Commercial Products Matrix RGS 3 TO 12.5 TONS SUBJECT TO CHANGE WITHOUT NOTICE Shipping Point: Lewisburg, TN. Type of Sale: 6LSS PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009 1 PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10 & 12.5t TONS RGS units are high-efficiency, single-packaged electric cooling, gas heating units that are pre-wired and pre- charged with environmentally sound R-410A HFC refrigerant. The units are factory tested in both heating and cooling modes. Models RGS036-150 Certified to ISO 9001:2000 Sizes 036-060 Size 072-150 STANDARD FEATURES R-410A HFC refrigerant ASHRAE 90.1-2004 compliant 13 SEER efficiency levels Single-stage cooling capacity control on all 036-072 models and the 091,101 and 121 models. Rated in accordance with ARI Standard 210 (036-060 sizes) and 360 (072- 121 sizes) Designed in accordance with Underwriters’ Laboratories Standard 1995 Listed by UL and UL, Canada Energy Star qualified Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain Gas efficiencies up to 82% Induced draft combustion Redundant gas valve, with 1 or 2 stages of heating Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection Acutrol™ refrigerant metering system Fully insulated cabinet Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay “Low NOx” models available that meet California Air Quality Management NOx requirements and include stainless steel heat exchangers Cooling operating range from 25 F up to 115 F using winter start kit, 40 Deg.F Std Access panels with easy grip handles and no-strip screw feature Two-inch disposable return air filters Tool-less filter access door Standard belt drive, constant torque motor Advanced terminal board for simple safety circuit troubleshooting and control box arrangement Convertible from vertical to horizontal airflow for slab mounting Provisions for thru-the-bottom power entry capability Single point gas and electric connections Full perimeter base rail with built-in rigging adapters and fork truck slots Scroll compressors with internal line-break overload protection Copper tube, aluminum fin coils 24-volt control circuit protected with resettable circuit breaker Permanently lubricated evaporator-fan motor Permanently lubricated, totally enclosed, shaft down condenser motors Low pressure, freeze protection, and high pressure switches Exclusive IGC anti-cycle protection for gas heat operation Solid-state electronic direct spark ignition system Flame roll-out safety protector Liquid line filter drier STANDARD WARRANTY 10-year heat exchanger 5-year compressor 1-year parts FACTORY INSTALLED OPTIONS INCLUDE BUT NOT LIMITED TO: Economizer and two position damper options Disconnect and convenience outlet options Multiple optional belt drive motor and pulley combinations Smoke detector and CO2 sensor options Corrosion resistant options for evaporator and condenser coils Optional Stainless Steel Heat Exchanger (S,R,T Models) For a complete list of options and accessories, refer to the Specification Sheets / Catalog for this unit. FORM NO. RGS.1PPG SUPERSEDES New PRICE SECTION RGS (3 to 12.5 Tons)

Transcript of PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4...

Commercial Products Matrix RGS

3 TO 12.5 TONS

SUBJECT TO CHANGE WITHOUT NOTICE Shipping Point: Lewisburg, TN. Type of Sale: 6LSS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

1

PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10 & 12.5t TONS

RGS units are high-efficiency, single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with environmentally sound R-410A HFC refrigerant. The units are factory tested in both heating and cooling modes.

Models RGS036-150

Certified to ISO 9001:2000

Sizes 036-060 Size 072-150

STANDARD FEATURES • R-410A HFC refrigerant • ASHRAE 90.1-2004 compliant 13 SEER efficiency levels • Single-stage cooling capacity control on all 036-072 models and the

091,101 and 121 models. • Rated in accordance with ARI Standard 210 (036-060 sizes) and 360 (072-

121 sizes) • Designed in accordance with Underwriters’ Laboratories Standard 1995 • Listed by UL and UL, Canada • Energy Star qualified • Exclusive non-corrosive composite condensate pan in accordance with

ASHRAE 62 Standard, sloping design; side or center drain • Gas efficiencies up to 82% • Induced draft combustion • Redundant gas valve, with 1 or 2 stages of heating • Pre-painted exterior panels and primer-coated interior panels tested to

500 hours salt spray protection • Acutrol™ refrigerant metering system • Fully insulated cabinet • Exclusive IGC solid-state control for on-board diagnostics with LED error

code designation, burner control logic and energy saving indoor fan motor delay

• “Low NOx” models available that meet California Air Quality Management NOx requirements and include stainless steel heat exchangers

• Cooling operating range from 25 F up to 115 F using winter start kit, 40 Deg.F Std

• Access panels with easy grip handles and no-strip screw feature • Two-inch disposable return air filters • Tool-less filter access door • Standard belt drive, constant torque motor • Advanced terminal board for simple safety circuit troubleshooting and

control box arrangement • Convertible from vertical to horizontal airflow for slab mounting • Provisions for thru-the-bottom power entry capability • Single point gas and electric connections • Full perimeter base rail with built-in rigging adapters and fork truck slots • Scroll compressors with internal line-break overload protection • Copper tube, aluminum fin coils • 24-volt control circuit protected with resettable circuit breaker • Permanently lubricated evaporator-fan motor • Permanently lubricated, totally enclosed, shaft down condenser motors • Low pressure, freeze protection, and high pressure switches • Exclusive IGC anti-cycle protection for gas heat operation • Solid-state electronic direct spark ignition system • Flame roll-out safety protector • Liquid line filter drier STANDARD WARRANTY • 10-year heat exchanger • 5-year compressor • 1-year parts FACTORY INSTALLED OPTIONS INCLUDE BUT NOT LIMITED TO: • Economizer and two position damper options • Disconnect and convenience outlet options • Multiple optional belt drive motor and pulley combinations • Smoke detector and CO2 sensor options • Corrosion resistant options for evaporator and condenser coils • Optional Stainless Steel Heat Exchanger (S,R,T Models) For a complete list of options and accessories, refer to the Specification Sheets / Catalog for this unit.

