Laboratoire d’Ingénierie des Systèmes de Versailles Master 2 Capteurs, Systèmes Electroniques et Robotiques Project CREATING A LABVIEW INTERFACE FOR MEASURING THE POSTION AND ORIENTATION OF THE FOOT OF HUMANOID ROBOT BASED ON FOUR INFRARED SENSORS by DUONG Tan Quang Supervisors Mrs. Nelly NADJAR GAUTHIER Mr. Olivier BRUNEAU February, 2014

Transcript of Project of Labview+Humanoid Robot_DUONG Tan Quang

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    1

    Laboratoire dIngnierie des Systmes de Versailles

    Master 2 Capteurs, Systmes Electroniques et Robotiques

    Project CREATING A LABVIEW INTERFACE FOR MEASURING THE POSTION AND ORIENTATION OF THE FOOT OF HUMANOID

    ROBOT BASED ON FOUR INFRARED SENSORS by

    DUONG Tan Quang

    Supervisors

    Mrs. Nelly NADJAR GAUTHIER Mr. Olivier BRUNEAU

    February, 2014

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    2

    Contents Acknowledgement 1. Introduction. 4

    1.1. Overview............................................................................................... 4 1.2. Sharp IR sensor............. 4 1.3. Labview 4 1.4. Problem statement. 4

    2. Analytical equation of the position and orientation 5 2.1. Establish the equation 5 2.2. Validation.. 8

    3. Measurement & Labview User Interface. 10 3.1. Measurement 10 3.2. Programming the interface and validation.. 13

    4. Analysis.. 16 4.1. Choosing the cut-off frequency....16 4.2. The quality of filtering..... 17 4.3. Comparing the accuracy at different distances 18

    5. Conclusion & Future Developments 19 Bibliography

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    3

    Acknowledgement

    First, I would like to thank my supervisors Mrs. Nelly NADJAR GAUTHIER and Mr. Olivier BRUNEAU. Thank you for give me the great knowledge of humanoid robots locomotion, robot dynamic, measurement with Labview, and DSP. Thank you for give me the precious advices and ideas when I met the problems in this project. I would like to thank Mr. Eric MONACELLI. Thank you for give me a chance to do this project and provide me the great instructions for the presentations. From the LISV, I would like to thank Mr. Barrois Olivier. Thank you for support me the measurement devices and give me the instructions about the devices. I would like to thank my friends in the class of CSER. Thank you Sun, Linda, Massi, who give me a hand in the measurement. Thank Zamourri Meher, who gives me the French conversations every day although my French skill is not good. Thank you so much! Without the help from all of you, I could not finish this project at all.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    4

    1. Introduction 1.1. Overview The walking control is still one of the hardest tasks in designing a humanoid robot. To control the movement of the foot exactly, it is necessary to know the position and orientation of the foot in the reference frame. In the real environment, the robot foot may confront with the change of terrain or with the obstacles. It is therefore important to determine the distance between the foot and the terrain or the obstacle, in order to adjust the controlling strategy appropriately and timely.

    1.2. Sharp IR sensor[1] The Sharp IR sensor works by the process of triangulation. A pulse of light (wavelength range of 850nm +/-70nm) is emitted and then reflected back (or not reflected at all). When the light returns it comes back at an angle that is dependent on the distance of the reflecting object. Triangulation works by detecting this reflected beam angle. By knowing the angle, distance can then be determined.

