PUMP SMART 9 BAR - A.R.S. Elettromeccanica · UL according UL778 standard. Food approvals EPH file...
Transcript of PUMP SMART 9 BAR - A.R.S. Elettromeccanica · UL according UL778 standard. Food approvals EPH file...
A.R.S. ELETTROMECCANICA S.r.l.Regione Palice, 25 - 12064 La Morra (CN) - Italy Tel. +39 0173 500111 - Fax +39 0173 509841www.arselettromeccanica.it - [email protected]
A.R.S. ELETTROMECCANICA S.r.l.Regione Palice, 25 - 12064 La Morra (CN) - Italy Tel. +39 0173 500111 - Fax +39 0173 509841www.arselettromeccanica.it - [email protected]
PUMP MODEL: CP SMART 9 BAR
Voltage Frequency Power rating Duty Cycle Integrated
diode Approval
220 - 240 V 50 Hz 55 W 1 min ON - 1,5 min OFF at 230V 50 Hz Kema
120 V 60 Hz 60 W 1 min ON - 1,5 min OFF UL
Approvals
SafetyKEMA – DEKRA according EN 60335-1 and EN 60335-2-41 standard. For attended or unattended use.UL according UL778 standard.
Food approvals EPH file (UL provided) according NSF 169 and FDA Food code.
Electrical insulationLive parts to water – CLASS II.
Live parts to metal – CLASS I.
Functional characteristics
Working fluid Potable grade water; max temperature Tm. 35°C according to the approval.
Environmenttemperature Ambient 35°C.
Max operating noise < 46 dB (A).
Heating test Class F (155°C) according the standard EN 60335-1.
Dry workingAllowed only for the self priming phase.Self priming at 0,15 Bar in dry conditions without backpressure on the outlet side.Self priming with backpressure of 2 bar.
Thermostat Any UL, KEMA/DEKRA or VDE approved thermostat.
Durability8000 Cycles according cycle profile show.Water temperature:35°C±5°C.Back pressure: 2 Bar.
Layout drawing for dimensional purpose
Pressure-flow rate graph (Performance measured with cold coil) Terminal orientation
Available with intermediate angles.Available with 4.8 x 0.8 terminal tab.