FORM NO. RGS.1PPG SUPERSEDES New PRICE SECTION RGS (3 to 12.5 Tons)

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

2

SAP CATALOG ORDERING NUMBER NOMENCLATURE

Position No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14Example: R G S 0 7 2 L D A B 0 A A A

R = Rooftop

G = Gas Electric TYPE

S = Standard ASHRAE 90.1-2010 Efficiency EFFICIENCY

036 = 36,000 BTUH = 3 Tons048 = 48,000 BTUH = 4 Tons060 = 60,000 BTUH = 5 Tons072 = 72,000 BTUH = 6 tons090 = 90,000 BTUH = 7.5 tons ( 2 Compressor)091 = 90,000 BTUH = 7.5 tons (Single Compressor)101 = 102,000 BTUH = 8.5 tons (Single Compressor)120 = 120,000 BTUH = 10 tons ( 2 Compressor)121 = 120,000 BTUH = 10 tons (Single Compressor)150 = 150,000 BTUH = 12.5 tons ( 2 Compressor)

NOMINAL COOLING CAPACITY

H = 208/230-3-60K = 208/230-1-60L = 460-3-60S = 575-3-60 VOLTAGE

D = Low HeatE = Medium HeatF = High HeatL = Low Heat, Low NOxM = Medium Heat, Low NOxN = High Heat, Low NOxS = Low Heat, Stainless Steel Heat XgrR = Medium Heat, Stainless Steel Heat XgrT = High Heat, Stainless Steel Heat Xgr

HEATING CAPACITY (See Spec Sheet for Actual Capacity)

A = Standard MotorB = Higher Static Motor MOTOR ( Indoor Fan )

A = NoneB = Economizer w/Bara-relief, OA Temp sensorE = Economizer w/Bara-relief + CO2 Sensor, OA Temp sensorH = Economizer w/Bara-relief, enthalpy sensorL = Economizer w/Bara-relief + CO2 Sensor, enthalpy sensorP = 2-Position damper w/Baro-relief OUTDOOR AIR OPTIONS / CONTROL (See Spec Sheet for Details)

0A = No Options4B = Non-Fused DisconnectAT = Non-powered 115v C.O.BR = Supply Air Smoke Detector7C = Non-Fused Disconnect + Non-Powered 115v C.O.7K = Non-Fused Disconnect + Non-Powered 115v C.O.+ SA Smoke detector8A = Non-Fused Disconnect + SA Smoke detector FACTORY INSTALLED OPTIONS (See Spec Sheet for Details)

A = Aluminum / Copper Cond & Evap CoilB = Precoat Alum/CU Cond II Alum / CU Evap C = E-Coated Alum/Cu Cond II Alum / CU EvapD = E-Coated Alum / Cu Cond & EvapE = Cu / Cu Cond & Alum/Cu EvapF = Copper/Copper Cond & Evap G = Alum / Alum Cond, Alum / Copper Evap Coil CONDENSER / EVAPORATOR COIL CONFIGURATION (See Spec Sheet for Details)

A = Standard PackagingB = Less Than Truckload (LTL) Packaging PACKAGING

SINGLE & 3-PHASE RGS R-410A ROOFTOP PRODUCT MODEL NUMBER IDENTIFICATION GUIDE

LEGEND

SAP – Sales Order Process NOTE: The example model number RGS072LDAB0AAAA designates a 6 ton 460-3-60 volt electric cooling, gas heating rooftop unit with

standard coils and an EconoMi$er IV.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

3

RGS STANDARD UNIT MASTER PRICES SINGLE Compressor Models

SAP CATALOG ORDERING NUMBER

VOLTS-PHASE (60 Hz)

COOLING CAPACITY

(Btuh)

HEATING OUTPUT

(Btuh)

APPROX. SHIP. WT.

(Lbs)

MASTER PRICE

RGS036SDAA0AAA 575-3 34,600 59,040 572 RGS036KDAA0AAA 208/230-1 34,600 59,040 572 RGS036HDAA0AAA 208/230-3 34,600 59,040 572 RGS036LDAA0AAA 460-3 34,600 59,040 572 RGS036SEAA0AAA 575-3 34,600 93,000 572 RGS036KEAA0AAA 208/230-1 34,600 93,000 572 RGS036HEAA0AAA 208/230-3 34,600 93,000 572 RGS036LEAA0AAA 460-3 34,600 93,000 572 RGS048KDAA0AAA 208/230-1 45,000 59,040 582 RGS048HDAA0AAA 208/230-3 45,000 59,040 582 RGS048LDAA0AAA 460-3 45,000 59,040 582 RGS048SEAA0AAA 575-3 45,000 93,000 602 RGS048KEAA0AAA 208/230-1 45,000 93,000 602 RGS048HEAA0AAA 208/230-3 45,000 93,000 602 RGS048LEAA0AAA 460-3 45,000 93,000 602 RGS048SFAA0AAA 575-3 45,000 120,000 610 RGS048KFAA0AAA 208/230-1 45,000 120,000 610 RGS048HFAA0AAA 208/230-3 45,000 120,000 610 RGS048LFAA0AAA 460-3 45,000 120,000 610 RGS060KDAA0AAA 208/230-1 59,000 59,000 620 RGS060HDAA0AAA 208/230-3 36,000 59,000 620 RGS060LDAA0AAA 460-3 59,000 59,000 620 RGS060SEAA0AAA 575-3 59,000 93,000 620 RGS060KEAA0AAA 208/230-1 59,000 93,000 620 RGS060HEAA0AAA 208/230-3 59,000 93,000 620 RGS060LEAA0AAA 460-3 59,000 93,000 620 RGS060SFAA0AAA 575-3 59,000 120,000 630 RGS060KFAA0AAA 208/230-1 59,000 120,000 630 RGS060HFAA0AAA 208/230-3 59,000 120,000 630 RGS060LFAA0AAA 460-3 59,000 120,000 630 RGS072HDAA0AAA 208/230-3 70,000 59,000 657 RGS072LDAA0AAA 460-3 70,000 59,000 657 RGS072SEAA0AAA 575-3 70,000 93,000 657 RGS072HEAA0AAA 208/230-3 70,000 93,000 657 RGS072LEAA0AAA 460-3 70,000 93,000 657 RGS072SFAA0AAA 575-3 70,000 120,000 664 RGS072HFAA0AAA 208/230-3 70,000 120,000 664 RGS072LFAA0AAA 460-3 70,000 120,000 664 RGS091HDAA0AAA 208/230-3 84,000 103,000 810 RGS091LDAA0AAA 460-3 84,000 103,000 810 RGS091SEAA0AAA 575-3 84,000 148,000 810 RGS091HEAA0AAA 208/230-3 84,000 148,000 810 RGS091LEAA0AAA 460-3 84,000 148,000 810 RGS091SFAA0AAA 575-3 84,000 184,000 810 RGS091HFAA0AAA 208/230-3 84,000 184,000 810 RGS091LFAA0AAA 460-3 84,000 184,000 810 RGS101HDAA0AAA 208/230-3 97,000 103,000 910

