
W-3
6004500
11
GA. 26 PL. G.I. SHT. GUTTERON 12x300mm FIBERCEMENT FASCIA BD. PAINTFIN.
GA. 26 CORR. G.I. SHEETROOFING PAINT FIN.
GA. 26 PL. G.I. SHT. RIDGEROLL PAINT FIN.
GA. 26 PL. G.I. SHT.FLASHING ON 12x300mmFIBER CEMENT FASCIABOARD PAINT FIN.
45009000
4500
3 4
1
5
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
W-1CLASSROOMW-1
11500
45009000
4500
5 6
2
6
45009000
4500
7 8
3
7
45009000
4500
9 10
4
8
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-58MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
SCHED. OF DOORS & WINDOWS
RAMP DETAILS, EAVES DETAIL, SUN BREAKER DETAIL
FR. QUARTER-CMOULDING CEILING
CONTACT TO CONC.WALL
6mm THK. ORD. PLYWD.CEILING (PAINT) ON50x50mm CLG. JST.
@600mm OC BW
6mm THK. MARINEPLYWD. CEILING(PAINT) ON 50x50mmCLG. JST. @600mm OCBW
SEE TRUSS DET.
CONC. BEAM
150 100
100X100 CONCRETE
2000
SKIRTING
32 mm Ø G.I PIPE VERTICALSUPPORT @ 300mm ON CENTERPROVIDE 12mmØ STEEL DOWELS(PAINT FIN.)
32mmØ G.I. PIPE HANDRAILw/32mmØ VERT. SUPPORT@300mm O.C. (PAINT FIN.)
TOTAL RUN OF RAMP
C O R R I D O R
9000
5000
B
175
1400
C
2800
2400
5150NON-SKID PLAINCEMENT FLOOR
FINISH w/GROOVELINES
3600
RAMP UP
65
3
A-4
A-4
4
300
325
6 25
1250 12
25x25mm WOOD VENT.PROVIDE INSECT SCREEN
6mm THK PLYWOOD CEILINGON 50x50mm CEILING JOIST@600mm OC. BW (PAINT FIN.)
FR.25x75mmVENT FRAME
(PAINT FIN.)
50
300
FR. 25x75mm WOODFRAMEPAINT FIN.
1175
25x25mm WOOD VENT
11
A-6
PROVIDE INSECT SCREEN
A-4
GRAVEL BEDDING
CONCRETE HOLLOWBLOCKSCONCRETE SLABPOLYETHYLENE SHEET DAMP PROOFING
2-32mmØ G.I. PIPE HANDRAILw/32mmØ VERT. SUPPORT @300mm
O.C.(PAINT FIN.)
SCALE 1:50 M
DET. ELEVATION OF RAMP
NON-SKID PLAIN CEMENTFLOOR FINISH
w/GROOVE LINES
700
900
200 200
700
300
1200
900
3
A-6
2
CEILING VENT (SEE DETAIL)
1000
C-PURLIN (SEE STRUC'L DETAIL)
SAG ROD SEE STRUCTURAL DETAIL
2A
A-1
2A
A-1
6mm THK. MARINE PLYWOOD CEILING ON50x50mm CEILING JOIST @600mm BW
75mmØ PVC DOWNSPOUT PAINT FINISH
BASKET STRAINER
GA#26 GI STRAP
GA#26 G.I. GUTTER ON 12x300mm FIBERCEMENT FASCIA BOARD PAINT FIN.
ROOFBEAM
6mm THK. ORD.PLYWOOD CEILING W/
6mm GROOVE ON50x50mm CEILING JOIST
@600mm BW (PAINTFIN.)
TOP CHORD SEE STRUCTURAL DETAIL
38mmØ TEKSCREW
NON-SKID PLAIN CEMENTFLOOR FIN. w/ GROOVELINES
12mMØ STEEL DOWELEMBEDD IN CONC.
900
700
100
2-32mmØ G.I. PIPE HANDRAILw/32mmØ VERT. SUPPORT@300mm OC (PAINT FIN.)
200
6mm THK. MARINE PLYWOODCEILING ON 50x50mm CEILINGJOIST @600mm BW
75mmØ PVCDOWNSPOUT PAINTFINISH
GA#26 GI GUTTER PAINT FIN.
GA#26 GI STRAP
12x300mm FIBER CEMENT FASCIABOARD FIX W/METAL SCREW ON STL.FRAME PAINT FINISH
COPPER RIVET
38mmØ TEKSCREW
BASKET STRAINER
20x20X2mm ANGULAR BAR FORFASCIA BOARD FRAME COATEDWITH PRIMER
GA#26 CORR. G.I. ROOFINGSHT. PAINT FIN.
700
HOLLOW CORE FLUSH TYPE SWING DOORORDINARY COMPLETE W/ HARDWARESAND ACCESSORIES
1000
TANGUILE PANEL DOOR ON 50X150 MMTHK. YACAL/GUIJO JAMB W/ FIXEDCLEAR GLASS TRANSOM COMPLETEWITH HARDWARES AND ACCESSORIES
2100
2400
D-1
CLASSROOM
FFL
300
1800
(VAR)
2100
TOILET
HOLLOW CORE FLUSH TYPE SWINGDOOR W/ MARINE PLYWOOD FACINGINSIDE AND ORDINARY OUTSIDECOMPLETE W/ HARDWARES ANDACCESSORIES
D-2 D-4
900
JALOUSIE WINDOWS WITH CLEAR GLASSBLADES ON STANDARD ALUMINUM CASINGAND FIXED CLEAR GLASS TRANSOM ON50X150 YACAL/GUIJO JAMB COMPLETE WITHHARDWARES AND ACCESSORIES
2 EQUAL PARTS = 1225
900
FFL
±1240
14-BLADES
2400
260
1200
1500
300
D-5
STO.