    Figure 1.1: Introduction of Sharp IR sensor

    1.3. Labview[2] NI LabVIEW (Laboratory Virtual Instrument Engineering Workbench) is a graphical programming language designed for engineers and scientists to develop test, control, and measurement applications. The intuitive nature of LabVIEW graphical programming makes it easy for educators and researchers to incorporate the software in a range of courses and applications. With LabVIEW, educators and researchers can use a graphical system design approach to design, prototype, and deploy embedded systems. It combines the power of graphical programming with hardware to dramatically simplify and accelerate the development of designs

    1.4. Problem statement The problem of the project is to calculate the distance between any points on the robots foot and the ground or the obstacle, as well as to determine the angle of

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    5

    pitch and the angle of roll of the foot. The measuring results should be shown in a computer interface. The measurement is based on the four infrared sensors GP2D120, which are attached in the four corners of the robots foot. The sensor is integrated with signal processing and analog voltage output, which helps to measure the distance from 4 cm to 30 cm. The interface will be based on the Labview, which is software of National Instrument Company, along with the diver card NI PCI 6221 and a testing box of BNC 2120. All of the results should be validated, firstly in the static state and later on the dynamic state of the humanoid robots foot.

    2. Analytical equation of position and orientation 2.1. Establish the equation

    Figure 2.1: A model of robots foot in the reference frame ()

    A model of robots foot in the reference frame (OXYZ) is illustrated in the figure 2.1. The foot is shown as a rectangle ABCD, in which the four sensors (14) are attached at the four corners (AD). The local frame (OXYZ) is placed at the A point. The projects objective is to calculate the roll angle , as well as the pitch angle and the distance between any M point on the foot and the ground, in other words, that is in the reference frame (OXYZ).

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    6

    The equations will be built based on an analytical model in the figure 2.2, as follows.

    Figure 2.2: An analytical model for calculating

    There are some importance remarks from the above model: - The light line from the sensor is perpendicular to the foot plane. It means that (d d ) (2) and (d d) (3) - The first rotation about the Y axis is considered as the projection of AD and

    BC on the ground, taking the plane 1 to the plane 2 - The second rotation about the X axis is considered as the projection of AB and

    CD on the ground, taking the plane 2 to the plane 3 - The value of (d d) is well calculated by the sensor and the Labview

    software. Besides, the size of the robot foot is also well known. It is now easy to find out the value of , and Z :

    = arctan

    ; = arctan

    (1)

    d = d cos; d = d cos; d = d cos; d = d cos; (2) = arctan

    ; = arctan

    (3)

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    7

    (2) (3) = arctan

    cos ; = arctan

    cos (4) In this case, the pitch angle is negative. Therefore, in order to not lose the general property; the equation of (4) is rewritten as follows:

    = arctan

    cos ; = arctan

    cos (5) The value of Z is simply determined by the following equation: Z = d cos (6) (2) (6) Z = d cos cos (7)

    The value of is now calculated by the following analysis: The movement of the robots foot is considered as first one translation from the reference frame (OXYZ) to the frame (OXYZ), then one rotation about the Y axis with the pitch angle and finally one rotation about the X axis with the roll angle . The homogenous transformation matrices of these one translation and two rotations are, respectively T, T, and T,:

    T =1 0 0 X0 1 0 Y0 0 1 Z0 0 0 1

    , T, = cos 0 sin 00 1 0 0 sin 0 cos 00 0 0 1 , T, = 1 0 0 00 cos sin 00 sin cos 00 0 0 1

    In the reference frameR, Z Z| . From (7): Z| = d cos cos. While the coordinate of any point M on the robots foot in the frame and are, respectively P| = [X Y 0 1]and P| = [X Y Z 1] Therefore, the P| is calculated by the following formula: P| = T T , T , P|

    XYZ1 = 1 0 0 X0 1 0 Y0 0 1 d cos cos0 0 0 1

    cos 0 sin 00 1 0 0 sin 0 cos 00 0 0 1

    1 0 0 00 cos sin 00 sin cos 00 0 0 1 XY01

    XYZ1 = 1 0 0 X0 1 0 Y0 0 1 d cos cos0 0 0 1

    cos sin sin sin cos 00 cos sin 0 sin cos sin cos cos 00 0 0 1

    XY01 = cos cos sin + cos sin (8)

    From the equations of (1), (5) and (8), the values of , are simply determined.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    8