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

4

RGS STANDARD UNIT MASTER PRICES SINGLE Compressor Models

SAP CATALOG ORDERING NUMBER

VOLTS-PHASE (60 Hz)

COOLING CAPACITY

(Btuh)

HEATING OUTPUT

(Btuh)

APPROX. SHIP. WT.

(Lbs)

MASTER PRICE

RGS101LDAA0AAA 460-3 97,000 103,000 910 RGS101SEAA0AAA 575-3 97,000 148,000 910 RGS101HEAA0AAA 208/230-3 97,000 148,000 910 RGS101LEAA0AAA 460-3 97,000 148,000 910 RGS101SFAA0AAA 575-3 97,000 184,000 910 RGS101HFAA0AAA 208/230-3 97,000 184,000 910 RGS101LFAA0AAA 460-3 97,000 184,000 910 RGS121HDAA0AAA 208/230-3 117,000 148,000 965 RGS121LDAA0AAA 460-3 117,000 148,000 965 RGS121SEAA0AAA 575-3 117,000 184,000 965 RGS121HEAA0AAA 208/230-3 117,000 184,000 965 RGS121LEAA0AAA 460-3 117,000 184,000 965 RGS121SFAA0AAA 575-3 117,000 205,000 965 RGS121HFAA0AAA 208/230-3 117,000 205,000 965 RGS121LFAA0AAA 460-3 117,000 205,000 965

* Rated in accordance with ARI Standards 210/240, 270 (036-120)

ALL of the above models comply with the minimum efficiency requirements as defined in the ASHRAE 90.1-2004 Energy Standard. To determine local compliance check with local or state municipal building codes or access the Internet website: http://bcap-energy.org

BASE UNIT MASTER PRICES - TWO STAGE COOLING MODELS ORDERING

NUMBER VOLTAGE/ PHASE/HZ

HEAT LEVEL OUTPUT

(Btuh)

COOLING CAPACITY

(Btuh)

APPROX. SHIPPING WT. (lbs)

MASTER PRICE

RGS090HDAA0GAA 208/230-3-60 103,000 83,000 890 RGS090LDAA0GAA 460-3-60 103,000 83,000 890 RGS090SEAA0GAA 575-3-60 148,000 83,000 890 RGS090HEAA0GAA 208/230-3-60 148,000 83,000 890 RGS090LEAA0GAA 460-3-60 148,000 83,000 890 RGS090SFAA0GAA 575-3-60 184,000 83,000 890 RGS090HFAA0GAA 208/230-3-60 184,000 83,000 890 RGS090LFAA0GAA 460-3-60 184,000 83,000 890 RGS090HDAA0GAA 208/230-3-60 148,000 114,000 970 RGS120HDAA0GAA 208/230-3-60 148,000 114,000 970 RGS120LDAA0GAA 460-3-60 148,000 114,000 970 RGS120SEAA0GAA 575-3-60 184,000 114,000 970 RGS120HEAA0GAA 208/230-3-60 184,000 114,000 970 RGS120LEAA0GAA 460-3-60 184,000 114,000 970 RGS120SFAA0GAA 575-3-60 205,000 114,000 970 RGS120HFAA0GAA 208/230-3-60 205,000 114,000 970 RGS120LFAA0GAA 460-3-60 205,000 114,000 970 RGS150HDAA0GAA 208/230-3-60 148,000 140,000 1156 RGS150LDAA0GAA 460-3-60 148,000 140,000 1156 RGS150SEAA0GAA 575-3-60 184,000 140,000 1156 RGS150HEAA0GAA 208/230-3-60 184,000 140,000 1156 RGS150LEAA0GAA 460-3-60 184,000 140,000 1156 RGS150SFAA0GAA 575-3-60 205,000 140,000 1156 RGS150HFAA0GAA 208/230-3-60 205,000 140,000 1156 RGS150LFAA0GAA 460-3-60 205,000 140,000 1156

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

5

RGS LOW NOX BASE UNIT MASTER PRICES SAP CATALOG

ORDERING NUMBER

VOLTS-PHASE (60 Hz)

COOLING CAPACITY

(Btuh)

HEATING OUTPUT

(Btuh)

APPROX. SHIP. WT.

