The Dental X-ray Machine
Reference Reading Chapter 2: pp. 15 - 17
![Page 2: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/2.jpg)
X-rays are produced within the dental x-ray machine
The x-ray machine can be divided into 3 study areas◦ Component Parts◦ The x-ray tube◦ X-ray generating apparatus
X-ray Machine
![Page 3: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/3.jpg)
The Dental x-ray machine consists of 3 visible component parts:◦ The Control Panel
◦ The Extension Arm
◦ The Tubehead
Component Parts
![Page 4: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/4.jpg)
The Component Parts of the Dental X-ray Machine
![Page 5: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/5.jpg)
The Control Panel contains:◦ On-off switch and an indicator light◦ The exposure button and an indicator light◦ Control devices to regulate the x-ray beam
Time setting kVp setting mA setting
The Control Panel
![Page 6: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/6.jpg)
Control Panels
Older style Newer Design
![Page 7: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/7.jpg)
The extension arm suspends the x-ray tubehead and houses the electrical wires that extend from the control panel to the tubehead
The extension arm allows for movement and positioning of the tubehead
The Extension Arm
![Page 8: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/8.jpg)
Tubehead The tubehead is a
tightly sealed, heavy metal housing that contains the x-ray tube. The x-ray tube produces the dental x-rays
![Page 9: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/9.jpg)
The component parts of the tubehead include:◦ Metal housing◦ Insulating oil◦ Tubehead seal◦ X-ray tube◦ Transformer◦ Aluminum disk/filter◦ Lead collimator◦ Position Indicating Device (P.I.D.)
Tubehead
![Page 10: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/10.jpg)
Component Parts of the Tubehead
Metal Housing
The Metal Housing, or body, of the tubehead surrounds the x-ray tube and is filled with oil.
It protects the x-ray tube and grounds the high voltage components.
![Page 11: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/11.jpg)
Component Parts of the Tubehead Insulating Oil – the oil
that surrounds the x-ray tube.
It prevents overheating by absorbing the heat created when x-rays are produced
![Page 12: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/12.jpg)
Component Parts of the Tubehead Tubehead Seal – the
aluminum or leaded glass covering of the tubehead that permits the exit of x-rays from the tubehead.
It seals the oil in the tubehead
![Page 13: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/13.jpg)
Component Parts of the Tubehead The X-ray tube – the
heart of the x-ray generating system.
![Page 14: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/14.jpg)
Component Parts of the Tubehead Aluminum Disks –
sheets of 0.5 mm aluminum placed in the path of the x-ray beam.
This filters out the longer wavelength, non-penetrating x-rays.
Text – p. 15, Fig. 2-14
![Page 15: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/15.jpg)
Component Parts of the Tubehead Lead Collimator – a lead
plate with a central hole that fits directly over the opening of the metal housing where the x-rays exit the tubehead.
Restricts the size of the x-ray beam to 2.75 inches at the patient’s face.
![Page 16: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/16.jpg)
Component Parts of the Tubehead
Different tubehead lengths
Position Indicating Device (P.I.D.) – aims and shapes the x-ray beam as it exits the tubehead.
Sometimes called the “cone”
![Page 17: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/17.jpg)
Cathode is the negative electrode of the x-ray tube.
The purpose of the electrodes is to supply the electrons necessary to generate x-rays.
The cathode consists of:◦ Tungsten filament- generates the electrons that
produce the x-rays at the tungsten target◦ Molybdenum cup
Cathode
![Page 18: Reference Reading Chapter 2: pp. 15 - 17. X-rays are produced within the dental x-ray machine The x-ray machine can be divided into 3 study areas.](https://reader036.fdocuments.net/reader036/viewer/2022081700/56649db35503460f94aa34fa/html5/thumbnails/18.jpg)
The anode is the positive electrode within the x-ray tube
The purpose of the anode is to convert the electrons into x-ray photons at the tungsten target.
The anode consists of:◦ The tungsten target◦ The copper stem
Anode