REPUBLIC OF THE PHILIPPINES TABLE -...

21
75mmØPVCDS DEPARTMENT OF EDUCATION REPUBLIC OF THE PHILIPPINES MERALCO AVENUE, PASIG CITY PHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION E D p e D N O I S I V I D G N I R E E N I G N E S L O O H C S D N A S E I T I L I C A F L A C I S Y H P TABLE OF ENGINEER/BUILDING OFFICIAL OFFICE OF THE CITY/MUNICIPAL REPUBLIC OF THE PHILIPPINES CONTENTS DISTRICT/CITY/MUNICIPALITY

Transcript of REPUBLIC OF THE PHILIPPINES TABLE -...

  • PERSPECTIVE VIEW, TABLE OF CONTENTS

    GROUND, TYP. 2nd & 3rd FLOOR PLAN, FINISHES

    FRONT, REAR ELEVATIONS

    TOILETS, STAIRS & RAMP DETAIL

    RIGHT, LEFT ELEV., LONGITUDINAL & CROSS SECTION

    TOILET SECTION DETAILS, FACADE PEDIMENTS

    PERSPECTIVE VIEW & TABLE OF CONTENTSA-1

    A-2

    A-3

    A-6

    A-5

    A-4

    A-7

    S-1

    S-2

    S-3

    S-4

    1A-1 SCALE : N T S

    P-1

    P-2

    THIRD FLOOR REFLECTED CEILING & ROOF PLAN

    STAIR, HANDRAIL & MISC. DETAILSA-8

    E-1 GENERAL NOTES, SINGLE LINE DIAGRAM,

    LOAD SCHEDULE, LEGEND & RISER

    DIAGRAM

    E-2 GROUND & TYP. 2nd & 3rd FLOOR POWER

    LAYOUT

    E-3 GROUND & TYP. 2nd & 3rd FLOOR LIGHTING

    LAYOUT

    P-5 SEPTIC TANK, CATCH BASIN & COVER

    DETAILS, NOTES, LEGEND, DESIGN CRITERIA

    FOUNDATION PLAN, DET. OF FOOTING, TIE

    BEAM, STAIR ON GRADE & RAMP, ELEV. OF

    COL. SCH. FOOTING & COLUMN

    2nd & 3RD FLOOR FRAMING PLAN, TYP. DET.

    OF BEAM & SLAB, SCH. OF BEAMS & SLABS

    STAIR PLAN & SECTION DETAIL, MISC. DETAILS

    ROOF FRAMING PLAN, TRUSS DIAGRAM DETAILS

    OF STEEL CONNECTION

    DOOR & WINDOW SCHEDULE, DETAIL OF STEEL

    CASEMENT

    A-9

    DRAINAGE AND SANITARY SYSTEM LAYOUT

    DARINAGE AND SANITARY SYSTEM

    ISOMETRIC VIEW

    WATER SYSTEM ISOMETRIC DIAGRAM

    WATER SYSTEM LAYOUTP-3

    P-4

    CHIEF, PFSED-OPS

    OLIVER R. HERNANDEZ

    DepED

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED UNDERSECRETARY

    RAMON C. BACANI

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    ISOMETRIC VIEWDEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

    TABLEOF ENGINEER/BUILDING OFFICIAL

    OFFICE OF THE CITY/MUNICIPAL

    REPUBLIC OF THE PHILIPPINES

    CONTENTS

    DISTRICT/CITY/MUNICIPALITY

  • SCALE :

    1

    A-2 1 : 100 METERS

    2A-2 SCALE : 1 : 100 METERS

    C O R R I D O R

    UP UP

    C O R R I D O R

    GROUND, 2nd & 3rd TYPICAL FLOOR PLAN, FINISHES

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    4500 4500

    CLASSROOM

    1

    4500 4500

    CLASSROOM

    2

    4500 4500

    CLASSROOM

    4

    4500 4500

    CLASSROOM

    5

    C O R R I D O R

    WF2WF2 WF2

    WF2WF2 WF2

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    25mm

    DEP

    WF1

    25mm

    DEP

    FL1

    BLACKBOARD BASE

    WF1

    FL1

    W

    1

    W

    1

    W

    2

    W

    2

    D1

    D1

    CONCRETE SUNBREAKER

    LINE OF SUNBREAKER

    A-6

    3

    LINE OF ROOF FOR

    THIRD FLOOR

    A-6

    2

    A-6

    4

    A-6

    1

    A-7

    1

    A-8

    10

    9000

    LANDING LANDING

    LANDINGLANDING

    163

    STO STO

    7000

    9500

    1500

    2500

    DN

    1090

    1400

    600

    200x200mm

    VITRIFIED FLOOR

    TILES (UNGLAZED)

    4500

    960 960 1200

    SHE

    SINK COUNTER D-2

    D-2

    D-4

    W

    3

    D-4 D-4

    STO

    W

    4

    955

    7000

    9500

    1500

    DN

    2500

    4500

    1000 10002075

    SINK COUNTER

    W

    3

    HED-4

    D-2

    2000

    WCURINAL

    D-4

    600

    200x200mm

    VITRIFIED UNGLAZED

    FLOOR TILES

    WC

    1400

    7000

    3850

    RAMP

    1200

    3600 1700

    2500

    UP

    D-3a

    1500UP

    2000

    3150

    4500

    W

    4

    D-3

    NCR

    W

    3

    HE

    SINK COUNTER

    D-4

    URINAL

    LAVWC WC

    D-2

    W

    3

    SINK COUNTER

    1750

    1700

    SD

    1400

    200x200mm VITRIFIED

    FLOOR TILES

    (UNGLAZED)

    3625

    3600

    UP

    RAMP

    1200

    1500

    D-3a

    UP

    850 850

    WF3

    W

    4

    D-3SHE

    D-4D-4

    2000

    1200

    1525

    A-4

    3

    A-4

    4

    A-4

    3

    A-4

    4

    650

    4500 4500

    4500

    1700 850

    54000

    CLASSROOM3

    WITH GROOVES

    SCHEDULE OF FINISHES

    - PLAIN CEMENT FLOOR FINISH

    - PLAIN CEMENT FLOOR ROUGH

    ( UNGLAZED )

    - 200X200 VITRIFIED FLR TILES

    WF2

    WF1

    WF3

    WALLS :

