Operating InstructionsBedienungsanleitung Manuel d‘utilisation
PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 XSolenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10
Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex
We reserve the right to make technical changes without notice.Technische Änderungen vorbehalten.Sous réserve de modifications techniques.
© Bürkert Werke GmbH & Co. KG, 2014 - 2017
Operating Instructions 1706/02_EU-EN_00810528 / Original DE
3
1 OPERATINGINSTRUCTION...................................................................41.1 Definitionofterms..................................................................... 41.2 Symbols....................................................................................... 4
2 AUTHORISEDUSE......................................................................................52.1 Explosionprotectionapproval................................................ 5
3 BASICSAFETYINSTRUCTIONS..........................................................6
4 GENERALINFORMATION........................................................................74.1 Contactaddresses................................................................... 74.2 Warranty...................................................................................... 74.3 Informationontheinternet...................................................... 7
5 PRODUCTDESCRIPTION........................................................................85.1 Design.......................................................................................... 85.2 Solenoidcoilwithcableoutlet............................................... 95.3 Solenoidcoilwithterminalbox............................................... 9
6 APPLICATIONCONDITIONSOFTHEDEVICES....................... 106.1 Specialconditions...................................................................106.2 Operatingconditions..............................................................116.3 Operatingtemperaturerange...............................................11
7 TECHNICALDATA.....................................................................................117.1 Safetyinstructions...................................................................117.2 Conformity.................................................................................117.3 Standards..................................................................................117.4 Typelabelforexplosions-riskareas....................................127.5 Electricaldataforsolenoidcoilswithcableoutlet..........14
7.6 Electricaldataforsolenoidcoilswithterminalbox..........157.7 Electricaldataforsolenoidcoilswithterminal boxandintegratedequipmentprotectionfuse.................16
8 ACCESSORIES...........................................................................................178.1 Cableglandforterminalbox.................................................178.2 Externalgroundingconnectionforterminalbox...............178.3 EquipmentprotectionfuseType1058...............................17
9 INSTALLATIONANDREMOVAL.........................................................189.1 Installation.................................................................................199.2 Electricalconnection..............................................................199.3 Removal.....................................................................................21
10 START-UP......................................................................................................21
11 MAINTENANCE,REPAIR,TROUBLESHOOTING...................... 2211.1 Maintenancework...................................................................2211.2 Repair.........................................................................................2211.3 Troubleshooting.......................................................................22
12 TRANSPORTATION,STORAGE,DISPOSAL................................22
Contents
english
AC10, II 2G/D Ex
4
Operating Instruction
1 OPERATING INSTRUCTIONTheoperatinginstructionsdescribetheentirelifecycleofthedevice.Keep these instructions in a location which is easily accessible toeveryuserandmaketheseinstructionsavailabletoeverynewownerofthedevice.
Operatinginstructioncontainimportantinformation.▶ Readtheoperatinginstructionscarefullyandfollowthesafetyinstructionsinparticular.
▶ Operatinginstructionsmustbeavailabletoeachuser.▶ Theliabilityandwarrantyforthedevicearevoidiftheoperatinginstructionsarenotfollowed.
1.1 Definition of terms
Intheseinstructions,theterm“device”alwaysreferstothesolenoidcoilAC10.
Intheseinstructions,theabbreviation“Ex”alwaysrefersto“potentiallyexplosive”.
1.2 Symbols
DANGER!
Warnsofanimmediatedanger.▶ Failuretoobservethewarningmayresultinafatalorseriousinjury.
WARNING!
Warnsofapotentiallydangeroussituation.▶ Failure toobserve thewarningmay result inserious injuriesordeath.
CAUTION!
Warnsofapossibledanger.▶ Failuretoobservethiswarningmayresultinamoderateorminorinjury.
NOTE!
Warnsofdamagetoproperty.
Importanttipsandrecommendations.
Referstoinformationintheseoperatinginstructionsorinotherdocumentation.
▶ designatesaninstructiontopreventrisks.
