REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

8
Narda-MITEQ The 1:1, dual 1:1 and 1:2 redundant low- noise amplifier (LNA) systems are designed to ensure continuous operation without disruption of signal transmission. A fault condition in the on-line LNA, or an operator generated command, will switch the standby LNA to the on-line position and remove the on-line LNA from the signal path. The redundant LNA system consists of an outdoor amplifier/switch assembly which mounts at the antenna hub, rack- mounted indoor local control unit and interconnection control cable. FEATURES • Low amplifier noise temperature • Fault tolerant design • Fully redundant, hot-swappable power supplies • Remote control via RS-485 or RS-422 user selectable • Automatic/manual control from both local and remote mode • Remote status • Off-line input/output access • Amplifier current fault detection • Weather resistant amplifier/switch plate assembly • Time-stamped alarm history • Front panel LNA bias display OPTIONS • Remote RS-232, Ethernet or contact closure • Transmit reject filter • Internal noise source • Input/output signal monitors • Higher gain • Increased output power • Remote control unit 1:1; DUAL 1:1 AND 1:2 SYSTEMS 1:1 Unit Dual 1:1 Unit 1:2 Unit REDUNDANT LOW-NOISE AMPLIFIER

Transcript of REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Page 1: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Narda-MITEQ

The 1:1, dual 1:1 and 1:2 redundant low-noise amplifier (LNA) systems are designed to ensure continuous operation without disruption of signal transmission.

A fault condition in the on-line LNA, or an operator generated command, will switch the standby LNA to the on-line position and remove the on-line LNA from the signal path.

The redundant LNA system consists of an outdoor amplifier/switch assembly which mounts at the antenna hub, rack- mounted indoor local control unit and interconnection control cable.

FEATURES

• Low amplifier noise temperature

• Fault tolerant design

• Fully redundant, hot-swappable power supplies

• Remote control via RS-485 or RS-422 user selectable

• Automatic/manual control from both local and remote mode

• Remote status

• Off-line input/output access

• Amplifier current fault detection

• Weather resistant amplifier/switch plate assembly

• Time-stamped alarm history

• Front panel LNA bias display

OPTIONS

• Remote RS-232, Ethernet or contact closure

• Transmit reject filter

• Internal noise source

• Input/output signal monitors

• Higher gain

• Increased output power

• Remote control unit

1 : 1 ; D U A L 1 : 1 A N D 1 : 2 S Y S T E M S

1:1 Unit

Dual 1:1 Unit

1:2 Unit

R E D U N D A N T L O W - N O I S EA M P L I F I E R

Page 2: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Narda-MITEQ

NOMENCLATURE FOR MODEL NUMBERS Low-noise amplifier system model numbers:Model number: LN (controller)-(frequency band abbreviation)-(amplifier noise temperature)Controller code: 1 = 1:1 Controller 2 = 1:2 Controller 3 = Dual 1:1 Controller

Please note that each low-noise amplifier system is supplied with: 1 Redundant amplifier/switch assembly 1 Local control and monitoring unit 1 100 foot interconnection control cable (other lengths optional)

Example: 1:1 system, 10.95 GHz to 12.75 GHz with 65 °K amplifier noise temperature: LN1-109128-65

Example: 1:2 system, 3.4 GHz to 4.2 GHz with 30 °K amplifier noise temperature: LN2-340420-30

Assembly enclosure option: To substitute a weather resistant enclosure for the standard weather resistant plate assembly add -W to end of part number. The weather resistant enclosure is recommended for mounting in a nonsheltered environment with direct rainfall.