    FL3

    FLOORS :

    FL1

    FL2

    - 100 MM THK. CHB W/ PLAIN CEMENT PLASTER FIN (PAINT) 50mm G.I. PIPE FOR HANDRAIL

    - 200X200 VITRIFIED WALL TILES

    (GLAZED)

    - 150 MM THK. CHB W/ PLAIN CEMENT PLASTER FIN (PAINT)

    FL1

    4500 4500

    CLASSROOM

    6

    WF1

    FL1

    4500 4500

    CLASSROOM

    7

    WF1

    FL1

    4500 4500

    CLASSROOM

    8

    WF1

    FL1

    4500 4500

    CLASSROOM

    9

    WF1

    FL1

    4500 4500

    CLASSROOM

    10

    WF1

    54000

    1750

    SS

    HCR

    425

    425425

    PIPE CHASE

    PIPE CHASE

    PIPE CHASE

    PIPE CHASE

    425 650773

    A-7

    1

    3850

    2500

    3150

    9500

    CHIEF, PFSED-OPS

    OLIVER R. HERNANDEZ

    DepED

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED UNDERSECRETARY

    RAMON C. BACANI

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    ISOMETRIC VIEWDEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • 9925

    THIRD FLOOR LEVEL

    NAT. GRD. LN.

    GROUND FLOOR LEVEL

    3200

    325

    3200

    1 : 100 METERS

    2

    A-3 SCALE :

    APEX LINE OF TRUSS

    TOP OF ROOF BEAM

    2500

    1 : 100 METERS

    SCALE : A-3

    1

    D-1

    W-2

    D-1

    W-2

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    GM

    A

    CA RE

    S

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    GM

    A

    CA RE

    S

    SECOND FLOOR LEVEL

    3200

    FRONT, REAR ELEVATIONS

    CONCRETE SUN BREAKER

    (SEE DETAIL)

    PLAIN CEMENT PLASTER

    PAINT FINISH

    GA#26 PL. G.I. GUTTER ON12x300mm FIBER CEMENT

    FASCIA BD. (PAINT FINISH)

    GA#26 CORR. G.I. ROOFINGSHEET (PAINT FIN.)

    GA. #26 CORR. G.I.ROOFING SHEET (PAINTFINISH)

    GA. #26 PLAIN G.I.GUTTER ON

    12x300mm FIBER

    CEMENT FASCIA BD.

    (PAINT FINISH)

    100 MM THK. CHB

    RAILING W/50mm G.I. PIPE RAILING

    32mm G.I. PIPE

    HANDRAIL WITH 32mm

    VERT. SUPPORT @ 600mm

    O.C. (PAINT FINISH)

    D-2

    D-2

    D-2

    9925

    SECOND FLOOR LEVEL

    NAT. GRD. LN.

    GROUND FLOOR LEVEL

    3200

    325

    3200

    APEX LINE OF TRUSS

    TOP OF ROOF BEAM

    2500

    THIRD FLOOR LEVEL

    3200

    D-2

    D-2

    D-2

    W

    3

    W

    3

    W

    4

    W

    4W

    3

    W

    4W

    3

    W

    4W

    3

    2985

    W

    3

    815

    D-3A D-3A

    - 100 MM THK. CHB W/ PLAIN CEMENT PLASTER FIN (PAINT) 50mm G.I. PIPE FOR HANDRAIL

    - 200X200 VITRIFIED WALL TILES

    (GLAZED)

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    FF F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    W-2

    D-1

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • 12425

    3200

    2500

    3200

    NAT. GRD. LN.

    GROUND FLOOR LEVEL

    325

    3200

    SECOND FLOOR LEVEL

    4A-4 SCALE : 1 : 100 METERS

    THIRD FLOOR LEVEL

    NAT. GRD. LN.

    GROUND FLOOR LEVEL

    9925

    3200

    325

    3200

    CLASSROOM

    A-4

    3

    1 CORRIDOR

    1 : 100 METERSSCALE :

    CLASSROOM

    W-1

    W-1

    10 CORRIDOR

    D-1

    APEX OF TRUSS

    600

    THIRD FLOOR LEVEL

    TOP OF TRUSS

    TOP OF ROOF BEAM

    7000

    95001000

    2500

    SEE TRUSS DETAIL

    1A-4 SCALE : 1 : 100 METERS

    9925

    3200

    3200

    325

    NAT. GRD. LN.

    GROUND FLR. LVL.

    SECOND FLR. LVL.

    TOP OF ROOF BEAM

    APEX LINE OF TRUSS

    1100

    1000

    2A-4 SCALE : 1 : 100 METERS

    1000

    2500

    TOP OF ROOF BEAM

    CLASSROOM

    W-1

    6 CORRIDORSECOND FLOOR LEVEL

    3200

    3200

    THIRD FLR. LVL.

    RIGHT & LEFT SIDE ELEV., LONGITUDINAL & CROSSSECTION

    2 3

    THIRD FLOOR LEVEL

    NAT. GRD. LN.

    GROUND FLOOR LEVEL

    9925

    3200

    325

    3200

    TOP OF TRUSS

    TOP OF ROOF BEAM

    SECOND FLOOR LEVEL

    3200

    600

    SEE STRUCTURAL DETAIL

    W

    3

    W

    4

    200x200mm

    VITRIFIED WALL

    TILES (GLAZED)

    CONCRETE

    SUNBREAKER (SEEDETAIL)

    32mm GI PIPE HANDRAIL

    w/32mm VERT. SUPPORT@600mm O.C. (PAINT FIN.)

    GA#26 CORR. G.I.ROOFING SHEET

    (PAINT FIN.)

    GA#26 PLAIN G.I. GUTTERON 12x300mm FIBER

    CEMENT FASCIA BOARD

    (PAINT FIN.)

    PLAIN CEMENT PLASTER

    WALL PAINT FIN.

    CONCRETE

    SUNBREAKER (SEEDETAIL)

    GA#26 CORR. G.I.ROOFING SHEET

    (PAINT FIN.)

    GA#26 G.I. GUTTERON 12x300mm

    FIBER CEMENT

    FASCIA BOARD

    (PAINT FIN.)

    PLAIN CEMENT PLASTER

    WALL PAINT FIN.

