PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf ·...

21
PRODUCT LINEUP SYMBOLS Listed File No. E 74253 File No. E 78637 File No. E101181 Certified File No. LR 60232 File No. LR 61076 VDE File No.19442-1432-1001/A2C File No.19442-1431-0001/328BF (Conforms to DIN / VDE:1991-09) File No. R 9154191 File No. R 9154193 File No. R 9154195 File No. R 9154197 File No. R 9154199 File No. R 9254037 File No. R 9254038 File No. R 9254039 File No. R 9554069 File No. R 9554166 (Conforms to DIN / VDE 0627) (Conforms to DIN / VDE 0470) TUV Licensed : UL CSA TUV VDE UL, CSA UL, VDE : TUV, CSA : TUV, CSA, VDE : UL, TUV : TUV, VDE : UL, CSA, VDE UL, TUV, VDE : UL, CSA, TUV : UL, CSA, TUV, VDE : : KOREA ELECTRIC TERMINAL CO., LTD. TRADE MARK : KSA 9001 : 1995, ISO 9001 : 1994, EN ISO : 1994 CERTIFICATE NO:AC-00200 : ISO 9001 : 1994, EN ISO : 1994 , KSA 9001 : 1998, QS-9000 CERTIFICATE NO:MC-00200 KET, 1

Transcript of PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf ·...

Page 1: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

▶SYMBOLSListedFile No. E74253File No. E78637File No. E101181

CertifiedFile No. LR60232File No. LR61076

VDE File No.19442-1432-1001/A2CFile No.19442-1431-0001/328BF(Conforms to DIN/VDE:1991-09)

File No. R9154191File No. R9154193File No. R9154195File No. R9154197File No. R9154199File No. R9254037File No. R9254038File No. R9254039File No. R9554069File No. R9554166(Conforms to DIN/VDE 0627)(Conforms to DIN/VDE 0470)

TUV Licensed

:

UL

CSA

TUV

VDE

UL, CSA

UL, VDE

:

TUV, CSA

:

TUV, CSA, VDE

:

UL, TUV

:

TUV, VDE

:

UL, CSA, VDE

UL, TUV, VDE

:

UL, CSA, TUV

:

UL, CSA, TUV, VDE

:

: KOREA ELECTRIC TERMINAL CO., LTD. TRADE MARK

: KSA 9001:1995, ISO 9001:1994, EN ISO:1994 CERTIFICATE NO:AC-00200

: ISO 9001 :1994, EN ISO:1994 , KSA 9001:1998, QS-9000 CERTIFICATE NO:MC-00200

KET,

1

Page 2: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

▶STRIP TERMINAL, HOUSING FEATURES

HOUSING TERMINAL

●PLUG ●RECEPTACLE

●RECEPTACLE ●TAB

●PART NUMBER SYSTEM ●PART NUMBER SYSTEM

BEAK-2

KEY

BEAK-1

CLIP LOCKING HOOK

REAR HOLDER

LOCKING HOOK-1(REAR HOLDER)

LANCE

GUIDE

HINGE

HOOK

LOCKING ARM-2(REAR HOLDER)

LOCKING ARM-1(REAR HOLDER)

SERRATION

INSULATION BARREL

STABILIZER

CHAMFER

LOCKING HOLE

WIRE BARREL

DOT

SWAGINGSLOT

CURLING

DIMPLE

CUTTING

LOCKING LEVER

LOCKING ARM-1(REAR HOLDER)

LOCKING ARM-2(REAR HOLDER)

LOCKING HOOK(REAR HOLDER)

LANCE

HINGE

HOOK

KEY-Ⅱ

BEAK-2

KEY-Ⅰ

STOPPER-1

BEAK-1

STOPPER-2

REAR HOLDER

SERRATION

INSULATIONBARREL

WIRE BARREL

1. HOUSING

MG 6 1 0000 - 1

1.Plug

2.Receptacle

3.Holder & Clip

4.Receptacle Ass'y

5.Plug Ass'y

6.Others Ass'y

8.Rubber Seal

Mold General

1. Red

11.Orange

2. Blue

3. Yellow

4. Gray

40.Dark Gray

41.Light Gray

5. Black

6. Green

7. Brown

8. Light Green

9. Magenta

2. STRIP TERMINAL

ST 7 1 0000 - 1

1.Ring

2.Spade

3.Receptacle

4.Tab

5.Pin

6. Splice & Button

8.Fuse & etc.