Example: 1:2 system, 3.4 GHz to 4.2 GHz with 30 °K amplifier noise temperature in a weather resistant enclosure: LN2-340420-30-W

SPECIFICATIONS

FREQUENCY (GHz) BAND ABBREVIATIONAVAILABLE NOISE TEMPER-ATURE At +25 °C (Maximum) INTERFACE INPUT/OUTPUT

1.5 to 1.6 150160 33, 40, 60 SMA/SMA

2.0 to 2.4 200240 33, 40, 60 SMA/SMA

2.2 to 2.3 220230 33, 40, 60 SMA/SMA

3.4 to 4.2 340420 30, 35, 40, 50, 60 CPR-229G/N

3.4 to 4.8 340480 30*, 35*, 40, 50, 60 CPR-229G/N

3.62 to 4.205 362420 30, 35, 40, 50, 60 CPR-229G/N

3.6 to 4.8 360480 30*, 35*, 40, 50, 60 CPR-229G/N

4.5 to 4.8 450480 30, 35, 40, 50, 60 CPR-229G/N

7.1 to 8.4 710840 50*, 55, 60, 65 CPR-112G/SMA

7.25 to 7.75 725775 45, 50, 55, 60, 65 CPR-112G/SMA

8.0 to 8.4 800840 50*, 55, 60, 65 CPR-112G/SMA

10.7 to 12.75 107128 70, 80, 90, 100 WR-75/SMA

10.95 to 12.75 109128 65, 70, 80, 90, 100 WR-75/SMA

10.95 to 11.70 109117 65, 70, 80, 90, 100 WR-75/SMA

11.70 to 12.75 117128 65, 70, 80, 90, 100 WR-75/SMA

17.7 to 21.2 177212 120*, 140, 160 WR-42/SMA

17.7 to 22.0 177220 130*, 140, 160 WR-42/SMA

18.7 to 20.3 187203 120*, 140, 160 WR-42/SMA

20.2 to 21.2 202212 120*, 140, 160 WR-42/SMA

* References 14 dB minimum input return loss specification.

R E D U N D A N T L O W - N O I S EA M P L I F I E R

Page 3: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

1.0 dB peak-to-peak/RF bands up to 500 MHz, 1.5 dB peak-to-peak/RF bands up to 800 MHz, 2.0 dB peak-to-peak/RF bands greater than 800 MHzGain slope ..........................................................................0.2 dB/10 MHz maximumGain stability ......................................................................±0.2 dB/24 hours (constant temperature), 5 dB maximum/-40 °C to +60 °C (higher stability optional)Power output (1 dB compression) .....................................+10 dBm minimum (higher output power optional)AM/PM conversion ............................................................0.5°/dB maximum to 0 dBm outputGroup delay (±18 MHz) Linear ............................................................................0.02 ns/MHz maximum Parabolic .......................................................................0.001 ns/MHz2 maximum Ripple ............................................................................0.1 ns peak-to-peak maximum Spurious outputs ...............................................................Below thermal noiseIsolation .............................................................................50 dB minimumInput return loss ................................................................19 dB minimum, *14 dB minimum (refer to table on previous page)Output return loss ..............................................................20 dB minimumInput/output impedance ....................................................50 ohmsSwitchover time .................................................................100 ms maximumNondamage input power ...................................................+10 dBm maximumTransmit desensitivity threshold C-Band .......................................................................... -20 dBm maximum (-30 dBm with Option 11) C-Band (3.4 GHz to 4.8 GHz) ......................................... -45 dBm maximum (-55 dBm with Option 11) X-Band .......................................................................... -50 dBm maximum (-60 dBm with Option 11) Ku-Band ........................................................................ -20 dBm maximum (-30 dBm with Option 11) Ka-Band ........................................................................ -50 dBm maximum (-60 dBm with Option 11)

LOCAL CONTROL UNIT PRIMARY POWER REQUIREMENTSVoltage ...............................................................................90 VAC to 250 VACFrequency ..........................................................................47 Hz to 63 HzPower consumption ...........................................................20 W typical, 50 W peak during switchover

SUMMARY ALARMContact closure/open for DC voltage and/or amplifier alarm.Status alarm readout on remote control bus.

