Pdt-cs-10 Ch04 en p320 El p8

23
P320 EL 4 C P8 Software package September 2009 September 2009

Transcript of Pdt-cs-10 Ch04 en p320 El p8

Page 1: Pdt-cs-10 Ch04 en p320 El p8

P320 EL 4 C

P8 Software package

September 2009September 2009

Page 2: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 2 / 23

ALSPA 8000 - P320 EL

P8 SOFTWARE

PACKAGE

P8 SOFTWARE

PACKAGE

Displays browser

Page 3: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 3 / 23

P320 EL

P8 SOFTWARE

– Progiciel P8 Version > 9.01

– PC et CPU protocol SNP, Serial Network Protocol for ALSPA 8000 PLC serial

– Power supply port in RS 422

Page 4: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 4 / 23

P320 EL

P8 SOFTWARE

– MAIN MENU

• CONTROLLER SELECTION :

� SHIFT - F1 ... ALSPA C80-05

� SHIFT - F2 ... ALSPA C80-25

� SHIFT - F3 ... ALSPA C80-35

� SHIFT - F5 ... ALSPA C80-75

• SELECTION OF FUNCTIONALITIES :

� F1 … ALSPA P8 PROGRAMMMING SOFTWARE

� F2 … ALSPA P8 CONFIGURATION SOFTWARE

� F3 ... PCM DEVELOPMENT SOFTWARE (PCOP)

� F4 ... AXIS MODULE DEVELOPMENT SOFTWARE

� F5 ... OPERATOR INTERFACE UTILITIES

� F7 ... ALSPA P8 UTILITIES

� F8 ... USER MENU

� F9 … ALSPA P8 GENERAL PARAMETERIZATION

� F10 ... RETURN TO DOS

Page 5: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 5 / 23

P320 EL

P8 SOFTWARE

�Main Short Cut Keys For P8 :

– ALT-H Interactive on line HELP, "escape" to exit

– ALT-K List of short cut keys "ESCAPE" to exit

– ALT-M To create or to break the communication between PC and plc

monitor / online / offline/ ...

– ALT-R If the link between pc and plc is "on line", ALT R stop or run the plc.

Page 6: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 6 / 23

AFTER SELECTION OF "CONFIGURATION SOFTWARE..." IN THE MAIN MENU USING F2

F1 F2 F3 F7 F8 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓

INPUT/ OUTPUT

CONFIGURATION

CPU

CONFIGURATION

PLC

TESTING

AND

STATUS

SETTING

OF

CONSOLE

PARAMETERS

PROGRAM

FOLDERS

UTILITIES :

TRANSFERS,

DELETING

PRINTING

FUNCTIONS

PASSWORD

IF A CPU CONFIGURATION WAS PREVIOUSLY COMPLETED, PASSWORD DISABLED :

- THE MEMORY OF THE PROGRAMMABLE CONTROLLER MUST BE DELETED AND THE BATTERY

REMOVED FOR MORE THAN AN HOUR TO RECONFIGURE "PASSWORD : ENABLED" AND ENTER

THE DIFFERENT LEVELS.

P320 ELP8 CONFIGURATION SOFTWARE

Page 7: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 7 / 23

AFTER SELECTING "INPUT/ OUTPUT CONFIGURATION" USING F3

⇑⇑⇑⇑ F1 ⇑⇑⇑⇑ F2 ⇑⇑⇑⇑ F3 ⇑⇑⇑⇑ F4 ⇑⇑⇑⇑ F5

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓RACK COPY I/ O VIEW DELETE RECOVER

NO ACTION IN

THIS VERSION

GO TO A

CONFIGURED

MODULE AND

MOVE TOWARDS

THE POSITION TO

WHICH IT IS TO

BE COPIED. THEN

PRESS TO

CONFIRM

SHOWS

THE HIGHEST

VALUE

CONFIGURED

ACCORDING TO

THE LOCATIONS

TO DELETE

A

MODULE

TO

RECOVER

A MODULE

JUST DELETED

F1 F2 F4 F5 F6 F8 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ES N80 PWR S RCKSEL COMM OTHERS ZOOM