Strip Terminal

1.Brass

2.Brass/Tin

3.Pre-Tin

G.Au/Ni

GS.Au/Sn-Pb

Serial Number

Product Number Product Number

Serial Number

PRODUCT LINEUP

2

Page 3: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

▶CRIMPING SPECIFICATION

▶WIRE CRIMPING SHAPE ▶FORCES FOR CRIMP PULL-OUT TEST

▶ INSULATION CRIMPING SHAPE

▶NOMENCLATURE ▶CRIMPING CONDITIONS

②TWISTING

③ROLLING

⑦CONDUCTOR CRIMP HEIGHT

⑧ INS. CRIMP HEIGHT

④CUT-OFF TAB LENGTH

⑤BELLMOUTH

⑥EXTRUDED WIRE LENGTH

①BEND UP

BEND DOWN

Check Point

Bend-up

Bend-Down

Twisting

Rolling

Cut-Off Tab Length

Bellmouth

Extruded Wire Length

Wire Strip Length

Requirements

3-6°MAX

3-6°MAX

3-6°MAX

0.5mm MAX

0.5mm-0.65mm

0-2mm

4.5mm-5.5mm

3-6°MAX

“F”CRIMP “C”CRIMP

Standard SDL 250D/L WP

wire size

mm2 AWG Pounds kg

0.3 22 8 3.6

0.5 20 13 5.9

0.85 18 20 9.1

1.25 16 30 13.6

2.0 14 50 22.7

3.0 12 70 31.8

5.0 10 80 36.3

Standard/Minimum0.3~0.8mm

3

Page 4: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

▶PRODUCT / MOLD DESIGN

▶CAE ANALYSIS

PRODUCT LINEUP

4

Tool Server

DATA StorageServer

9 Tools

PRODUCT DESIGN

CATIA, Pro-E, Autocad

CIRCUIT DESIGN

Prote, Power-PCB

MOLD DESIGN

UG, Mold Manufacture, Solid Works

TOOLING S/W

UG, CAM S/W

PRODUCT ANALYSIS HEAT ANALYSISCAE ToolsABAQUSMoldFlow

View port:1 Model:Model1 Module:Visualization

MO

LD

MA

NU

FA

CT

UR

E

FLOW ANALYSIS

Page 5: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

5

▶PRELIMINARY VERIFICATION

Deflection X Deflection Y Deflection Z

위의 그림은 Warpage 해석 결과, 각각 X, Y, Z, 방향으로 변형을 나타낸다.변형량은 각 방향으로 약 0.5mm이하로 대체적으로 변형 발생이 크지 않음을 알 수 있다.

TEST ANALYSIS

MOLDFLOW

ABAQUS

Warpage

The Result of a Verification Analysis and Test

Insertion Force 3.70(kg) 3.20(kg)

Separation Force 2.30(kg) 2.33(kg)

As a result of the analysis of Warpage, above figure shows that the deformation of each direction X,Y,Z. The deformation is the less than 0.5mm, it doesn't happen frequently.

Page 6: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

6

▶ENGINEERING POLYMER CHOICE

PBT

PA96, 66, 460

LCP

CONN'T Ordinary raw material(Incombustible, Combustible)-Use in CONN'T of ENGINE ROOMCONN'T Ordinary raw material(Incombustible, Combustible)-Use in CONN'T of UNIT and SENSOR

Excellent super POLYMER in a function(Heat&Strength) and a productivity

▶Terminal Raw Material Characteristic Comparison

Application trend EUROPE KOREA, JAPAN COMMONNESS U.S.A

STOL76(C19010)

STOL79(C19400)

MAX251-H(C72500)

MSP1-HPMC26-H(C64750)

NB109-H(C19025)

KL109-H(C50715)

C2600-H Ph, Bz-H

Chemical Composition(wt%)

Tensile Strength(kgf/mm2)

Yield Strength(kgf/mm2)

Elongation(%)

Electrical(wt% IACS)

Vickers Hardness(Hv)

Residual Stress with Pre-stress(%, 150℃/1000h)