→ designatesaprocedurewhichyoumustcarryout.
english
AC10, II 2G/D Ex
5
Authorised use
2 AUTHORISED USE
UnauthorizeduseofthesolenoidcoilAC10maybedangeroustopeople,nearbyequipmentandtheenvironment.
ThesolenoidcoilAC10isusedtoactivatevalveswhichcontrolthegaseousorliquidmedia.
▶ AvalvecontrolledbythesolenoidcoilAC10maybeusedsolelyforthemediaspecifiedinthedatasheetandforuseinexplosiongroupIICcategory2Gand/orexplosiongroupIIICcategory2G,andtemperatureclassT4,T5orT6(refertothespecificationsonthetypelabelforexplosion-riskareas).
▶ Thesolenoidcoilmaybeusedonlyfortheapplicationsdesignatedinchapter“6Applicationconditionsofthedevices”andincon-junctionwiththird-partydevicesandcomponentsrecommendedandauthorizedbyBürkert.
▶ TheappliedprotectionclassisencapsulationEx“m”forcoilswithcableconnection.
▶ The ignitionprotectiontypefor theoptionallymountedterminalboxis“e”forgasand“t”fordust.
▶ Thefaultlessandreliableoperationofthesystemassumescor-rect transportation, correct storage and installation as well ascarefuloperationandmaintenance.Anyotheruseisregardedasunauthorized.Bürkertisnotliableforanyresultingdamage.Theuseralonebearstherisk.
▶ Onlyusethedeviceforitsintendedpurpose.
2.1 Explosion protection approval
TheexplosionprotectionapprovalisonlyvalidifyouusethemodulesandcomponentsauthorizedbyBürkert,asdescribedintheseoperatinginstructions.ThesolenoidcoilAC10maybeusedonlyincombinationwiththevalvetypesreleasedbyBürkert,otherwisetheexplosionprotectionapprovalwillbeterminated.Ifyoumakeunauthorizedchangestothesystem,themodulesorcomponents,theexplosionprotectionapprovalwillalsobevoid.EC-typeexaminationcertificateandIECExcertificatewereissuedbyPTB(PhysikalischTechnischeBunde-sanstalt)respectivelyBureauVeritas
SolenoidcoilAC10: PTB14ATEX2023X;IECExPTB14.0049X
Terminalbox: PTB15ATEX1011U;IECExPTB15.0037U
Equipmentprotectionfuse: PTBATEX2064U;IECExPTB16.0019U
Assemblyofsolenoidcoilandterminalboxandequipmentprotectionfuse: EPS16ATEX1046X;
IECExEPS16.0021X
Manufactureisauditedby: CE102PTB(PhysikalischTechnischeBundesanstalt)Bundesallee10038116Braunschweig
TheEUTypeExaminationCertificateisavailableonlineat:www.burkert.com
english
AC10, II 2G/D Ex
6
Basic safety instructions
3 BASIC SAFETY INSTRUCTIONS
Thesesafetyinstructionsdonotconsideranycontingenciesorinci-dentswhichoccurduringinstallation,operationandmaintenance.
Theoperatorisresponsibleforobservingthelocation-specificsafetyregulations,alsowithreferencetothepersonnel.
Danger–highpressure.▶ Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
Riskofelectricshock.▶ Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety regulationsforelectricalequipment!
Riskofburnsandriskoffireifusedduringlong-termoperationthroughhotdevicesurface.
Thesolenoidcoilcangetveryhotduringlong-termoperation.▶ Keepthedeviceawayfromhighlyflammablesubstancesandmediaanddonottouchthedevicewithbarehands.
Riskofexplosion.
Thesolenoidcoilandvalvebodyformaclosedsystemafterinstallation.Whenusedinexplosion-riskareas,thereisariskofexplosionifthesystemisopenedintheoperatingstate.
▶ Donotremoveoropenthesystemduringoperation.
Riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶ Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶ Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶ Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
Toavoidtheriskofexplosion,thefollowingmustbeobservedforoperationinexplosion-riskareas:
▶ Informationonthetemperatureclass,ambienttemperature,degreeofprotectionandvoltageonthetypelabelforexplosion-riskareas.