SELECTION

OF TYPE OF

MODULE (I/ O,

DISCRETE,

ANALOG) WITH

DISPLAY OF LISTS

SELECT

DES MODULES

N80 OR NBC

WITH DISPLAY OF

LISTS

SEE ZOOM

ON

PWR SUPPLY

MODULE

DISPLAY OF LIST

OF AVAILABLE

BASE PLATES OR

RACKS

DISPONIBLES

SELECT

ETHERNET

OR CMM311

MODULES

SELECT

OF MODULES

PCM, HSC,

EXTERN, ADC,

APM, IOLINK

AND IOP, WITH

DISPLAY OF

LISTS

GO TO POSITION

OF A MODULE

ALREADY

CONFIGURED,

SEEN FROM ITS

DETAILED

CONFIGURATION

P320 ELP8 CONFIGURATION SOFTWARE

Page 8: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 8 / 23

AFTER SELECTING "CONFIGURATION CPU" USING F2

FOR ALL KEYS THE ACTIONS ARE THE SAME AS FOR THE FIRST CONFIGURATION SCREEN ⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10

F1 F3 F4

↓↓↓↓ ↓↓↓↓ ↓↓↓↓

TIME IDSNP LIMIT

SET CONTROLLER TIME

IDENTIFICATION OF CONTROLLER BY A

NAME, ESPECIALLY USEFUL WHEN

USING A P8 CONNECTED TO SEVERAL

C80-35s AND WITH INTER-PLC SNP

COMMUNICATION

DISPLAYS CONFIGURED DATA AND PLC

MEMORY LIMITS

P320 ELP8 CONFIGURATION SOFTWARE

Page 9: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 9 / 23

P320 ELP8 CONFIGURATION SOFTWARE

AFTER SELECTING "CONTROLLER CHECK AND STATUS" USING F3

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F4 F5

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓RUN PLC PASSWORD PLC FLTS ES FLTS PLC MEM

CHOICE OF RUN OR STOP

WITH OR WITHOUT I/ O

SCANNING

4 PASSWORD LEVELS

IF ENABLED IN CPU

CONFIG.

DISPLAYS TABLE

OF PLC FAULTS

DISPLAYS TABLE OF

FAULTS ON MODULE

(HARDWARE)

GIVES AMOUNT OF

PROGRAM MEMORY USED

AND REMAINING

Page 10: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 10 / 23

AFTER SELECTING "CONSOLE PARAMETERIZATION" USING F7

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3

↓↓↓↓ ↓↓↓↓ ↓↓↓↓MODE CONNEC PLC COM

SAME COMMAND AS SELECTION SNP

CONNECTIONS WITH CHOICE

SETTING OF PARAMETERS OF

THE CONSOLE

ALT M OF PLC IDENTIFIER NAME TO COMMUNICATION PORT

FOR

OFFLINE/ MONITOR/ ONLINE

MODE CHANGE

BE PROGRAMMED

1 PC WITH P8 CAN BE

CONNECTED TO 8 PLCs ALSPA

C80-35 WITH DIFFERENT

SNP- ID, IF THE "PORT

CONNECTION" SELECTED

IS : MULTIPOINTS

A TABLE SHOWS ALL THE SNP

ID NAMES

CONNECTED TO

THE ALSPA C80-35

P320 ELP8 CONFIGURATION SOFTWARE

Page 11: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 11 / 23

AFTER SELECTING "PROGRAM FOLDERS" USING F8

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F4 F5 F7 F8

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓

SELECT DELETE AUTO SAVE RESTORE ERASE LOCK

CREATION

A NEW PROGRAM

FOLDER

OR SELECTION FROM

LIST OF THOSE

ALREADY CREATED

DELETES A FOLDER

FROM THE LIST BUT

CANNOT DELETE THE

FOLDER BEING

WORKED ON, CALLED

THE:

"CURRENT FOLDER "

AUTO-SELECTION

FROM LIST OF FOLDER

CORRESPONDING TO

THE ONE LOADED INTO

THE CONTROLLER

(AFTER SELECTING

WITH F1)

SAVES THE CURRENT

FOLDER ON THE HARD

DISK OR ON THE

DISKETTE WITH THE

APPROPRIATE PATH

A:\FOLDER NAME

RESTORAL IN THE

CURRENT FOLDER

FROM THE BACKUP OF

THE HARD DISK OR

DISKETTE A:\FOLDER

NAME

ERASES THE CONTENTS

OF THE CURRENT

PROGRAM FILE

WITHOUT ERASING

THE NAME

LOCKS OR UNLOCKS

THE CURRENT

PROGRAM FOLDER TO

PREVENT CERTAIN

PRECEDING

OPERATIONS

P320 ELP8 CONFIGURATION SOFTWARE

Page 12: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 12 / 23

AFTER SELECTING "UTILITIES : TRANSFERS, ERASE" USING F9

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F5 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓

→→→→ CON →→→→ PLC CHECK ERASE PROM

TRANSFERS

THE

CONFIGURATION

FROM THE PLC TO

THE CONSOLE IN

"RUN" OR "STOP"

MODE

TRANSFERS THE

CONFIGURATION

FROM THE CONSOLE

TO THE PLC

THE PLC MUST BE IN

:

"STOP" MODE

AND

"ON LINE"

BETWEEN

PLC AND CONSOLE

COMPARISON

BETWEEN THE

CONFIGURATION

CREATED IN THE

CONSOLE AND THE

ONE EXISTING IN

THE PLC

ERASES FROM THE

CONTROLLER

MEMORY WITH THE

SELECTION OF

ERASE :

- PROGRAM

- CONFIGURATION

- REFERENCE TABLE

- FORCING TABLE

USED TO READ OR

WRITE OR CHECK

BETWEEN EEPROM

AND RAM

MEMORIES OF THE

PLC

PLC IN STOP MODE

P320 ELP8 CONFIGURATION SOFTWARE

Page 13: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 13 / 23

AFTER SELECTING "PRINTING FUNCTIONS " USING F10

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F4 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓

PARAM SCREEN PRINT PAUSE SAVE

SETTING

PARAMETERS OF

PRINTER

- - NO. OF LINES

PER PAGE

- ETC...

DESTINATION

OF PRINTING

SCREEN :

- PORT

- FILE

CONFIGURATION

OF

PRINT FOLDER

FOR

CONFIGURATION

OF PLC

TO PRINTER OR TO A

FILE

FOR TEMPORARY

STOPPING DURING

PRINTING

SAVING OF

PRINTING

PARAMETERS

CONFIGURED

PREVIOUSLY IN A

PRINT.SET FILE

P320 ELP8 CONFIGURATION SOFTWARE

Page 14: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 14 / 23

AFTER SELECTING "PROGRAMMING SOFTWARE" IN THE MAIN MENU USING F1

F1 F2 F3 F7 F8 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓

TO EDIT

OR TO READ

THE PROGRAM

REFERENCE

TABLES

PLC

TESTING

AND

STATUS

CONSOLE MODE

AND

CONFIGURATION

PROGRAM

FOLDERS

UTILITIES :

TRANSFERS,

ERASE

PRINT

FUNCTIONS

DISPLAYS

VARIABLES

OF DATA MEMORY

BY TYPE WITH

THEIR VALUE

OR THE

PERSONALIZED

TABLES

FROM 1 TO 99

- RUN / STOP

- PASSWORD

- 2 FAULT TABLES

. PLC

. I/ O

- PLC MEMORY

RS-232 PORT N0.

AND ALL ITS

PARAMETERS

CONNECTION

MODE

- WITH 1 PLC

- WITH SEVERAL

PLCs AND SNP ID

- SELECTION

OF

MODES

SEEN BY

PROGRAM

- CREATION

- SELECTION

- DELETION

- SAVE

- RESTITUTION

- ERASE

- LOCKED

- COPY

- ESTABLISHES

THE LINK WITH

THE PLC TO LOAD

OR READ OR

CHECK A FOLDER

- ALLOWS

ERASING OF PLC

MEMORY

- READ, WRITE,

CHECK BETWEEN

RAM AND

EEPROM OF THE

PLC

SETTING

PARAMETERS OF

PRINTER

PRINTING

ALT N THE WHOLE

FOLDER

P320 ELP8 PROGRAMMING SOFTWARE

Page 15: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 15 / 23

AFTER SELECTING … USING F1

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F4 F7 F8 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓INSERT EDIT MODIFY SEARCH OPTION GOTO MORE ZOOM

INSERT

A NEW RUNG

BEFORE THE

CURRENT RUNG

EDIT

THE CURRENT

RUNG

WORD

– FOR –

WORD

EDIT THE

CURRENT RUNG

(TO MODIFY OR

TO REPLACE AN

INSTRUCTION BY

ANOTHER WITH

THE SAME

MEMORY

LENGTH)

SEARCH FOR A

REFERENCE,

NICHNAME OR

INSTRUCTION.

