Precise Glove Box Overview Presentation
-
Upload
labconco-corporation -
Category
Health & Medicine
-
view
1.756 -
download
0
description
Transcript of Precise Glove Box Overview Presentation
Labconco Precise™ Glove Boxes
Basic
Controlled Atmosphere
HEPA-Filtered
XPert® Weigh Box
Product Overview
The material included in this presentation is copyright of Labconco Corporation.
Reproduction or use of the slides is not permitted without express permission from
Labconco Corporation.
COPYRIGHT NOTICE
Glove Boxes provide a total physical barrier to the internal work area. Depending on the type of glove box, the physical barrier may:
Protect sensitive material inside from the outside contamination (chemicals or particulates)
Protect operators from hazards inside (chemicals or particulates)
Or both
What are Glove Boxes?
Labconco Precise™ Glove Boxes
Controlled Atmosphere Glove Boxes Creates an inert gas atmosphere
Oxygen and moisture levels are reduced
Using compressed Nitrogen or Argon, O2/H20 levels can be reduced to a specific level (ex. 1% or 0.0001%) Example application-high-purity metals and anhydrous chemicals
Types of Precise Glove Boxes, which to choose?
Labconco Precise™ Glove Boxes
HEPA Filtered Glove Boxes
Main chamber air volume is vented like a fume hood
All air entering and leaving is HEPA filtered (Air chemistry is not controlled) Example Application-Potent/toxic drug compounds
One-piece molded, polyethylene shell
Laminated safety glass window, removable for loading
equipment
Inner and outer transfer chamber doors, pivot upward
Black, chemical resistant work surface
Ceiling-mounted electrical duplex outlet
(115 volt 5 amps)
13 cubic feet of interior space
Transfer chamber11.0" ID x 12.0″
No leaks greater than 1 x 10-3 ml/sec, while pressurized with helium at 5” inches of water gauge
22 watt Fluorescent lamp
Transfer chamber shelf
Neoprene gloves, 0.15" thick, 30" long, size 9 3/4
ETL,UL and CE listed
Precise™ Glove Boxes - Standard Features
Labconco Precise™ Glove Boxes
Precise Base Stand with Casters #5235500
Precise Base Stand w/o Casters #5235501
Precise Basic Glove Box #5220000 Sealed chambers, no valves
Precise Controlled Atmosphere Glove Box #5220100 Sealed chambers, with valves
Precise HEPA-Filtered Glove Box #5220200 Blower ventilated chamber with HEPA Filters
XPert Weigh Box #5220300 Blower ventilated chamber with HEPA Filters
with anti-vibration, anti-static accessories included
Precise™ Glove Box models and part #
Labconco Precise™ Glove Boxes
Basic Isolation Chamber
Laminated safety glass viewing window ¼" thick
Space-saving inner and outer transfer chamber doors
Black, chemical-resistant phenonlic core work surface
Interior ceiling-mounted electrical duplex receptacle
Neoprene gloves
Exterior fluorescent lamp
13 cubic feet of interior space
Precise™ Basic Glove Boxes
Labconco Precise™ Glove Boxes
Precise™ Controlled Atmosphere Glove Boxes
Maintain inert gas atmospheres, using pressurized nitrogen or argon gas
Protect air-sensitive materials, i.e. inorganics, organics, biochemicals, organometallics
Reduces or eliminates chemical reactions with oxygen and moisture contamination
Labconco Precise™ Glove Boxes
Entry level controlled atmosphere box
Can be accessorized to full electronic control levels
1% to 0.0050% or 10,000 to 50 ppm O2/H2O
Options include O2/H2O removal and monitoring systems
Precise™ Controlled Atmosphere
Labconco Precise™ Glove Boxes
Glove Box Inlet Connection
Glove Box Outlet Connection
Transfer Chamber Inlet Connection
The transfer chamber is evacuated and refilled to zero pressure, with inert gas-this removes O2/H20 contaminants
The main chamber is evacuated and pressurized with inert gas repeatedly- this removes O2/H20 contaminants
Precise™ Controlled Atmosphere Connections
Labconco Precise™ Glove Boxes
Transfer Chamber Outlet Connection
Provides a physical barrier, protecting the operator or the product materials inside from exposure to dangerous particulates (ex. Hazardous solids vs. Clean Room applications)
Inlet air is HEPA filtered, creating an ISO Class 5 or Class 100 environment
Exhaust air is HEPA filtered removing particulates
HEPA = High Efficiency Particulate Air
Air cleanliness standards:
Class 100 = 100 or less, particles at ≥ 0.5 um per cubic foot.
ISO Class 5 Standard = 3,520 or less, particles at ≥ 0.5 um per cubic meter.
Precise™ HEPA-Filtered Glove Boxes
Labconco Precise™ Glove Boxes
HEPA-filtered glove box - positive or negative pressure operation
Reduces chemical hazard risk levels
Ultra Clean Room application (positive pressure)
Superior filtered containment, tested to ISO #3 clean room standard
Built-in blower capable of 13 to 100 CFM
Precise™ HEPA-Filtered Glove Boxes
Labconco Precise™ Glove Boxes
Superior filtered containment - tested to ISO #3 clean room standard
Anti-static ionizer fan to reduce static charge
Balance vibration isolator consisting of marble slab with isolator pads
Vibration less than 1.5 x 10-5 inches displacement measured at the work surface
Built-in blower capable of 13 to 100 CFM
Ultra Clean Room applications (positive pressure)
XPert® Weigh Box Glove Box
Labconco Precise™ Glove Boxes
Precise HEPA/XPert Air Filtration Systems
HEPA intake filter
Exhaust HEPA filter
Blower
Accessory Recirculation kit
Blower speed controller provides adjustable air flow volumes (CFM = cubic feet per minute).
Internal particulate levels reduced by dilution with HEPA filtered air, overtime. Dilution Rate = air flow volume ÷ chamber volume
Labconco Precise™ Glove Boxes
Internal Main Chamber Dims: 34.5" w x 28.2" d x 25.7" h
Internal Transfer Chamber Dims: 11.25" dia x 12.7" L
Precise™ Glove Boxes Size
Labconco Precise™ Glove Boxes
Anti-static ionizer
Balance vibration kit
Drain and drain valve
Electrical outlet strips
RS 232 data port pass
Polycarbonate window
Airflow monitor
Storage shelves
IV bar kit
Glove port covers
Exhaust ductwork connection kit
Recirculation kit
Positive pressure kit
Over 70 accessories to customize to your applications
Labconco Precise™ Glove Boxes
Oxygen/Moisture Trap
Oxygen/Moisture Stand
Circulating Pump
Automatic Pressure Controller
Tubing Connection Kits
Rotary Vane Vacuum Pump
Precise™ Controlled Atmosphere Glove Box accessories
Labconco Precise™ Glove Boxes
Labconco Corporation 8811 Prospect Ave.
Kansas City, MO 64132
1-800-821-5525 816-333-8811
www.labconco.com