Spring Limit(kgf/mm2)

Thermal SofteningTemperature(℃/30min)

R/t(180。, GW/BW)

Ni 1.5Si 0.28P 0.03Cu Rem

60~67

56 Min

10 Min

60 Min

175~205

95

47

500

0.0/0.5

Fe 2.3P 0.08Zn 0.12Cu Rem

57~63

53 Min

9 Min

60 Min

158~190

90

40

450

0.0/1.0

Ni 1.5~2.7Si 0.2~0.8Zn 0.5~1.5Sn 0.2~0.8Cu Rem

67.5

60

15

38

199

90

45 Min

500

0.5/0.5

P 0.002~0.01Mg 0.5~0.8Cu Rem

53

49.5

11

62

162

78

37.5

-

0.5/1.0

Ni 1.7~2.0Si 0.25~0.4Sn 0.25~0.4Cu Rem

65.8

58.4

12

50

196

80

49

500

1.0/1.0

Ni 0.8~1.2Si 0.7~1.1P 0.03~0.07Cu Rem

53

52.5

10

40

165

98

40

430

0.5/2.0

Sn 1.5~2.5Fe 0.05~0.15P 0.03~0.04Cu Rem

58.2

53.5

12

35

177

65

50

420

0.0/1.0

Cu 70Fe 0.05 Pb 0.05 Zn Rem

50.8

46.2

19

28

173

75

32 Min

350

1.5/2.0

Sn 8.0Fe 0.1 P 0.2Zn 0.2 Pb 0.05Cu Rem

52~60

45 Min

6 Min

18 Min

170~190

50

35 Min

450

1.0/1.5

Page 7: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

7

CONNECTORTYPE

P-LOCK

312

250

110

APPEARANCEMATERIAL

TERMINAL

F : Brass / Pre-Tin

TERMINAL

F : Brass / Pre-TinHOUSING

: Nylon 66

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.P Rein forced

PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

.250

.187

.312

.250

3mΩ Max(Initial)

DC 500V100MΩ Min

0.5-5.0

0.3-2.0

0.3-5.0

0.3-3.0DC 500V

100MΩ Min3mΩ Max

(Initial)

42A

20A

▶ELECTRONIC APPLIANCES

24

~

26

27

250

TERMINAL

F : Brass / Pre-Tin

HOUSING: P.B.T

0.3-0.5DC 500V

100MΩ Min3mΩ Max

(Initial)20A.250

27

~

28

187

TERMINAL

F : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-3.0DC 500V

100MΩ Min3mΩ Max

(Initial)15A.187 30

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 6

0.3-1.5DC 500V

100MΩ Min3mΩ Max

(Initial)10A.110 31

Ø1.3

Ø2.0

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 6

0.3-1.25

0.2-2.0

DC 500V1,000MΩ Min

DC 500V1,000MΩ Min

10mΩ Max(Initial)

10mΩ Max(Initial)

10A

15A

Ø1.3

Ø2.0

34

~

35

36

~

37

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 8: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

1806 D/L

1806

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

.070 15A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)15A.070

44

47

~

49

1806 PCB

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: Nylon 66

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)15A.070

1006

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: Nylon

0.13-0.33DC 500V500MΩ Min

20mΩ Max(Initial)

3A.040

49

51

PRODUCT LINEUP

8

3220

0709

MULTI

TERMINALM : Phos.Bronze / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.8-2.4DC 500V

1,000MΩ Min5mΩ Max

(Initial)20A.125

TERMINALM : Copper Alloy / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-2.4DC 500V

1,000MΩ Min3mΩ Max

(Initial)15A

.090

.070

39

41

~

42

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 9: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

9

CONNECTORTYPE

375

312

312- II

APPEARANCE MATERIAL

TERMINALM : Copper Alloy / Pre-Tin

HOUSING: Nylon 66

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING

: Nylon 66

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

.375 60A 2mΩ Max(Initial)

DC 500V100MΩ Min

3.0-8.0

0.3-5.0

2.0-8.0

DC 500V100MΩ Min

DC 500V100MΩ Min

3mΩ Max(Initial)

3mΩ Max(Initial)