    38mm G.I. PIPE

    HANDRAIL

    w/32mm VERT.SUPPORT @600mm

    O.C. (PAINT FIN.)

    GA#26 CORR. G.I.ROOFING SHEET

    (PAINT FIN.)

    CONCRETE

    SUNBREAKER

    (SEE DETAIL)

    FEMALE

    TOILET

    FEMALE

    TOILET

    FEMALE

    TOILET

    STORAGE

    STORAGE

    W

    3W

    4

    W

    3W

    4

    MALE

    TOILET

    MALE

    TOILET

    MALE

    TOILET

    W

    4

    200x200mm

    VITRIFIED WALL

    TILES (GLAZED)

    W

    3

    W

    3

    EXPOSED CEILING UNDER

    SLAB PAINT FIN.

    EXPOSED CEILING UNDER

    SLAB PAINT FIN.

    WC WCCS

    LAV

    3mm THK. FASCIAL

    MIRROR ON AL.

    FRAME

    50mm G.I. PIPE

    RAILING PAINT FIN.

    1100

    D-1

    D-1

    840

    900

    200

    900

    900

    W

    3

    6mm THK. MARINE PLYWOOD

    CEILING FOR ALL TOILET ON

    50x50mm CEILING JOIST

    @600mm ON CENTER

    BOTHWAYS w/10mm BARHANGER @1200mm OC.

    BOTHWAYS EMBEDDED ON

    CONC. SLAB

    300

    3200

    3200

    3225

    TOP OF ROOF BEAM

    3rd FLOOR TOILET LEVEL

    2nd FLOOR TOILET LEVEL

    GROUND FLOOR TOILET

    LEVEL

    1100 200200

    CLASSROOM

    CLASSROOM

    CLASSROOM

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1 CLASSROOM

    CLASSROOM

    CLASSROOM

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1 CLASSROOM

    CLASSROOM

    CLASSROOM

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1 CLASSROOM

    CLASSROOM

    CLASSROOM

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1 CLASSROOM

    CLASSROOM

    CLASSROOM

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    F F F F

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    W

    1

    11

    6

    1

    12

    7

    13

    8

    14

    9

    4

    15

    10

    5

    2500

    815

    2500

    10

    A-8

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • SCALE : A-5

    2

    1 : 100 METERS

    1A-5 SCALE : 1 : 100 METERS

    1000

    1000

    2500

    A-8

    600

    600

    THIRD REFLECTED CEILING, ROOF PLAN

    9000

    4500

    7000

    2500

    4500

    9000

    4500

    9000

    4500

    4500

    4500

    4500600 4500 600

    LN. OF STRUCTURE

    RD RD

    1000

    1000

    4500

    9000

    4500

    GA#26 CORR. G.I. SHEETROOFING (PAINT FIN.)

    GA#26 PLAIN G.I. RIDGEROLL (PAINT FIN.)

    GA#26 PLAIN G.I. FLASHING(PAINT FIN.)

    9000

    4500

    4500

    9000

    4500

    4500

    SLOPE

    SLOPE

    SLOPE

    SLOPE

    CEILING VENTILATION (SEEDETAIL)

    GA#26 PLAIN GI GUTTER ON12x300mm FIBER CEMENT FASCIA

    BOARD (PAINT FIN.)

    6mm THK. ORD. PLYWOOD CEILING ON

    50x50mm CEILING JOIST @600mm OC

    BOTH WAYS (PAINT FIN.)

    LIGHTING FIXTURES

    6mm THK. MARINE PLYWOOD

    CEILING ON 50x50mm CEILING

    JOIST @600mm OC BOTH WAYS

    (PAINT FIN.)

    A-7

    7

    CONCRETE PARAPET

    CONCRETE PARAPET

    GA#26 G.I. GUTTER ON12x300mm FIBER CEMENT

    FASCIA BOARD (PAINT FIN.)

    GA#26 G.I. GUTTER ON12x300mm FIBER CEMENT

    FASCIA BOARD (PAINT FIN.)

    45004500

    9000

    4500

    4500

    9000

    4500

    4500

    9000

    4500

    4500

    RD RD RD RD RD RD RD RD RD RD RD

    200 RD RD RD RD RD RD RDRD RD RD RD RD

    MANHOLE MANHOLE

    7000

    4500

    9000

    4500

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • 5b DETAIL SECTION

    A-6 SCALE 1:10 M

    700

    900

    100

    200

    SPOT DETAILSCALEA-6 1:5 M

    100X100 CONCRETE

    SKIRTING

    100

    150

    100

    5b1

    DET. ELEVATION OF RAMP

    A-6

    5

    SCALE 1:50 M

    200

    700

    900

    200

    700

    900

    1200

    300

    32mm G.I. PIPE HANDRAIL

    WITH 32mm VERT. SUPPORT @

    600mm O.C. (PAINT FINISH)

    NONSKID PLAIN CEMENT FLOOR

    FINISH W/ GROOVE LINES

    TOILETS, STAIR & RAMP PLAN ANDRAMP DETAIL

    32 mm G.I PIPE

    VERTICAL SUPPORT @

    600mm ON CENTER

    PROVIDE 12mm

    STEEL DOWELS (PAINTFIN.)

    32mm G.I. PIPE

    HANDRAIL WITH 32mm

    VERT. SUPPORT @600mm

    O.C. (PAINT FINISH)

    32 mm G.I PIPE

    VERTICAL SUPPORT

    @600mm ON CENTER

    PROVIDE 12mm

    STEEL DOWELS (PAINTFIN.)