(Lbs)

MASTER PRICE

RGS036KLAA0AAA 208/230-1 34,600 59,000 572 RGS036HLAA0AAA 208/230-3 34,600 59,000 572 RGS036LLAA0AAA 460-3 34,600 59,000 572 RGS036KMAA0AAA 208/230-1 34,600 74,000 572 RGS036HMAA0AAA 208/230-3 34,600 74,000 572 RGS036LMAA0AAA 460-3 34,600 74,000 572 RGS048KLAA0AAA 208/230-1 45,000 59,000 582 RGS048HLAA0AAA 208/230-3 45,000 59,000 582 RGS048LLAA0AAA 460-3 45,000 59,000 582 RGS048KMAA0AAA 208/230-1 45,000 74,000 602 RGS048HMAA0AAA 208/230-3 45,000 74,000 602 RGS048LMAA0AAA 460-3 45,000 74,000 602 RGS048KNAA0AAA 208/230-1 45,000 101,000 610 RGS048HNAA0AAA 208/230-3 45,000 101,000 610 RGS048LNAA0AAA 460-3 45,000 101,000 610 RGS060KLAA0AAA 208/230-1 59,000 59,040 620 RGS060HLAA0AAA 208/230-3 59,000 59,000 620 RGS060LLAA0AAA 460-3 59,000 59,000 620 RGS060KMAA0AAA 208/230-1 59,000 74,000 620 RGS060HMAA0AAA 208/230-3 59,000 74,000 620 RGS060LMAA0AAA 460-3 59,000 74,000 620 RGS060KNAA0AAA 208/230-1 59,000 101,000 630 RGS060HNAA0AAA 208/230-3 59,000 101,000 630 RGS060LNAA0AAA 460-3 59,000 101,000 630

Units meet California’s South Coast Air Quality Management District (SCAQMD) requirement of 40 nanograms / joule or less.

ALL of the above models comply with the minimum efficiency requirements as defined in the ASHRAE 90.1-2004 Energy Standard. To determine if compliance with this standard pertains to a given geographical area of the United States, check with local or state municipal building codes or visit the following Internet website: http://bcap-energy.org.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

6

STAINLESS STEEL HEAT EXCHANGER OPTION MASTER PRICES ( Single Compressor )

SAP CATALOG ORDERING NUMBER

VOLTS-PHASE (60 Hz)

COOLING CAPACITY

(Btuh)

HEATING OUTPUT

(Btuh)

APPROX. SHIP. WT.

(Lbs)

MASTER PRICE

RGS101HRAA0AAA 208/230-3 97,000 148,000 910 RGS101LRAA0AAA 460-3 97,000 148,000 910 RGS101STAA0AAA 575-3 97,000 184,000 910 RGS101HTAA0AAA 208/230-3 97,000 184,000 910 RGS101LTAA0AAA 460-3 97,000 184,000 910 RGS121HSAA0AAA 208/230-3 117,000 148,000 965 RGS121LSAA0AAA 460-3 117,000 148,000 965 RGS121SRAA0AAA 575-3 117,000 184,000 965 RGS121HRAA0AAA 208/230-3 117,000 184,000 965 RGS121LRAA0AAA 460-3 117,000 184,000 965 RGS121STAA0AAA 575-3 117,000 205,000 965 RGS121HTAA0AAA 208/230-3 117,000 205,000 965 RGS121LTAA0AAA 460-3 117,000 205,000 965

STAINLESS STEEL HEAT EXCHANGER OPTION MASTER PRICES ( Dual Compressor ) SAP CATALOG

ORDERING NUMBER

VOLTAGE/ PHASE/HZ

HEAT LEVEL OUTPUT

(Btuh)

COOLING CAPACITY

(Btuh)

APPROX. SHIPPING WT. (lbs)

MASTRR PRICR

RGS090HSAA0GAA 208/230-3-60 103,000 83,000 900 RGS090LSAA0GAA 460-3-60 103,000 83,000 900 RGS090SRAA0GAA 575-3-60 148,000 83,000 900 RGS090HRAA0GAA 208/230-3-60 148,000 83,000 900 RGS090LRAA0GAA 460-3-60 148,000 83,000 900 RGS090STAA0GAA 575-3-60 184,000 83,000 900 RGS090HTAA0GAA 208/230-3-60 184,000 83,000 900 RGS090LTAA0GAA 460-3-60 184,000 83,000 900 RGS120HSAA0GAA 208/230-3-60 148,000 114,000 980 RGS120LSAA0GAA 460-3-60 148,000 114,000 980 RGS120SRAA0GAA 575-3-60 184,000 114,000 980 RGS120HRAA0GAA 208/230-3-60 184,000 114,000 980 RGS120LRAA0GAA 460-3-60 184,000 114,000 980 RGS120STAA0GAA 575-3-60 205,000 114,000 980 RGS120HTAA0GAA 208/230-3-60 205,000 114,000 980 RGS120LTAA0GAA 460-3-60 205,000 114,000 980 RGS150HSAA0GAA 208/230-3-60 148,000 140,000 1166 RGS150LSAA0GAA 460-3-60 148,000 140,000 1166 RGS150SRAA0GAA 575-3-60 184,000 140,000 1166 RGS150HRAA0GAA 208/230-3-60 184,000 140,000 1166 RGS150LRAA0GAA 460-3-60 184,000 140,000 1166 RGS150STAA0GAA 575-3-60 205,000 140,000 1166 RGS150HTAA0GAA 208/230-3-60 205,000 140,000 1166 RGS150LTAA0GAA 460-3-60 205,000 140,000 1166

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

7

FACTORY INSTALLED OPTIONS

POSITION 9 – INDOOR MOTOR OPTIONS

RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R G S 0 7 2 L D A B 0 A A A

MASTER PRICE ADDERS 9th

DIGIT ORDER CODE

DESCRIPTION VOLTAGE 036 048 060 072 090 /

091 101 120 / 121 150

208/230-1-60 Std. Std. Std. Std. Std. Std. Std. Std. 208/230-3-60 or 460-3-60 Std. Std. Std. Std. Std. Std. Std. Std. A Standard

Static Option 575-3-60 Std. Std. Std. Std. Std. Std. Std. Std.

