Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2...

81
1 We are all making efforts to deal responsibly with our resources and with nature. Much has already been achieved in this respect. Presentation of Waste incineration technologies from Lentjes GmbH

Transcript of Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2...

Page 1: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

1

We are all making efforts to dealresponsibly with our resources andwith nature. Much has already beenachieved in this respect.

Presentationof

Waste incineration technologiesfrom

Lentjes GmbH

Page 2: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

2

1. Company and Plant References2. Technologies3. Summary

Page 3: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

3

1. Company and Plant References

Page 4: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

4

Lentjes?

A few words about the company …

Page 5: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

5

Lentjes GmbH

Ø Lentjes is a process lead international EPC turnkeycontractor with a worldwide network in industrially activemarkets

Ø Lentjes is a pure engineering company with in-houseproprietary technologies and processes for EfW plants (gratesystems, steam generators, FGC systems)

Ø Over 80 contracts in the waste to energy sector since 1990Ø Wide international experienceØ Involvement in early stage regarding planning questionsØ Local presence in key markets ensures deliverability

Page 6: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

6

Ø Engineering (for all combustion systems, boilers, FGCprocesses, civils, water-steam-cycle, electrical, I&C, etc.)

Ø Procurement / International SourcingØ ConstructionØ Project ManagementØ Quality Assurance / Health & SafetyØ Construction ManagementØ Training, Commissioning, Performance Testing

Turnkey EPC Expertise in

Page 7: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

7

GEA Group AktiengesellschaftTurnover €4.5 billion Employees 17,500

ProcessEquipment

MechanicalSeparation

Dairy FarmSystems

ProcessEquipment

ProcessEngineering

ProcessEquipment

EnergyTechnology

CustomisedSystems

Refrigeration

Air Treatment

PlantEngineering

Lentjes GmbHTurnover ~ €350 m

350 employees

Lurgi AG

Zimmer AG

Lurgi Bischoff GmbH

Page 8: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

8

Latest News ….

Ø GEA has decided to concentrate on the component business,thus the Plant Engineering Division has been sold

Ø Lentjes has recently found new owner in ATEC Industries

Ø ATEC Industries will continue and strengthen all formerLentjes’ activities in the future

Ø Lentjes will remain a strong and reliable partner in the‘Energy from Waste’ business

Page 9: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

9

Headquarters Ratingen / Germany

Page 10: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

10

Lentjes Portfolio

Energy Division

Ø Fossil Fired Power Plants

Ø Combined Cycle Power Plants

Ø Flue Gas Desulphurisation

Environment Division

Ø Hazardous Waste Incineration

Ø Biomass to Energy

Ø Sewage Sludge Incineration

Ø Energy from Waste

Page 11: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

11

Lentjes Product Portfolio

Fossil FiredPower Plants

Circulating FluidisedBed

Combined CyclePower Plants

Co-Generation andIndustrial Power

Plants

Flue Gas CleaningPower Plants

DesulphurisationWet - FGD

Seawater - FGDCFB - FGD

Ammonia - FGD

DenitrificationSCR - Technology

Treatment Plantsfor Industrial

Waste/ResiduesSewage Sludge

Rotary Kiln

Fluidised Bed

Flue Gas Cleaning

Biomass to EnergyPlants

Circulating FluidisedBed

Grate Systems

Flue Gas Cleaning

Energy fromWaste Plants

Grate Systems

Circulating FluidisedBed

ROWITEC®

Flue Gas Cleaning

Energy Division Environment Division

Page 12: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

12

Technologies of Energy and Environment Divisions

Energy

CCPP

CFB

Flue Gas Desulphurisation

Environment

Energy-from-Waste and Biomass Plants

Sewage Sludge Incineration

Hazardous Waste Incineration

Page 13: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

13

GAVI Wijster / NL, Water cooled grate3 x 20 t/h

Taoyuan / ROC, Roller Grate2 x 28 t/h

Page 14: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

14

Madrid / E, ROWITEC3 x 9 t/h

Sleco / B, ROWITEC3 x 20,8 t/h

Page 15: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

15

Lenzing / D, CFB110 MWth

Premnitz / D, CFB60 MWth

Page 16: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

16

Ebenhausen / D2 x 50.000 t/a

Bayer AG Dormagen / D45.000 t/a

Page 17: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

17

Dordrecht / NL3 x 12 t/h, 1 x 24 t/h

Crossness / UK2 x 3,5 t/d, 5,2 MWel

Page 18: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

18

SITA Kirklees, Huddersfield / UK1 x 17 t/h

Shell Green, Manchester / UK1 x 5,7 t/d ExtensionTarget Price Contract Award 2005