    NONSKID PLAIN CEMENT

    FLOOR FINISH W/GROOVE LINES

    W

    3

    4500

    SINK COUNTER

    1750

    1700

    600

    9500

    3850

    2500

    SD

    3150

    1400

    200x200mm VITRIFIED

    FLOOR TILES

    (UNGLAZED)

    3600

    UP

    RAMP

    1200

    1500

    D-3a

    UP

    WF3

    W

    4

    D-3SHE

    D-4D-4

    2000

    5000

    7000

    3850

    RAMP

    1200

    3600 1700

    2500

    UP

    D-3a

    1500UP

    2000

    3150

    10251700

    CLEAR

    888

    4500

    W

    4

    D-3

    NCR

    W

    3

    HE

    SINK COUNTER

    D-4

    7000

    9500

    1500

    2500

    DN

    1090

    1400

    600

    200x200mm

    VITRIFIED FLOOR

    TILES (UNGLAZED)

    4500

    960955 960 1200

    SHE

    SINK COUNTER

    D-2

    D-2

    D-4

    W

    3

    D-4 D-4

    STO

    W

    4

    7000

    9500

    1500

    DN

    2500

    4500

    1000 13002100

    SINK COUNTER

    W

    3

    HED-4

    D-2

    1500

    WCURINAL

    D-4

    600

    200x200mm

    VITRIFIED UNGLAZED

    FLOOR TILES

    WC

    1400

    1

    2

    3

    4 16

    5 15

    6 14

    7 13

    8 12

    9 11

    10

    A-8

    5

    A-8

    12

    D-2

    WC WCWCWC WC

    LAVWC

    38mm STAINLESS

    STEEL GRAB BAR

    19

    18

    17

    16

    5 15

    6 14

    7 13

    8 12

    9 11

    10

    1

    2

    3

    416

    515

    614

    713

    812

    911

    10

    19

    18

    17

    416

    515

    614

    713

    812

    911

    10

    WC

    LAV URINAL WC

    38mm STAINLESS

    STEEL GRAB BAR

    A-8

    9

    9-STEPS@300mm = 2700

    1337

    1360 1359

    8-STEPS@300mm = 2400

    1337

    200x200mm

    VITRIFIED UNGLAZED

    FLOOR TILES

    STO.

    STO.

    D-2

    3600 1700

    A-6

    5a

    SPOT DETAIL5a

    A-6 SCALE 1:50 M

    NON-SKID PLAIN

    CEMENT FLOOR

    CEMEMNT FINISH

    100100

    6mm

    TYPICAL

    6mm6mm

    A-6

    5b

    A-6

    5b1

    4

    A-6 SCALE : 1:50

    M

    3

    A-6 SCALE : 1:50

    M

    2

    A-6 SCALE : 1:50

    M

    1

    A-6 SCALE : 1:50

    M

    1075 850 850 1725

    2000

    3000

    1574A-8

    1

    A-8

    1

    425

    425

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    150 mm CDP sloped @ 2%

    C O R R I D O R

    CB

    UP

    CB

    150 mm CDP sloped @ 2%

    100mmCO

    CO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    150 mm

    C

    DP

    sloped @ 2%

    150 mm CDP sloped @ 2%

    RAMP

    UP

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB

    FD

    CO

    100mm PVCWP

    HE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    LAV

    FDWC

    CO

    NCR

    CSCO

    URWC

    FD

    CO

    RISER

    50mm PVCBV

    50mm PVCBV

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    CB

    CBCBCBCBCBCB

    CO

    FDFD

    DS

    DS

    100mm PVCWS

    100mm PVCSS

    CS CSCS CS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    CO

    FDFD

    DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    150 mm CDP sloped @ 2%

    100mm PVCVS

    100mm PVCVS

    LINESEPTIC TANK

    CB CB CB CB

    CB CB CB CB CB

    100mm PVCSP

    150 mm CDP sloped @ 2%

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    2000 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CBCB

    UP

    RAMP

    CB

    100mm PVCHD

    150 mm CDP sloped @ 2%

    FD

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    SD

    75mm PVCHD COCO

    CB

    SLFD

    WCFD

    WCFD

    CO

    CO

    RISER

    10

    0m

    m

    PV

    CH

    D

    100mm PVCSP

    FD WC

    CO

    CS CS

    LAV

    50mm PVCVP

    50mm PVCVP

    150 mm CDP sloped @ 2%

    CB

    1

    P-1 SCALE :

    CB

    UP

    150 mm CDP sloped @ 2% 150 mm CDP sloped @ 2%

    100mmCO

    C O R R I D O R

    150 mm CDP sloped @ 2%

    CB

    UP

    1 : 100 METERS

    CB

    150 mm CDP sloped @ 2%

    CO

    100mmCO

    150 mm CDP sloped @ 2%

    100mm PVCSP

    100mm PVCSPTO SEWER

    100mmCO

    100mm PVCVS

    100mm PVCVS

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCHD75

    mm

    P

    VC

    HD

    75mm PVCHD

    FDWC FD

    CSCSCS50mm PVCVP

    50mm PVCVP

    100mm PVCVS

    100mm PVCVS

    CB CB

    CB

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    150 mm CDP sloped @ 2%

    UP

    RAMP

    2000

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    TO MAIN DRAINSYSTEM

    CBCB

    HE

    100mm PVCHD

    CO

    FD

    100mm PVCSP

    150 mm CDP sloped @ 2%

    NCR

    CO

    WC FD

    10

    0m

    m

    PV

    CH

    D

    150

    mm

    C

    DP

    slo

    ped

    @ 2

    %

    CB

    UP

    CO

    RISER

    CO

    FDWC

    URLAV

    CSCSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    100mm PVCVS

    100mm PVCVS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCHD

    100mm PVCHD

    75

    mm

    P

    VC

    HD

    RISER

    FD

    WC WC

    CSCS

    50mm PVCVP

    50

    mm

    P

    VC

    VP

    50mm PVCVP

    DS DSDS DSDS DS DS

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    100mm PVCWS

    100mm PVCSS

    FDCO

    CO

    WC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    HD

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCWS

    100mm PVCSS

    DN

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    DN

    FDCO

    CO

    WCWC100mm PVCSP

    SHE

    SINK COUNTER

    RISER

    CO

    FD

    CO

    75mm PVCWP75

    mm

    P

    VC

    WP

    75mm PVCWP

    FDFD

    CSCSCS50mm PVCBV

    50mm PVCBV

    100mm PVCVSTR

    CO

    UR

    CO

    CO

    CO

    75mm PVCWP

    100mm PVCSP

    75

    mm

    P

    VC

    WP

    RISER

    FD

    WC WC

    CSCS

    50mm PVCBV

    50

    mm

    P

    VC

    BV

    50mm PVCBV2ND FLR3RD FLR

    CB

    CB

    CB CB CB CB CB CB CB

    CB

    DRANAIGE & SANITARY SYSTEM

    ISOMETRIC VIEW

    P-25

    75mm PVCMVSPVCVTR

    75mm PVCDS

    VSTR

    PIPE CHASEPIPE CHASE PIP[E CHASEPIP[E CHASE

    75mm PVCMVS

    CO

    FDFD

    DS

    CO

    FDFD

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    CO

    75mm PVCDS

    DS

    150 mm

    C

    DP

    sloped @ 2%

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • TOILET SECTION DETAILS

    150

    URINAL

    300

    1625

    1525

    100

    3200

    CLASSROOM LVL.