208/230-1-60 NC NC Cost Add -n/a n/a n/a n/a n/a 208/230-3-60 or 460-3-60

Cost Add

Cost Add Cost Add Cost

Add Cost Add

Cost Add Cost Add Cost

Add B High Static Option

575-3-60 Cost Add

Cost Add Cost Add Cost

Add Cost Add

Cost Add Cost Add Cost

Add

POSITION 10 - OUTDOOR AIR OPTIONS

RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R G S 0 7 2 L D A B 0 A A A

10th DIGIT ORDER DESCRIPTION MASTER PRICE ADDER

CODE 036-072 091-150 A None Std. Std. B Temperature Economizer w/ Barometric relief Cost Add Cost Add E Temperature Economizer w/ Barometric relief and CO2 1 Cost Add Cost Add H Enthalpy Economizer w/ Barometric relief Cost Add Cost Add L Enthalpy Economizer w/ Barometric relief and CO2 1 Cost Add Cost Add P Motorized 2 pos damper w/ Barometric relief Cost Add Cost Add

1 Future availability

NOTES: 1. EconoMi$er IV (Vertical airflow only): • 100%+ barometric relief capability. • Gear-driven 3-position damper. Includes occupied/unoccupied minimum position and maximum position. • Direct-mount Belimo spring return actuator closes damper on power loss. • Dry bulb outdoor air control standard. Enthalpy control available as an accessory. • Solid-state control module for non-DDC applications • OAT and SAT sensors factory installed

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

8

FACTORY INSTALLED OPTIONS

POSITION 11 & 12 - FACTORY-INSTALLED OPTIONS

RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R G S 0 7 2 L D A B 0 A A A

To determine the Option Ordering Code and place an order: 1. Select the desired combination of options from the table below. The 2-letter Ordering Code is listed to the left of the Option

combination. 2. Enter the 2-letter Code as the 11th and 12th digits of the Base Unit Ordering Number. 3. To determine Master Price for FIOP unit, add price of option combination selected to master price of base unit.

FACTORY-INSTALLED OPTION DESCRIPTIONS

OPTION DESCRIPTION NOTES 2 Non-Fused Disconnect Switch 2 5 Un-powered Convenience Outlet 3 9 Supply Air Smoke Detector

FACTORY-INSTALLED OPTION PRICES

ORDER OPTIONS MASTER PRICE ADDER CODE 036-072 091-150

0A None Standard Standard 4B 2 Cost Add Cost Add 7C 2,5 Cost Add Cost Add 7K 2,5,9 Cost Add Cost Add 8A 2,9 Cost Add Cost Add AT 5 Cost Add Cost Add BR 5,9 Cost Add Cost Add

NOTES: 2. Non-fused disconnect switch cannot be used when rooftop MOCP electrical rating exceeds 80 amps. 3. Un-powered convenience outlet requires separate field supplied 115-120v power source. Transformer is NOT

included.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

9

FACTORY INSTALLED OPTIONS

POSITION 13 - CORROSION RESISTANT COILS

RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R G S 0 7 2 L D A B 0 A A A

Environment

Enviro-Shield™ Description

Standard Non-Corrosive

Mild Coastal Moderate Coastal

Severe Coastal

Industrial Industrial & Coastal

Alum Fin / Cu Tube X Pre-Coated Al / Cu X Cu / Cu X E-Coated Al / Cu X XE-Coated Cu / Cu X

SINGLE STAGE ( 1 Compressor ) COOLING CAPACITY MODELS ( 091-121 ONLY)

13th MASTER PRICE ADDERS Digit Condenser Order Coil 036 048 060 072 091 101 121 Code (Fins/Tube)

Evaporator Coil

(Fins/Tube) A Al/Cu Al/Cu Std. Std. Std. Std. Std. Std. Std. B Pre-

C t dAl/Cu Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add

C E-Coated Al/C

Al/Cu Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add

D E-Coated Al/C

E-Coated Al/C

Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add

E Cu/Cu Al/Cu Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add

F Cu/Cu Cu/Cu Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add Cost Add

TWO STAGE ( Dual Compressor ) COOLING CAPACITY MODELS ( 090-150 ONLY)

13th DESCRIPTION MASTER PRICE ADDERS Digit Condenser Order Coil Code (Fins/Tube)

Evaporator Coil

(Fins/Tube) 090 120 150

G AL/AL AL/CU Std. Std. Std.

K E-Coat Al / Al AL/CU Cost Add Cost Add Cost Add Notes: 1. Dual stage ( 2 compressor ) models are equipped with a micro-channel (MCHX) aluminum / aluminum condenser coil. 2. No MCHX factory coating options are currently available.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

10

FIELD INSTALLED ACCESSORIES

ECONOMI$ER IV (CONTROLLER INCLUDED)

VERTICAL ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE APPROXSHIP WT

(Lbs)

MASTER PRICE

DNECOMZR020A02 1

Vertical EconoMi$er IV with solid-state controller, gear-driven, 3-position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in non-DDC applications.

036-072 55

DNECOMZR021A03 1

Vertical EconoMi$er IV with solid-state controller, gear-driven, 3-position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in non-DDC applications.

090-150 80

NOTE: 1 EconoMi$er IV, EconoMi$er2, Manual Damper and Motorized Damper are all mutually exclusive and cannot be installed together.