▶ Installation,operationandmaintenancemayonlybeperformedbyqualifiedspecialists.
▶ Theapplicablesafetyregulations(includingnationalregulations)aswellasgeneraltechnicalstandardsmustbeobservedduringsetupandoperation.
english
AC10, II 2G/D Ex
7
General information
▶ Repairsmayonlybeperformedbythemanufacturer.▶ The device must not be exposed to any mechanical and/orthermalloadswhichexceedthelimitsspecifiedintheoperatinginstructions.
▶ Beforeopeningtheterminalbox,disconnectthepowersupply.
Generalhazardoussituations.
Topreventinjury,ensure:▶ Securesystem/equipmentagainstunintentionalactivation.▶ Observethedirectionofflowduringinstallation.▶ After an interruption in thepower supply or pneumatic supply,ensure that theprocess is restarted in adefinedor controlledmanner.
▶ Don’tusethedeviceasaleverwhenscrewingthevalveintotheline.
4 GENERAL INFORMATION
4.1 Contact addresses
Germany
BürkertFluidControlSystemsSalesCenterChristian-Bürkert-Str.13-17D-74653IngelfingenTel.+49(0)7940-1091111Fax+49(0)7940-1091448E-mail:[email protected]
International
Contact addressescanbe foundon the finalpagesof theprintedoperatinginstructions.
AndalsoontheInternetat:www.burkert.com
4.2 Warranty
ThewarrantyisonlyvalidifthesolenoidcoilAC10isusedasintendedinaccordancewiththespecifiedapplicationconditions.
4.3 Information on the internet
OperatinginstructionsanddatasheetsforBürkertproductsareavailableonlineat:www.burkert.com
english
AC10, II 2G/D Ex
8
Product description
5 PRODUCT DESCRIPTION
5.1 Design
ComponentsofthesolenoidcoilAC10:
Bracket
Connectioncable
Componentsofthevalve:
Nut
Coreguidetube
Valvebodywithportconnection
Coilhousing
Unionnut
Fig. 1: Solenoid coil Type AC10 with cable outletValvebodywithportconnection
Coreguidetube
Nut
Componentsofthevalve:
ComponentsofthesolenoidcoilAC10withterminalbox:
Coilhousing
Bracket
Terminalbox
Screw
Circlip
Lockscrew
Washer
Ringcablelugwithsupplycable
Fig. 2: Solenoid coil Type AC10 with terminal box
english
AC10, II 2G/D Ex
9
Product description
5.2 Solenoid coil with cable outlet
ThesolenoidcoiltypeAC10isanelectromagneticvalveactuatorforvariousBürkertvalves.Asaso-calledtop-mountedcoil,itisseparated100%fromthevalve.Thevalveisaclosedsystemevenifthecoilisremoved.
Thesolenoidcoilconsistsof:
• coilwinding,
• coilhousing(madefromepoxy),
• electricalconnectioncable,
• bridgerectifier.
Alternatingcurrentordirectcurrentcontrolispossible.
ThesolenoidcoiltypeAC10isavailableinarangeofratingsdistributedacross2framesizes.Theinterfacebetweenthecoilandvalveisiden-ticalforbothframesizes.
Thecoilisplacedoverthecoreguidetubeofthevalveandattachedwithanut.Itispositivelylockedtopreventturningrelativetothevalve.
Theelectricalconnectioncableexitsperpendicular to thecoil axis.Thecableispermanentlyintegratedinthecoil.Theunionnutisnotdesignedtoberemoved.
Anelectricalcontactismadebetweenthemetalcomponentsofthevalveandthecoilattheinterfacebetweenthecoilandthevalve.Allmetalcomponentsmustbegroundedviatheprotectiveconductorintheconnectioncable.
5.3 Solenoid coil with terminal box
Thedesignofthesolenoidcoil is identicaltothedescriptionunder“5.2”, however a terminal box is also installed here (see “Fig. 2”).The terminal box is certified with the Type Examination CertificatePTB15ATEX1011UorIECExPTB15.0037U.
