REAR ELEVATION NOT FOR CONSTRUCTION · PDF file rear elevation n/a jim love and laura mcdonald...

Click here to load reader

  • date post

    11-Aug-2020
  • Category

    Documents

  • view

    0
  • download

    0

Embed Size (px)

Transcript of REAR ELEVATION NOT FOR CONSTRUCTION · PDF file rear elevation n/a jim love and laura mcdonald...

  • DN

    123

    LEVEL 1 0' - 0"

    LEVEL 2 13' - 0"

    LEVEL 3 27' - 0"

    LEVEL 4 40' - 0"

    9' - 4 15/16" 9' - 2 11/16"

    18' - 7 5/8"

    1 3

    ' - 0

    " 1

    4 ' -

    0 "

    1 3

    ' - 0

    "

    123

    LEVEL 1 0' - 0"

    LEVEL 2 13' - 0"

    LEVEL 3 27' - 0"

    LEVEL 4 40' - 0"

    9' - 4 15/16" 9' - 2 11/16"

    18' - 7 5/8"

    1 3

    ' - 0

    " 1

    4 ' -

    0 "

    1 3

    ' - 0

    "

    727 94

    726 94

    729 95

    728 95

    751 96

    PROPOSED DRYER

    EXHAUST VENT 6" DUCT

    WITH MATTE BLACK VENT

    CAP 36" FROM ANY

    OPENING

    PROPOSED ERV EXHAUST

    VENT 6" DUCT WITH MATTE

    BLACK VENT CAP

    PROPOSED VENT FOR ERV

    INTAKE 6" DUCT WITH MATTE

    BLACK VENT CAP

    A203 1

    0 ' -

    8 "

    1 0

    ' - 4

    1 /2

    "

    8" 46 7/8" 8" 47 1/2" 8" 51 1/2"

    PROPOSED ERV INTAKE VENT

    PROPOSED DRYER EXHAUST VENT

    PROPOSED ERV EXHUAST VENT

    Scale

    Project number

    Date

    Drawn by

    Checked by

    KEY PLAN:

    Project Status

    SAM KACHMAR ARCHITECTS2019C SAM KACHMAR

    ARCHITECTS

    (p)978-270-8441 kachmardesign.com 357 HURON AVE.

    CAMBRIDGE MA, 02138

    N O

    T F

    O R

    C O

    N S

    T R

    U C

    T IO

    N

    As indicated

    7 /2

    /2 0

    1 9 1

    :4 1

    :3 9

    P M

    A201

    R E

    A R

    E L E

    V A

    T IO

    N

    N/A

    L O

    V E

    / M

    c D

    O N

    A L D

    R E

    S ID

    E N

    C E

    J IM

    L O

    V E

    A N

    D L

    A U

    R A

    M c D

    O N

    A L D

    06/28/2019

    MNW

    Checker

    3 4 C

    O M

    M O

    N W

    E A

    L T

    H A

    V E

    , B

    O S

    T O

    N , M

    A , 0 2 1 1 6

    CONSTRUCTION DOCUMENTS

    1/4" = 1'-0" 1

    REAR ELEVATION - EXISTING 1/4" = 1'-0"

    2 REAR ELEVATION - PROPOSED

    4 ENLARGED AXON - REAR ELEVATION

    EXISTING IMAGE OF OTHER VENTS THROUGHOUT

    THE BACK ALLEY OF COMMONWEALTH AVE

    (PUBLIC ALLEY 437) - VENT STYLED TO MATCH

  • 2

    LEVEL 3 27' - 0"

    8 "

    2 2 3

    /4 "

    17" 8" 17"17 1/4" 8" 17 1/4"

    VENTS ALIGNED CENTERED

    ABOVE THE WINDOW AND

    DOOR

    VENTS ALIGNED AT SAME

    HEIGHT - TO ACHIEVE

    REQUIRED OFFSET FROM

    OPENING ON THE FACADE

    8 "

    1 2 4 1

    /2 "

    46 1/2"41 5

    /1 6"

    8"47 1/2"8"46 7/8"8"

    1 0

    ' - 8

    1 /2

    "

    8 "

    2 8 1

    /2 "

    PROPOSED DRYER

    EXHAUST VENT 6" DUCT

    WITH MATTE BLACK VENT

    CAP 36" FROM ANY

    OPENING

    PROPOSED ERV EXHAUST

    VENT 6" DUCT WITH MATTE

    BLACK VENT CAP

    PROPOSED VENT FOR ERV

    INTAKE 6" DUCT WITH MATTE

    BLACK VENT CAP

    PROPOSED DRYER

    EXHAUST VENT 6" DUCT

    WITH MATTE BLACK VENT

    CAP 36" FROM ANY

    OPENING

    PROPOSED ERV EXHAUST

    VENT 6" DUCT WITH MATTE

    BLACK VENT CAP

    PROPOSED VENT FOR ERV

    INTAKE 6" DUCT WITH MATTE

    BLACK VENT CAP

    F

    1 0

    ' - 0

    "

    1 0

    7 /8

    "

    6 "

    EXISTING

    CEILING -

    DEMOLISHED

    6" VENTS WITH

    EXTERIOR INTAKES

    OR EXHAUSTS

    PROPOSED 10'

    TALL CEILING TO

    ACCOMIDATE

    DUCTWORK

    6 "

    1 2

    5 1

    /2 "

    2 3

    3 /4

    "

    2"

    Scale

    Project number

    Date

    Drawn by

    Checked by

    STRUCTURAL ENGINEER:

    REGISTRATIONS:

    Project Status

    SAM KACHMAR ARCHITECTS2019C SAM KACHMAR

    ARCHITECTS

    (p)978-270-8441 kachmardesign.com 357 HURON AVE.

    CAMBRIDGE MA, 02138

    N O

    T F

    O R

    C O

    N S

    T R

    U C

    T IO

    N

    1/2" = 1'-0"

    7 /2

    /2 0

    1 9 1

    :4 1

    :4 2

    P M

    A203

    R E

    A R

    E L E

    V A

    T IO

    N -

    V E

    N T

    D E

    T A

    IL S

    N/A

    L O

    V E

    / M

    c D

    O N

    A L D

    R E

    S ID

    E N

    C E

    J IM

    L O

    V E

    A N

    D L

    A U

    R A

    M c D

    O N

    A L D

    06/28/2019

    Author

    Checker

    3 4 C

    O M

    M O

    N W

    E A

    L T

    H A

    V E

    , B

    O S

    T O

    N , M

    A , 0 2 1 1 6

    CONSTRUCTION DOCUMENTS

    1/2" = 1'-0" 1

    REAR ELEVATION - PROPOSED - VENTING DETAILS

    2 ENLARGED AXON - REAR ELEVATION VENTS

    EXISTING DECK PHOTO

    1/2" = 1'-0" 3

    VENTS SIDE ELEVATION

    PROPOSED

    RENDERS OF

    BACK DECK &

    PROPOSED ERV /

    DRYER INTAKE

    AND EXHUAST

    VENTS