HORIZONTAL ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE APPROXSHIP WT

(Lbs)

MASTER PRICE

DNECOMZR024A02 1

Horizontal EconoMi$er IV with solid-state controller, gear-driven, 3-position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in non-DDC applications.

036-072 85

DNECOMZR025A02 1

Horizontal EconoMi$er IV with solid-state controller, gear-driven, 3-position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in non-DDC applications.

090-150 105

NOTE: 1 EconoMi$er IV, Manual Damper and 2-Pos Motorized Damper are all mutually exclusive and cannot be installed together.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

11

FIELD INSTALLED ACCESSORIES

ECONOMIZER SENSORS ECONOMIZER SENSOR USAGE CHART

ECONOMI$ER IV 1 DESIRED CONTROL METHOD

REQUIRED FIELD-INSTALLED SENSOR(S)

Single Dry Bulb Control

None. Outside Air dry bulb sensor is factory installed.

Differential Dry Bulb Control (1) DNTEMPSN002A00

Single Enthalpy Control (1 AXB078ENT

Differential Enthalpy Control

(1) AXB078ENT & (1) DNENTDIF004A00

To Add CO2 DCV Control with above:

Duct Mount

(1) DNCBDIOX005A00

NOTES:

1. OAT and SAT sensors included for EconoMi$er IV.

ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE

DNTEMPSN002A00 Outdoor or Return Dry Bulb Temperature Sensor used with Electro-Mechanical control. EconoMi$er IV

DNCBDIOX005A00 CO2 Sensor for use in return air stream. Also includes Aspirator Box required for Duct Mounting. EconoMi$er IV

AXB078ENT Accusensor II Economizer Differential Enthalpy Control Upgrade EconoMi$er IV DNENTDIF004A00 Return Air Enthalpy Sensor used with Electro-Mechanical controls,

use with AXB078ENT for differential enthalpy control. EconoMi$er IV

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

12

FIELD INSTALLED ACCESSORIES

POWER EXHAUST OPTIONS

VERTICAL 1 ODS ORDERING

NUMBER DESCRIPTION APPLICATION USAGE

DNPWREXH030A01 Power Exhaust System (208/230-1-60) 036-072

208/230-1-60 208/230-3-60

DNPWREXH021A01 Power Exhaust System (460-3-60) 036-072 460-3-60

DNPWREXH022A01 Power Exhaust System (208/230-1-60) 090-150 208/230-3-60

DNPWREXH023A01 Power Exhaust System (460-3-60) 090-150 460-3-60

NOTES: 1 Vertical Power Exhaust requires a vertical Economizer 2 Vertical Power Exhaust package includes exhaust hood, screens, and propeller fan system

HORIZONTAL

ODS ORDERING NUMBER

DESCRIPTION APPLICATION USAGE

DNPWREXH028A01 Horizontal Power Exhaust (208/230-1-60) - Mounted on Return Ductwork

All 208/230-1-60 208/230-3-60

575-3-60

DNPWREXH029A01 Horizontal Power Exhaust (460-3-60) - Mounted on Return Ductwork

All 460-3-60

NOTES: 1 Horizontal Power Exhaust should be duct-mounted in the return duct 2 Horizontal Power Exhaust package includes exhaust hood, screens, and propeller fan system

575V TRANSFORMER ODS ORDERING

NUMBER / FAST # DESCRIPTION APPLICATION USAGE

--HT--01AH-859 / 1171494

Transformer for conversion from 575 volt to 208/230 volt power exhaust applications.

Convert from 575 Volt to 208-230 Volt Power Exhaust

applications.

NOTES: 1. Vertical power exhaust package includes exhaust hood, screens and propeller fan system. 2. 24” Roof curbs are NOT required with vertical power exhaust. 3. Horizontal power exhaust should be duct-mounted in the return ductwork and is supplied with a single fan and wiring harness. 4. Both vertical and horizontal power exhaust packages can be used with either EconoMi$er IV. In either case, the power exhaust is

controlled by the EconoMi$er IV controller. 5. Order --HT--01AH-859, FAST# 1171494, for 575V applications.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

13

FIELD INSTALLED ACCESSORIES

OUTDOOR AIR DAMPER OPTIONS

MANUAL OUTDOOR AIR DAMPERS ODS ORDERING

NUMBER DESCRIPTION APPLICATION USAGE MASTER

PRICE

DNMANDPR001A03 25% Open Manual Outdoor Air Damper Package 036-072 1 CRMANDPR001A02 50% Open Manual Outdoor Air Damper Package 036-072 1 DNMANDPR002A03 25% Open Manual Outdoor Air Damper Package 090-1501 CRMANDPR002A02 50% Open Manual Outdoor Air Damper Package 090-1501

\

1 EconoMi$er IV, Manual Damper and 2-Pos Motorized Damper are all mutually exclusive and cannot be installed together.

MOTORIZED OUTDOOR AIR DAMPERS

ODS ORDERING NUMBER

DESCRIPTION APPLICATION USAGE MASTER PRICE

CRTWOPOS010A00 Motorized 2-position outdoor air damper (25-100% Outdoor Air)

036-072 1

CRTWOPOS011A00 Motorized 2-position outdoor air damper 091-150 1

1 EconoMi$er IV, Manual Damper and 2-Pos Motorized Damper are all mutually exclusive and cannot be installed together. NOTES: 1. Manual dampers include hood assembly, bird screen, adjustable damper blade (to allow up to the rated outdoor air %), and bottom

panel with opening. 2. Motorized dampers include bottom panel with opening (100% two-position damper includes 30% barometric relief capability), and

adjustable damper (to allow up to the rated outdoor air %). 3. Motorized dampers will close on loss of power to the rooftop unit. Manual and Motorized dampers are not compatible with a vertical power exhaust module