REPLACE THE

FOUND TARGET

WITH THE

REPLACEMENT

ITEM.

DISPLAYS A

SEARCH

CONTROL

WINDOW.

SETUP COIL USE

CHECKING AND

AUTOMATIC

EDITOR OPTIONS.

GOTO A RUNG

OR A BLOCK.

ENTER THE RUNG

NUMBER OR

BLOCK NAME

AND THEN PRESS

"GOTO"

ACCESS FEATURES

FOR EDITING

GROUPS OF

RUNGS, E.G.,

CUT, PESTO

ZOOM INT A

BLOCK,

FUNCTION

BLOCK,

COMMENT, OR

MARKER RUNG

UNDER

P320 ELP8 PROGRAMMING SOFTWARE

Page 16: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 16 / 23

P320 ELP8 PROGRAMMING SOFTWARE

AFTER SELECTING "INSERTION OF A NEW RUNG ...", TO CHOICE AN INSTRUCTION

⇑⇑⇑⇑ F1 ⇑⇑⇑⇑ F2 ⇑ F3 ⇑⇑⇑⇑ F4 ⇑⇑⇑⇑ F5 ⇑⇑⇑⇑ F6 ⇑⇑⇑⇑ F7 ⇑⇑⇑⇑ F8 ⇑⇑⇑⇑ F9 ⇑⇑⇑⇑ F10

RELAY TMPCTR MATH RELATN BIT OP DATAMV TABLES CONVERT CONTRL OPN SP *

-¦ +- TMR ADD EQ AND MOVE SRH EQ BCD - 4 CALL DROITE

-¦/+- OFDT SUB NE OR BLKMOV SRH NE INT DO IO BAS

-( )- ONDTR MUL GT XOR BLKCLR SRH GT PID ISA EFF CO

-(M)- UPCTR DIV GE NOT SHFREG SRH GE PID IND EFF LI

-(/M)- DNCTR MOD LT SHL BITSEQ SRH LT SFCRES EFF SYM

-(S)- TMBASE SQRT LE SHR COMREQ SRH LE END EFF INS

-(R)- RANGE ROL ARR MOV COMMNT

-(SM)- (TIME TYPES : TYPES : ROR TYPES : TYPES : SVCREQ

-(RM)- BASE (INTEGER : INT BITTST WORD . BYTE MCR

(VERT.) 0,1 S INT AND BITSET AND . WORD ENDMCR

0,01 S DOUBLE DINT BITCLR DINT . INT MCRN

(HORIZ.) 0,001 S) INTEGER : BITPOS . DINT ENDMCRN

-(↑↑↑↑)- DINT) MKCOMP JUMP

-(↓↓↓↓)- TYPES : LABEL

<<<<+ >>>>−−−− WORD JUMPN

−−−−<<<<+ >>>> LABELN

* OPEN SPACE : TO ALLOW RUNG MODIFICATIONS

LIS

T O

F I

NS

TR

UC

TIO

NS

AF

TE

R T

HE

AB

OV

E C

HO

ICE

Page 17: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 17 / 23

AFTER SELECTING "EDIT, READ PROGRAM" USING F1

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 THE ACTIONS ARE THE SAME AS FOR THE FIRST PROGRAMMING SCREEN

F1 F2 F3 F4 F7 F8 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓INSER.. EDIT MODIFY SEARCH OPTION TO ... OTHERS ZOOM

INSERTION

OF A NEW

SEGMENT BEFORE

THE POINTED

SEGMENT

EDITION

OF POINTED

SEGMENT.

ALL

MODIFICATIONS

ARE AUTHORIZED

MODIFICATION

OF POINTED

SEGMENT

CERTAIN

CONDITIONS

ARE

OBLIGATORY :

THE SIZE OF THE

INSTRUCTIONS

MUST BE SIMILAR

(SEE CHAPTER

3-12-2 ALS DOC

52201)

SEARCH IN A

PROGRAM FOR

- A REFERENCE

- A MEMONIQUE

- A DESCRIPTION

- AN IDENTIFIER

- AN

INSTRUCTION

REPLACEMENT

AFTER SEARCH BY

DATA OF THE

SAME TYPE

FOR THE EDITOR

- CHECK MULTIPLE

USE OF COILS

- AUTOMATICALLY

INSERT

THE REFERENCES IN

THE VARIABLE

DECLARATION TABLE

(SEGMENT 001)

