Product Selection - Evergreen Energy...

10
HiBrite Industrial Lighting • Sioux Falls, SD • 1-605-339-1111 • FAX: 1-605-332-7178 • www.hibritelighting.com Product Selection Product Selection HF8-2 Two Lamp T-8 Open Fixture 70 Watts Available in 120, 277, 347 or Universal 120-277 Volt HF8-4 Four Lamp T-8 Open Fixture 140 Watts Available in 120, 277, 347 or Universal 120-277 Volt HF8-6 Six Lamp T-8 Open Fixture 210 Watts Available in 120, 277, 347 or Universal 120-277 Volt HF8W S -12 Twelve Lamp T-8 Fixture 420 Watts Available in 120, 277, 347 or Universal 120-277 Volt EF8-4 Four Lamp T-8 Enclosed Fixture 140 Watts Available in 120, 277, 347 or Universal 120-277 Volt EF8-6 Six Lamp T-8 Enclosed Fixture 210 Watts Available in 120, 277, 347 or Universal 120-277 Volt EF8W S -12 Twelve Lamp T-8 Fixture 420 Watts Available in 120, 277, 347 or Universal 120-277 Volt Plugs must be specified upon ordering. Non-standard cord lengths are available. Some styles also available in T-5 lamps. Specifications and photometric data available on our website in printable format. Distributed by: TWO SIX LAMPS CONNECTED WITH A SIX-FOOT WHIP. TWO SIX LAMPS CONNECTED WITH A SIX-FOOT WHIP.

Transcript of Product Selection - Evergreen Energy...

HiBrite Industrial Lighting • Sioux Falls, SD • 1-605-339-1111 • FAX: 1-605-332-7178 • www.hibritelighting.com

Product SelectionProduct Selection

HF8-2 Two Lamp T-8 Open Fixture70 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

HF8-4 Four Lamp T-8 Open Fixture140 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

HF8-6 Six Lamp T-8 Open Fixture210 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

HF8WS-12 Twelve Lamp T-8 Fixture420 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

EF8-4 Four Lamp T-8 Enclosed Fixture140 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

EF8-6 Six Lamp T-8 Enclosed Fixture210 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

EF8WS-12 Twelve Lamp T-8 Fixture420 WattsAvailable in 120, 277, 347 orUniversal 120-277 Volt

Plugs must be specified upon ordering. Non-standard cord lengths are available.Some styles also available in T-5 lamps.

Specifications and photometric data available on our website in printable format.

Distributed by:

TWO SIX LAMPS CONNECTEDWITH A SIX-FOOT WHIP.

TWO SIX LAMPS CONNECTEDWITH A SIX-FOOT WHIP.

Features & BenefitsFeatures & BenefitsThe New StandardSaves up to 70% on your electricity for lighting

The New StandardSaves up to 70% on your electricity for lighting

HiBrite Industrial Lighting • Sioux Falls, SD • 1-605-339-1111 • FAX: 1-605-332-7178 • www.hibritelighting.com HiBrite Industrial Lighting • Sioux Falls, SD • 1-605-339-1111 • FAX: 1-605-332-7178 • www.hibritelighting.com

OTHER BENEFITS INCLUDE:

OPEN AREA - Maintained Horizontal Footcandles Spacing 20'On Center. Mounting Height 24'

12' WIDE AISLE - Maintained Horizontal Footcandles Spacing 20”On Center. Mounting Height 24'

INSTANT-ON: Ideal for use with occupancy sensors.Nothing saves energy like lights out! In the event of apower interruption, lights are back on the instant thepower is restored.

EMERGENCY LIGHTING: Handle all emergencylighting needs with the HiBrite luminaire, eliminating theneed for a secondary lighting system.

WHITE LIGHT: 85+ CRI versus metal halide’s 65 withminimal color shift. Unlike HID, fluorescent lampsmaintain consistent color throughout their life.

SHALLOW FIXTURE DEPTH: Depth of less than 4"allows fixture to be mounted near the ceiling formaximum space utilization and reduces damageincurred from material handling equipment.

MAINTENANCE: Virtually maintenance free.