W-1
TOILET (CUBICLE)
SWING DOOR ON 50X100YACAL/GUIJO DOOR JAMBCOMPLETE WITH HARDWARESACCESSORIES
600
±1240
14-BLADES
2400
JALOUSIE WINDOWS WITH CLEAR GLASSBLADES ON STANDARD ALUMINUM CASINGAND FIXED CLEAR GLASS TRANSOM ON50X150 YACAL/GUIJO JAMB COMPLETE WITHHARDWARES AND ACCESSORIES
900
W-2
4 EQUAL PARTS = 2500
260
17652400
JALOUSIE WINDOWS WITH CLEAR GLASSBLADES ON STANDARD ALUMINUMCASING ON 50X150 YACAL/GUIJO JAMBCOMPLETE WITH HARDWARES ANDACCESSORIES
W-3
4 EQUAL PARTS = 2500
±635
7-BLADES
1500
750
TOILET (DISABLED)
LOUVER TYPE DOUBLE SWING DOORCOMPLETE W/ HARDWARES ANDACCESSORIES PROVIDE KICK PLATE
300
D-3
STAINLESSSTEEL KICKINGPLATE
900
DET. PLAN OF RAMPSCALE : A-6
2
1 : 50M
DETAIL PLAN (VENT.)SCALE : A-6
10
1 : 10M
SPOT DETAILSCALE : A-6
2A
1 : 5M
SPOT DETAIL (CORNER CLG.)SCALE : A-6
9
1 : 10M
SECTION DEATIL (VENT.)SCALE : A-6
11
1 : 5M
CONCRETE SUNBREAKER DET.SCALE : A-6
12
1 : 10M
BEAM REBARS SEESTRUCTURAL DETAIL
100
12x12mm GROOVE
675
10mmØ @250mm ONCENTER
100
SPOT DETAIL (EAVES)SCALE : A-6
8
1 : 10M
SECTION DETAIL (EAVES)SCALE : A-6
7
1 : 10M
DOORS & WINDOWS SCHEDULESCALE : A-6
1
1 : 50M
DAMP PROOFING DET.NOT A-6
6
SCALETO
DETAIL SECTIONSCALE : A-6
2A
1 : 10M
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-68MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
STAIR DETAILS
HANDRAIL DETAILS
ANCHOR @R.C.STAIR
19mm SQUARE BARWELDED TO G.I. PIPEHANDRAIL @146mmO.C.
50mm%% G.I. PIPESCH. 40 PAINT FIN.
3494
9344
16 T
RE
AD
S @
292
mm
EA
CH
= 4
672m
m
DN
12
11
16
14
13
1718
19
15
10
50mmØ G.I. PIPE SCH. 40w/19mm SQ. BAR @146mmON CENTER PAINT FIN.
9000
W-1
LANDING
PLAIN CEMENT STEELTROWELL FIN.
B
A
(SECOND FLOOR TO GROUND FLOOR)
SCALE :
14000
5000
4400 4400
200
1:50 mts
DETAIL PLAN OF STAIRA-7
2
A-7
9
A-7
35 6
A-7
8
7A-7
250
1460
TYPICAL
6A-74
498
4248
250
LANDING
TYP
ICA
L
±842
12x12x2mm FLAT BARSTRAP @600mm O.C.
2x25x25mm ANGULARBAR NOSING @STEP
3368
500
500
19mm SQ. BAR ANCHOREDTO THE WALL (PAINT FIN.)
1993
50mmØ SCH. 40 G.I.PIPE PAINT FIN.
10071007
146
50mmØ G.I. PIPE SCH. 40PAINT FIN.
19mm SQUARE BAR WELDTO G.I. PIPE HANDRAIL@146mm O.C.
SECOND F.F.L.
ANCHOR @R.C. STAIR
25x25x2mm ANGULAR BARNOSING
4500
5A-7
19mm SQUARE BARWELDED TO G.I. PIPEHANDRAIL @146mmO.C.
730
TYP
ICA
L
4500
50
50mmØ G.I. PIPE SCH.40 PAINT FIN.
SECOND FLOOR LEVEL
100mm THK CHB RAILINGPLASTER AND PAINT FIN.
50mm G.I.PIPE SCH. 40HANDRAIL w/25mm SQ.
BRACKECT @600mm O.C.PAINT FIN.
200
ELEV.SCALE: 1:50m
700
C
SCALE: 1:20mDETAIL
150
50
C
900m
m F
RO
M T
RE
AD
50
175
19 mm SQUARE BARANCHOR TO THEWALL (PAINT FIN.)
5050mmØ G.I. PIPESCHEDULE 40(PAINT FINISH)
TREAD
19mm SQUARE BARWELD TO G.I. PIPEHANDRAIL @146mmO.C.
50mmØ G.I. PIPESCHEDULE 40(PAINT FINISH)
500
1250
W A
L L
730
A B C
5A-7
10A-7
400 11
±337
9345
LAV
HE
6001200
HCR
800
WC±1800
584
684
109
87
6
16 TREADS @ 292 = 4672
3290 5
43
21 CORRIDOR
399
1401
1800
50mmØ SCH. 40 G.I. PIPE HANDRAILw/19mm SQ. BAR @146mm O.C
90814919
18
292
19
1615
1413
12
CORRIDOR
399
1401
1800
500014000337
2863
W-3
3530
5526
17 RISERS @±168 = 2856
6400
650
NATURAL GRADE LINE
GROUND FLOOR LINE
200x200mm VITRIFIEDGLAZED WALL TILES
6400
2 RISERS @±168
SECOND FLOOR LINE
ROOF LINE
5mm THK. FACIALMIRROR
WC
LANDING
W-1
17
38mmØ STAINLESSSTEEL GRAB BAR
GA#26 GI GUTTER PAINT FIN.
12x300mm FIBER CEMENT FASCIABOARD FIX W/METAL SCREW ON STL.FRAME PAINT FINISH
1800 3000
3702
EXPOSEDUNDERSLAB CEILING
PAINT FIN.
200
1700
2200
B
A
16TR
EA
DS
@ 2
92m
m E
AC
H =
467
2mm14000
9344
100
292
2
(GRD FLOOR TO SECOND FLOOR)
1
UP
4
3
10
8
9
6
5
7
11
12
9A-7
50mmØ G.I. PIPE SCH. 40w/19mm SQ. BAR @146mmON CENTER PAINT FIN.
4656
W-1
19
18
17
16
15
13
14
TOILET
9000
5 6
1800
NOSING DETAILSCALE : A-7
6
1 : 10M
SECTION DETAILSCALE : A-7
4
1 : 20M
HANDRAIL DETAILSCALE : A-7
5
1 : 20M
DETAIL SECTION OF STAIRSCALE : A-7
3
1 : 50MDETAILED PLAN OF STAIRSCALE : A-7
1
1 : 100M
BALCONY RAILING DET.SCALE : A-7
11
AS SHOWN
SPOT DETAILSCALE : A-7
10
1 : 5M
SPOT DETAILSCALE : A-7
8
1 : 5M
CRASH RAILINGSCALE : A-7
7
1 : 20M
SPOT DETAILSCALE : A-7
9
1 : 20M
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-78MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
TOILETS DETAIL
150250200
150
URINAL
FEMALE
SINK
WC
W-3
300
1600
1013
125
2613
2713
CLASSROOM LVL.
TOILET LVL.
LANDING LVL.
2ND FLR. LVL.
