Quick Quick Menu
PSS MERLINTELEMETRY BOARD
Aim
To introduce personnel to the Merlin Telemetry Entry Control Board.
Objectives
By the end of this session personnelWill have sufficient knowledge and
understanding of the functions relating to the use of the Merlin Telemetry Board
PSS Merlin Telemetry Board
Integrated Digital Radio and Antenna
Fully automatic, insert the tally
Data logging (ECB stores up to 100 hours of information)
Range: 3km (line of site) / up to 53 Floors
Designed to work manually in an
emergency
Supports Rapid Deployment
PSS Merlin Telemetry Board
a. Layout , Displays & Functionsb. Display Testc. Battery & Chargingd. Setting The Timee. Signals Received from BA Set EMUf. Automatic Log ONg. Log OFFh. Forced Log OFFi. Forced Log ONj. Wearer Out of Rangek. Distress Signals (manual & automatic)l. Voluntary Withdrawal Alertm. Evacuation Signals
Quick Selection Menu
Merlin Board - Front View
Menu
Rear View,Battery & Connections
Top Section
Key Pad & Battery Display
Individual Wearer Information
Audible Alert Sounder
Remarks Panel
Service ID Number
Board Number
Brigade Name
Digital Radio Transmitter &
Receiver with Antenna
Merlin Board - Rear View
Return to FRONT VIEW
Battery 1
Gasket
Battery 2
Foam Insert
Charging Connector
External Antenna
Connector
Merlin Board – Top Section
Return to FRONT VIEW
LCD Time Clock Display
Screen
LED Display-Distress Signal
from non logged on
device –Red
LCD -Display Status Data Screen
Information Button- Scrolls Wearer Display Information
Default-Time of Whistle (TOW) Green
Evacuation Button – All –
Red LED
Wearer Information
Encoded Tally with same No. As BA set:
Key Pad
Return to TOP SECTION
Numeric key pad
Enter key
Backspace key
Use 2 & 8 to Scroll Through
Menu
LED Display-Low Battery-Amber
LED Display-Battery 1-Fail-Red
LED Display-Battery 2-Fail-Red
LED Display-Charging- Green
Wearer Information
Return to TOP SECTION
LCD Display - BA Information( use information button to scroll through wearer menu)
Single Evacuation/Acknowledgement Button
LED Display - Online Signal
LED Display - Withdraw Alert
LED Display - DSU (Manual)
Alarm
LED Display - ADSU (Motion)
Alarm
Merlin Board Display Test
Menu
In sleep mode press enter
Scroll to ‘test’
Press enter
Press all buttons (except enter) and check for audible beep
Press enter
Scroll to ‘quit’
Press enter
Battery Charging
Menu
Plug in at the back of the board
Top green battery icon illuminates constantly
Date section changes to dashes and dots
Number of dashes signifies charge level, i.e. 2 dashes, two hours etc
Flashing icon means fully charged. (14 hours from flat)
Battery lasts 8 hours
Setting The Time
From sleep mode, press enter key
Display now shows ‘quit’
Scroll up or down with 2 or 8 keys to find ‘set time’
Enter correct time, press return.
Menu
Signals Received From EMU
Menu
Cylinder pressure ( updated every 20 seconds)
Low time duration prior to TOW, (10 minutes)
Activation of Low Pressure Warning Whistle
Automatic Distress Signal Unit (ADSU) Active
Manual Distress Signal Unit (DSU) active
Voluntary withdrawal notification
Automatic Log On
Menu
Insert tally to wake up board
Board will momentarily show set No. followed by elapsed time then TOW
Online radio icon illuminates solid green to show successful link with bodyguard
Log Off
• AA – AIR SUPPLY( Close Cylinder wheel and vent Air Supply )
• BB – BODYGUARD(allow gauge to read ZERO, bodyguard will
Automatically turn off within 20 sec )
• CC – COMMS(Switch off comms ; radio & speech enhancer)
Menu
This will ensure that the set has logged off from the Merlin board
Forced Log Off
Menu
• Press enter key
• Scroll to “LOG OFF” ( scroll using 2 or 8 then )
• Enter channel No. or press appropriate channel button
• Remove tally (if inserted) and press enter key
• Scroll from N to Y to acknowledge log off
• Press enter
Forced Log On
Menu
If a tally has a faulty transponder, it may be necessary to carry out a forced log on
Faulty tally will display ‘Et’, then elapsed time
Press channel evacuation key
Enter set No. excluding prefixed zeros
Press enter
Press channel evacuation key, Red LED Flashes
Main display changes to show.
Wearer Out Of Range
Online radio icon begins to flash on Board. The blue LED on the Bodyguard will no-longer be illuminated and an X will show against the radio icon on the Bodyguard display.
TOW will remain at time shown from last communication.
Menu
Distress SignalsManual Distress Button
Automatic Distress Signal Alarm
Manual Distress Signal
Menu
Voluntary Withdrawal
Each unit has the facility to inform the ECO that the BA team are withdrawing.
Press and hold RH button, the radio icon will appear and Beep when signal is sent.
Menu
Voluntary Withdrawal (cont)
The withdrawal icon of the associated channel will begin to flash, also giving an intermittent sound.
The ECO will confirm the alarm by pressing the appropriate button, the sounder stops and the withdrawal icon stops flashing and illuminates.
Menu
Voluntary Withdrawal (cont)
On acknowledgement from ECO the Bodyguard emits a short bleep
during which time the radio icon is displayed.
When the alarm stops the Bodyguard will revert back to operational mode.
Menu
Evacuation Signals
ALL WEARERSEVACUATION BUTTON
Evacuation Signal LEDWhen acknowledged by wearer red LED
Will stop flashing & remain on
SELECTIVEEVACUATION BUTTON
On Acknowledgement Bodyguard Returns to
Operational Mode
Bodyguard Emits a Repeating Audible Bleep
On Receipt of Withdrawal SignalPress RH Button on Bodyguard
Menu
Any Questions
Menu