Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology:...

35
1 ICT Biomedical sensor technology: state - of the art and future roadmap Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology

Transcript of Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology:...

Page 1: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

1ICT

Biomedical sensor technology: state - of the art and future roadmap

Ralph W. BernsteinSINTEF ICT

Microsystems and nanotechnology

Page 2: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

2ICT

MiNaLabClean room area:SINTEF: 800 m2

University of Oslo: 600 m2

Micro environments, class 10A full silicon processing line for MEMS and radiation detectorsCapacity of 10.000 6”wafers/year Located at the campus of University of Oslo240 MNOK invested in scientific equipment and laboratory infrastructure Funded by Norwegian Research Council and SINTEF

Page 3: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

3ICT

Moores law

Gordon Mooresobservation from 1965: The number of transistors per square inch on an IC doubles every year.In subsequent years, the pace has slowed down a bit, but data density has doubled every 18 months.

Gordon Moore, Electronics, Volume 38, Number 8, April 19, 1965

Page 4: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

4ICT

Key technologies

UV-Light

Mask

Pattern transferred to wafer

Lence

Silicon wafer

Micro processor

Photo lithographyBatch production

Page 5: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

5ICT

Driving forcesCheaper

Cost per function decreases 25% / year

SmallerMoore's law: bits/chip grow by factor of 4 times every 3 years

Faster5 times growth every 10 years

Even more important: FUNCTIONALITY !

Page 6: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

6ICT

From the information society towards the instrumentation society

Microelectronics is the first industrial wave based on microtechnology. The next one, microsystems, will have great impact the next 5-10 years.

Microsystems perform measurements, signal conditioning and actuation

I the future the electronics will be connected direct to the environment via sensors => Ambient intelligence

The keys to this development:Low cost computer powerWireless communicationModern sensorsDistributed power generation

Same challenges for the biomedical area !!

Page 7: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

7ICT

Microsystem technology

Utilizes the production technology developed for microelectronics to make sensors (MEMS)

MiniaturizationHigh volume, low cost productionIntegration with electronics

Special processesMicromachining Functional thin filmsWafer stacking

Page 8: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

8ICT

Why silicon technology

Batch processing => low cost, high volumeWell established production technologyAdvanced infrastructure, materials and design tools available Wide range of sensor principles availableSilicon has attractive mechanical propertiesIntegration with electronics possible

Polymers are also important

Page 9: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

9ICT

A sensor converts stimuli to electricity

Optical sensor- +

Pressure sensor

Chemical sensor (ISFET)

Piezo resistors

p-n junction

Membrane

Page 10: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

10ICT

Pressure sensorsMeasure pressure gradients across heart valves accurately to help assess valve disease

Diagnose and monitor congestive heart failure Measure cardiac output and compliance

Monitor intracranial pressures in hydrocephalus patients

Understand glaucoma disease progression and improve patient care

Improve gastrointestinal tract diagnostic capabilities to help treat gastro esophageal reflux disease (GERD)

Assist in diagnosis of urological disorders

Measure drug delivery rate for infusion systems

Page 11: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

11ICT

Micromaching of 3D mechanical structuresfor mechanical sensors

Page 12: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

12ICT

Micro tools

TORSIONALHINGES

100 µm

MEMS PI

Page 13: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

13ICT

Micro and nano cantilever sensors

A. Tixier-Mitaa, Y. Mitab and Hiroyuki Fujitaa The University of Tokyo,

Page 14: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

14ICT

Market surveys and roadmapsNEXUS

20002005

Page 15: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

15ICT

Open consultation on the European Strategy for nanotechnology(December 2004)

Page 16: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

16ICT

Large R&D focus at implanted sensors

Reduce Surgical TraumaShorten Patient Recovery TimesEnhance Patient Quality of Life Increase Life ExpectancyReduce Healthcare & Social Care Costs

Page 17: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

17ICT

Therapeutic MEMS examples

Page 18: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

18ICT

Current commercial and research status

Page 19: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

19ICT

Commercial statusMost mature MEMS areas

Cardiovascularwhere pacemakers are gradually being supplemented by other devices such as defibrillators, and ventricular assist devices.

Neurologywhere neurostimulators are used to treat a wide range of neurological conditions.

Otologybased primarily on cochlear implants for sensorineural deafness.

Oncologyprimarily through the use of programmable drug infusion devices.

Diabetes (endocrinology)Insulin pumps, mainly

Page 20: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

20ICT

Highest research activity expected: 8 areas

CardiovascularDrug deliveryEndocrinologyGastroenterologyNeurologyOtologyRehabilitative medicineSurgery

Page 21: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

21ICT

Research challenges

Page 22: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

22ICT

Cardiovascular

Page 23: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

23ICT

Drug delivery

Page 24: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

24ICT

Endocrinology

Page 25: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

25ICT

Gastroenterology

Page 26: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

26ICT

Neurology

Page 27: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

27ICT

Otology

Page 28: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

28ICT

Rehabilitative medicine

Page 29: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

29ICT

Surgery

Page 30: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

30ICT

Activities at SINTEF ICT.

Measurement of inter cranial-pressure

Page 31: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

31ICT

Solid state silicon radiation detectorsfor medical imaging.Micro strip detectors for mammographyPixel detectors for dental x-rayPixel detectors for CT scanning.Micro strip detectors for screening of isotope labeled nucleotides

Mamea Imaging AB

Page 32: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

32ICT

Stent graft sensingAAA: Abdominal Aortic AneurismMission - improving the long term reliability of AAA stent graftsThe Product - introducing an add-on to the AAA stent grafts to enable a real time monitoring device to alert for possible sudden rupture and endo-leaks.

Orhere

Page 33: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

33ICT

Lab-on-a-chip for diagnostics based on mRNA anaylsis

Microfluidic handlingReal-time RNA amplification Fluorescent read-out.

Page 34: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

34ICT

Flow sensorApplication: Reagents flow measurements, dosing of drugsFluid flow through chipDifferential pressure sensorProtected conductors/resistors

Typical flow rate 5 µl/minLaminar flow, low Re numbersNarrow channel, Pouseille flow

Channel: 800x1500x10 µmPressure drop ~ 100 -200 Pa

Integrated temperature sensor3

12hw

Qlp⋅

⋅⋅⋅=∆

η

Page 35: Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology · Biomedical sensor technology: state ... Ralph W. Bernstein SINTEF ICT Microsystems and nanotechnology. ICT 2 MiNaLab

35ICT

ConclusionMedical sensors and BioMEMS is a rapidly growing field.Many novel sensors products are under development or already on the marketFuture medical sensors will require

Small low cost, low power sensorsRemote power generationWireless communicationNanotechnology and advanced functional and bio compatibelmaterials

The field is highly inter disiplinaryRequires arenas and projects http://biox.stanford.edu/Education

The MiNaLab facility at SINTEF enables Norwegian industry and scientists to utilize new technology for new products and reserach tools.