    TOILET LVL.

    2ND FLR. LVL.

    50

    3200

    4500

    300

    1600

    1650

    3250

    CLASSROOM LVL.

    TOILET LVL.

    2ND FLR. LVL.

    50

    2695

    3200

    4549

    1

    A-7

    DET. SECTION OF FEMALE TOILETSSCALE 1:50 M

    6

    A-7

    MOUNTING FIXTURES OF MALE TOILETSCALE 1:50 M

    FIN. GRD. LN.

    TOILET LVL.

    FIN. GRADE LN.

    TOILET LVL.

    500500

    SD

    200

    600

    3mm THK. FASCIAL

    MIRROR ON AL. FRAMING

    200x200mm VITRIFIED

    WALL TILES (GLAZED)

    CONC. COUNTER

    800

    600

    300

    PLAIN CEM. PLASTER

    PAINT FIN.

    PLAIN CEM. PLASTERED

    PAINT FIN.

    200x200mm GLAZED

    WALL TILES

    COUNTER SINK DET. PLAN

    600

    1900

    200x200mm VITRIFIED

    GLAZED TILES

    5

    A-7

    DETAIL SECTIONSCALE 1:20 M

    200x200mm VITRIFIED

    GLAZED WALL TILES

    600

    70

    100

    100

    15 25

    50 300200

    150

    URINAL

    WC

    38 STAINLESS STEEL

    GRAB BAR

    300

    3RD FLR. LVL.

    3200

    TOP OF BEAM LVL.

    3225

    1625

    30050

    3200

    4500

    900

    FIN. GRD. LN.

    CORRIDOR LVL.

    TOILET LVL.

    325

    3200

    3200

    1600

    1600

    450450

    200200

    2

    A-7

    DET. SECTION OF MALE TOILETSSCALE 1:50 M

    FEMALE

    TOILET

    FEMALE

    TOILET

    FEMALE

    TOILET

    STORAGE

    STORAGE

    W

    3W

    4

    W

    3W

    4

    W

    3W

    4

    MALE

    TOILET

    MALE

    TOILET

    MALE

    TOILET

    W

    3

    WC 780

    3

    A-7

    DETAIL OF COUNTER SINKSCALE 1:20 M

    DETAIL SECTIONSCALE 1:20 M

    DET. SECTIONSCALE 1:20 M

    LAV

    WC

    W

    3

    W

    3

    WC WC WC

    WC WC WC

    1600

    A-8

    8

    1000

    1600

    1800

    100

    200 20060

    PLAIN CEMENT PLASTER

    PAINT FINISH

    200x200mm

    VITRIFIED WALL

    TILES ( GLAZED )

    CORRIDOR LVL.

    W

    3

    W

    3

    6mm THK. MARINE

    PLYWOOD CEILING ON

    50x50mm CEILING JOIST

    @600mm OC BW.

    w/10mm BAR HANGEREMBEDDED ON SLAB

    @1200mm OC. BW.

    150

    TOILET LVL.

    TOILET LVL.

    GROUND FLOOR

    2nd FLOOR

    3rd FLOOR

    TOP OF ROOF BEAM

    13195

    650

    9425

    9000

    1000

    1000

    1000

    802

    654

    392

    1452

    40

    1000

    1000

    1000

    1000

    1000

    1000

    650

    4175

    650

    80

    500

    268

    654

    80

    1525

    650

    150

    650

    350

    150mM THK. CHB

    PLASTER FIN. w/40mmGROOVE @1040mm OC &

    10mm REINF. BAR

    @600mm OC. BW.

    PLASTERED PAINT FIN.

    150mm THK. CHB

    PLASTERED PAINT FIN.

    150mm CHB

    GM

    A

    C AR

    ES

    CONCRETE COLUMN

    3315

    1000

    1000

    1000

    40

    1000

    1000

    1000

    1000

    1000

    1000

    DET. SECTION

    CEM. PLASTERED FIN.

    6" THK CHB PEDIMENT

    1525

    A-7 SCALE

    7a

    783

    200

    1:50 M

    TOP OF ROOF BEAM

    3200

    3200

    3200

    6a

    A-7

    DET. OF FACADE PEDIMENTSCALE 1:50 M

    7

    A-7

    3919

    DET. SECTIONSCALE 1:20 M

    7b

    A-7

    4

    A-7

    7a

    A-7

    7b

    A-7

    6a

    A-7

    (PROVIDE MANHOLE)

    1500

    FFLFFL

    100284

    800

    183100

    1500

    650

    R746

    FFL

    300

    300

    PIPE CHASE

    PIPE CHASE

    PIPE CHASE

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • SCALE :

    10

    A-8 1:20 MTYPICAL DETAIL OF

    BALCONY RAILINGSCALE

    9

    A-8 AS SHOWN

    1:50 M

    SECTION

    700

    SCALE

    C150

    100mm CHB CONC.

    50

    THIRD FLOOR LEVEL

    RAILING W/ PLAIN CEM.PLASTER PAINT FIN.

    SCALE 1:20 M

    SPOT DET.

    EVERY 1200mm

    PAINT FINISH

    W/ 25mm SQ. BAR STEEL BRACKET @

    SCHED. 40 RAILING

    50mm B.I. PIPEC

    200

    A-8

    13

    SCALE : 1 : 10 M

    275

    275

    325 5050

    575 575

    1150

    25x25mm WOOD VENT

    PROVIDE INSECT SCREEN

    NOT

    8

    A-8 SCALETO

    GRAVEL BEDDING

    DAMP PROOFING

    POLYETHYLENE SHEET

    CONCRETE SLAB

    50

    175

    SPOT DETAIL1:5 M

    4

    A-8 SCALE

    50

    5

    A-8

    50

    900

    900

    HANDRAIL DETAIL

    1:5 M

    HANDRAIL @150mm O.C.

