Pond and Wetland BMPs, Retrofitting Detention Basins

Page 2: Pond and Wetland BMPs, Retrofitting Detention Basins

WET PONDS

Page 3: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 4: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond Treatment Processes

• Settling

• Plant Uptake and Adsorption

• Infiltration

• Evaporation

Page 5: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Ponds - Criteria

• Provide Quantity and Quality Control(not volume control)

• Drainage Area: Minimum of 10 Acres (>25 Acres Preferred)

• Treat Water Quality Volume• Retrofit Opportunities• Maintenance

sediment removal

Inlet & outlet

vegetation

Page 6: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Ponds – Primary Design Parameters

• Storage VolumeChannel Protection & Flood Control

• Detention Time (24-48 Hours)Water Quality

• Release RateChannel Protection & Flood Control

Page 7: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond – Other Design Criteria

• Treat Up to 75 Acres

• Include Forebay

• Depth: 4-6 Feet

• Geometry Affects Performancedead storage

short circuiting

Page 8: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 9: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 10: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 11: Pond and Wetland BMPs, Retrofitting Detention Basins

Extended Detention Pond

Page 12: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond

Page 13: Pond and Wetland BMPs, Retrofitting Detention Basins

Multiple Pond System

Page 14: Pond and Wetland BMPs, Retrofitting Detention Basins

Pocket Pond

Page 15: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond – Hydraulic Design

• Design Pond Using Acceptable Methodology– NRCS…TR55…TR20– Penn State Runoff Model (PSRM)– Modified Rational Method– Other

• Hydrograph Routing Is Necessary

Page 16: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 17: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond – Area Ratio

Area Ratio = Drainage Area

Pond Area

Should Be Less Than 100

For Maximum Efficiency

Page 18: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Ponds – Pollutant Removal

Sediment………….. 50-90%

Total Phosphorus… 30-90%

Soluble Nutrients….40-80%

Lead……………….. 70-80%

Zinc…………………40-50%

Page 19: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 20: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 21: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 22: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 23: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 24: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 25: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 26: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond Criteria

1. Minimum Contributory Area: 10 Acres2. Pretreatment: Sediment Forebay

Sized to Contain 0.1 inches per impervious area

3. Design to Treat Water Quality Volume4. Multiple Treatment Pathways Increase

Performance…Multiple Cells…Pond-Wetland Train

Page 27: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond Criteria

5. Pond Benches

A. Safety Bench – 6%Maximum Slope

B. Aquatic Bench – Maximum Depth 18” Below Normal Pool

6. Provide for Maintenance Access

Page 28: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 29: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 30: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 31: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 32: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 33: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 34: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 35: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 36: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 37: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 38: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 39: Pond and Wetland BMPs, Retrofitting Detention Basins

Types of Wetlands

• Shallow Wetland

• Extended Detention Wetland

• Pond-Wetland System

• Pocket Wetland

Page 40: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 41: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 42: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 43: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 44: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 45: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 46: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 47: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 48: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 49: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 50: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 51: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 52: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 53: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 54: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 55: Pond and Wetland BMPs, Retrofitting Detention Basins

Component Design

Outlet Structure

Page 56: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 57: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 58: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 59: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 60: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 61: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 62: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 63: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 64: Pond and Wetland BMPs, Retrofitting Detention Basins

Wetland Treatment Criteria

1. Surface Area: At least 1% of total Drainage Area

2. 25% of WQv Should Be In Deep Water Zones (4’)

3. Minimum of 35% of Area: Depth of 6” or less

4. At least 65% of Area: Shallower than 18”

Page 65: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 66: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 67: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 68: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 69: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 70: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 71: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 72: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 73: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 74: Pond and Wetland BMPs, Retrofitting Detention Basins

Existing Conditions – (Pre-Construction)

Page 75: Pond and Wetland BMPs, Retrofitting Detention Basins

Proposed Conditions (Post-construction)

Page 76: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 77: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 78: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 79: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 80: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 81: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 82: Pond and Wetland BMPs, Retrofitting Detention Basins

Proposed Conditions (Post-construction)

Page 83: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 84: Pond and Wetland BMPs, Retrofitting Detention Basins

Retrofitting Detention Basins

Page 85: Pond and Wetland BMPs, Retrofitting Detention Basins

Conventional Detention Basins

• Designed For Flood Control & Channel Protection

large storm events (50 year…100 year)

• Do Not Control: runoff volumewater quality

• Do Not Provideaestheticswildlife habitat

Page 86: Pond and Wetland BMPs, Retrofitting Detention Basins

Retrofitting Detention Basins - Benefits

• Pollutant Removal

• Water Quality Improvement

• Wildlife Habitat Creation

• Aesthetic Improvement

• Reduced Maintenance

Page 87: Pond and Wetland BMPs, Retrofitting Detention Basins

Retrofitting Detention Basins - Modifications

• Modify Outfall Structurecreate two-stage release

treat small storms for water quality

• Eliminate Paved Low-Flow Channelsuse meandering vegetated swales

increase detention time for small storms

Page 88: Pond and Wetland BMPs, Retrofitting Detention Basins

Retrofitting Detention Basins - Modificatons

• Use Stilling and Settling Basins at Inlets & Outlets

remove sediment & attached pollutantsplant with wetland plants

• Regrade to Provide Micro-Habitats

• Create Wetland - Pond Areas

Page 89: Pond and Wetland BMPs, Retrofitting Detention Basins

Extended Detention Basin Conversion

Page 90: Pond and Wetland BMPs, Retrofitting Detention Basins

Wet Pond Conversion

Page 91: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 92: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 93: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 94: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 95: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 96: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 97: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 98: Pond and Wetland BMPs, Retrofitting Detention Basins
Page 99: Pond and Wetland BMPs, Retrofitting Detention Basins

Proposed Conditions – Post Construction Construction

Page 100: Pond and Wetland BMPs, Retrofitting Detention Basins