The cable outlet direction can be selected according to the orderrequirements. The outlet direction can be changed subsequently,howeverthisrequiresaspecialtool1).Optionallyaconnectionsetisenclosedforadditionalpotentialequalization;todothis,observethespecificationsinchapter“8.2”.
OptionallyaequipmentprotectionfuseofType1058canbeintegratedintheterminalbox.
1) To do this, please contact your local Bürkert representative.
english
AC10, II 2G/D Ex
10
Application conditions of the devices
6 APPLICATION CONDITIONS OF THE DEVICES
6.1 Special conditions
6.1.1 Avoiding build-up of electrostatic charge
WARNING!
Riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶ Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶ Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶ Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
6.1.2 Short-circuit protection
Afuse(max.3xIbinaccordancewithIEC60127-2-1)correspondingtotheratedcurrentmustbeconnectedaheadofeverysolenoidtoprotectagainstshortcircuits.
Inthecaseoftheversionwithaterminalbox,therearedeviceswhichalreadyhavethisfuseintegrated.
• Ifthemagnethasverylowratedcurrents,thefusewiththelowestcurrentvalueaccordingtothestatedIECstandardisadequate.Thisfusemustbeconnectedseparatelyupstream.
• The rated fusevoltagehas tobe thesameasorhigher than thespecifiednominalvoltageofthesolenoid.Theratedfusevalue isspecifiedonthetypelabel(seechapter“7.4”).
• Theinterruptionratingofthefuselinkmustbethesameasorhigherthanthemaximumshort-circuitcurrenttobeacceptedattheinstal-lationsite(usually1500A).
6.1.3 Block assembly
Valveblocksarepreferablymadeupsothatallunitshavethesamecoilpowerconsumption.Ifdifferentcoilpowerconsumptionvaluesareusedinasinglevalveblock,thenthetechnicaldataforthecoilwiththehighestpowerratingmustbeusedtodeterminethetemperatureclass.Inthiscasetheambienttemperaturemustbenohigherthan+40°C.
english
AC10, II 2G/D Ex
11
Technical data
6.2 Operating conditions
Thevalveprovidesacoolingfunctionforthesolenoidcoil.Thesolenoidcoilmaynotbeoperatedwithoutavalve.Thevalvebodymustmeetthefollowingrequirements:
• MaterialMetal(brass,aluminium,stainlesssteel)orpolyamide
• Minimumdimensions32mmx32mmx10mm
Alargervalvebodywithahigherheat-dissipatingcapabilitycanbeusedatanytime.
Thesolenoidcoilsdesignedforindividualinstallationmaynotbeusedforblockassembly.
Thesolenoidcoilsdesignedforblockassemblyaresuitableforbothblockassemblyandforindividualinstallation.
6.3 Operating temperature range
Observetheoperatingtemperaturerangespecifiedintheelectricaldataforalltypes.
7 TECHNICAL DATA
7.1 Safety instructions
DANGER!
Riskofexplosion.
Dangerous situations can result if the technical safety data andvaluesspecifiedonthetypelabelaren’tobservedorcannotbemet.
▶ Thedegreeofprotectionandtemperatureclassforuseofthedevicemustbeobserved.
Exceedingthevoltagespecifiedonthetypelabelcreatesasafetyhazardsinceitcanleadtooverheatingofthedevice!
▶ Don’tconnectthedevicetoahighervoltagethanthatspecifiedonthetypelabel.
7.2 Conformity
The solenoid coil Type AC10 is compliant with the EU DirectivesaccordingtotheEUDeclarationofConformity(ifapplicable).