50
2688
512
3200
LANDING
4500
21
MALE WC
W-3
300
1600
1013
125
2613
2738
CLASSROOM LVL.
TOILET LVL.
LANDING LVL.
2ND FLR. LVL.
50
2688
512
3200
LANDING
4500
1110
PLAIN CEMENT PLASTER
CERAMIC WALL TILES
200X200 VITRIFIED
PAINT FINISH
( GLAZED )
1750 100 1750100
900
FIN. GRADE LN.
CORRIDOR LVL.
TOILET LVL.25
FIN. GRADE LN.
CORRIDOR LVL.
TOILET LVL.
4258508501175100
SINK COUNTER
SD
800
300
200
800
2500
3mm THK. SOLID WOODFASCIAL MIRROR ON AL.FRAMING
200x200mm VITRIFIED WALLTILES (GLAZED)
800
DET. ELEVATION
DET. SECTION
PLAIN CEM. PLASTEREDPAINT FIN.
PLAIN CEM. PLASTERED
PAINT FIN.
200x200mm GLAZED
WALL TILES
150
DET. PLAN
651
600
3500
200x200mm VITRIFIED
GLAZED TILES
200x200mm VITRIFIED
GLAZED WALL TILES
25
TREAD
450
600
600
450
7000
B
1
A
UP
D-5
D-5
FL3SHE
D-3
SLOP
SINK
D-4
W-3
D-2
STO.
4500
SIN
K C
OU
NTE
R
SD
1500
600
2250
900
900
1500
3300
2103 2397
1800
2
200x200mm VITRIFIEDFLOOR TILES(UNGLAZED)
1550
600
943
LOW PARTITION w/200x200mm VITRIFIEDGLAZED WALL TILES
HCR
4500
W-3
STO.
D-2
D-4
D-5
HE
D-3
FL3
UD
SINK COUNTER
1500
1750
200
150
250
7000
900
1500
2650
450
450
600
600
100
2500
2186
5375
7000
200x200mm VITRIFIEDFLOOR TILES(UNGLAZED)HCR
UP
UR
INA
L
10 11
600 600
240
450240 450
1500
150 250
URINAL
200
150
DET. OF COUNTER SINKSCALE : A-8
5
1 : 20M
MALE TOILET DETAILSCALE : A-8
2
1 : 20M
FEMALE TOILET DETAILSCALE : A-8
1
1 : 20M
DET. SECTION OF MALE TOILETSCALE : A-8
4
1 : 50M
DET. SECTION OF FEMALE TOILETSCALE : A-8
3
1 : 50M
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
NATHANIEL Q. MENDOZA
ARCHITECT III, PFSED-DepED
A-88MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
G-1G-1 G-1G-1
4500
G-3a
4500
S-2
C-3
F-3
C-2
F-2
4500450045004500450045004500
7000
2500
S-1
B
4500450045004500450045004500
BOTHWAYS
SPACED AT 400
WITH Ø10mm
SLAB ON FILL
100mm THICK
TG-2
TG-2
TG-1
G-6
G-6
G-6
G-6
G-3G-3G-3G-3G-3
G-2G-2G-2G-2G-2
G-1G-1
C-1
F-1
G-6 S-2S-2S-2S-2S-2
1:100 M.SCALE :
2ND FLOOR FRAMING PLAN
C
B
A
1110654321
1:100 M.SCALE :
FOUNDATION PLANS-1
A
TG-3 TG-3 TG-3 TG-3 TG-3 TG-3 TG-3 TG-3
TG-3
TG-3
S-1
B-1
S-1
S-1
B-1
S-1
S-1
B-1
S-1
S-1
B-1
S-1
S-1
B-1
S-1
G - 7
G - 7
G - 7
G - 7
G - 7
2500
7000
41 2 3 5 6
C
B
A
2ND FLOOR FRAMING PLAN
FOUNDATION PLAN
4500
TG-2
7
TG-3
G-1
4500
G-6
G-3
G-2
S-2
S-1
B-1
S-1
G - 7
7
G-2
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
TG-3
G-1
G-3a
S-2
G-6
G - 7
STAIR WELL
S-2 B-2
CB-1
G-2
S-1
B-1
S-1
G-6
G - 7
8
TG-2
8
TG-1
TG-1
TG-1
TG-1
TG-1
S-3
B
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
C-3
F-3
TG-2
TG-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-2
F-2
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
C-1
F-1
G-5
G-4
4500
TG-3
TG-3
TG-3
9
C-3
F-3
C-2
F-2
C-1
F-1
4500
G-3
G-2
G-1
S-2
S-1
B-1
S-1
G-6
11109
4500
G-1
G-3a
S-2
STAIR WELL
S-2B-2
CB-1
G-2
G-5
G-4
TG-2
TG-1
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
S-14MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
ROOF DECK FRAMING PLANSCALE :
TYPICAL SLAB ELEVATION
MIDSPAN
S C H E D U L E OF S L A B SREBAR SPACING ALONG SHORT DIRECTION
LEVEL
LEVEL
FLOOR
SECOND
REBAR
S-2
SLAB
MARK
S-1
100
100
NESS
THICK-
in mm
200
300
LEFT SUPPORT
TOP
10Ø
SIZE
10Ø
-
TOP
-
300
BOTT.
300
in mmin mm
B
S-2
S-2
A
REBAR SPACING ALONG LONG DIRECTION
REBAR
BOTT.
300
300
SIZE
10Ø
10Ø
300
BOTT.
300
TOP
300
RIGHT SUPPORT
200 300-250 300
MIDSPAN
-300
TOPBOTT.
300
TOP
LEFT SUPPORT
300
BOTT.
in mmin mm
TWO-WAY
TWO-WAY
REMARKS
250 300
RIGHT SUPPORT
BOTT.
300300
TOP
1:100 M.