    Figure 2.3: The model with the negative pitch angle and the positive roll angle

    2.2. Validation a. Validation based on the trigonometric formula Considering the example in the figure 2.3. In the view of algebra: >0, >0, O1XM>0, O1YM>0, Z1M=0

    We have:

    = + (9) = cos (10) = sin (11) = (12) = cos cos (13) = sin (14)

    (9 14) = cos cos sin + cos sin (15) The equation (15) is identical to the equation (8)

    b. Validation based on the software of Cabri Geometry[*]

    1st case: The angle of pitch is negative ( < 0) and the angle of roll is positive ( > 0)

    Figure 2.4: The first model of the robots foot with > 0 and < 0

    [*]Cabri Geometry is commercial interactive geometry software produced by the French company Cabrilog for teaching and learning geometry and trigonometry. In this project, I use its demo version

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    9

    Calculate , Uncertainty() % = -0.0389 = 0,02258

    = cos cos sin + sin cos 0,040339 = | | = 0,00002 0,052% = 29,9490 = | | = 0.077 0,26% = 29,8730 = | | = 0.001 0,003%

    = cos -22,9490 = | | = 0,02 0,08% = cos -22,9930 = | | = 0,024 0,1% = cos -22,9650 = | | = 0,0004 0,001% = cos -23,0080 = | | = 0,039 0,17%

    2nd case: The angle of pitch is positive ( > 0) and the angle of roll is negative ( < 0)

    Figure 2.5: A model of the robots foot with < 0 and > 0

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    10

    Calculate , Uncertainty() % = -0,03530 = 0,02188

    = cos cos sin+ sin cos 0,030892 = | | = 0,000008 0,025% = -29,6800 = | | = 0.006 0.02% = -29,6990 = | | = 0.013 0,04%

    = cos 18,4680 = | | = 0,011 0,06% = cos 18,4560 = | | = 0,001 0,005% = cos 18,4650 = | | = 0,008 0,04% = cos 18,4530 = | | = 0,004 0,02%

    3. Measurement and Labview User Interface

    3.1. Measurement[4] a. Wiring Instruction The wiring of the sensor is straight forward because the sensor already has the wire adapter to plug straight into the screw terminals of the myDAQ. In order to power the sensor, it needs to be connected to a 4.5 to 5.5 VDC source via the red wire (Vcc). The myDAQ has a 5V output connection that can supply up to 500mA of current. The data sheet of the sensor says that the Sharp Infrared Proximity Sensor has a typical 33mA current draw from the power source, which is well below the limit of the myDAQ. Once the red power wire is connected the black wire (GND) needs to be connected to the ground of the myDAQ (this makes sure that the sensor and the myDAQ both have the same reference point). In this case we connected the black wire to AGND. The ground also needs to be connected to AI0-.

    b. Measuring strategy There are 4 steps of the measurement based on Labview:

    1. Gather the raw data in the form of voltage from the sensor. 2. Filter and average the data so that we can reject some noise. 3. Interpolate the data to convert it into distance. 4. Applying the analytical equations to determine the desired values.

    In order to receive data at a consistent rate, use the continuous acquisition mode to get a set amount of data utilizing the myDAQ onboard timing engine. The timing

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    11

    engine will ensure that the time between samples is consistent for the duration of the program. Even though the data is gathered, it will be slightly noisy, and this is due to external noise that might be found on the wires or even from extra light being detected by the sensor. Even though the sensor does have signal conditioning to reduce noise, it is not fully immune to noise. In order to filter out the noise, a low pass filter should be used to remove extraneous spikes. The sensor actually sends back data in "time windows" which can be seen on the graph as steps of voltage. In order to keep the timing and coding simple, the next task is to average the sample set instead of trying to match the timing of the myDAQ's sample set to the sample set of the sensor. After filtering the data and averaging the sample set into a single voltage, this value is in volts and not centimeters. In order to convert this data to centimeters, it is necessary to find a way to map this value to a non-linear curve as seen in figure 3.1 below and in the data sheet.