PHYSICALAC input connectors .......................................................... IEC-320Summary alarm interface mating connector. .....................DEM-9PRemote interface connector ..............................................DEM-9S for RS-485 and RS-422, DB-25P for RS-232, DB-37S for contact closureSwitch/amplifier weight (does not apply to weather resistant housing option) 1:1 units .........................................................................Below 10 GHz 15 lb. above 10 GHz 10 lb. nominal 1:2 units .........................................................................Below 10 GHz 25 lb. above 10 GHz 20 lb. nominal

ENVIRONMENTALOperating Ambient temperature (Controller) ..................................0 °C to 50 °C Ambient temperature (Amplifier assembly) ................... -40 °C to +60 °C (other ranges available, consult factory) Atmospheric pressure ...................................................Up to 10,000 feetNonoperating Temperature .................................................................. -50 °C to 70 °C Atmospheric pressure ...................................................Up to 40,000 feet Shock and vibration .................................................... Normal handling by commercial carriers

SPECIFICATIONS (CONTINUED)RF SPECIFICATIONSGain ...................................................................................50 dB minimum, 52 dB typical (higher gain optional)Gain flatness ......................................................................0.4 dB/40 MHz,

Page 4: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Narda-MITEQ

STANDARD WAVEGUIDE FLANGES

CONTROLLER REAR-PANEL VIEW

OPTION 1

-40 dBc

A1

A2

-20 dBc

STANDBYINPUT

STANDBYOUTPUT

OPTION 3 OPTION 2

RF OUTPUT

RFINPUT

TRANSMITREJECTFILTER

3.882.9162.290

1.1451.771

2.75

.5501.620

2.6903.240

#1/4-20 x 0.31 DP(TYP. 10 PLACES)

WR-229 CPR-G FLANGE

.550

2.1001.5501.050

1.500 SQ..750

.375

.5201.040

#6-32 x 0.25 DP(TYP. 4 PLACES)

WR-75 GROOVED FLANGE

NOTE:FLANGES NOT DRAWN TO SIZE

.5611.122

2.501.3721.122

.497.7471.75

.578.953

1.3281.906

#8-32 x 0.25 DP(TYP. 8 PLACES)

WR-112 CPR-G FLANGE

.328

1.281.953.640

.875 SQ..420

.170

.320.640

#4-40 x 0.25 DP(TYP. 4 PLACES)

WR-42 GROOVED FLANGE WR-28 GROOVED FLANGE

.335.670

.750 SQ..280

.140

.250.500

# 4-40 x 0.25 DP(TYP. 4 PLACES)

.265.530

1:1 AND 1:2 CONTROLLER

DUAL 1:1 CONTROLLER

Ground Lug Power supply AAC Voltage

input/switch

Power supply BAC Voltage

input/switch

Summary alarm

connector

Remote inter face

connector

Amplif ier assemblyinter face connectors

LNA 1inter face

LNA 2inter face

NOTE: FLANGES NOT DRAWN TO SIZE.

R E D U N D A N T L O W - N O I S EA M P L I F I E R

Page 5: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

1:1 REDUNDANT LNA SYSTEM BLOCK DIAGRAM

1:2 REDUNDANT LNA SYSTEM BLOCK DIAGRAM

OPTION 1

-40 dBc

A1

A2

-20 dBc

STANDBYINPUT

STANDBYOUTPUT

OPTION 3 OPTION 2

RF OUTPUT

RFINPUT

TRANSMITREJECTFILTER

3.882.9162.290

1.1451.771

2.75

.5501.620

2.6903.240

#1/4-20 x 0.31 DP(TYP. 10 PLACES)

WR-229 CPR-G FLANGE

.550

2.1001.5501.050

1.500 SQ..750

.375

.5201.040

#6-32 x 0.25 DP(TYP. 4 PLACES)

WR-75 GROOVED FLANGE

NOTE:FLANGES NOT DRAWN TO SIZE

.5611.122

2.501.3721.122

.497.7471.75

.578.953

1.3281.906

#8-32 x 0.25 DP(TYP. 8 PLACES)

WR-112 CPR-G FLANGE

.328

1.281.953.640

.875 SQ..420

.170

.320.640

#4-40 x 0.25 DP(TYP. 4 PLACES)