BOTTOM BAR
TOP BAR
L1/6
L1
L1/3TOP BAR
L2/5L1/5 BOTTOM BAR
L2/3L1/3
L2
SCHEDULE OF SLAB
ROOF DECK FRAMING PLAN
45004500 4500
RG-1
RG-1RG-1
2500
RG-2
RG-1
RG-1
RG-1
RG-1
RG-1
RG-1
RG-1
RG-1
RG-2
RG-1
RG-2
T-1
RG-2
RG-1
T-1
4500 4500
RG-1
RG-1
RG-1
RG-2
RG-1
41 2 3
C
B
A
7000
T-1
T-1
T-1
11
RG-1
RG-1
WITH Ø10 SAGRODS @ MIDSPAN
SPACED @ 750 mm O.C
LC-120x40x20x2.0 PURLINS
BRACINGS
Ø12mm CROSS
4500
RG-1
RG-1
RG-1
RG-1
RG-2
T-1
RG-2
RG-1
T-1
4500
65
RG-1
RG-1
4500
RG-1
RG-1
RG-1
RG-2
RG-1
T-1
74500
RG-1
RG-1
RG-1
RG-1
RG-2
T-1
10
RG-1
RG-2
T-1
8
RG-1 RG-1
4500
RG-1
RG-1
RG-1
RG-1
RG-2
T-1
9
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
S-24MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
DETAIL OF TIE BEAMNTS
TYPICAL BEAM ELEVATIOND
S-3
S-3
E TYP. FOOTING DETAILSCALE NTS
S-3SCALE
A
TIE BEAM
(SEE SCHEDULE)
100
NGL
PLAN
W
L
100
X-BARS
L
SECTION
NGL
t
D
Y-BARS
100 mm THICK
GRAVEL BEDDING
X-BARS
Y-BARS
D
2D
L1
ONLY IN THIS PORTION
LAP SPLICES ARE ALLOWED
2-Ø12mm SIDE BARS
L2
L2/5
2D
L2/3
L2/5
2D
L2/3
ONLY IN THIS PORTION
LAP SPLICES ARE ALLOWED
L3
L2/5
L3/3
2D
L3/6
2D
L3/3
DET. OF FOOTING, TIE BEAM & COLUMN
DET. STAIR ON GRADE, RAMP & BEAM
DETAIL OF STAIR ON GRADE1 : 25M
S-3SCALE
B DETAIL OF RAMPS-3
SCALE
C
1 : 50M
WIDTH
S C H E D U L E O F F O O T I N GFOOTING DIMENSIONS (mm)
(W)
2100
MARK
FOOTING
LENGTH
(L)
F-3
F-2
F-1
2300
1400
11 - 16mmØ 1500 300 SQUARE FOOTINGSQUARE FOOTING
12 - 16mmØ
DEPTH
(D)
1500
1500
300
300
(t)
ThicknessBAR YBAR X
REINFORCEMENT
SQUARE FOOTINGSQUARE FOOTING
SQUARE FOOTINGSQUARE FOOTING
REMARKS
7 - 16mmØ
2100
2300
1400
11 - 16mmØ
12- 16mmØ
7 - 16mmØ
10 11NOSING BAR
1-Ø10
4-Ø10 CONT. BARS
Ø10 @250
CUT BARS
400
125
100
125
Ø10 SPACED
AS SHOWN
Ø10 @250
MAIN BARS
Ø10 @250
CUT BARS
125
Ø10 300mm TEMP
BARS BOTHWAYS
Ø10mm
ROOF DECKLEVEL
2ND FLOOR LEVEL TO
FOUNDATION LEVEL TO
2ND FLOOR LEVEL
LEVEL
MAIN BAR: MAIN BAR:MAIN BAR:
350
150mm TO CENTER
1@50, 8@75, REST @
MAIN BAR:
TIES : Ø10 mm
8-Ø16mm
350
1@50, 8@75, REST @
150mm TO CENTER
8-Ø16mm
TIES : Ø10 mm
350
150mm TO CENTER
1@50, 8@75, REST @
MAIN BAR:
14-Ø20mm
TIES : Ø10 mm
150mm TO CENTER
1@50, 8@75, REST @
350
8-Ø20mm
TIES : Ø10 mm
350
150mm TO CENTER
1@50, 8@75, REST @
MAIN BAR:
12-Ø20mm
TIES : Ø10 mm
350
150mm TO CENTER
1@50, 8@75, REST @
8-Ø20mm
TIES : Ø10 mm
C O L U M N S C H E D U L E
350
350
C-1
350
350
C-2
350
350
C-3
BEAM
DIMENSIONS
G-7
2ND FLOOR LEVEL
250
TG-2BEAM
TIE
300BEAM
STAIR
STB-2
STB-1
TG-3
200
200
300
LEVEL
ROOF
CB-1
B-1
B-2
200
200
200
RG-1
TG-1
RG-2
300
200
200
BEAMFLOOR
LEVEL MARK ( in / mm )
G-2
G-3a
G-4
G-6
G-5
G-3
G-1
b
200
200
200
200
250
200
200
35 1@50, 8@100, REST@20023 6500 5Ø20mm
1@50, 6@100, REST@200
1@50, 6@100, REST@200
1@50, 6@100, REST@200
1@50, 6@100, REST@200
1@50, 8@100, REST@200
1@50, 6@100, REST@200
1@50, 8@100, REST@200
1@50, 6@100, REST@200
1@50, 8@100, REST@200
1@50, 8@100, REST@200
23500 4Ø20mm
4
3
2
500 Ø16mm
Ø16mm400
500 Ø20mm
22
22
2 2
4
4
2
2
3
5
400 Ø16mm
400
400
Ø16mm
Ø16mm
400 Ø16mm
500 Ø20mm
500 Ø16mm
42
22
22
22
22
23
342
4
3
2
4
4
2
2
2
2
4
4
2
2
4
4
2
2
4
2
2
3
2
2
2
2
3
3
S T I R R U P S
Ø10mm
1@50, 6@100, REST@200
1@50, 8@175, REST@300
1@50, 6@100, REST@200
1@50, 6@100, REST@200
1@50, 8@100, REST@200
1@50, 6@100, REST@200
1@50, 6@100, REST@200
(UNLESS NOTED OTHERWISE)
MID SPAN
B E A M S C H E D U L E
S T E E L R E I N F O R C E M E N T S
3
3
2
2
5
3
2
TOP
REBAR
400 Ø20mm
800
400
400
500
400 Ø20mm
Ø20mm
Ø20mm
Ø20mm
Ø20mm
Ø20mm400
h(mm Ø)
LEFT
222
22
22
22
23
22
2 2
TOPBOTTOM
RIGHT
BOTTOM
3
3
5
5
5
3
2
TOP
2
2
2
2
4
2
2
BOTTOM
2
2
3
3
3
2
2
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
S-34MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
A
2500
BOTTOM CHORD
CONNECTION DETAIL
PURLIN CONNECTION DETAIL
CONNECTION DETAIL
S-4
GSCALE
ANCHOR BOLT
1-Ø10mm A-307
SCALE
E
S-4
FULL WELD
SCALE
D
S-4
TOP CHORD
W-2
W-2
SEE TRUSS ANCHORAGE DETAIL
SAG ROD CONNECTION DETAIL
LC-120x40x20x2.0
1 : 5 M
1 : 5 M
L-2.5x2.5x1/4
PURLINS
SCALE
S-4
I
75
75
1 : 10 M
S-3
J
WASHERS @ EACH END
10mmØ SAG ROD WITH
STANDARD NUTS &
120x40x20x2.0mm
STEEL C-PURLINS
±750mm O.C.