42A

42A

.312

.312

▶AUTOMOTIVE APPLIANCES

312- II WP

64

65

66

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

1.25-8.0DC 500V

100MΩ Min3mΩ Max

(Initial)42A.312

67

~

68

250 D/L

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-3.0DC 500V

100MΩ Min3mΩ Max

(Initial)20A.250 69

250-III

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-3.0DC 500V

100MΩ Min3mΩ Max

(Initial)20A.250 70

250

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-3.0DC 500V

100MΩ Min3mΩ Max

(Initial)20A.250

71

~

72

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 10: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

.250 20A 3mΩ Max(Initial)

DC 500V250MΩ Min

0.5-3.0250 WP 73

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

.187 28.5A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-3.0187-II WP 76

110 D/L

TERMINAL

F : Brass / Pre-Tin

HOUSING: Nylon 66

.110 10A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0 77

118

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.118

78

~

79

BS

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.118

80

~

81

110

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.110 82

110 WP

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: Nylon 66

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.110

83

~

84

PRODUCT LINEUP

10*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 11: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

11

CONNECTORTYPE APPEARANCE MATERIAL PAGE

CURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

ITC

TERMINAL

F : Brass / Copper Alloy

HOUSING: P.B.T

0.5-2.0DC 500V

250MΩ Min3mΩ Max

(Initial)10A.110

85

~

86

ESC

TERMINAL

F : Brass / Copper Alloy

HOUSING: P.B.T

0.3-2.0DC 500V

250MΩ Min3mΩ Max

(Initial)10A.110 87

090

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-1.25DC 500V

100MΩ Min3mΩ Max

(Initial)10A.090

88

~

89

090 WP

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

.090 10A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

90

~

91

ASC

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

.090 10A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

92

~

95

090- II

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.090

96

~

98

TLC

TERMINALM : Brass / Pre-Tin

HOUSING:P.B.T

0.5DC 500V

250MΩ Min10mΩ Max

(Initial)3A1.0Ø 84

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 12: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

0.3-3.0

0.3-2.0

0.3-2.0

DC 500V100MΩ Min

DC 500V100MΩ Min

3mΩ Max(Initial)

3mΩ Max(Initial)

20A

9A

9A

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

SDL-II

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

.070 9A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0 112

DOOR

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

.070 9A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

113

~

115

HYBRID

SDL

TERMINALM : Brass / Pre-TinF : Brass / Brass-Tin

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: Nylon 66

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

.312

.250

.187

.090

.070

.040

.070 9A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-2.0

107

~

108

109

~

111

42A

20A

20A

10A

9A

3A

PRODUCT LINEUP

090- II WP

HYBRID

DIODE

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-Tin

HOUSING: Nylon 66

0.3-2.0

0.3-2.0

0.3-1.25

DC 500V100MΩ Min

DC 500V100MΩ Min

DC 500V100MΩ Min

3mΩ Max(Initial)

3mΩ Max(Initial)

3mΩ Max(Initial)

10A

10A

.090

.090

.250

.187

.090

.070

12

99

~

100

101

102

~

106

20A

20A

10A

9A

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 13: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

13

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

SSD

TERMINAL

F : Copper Alloy / Pre-Tin

HOUSING: Nylon

0.3-0.85DC 500V

100MΩ Min3mΩ Max

(Initial)5A.050

050

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-0.5DC 500V100MΩ Min

5mΩ Max(Initial)

5A.050 122

123

~

124

OBD-II

SWP

060

TERMINAL

F : Copper Alloy / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

0.3-0.85

0.3-2.0

DC 500V100MΩ Min

DC 500V250MΩ Min

2mΩ Max(Initial)

3mΩ Max(Initial)

10A

9A

.070

.070

0.3-0.85DC 500V100MΩ Min

5mΩ Max(Initial)

6A.060

116

117

~

119

120

~

121

0509 WP

040 III

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

0.3-2.0

0.3-0.85DC 500V

100MΩ Min3mΩ Max

(Initial)

10A

5A

.090

.050 125

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

0.3-1.25DC 500V100MΩ Min

10mΩ Max(Initial)3A.040

126

~

127

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 14: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