WR-42 GROOVED FLANGE WR-28 GROOVED FLANGE

.335.670

.750 SQ..280

.140

.250.500

# 4-40 x 0.25 DP(TYP. 4 PLACES)

.265.530

1

0

1

0

J1

J2J3

RMTINTFC

SUM ALM

1

0

1

0

J1

J2J3

RMTINTFC

SUM ALM

A1

STANDBYOUTPUT

-20 dBc

OPTION 2

A2

STANDBYINPUT

A3

OPTION 1

-40 dBc

OPTION 3

RF INPUT 1

OPTION 1

-40 dBc

OPTION 3

RF INPUT 2

Ground lug Power supply AAC voltageinput/switch

-20 dBc

OPTION 2WAVE-GUIDE

W2

WAVE-GUIDE

W1

Power supply BAC voltageinput/switch

Summary alarmconnector

Remoteinterface

connectors

Amplifier assemblyinterface

connectors

1

0

1

0

J1

J2J3

RMTINTFC

SUM ALM

TRANSMITREJECTFILTER

TRANSMITREJECTFILTER

RF OUTPUT 2

RF OUTPUT 1

Typical system noise temperature calculation:1:1 Redundant System: Tsystem = TLNA + TSWITCH + TOPTION 3 + TOPTION 1

1:2 Redundant LNA System: RF input 1: LNA 1 on-line signal path Tsystem = TLNA + TSWITCH + TOPTION 3 + TOPTION 1 RF input 1: LNA 3 on-line signal path (LNA 1 standby) Tsystem = TLNA + 2*TSWITCH + TW2 + TOPTION 3 + TOPTION 1

RF input 2: LNA 2 on-line signal path Tsystem = TLNA + TW1 + TSWITCH + TOPTION 3 + TOPTION 1 RF input 1: LNA 3 on-line signal path (LNA 2 standby) Tsystem = TLNA + 2*TSWITCH + TW1 + TW2 + TOPTION 3 + TOPTION 1

Typical Noise Temperature in Kelvin (°K) at 23 °CBand (GHz) 0 to 0.95 0.95 to 2 3.62 to 4.205 3.4 to 4.2 & 4.5 to 4.8 7.2 to 7.8 10.7 to 12.75 17.7 to 22.0 27.5 to 33

(coaxial) WR-229 WR-229 WR-112 WR-75 WR-42 WR-28

TSWITCH 7.0 ° 13.5 ° 1.5 ° 1.5 ° 3 ° 5 ° 12 ° 20 °

TW1 N/A N/A 1.5 ° 1.5 ° 4 ° 4 ° 7 ° 10 °

TW2 14 ° 14 ° 1.5 ° 1.5 ° 9 ° 9 ° 11 ° 15 °

TOPTION 1 25 ° 25 ° 0.5 ° 0.5 ° 2 ° 2 ° 3 ° 4 °

TOPTION 3 N/A N/A 3.0 ° 7.5 ° 28 ° 15 ° N/A N/A

Page 6: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Narda-MITEQ

1:1 Ku-BAND AMPLIFIER

1:2 Ku-BAND AMPLIFIER ASSEMBLY

OUTLINE DRAWINGS

OUTLINE DRAWING,1:1 REDUNDANT LNA UNIT,

LN1-145943-XX

187596 B

8.000 [203.20]

9.00 [228.60]

.50 [12.70]

SMA FEMALECONNECTOR (4X)

10.00 [254.00]

7.69 [195.30]MAXIMUM

3.76[95.50]

4.82[122.43]

2.26[57.40]

9.000 [228.60].50[12.70]

2.38 [60.35]

5.88[149.35]

PLATE ASSEMBLYTO CONTROL UNIT

INTERFACE CONNECTOR

3.15

.511.61

6.89 [175.00]

.25[6.35]

1.05[26.67]

.00

.50

.25 [6.35]

4.50[114.30]

6.94 [176.28]

3.50[88.90]

J6 OUTPUT MONITOR(OPTION 2 ONLY)

4X Ă.281 [Ă7.14]

J2J4

J5

J3

RF

OU

TPUT

OU

TPUT

STAND

BYIN

PUT

STAND

BYCO

NTR

OLLER

INTER

FACE

(-1)

(-3)

LNA

UN

IT1:

1 R

EDU

ND

AN

T

J6

MO

NITO

RO

UTPU

T

LNA PLATE ASSY1:1 Ku-BANDUSED FOR:145943-101Similar to:145995-115 (Ku-Band)145943-106 (X-Band)NEW LAYOUT USING BOTH:THE -115 & -106P.Crocitto 7/16/2012