7.3 Standards
TheappliedstandardswhichareusedtodemonstratecompliancewiththeEUDirectivesarelistedintheEUtypetestcertificateand/ortheEUDeclarationofConformity(ifapplicable).
english
AC10, II 2G/D Ex
12
Technical data
7.4 Type label for explosions-risk areas
7.4.1 Identification of the solenoid coil
Typelabelwithvalvespecifications
SolenoidcoilAC10withsamplevalveandthepositionsofthetypelabel:
TypelabelwithsolenoidcoilAC10
specifications
2023 XT4T130°C
0049 XT4T130°C
5 PX227 8 A
274833
12
34
56789
10
Fig. 3: Location and description of the explosion type label
Legend:
Position Description
1 ATEX,Certificateissuerandcertificatenumber
2 ATEX,Explosionprotectionlabelling
3 IECEx,Certificateissuerandcertificatenumber
4 IECEx,Explosionprotectionlabelling
5 TypelabelwithEx-code(last4digits)
6 Nominalvoltage,nominalpower,nominalfusevalue
7 Ambienttemperaturerange
8 Serialnumber
9 Dateofmanufacture
10 Identificationnumber
english
AC10, II 2G/D Ex
13
Technical data
7.4.2 Identification of the terminal box
NOTE!
Attachmentoftheterminalboxchangestheignitionprotectiontype.
SolenoidcoilAC10withterminalboxwithsamplevalveandthepositionsofthetypelabel:
12
34
56789
10
T4T130°C
T4T130°C
5 PX22 JA127 8 A
286863
ebtb
ebtb
EPS 16 ATEX 1046 X
IECEx EPS 16.0021 X
Fig. 4: Location and description of the explosion type labels
Legend:
Position Description
1 ATEX,Certificateissuerandcertificatenumber
2 ATEX,Explosionprotectionlabelling
3 IECEx,Certificateissuerandcertificatenumber
4 IECEx,Explosionprotectionlabelling
5 TypelabelwithEx-code(last4digits)
6 Nominalvoltage,nominalpower,nominalfusevalue
7 Ambienttemperaturerange
8 Serialnumber
9 Dateofmanufacture
10 Identificationnumber
english
AC10, II 2G/D Ex
14
Technical data
7.5 Electrical data for solenoid coils with cable outlet
7.5.1 Coils for individual installation
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX22 32 T4 -40...+60 7.0
PX23 40 T4 -40...+60 9.0
PX25 32 T6 -40...+40 3.0
PX26 40 T6 -40...+60 1.8
PX27 32 T6 -40...+50 2.25
PX29 32 T5 -40...+60 3.0
PX31 32 T4 -40...+80 3.0
7.5.2 Coils for block assembly
DANGER!
Riskofexplosionduetooverheating!▶ Don’tconnectthedevicetoahighervoltagethanthatspecifiedonthetypelabel.
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX24 32 T4 -40...+40 7.0
PX28 32 T6 -40...+40 2.25
PX30 32 T5 -40...+50 3.0
7.5.3 Technical data of the connection cable
Material2): Electronbeamcross-linkedpolyolefincopolymer
Operatingtemperaturerange2): -55...+145°Cforfixedinstallation
Minimumbendingradius2): 4xouterdiameterforfixedinstallation
Outsidediameter2): 6.2mm
Design/function: 3xstrandedcopperwire0.75mm²/LNPE
HalogenfreeinaccordancewithIEC60754-1
TestedaccordingtoDINEN13617-1foruseingasolinepumps
2) Specifications as per the manufacturer
english
AC10, II 2G/D Ex
15
Technical data
Wireassignment:
Wirecolor Assignment
green-yellow Protectiveconductor
brown Coilconnection1
blue Coilconnection2
7.6 Electrical data for solenoid coils with terminal box
7.6.1 Coils for individual installation
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX22+JA12 32 T4 -40...+60 7.0
PX23+JA12 40 T4 -40...+60 9.0
PX25+JA12 32 T6 -40...+40 3.0
PX26+JA12 40 T6 -40...+60 1.8
PX27+JA12 32 T6 -40...+50 2.25
PX29+JA12 32 T5 -40...+60 3.0
PX31+JA12 32 T4 -40...+60 3.0
7.6.2 Coils for block assembly
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX24+JA12 32 T4 -40...+40 7,0PX28+JA12 32 T6 -40...+40 2,25PX30+JA12 32 T5 -40...+50 3,0
english
AC10, II 2G/D Ex
16
Technical data
7.7 Electrical data for solenoid coils with terminal box and integrated equipment protection fuse
7.7.1 Coils for individual installation
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX22+JA11
32 T4 -40...+60 7,0
PX23+JA11
40 T4 -40...+60 9,0
PX25+JA11
32 T6 -40...+40 3,0
PX26+JA11
40 T6 -40...+60 1,8
PX27+JA11
32 T6 -40...+50 2,25
7.7.2 Coils for block assembly
Universalcurrent,availablenominalvoltagesfrom12Vto240V,frequency0to60Hz
CodeOverallwidthin
mm
Tempera-tureclass
Ambienttem-peraturerange
in°C
NominalpowerinW
PX24+JA11 32 T4 -40...+40 7,0PX28+JA11 32 T6 -40...+40 2,25
english
AC10, II 2G/D Ex
17
Accessories
8 ACCESSORIES
8.1 Cable gland for terminal box
Suitablecableglandsareavailableforuseoftheterminalbox.