HALF TRUSSCONNECTION DETAILSCALE 1 : 10 M
W-1
6-Ø10x200mm LONG
W-2
W-2
SCHEDULE OF TRUSS MEMBERS
CONNECTION DETAILFULL WELD
6mm GUSSET PLATE (TYP.)
KING POST
1 : 5 M
F
S-4SCALE
TOP CHORD
DETAIL OF T-1S-4
6mm GUSSET PLATE (TYP.)TOP CHORD
SCALE
A
W-2
W-1
W-2
W-2
W-2
W-2
W-2
W-2
WEB MEMBERS
DESCRIPTION
TOP & BOT. CHORDSW-1
MARK
W-2
1 : 25 M
2L-2x2x1/4 STRUTE
S-4
W-2
W-2
W-2
W-1
W-2
W-1
W-2
W-2
2"x2"x3/16"
TYPICAL TRUSS
SCALE
ANCHORAGE DETAIL
1 : 5 M
H
S-4
6mm GUSSET PLATE (TYP.)
FULL WELD
1:5 M
2L
QTY
2"x2"x1/4"
SIZE
2L
F
S-4
1000
W-2
W-2
(FROM LANDING TO1 : 25 M
S-4SCALE
O
S-4
Ø10mm @
1 : 25 M
SPOT DETAILSCALE
3-Ø10mm
300mm o.c.TG-3
100
100
100100 100
TRUSS DIAGRAM, DETAIL OF STAIRDETAILS OF STEEL CONNECTION
SPOT DETAILSCALE
STB-2
P
S-41 : 25 M
2ND/3RD FLOOR LEVEL)
CB-1
A
Ø12 @120
SECTION OF STAIR SLAB
STAIR FRAMING PLAN (TYP.)
SCALES-4
M
B
K
S-4 SCALE
Ø16 @200TEMP BARS
1:25 M
1:50 M
B-2
7000
15 TREADS @ 300mm EACH = 4500mm
4500
DC-1
DN
S-2
STB-2DC-1
STAIR SECTION DETAIL
SPOT DETAIL
Ø16 @ 200
N
MAIN BAR
200mm
L
S-4 SCALE
Ø10 @300
200
4-Ø16mm
DC-1
150mm TO CENTER
1@50, 8@75, REST @
TIES : Ø10 mm
200
MAIN BAR:
1:50 M
TG-3
CB-1
GROUND FLOOR LEVEL
G-3aSTB-2
P
S-4
S-4
O
N
S-4
G-2
2ND FLOOR LEVEL
C
S-4
S-4L
S-45 6
Ø12 @300
2-Ø10
STEP BAR
200
2-Ø10
STEP BAR
200mm
Ø10 @300
2-Ø10
STEP BAR
Ø10 @300
200
Ø12@ 125
STEP BARS
Ø12@ 125 TOP
MAIN BARS
4500
22002200
2150
2150
3200
S-4
M
SEE SCHEDULE OF
S-2 (2ND/3RD LVL)FOR DETAIL OF REIN.CB-1
2834
2856
200
292
168
9500
1000 2-SPAN @1250
2500
2-SPAN @1125
2250
4-SPAN @1187.5
4750
1187
±750
SECTION
PLAN
200
50 50
6mm GUSSET PLATE
BOTTOM CHORD
4-Ø12x300mm LONG
ANCHOR STUDS
200x200x10mm
EMBEDED PLATE
50
100
50
200
6mm GUSSET PLATE
BOTTOM CHORD (FULLYWELDED TO BASE PLATED)
4-Ø12x250mm LONG
ANCHOR STUDS
200x200x10mm BASE
PLATE
COLUMN OR BEAM
5050
200
50 50 5050
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
S-44MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
D
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
GENERAL NOTES
SINGLE LINE DIAGRAM
LEGEND
LOAD SCHEDULE
RISER DIAGRAM
- VIBRATING BELL OUTLET
- FIRE ALARM STATION OUTLET
- EXHAUST FAN OUTLET, SINGLE, GROUNDING TYPE
10 AMPS, 250 VOLT WITH MODERN PLATE COVER
10 AMPS, 250 VOLT WITH MODERN PLATE COVER
- DUPLEX CONVENIENCE OUTLET, GROUNDING TYPE
TOTAL
PANELBOARD:
MAIN :
AF
WIRE & CONDUIT SIZEVACKT.
LOAD SCHEDULE
ATPOLEVOLT
DESCRIPTIONNO. LOAD
IL @ 80% D.F. = x 80% x 1.25 =
CIRCUIT BREAKER
230 V
FEEDER:
PROTECTION: 100 AT, 100 AF, 2P, 230 V
2-30mm² THW IN 32mmØ C 54.5 A12540
14680
100AT, 100AF, 2P, 230V
LP
f. FIRE ALARM & VIBRATING BELL - 0.30 M BELOW CEILING LINE
e. PUSH BUTTON OUTLET - 1.20 M ABOVE FINISH FLOOR
d. FIRE ALARM STATION OUTLET - 1.50 M. ABOVE FINISH FLOOR
c. PANELBOARD - 1.50 M ABOVE FINISH FLOOR
b. CONVENIENCE OUTLET - 0.30 M ABOVE FINISH FLOOR.
a. LIGHT SWITCH - 1.20 M ABOVE FINISH FLOOR
MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS :8.
7.
6.
5.
4.
3.
GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL
CODE REQUIREMENT.
ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND
PURPOSE OF USAGE.
ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16 DEEP TYPE WITH FACTORY KNOCKOUTS.
ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THW" UNLESS OTHERWISE INDICATED IN THE
PLAN. THE MINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUIT HOMERUN SHALL BE 3.5mm² AND INSULATED
FOR 600 VOLTS. SMALLEST RACEWAY SHALL BE 15mmØ TRADE/NOMINAL SIZE. I
WIRING METHOD SHALL BE AS FOLLOWS :
a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUIT
b. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT SCH. 40
BRANCH CKT., & AUXILIARY
2.
1.
THE ELECTRICAL SERVICE POWER IS 1-PHASE, 2-WIRE, 230 V AC, 60 Hz.
ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC). THE RULES AND REGULATION OF
THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL
WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER.