Two to six lamp T8 and four lamp T5 allows HiBrite to beused in many different applications at a variety ofheights. Customize the HiBrite using the wide variety ofoptions and accessories to perfectly fit your specificneeds. Quick and easy installation, superior opticalperformance and many years of trouble free operationare a few of the many benefits of the HiBrite Industriallight.

Call 1-605-339-1111 and see how HiBrite Industrial HighBay lighting can save you energy and improve yourlighting.

FIXTURE HP8-6 6 400 WATTCOMPARISON LAMP HID

Initial Lumens 19,000 36,000

Lamp LumenDepreciation 5% 30-50%

Avg. FixtureEfficiency 98% 75%

MaintainedLumens 18,200 18,900

Energy Consumed 210 Watts 460 Watts

MaintainedLumens/Watt 84 40.6

HERE IS HOW IT WORKS:

Pulse 350HF8-6 Start HID 400

Footcandles Producedwith New Lamps 58 25 28

Footcandles after10,000 hours 52 16 20

Footcandles after16,000 hours 50 14 17

Energy Consumed 210 Watts 400 Watts 460 Watts

• Increases usable light levels by at least 100%.• Instant on, no re-strike time versus 5-7 minute restrike

for HID’s.• Less than a 7% light loss over the lifetime of the bulb

versus 40%+ light loss in the first year with HID’s.• 36,000 to 38,000 hour lamp life - Miro4® reflector, 95%

reflective surface.

• Increases productivity while creating a safer workenvironment.

• Reduces labor costs - Color Rendering Index 85+versus 65 for HID’s.

• Virtually no maintenance costs - Pays for itself quickly.

HOUSING - 22GA Galvanized steel body, socketbrackets, end plates and lens brackets.

REFLECTOR - .020" Enhanced (Miro4®) Aluminum

OPTIONAL LENS - Accepts up to .125" Acrylic,Polycarbonate or Tempered Glass Clear Lens

OPTIONAL WIRE GUARD - Accepts heavy gauge 2" x2" spacing wire guard using nylon or galvanizedmounting clips.

MOUNTING - Mounts using standard “jack chain”S Hook mounting hardware.

ELECTRICAL - 120, 277, 347 and multi-volt electronicballast available.

• Optional 2/4 or 3/3 lamp universal voltage electronic ballasts.

• Optional A/B Switching.• Power cord is standard 8' SJTW 3W/18GA cord with strain relief.• Bi-pin Instant Start Sockets are ratcheted to

secure lamp in position

HARDWARE is Aluminum or Galvanized.

FIXTURE is UL Listed for dry or damp locations in US andCanada.

4' 4' 4' 4' 4'HF8-2 HF8-4 HF8-6 EF8-4 EF8-6

12' 24 44 64 42 62

15' 22 42 62 40 60

18' 21 40 60 38 88

20' 20 38 58 36 56

22' — 36 56 34 54

25' — — 61 — 48

30' — — 47 — 44

35' — — 37 — 42

40' — — 35 — 39

60' — — 29 — 28

4' 4' 4' 4' 4'HF8-2 HF8-4 HF8-6 EF8-4 EF8-6

12' 14 28 41 26 39

15' 13 26 37 24 35

18' 12 24 35 22 33

20' 9 22 33 20 32

22' — 19 30 17 30

25' — 17 27 15 24

30' — — 23 — 20

35' — — 22 — 18

40' — — 20 — 15

60' — — 17 — 13

SPACING = 20' On Center MOUNTING HEIGHT = 24'

Now you can replace your old out-dated fixtures one-for-one with the HiBrite HF8-6 and improve your lightlevels with half the energy.

Visit our website at www.hibritelighting.com and click onthe HiBrite Savings calculator for and estimated savingsof your lighting needs or contact us awww.hibritelighting.com and click on find a dealer tofind our authorized dealer in your area.

SEE WHAT YOU CAN SAVE!!

Specifications & OptionsSpecifications & Options

THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.

CHECKED BY

TESTED BY HERSCHEL SCHRECK

MIKE GRATHER

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09334 DATE: 10-26-2005PREPARED FOR: ENERCON/HIBRITE INTERNATIONALCATALOG NUMBER: HF8-2LUMINAIRE: FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM REFLECTOR,

NO ENCLOSURE.LAMPS: TWO 32 WATT T8 LINEAR FLUORESCENT LAMPS RATED AT 2950 LUMENS

EACH.LAMP CATALOG NUMBER: PHILIPS F32T8/TL850/PLUS/ALTOBALLAST: ONE GE GE-232-MAX-N/ULTRAMOUNTING: PENDANT

LUMEN TO CANDELA RATIO USED = 9.18TOTAL INPUT WATTS = 56.5 AT 120.0 VOLTSTHE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS.