Cable glands from other manufacturers may also be usediftheyaredesignedfortheinstallationlocationandcanbeinstalledcorrectly.Note that theapplication temperatureofthecableglandmustbemin.15Kabovethemax.ambienttemperature.
MaterialClamping
range[mm]
Operatingtemperature
Ordernumber
Certificatenumber
Plastic 7...13-40...+75°C
773277 3)
Brass 6...13 773278 4)
MaterialIP-Pro-tection
Dustidentification
Gasidentification
PlasticIP66 II2DExtbIIICDb II2GExeIICGb
Brass
3) PTB 13 ATEX 1015X; IECEx PTB 13.00034X4) PTB 04 ATEX 1112X; IECEx PTB 13.00027X
8.2 External grounding connection for terminal box
If solenoid coils feature a terminal box, connection terminals areenclosedfortheexternalgroundingconnection.
If thepotentialequalization isnot tobeconnectedbyapipelineorby theuseofaplastic fitting, theconnectioncanbemadevia theexternalgroundingconnection.Itsuseisthereforeoptionalandmustbeassessedbytheoperator.
Theconnectioncapacityoftheringcablelugis4-6mm2.Thecon-nectionismadeasshownin“Fig.8”.
8.3 Equipment protection fuse Type 1058
Thesereplacementfusesareavailableforsolenoidcoilswithter-minalboxandintegratedequipmentprotectionfuse.
Nominalfusevalue
Nominalfusevalue
Nominalfusevalue
Nominalfusevalue
0.050A 300254 0.250A 3002610.063A 300255 0.315A 3002620.080A 300256 0.400A 3002630.100A 300257 0.500A 3002640.125A 300258 1.000A 3002650.160A 300259 1.250A 3002660.200A 300260 1.600A 300267
english
AC10, II 2G/D Ex
18
Installation and removal
Whenselectingthenominalfusevalue,observethespecificationsonthetypelabelofthesolenoidcoil.
Thefollowingtableshowsanoverviewoftheassignmentofthenominalfusevaluestotheversionsofthesolenoidcoil.
UNom(V)5)
NominalfusevalueinA
PX22/PX24+JA11
PX23+JA11
PX25+JA11
PX26+JA11
PX27/PX28+JA11
12 1.250 1.600 0.500 0.315 0.500
24 0.500 1.000 0.200 0.160 0.250
26 0.500 1.000 0.200 0.200 0.250
48 0.315 0.400 0.125 0.063 0.125
60 0.315 0.315 0.080 0.063 0.100
100 0.125 0.160 0.050 0.050 0.063
110 0.125 0.160 0.050 0.050 0.050
115 0.125 0.160 0.050 0.050 0.050
120 0.100 0.160 0.050 0.050 0.050
125 0.100 0.080 0.050 0.050 0.050
200 0.063 0.080 0.050 0.050 0.050
230 0.063 0.063 0.050 0.050 0.050
Tab. 1: assignment table of the nominal fuse values
5) UNom : nominal voltage of the solenoid coil AC10
9 INSTALLATION AND REMOVAL
DANGER!