    Figure 3.1: Distance Vs Voltage graph (From Sensors Datasheet)

    The non linearity is a problem since we cannot use a line approximation, but we can use the spline interpolation functions found in LabVIEW to curve fit the above figure to the data. In order to use interpolation, there has to be a set of known values. By using estimated points from the graph in figure 3.1, we can estimate a set of data that the spline interpolation can use as a guide to determine the centimeter or voltage value. In this project, the following table is considered.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    12

    Table 1: Approximate Centimeter to Volt Pairs

    From the table 1, the graph of distance vs voltage and the interpolating equation can also be built again by using Excel, as can be seen in the figure 3.2.

    Figure 3.2: Distance Vs Voltage graph and the interpolating equation built by Excel

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    13

    3.2. Programming the interface and validation[5] There are two main blocks in programming the interface. The first one is to gather raw signal from sensor, process the signal, as well as interpolate the data to convert it into distance. The later is for calculate the desired values. The processing block is programmed as the figure 3.3:

    Figure 3.3: The processing block

    The validation for this block is checked by testing the result from one sensor, as can be seen in the figure 3.4.

    Figure 3.4: The front panel of the signal processing block

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    14

    The calculating block is programmed as follows:

    Figure 3.5: The calculating block

    The block in figure 3.5 is built to calculate the equation of (1), (5) and (8). The validation is checked as follows.

    Figure 3.6: Validation for the first case of 2.2.b

    The result in the figure 3.6 is the same as the result in the first case of 2.2.b

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    15

    Figure 3.7: Validation for the second case of 2.2.b

    The result in the figure 3.7 is the same as the result in the second case of 2.2.b When the two blocks are validated, signals from the four sensors will be processed at the same time and the final interface is shown like the figure 3.8.

    Figure 3.8: The Labview interface for the measurement

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    16

    4. Analysis 4.1. Choosing the cut-off frequency[6] These errors associated with the measurement are typically referred to as noise and are an undesirable portion of any kinematic waveform. Noise is traditionally lower in amplitude and associated with a different frequency range than that of the true signal (Jackson, 1979) and can typically be removed using a low-pass filter; the objective of any filtering technique is not only to attenuate noise but also to leave the true signal unaffected (Winter, 1990). When using a low-pass filter the cut-off frequency is selected so that the lower frequencies remain yet the higher frequencies are attenuated. As the cut-off frequency increases, the influence of the filter on the data is reduced and the data will be similar to the raw signal, including some of the high frequency noise (Robertson and Dowling, 2003). Determining the most appropriate cut-off frequency is essential and necessitates knowledge of the signals characteristics. A number of algorithms exists which are designed to define an objective criterion for the determination of an appropriate cut-off frequency (Jackson, 1979). In this project, the algorithm chosen is about a residual analysis (Wells and Winter, 1980). The term residual refers to the signal content that remains when then filtered data is subtracted from the raw data (Robertson, 2005).

    Figure 4.1: Cut-off frequency vs residual voltage plot

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    17

    The figure 4.1 shows the plot of cut-off frequency vs residual voltage, in which a range of test cut-off frequencies is chosen by, for example, 0.001*fs, 0.002*fs,.. 0.01*fs,... 0.48*fs. (Remember that 0.5*fs= the Nyquist frequency.). The residual amplitude is an estimate of how different the filtered voltage is from the unfiltered voltage, for the cut-off frequency chosen. It can be concluded that the residual amplitude will always be greater at a lower cut-off frequency, since a lower cut-off frequency changes the raw data more than a higher cut-off frequency The geometric line represents the best estimate of the noise residual and is positioned so that it follows the linear portion of the residual plot and intercepts the axis at (0 Hz). The decision regarding the cut-off requires a compromise between the extent of signal attenuation and the amount of noise allowed to pass through. Typically a horizontal line is projected from to intersect the residual plot at and the cut-off is selected at , which has the frequency of 138 Hz. 4.2. The quality of filtering