CANDELA DISTRIBUTION FLUX0.0 22.5 45.0 67.5 90.0

0 2543 2543 2543 2543 25435 2521 2528 2528 2503 2499 23815 2432 2386 2311 2235 2201 65125 2247 2136 1938 1764 1719 90235 1982 1793 1496 1370 1312 98645 1659 1339 1094 956 948 90655 1272 916 729 731 742 76165 850 512 519 624 658 59875 420 274 386 418 440 40085 57 110 147 150 153 14090 0 6 13 14 20

ZONAL LUMEN SUMMARYZONE LUMENS %LAMP %FIXT0- 30 1790 30.3 32.10- 40 2777 47.1 49.70- 60 4444 75.3 79.60- 90 5582 94.6 100.090-180 0 0.0 0.00-180 5582 94.6 100.0

TOTAL LUMINAIRE EFFICIENCY: 94.6%CIE TYPE: DIRECTPLANE: 0-DEG 90-DEGSPACING CRITERIA: 1.2 0.9LUMINOUS LENGTH: 48.250 7.125

LUMINANCE IN CANDELA PER SQUARE METERANGLE AVERAGE AVERAGE AVERAGEIN DEG 0-DEG 45-DEG 90-DEG

0 11465. 11465. 11465.45 10577. 6975. 6044.55 9998. 5730. 5832.65 9068. 5537. 7019.75 7316. 6724. 7664.85 2948. 7604. 7914.

540

1080

1620

2160

2700

0 15 30

45

60

75

90

105120135150165180

0 Deg. Plane 90 Deg. Plane

3.500"

7.125"

8.750"

0.6

25

"

1.5

00

"

2.2

50

"

#09334

THIS TEST WAS CONDUCTED USING RELATIVE PHOTOMETRY TECHNIQUES ACCORDING TO STANDARD IESNA PROCEDURES. THE

USER MUST THEREFORE USE CAUTION IN THE FOLLOWING SITUATIONS: 1) THIS TEST WAS PERFORMED USING A

SPECIFIC BALLAST/LAMP COMBINATION. EXTRAPOLATION OF THESE DATA FOR OTHER BALLAST/LAMP COMBINATIONS MAY

PRODUCE ERRONEOUS RESULTS. 2) ACCORDING TO IESNA PROCEDURES, THE BALLAST(S) AND LAMP(S) ARE PRESUMED

TO PRODUCE 100% OF RATED OUTPUT. AN APPROPRIATE BALLAST FACTOR MUST BE APPLIED TO THE LUMEN OUTPUT

RATINGS AND LUMINOUS INTENSITY VALUES GIVEN. 3) THIS TEST WAS CONDUCTED IN A CONTROLLED LABORATORY

ENVIRONMENT WHERE THE AMBIENT TEMPERATURE WAS HELD AT 25�C � 1�C. FIELD PERFORMANCE MAY DIFFER PARTICULARLY

IN REGARDS TO CHANGE IN LUMINOUS OUTPUT AS A RESULT OF DIFFERENCE IN AMBIENT TEMPERATURE AND METHOD OF

MOUNTING THE LUMINAIRE.

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09334 DATE: 10-26-2005

PREPARED FOR: ENERCON/HIBRITE INTERNATIONAL

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 70 50 30 10 0

RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 113113113113 110110110110 105105105 101101101 97 97 97 95