ALLOWS

DIRECT POINTING

TO A SEGMENT

OR A BLOCK

MANIPULATION

OF SEGMENTS OF

PROGRAMS AND

POSSIBLE CHOICE

BETWEEN

STORAGE TO

BUFFER MEMORY

OR FILES

AFTER

POSITIONING

ON :

- A BLOC

- AN

INSTRUCTION

- A COMMENT

- SEE DETAILS

OF THE

CONFIGURATION

P320 ELP8 PROGRAMMING SOFTWARE

Page 18: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 18 / 23

AFTER SELECTING "REFERENCE TABLES" USING F2

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F2 F3 F5 F6 F7 F8 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓INT DINT HEX BIN ASCII TMCTR MIXTE CHGTOU

CONVERTS

THE POINTED

REFERENCE TO

"SIGNED INTEGER"

VALUE

CONVERTS

THE POINTED

REFERENCE TO

"SIGNED DOUBLE

INTEGER"

VALUE

CONVERTS

THE POINTED

REFERENCE TO

HEXADECIMAL

VALUE

CONVERTS

THE POINTED

REFERENCE

TO BINARY VALUE

(16 BITS)

CONVERTS

THE POINTED

REFERENCE TO

"ASCII

CHARACTER"

CONVERTS

THE POINTED

REFERENCE TO

GROUPS OF 3

CONSECUTIVE

REGISTERS

REPRESENTING A

COUNTER OR A

TIME DELAY

CALLS A

PERSONALIZED

MIXED,

REFERENCE TABLE

(1 TO 99)

INSIDE A TABLE

TO IN ITIALIZE OR

CANCEL FORCING

IN AN ENTIRE

TABLE

P320 ELP8 PROGRAMMING SOFTWARE

Page 19: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 19 / 23

AFTER SELECTING "PLC TESTING AND STATUS" USING F3

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F4 F5 F6 F7 F8

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓RUN MOT PSS DEF AP DEF ES MEM AP MEM BLC TAIL RF CYCLE

IN "ON-LINE"

MODE, ALLOWS THE

CHOICE OF RUN OR

STOP WITH OR

WITHOUT I/ O

SCANNING

4 PASSWORD

LEVELS IF

ENABLED IN THE

CPU

DISPLAYS THE

TABLE OF

CONTROLLER

FAULTS

DISPLAYS THE

TABLE OF FAULTS

ON MODULE

(HARDWARE)

DISPLAYS

PROGRAM

MEMORY

QUANTITIES USED

AND REMAINING

DISPLAYS

DISTRIBUTION OF

MEMORY USED

FOR THE PARTS :

- PROGRAM

- DECLARATION

- COMMENTS

DISPLAYS THE

HIGHEST

ADDRESS USED IN

THE PROGRAM

FOR EACH TYPE

OF VARIABLE

DISPLAYS THE

CYCLE TIME

P320 ELP8 PROGRAMMING SOFTWARE

Page 20: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 20 / 23

AFTER SELECTING "CONSOLE MODE AND CONFIGURATION" USING F7

⇑⇑⇑⇑ F1 TO F10 SAME AS FOR FIRST SCREEN

F2 F3 F4 F5

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓MODE CONNEX CON AP DISPLAY MODE

SAME AS COMMAND SELECTION SNP CONNECTIONS

WITH CHOICE OF PLC

SETTING OF PARAMETERS OF

THE CONSOLE

SELECTION OF DIFFERENT

DISPLAY MODES ON THE

ALT M IDENTIFIER NAME TO BE SNP COMMUNICATION PORT SCREEN OF THE PROGRAM,

FOR

OFFLINE/ MONITOR/ ONLINE

PROGRAMMED 1 PC

WITH P8 CAN BE CONNECTED

TO 8 PLCs ALSPA C80-35

CONNECTED

TO THE ALSPA C80-35

BY PRESSING SUCCESSIVELY

ON :

MODE CHANGE WITH DIFFERENT SNP ID, IF ALT N

THE "PORT CONNECTION"

SELECTED IS : MULTIPOINTS.