CONNECTORTYPE APPEARANCE MATERIAL PAGE

CURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONSTERMINALTAB SIZE

TCU & ECU

93P, 119P

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

5A

7A..025

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

9A

5A

.070

.040TCU & ECU

64P, 76P

135

~

137

138

~

140

PRODUCT LINEUP

14

CLUSTER

TERMINALM : Copper Alloy / Pre-Tin

HOUSING: Nylon (Ⅱ): P.B.T (Ⅲ)

0.3-1.25DC 500V

100MΩ Min3mΩ Max

(Initial)10A

131

~

132

ECU 55P

ECU 88P

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

10A 3mΩ Max(Initial)

DC 500V100MΩ Min

0.3-1.25DC 500V

100MΩ Min3mΩ Max

(Initial)6A

133

134

040 WP(RK)

030

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-0.5DC 500V100MΩ Min

10mΩ Max(Initial)

3A.030

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

0.3-0.85DC 500V100MΩ Min

10mΩ Max(Initial)

3A.040

130

128

~

129

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 15: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

15

CONNECTORTYPE APPEARANCE MATERIAL PAGE

CURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

ASC WP

JOINT

JOINT

090

090-II

TERMINALM : Brass / Pre-TinF : Brass / Copper Alloy

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

10A.090 0.3-2.0

152

~

153

154

090-II

070

050

0407

0409

040-III

030

ASC-II

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)

10A

9A

5A

3A

.090

.070

.050

.040

.030

144

~

148

PCB

040

JOINT

070

TERMINALM : Brass / Pre-TinF : Brass / Copper Alloy

HOUSING: P.B.T

TERMINALM : Brass / Pre-TinF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

0.2-0.5DC 500V

100MΩ Min

DC 500V100MΩ Min

6mΩ Max(Initial)

3mΩ Max(Initial)

3A

9A

.040

.070

149

~

150

151

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING: P.B.T

TCU & ECU

81P, 121P

DC 500V100MΩ Min

3mΩ Max(Initial)

5A

10A

.025

.110

141

~

142

PCB

250

3mm

MCCP

TERMINALM : Brass / Pre-TinF : Phos.Bronze / Pre-Tin

HOUSING(MCCP): P.B.T

HOUSING(.250): Nylon66

0.3-1.25

0.3-3.0

DC 500V100MΩ Min

3mΩ Max(Initial)

20A

10A

.250

.086

143

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

PCB

TERMINALM : Brass / Pre-TinF : Brass / Pre-Tin

HOUSING: P.B.T

0.3-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.090

Page 16: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

16

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

164

~

166COVER

DEVICE

060-II

TERMINALM : Brass / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

6A.060 0.3-0.85 159

BULB

TERMINALM : Phos. Bronze

HOUSINGFRT : P.B.TRCL : Nylon 66

.070

160

~

161

HEAD-LAMP

TERMINAL

F : Copper Alloy / Pre-Tin

HOUSING: Nylon 66

0.5-2.0DC 500V

100MΩ Min3mΩ Max

(Initial)10A.110 162

DEVICE

FUEL PUMP

AMPHIASTER

TERMINALF : Brass / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

0.3-2.0

157

~

158

RELAY

TERMINALF : Copper Alloy / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

0.3-3.0 156

42A

20A

20A

.312

.250

.090

EARTH

TERMINALM : Copper Alloy / Pre-Tin

HOUSING: P.B.T

DC 500V100MΩ Min

3mΩ Max(Initial)

0.3-3.0 155

20A

20A

10A

.250

.187

.090

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 17: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

17

CONNECTORTYPE

APPEARANCE MATERIAL PAGECURRENTRATING

CONTACTRESISTANCE

INSULATIONRESISTANCE

WIRESIZE

SPECIFICATIONS

TERMINALTAB SIZE

BOX

UNIT

&

MODULE

REWORK

JIG

167

168

~

169

196

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 18: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