1 104 99 96 92 101 97 94 91 93 91 88 90 87 85 86 84 83 81

2 95 88 82 77 93 86 81 76 83 78 74 80 76 73 77 74 71 69

3 88 78 71 66 85 77 70 65 74 69 64 72 67 63 69 65 62 60

4 81 70 62 56 79 69 62 56 67 60 55 64 59 55 62 58 54 52

5 74 63 54 49 72 62 54 48 60 53 48 58 52 47 56 51 47 45

6 69 57 48 43 67 56 48 42 54 47 42 52 46 42 51 46 41 40

7 64 51 43 38 62 50 43 37 49 42 37 48 42 37 46 41 37 35

8 59 46 38 33 57 46 38 33 44 38 33 43 37 33 42 37 32 31

9 54 42 34 29 53 41 34 29 40 33 29 39 33 29 38 33 28 27

10 51 38 31 26 49 38 31 26 37 30 26 36 30 26 35 29 25 24

CANDELA DISTRIBUTION0.0 22.5 45.0 67.5 90.0

0 2543 2543 2543 2543 25435 2521 2528 2528 2503 2499

10 2490 2476 2433 2380 237315 2432 2386 2311 2235 220120 2349 2268 2160 2001 194625 2247 2136 1938 1764 171930 2125 1984 1709 1558 152735 1982 1793 1496 1370 131240 1827 1567 1304 1135 109145 1659 1339 1094 956 94850 1472 1120 880 846 84655 1272 916 729 731 74260 1063 714 617 663 70965 850 512 519 624 65870 625 375 480 531 55275 420 274 386 418 44080 216 216 270 301 31685 57 110 147 150 15390 0 6 13 14 20

ZONAL LUMEN SUMMARY0- 5 61.5- 10 177.

10- 15 282.15- 20 368.20- 25 431.25- 30 471.30- 35 495.35- 40 492.40- 45 469.45- 50 437.50- 55 400.55- 60 362.60- 65 320.65- 70 279.70- 75 229.75- 80 170.80- 85 108.85- 90 32.

THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.

CHECKED BY

TESTED BY HERSCHEL SCHRECK

MIKE GRATHER

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09300 DATE: 10-11-2005PREPARED FOR: ENERCON/HIBRITE INTERNATIONALCATALOG NUMBER: HF8-4LUMINAIRE: FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM REFLECTOR,

NO ENCLOSURE.LAMPS: FOUR 32 WATT T8 LINEAR FLUORESCENT LAMPS RATED AT 2950 LUMENS

EACH.LAMP CATALOG NUMBER: PHILIPS F32T8/TL850/PLUS/ALTOBALLAST: ONE ADVANCE ICN-4P32-SCMOUNTING: PENDANT

LUMEN TO CANDELA RATIO USED = 9.18TOTAL INPUT WATTS =110.3 AT 120.0 VOLTSTHE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS.

CANDELA DISTRIBUTION FLUX0.0 22.5 45.0 67.5 90.0

0 4866 4866 4866 4866 48665 4837 4859 4884 4904 4920 46815 4664 4796 4811 4572 4493 132125 4321 4469 3995 3771 3721 187535 3825 3664 3269 3066 2968 209545 3194 2832 2466 2226 2154 196955 2465 2037 1651 1468 1503 160665 1643 1178 1072 1161 1173 118975 812 553 642 669 674 69285 118 162 190 206 207 20690 0 9 12 25 27

ZONAL LUMEN SUMMARYZONE LUMENS %LAMP %FIXT0- 30 3663 31.0 32.10- 40 5758 48.8 50.40- 60 9333 79.1 81.70- 90 11420 96.8 100.090-180 0 0.0 0.00-180 11420 96.8 100.0

TOTAL LUMINAIRE EFFICIENCY: 96.8%CIE TYPE: DIRECTPLANE: 0-DEG 90-DEGSPACING CRITERIA: 1.2 1.1LUMINOUS LENGTH: 48.250 14.000

LUMINANCE IN CANDELA PER SQUARE METERANGLE AVERAGE AVERAGE AVERAGEIN DEG 0-DEG 45-DEG 90-DEG

0 11165. 11165. 11165.45 10364. 8002. 6989.55 9861. 6604. 6012.65 8920. 5820. 6368.75 7198. 5691. 5975.85 3106. 5002. 5449.