OUTLINE DRAWING1:2 REDUNDANT LNA

Ku-BAND

207235 B

J5

A2A3

OU

TPUT 2

OU

TPUT 2

MO

NITO

R

OU

TPUT 1

MO

NITO

R

OU

TPUT 1

J9 J4 J8 J2

CO

NTR

OLLER

INTER

FAC

E

J7

INP

UT

OU

TPU

T

STA

ND

BY

STA

ND

BY

J6

INPU

TS

TAN

DB

Y

OU

TPUT

STA

ND

BY

J5 OU

TPUT 2

J4 OU

TPUT 1

J2

CO

NTR

OLLER

INTER

FAC

E

J7

1:2 REDUNDANTLNA UNIT

RF I

NR

J1 2

J6

1

9.000 [228.60]

10.00 [254.00].50

[12.70]

8.000 [203.20]

2.30 [58.43]

4.00 [101.60]

(8.000)9.00

[228.60]20.50+1.0

3.50 [88.90]

1.75 [44.45]

1.43 [36.32]

7.57 [192.28]

1.29 [32.64]

3.41 [86.49]4.47 [113.41]

1.74 [44.07] 3.42

[86.74]4.48

[113.67]5.77 [146.64]

7.69 [195.30]

.50 [12.70]

MOUNTING PLATE WR42 WAVEGUIDERF INPUT 2

WAVEGUIDE

RF INPUT 1WR75

TRANSMIT REJECT FILTER(OPTION 3 ONLY)

4X Ø.281

SMA, FEMALE,CONNECTORS

2.35 [59.56]

8.69 [220.60]

TEST INPUTINJECT COUPLER(OPTION 1 ONLY)

OPTION 2

NO OPTIONS

PLATE ASSEMBLY TO CONTROL UNIT INTERFACE CONNECTOR

Note: Dimensions shown are in inches and those shown in brackets [ ] are in millimeters.

R E D U N D A N T L O W - N O I S EA M P L I F I E R

Page 7: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Ka-BAND AMPLIFIER ASSEMBLY OUTLINE DRAWING

1:2 Ka-BAND AMPLIFIER ASSEMBLY

Note: Dimensions shown are in inches and those shown in brackets [ ] are in millimeters.

LN1 SERIES (Ka-BAND)

199708 AREV.

8.50 [215.90]

INTER

FACECO

NTR

OLLER

OU

TPUT

STAND

BYSTAN

DBY

J6

MO

NITO

RO

UTPU

T

J4

INPU

T

J2

OU

TPUT

RF

J5

J3

10.00 [254.00]

9.000 [228.60]

1.05[26.67] OUTPUT MONITOR

(OPTION 2 ONLY)

8.000 [203.20]

9.00 [228.60]

6.89[175.00]

.25[6.35]

.50 [12.70]

2.38[60.35]

2.26[57.40]

6.94[176.28]

3.76[95.50]4.82

[122.43]5.88[149.35]

6.30[160.00]MAXIMUM .50 [12.70]

WITHOUT TERMINATION

SMA FEMALECONNECTOR (1X)

SMA FEMALE

WITH TERMINATIONCONNECTOR (3X)

TRANSMIT REJECTFILTER(OPTION 3 ONLY)

TEST INPUTINJECT COUPLER(OPTION 1 ONLY)

.25 [6.35]

RF INPUTWR-42

4X Ǿ.265

PORT

1

2.13[53.98]

2.50[63.50]

LNA

UN

IT1:

1 R

EDU

ND

AN

T

RF

INP

UT

1

PLATE ASSEMBLY TO CONTROL UNIT INTERFACE CONNECTOR

OUTLINE DRAWING1:2 REDUNDANT LNA UNIT

LN2 SERIES (Ka-BAND)

199764 AREV.

.50 [12.70]

.50[12.70]

12.00[304.80]

11.00[279.40]

1.14 [28.96]

9.92[251.94]

2.25[57.15]

10.53 [267.34]

7.37 [187.07]

3.22[81.79]

TEST INJECT COUPLER (OPTION 1 ONLY)

12.00 [304.80]

11.00 [279.40]

2.25 [57.10]

Ø.257 THRU4 PLACES

.50[12.70]

2.40[60.96]

1.24 [31.40]

5X .64 [16.26]