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

14

FIELD INSTALLED ACCESSORIES

ROOF CURB OPTIONS

STANDARD ROOF CURBS ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE MASTER

PRICE CRRFCURB001A01 14-inch Tall Roof Curb. Complies with NRCA standards. Ductwork

attaches to the roof curb. Includes thru-the-bottom capability. 036-072

CRRFCURB003A01 14-inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thru-the-bottom capability. 090-150

CRRFCURB002A01 24-inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thru-the-bottom capability. 036-072

CRRFCURB004A01 24-inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thru-the-bottom capability. 090-150

THRU-THE-BOTTOM CONNECTION KITS ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE MASTER

PRICE

CRBTMPWR001A01

Thru-the-bottom electrical connections and thru-the-curb (not thru the bottom) gas connections. Includes a 3/4-inch diameter liquid tight conduit

fitting for high voltage power wires and (2) 1/2-inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a

3/4-inch inside pipe coupling and gas plate assembly for thru-the-curb connections. Provides for watertight seals.

036-072

CRBTMPWR002A01

Thru-the-bottom electrical connections and thru-the-curb (not thru the bottom) gas connections. Includes a 1-1/4-inch diameter liquid tight conduit

fitting for high voltage power wires and (2) 1/2-inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a

3/4-inch inside pipe coupling and gas plate assembly for thru-the-curb connections. Provides for watertight seals.

090-150

CRBTMPWR003A01

Thru-the bottom power, control and gas connections. Includes a 3/4-inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2-inch diameter liquid tight conduits for thermostat wires and convenience outlet

wires and 1/2-inch gas adapter fitting for gas piping. Provides for watertight seal.

036-072

CRBTMPWR004A01

Thru-the bottom power, control and gas connections. Includes a 1-1/4-inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2-inch diameter liquid tight conduits for thermostat wires and convenience outlet

wires and 3/4-inch gas adapter fitting for gas piping. Provides for watertight seal.

090-150

NOTE: Access to the bottom of the RTU is required to install a THRU-THE-BOTTOM Connection Kit. Recommend installing kit prior to installing RTU on roof curb.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

15

FIELD INSTALLED ACCESSORIES Table 1. NATURAL GAS & NATURAL GAS LOW NOX HIGH ALTITUDE KITS 036-072 ( 3-6t)

Unit Size - Natural Gas Unit Size - Natural Gas - LOW NOX ELEVATIO

N UNIT SIZE 036 048 060 072 ELEVATION UNIT SIZE 036 048 060 Ft (m) Heat Size / Input CRLPELEV****** Required Ft (m) Heat Size / Input CRLPELEV****** Required

Low / 72,000 Std Std Std Std Low / 60,000 Std Std Std Med / 115,000 Std Std Std Std Med / 90,000 Std Std Std 0 - 2000

(610) High / 150,000 NA Std Std Std

0 - 2000 (610)

High / 120,000 NA Std Std Low / 72,000 Low / 60,000

Med / 115,000 001A00 Med / 90,000 002A00 2000 (610) High / 150,000 t 30

2000 (610) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 Med / 90,000

t40 3000 (914) High / 150,000

001A00

3000 (914) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 Med / 90,000

t41 4000 (1219) High / 150,000

001A00

4000 (1219) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 Med / 90,000

t41 5000 (1524) High / 150,000

001A00

5000 (1524) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 002A00 Med / 90,000

t42 6000 (1829) High / 150,000 001A00

6000 (1829) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 002A00 Med / 90,000

t42 7000 (2134) High / 150,000 001A00

7000 (2134) High / 120,000 001A00

Low / 72,000 Low / 60,000 Med / 115,000 002A00 Med / 90,000

t43 8000 (2438) High / 150,000 001A00

8000 (2438) High / 120,000 002A00

Low / 72,000 Low / 60,000 Med / 115,000

t 40 Med / 90,000 t43 9000 (2743)

High / 150,000 001A00 9000 (2743)

High / 120,000 002A00 Low / 72,000 Low / 60,000

Med / 115,000 t 41 Med / 90,000 002A00 10000

(3048) High / 150,000 001A00

10000 (3048) High / 120,000 t40

Low / 72,000 Low / 60,000 Med / 115,000

t 42 Med / 90,000 002A00 11000 (3353)

High / 150,000 001A00 11000 (3353)

High / 120,000 t41 Low / 72,000 Low / 60,000

Med / 115,000 t 43 Med / 90,000 002A00 12000

(3658) High / 150,000 002A00

12000 (3658) High / 120,000 t42

Low / 72,000 Low / 60,000 Med / 115,000

t 43 Med / 90,000 003A00 13000 (3962)

High / 150,000 002A00 13000 (3962)

High / 120,000 t43 Low / 72,000 Low / 60,000

Med / 115,000 002A00 Med / 90,000 003A00 14000 (4267)

High / 150,000 t 40 14000 (4267)

High / 120,000 t43

t Orifice size listed - not a kit - must be purchased separately from FAST. See product specification sheets for number required.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

16

FIELD INSTALLED ACCESSORIES

Table 2. NATURAL GAS HIGH ALTITUDE KITS 090 – 150 ( 7.5 – 12.5t) Unit Size

ELEVATION UNIT SIZE 090 / 091 101 UNIT SIZE 120 / 121 150

Ft (m) Heat Size / Input CRLPELEV******

Required Heat Size / Input CRLPELEV******

Required Low / 125,000 Std Std Low / 180,000 Std Std Med / 180,000 Std Std Med / 224,000 Std Std 0 - 2000

(610) High / 224,000 Std Std High / 250,000 Std Std Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 001A00

2000 (610) High / 224,000 001A00 High / 250,000 t 30 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

3000 (914) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

4000 (1219) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

5000 (1524) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

6000 (1829) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

7000 (2134) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

8000 (2438) High / 224,000 001A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 002A00