1060

2120

3180

4240

0 15 30

45

60

75

90

105120135150165180

0 Deg. Plane 90 Deg. Plane

3.500" 3.500" 3.500"

14.000"

15.875"

2.2

50"

0.6

25"

1.5

00"

#09300

THIS TEST WAS CONDUCTED USING RELATIVE PHOTOMETRY TECHNIQUES ACCORDING TO STANDARD IESNA PROCEDURES. THE

USER MUST THEREFORE USE CAUTION IN THE FOLLOWING SITUATIONS: 1) THIS TEST WAS PERFORMED USING A

SPECIFIC BALLAST/LAMP COMBINATION. EXTRAPOLATION OF THESE DATA FOR OTHER BALLAST/LAMP COMBINATIONS MAY

PRODUCE ERRONEOUS RESULTS. 2) ACCORDING TO IESNA PROCEDURES, THE BALLAST(S) AND LAMP(S) ARE PRESUMED

TO PRODUCE 100% OF RATED OUTPUT. AN APPROPRIATE BALLAST FACTOR MUST BE APPLIED TO THE LUMEN OUTPUT

RATINGS AND LUMINOUS INTENSITY VALUES GIVEN. 3) THIS TEST WAS CONDUCTED IN A CONTROLLED LABORATORY

ENVIRONMENT WHERE THE AMBIENT TEMPERATURE WAS HELD AT 25�C � 1�C. FIELD PERFORMANCE MAY DIFFER PARTICULARLY

IN REGARDS TO CHANGE IN LUMINOUS OUTPUT AS A RESULT OF DIFFERENCE IN AMBIENT TEMPERATURE AND METHOD OF

MOUNTING THE LUMINAIRE.

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09300 DATE: 10-11-2005

PREPARED FOR: ENERCON/HIBRITE INTERNATIONAL

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 70 50 30 10 0

RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 115115115115 113113113113 108108108 103103103 99 99 99 97

1 106102 99 95 104100 97 94 96 93 91 92 90 88 89 87 85 84

2 98 91 85 80 95 89 84 79 86 81 77 83 79 75 80 77 74 72

3 90 81 74 68 88 80 73 68 77 71 66 74 69 65 72 68 64 62

4 83 73 65 59 81 71 64 58 69 63 58 67 61 57 65 60 56 54

5 76 65 57 51 74 64 56 50 62 55 50 60 54 49 58 53 49 47

6 71 58 50 44 69 58 50 44 56 49 44 54 48 43 53 47 43 41

7 65 53 45 39 64 52 44 39 51 44 39 49 43 38 48 42 38 36

8 60 48 40 34 59 47 39 34 46 39 34 45 38 34 43 38 33 32

9 56 43 35 30 54 42 35 30 41 34 30 40 34 29 39 33 29 28

10 52 39 32 27 51 39 31 26 38 31 26 37 31 26 36 30 26 24

CANDELA DISTRIBUTION0.0 22.5 45.0 67.5 90.0

0 4866 4866 4866 4866 48665 4837 4859 4884 4904 4920

10 4767 4827 4950 4970 495315 4664 4796 4811 4572 449320 4514 4707 4399 4155 409325 4321 4469 3995 3771 372130 4089 4088 3617 3457 340835 3825 3664 3269 3066 296840 3524 3243 2909 2636 254745 3194 2832 2466 2226 215450 2844 2436 2049 1826 172355 2465 2037 1651 1468 150360 2059 1603 1237 1378 140665 1643 1178 1072 1161 117370 1218 802 885 909 92475 812 553 642 669 67480 442 365 410 431 43885 118 162 190 206 20790 0 9 12 25 27

ZONAL LUMEN SUMMARY0- 5 116.5- 10 351.

10- 15 572.15- 20 748.20- 25 887.25- 30 988.30- 35 1044.35- 40 1051.40- 45 1020.45- 50 949.50- 55 847.55- 60 759.60- 65 651.65- 70 538.70- 75 406.75- 80 286.80- 85 159.85- 90 47.

THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.

CHECKED BY

TESTED BY HERSCHEL SCHRECK

MIKE GRATHER

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09301 DATE: 10-11-2005PREPARED FOR: ENERCON/HIBRITE INTERNATIONALCATALOG NUMBER: HF8-6LUMINAIRE: FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM REFLECTOR,

NO ENCLOSURE.LAMPS: SIX 32 WATT T8 LINEAR FLUORESCENT LAMPS RATED AT 2950 LUMENS

EACH.LAMP CATALOG NUMBER: PHILIPS F32T8/TL850/PLUS/ALTOBALLASTS: TWO FULHAM WORKHORSE WH5-120-LMOUNTING: PENDANT

LUMEN TO CANDELA RATIO USED = 9.18TOTAL INPUT WATTS =205.0 AT 120.0 VOLTSTHE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS.