4.43 [112.43]

.25 [6.35]

5.50 [139.70]

5.30 [134.52]

[139.70]

.25 [6.35]

1.00 1.50[35.10]

2.00[50.80]

[19.08]

.75 [19.08]

[9.55]7.37 [187.07]

SMA, FEMALE6 PLACES

(OPTION 3 ONLY)TRANSMIT REJECT FILTER

(OPTION 2 ONLY)

.38

CO

NTR

OLLER

INTER

FAC

E

J8 J2J4J9

STA

ND

BY

INP

UT

STA

ND

BY

OU

TPU

T

MO

NITO

RO

UTP

UT 1

MO

NITO

RO

UTP

UT 2

OU

TPU

T 2

OU

TPU

T 1

J5J6

1:2

RED

UN

DA

NT

LNA

UN

IT

5.50

.75

PLATE ASSEMBLY TO CONTROL UNIT INTERFACE CONNECTOR

RF

INP

UT

1R

F IN

PU

T 2

OUTLINE DRAWINGS (CONTINUED)

Page 8: REDUNDANT LOW-NOISE AMPLIFIER - Narda-MITEQ

Missing option numbers are not applicable for this product. Note: System noise temperature will increase and return loss will degrade for any additional component located before the amplifier. This applies to Options 1 and 3. 1. Test input inject couplers Below 3.4 GHz, coaxial coupler 40 dB nominal coupling level. Above 3.4 GHz, crossguide coupler 40 dB nominal coupling level. 2. Output test coupler 20 dB nominal coupling level 3. Transmit reject filter

OPTIONS

RECEIVE BAND FREQUENCY (GHz)

RECEIVE BAND INSERTION LOSS

TRANSMIT BAND FRE-QUENCY (GHz)

TRANSMIT BAND REJECTION

3.4 to 4.2 0.04 dB 5.825 to 6.725 60 dB

3.62 to 4.205 0.04 dB 5.825 to 6.425 55 dB

3.6 to 4.8 0.10 dB 5.85 to 7.05 60 dB

4.5 to 4.8 0.15 dB 6.70 to 7.05 55 dB

7.25 to 7.75 0.5 dB 7.9 to 8.4 64 dB

10.7 to 12.75 0.15 dB 13.75 to 14.5 (17.3 to 18.4*) 60 dB

10.95 to 12.75 0.1 dB 14.0 to 14.5 (17.3 to 18.4*) 70 dB

17.7 to 21.2 0.25 dB 27.0 to 31.0 70 dB

* For 17.3 GHz to 18.4 GHz band, Option 3 becomes Option 3-DBS.

4. Noise source 15 dB ENR nominal. Local and remote control provided. 6-(x). Local control unit to amplifier/switch assembly cable length, where (x) is the length of the cable in feet. Available from 10 feet to 400 feet in 10 foot increments. 100 foot cable supplied as standard. 11. Increased gain 60 dB minimum gain 12. Increased output power +20 dBm output power at 1 dB compression 13. Increased gain stability 3 dB peak-to-peak maximum/-40 °C to +60 °C 17. Remote control B. RS-422/RS-485 (supplied as standard) C. RS-232 D. Contact closure H. Ethernet 22. Dedicated remote control panel Provides remote control over a dedicated RS-422/RS-485 bus. Option 17B (RS-422/RS-485 remote bus) must be ordered.

435 Moreland Road

Hauppauge, NY 11788

Tel: 631-231-1700

Fax: 631-231-1711

Email : [email protected]

www.nardamiteq.com

This material consists of Narda-MITEQ general capabilities information and does not contain controlled technical data as defined within the International Traffic in Arms (ITAR) Part 120.10 or Export Administration Regulations (EAR) Part 734.7-11. D-235F/01.23.17

The material presented in this datasheet was current at the time of publication. Narda-MITEQ’s continuing product improvement program makes it necessary to reserve the right to change our mechanical and electrical specifications without notice. If either of these parameters is critical, please contact the factory to verify that the information is current.

Note: For literature describing local control and remote control (bus protocols), refer to Narda-MITEQ Technical Note 25T042.

R E D U N D A N T L O W - N O I S EA M P L I F I E R