    Figure 4.2: Comparing the raw signal and filtered signal

    The low pass filter is chosen with the following specifications: - Sample number: 100 - Sampling rate: 1000 - Cut-off frequency: 138 Hz - ADC resolution: 16 bits - Infinite impulse response filter: Topology Butterworth, Order-2 As the result in the figure 4.2, the responding time of the filter is 0.005s or 5ms. The signal has some peaks, which is caused by multiple connection terminals. To evaluate the filter, it is also necessary to consider the voltage attenuation, which is the result from the communication between devices and the effect of filtering. As can be seen in the figure 4.3, the voltage attenuation is about ..

    . 100% ,% and the distance error is ... 100% .%.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    18

    Figure 4.3: The voltage attenuation in measuring

    4.3. Comparing the accuracy at different distances . . . . . . . 5.129 8.225 11.801 13.285 17.903 24.411 28.866

    5.099 8300 11.855 13.345 18.893 24.136 32.405 5.081 8.200 11.909 13.429 19.545 23.728 28.494 5.110 8.400 12.273 13.024 18.596 22.872 30.019

    5.100 8.159 12.036 13.225 19.456 22.651 20.954 5.148 8.221 11.895 13.498 21.309 25.456 29.868 5.134 8.380 11.795 13.512 19.404 20.934 27.282

    5.032 8.300 12.184 13.670 18.460 23.881 29.858 5.135 8.328 11.719 13.089 19.299 22.177 29.538 5.156 8.380 11.955 13.345 19.221 23.810 26.190 = .% = .% = .% = .% = .% = .% = .%

    Table 2: Comparing the accuracy in measuring at different distances

    The table 2 provides some importance remarks in measuring with the Sharp infrared sensors: - The greater distance is, the less accurate the measuring is. - From 4 to 30 cm, the relative error in measuring increases from about 0.24% to

    about 3.08%. The error is acceptable.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    19

    5. Conclusion & Future Developments 5.1. Conclusion The project is successful in building a model for calculating the analytical equations, as well as creating a Labview interface, that is easy to manage for users. Besides, all of the results are validated well in the different ways. Infrared sensors emit infrared light, and therefore the sensors cannot work accurately outside or even inside, if there is direct or indirect sunlight. However, Sharp IR sensors can work pretty accurately in ambient light. Therefore, it is a good choice for measuring the distance in the project of humanoid robot.

    5.2. Future Developments In the future research, the accuracy should be checked at the different surfaces and different light conditions. Besides, this project has not also evaluated the quality of the chosen filter in the case of dynamic model yet. To do so, from the equations (1), (5) and (8), it is necessary to solve the inverse geometric model. It means that the correlation functions of , and 0 should be found first in the real walking cycle. Then, from the above equations, find out the simulated function of d, d, d, d under the following form: d = A sin(t + ) + B = A sin

    t + + B, in which is

    the phase and T is the period. The problem is now that changing the period T as so fast enough as the desired humanoid robot model and adjusting the specifications of the chosen filter in order to measure the data exactly and timely during the walking cycle.

  • DUONG Tan Quang Master 2 CSER UVSQ 28/02/2014

    20

    Bibliography

    [1] http://www.societyofrobots.com/sensors_sharpirrange.shtml [2] http://www.ni.com/labview/ [3] The course Bio-Mechanics and Locomotion Mr. Olivier Bruneau, Universit de Versailles Saint Quentin [4] http://www.ni.com/example/31470/en/#toc1 [5] The course Travaux pratiques Decouverte de Labview Mrs. Nelly Gauthier, Universit de Versailles Saint Quentin [6] Digital Filtering of Three-Dimensional Lower Extremity Kinematics: an Assessment, Jonathan Sinclair1, Paul John Taylor, Sarah Jane Hobbs, Journal of Human Kinetics volume 39/2013, 25-36 DOI: 10.2478/hukin-2013-0065 ,.Section I Kinesiology