Danger–highpressure.▶ Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
Riskofelectricshock.▶ Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety regulationsforelectricalequipment!
Riskofburnsorriskoffireifusedduringlong-termoperationthroughhotdevicesurface.
▶ Keepthedeviceawayfromhighlyflammablesubstancesandmediaanddonottouchthedevicewithbarehands.
Riskofshort-circuitduetodamagedconnectioncable.▶ Thecoilconnectioncablehavetobefixedandprotectedagainstdamage.
Riskofexplosion.
Thesolenoidcoilandvalvebodyformaclosedsystemafterinstallation.Whenusedinexplosion-riskareas,thereisariskofexplosionifthesystemisopenedintheoperatingstate.
▶ Thesystemmustnotbedisassembledduringoperation.
english
AC10, II 2G/D Ex
19
Installation and removal
DANGER!
Riskofexplosionduetoelectrostaticdischarge.
Intheeventofasuddendischargefromelectrostaticallychargeddevicesorindividuals,thereisariskofanexplosionintheexplosion-riskarea.
▶ Takesuitablemeasurestoensurethatnoelectrostaticdischargescanbuildupintheexplosion-riskarea.
▶ Donotusethedeviceinareaswheretherearepowerfulcharge-generatingprocesses,mechanicalreamingandcuttingprocesses,thesprayingofelectrons(e.g.inthevicinityofelectrostaticcoatingequipment)aswellaspneumaticallyconveyeddust.
▶ Cleanthedevicesurfacebygentlywipingitwithadamporanti-staticclothonly.
WARNING!
Riskofinjuryfromimproperinstallation.
▶ Installationmaybecarriedoutbyauthorizedtechniciansonlyandwiththeappropriatetools.
▶ Securesystemfromunintentionalactivation.▶ Followingassembly,ensureacontrolledrestart.
9.1 Installation
Detailed installation instructions canbe found in theoper-ating instructions of the respective valve and/or online at:www.burkert.com
9.2 Electrical connection
DANGER!
Riskofelectricshock.▶ Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation.
▶ Observeapplicable accidentprevention andsafety regulationsforelectricalequipment.
Thereisariskofelectricshockifthereisnoelectricalcontactbetweenthemetalpartsofthevalveandtheprotectiveconductorofthecoil.
▶ Alwaysconnecttheprotectiveconductor.▶ Testforcontinuitybetweentheprotectiveconductorofthecoilandthecoreguidetubeofthevalve.
Ifsolenoidcoilsfeatureaterminalbox,alsoobservethefollowing:
▶ Insertpermanentlyinstalledcablesandlinesonly.▶ Useasuitablecableand lineentry(seechapter“8”).Observespecificationsintheenclosedoperatinginstructions.
▶ Intheterminalboxconnectonlywireswhichhavearatedconnec-tionbetween0.75mm2and1.5mm2.
▶ Tightenterminalscrewsto1.2Nm.▶ Lockhousingcoverproperly.Tightenlockscrewto2Nm.▶ Checkcontinuityoftheprotectiveconductorconnection.▶ Beforeopeningthehousingcover,disconnectthepowersupply.▶ Connectmaximumtwoconductorstoeachterminalpoint.
english
AC10, II 2G/D Ex
20
Installation and removal
▶ Temperatureresistanceofthecablemustbemin.15Kabovethemax.ambienttemperature.
▶ Whenusingflexiblelines,usewireendferrules.
Terminalbox:▶ Theconnectionterminalsfortheexternalearthconnection,whicharepackedfordeliveryinabagandbondedtothehousingcover,mustberemovedduringinstallationofthedevice.
9.2.1 Solenoid coils with cable outlet
TheconnectioncableisencapsulatedwiththesolenoidcoilTypeAC10andcannotberemoved.Observetheindicatedvoltageaccordingtothetypelabel.