Page 19: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

19

WRG Allington, Kent / UK3 x 21,4 t/h

Page 20: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

20

Colleferro / I

Wuppertal / D

Budapest / H

Madeira / P

Page 21: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

21

Recent Plant References Energy-from-WasteStart-up Plant Grate System Throughput LHV (kJ/kg) Waste FGC System

2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200 MSW Semi-dry2002 Madeira / P Roller Grate 2 x 192 t/d 7,800 MSW Semi-dry2002 Terni / I Reci. Grate w/c 1 x 300 t/d 15,000 SRF Semi-dry2002 San Vittore / I Reci. Grate w/c 1 x 300 t/d 15,000 SRF Semi-dry2002 Colleferro I+II / I Reci. Grate w/c 2 x 300 t/d 15,000 SRF Semi-dry2002 Premnitz / D CFB 1 x 60 MWth 14,000 SRF Circoclean2003 Powergen / UK FB 1 x 530 t/d 5,200 Paper Sludge Fabric Filter2003 Strongoli / I CFB 2 x 20 MWel 11,100 Biomass Dry (BiCar)2004 Budapest / H Roller Grate 4 x 360 t/d 8,500 MSW Semi-dry2005 Cantabria / E Roller Grate 1 x 288 t/d 11,720 MSW Circoclean

2006 Sleco / B ROWITEC 3 x 495 t/d 8,300 50 % SRF50 % Sludge

Circoclean +Scrubber

2006 Allington / UK ROWITEC 3 x 513 t/d 9,200 MSW Circoclean2006 Frankfurt / D Recipr. Grate 4 x 480 t/d 10,300 MSW Circoclean2008 Casteltermini / I Reci. Grate w/c 2 x 413 t/d 12,560 SRF Dry (BiCar)2008 Augusta / I Reci. Grate w/c 3 x 413 t/d 12,560 SRF Dry (BiCar)2008 Palermo / I Reci. Grate w/c 3 x 552 t/d 11,550 SRF Dry (BiCar)2008 Manchester / UK FB 1 x 140 t/d 12,600 (DS) Sludge Wet multi-stage

Page 22: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

22

Plant References Energy-from-Waste

74 Lines in 43 Plants

equivalent to

1.107 tph or ~8,85 mio tpy

Page 23: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

23

2. Technologies

Page 24: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

24

Lentjes’ Technologies Related to Waste Sector

• Conditioned Dry – CIRCOCLEAN®

• Semi Dry• Wet Scrubbers• SCR and SNCR

Gas Cleaning:

• Horizontal / vertical multi pass systems• Standard WTE parameters preferred

Heat RecoveryBoilers:

• Reciprocating Grate (air/water-cooled)• Roller Grate• Circulating Fluid Bed• ROWITEC® Fluid Bed• Fluidized Bed

Furnace Types:

Page 25: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

25

Roller GrateReciprocating Grate

Counter Reciprocating Grate

Application:

Incinerationof MSW

Application:

Incinerationof MSW / SRF

Grate Systems

Page 26: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

26

Fluidised Bed Systems

ROWITEC® CFB

Application: Application:Incineration of MSW / SRF + Sludge Incineration of SRF

Page 27: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

27

Typical Application Ranges of Technologies

Page 28: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

28

Roller Grate

Page 29: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

29

Roller Grate Section I

Page 30: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

30

Roller Grate Section II

Page 31: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

31

Roller Grate Side Wall

Page 32: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

32

Grate Bar

Page 33: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

33

Roller Grate Drives

Page 34: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

34

Roller Grate Capability for High CV‘s

EfW Plant Wuppertal / DVariation of Heating Values

- Roller Grate -

8.000

9.000

10.000

11.000

12.000

13.000

14.000

15.000

16.000

1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 1819 20 21 2223 24 25 26 27 28 29 3031 32 33 3435 36 37 3839 40 41 4243 44 45 4647 48 49 5051 52

