DN
123
LEVEL 1 0' - 0"
LEVEL 2 13' - 0"
LEVEL 3 27' - 0"
LEVEL 4 40' - 0"
9' - 4 15/16" 9' - 2 11/16"
18' - 7 5/8"
1 3
' - 0
" 1
4 ' -
0 "
1 3
' - 0
"
123
LEVEL 1 0' - 0"
LEVEL 2 13' - 0"
LEVEL 3 27' - 0"
LEVEL 4 40' - 0"
9' - 4 15/16" 9' - 2 11/16"
18' - 7 5/8"
1 3
' - 0
" 1
4 ' -
0 "
1 3
' - 0
"
727 94
726 94
729 95
728 95
751 96
PROPOSED DRYER
EXHAUST VENT 6" DUCT
WITH MATTE BLACK VENT
CAP 36" FROM ANY
OPENING
PROPOSED ERV EXHAUST
VENT 6" DUCT WITH MATTE
BLACK VENT CAP
PROPOSED VENT FOR ERV
INTAKE 6" DUCT WITH MATTE
BLACK VENT CAP
A203 1
0 ' -
8 "
1 0
' - 4
1 /2
"
8" 46 7/8" 8" 47 1/2" 8" 51 1/2"
PROPOSED ERV INTAKE VENT
PROPOSED DRYER EXHAUST VENT
PROPOSED ERV EXHUAST VENT
Scale
Project number
Date
Drawn by
Checked by
KEY PLAN:
Project Status
SAM KACHMAR ARCHITECTS2019C SAM KACHMAR
ARCHITECTS
(p)978-270-8441 kachmardesign.com 357 HURON AVE.
CAMBRIDGE MA, 02138
N O
T F
O R
C O
N S
T R
U C
T IO
N
As indicated
7 /2
/2 0
1 9 1
:4 1
:3 9
P M
A201
R E
A R
E L E
V A
T IO
N
N/A
L O
V E
/ M
c D
O N
A L D
R E
S ID
E N
C E
J IM
L O
V E
A N
D L
A U
R A
M c D
O N
A L D
06/28/2019
MNW
Checker
3 4 C
O M
M O
N W
E A
L T
H A
V E
, B
O S
T O
N , M
A , 0 2 1 1 6
CONSTRUCTION DOCUMENTS
1/4" = 1'-0" 1
REAR ELEVATION - EXISTING 1/4" = 1'-0"
2 REAR ELEVATION - PROPOSED
4 ENLARGED AXON - REAR ELEVATION
EXISTING IMAGE OF OTHER VENTS THROUGHOUT
THE BACK ALLEY OF COMMONWEALTH AVE
(PUBLIC ALLEY 437) - VENT STYLED TO MATCH
2
LEVEL 3 27' - 0"
8 "
2 2 3
/4 "
17" 8" 17"17 1/4" 8" 17 1/4"
VENTS ALIGNED CENTERED
ABOVE THE WINDOW AND
DOOR
VENTS ALIGNED AT SAME
HEIGHT - TO ACHIEVE
REQUIRED OFFSET FROM
OPENING ON THE FACADE
8 "
1 2 4 1
/2 "
46 1/2"41 5
/1 6"
8"47 1/2"8"46 7/8"8"
1 0
' - 8
1 /2
"
8 "
2 8 1
/2 "
PROPOSED DRYER
EXHAUST VENT 6" DUCT
WITH MATTE BLACK VENT
CAP 36" FROM ANY
OPENING
PROPOSED ERV EXHAUST
VENT 6" DUCT WITH MATTE
BLACK VENT CAP
PROPOSED VENT FOR ERV
INTAKE 6" DUCT WITH MATTE
BLACK VENT CAP
PROPOSED DRYER
EXHAUST VENT 6" DUCT
WITH MATTE BLACK VENT
CAP 36" FROM ANY
OPENING
PROPOSED ERV EXHAUST
VENT 6" DUCT WITH MATTE
BLACK VENT CAP
PROPOSED VENT FOR ERV
INTAKE 6" DUCT WITH MATTE
BLACK VENT CAP
F
1 0
' - 0
"
1 0
7 /8
"
6 "
EXISTING
CEILING -
DEMOLISHED
6" VENTS WITH
EXTERIOR INTAKES
OR EXHAUSTS
PROPOSED 10'
TALL CEILING TO
ACCOMIDATE
DUCTWORK
6 "
1 2
5 1
/2 "
2 3
3 /4
"
2"
Scale
Project number
Date
Drawn by
Checked by
STRUCTURAL ENGINEER:
REGISTRATIONS:
Project Status
SAM KACHMAR ARCHITECTS2019C SAM KACHMAR
ARCHITECTS
(p)978-270-8441 kachmardesign.com 357 HURON AVE.
CAMBRIDGE MA, 02138
N O
T F
O R
C O
N S
T R
U C
T IO
N
1/2" = 1'-0"
7 /2
/2 0
1 9 1
:4 1
:4 2
P M
A203
R E
A R
E L E
V A
T IO
N -
V E
N T
D E
T A
IL S
N/A
L O
V E
/ M
c D
O N
A L D
R E
S ID
E N
C E
J IM
L O
V E
A N
D L
A U
R A
M c D
O N
A L D
06/28/2019
Author
Checker
3 4 C
O M
M O
N W
E A
L T
H A
V E
, B
O S
T O
N , M
A , 0 2 1 1 6
CONSTRUCTION DOCUMENTS
1/2" = 1'-0" 1
REAR ELEVATION - PROPOSED - VENTING DETAILS
2 ENLARGED AXON - REAR ELEVATION VENTS
EXISTING DECK PHOTO
1/2" = 1'-0" 3
VENTS SIDE ELEVATION
PROPOSED
RENDERS OF
BACK DECK &
PROPOSED ERV /
DRYER INTAKE
AND EXHUAST
VENTS
Sheets A201 - REAR ELEVATION A203 - REAR ELEVATION - VENT DETAILS