Polyacrylamide gel electrophoresis (PAGE)

11
Polyacrylamide gel electrophoresis (PAGE) Electrophoresis in a polyacrylamide matrix separating or resolving molecules in a mixture under the influence of an applied electric field •PAGE used for proteins and small pieces of DNA •Similar idea to separation of DNA in agarose •2 major determinants of particle mobility are charge/mass ratio and structure •Polyacrylamide has smaller pore size- better resolution (2bp differences in DNA) and separates smaller molecules (50-500bp) •One bp has molecular mass of 660 Daltons (Dalton=gm/mole) •1 kb piece of DNA = 660kDa •Average protein has mass of ~ 60kDa.

description

Polyacrylamide gel electrophoresis (PAGE) Electrophoresis in a polyacrylamide matrix separating or resolving molecules in a mixture under the influence of an applied electric field PAGE used for proteins and small pieces of DNA Similar idea to separation of DNA in agarose - PowerPoint PPT Presentation

Transcript of Polyacrylamide gel electrophoresis (PAGE)

Page 1: Polyacrylamide gel electrophoresis (PAGE)

Polyacrylamide gel electrophoresis (PAGE)Electrophoresis in a polyacrylamide matrix separating or resolving molecules in a mixture under the influence of an applied electric field•PAGE used for proteins and small pieces of DNA

•Similar idea to separation of DNA in agarose

•2 major determinants of particle mobility are charge/mass ratio and structure

•Polyacrylamide has smaller pore size- better resolution (2bp differences in DNA) and

separates smaller molecules (50-500bp)

•One bp has molecular mass of 660 Daltons (Dalton=gm/mole)

•1 kb piece of DNA = 660kDa

•Average protein has mass of ~ 60kDa.

•PAGE used for proteins and small pieces of DNA

•Acylamide is synthesized (not natural like agarose)

Page 2: Polyacrylamide gel electrophoresis (PAGE)

• A typical setup consists of a gel slab sandwiched between two glass plates, with the ends enclosed in upper and lower reservoirs of buffer

• Samples to be run are loaded in wells at the top of the gel, in conjunction with tracking dye. An electrical voltage is applied between the upper and lower reservoirs, causing the samples to migrate down through the gel.

Page 3: Polyacrylamide gel electrophoresis (PAGE)

• Once a gel has been 'run', it is treated to reveal the positions of the samples

Staining • Coomassie blue-sensitive to 0.1ug of protein• Silver- sensitive to 0.002ug of protein, based on ppt of silver ions

producing brown stain, laborious.• greater sensitivity, radioactive samples can be used, allowing for

exposure over time to produce images on photographic film, as seen in the sequencing gel on the right

• To calibrate the relative migrations of molecules of different size, a marker lane is often added, where samples of known size will migrate to reference positions

Page 4: Polyacrylamide gel electrophoresis (PAGE)

4 components of gel 1. Acrylamide2. APS3. TEMED4. Bisacrylamide

• Acrylamide forms long polymer chains• Polymerization induced by APS (ammonium persulphate) which

generates free radicals (charged oxygens)• TEMED is a free radical stabilizer (N’N’N’N’-tetra methylene

diamine)• Air inhibits polymerization as it scavenges free radicals• Bis acrylamide is a cross linking agent and links long polymers of

acrylamide (N, N’-methylene bisacrylamide)• Pore size is determined by % acrylamide and the amount of cross

linker• The copolymerization of acrylamide with methylenebisacrylamide

produces a mesh-like network in three dimensions, consisting of acrylamide chains with interconnections formed from the methylenebisacrylamide

Page 5: Polyacrylamide gel electrophoresis (PAGE)
Page 6: Polyacrylamide gel electrophoresis (PAGE)

SDS PAGE• SDS is used in the gel mix.• SDS is –ve charged and binds to proteins,

it denatures (unfolds) proteins and gives a net negative charge.

• Proteins will then migrate to the anode• Proteins all have same charge to mass

ratio• Can be separated based on size alone

Page 7: Polyacrylamide gel electrophoresis (PAGE)

Native PAGE

• No denaturing agents

• Proteins separated based on size charge and shape.

• Used when want to keep protein active to study conformation, self-association or aggregation, and the binding of other proteins

Page 8: Polyacrylamide gel electrophoresis (PAGE)

Discontinuous versus Continuous1. Discontinuous

– Common– Better resolution– Stacker-used to stack proteins into thin band so have same

starting position when enter separating gel. Proteins gel squished between “leading” and “trailing” ions in the gels make with different buffers

– Resolving gel- higher % used to separate proteins, a pH change makes ions from the stacking gel move past the proteins and the proteins are no longer squished.

2. Continuous• no stacker, poor resolution, big blobs• easier to pour• Faster to run

Page 9: Polyacrylamide gel electrophoresis (PAGE)

Potential problems with Polyacrylamide gels– Underloaded (bands invisible)– Sloppy loading or to little concentration of protein – Bent bands– Tearing– frowning

• Cleanliness is next to godliness when making gels

Page 10: Polyacrylamide gel electrophoresis (PAGE)
Page 11: Polyacrylamide gel electrophoresis (PAGE)

1. Over loaded

2. Tearing

3. Frowning (run too hot)

4. Bent bands. Tearing

5. Sloppy loading or too low conc.