Week

LHV

MJ/

kg

2002 2006 Average 2002 (11,8 MJ/kg) Average 2006 (10,6 MJ/kg)

Page 35: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

35

Combined Grate

Page 36: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

36

Function of Grate Type 410 (Reciprocating)

Start Position Middle Position Final Position

moving rows fixed rows

Page 37: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

37

Start Position Middle Position Final Position

Function of Grate Type 510 (Counter Reciprocating)

fixed rowscounter moving rows

counter moving rows

Page 38: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

38

Center Flow Combustion Chamber

Page 39: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

39

Roller Grate / Reciprocating Grate

Ø Both meet all guarantees (burnout incl. siftings)Ø Both have very good referencesØ Both present modern state-of-the-art designØ Roller Grate has lower energy useØ Roller Grate has less maintenance requirementsØ Significant grate bar weight differenceØ Roller Grate has a higher CV limit in standard formØ Geometry configuration is different (70 % difference

in width has advantages for boiler design)Ø Roller Grate has lower exchange ratesØ Roller Grate applicable for both small and large units

Page 40: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

40

ROWITEC® Fluidized Bed FiringProcess Principle

1. Waste Feeder2. Revolving Fluidised Bed3. Fluidising Air4. Flue Gas5. Deflector Plate6. Non-combustibles

Discharge Chute7. Inclined Nozzle Plate

Page 41: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

41

ROWITEC® Fluidized Bed

Primary airsupply

Non combustiblesdischarge screw

conveyor

Waste Feeder

Secondary airinlet nozzles

2. Screen

Freeboardburner

Flue gasesto boiler

Sandvalve

Bed preheatburner

Bucketelevator1. Screen Magnetic

separator

BedMaterial(sand)

storagesilo

Non combustiblesdischarge conveyor

1 Flue gases to boiler2 Freeboard burner3 Secondary air inlet nozzles4 2. Screen5 Sand valve6 Waste Feeder7 Bed Material (sand storage silo)8 Bed preheat burner9 Primary air supply

10 Non combustibles dischargescrew conveyor

11 1. Screen12 Magnetic separator13 Bucklet elevator14 Non combustibles discharge

conveyor

Page 42: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

42

ROWITEC® Fluidized BedMadrid Integrated Waste Processing Facility

Page 43: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

43

ROWITEC® Fluidized BedMadrid Integrated Waste Processing Facility

Page 44: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

44

ROWITEC® Fluidized BedBed Nozzles and Deflector Plates

Page 45: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

45

ROWITEC® Fluidized BedBootom Ash after Ferrous Metals Separation

Page 46: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

46

ROWITEC® Fluidized BedFerrous Metals separated from Bottom Ash

Page 47: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

47

ROWITEC® Fluidized BedResidues in Botton Ash

Page 48: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

48

ROWITEC® Fluidized Bed Firing

Ø Improved heat transfer through the use of a sand bed.Ø Rapid, complete combustion in the fluidized bed with

a short retention time.Ø High flexibility with regard to variations in the

composition of the refuse.Ø Ease of control due to staged, targeted combustion air

feeding.Ø Reducing atmosphere in the bed zone, therefore

substantially lower NOx levels in the combustor.Ø Complete combustion: the residual carbon content of

the bed ash and fly ash is usually less than 0,1 wt. %.Ø No moving parts in the hot combustor area.