GENERAL NOTES
2
DESCRIPTION
LEGEND
F
SYMBOL
- CEILING FAN OUTLET
- 2 x 40 WATTS FLUORESCENT LAMP
- CEILING LIGHT OUTLET
a
cdeS
3W S
S/S
Sab
Sf
S EF
LP
EF
- PANELBOARD
- HOMERUN DIRECT TO PANELBOARD
- CKT. BREAKER, RATING AS INDICATED
- THREE GANG DEVICE SWITCH
- THREE WAY DEVICE SWITCH
- TWO GANG DEVICE SWITCH
- ONE GANG DEVICE SWITCH
- FAN CONTROL SWITCH
- EXHAUST FAN SWITCH
- RACEWAY CONDUIT CONCEALED UNDER FLOOR
- RACEWAY CONDUIT CONCEALED IN CEILING
FA
- PUSH BUTTON
- FIRE ALARM CONTROL PANEL
- ENCLOSED AIR CIRCUIT BREAKER
B
B
F
M
- FIRE ALARM BELL
- SERVICE METER
- SERVICE ENTRANCE
16mmØx2400mm
#14MM² BARE COOPER WIRE
2
4
6
8
10
12
14
1615
13
11
9
7
5
3
1
20
20
20
20
20
20
20
20
PANEL LP
20
20
20
2020
20
20
20
GROUND TERMINAL
COPPERWELD
GROUND ROD
150AT, 225AF, 2P, 230V AC
SINGLE LINE DIAGRAMNOT TO SCALE
1 CONVENIENCE OUTLET - 7x180w1260 230 2 20 50 3.35mm² THW IN 15mmØ C
10 S P A R E 1500 230 2 20 50
2 CONVENIENCE OUTLET - 4x180w720 230 2 20 50 3.35mm² THW IN 15mmØ C
3 CONVENIENCE OUTLET - 7x180w1260 230 2 20 50 3.35mm² THW IN 15mmØ C
4 CONVENIENCE OUTLET - 4x180w720 230 2 20 50 3.35mm² THW IN 15mmØ C
LIGHTING OUTLET 13x100w
6 LIGHTING OUTLET 15x100w 1500 230 2 20 50 3.35mm² THW IN 15mmØ C
7 LIGHTING OUTLET 11x100w 1100 230 2 20 50 3.35mm² THW IN 15mmØ C
8 LIGHTING OUTLET 15x100w 1500 230 2 20 50 3.35mm² THW IN 15mmØ C
IN RSC
2-3.5mm² THW15mmØ
15mmØ
2-3.5mm² THWIN RSC
IN RSC
3-3.5mm² THW15mmØ
32mmØ
2-32mm²THW
32MMØ
OVERHEAD SERVICE ENTRANCE
CONNECTED TO 220V AC, 1Ø, 2 WIRE, 60Hz FITTED WITH
TYPE "F" CONDULET
TO SIMILAR OUTLET
@ SECOND FLOOR
& THIRD FLOOR 2ND FLOOR LINE
BUILDING WALL
B
TO NEAREST C.O.
VIBRATING BELL
B
TO LINE SIDE OF LP
IN RSC
F
FA
1500 mm 230V, 2P
ENCLOSED ACB
RATING: 20AT, 50AF,
IN 15mmO C
2
GROUNDING ROD COPPERWELD
16MMO x 240MM LENGTH
1-8.0mm BARE COPPER WIRE
KWHR METER
FIN. GRADE LINE
GROUND FLOOR LINE
ELECTRICAL
RISER DIAGRAM
METERING CONDUIT
1800 mm
NOT TO SCALE
FIRE ALARM
EXHAUST FAN 1x180w5 1480 230 2 20 50 3.35mm² THW IN 15mmØ C
10 S P A R E 1500 230 2 20 50
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
E-13MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
SD
SINK COUNTER
UP
RAMP
UP
A
C
B
1
S
S
2
k
ii
i
j
j
EF
Sklm
URINAL
SINK COUNTER
UD
STO.
UP
UP
RAMP
S
S
S
10 11
2
p
LP
7
q
q
rr
s s
EF
2 2
2 2
F
S S
2
l
a
a
b
b
ab F
Snop
GROUND FLOOR LIGHTING LAYOUTSCALE : 1 : 100 METERS
SECOND FLOOR LIGHTING LAYOUTSCALE : 1 : 100 METERS
LIGHTING LAYOUT
2 3 4 5 6 7 8 9
98765432
UP
A
1
C
B
DN
UP
DN
LP
6
kjihg
Sef SfScd SfSfSab
22
LP
7
FFF
2 2 2 2 2 2
2 2 2 2 2 22
Sghi
Sjk
2
S
2
S
LP
6
LP
5
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
E-23MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
GROUND FLOOR POWER LAYOUTSCALE : 1 : 100 METERS
SECOND FLOOR POWER LAYOUTSCALE : 1 : 100 METERS
POWER LAYOUT
DN
UP
DN
B
C
1
A
UP
2 10 11
SD
SINK COUNTER
UP
RAMP
UP
A
C
B
1
URINAL
SINK COUNTER
UD
STO.
UP
UP
RAMP
10 11
BB
BB
TO C.O.
TO F.A.
ENCLOSED AIR CIRCUIT BREAKER RATING
230V 2P 100AT 100AF TO LINE SIDE OF
PANEL
OVERHEAD SERVICE ENTRANCE REFER
TO RISER DIAGRAM
LP
2
LP
1
2 3 4 5 6 7 8 9
3 4 5 6 7 8 9
LP
4
LP
3
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
NQM
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
BERNADETTE N. AQUINO
STRUCTURAL CONSULTANT, PFSED-DepED
E-33MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
OUTLET
ROOF DRAIN LAYOUTSCALE : P-1
2
1 : 100 METERS
9000
4500
7000
2500
4500
9000
1 32
4500 4500
9000
4500
4 5
4500
6 7
4500
8 9 10 114500600 9000
4500
4500 600
LN. OF STRUCTURE
RD
RD
1000
1000
B
C
A
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
ROOF DRAIN LAYOUT , PLUMBING RO-IN LAYOUT
PLUMBING RO-IN LAYOUTSCALE : P-1
1
1 : 100 METERS
DS
CLASSROOM
75mmØ PVCVDS
CB
HB75mmPVCDS
FD
CB 150mmØ CDP
150mmØ CDP
4 5 6
20mm
Ø GI
CWL
150m
mØ C
DP
150mmØ CDP TO MAINDRAINAGE SYSTEM
CB
C
B UP
UP
RAMP
75mmPVCDSFD
75mmPVCVSTR
100mmĐ PVCSP
12mmØ GICWL
50mm
PVCS
P
WC
100m
mØ P
VCSP
50mmØ PVCVRRISER
12mmØ GICWL
50mmØ PVCVTW
STO.