    WELDED TO G.I. PIPE

    19mm SQUARE BAR

    175

    100

    7

    A-8 SCALE

    50

    SCALE

    3

    A-8 1:5 M

    300

    2

    A-8

    168

    168

    50

    1:20 M

    DETAIL SECTIONSCALE

    LANDING F.F.L.

    ANCHORED @ R.C. STAIR

    SCHEDULE 40

    50mm G.I. PIPE

    (PAINT FINISH)

    A-8

    3

    W A L L

    6

    A-8

    CRASH RAILINGSCALE 1:20 M

    ANCHORED @ R.C. STAIR150

    SPOT DETAIL1:20 MSCALE

    200

    5050mm G.I. PIPE

    SCHEDULE 40

    (PAINT FINISH)

    19mm SQUARE BAR

    WELDED TO G.I. PIPE

    HANDRAIL @150mm O.C.

    50mm G.I. PIPE

    SCHEDULE 40

    (PAINT FINISH)

    19mm SQUARE BAR

    @150mm O.C. WELDED

    TO G.I. PIPE HANDRAIL

    (PAINT FIN.)

    50mm G.I. PIPE

    SCHEDULE 40

    (PAINT FINISH)

    19mm SQUARE BAR @150mm

    O.C. WELDED TO G.I. PIPE

    HANDRAIL (PAINT FIN.)

    50mm G.I. PIPE

    SCHEDULE 40

    PAINT FINISH

    19 mm SQUARE BAR

    ANCHORED TO THE

    WALL (PAINT FIN.)

    50mm G.I. PIPE

    SCHEDULE 40

    (PAINT FINISH)

    19 mm SQUARE BAR

    ANCHORED TO THE

    WALL (PAINT FIN.)

    38mm STAINLESS

    STL. GRAB BAR

    7000

    200x200mm VITRIFIED

    GLAZED WALL TILES

    1625

    3200

    FINISHED GRADE LINE

    3200

    325

    6

    STORAGE

    3800

    SECTION OF STAIR

    2000

    1

    A-8 SCALE

    FEMALE

    1:50 M

    3

    2

    4

    5

    CORRIDOR1

    10

    W-412

    11

    14

    15

    13

    9

    8

    7

    CORRIDOR

    7000

    A2500

    B C

    50mm G.I. PIPE

    SCHEDULE 40 PAIN. FIN.

    SCHEDULE 40 PAIN. FIN.

    50mm G.I. PIPE

    3200

    3200

    CORRIDOR

    TOP OF ROOF BEAM

    STAIR, HANDRAIL & MISC. DETAILS

    D

    3

    900

    FR. 25x75mm

    WD.FRAME S4S KD

    TANG.

    1125

    16

    17

    18

    19

    6

    3

    2

    4

    5

    1

    10

    12

    11

    14

    15

    13

    9

    8

    7

    16

    17

    18

    19

    1200

    100

    10mm @250mm

    ON CENTER

    675

    100

    12x12mm GROOVE

    BEAM REBARS SEE

    STRUCTURAL DETAIL

    25x25 mm

    WOOD VENT

    PROVIDE INSECT

    SCREEN

    D

    4

    W-4

    W-4

    D

    4

    19mm SQUARE BAR

    RAILING @150mm O.C.

    WELDED TO G.I. PIPE

    50mm G.G. PIPE SCH.

    40 (PAINT FIN.)

    900

    168

    50 300

    950

    A-8

    14

    1 : 10 MSCALE :

    A-8

    14

    A-8

    2

    SPOT DETAIL

    (CRASH RAILING)

    50mm G.I. PIPE

    SCHEDULE 40 PAIN. FIN.

    25x25x2mm THK.

    ANGULAR BAR

    NOSING

    6mm THK. MARINE PLYWOOD

    CEILING ON 50x50mm CEILING.

    JOISTS @600mm O.C. B/W(PAINT FIN.)

    150

    150

    150

    200x200mm VITRIFIED

    GLAZED WALL TILES

    200x200mm VITRIFIED

    GLAZED WALL TILES

    LAV

    WC

    CS

    WC

    CS

    WC

    CS

    25x25x2mm THK.

    ANGULAR BAR

    NOSING

    200x200mm

    VITRIFIED WALL

    TILES ( GLAZED )

    9-RISERS@168mm

    =1512mm

    10-RISERS@168mm

    =1680mm

    9-RISERS@168mm

    =1512mm

    GROUND FLOOR

    TOILET FIN. LINE

    SECOND FLOOR

    TOILET FIN. LINE

    THIRD FLOOR

    TOILET FIN. LINE

    6mm THK. MARINE PLYWOOD

    CEILING ON 50x50mm CEILING

    JOIST @600mm 0N CENTER

    BOTHWAYS W/ 10mm BARHANGER @1200mm OC. BW.

    CONC. BEAM

    QUARTER ROUND

    MOULDING

    6mm THK. ORD.

    PLYWD. CEILING

    (PAINT) ON 50x50mmCLG. JST. @600mm

    OC BW

    SEE TRUSS DET.

    6mm THK. MARINE PLYWD.

    CEILING (PAINT) ON 50x50mmCLG. JST. @600mm OC BW

    A-8

    12

    SCALE 1 : 10 M

    LANDING

    LANDING

    PIPE CHASE

    5

    A-8

    A-4

    5

    SCALE 1 : 20 M

    38mm TEKSCREW

    C-PURLIN (SEE STRUC'LDETAIL)SAG ROD SEE

    STRUCTURAL DETAIL

    GA 26 GI GUTTER

    PAINT FIN.

    GA 26 GI STRAP

    BASKET STRAINER

    75mm PVC

    DOWNSPOUT PAINT

    FINISH

    CEILING VENT (SEEDETAIL)

    6mm THK. MARINE

    PLYWOOD CEILING ON

    50x50mm CEILING

    JOIST @600mm BW

    1000

    6mm THK. ORD.

    PLYWOOD CEILING W/6mm GROOVE ON

    50x50mm CEILING

    JOIST @600mm BW

    (PAINT FIN.)

    ROOF

    BEAM

    TOP CHORD SEE

    STRUCTURAL DETAIL

    5A

    A-4

    GA 26 GI GUTTER

    PAINT FIN.