Page 49: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

49

Combustion System / Steam Generator I

Page 50: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

50

Combustion System / Steam Generator II

Page 51: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

51

Combustion System / Steam Generator III

Page 52: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

52

Combustion System / Steam Generator IV

Page 53: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

53

Horizontal / Vertical Boilers

Ø Both meet all guaranteesØ Both have very good referencesØ Both present modern state-of-the-art designØ Horizontal boiler has less steam consumptionØ Vertical boiler results in lower invest costØ Vertical boiler requires higher buildingsØ Horizontal boiler requires more spaceØ General tendency:

Horizontal boilers for small unitsVertical boilers for large units

Page 54: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

54

Flue Gas Treatment Processes

Process TypesFlue Gas Treatment downstream

Waste Incineration Plants

Dry Processes

• NEUTREC• Ca(OH)2 based

processes

Wet Scrubbing

• Spray scrubbers• Packed columes

scrubbers• Multi stage scrubbers• Wet electrostatic

precipitators

Catalytic/Non-CatalyticProcesses

• Activated carbonprocesses

• SCR-DeNOx andDeDiox

• SNCR-denitrification

Process Recovering

• Gypsum recovery• HCl-recovery• Recovery of

NaCl/CaCl2

Semi-Dry Processes

• CIRCOCLEAN• Spray absorbtion• Dry conditioned

processes

Combined Processes

• Effluent free processesby means of evaporationand/or recovery ofvaluables

Adsorption Processes

• Transport reactor• Fixed bed adsorber• CFB

Page 55: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

55

Comparison of Flue Gas Treatment Systems

- High Investment Costs- Limited Removal Efficiency

- High Residue Disposal Costs

- Possibly Waste Water Treatment required- High Residue Production

- High Maintenance and Operational Costs- High Sorbent Consumption

+ Minimised Residue Disposal Costs

+ Minimised Residue Production+ Effluent Free

+ Minimised (Stoichiometric) SorbentConsumption

+ Low Maintenance and Operational Costs

+ High Removal Efficiency+ Low Investment Costs

Wet ProcessesDry / Dry Conditioned Processes

Page 56: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

56

Circoclean® Flue Gas Cleaning System

TICp

LCFIC

Water

Activated Carbon

Flue Gas

Residues CFBReactor

Fabric Filter Stack

ID - Fan

Pressurecombustionchamber

Control

A

Lime

Control

Page 57: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

57

MHKW Frankfurt (Old Plant)

Page 58: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

58

Old Plant New PlantAnnual Capacity t/a 447.000 525.000

Number of Lines 4 4

Capacity per Line t/h 15 20

LHV @ MCR MJ/kg 9,2 10,3 (8,0 – 14,0)

Steam Parameter °C/bar 500/60 500/60

Boiler Design 3-Pass + Horiz. 1-Pass + Horizontal

Flue Gas Cleaning System Semidry, ESP, Cond. dry CircocleanFabric Filter with PAC

Emission Values 17. BImSchV 17. BImSchV

MHKW FrankfurtComparison of Design Data

Page 59: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

59

MHKW FrankfurtTypical Operation Data (mg/mn³)

Raw gas Clean gas Ø

HCl 600 – 750 7,5SO2 160 – 270 8,4

CO 8,6Cges 0,5NOx 180

Hg 0,002

Dust 0,5

Page 60: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

60

MHKW FrankfurtImpressions during the Erection I

Page 61: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

61

MHKW FrankfurtImpressions during the Erection II

Page 62: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

62

MHKW FrankfurtImpressions during the Erection III

Page 63: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

63

MHKW Frankfurt(New Plant)

Page 64: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

64

Taoyuan SouthPlant Location

Taoyuan SouthPlant Location

Page 65: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

65

Technical Data

Service Area 25 km Radius, Southern Taoyuan County (nearInternational Airport), 950.000 Inhabitants

Municipal / Commercial Waste 420.000 t/aWaste Bunker Volume 12.000m³Waste Pre-treatment System noneIncineration 2 x 28,125 t/hGrate Type Roller GrateHeating Value Waste 5,9 – 13,4 MJ/kg (9,6)Incineration Temperature 1100°CSteam Generation per Boiler 85 t/h, 40 bar, 400°CPower Generation 40 MWe, 4 MWth District HeatFlue Gas Cleaning System 2 x 160.000 m³/h, Spray Dryer (Semi-dry) with

Baghouse, Provisions for SNCREmission Limits Acc. to Taiwan EPALand Required 200 m x 175 m