A TABLE SHOWS ALL THE SNP

ID NAMES

ALSO SELECTS DIRECTION OF

READING IN TABLE OF

VARIABLES

SAME AS A

ALT N

P320 ELP8 PROGRAMMING SOFTWARE

Page 21: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 21 / 23

AFTER SELECTING "PROGRAM FOLDERS" USING F8

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F4 F5 F6 F7 F8 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓SELECT SUPPRM AUTO SAUVEG RESTIT REN OMM EFFACE VERROU COPY

CREATION

A NEW

PROGRAM

FOLDER

OR SELECTION

FROM LIST OF

THOSE ALREADY

CREATED

DELETES A

FOLDER FROM

THE LIST BUT

CANNOT DELETE

THE FOLDER

BEING WORKED

ON, CALLED

THE :

"CURRENT

FOLDER "

AUTO-

SELECTION

FROM LIST OF

FOLDER SAME

AS THE ONE

LOADED INTO

THE

CONTROLLER

(AFTER

SELECTING

WITH F1)

SAVES THE

CURRENT

FOLDER ON THE

HARD DISK OR

ON THE

DISKETTE WITH

THE

APPROPRIATE

PATH

A:\ FOLDER

NAME

RESTORAL IN

THE CURRENT

FOLDER FROM

THE BACKUP OF

THE HARD DISK

OR DISKETTE

A:\ FOLDER

NAME

USED TO

CHANGE THE

NAME OF THE

CURRENT

FOLDER

ERASES THE

CONTENTS OF

THE CURRENT

PROGRAM FILE

WITHOUT

ERASING THE

NAME

LOCKS OR

UNLOCKS THE

CURRENT

PROGRAM

FOLDER TO

PREVENT

CERTAIN

PRECEDING

OPERATIONS

COPIES THE

CONTENTS OF

ANY FILES INTO

THE CURRENT

FILE MAY BE

DONE FROM A

DISKETTE

P320 ELP8 PROGRAMMING SOFTWARE

Page 22: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 22 / 23

P320 ELP8 PROGRAMMING SOFTWARE

AFTER SELECTIN G "UTILITIES : TRAN SFERS, ERASE" USIN G F9

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F3 F5 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓→→→→ CON →→→→ PLC CHECK ERASE PROM

TRAN SFERTS

A COM PLETE

OR IN COM PLETE

FOLDER FROM PLC

TO THE CON SOLE IN

"RUN " OR "STOP"

M ODE

TRAN SFERTS

A COM PLETE

OR IN COM PLETE

FOLDER FROM

CON SOLE TO THE

PLC IN "ON LIN E"

M ODE

COM PARISON

OF CON TEN TS OF

FOLDER ON HARD

DISKETTE AN D THE

ON E EXISTIN G

IN THE PLC

ERASES FROM THE

PLC M EM ORY, AS

CHOSEN :

- THE PROGRAM

- THE

CON FIGURATION

- THE REFEREN CE

TABLES

- THE FORCIN G

TABLES

USED TO READ,

WRITE OR CHECK

BETWEEN THE

EEPROM AN D RAM

M EM ORIES OF THE

PLC

PLC IN STOP M ODE

Page 23: Pdt-cs-10 Ch04 en p320 El p8

September 2009 PDT-CS-10/P320 EL 4 C Chapter 04 page 23 / 23

AFTER SELECTING "PRINTING FUNCTIONS" USING F10

⇑⇑⇑⇑ F1 TO ⇑⇑⇑⇑ F10 SAME AS FOR FIRST SCREEN

F1 F2 F4 F5 F6 F9 F10

↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓ ↓↓↓↓PARAM SCREEN PROGRM XREF VALUE PAUSE SAVE

SETTING OF PRINTER

PARAMETERS

- PAGE WIDTH

- NUMBER OF LINES

PER PAGE

- ETC…

DESTINATION

OF

PRINTING SCREEN

PORT OR FILE

CONFIGURATION

OF FOLDER FOR

PRINTING TO A

PRINTER OR A FILE

WHEN PRINTING IS

STARTED, MAKES IT

POSSIBLE TO

INSERT THE CROSS

REFERENCES

ACCORDING TO

THE CHOICE OF

SORTING IN THIS

SCREEN

ALLOWS THE

PRINTING OF

VALUES OF

VARIABLES

SPECIFIED IN TABLE

FORM TO THE

PRINTER OR TO A

FILE

ALLOWS A

TEMPORARY STOP

DURING PRINTING

SAVES

PRINTING

PARAMETERS

CONFIGURED

PREVIOUSLY IN A

FILE :

PRINT.SET

P320 ELP8 PROGRAMMING SOFTWARE