    GA 26 GI STRAP

    BASKET STRAINER

    75mm PVC

    DOWNSPOUT PAINT

    FINISH

    6mm THK. MARINE

    PLYWOOD CEILING ON

    50x50mm CEILING

    JOIST @600mm BW

    12x300mm FIBER CEMENT

    FASCIA BOARD FIX W/METALSCREW ON STL. FRAME PAINT

    FINISH

    20x20X2mm ANGULAR

    BAR FOR FASCIA BOARD

    FRAME COATED WITH

    PRIMER

    GA 26 CORR. G.I.

    ROOFING SHT. PAINT FIN.

    COPPER RIVET

    38mm TEKSCREW

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • SCALE :

    1

    A-9

    2400

    2100

    D-1

    FFL

    CLASSROOM

    900

    300

    1 : 50 METERS

    TOILET (CUBICLE)

    300

    1500

    1200

    2100

    2100

    D-2 TOILET D-3

    300

    TOILET (DISABLED)

    800

    D-4

    800 900

    600

    TANGUILE PANEL DOOR ON 50X150

    mm YACAL/GUIJO JAMB W/ FIXEDCLEAR GLASS TRANSOM COMPLETE

    WITH HARDWARE AND ACCESSORIES

    HOLLOW CORE FLUSH TYPE SWING

    DOOR ON 50x50mm YACAL GUIJO

    JAMB W/ MARINE PLYWOOD FACINGINSIDE AND ORDINARY OUTSIDE

    COMPLETE W/ HARDWARE ANDACCESSORIES

    HOLLOW CORE FLUSH TYPE SWING

    DOOR ON 50x150mm GUIJO/YACALJAMB w/MARINE PLYWOOD FACINGINSIDE AND ORDINARY OUTSIDE

    COMPLETE W/ HARDWARE ANDACCESSORIES PROVIDE KICK PLATE

    SWING DOOR ON 50X100

    YACAL/GUIJO DOOR JAMBCOMPLETE WITH HARDWARE

    ACCESSORIES

    STAINLESS STL.

    KICKING PLATE

    800

    D-3a

    LOUVER DOOR ON 50X100

    YACAL/GUIJO DOOR JAMBCOMPLETE WITH HARDWARE

    ACCESSORIES

    1 : 20 METERS

    20

    220

    60

    20

    20 2 20

    60 20

    20 2 20

    60 20

    7

    3

    10

    2A-9 SCALE :

    1 : 10 METERS

    4A-9 SCALE :

    35

    32

    SEALANT

    3x35mm Z-BAR

    PUTTY

    CLEAR GLASS

    HINGE

    MULLION

    SPOT WELDFRAME

    MEETING RAIL

    25

    25

    WINDOW JAMB

    WINDOW JAMB

    FULL WELD

    FULL WELD

    10mm BAR

    PVC PIPE

    10mm BAR

    PVC PIPE

    SEALANTZ-BAR FRAME

    CLEAR GLASS

    PUTTY

    I-BAR MULLION

    SPOT WELD

    Z-BAR

    ANGLE PIN

    CHB GROUT

    WINDOW JAMB

    25

    25

    25

    25

    16

    1.6

    35

    1 : 10 METERS

    3A-9 SCALE :

    10mm BAR

    PVC PIPE

    SEALANT

    SEALANTBEAM

    3x25mm Z-BAR

    PUTTY

    CLEAR GLASS

    FRAME

    3x25mm Z-BAR

    TRANSOM

    BAR

    1.6x35mm CONT.

    WEATHERING

    HINGES

    CLEAR GLASS

    GLAZING PIN

    PUTTY

    VENT

    HINGE

    WELD GROUT

    WINDOW SILL

    ANGLE PIN

    CHB

    FRAME

    4EQ. PARTS=

    4000

    1199

    300

    1500

    2400

    1100

    3 EQUAL PARTS = 2000

    600

    900

    1200

    2400

    4EQ. PARTS

    4000

    300

    400

    300

    2400

    2400

    600

    600

    9502 EQUAL PARTS =

    2000

    FF F F F

    W-1 CLASSROOM

    STEEL CASEMENT WINDOW

    WITH FIX GLASS

    W-2 CLASSROOM

    JALOUSIE WINDOWS WITH CLEAR GLASS

    BLADES ON STANDARD ALUMINUM CASING

    ON 50X150mm YACAL/GUIJO JAMBCOMPLETE WITH HARDWARE AND

    ACCESSORIES & STEEL GRILLS ON 300mm

    FROM FLOOR FIN.

    W-3 TOILET

    STEEL AWNING WINDOW

    W-4 TOILET

    STEEL AWNING WINDOW

    DOOR & WINDOW SCHEDULE, DETAILOF STEEL CASEMENT

    SPOT DETAIL

    (CRASH RAILING)

    MANUAL LOCK

    2100

    2000

    1800

    RQD: 30 SETS

    LOC: REAR ELEVATION

    1000 1000 1000 1000

    1000

    OLIVER R. HERNANDEZ

    NQM

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    NATHANIEL Q. MENDOZA

    ARCHITECT III, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED

    RAMON C. BACANI

    CHIEF, PFSED-OPS

    DepED

    UNDERSECRETARY

    DepED

    DEPARTMENT OF EDUCATION

    REPUBLIC OF THE PHILIPPINES

    MERALCO AVENUE, PASIG CITYPHYSICAL FACILITIES AND SCHOOLS ENGINEERING DIVISION

    RECOMMENDING APPROVAL : SHEET NO:

    REP. ACT 545

    OWNER :

    SHEET CONTENTS :

    DEPARTMENT OF EDUCATION

    DepED

    ALL DRAWINGS ARE TO BE RETURNED WHEN NO LONGER IN USE.

    THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF PHYSICAL FACILITIES AND SCHOOLS ENGINEERING

    DIVISION AND AS SUCH MUST NOT BE REPRODUCED OR COPIED IN PART OR IN WHOLE WITHOUT THEIR PERMISSION,

    PROJECT NO:

    DATE :

    PROJECT TITLE :

    LOCATION :

    DESIGNED BY:

    CHECKED BY:

    ENCODED BY:

    NOTE:

    DESIGNER: CHECKED BY : RECOMMENDING APPROVAL :

    EDpeD

    NOI S

    I VIDG

    NIREE

    NIGNE

    SLOOHCSDNASEITILICA F

    L ACI SYHP

    APPROVED BY :

  • TG-2

    4500

    TG-1

    C-3

    F-3

    C-2F-2

    4500450045004500

    BOTHWAYS

    SPACED AT 400

    WITH 10mm

    SLAB ON FILL

    100mm THICK

    TG-1

    TG-2

    TG-1

    TG-2

    TG-1

    TG-2

    C-1

    F-1

    1:100 M.SCALE :

    S-1

    A

    TG-3 TG-3 TG-3 TG-3 TG-3

    TG-3TG-3TG-3TG-3TG-3

    TG-3TG-3TG-3TG-3TG-3

    45004500

    TG-1

    TG-2

    TG-3 TG-3

    TG-3TG-3

    TG-3TG-3

    M

    S-1

    B SCALE NTSSCALE

    C

    (SEE SCHEDULE)

    L

    PLAN

    t

    SECTION

    NGL

    100 mm THICK

    GRAVEL BEDDING

    2ND FLOOR LEVEL

    FOUNDATION LEVEL TO

    2ND FLOOR LEVEL TO

    3RD FLOOR LEVEL

    3RD FLOOR LEVEL TO

    ROOF DECKLEVEL

    LEVEL C-3

    C-1 C-2

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    8-20mm

    TIES : 10 mm

    MAIN BAR:

    8-20mm

    1@50, 8@75, REST @150mm TO CENTER

    350

    350

    350

    350

    WIDTH

    FOOTING DIMENSIONS (mm)

    (W)

    2500

    MARK

    FOOTING

    LENGTH

    (L)

    F-3

    F-2

    F-1

    2800

    1700

    11 - 20mm 1500 300 SQUARE FOOTINGSQUARE FOOTING

    12 - 20mm

    DEPTH

    (D)

    1500

    1500

    350

    300

    (t)

    ThicknessBAR YBAR X

    REINFORCEMENT

    SQUARE FOOTINGSQUARE FOOTING

    SQUARE FOOTINGSQUARE FOOTING

    REMARKS

    12 - 20mm

    11 - 20mm 2500

    2800

    1700 9 - 16mm 9 - 16mm

    SCALE :

    D

    S-11 : 25 M

    REINFORCEMENT OF

    SEE SCHEDULE FOR

    C-3

    G-4/G-6

    LENGTH

    2ND FLOOR LEVEL

    G-5/G-7SEE DEV'TLENGTH

    SEE DEV'T

    NOTE:

    MEMBERS.

    C-4

    2ND FLOOR LEVEL

    G-5/G-7

    S-1

    TG-2

    4500

    TG-3

    TG-3

    TG-3

    TG-1

    TG-2

    TG-1

    TG-2

    TG-1

    TG-2

    TG-1

    TG-2

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    1@50, 10@75, REST @150mm TO CENTER

    14-20mm

    TIES : 10 mm

    MAIN BAR: MAIN BAR:

    TIES : 10 mm

    12-20mm

    150mm TO CENTER

    1@50, 10@75, REST @

    350

    400

    350

    400

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    12-20mm

    350

    350

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    12-20mm

    350

    350

    TG-2

    TG-1

    4500

    TG-3 TG-3

    TG-3TG-3

    TG-3TG-3

    4500

    TG-3

    TG-3

    TG-3

    TG-1

    TG-2

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    TG-2

    TG-1

    4500

    TG-3

    TG-3

    TG-3

    4500

    TG-3

    TG-3

    TG-3

    TG-1

    TG-2

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    C-3

    F-3

    C-2F-2

    C-1

    F-1

    FOUNDATION PLAN, DET. OF FOOTING, TIE BEAM,ELEV. OF COL. SCH. FOOTING & COLUMN

    W

    L

    Y-BARS

    X-BARS

    X-BARS

    Y-BARS

    100

    D

    TIE BEAM

    PC-1 PC-1TG-3

    PC-1PC-1

    TG-3

    3800

    29502950

    A. CONCRETE f'c = 20.685 Mpa (3000psi), minimum compresive strength of concrete a 28 daysunless otherwise specified.

    fy = 275.8 Mpa (40,000 psi), minimum yield strength of reinforcing bars unless otherwise specified.

    SBP = 95.706 Kpa (2000psf) was used in the design for all footings.

    No footing shall rest on fill.

    NSCP 2001, ACI 318-89, AISC ((th Edition)

    B. REBAR

    C. FOUNDATION

    REFERENCES

    WF

    WF

    WFWF

    WF

    WF

    WF WF

    WF

    WF

    WF

    WF

    1:25

    NGL

    100

    300

    500

    1500

    1150

    250

    300

    TOP BARS

    BOTTOM BARS

    10mm STIRRUPS

    1@50, 6@100, REST@200

    RAMPRAMP

    9500

    7000

    2500

    1525

    1400

    5301

    1300

    1525

    5301

    1300

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    8-16mm

    350

    350

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    8-16mm

    MAIN BAR:

    TIES : 10 mm

    150mm TO CENTER

    1@50, 8@75, REST @

    8-16mm

    350

    350

    350

    350

    CHIEF, PFSED-OPS

    OLIVER R. HERNANDEZ

    DepED

    MMC

    LGPLUIS G. PURISIMA

    HEAD, PLANNING AND DESIGN UNIT

    PFSED-DepED

    BERNADETTE N. AQUINO

    STRUCTURAL CONSULTANT, PFSED-DepED

    MAXIMO M. CALBANG

    PDO III, PFSED-DepED UNDERSECRETARY

    RAMON C. BACANI

    DepED

    150 mm CDP sloped @ 2%

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    25mm

    DEP

    SEPTIC TANKLINE

    150 mm CDP sloped @ 2%

    100mm PVCSP

    150 mm CDP sloped @ 2%

    200 mm

    C

    DP

    sloped @ 2%

    TO MAIN DRAINSYSTEM

    CB CB

    RAMP

    UP

    150 mm

    C

    DP

    sloped @ 2%

    FD

    COCO75mm PVCWP

    SD

    10

    0m

    m

    PV

    CW

    P

    RISER

    CO

    CO

    FDWCFD

    WCSS

    CO

    LAV

    WCFD

    150 mm CDP sloped @ 2%

    CB