Page 66: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

66

Taoyuan SouthFlow Diagram

1. Waste Tipping2. Incinerator with

Steam Generator3. Deslagging4. Spray Absorber5. Bag Filter6. Residue Silos7. Cement Silo8. Solidification9. Turbo Generator Set

and Water / Steam -Cycle

Page 67: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

67

BOILER HOUSE BUNKER TIPPING HALL

AIR COOLED CONDENSER TURBINE HOUSE

STACK

FLUE GAS CLEANING

RR

Q

P

1 2 3 4

N

M

L

K

J

5 6 7 8 9 10 11 12

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12

13 14 15 16 1817 19 20 21 22 23 24

R

Q

P

N

M

L

K

J

13 14 15 16 1817 19

H

G

F

E

D

20 21 22 23

C

B

A

24

Taoyuan Southern Region BOO Municipal Solid Waste Incineration Plant

8

7

6

5

4

10

2

1

9

3

12345678910 Air Cooled Condenser

Steam Turbine Generator Set

Bag FilterSemi Dry ScrubberWaste Heat Recovery BoilerIncineratorRefuse CraneRefuse Bunker

I.D. FanStack

Taoyuan SouthSectional View

Page 68: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

68

Plant Model

Page 69: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

69

Plant Impressions

Page 70: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

70

Plant Impressions

Page 71: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

71

Plant Impressions

Page 72: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

72

Plant Impressions

Page 73: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

73

Taoyuan SouthOperation Data

38436,46200303 680 744

Total 2096 39673,39 2159

200302 672 19461,47 672

Year / Month#1 Incinerator #2 Incinerator

200301 744 20211,92 743Operation hour Treatment tonnage Operation hour Treatment tonnage

19615,7418820,72

18450,36210927,76

19419,118639,4111646,4812154,78

12558,5319472,6920261,0620941,95

4565567747999

21143,3718491,61672

643 17748,42

16812,7618965,85215293,76

744

482744720744744720

8030

18720,4921048,2912275,2819431,8119021,6121378,9

20061,2918514,167916,25

720299720744

Total

21147,07744672744456744699744744

200209200210200211200212

200205200206200207200208

200201200202200203200204

#1 Incinerator #2 IncineratorYear / Month

Operation hour Treatment tonnage Operation hour Treatment tonnage

Page 74: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

74

3. Summary

Page 75: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

75

Lithuania Projects

Ø Lithuania EfW facilities will require

l Large Contractor with Parent CompanyBacking

l Long Term Commitment to European EfWMarket

l Robust Guarantees

l Bankability

ü

ü

ü

ü

Page 76: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

76

Lithuania Projects

Ø Lentjes provides …

l Type and range of technologies

l Ability to meet capacity range

l Experience and references in PL

ü

ü

ü

Page 77: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

77

High level technologies for the incineration of waste are availableand allow economic and efficient disposal concepts.

All technologies fulfil the requirements forü large unitsü high efficiency

A decision for a system must be taken on a project specific basis!

The aim must remain:

Environmentally safe and reliable incineration of waste.

Summary

Page 78: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

78

Lentjes GmbH Forward Market Philosophy

Ø Build on sustained presence in key WTE markets

Ø Select target projects technically and commercially

Ø Maintain turnkey capability

Ø Longterm WTE experience with multiple references

Ø Continue to offer proven technology

Ø Maintain Lentjes’ reputation for quality process plants

Ø Increase market share in Waste to Energy markets

Page 79: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

79

Win-Win-Position

Lentjes GmbH

TurnkeyContractor

Strong MarketPresence

In House Chute toStack Technologies

Bankability

Lithuania

Requires waste managementsolutions incorporating

steam/power experts

Page 80: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

80

… is the worldwide experienced EPC GeneralContractor with proprietary technical solutions forsolid and liquid, hazardous and non-hazardouswaste incineration plants.

Lentjes GmbH

Page 81: Presentation of Waste incineration technologies from ... · 2001 Taoyuan South / ROC Roller Grate 2 x 675 t/d 9,600 MSW Semi-dry 2002 Kirklees / UK Recipr. Grate 1 x 410 t/d 9,200

81

Thank you for your attention!

Gunnar LischkeSales DirectorLentjes

We have TechnologiesWe have Know-howWe have References