CANDELA DISTRIBUTION FLUX0.0 22.5 45.0 67.5 90.0

0 6883 6883 6883 6883 68835 6830 6866 6871 6883 6889 655

15 6583 6661 6603 6345 6249 182925 6094 6127 5557 5325 5253 261435 5386 5067 4594 4379 4294 295545 4494 3938 3558 3210 3105 280355 3463 2869 2360 2212 2204 230365 2321 1681 1554 1708 1727 172575 1154 800 956 1000 1029 101785 173 237 294 330 344 31590 4 8 17 30 35

ZONAL LUMEN SUMMARYZONE LUMENS %LAMP %FIXT0- 30 5098 28.8 31.40- 40 8053 45.5 49.70- 60 13159 74.3 81.10- 90 16215 91.6 100.0

90-180 0 0.0 0.00-180 16215 91.6 100.0

TOTAL LUMINAIRE EFFICIENCY: 91.6%CIE TYPE: DIRECTPLANE: 0-DEG 90-DEGSPACING CRITERIA: 1.2 1.1LUMINOUS LENGTH: 47.125 21.000

LUMINANCE IN CANDELA PER SQUARE METERANGLE AVERAGE AVERAGE AVERAGE

IN DEG 0-DEG 45-DEG 90-DEG0 10780. 10780. 10780.

45 9954. 7880. 6877.55 9456. 6444. 6018.65 8601. 5759. 6400.75 6983. 5785. 6227.85 3109. 5283. 6181.

1460

2920

4380

5840

7300

0 15 30

45

60

75

90

105120135150165180

0 Deg. Plane 90 Deg. Plane

3.500" 3.500" 3.500" 3.500" 3.500"

21.000"

#09301

0.6

25

"

1.5

00

"

2.2

50

"

THIS TEST WAS CONDUCTED USING RELATIVE PHOTOMETRY TECHNIQUES ACCORDING TO STANDARD IESNA PROCEDURES. THE

USER MUST THEREFORE USE CAUTION IN THE FOLLOWING SITUATIONS: 1) THIS TEST WAS PERFORMED USING A

SPECIFIC BALLAST/LAMP COMBINATION. EXTRAPOLATION OF THESE DATA FOR OTHER BALLAST/LAMP COMBINATIONS MAY

PRODUCE ERRONEOUS RESULTS. 2) ACCORDING TO IESNA PROCEDURES, THE BALLAST(S) AND LAMP(S) ARE PRESUMED

TO PRODUCE 100% OF RATED OUTPUT. AN APPROPRIATE BALLAST FACTOR MUST BE APPLIED TO THE LUMEN OUTPUT

RATINGS AND LUMINOUS INTENSITY VALUES GIVEN. 3) THIS TEST WAS CONDUCTED IN A CONTROLLED LABORATORY

ENVIRONMENT WHERE THE AMBIENT TEMPERATURE WAS HELD AT 25�C � 1�C. FIELD PERFORMANCE MAY DIFFER PARTICULARLY

IN REGARDS TO CHANGE IN LUMINOUS OUTPUT AS A RESULT OF DIFFERENCE IN AMBIENT TEMPERATURE AND METHOD OF

MOUNTING THE LUMINAIRE.

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09301 DATE: 10-11-2005

PREPARED FOR: ENERCON/HIBRITE INTERNATIONAL

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 70 50 30 10 0

RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 109109109109 107107107107 102102102 97 97 97 93 93 93 92