9.2.2 Solenoid coils with terminal box
green-yellow
blue
brown
PositionPinassignmentof
thesupplyline
Protectiveconductor
1Neutralconductor/
negativepole(-)
2Phase/positivepole
(+)
Fig. 5: Terminal box
grün-gelb
blau
braun
PositionPinassignmentofthe
supplyline
Protectiveconductor
1Neutralconductor/
negativepole(-)
3 Phase/positivepole(+)
Fig. 6: Terminal box with integrated equipment protection fuse
Screw
Circlip
Clampingbracket
Connectionline
Washer
Fig. 7: Protective conductor connection
english
AC10, II 2G/D Ex
21
Installation and removal
Screw
Circlip
Washer
Washer
Ringcablelugwithsupplyline
Fig. 8: Connection of external potential equalization
9.3 Removal
DANGER!
Danger–highpressure.▶ Beforelooseningthelinesandvalves,turnoffthepressureandventthelines.
Riskofelectricshock.▶ Beforereachingintothedevice,switchoffthepowersupplyandsecuretopreventreactivation!
▶ Observeapplicable accidentprevention andsafety regulationsforelectricalequipment!
WARNING!
Riskofinjuryfromimproperremoval.
▶ Removalmaybecarriedoutbyauthorizedtechniciansonlyandwiththeappropriatetools.
Riskofinjuryduetomediaescapingfromleakyconnections.▶ Sealtheconnectionlinescarefully.
→ Separatetheelectricalconnections.
→ Separatethevalvebodyfromthepipeline.
NOTE!
Malfunctionsduetodirt!• RemovetheoldPTFEtapefromtheconnectionsduringre-installs.
Taperesiduemustnotgetintothepipeline.
10 START-UPWARNING!
Riskofinjuryfromimproperoperation.Improperoperationmayresultininjuriesaswellasdamagetothedeviceandtheareaaroundit.
▶ Beforestart-up,ensurethattheoperatingpersonnelarefamiliarwith and completely understand the contents of the operatinginstructions.
▶ Observethesafetyinstructionsandintendeduse.▶ Onlyadequatelytrainedpersonnelmaystartuptheequipmentorthedevice.
english
AC10, II 2G/D Ex
22
Installation and removal
Beforestartingupthedevice,ensurethat:
→ thedevicehasbeeninstalledcorrectly,
→ theconnectionhasbeenmadeproperly,
→ thedeviceisnotdamaged.
11 MAINTENANCE, REPAIR, TROUBLESHOOTING
11.1 Maintenance work
ThesolenoidcoilAC10aremaintenance-freewhenoperatedundertheconditionsdescribedinthismanual.
11.2 Repair
DANGER!
Dangerduetoimproperrepairs.
Thesafetyand functionalityof theAC10coil andcorrespondingsolenoidvalvefollowingarepairareonlygiveniftherepairworkwasperformedbythemanufacturer.
▶ Onlyhavethedevicerepairedbythemanufacturer.
11.3 Troubleshooting
Ifmalfunctionsoccur,ensurethat:
→ thedevicehasbeeninstalledcorrectly,
→ theconnectionhasbeenmadeproperly,
→ thedeviceisnotdamaged,
→ thevoltageandpressurehavebeenswitchedon,
→ thepipelinesarefree.
12 TRANSPORTATION, STORAGE, DISPOSAL
NOTE!
Transportdamages!
Inadequatelyprotectedequipmentmaybedamagedduringtransport.
• Duringtransportationprotectthedeviceagainstwetanddirtinshock-resistantpackaging.
• Avoidexceedingordroppingbelowtheallowablestoragetemperature.
Incorrectstoragemaydamagethedevice.
• Storethedeviceinadryanddust-freelocation!
• Storagetemperature:-40...+55°C.
Damagetotheenvironmentcausedbydevicecomponentscontaminatedwithmedia.
• Ensurethedeviceandpackagingaredisposedofinanenviron-mentallysoundmanner.
• Observeapplicableregulationsrelatingtorefusedisposalandtheenvironment.
english