18

CONNECTOR TYPE MATERIAL

Brass / Pre-Tin

WIRE SIZE APPEARANCE PAGE

BULLET TERMINAL

RING TERMINAL

EARTH TERMINAL

FUSE TERMINAL

CONNECTOR TYPE NAME

NON-INSULATED

NON-INSULATED

INSULATED

INSULATED

NON-INSULATED

INSULATED

NON-INSULATED

INSULATED

INSULATED

INSULATED

PVC (VINYL)SLEEVE TERMINAL

PVC (VINYL)SLEEVE TERMINAL

PVC (VINYL)SLEEVE TERMINAL

PVC (VINYL)SLEEVE TERMINAL

PVC (VINYL)SLEEVE

NYLON & VINYLSLEEVE TERMINAL

PVC (VINYL)SLEEVE TERMINAL

EXTRA COPPERSLEEVE

CONSTITUTION APPEARANCE PAGE

RING TERMINAL

SPADE & FLANGEDTERMINAL

HOOK, ROUND & LOCKING SPADE TERMINAL

BLADE, PIN & LOCKING SPADE TERMINAL

QUICK-CONNECT PIN & REC. TERMINALFULLY .156 .180 .195

FULLY .250 & CLOSED-END CONNECTOR

ECS TERMINALS

0.3 ~ 8.0

Brass / Brass-TinSPLICE 0.2 ~ 18.0

Brass / Pre-TinPIN & RECEPTACLETERMINAL

0.5 ~ 2.27

Brass / Brass-Tin / Pre-Tin 0.2 ~ 8.4

Brass / Pre-Tin 0.5 ~ 8.0

Brass / Pre-Tin 0.5 ~ 5.27

50

149

46~

47

48

51~

53

144

147~

148

153

154

155

156

157

158

159

160

161

162

163~

164

165~

171

*Allowable current varies depending upon the No. of poles used, size of the wire, Time elapsed, temperature etc.

Page 19: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

Wire Size(mm2) 8.00

Connector Series .375

PRODUCT LINEUP

19

▶TEMPERATURE RISE

60Current Rating(A)

Type Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 8.00

Connector Series .375Type Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 8.00

Connector Series .312IIType Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 8.00

Connector Series .312IIType Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series .250Type Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series .250Type Waterproof

Application Temperture(℃) 105

Connector & Environment Information

KET .375 Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

실험데이터를 근거로 작성된 것으로, 차량 장착시 다소 다른 결과를 나타낼 수 있습니다.The test result was drawn up under certain testing condition, the results can be different when installed in the car.

60Current Rating(A)

KET .375 W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

42Current Rating(A)

KET .312II Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

42Current Rating(A)

KET .312II W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

20Current Rating(A)

KET .250 Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

20Current Rating(A)

KET .250 W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

Page 20: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

20

28Current Rating(A)

KET .187II Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

28Current Rating(A)

KET .187II W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

10Current Rating(A)

KET .090II Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

10Current Rating(A)

KET .090II W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

10Current Rating(A)

KET ASC Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

10Current Rating(A)

KET ASC W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

Wire Size(mm2) 3.00

Connector Series .187IIType Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series .187IIType Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series .090IIType Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series .090IIType Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series ASCType Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 3.00

Connector Series ASCType Waterproof

Application Temperture(℃) 105

Connector & Environment Information

실험데이터를 근거로 작성된 것으로, 차량 장착시 다소 다른 결과를 나타낼 수 있습니다.The test result was drawn up under certain testing condition, the results can be different when installed in the car.

Page 21: PRODUCT LINEUP - ST Systemsstsystems.co.kr/Catalog/KET/KET_Catalog_Product_Lineup.pdf · 2010-10-19 · product lineup crimping specification wire crimping shape forces for crimp

PRODUCT LINEUP

21

9Current Rating(A)

KET .070 Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

9Current Rating(A)

KET .070 W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

3Current Rating(A)

KET .050 Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

5Current Rating(A)

KET .050 W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

3Current Rating(A)

KET .040III Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

3Current Rating(A)

KET .040III W/P Wire to Wire Conn’t Temperature Rise

Current

Tem

pera

ture

Ris

e

Wire Size(mm2) 2.00

Connector Series .070Type Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 2.00

Connector Series .070Type Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 0.50

Connector Series .050Type Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 0.50

Connector Series .050Type Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 0.50

Connector Series .040IIIType Non-Waterproof

Application Temperture(℃) 105

Connector & Environment Information

Wire Size(mm2) 0.50

Connector Series .040IIIType Waterproof

Application Temperture(℃) 105

Connector & Environment Information

실험데이터를 근거로 작성된 것으로, 차량 장착시 다소 다른 결과를 나타낼 수 있습니다.The test result was drawn up under certain testing condition, the results can be different when installed in the car.