1 101 97 93 90 98 95 91 89 91 88 86 87 85 83 84 82 81 79

2 93 86 80 75 90 84 79 74 81 76 73 78 74 71 75 72 69 68

3 85 76 70 64 83 75 69 64 72 67 62 70 65 61 68 64 60 59

4 78 68 61 55 76 67 60 55 65 59 54 63 58 53 61 56 53 51

5 72 61 53 47 70 60 53 47 58 52 47 56 51 46 55 50 46 44

6 67 55 47 41 65 54 47 41 52 46 41 51 45 41 50 44 40 38

7 62 50 42 36 60 49 42 36 47 41 36 46 40 36 45 40 36 34

8 57 45 37 32 55 44 37 32 43 36 32 42 36 31 41 35 31 29

9 52 40 33 28 51 40 33 28 39 32 28 38 32 27 37 31 27 26

10 49 37 30 25 48 36 29 25 35 29 25 35 29 24 34 28 24 23

CANDELA DISTRIBUTION0.0 22.5 45.0 67.5 90.0

0 6883 6883 6883 6883 68835 6830 6866 6871 6883 6889

10 6743 6778 6827 6826 680315 6583 6661 6603 6345 624920 6364 6465 6076 5794 571825 6094 6127 5557 5325 525330 5764 5613 5074 4871 480035 5386 5067 4594 4379 429440 4960 4504 4105 3826 370145 4494 3938 3558 3210 310550 3996 3415 2956 2649 255055 3463 2869 2360 2212 220460 2891 2289 1834 1978 200765 2321 1681 1554 1708 172770 1727 1159 1296 1357 138375 1154 800 956 1000 102980 619 531 627 676 68285 173 237 294 330 34490 4 8 17 30 35

ZONAL LUMEN SUMMARY0- 5 165.5- 10 490.

10- 15 793.15- 20 1037.20- 25 1234.25- 30 1379.30- 35 1466.35- 40 1490.40- 45 1450.45- 50 1353.50- 55 1220.55- 60 1083.60- 65 943.65- 70 782.70- 75 599.75- 80 419.80- 85 243.85- 90 71.

THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.THIS REPORT BASED ON LM-41 AND OTHER PERTINENT IESNA PROCEDURES.

CHECKED BY

TESTED BY HERSCHEL SCHRECK

MIKE GRATHER

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09335 DATE: 10-26-2005PREPARED FOR: ENERCON/HIBRITE INTERNATIONALCATALOG NUMBER: EF8-6LUMINAIRE: FORMED STEEL HOUSING, FORMED SPECULAR ALUMINUM REFLECTOR,

NO ENCLOSURE.LAMPS: SIX 32 WATT T8 LINEAR FLUORESCENT LAMPS RATED AT 2950 LUMENS

EACH.LAMP CATALOG NUMBER: PHILIPS F32T8/TL850/PLUS/ALTOBALLASTS: TWO ADVANCE ICN-4P32-SCMOUNTING: PENDANT

LUMEN TO CANDELA RATIO USED = 9.18TOTAL INPUT WATTS =179.1 AT 120.0 VOLTSTHE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS.

CANDELA DISTRIBUTION FLUX0.0 22.5 45.0 67.5 90.0

0 6935 6935 6935 6935 69355 6886 6917 6912 6904 6898 656

15 6636 6655 6505 6260 6164 181725 6141 6043 5489 5262 5161 258435 5420 5001 4478 4158 4050 287445 4499 3912 3353 2968 2813 267955 3423 2735 2144 2036 2022 216865 2258 1586 1410 1429 1421 154975 1090 719 757 788 799 85485 143 183 211 224 230 23190 0 0 0 0 0

ZONAL LUMEN SUMMARYZONE LUMENS %LAMP %FIXT0- 30 5058 28.6 32.80- 40 7932 44.8 51.50- 60 12779 72.2 82.90- 90 15413 87.1 100.0

90-180 0 0.0 0.00-180 15413 87.1 100.0

TOTAL LUMINAIRE EFFICIENCY: 87.1%CIE TYPE: DIRECTPLANE: 0-DEG 90-DEGSPACING CRITERIA: 1.2 1.0LUMINOUS LENGTH: 48.000 20.750

LUMINANCE IN CANDELA PER SQUARE METERANGLE AVERAGE AVERAGE AVERAGE

IN DEG 0-DEG 45-DEG 90-DEG0 10792. 10792. 10792.

45 9901. 7379. 6190.55 9287. 5817. 5486.65 8314. 5192. 5232.75 6553. 4551. 4804.85 2553. 3767. 4107.