LAV
WC
FD
12m
mØ
GICW
L
A WC
CB
5
0
m
m
P
V
C
V
S
T
R
1
CO
50mm
PVCS
P
CO
12m
mØ
GICW
L
CS
FD CO
75mmØPVCDS
50mm
PVCW
P
SS
150mmØ CDP
32
100mmĐ PVCSP
75mmPVCVSTR
20mm
Đ GICW
L
38mmØ GICWL
38mmØ GICWL TO MAIN
WATER SYSTEM
UP
RAMP
150mmØ CDP TO MAINDRAINAGE SYSTEM
UP
75mmØ PVC PIPE (VSTR)75mmPVCDS
100mm� PVCSP
CO
SEPTIC TANK OUTLET
50mmPVCVSTR RISER
50m
mĐ
PVC
WP
100m
mĐ
PVC
SP
12mmĐ GICWL
12mmØ GICWL CS
CO
FD
12mm
Đ GICW
L
CV
STO.
WC
LAVFD
CO
100m
mĐ
PVC
SP
100CO
75mmĐ PVCDS
UD
100mmĐ PVCSP
CB
WC
CO
5
0
m
m
P
V
C
V
S
T
R
5
0
m
m
P
V
C
V
S
T
R
11
75mmPVCDS
75mmØ PVC PIPE (VSTR)
50mmØ PVCVTW
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
EMEC
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
ELIAS M. EMEL B. CUBA II
ENGINEER III, PFSED-DepED
P-13MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
PLUMBING RO-IN LAYOUTSCALE : P-1
1
1 : 125 METERS
DS
CLASSROOM
75mmØ PVCVDS
CB
HB
75mmPVCDS
FD
CB
150mmØ CDP
150mmØ CDP
4
5
6
DS
CLASSROOM
75mmØ PVCVDS
CB
HB
75mmPVCDS
FD
CB
150mmØ CDP
150mmØ CDP
3
4
20mmØ GICWL
150mmØ CDP
150mmØ CDP TO MAIN
DRAINAGE SYSTEM
CB
C
B
UP
UPRA
MP
7
5
m
m
P
V
C
D
S
FD
75mmPVCVSTR
100mmØ PVCSP
12mmØ
GICWL
50mmPVCSP
WC
100mmØ PVCSP
50mmØ PVCVR
RISER
12mmØ
GICWL
50mmØ
PVCVTW
STO.
LAV
WC
FD12mmØ
GICWL
A
WCCB 5
0mmPVCVSTR
1
CO
50mmPVCSP
CO 12mmØ GICWL
CSFD
75mmØ
PVCDS
50mmPVCWP SS
150mmØ CDP
3
2
100mmØ PVCSP
75mmPVCVSTR
20mmØ GICWL
DS
CLASSROOM
75mmØ PVCVDS
CB
HB
75mmPVCDS
FD
CB
150mmØ CDP
150mmØ CDP
9
10
DS
CLASSROOM
75mmØ PVCVDS
CB
HB
75mmPVCDS
FD
CB
150mmØ CDP
150mmØ CDP
7
8
75mmPVCDS
FD
CB
38mmØ GICWL
38mmØ GICWL TO
MAIN WATER SYSTEM
UPRA
MP
150mmØ CDP TO
MAIN DRAINAGE
SYSTEM
UP
75mmØ PVCVDS
CB
75mmØ PVC
PIPE (VSTR)
75mmPVCDS
100mmØ PVCSP
CO
SEPTIC TANK
OUTLET
50mmPVCVSTR
RISER
50mmØ PVCWP
100mmØ PVCSP
12mmØ GICWL
12mmØ GICWL
CS
COFD
12mmØ GICWL
CVSTO.
WCLAV
FD CO
100mmØ PVCSP
100CO
75mmØ
PVCDS UD
100mmØ PVCSP
CB
WC
CO
50mmPVC
VSTR
50mmPVC
VSTR
50mmØ PVCVTW
11
75mmPVCDS
75mmØ PVC
PIPE (VSTR)
TWO STOREY
EIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
EMEC
MMC
LGP
LUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
ELIAS M. EMEL B. CUBA II
ENGINEER III, PFSED-DepED
P-23
MAXIMO M. CALBANG
PDO III, PFSED-DepED
ISOMETRIC VIEW
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
EMEC
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
ELIAS M. EMEL B. CUBA II
ENGINEER III, PFSED-DepED
P-23MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :
CB CATCH BASIN
CDP CONCRETE DRAIN PIPE
CO CLEAN OUT
CV CHECK VALVE
HB HOSE BIBB
FD FLOOR DRAIN
GICWL GALVANIZED IRON COLD WATER LINE (SCH. 40)
GV GATE VALVE
MH MANHOLE
PVCDP POLYVINYL CHLORIDE DRAIN PIPE
LAV LAVATORY
WC WATER CLOSET
UD URINAL DRAIN
RD ROOF DRAIN
GICWR GALVANIZED IRON COLD WATER RISER (SCH. 40)
PVCDS POLYVINYL CHLORIDE DOWNSPOUT
PVCSP POLYVINYL CHLORIDE SOIL PIPE
PVCVAC POLYVINYL CHLORIDE VENT. ACROSS CEILING
PVCVP POLYVINYL CHLORIDE VENT. PIPE
PVCVS POLYVINYL CHLORIDE VENT STACK
PVCVTR/W POLYVINYL CHLORIDE VENT TROUGH ROOF/WALL
PVCWP POLYVINYL CHLORIDE WASTE PIPE
PVCWS POLYVINYL CHLORIDE WASTE STACK
PIPE CLEAN-OUTSCLEAN-OUTS ARE REQUIRED UNDER THE F0LLOWING CONDITIONS:a) EVERY CHANGE OF HORIZONTAL DIRECTION EXCEEDING TWENTY TWOAND ONE-HALF DEGREES (22 1/2°).b) ONE AND ONE-HALF METERS (1.50m.) INSIDE THE PROPERTY LINES BEFORE THE HOUSE DRAINAGE CONNECTION.c) EVERY FIFTEEN METERS (15.00m) IN HORIZONTAL RUN OF PIPES.d) AT THE END OF ANY HORIZONTAL PIPE LINES.
THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE WATERPROOFED.
NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE BUILDING.
1.
2.
3.
1.4.
5.
7.
8.
6.
2500
250
VAR.
749
375
4750
6250
7000
375
SCALE :
1
P-3
SEPTIC TANK DETAIL1:40 Mts.
2503
13624
MH
375
6250
7000
375
1500
MH
375
9999375
1% SLOPE
NGL
MH
WATER
LEVEL
LEACHING
GRAVEL BED
CHAMBER
AIR SPACE
INLET
DIGESTIVE CHAMBER
MH
125
375
SCALE :
5
P-3
CATCH BASIN DETAIL SECTION1:20 MTS.