1480

2960

4440

5920

0 15 30

45

60

75

90

105120135150165180

0 Deg. Plane 90 Deg. Plane

3.500" 3.500" 3.500" 3.500" 3.500"

20.750"

22.000"

1.2

50

"

2.0

00

"

3.6

25

"

#09335

THIS TEST WAS CONDUCTED USING RELATIVE PHOTOMETRY TECHNIQUES ACCORDING TO STANDARD IESNA PROCEDURES. THE

USER MUST THEREFORE USE CAUTION IN THE FOLLOWING SITUATIONS: 1) THIS TEST WAS PERFORMED USING A

SPECIFIC BALLAST/LAMP COMBINATION. EXTRAPOLATION OF THESE DATA FOR OTHER BALLAST/LAMP COMBINATIONS MAY

PRODUCE ERRONEOUS RESULTS. 2) ACCORDING TO IESNA PROCEDURES, THE BALLAST(S) AND LAMP(S) ARE PRESUMED

TO PRODUCE 100% OF RATED OUTPUT. AN APPROPRIATE BALLAST FACTOR MUST BE APPLIED TO THE LUMEN OUTPUT

RATINGS AND LUMINOUS INTENSITY VALUES GIVEN. 3) THIS TEST WAS CONDUCTED IN A CONTROLLED LABORATORY

ENVIRONMENT WHERE THE AMBIENT TEMPERATURE WAS HELD AT 25�C � 1�C. FIELD PERFORMANCE MAY DIFFER PARTICULARLY

IN REGARDS TO CHANGE IN LUMINOUS OUTPUT AS A RESULT OF DIFFERENCE IN AMBIENT TEMPERATURE AND METHOD OF

MOUNTING THE LUMINAIRE.

905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com905 Harrison Street · Allentown, PA 18103 · 610-770-1044 · Fax 610-770-8912 · www.LuminaireTesting.com

SUSTAINING

MEMBER

of the

IESNA

SUSTAINING

MEMBER

of the

IESNALUMINAIRE TESTING LABORATORY, INC.LUMINAIRE TESTING LABORATORY, INC.

LTL NUMBER: 09335 DATE: 10-26-2005

PREPARED FOR: ENERCON/HIBRITE INTERNATIONAL

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 70 50 30 10 0

RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 104104104104 101101101101 97 97 97 93 93 93 89 89 89 87

1 96 92 89 86 94 90 87 85 87 84 82 83 81 80 80 79 77 76

2 88 82 77 72 86 81 76 72 77 73 70 75 71 68 72 69 67 65

3 82 73 67 62 80 72 66 62 70 65 60 67 63 59 65 62 58 57

4 75 66 59 54 73 65 58 53 63 57 53 61 56 52 59 55 51 49

5 69 59 52 46 67 58 51 46 56 50 45 54 49 45 53 48 44 43

6 64 53 46 41 62 52 45 40 51 45 40 49 44 40 48 43 39 38

7 59 48 41 36 58 47 40 36 46 40 35 45 39 35 44 39 35 33

8 55 43 36 31 53 43 36 31 42 35 31 41 35 31 40 34 31 29

9 51 39 32 27 49 39 32 27 38 31 27 37 31 27 36 31 27 25

10 47 36 29 24 46 35 29 24 34 28 24 34 28 24 33 28 24 22

CANDELA DISTRIBUTION0.0 22.5 45.0 67.5 90.0

0 6935 6935 6935 6935 69355 6886 6917 6912 6904 6898

10 6791 6823 6791 6737 670715 6636 6655 6505 6260 616420 6419 6405 6002 5722 565025 6141 6043 5489 5262 516130 5808 5562 5024 4710 460635 5420 5001 4478 4158 405040 4981 4449 3915 3589 344845 4499 3912 3353 2968 281350 3978 3343 2757 2388 231455 3423 2735 2144 2036 202260 2855 2158 1691 1765 176965 2258 1586 1410 1429 142170 1669 1047 1088 1089 108975 1090 719 757 788 79980 567 427 486 529 53685 143 183 211 224 23090 0 0 0 0 0

ZONAL LUMEN SUMMARY0- 5 166.5- 10 491.

10- 15 787.15- 20 1030.20- 25 1224.25- 30 1360.30- 35 1433.35- 40 1441.40- 45 1394.45- 50 1285.50- 55 1152.55- 60 1016.60- 65 863.65- 70 686.70- 75 505.75- 80 349.80- 85 190.85- 90 42.