WATER LEVEL
i. LIVE LOAD_________________ 1000Pa
4. ASSUMED ALLOWABLE BEARING CAPACITY Y = 100KPa
FOR BARS SMALLER THAN 16mmØ
fm' =6.90 MPa, fm = 2.41 MPa 2. CONCRETE MASONRY UNITS (LOAD BEARING CHB)
a. FOR FOOTING, BEAMS AND SLABS
WATER TABLE IS 1500 BELOW GROUND LEVEL.
fy = 230 MPa
1. CONCRETEii ALLOWABLE STRESSES
3. REINFORCING STEEL BARS
fc'' = 20 MPa
NOTE:
DESIGNCRITERIA
PLUMBING NOTES:
LEGEND:
375375 2500
1500
1750 375375
375
1500 500500 3750 3750375 3751750
125
125
2250
2250
375 10000
AIR SPACE
OUTLET
P-3
2
NGL
SCALE :
2
P-3
SECTION DETAIL1:40 Mts. SCALE :
3
P-3
SECTION DETAIL1:40 Mts.
100
CDP
OUTLET
CDP
INLET
INLET OUTLET
100
100
700
75
150400150
700
400
150
150
150400150
700
SCALE :
5a
P-3
DETAIL PLAN1:20 M
2% SLOPE50
502% SLOPE
600 min.
(VARIABLE)
50
600
50
50 50
100
100 250250
3-10mmØ (E.W.)
10mmØ BAR HANDLE
SCALE :
4
P-3
MANHOLE COVER DET.1:10 Mts.
P-3
3
SCALE :
5b
P-3
DETAIL SECTION1:20 M
CS COUNTER SINK
PVCDS POLYVINYL CHLORIDE DOWNSPOUT
SEPTIC TANK, CATCH BASIN & COVER DETAIL, LEGEND,NOTES & DESIGN CRITERIA
13625
3999
749
375
249
5375
S-1a S-1a
125 (TYP.)
150mm THK. CHB
GRADES OF HORIZONTAL PIPINGS RUN ALL HORIZONTAL PIPINGS IN PERPECT ALIGNMENT AND AT A FORM GRADENOT LESS THAN TWO PERCENT (2%)
CHANGE IN DIRECTION ALL CHANGE IN DIRECTION SHALL BE MADE BY APPROPRIATE USE OF FORTY-FIVE DEGREES (45°)WYES, LONG SWEEP QUARTER BEND, SIXTH-EIIGHT OR SIXTEENTH BEND. WHEN THE CHANGE OF FLOW IS FROMHORIZONTAL TO VERTICAL A SINGLE 1/8 BEND COMBINATION MAYBE USED ON VERTICAL STACKS AND SHORT QUARTERBENDS MAYBE USED ON WASTE LINE, TEE AND CROSSES MAYBE USED IN BENT PIPES.
PROHIBITED FITTINGS NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL AND WASTE LINES, THEDRILLINGS AND TAPPING OF HOUSE DRAIN, WASTE OR VENT PIPES AND USED OF SADDLE HUB AND BEND AREPROHIBITED.
NOT LESS THAN 0.30 METER OF AIR SPACE MUST BE LEFT BETWEEN THE TOP OF THE SEWAGE AND THE UNDER PART OFVAULT ROOF SLAB.
ALL PLUMBING WORKS SHALL BE UNDER THE SUPRVISION OF A LICENSED MASTER PLUMBER AND A LICENCED PLUMBINGCONTRACTOR.
100mm THK.+FIN. SLAB w/10mmØ REBARS@200mm OC BENT UP 2 OUT OF 3 AT L/4 FROMFACE SUPPORT BOTHWAYS
150x300mm RC BEAM w/2-16mmØ TOP ANDBOT. REBARS & 10mmØ STIRRUPS 1@50,3@100, REST @300mm OC
PLASTERED w/WATERPROOFINGCOMPOUND OR APPLY ONE FACEBITUMEN TAR
WALL REINFORCEMENT 10mmØ VERT. &HOR. BAR @200mm OC BW
100mm THK. SLAB w/ 10mmØ REBARS@300mm BOTHWAYS
100mm THK. + FIN. SLAB w/100mmØBENT UP 2 OUT OF 3 @L/4 FROM FACESUPPORT BW
AIR SPACE
PLASTERED w/WATERPROOFINGCOMPOUND OR APPLY ONE FACEBITUMEN TAR
WALL REINFORCEMENT 10mmØ VERT. &HOR. BAR @200mm OC BW
100mm THK. SLAB w/ 10mmØ REBARS@300mm BOTHWAYS
INLETS
S-1a 100mm THK. + FIN. SLAB w/ 100mmØREBARS @300mm OC BENT UP 2 OUT OF 3 @L/4FROM FACE SUPPORT BOTHWAYS
2-100mmØ EXTRA BARS TOP/BOT. ONTWO PARALLEL SIDE
S2 100mm THK. + FIN. SLAB w/10mmØ REBARS @300mm OC BENT UP2/3 OUT @L/4 FACE SUPPORT ANDSHORT SPAN 10mmØ TEMP. BARS@300mm EW
INLET
500
DRAINAGE PIPE
150mm THK. CHB w/100mmØ REBARSHOR. @2-LAYER VERT. @600mm OC.
TWO STOREYEIGHT (8) CLASSROOM
G.I. ROOF SCHOOL BUILDING
EMEC
MMC
LGPLUIS G. PURISIMA
HEAD, PLANNING AND DESIGN UNIT
PFSED-DepED
ELIAS M. EMEL B. CUBA II
ENGINEER III, PFSED-DepED
P-33MAXIMO M. CALBANG
PDO III, PFSED-DepED CHIEF, PFSED-OPS
OLIVER R. HERNANDEZ
DepED
UNDERSECRETARY
RAMON C. BACANI
DepED
DEPARTMENT OF EDUCATION
REPUBLIC OF THE PHILIPPINES
MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION
RECOMMENDING APPROVAL : SHEET NO:
REP. ACT 545
OWNER :
SHEET CONTENTS :
DEPARTMENT OF EDUCATION
DepED
ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.
THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF TASK FORCE ENGINEERING, ASSESSMENT AND
MONITORING AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,
PROJECT NO:
DATE :
PROJECT TITLE :
LOCATION :
DESIGNED BY:
CHECKED BY:
ENCODED BY:
NOTE:
DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :
EDpeD
NOISI
VID
GNIRE
ENIGN
ESL
OOHCSDNA
SEITI
LICAF
LACI
SYHP
APPROVED BY :