9000 (2743) High / 224,000 002A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 002A00

10000 (3048) High / 224,000 002A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 002A00

11000 (3353) High / 224,000 002A00 High / 250,000 001A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 t 41

12000 (3658) High / 224,000 t 41 High / 250,000 002A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 t 42

13000 (3962) High / 224,000 t 42 High / 250,000 002A00 Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 t 43

14000 (4267) High / 224,000 t 43 High / 250,000 t 40 t Orifice size listed - not a kit - must be purchased separately from FAST. See product specification sheets for number required.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

17

FIELD INSTALLED ACCESSORIES

Table 3. PROPANE GAS, PROPANE GAS LOW NOX, AND PROPANE GAS HIGH ALTITUDE KITS

036-072 ( 3-6t) Unit Size

Unit Size - LP Gas Unit Size - LP Gas -

LOW NOX ELEVATION UNIT SIZE 036 048 060 072 ELEVATION UNIT SIZE 036 048 060

Ft (m) Heat Size / Input CRLPELEV****** Required Ft (m) Heat Size / Input CRLPELEV******

Required Low / 72,000 004A00 Low / 60,000 004A00

Med / 115,000 003A00 Med / 90,000 004A00 0 - 2000 (610) High / 150,000 NA 003A00

0 - 2000 (610)

High / 120,000 NA 003A00 Low / 72,000 Low / 60,000

Med / 115,000 004A00

Med / 90,000 2000 (610) High / 150,000 003A00

2000 (610) High / 120,000

004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 3000 (914)

High / 150,000 003A00 3000 (914)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 4000 (1219)

High / 150,000 003A00 4000 (1219)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 5000 (1524)

High / 150,000 003A00 5000 (1524)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 6000 (1829)

High / 150,000 003A00 6000 (1829)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 7000 (2134)

High / 150,000 003A00 7000 (2134)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 8000 (2438)

High / 150,000 003A00 8000 (2438)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 9000 (2743)

High / 150,000 003A00 9000 (2743)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000

004A00 Med / 90,000 10000 (3048)

High / 150,000 003A00

10000 (3048)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000 Med / 90,000 11000 (3353) High / 150,000

004A00

11000 (3353)

High / 120,000 004A00

Low / 72,000 Low / 60,000 Med / 115,000 Med / 90,000

t56 12000 (3658) High / 150,000

004A00

12000 (3658)

High / 120,000 004A00 Low / 72,000 Low / 60,000

Med / 115,000 Med / 90,000 t56 13000 (3962)

High / 150,000 004A00

13000 (3962)

High / 120,000 004A00 Low / 72,000 t 56 Low / 60,000

Med / 115,000 Med / 90,000 t56 14000 (4267)

High / 150,000 004A00

14000 (4267)

High / 120,000 004A00

t Orifice size listed - not a kit - must be purchased separately from FAST. See product specification sheets for number required.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

18

FIELD INSTALLED ACCESSORIES Table 4. PROPANE GAS AND PROPANE GAS HIGH ALTITUDE KITS

090-150 ( 7.5-12.5t) Unit Size -

ELEVATION UNIT SIZE 090 / 091 101 UNIT SIZE 120 / 121 150

Ft (m) Heat Size / Input CRLPELEV******

Required Heat Size / Input CRLPELEV******

Required Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 0 - 2000 (610) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 2000 (610) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 3000 (914) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 4000 (1219) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 004A00 Low / 180,000 Med / 180,000 Med / 224,000 5000 (1524) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 004A00 Low / 180,000 Med / 180,000 Med / 224,000 6000 (1829) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 004A00 Low / 180,000 Med / 180,000 Med / 224,000 7000 (2134) High / 224,000

003A00 High / 250,000

003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

004A00 8000 (2438) High / 224,000

004A00 High / 250,000 003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

004A00 9000 (2743) High / 224,000

004A00 High / 250,000 003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000

004A00 10000 (3048) High / 224,000

004A00 High / 250,000 003A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 11000 (3353) High / 224,000

004A00 High / 250,000

004A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 12000 (3658) High / 224,000

004A00 High / 250,000

004A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 13000 (3962) High / 224,000

004A00 High / 250,000

004A00

Low / 125,000 Low / 180,000 Med / 180,000 Med / 224,000 14000 (4267) High / 224,000

004A00 High / 250,000

004A00

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

19

FIELD INSTALLED ACCESSORIES

LIQUID PROPANE (LP) / HIGH ALTITUDE GAS KITS ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE

CRLPELEV001A00 LP and Hi Altitude conversion kit. Contains spuds sizes 31, 32, 33, 35, and

36 (5 spuds/ size) and other necessary conversion parts. Use this kit to convert Natural Gas rooftops to LP and/or high altitude applications.

All

CRLPELEV002A00 LP and Hi Altitude conversion kit. Contains spuds sizes 37, 38, 39, 44, and

45 (5 spuds/size) and other necessary conversion parts. Use this kit to convert Natural Gas rooftops to LP and/or high altitude applications.

All

CRLPELEV003A00 LP and Hi Altitude conversion kit. Contains spuds sizes 46, 47, 48, 49, and

50 (5 spuds/size) and other necessary conversion parts. Use this kit to convert Natural Gas rooftops to LP and/or high altitude applications.

All

CRLPELEV004A00 LP and Hi Altitude conversion kit. Contains spuds sizes 51, 52, 53, 54, and

55 (5 spuds/size) and other necessary conversion parts. Use this kit to convert Natural Gas rooftops to LP and/or high altitude applications.

All

HEATING UPGRADE KITS ODS ORDERING

NUMBER DESCRIPTION APPLICATION

USAGE

CRFLUEDS001A00 Flue Discharge Deflector -- Directs flue gas exhaust 90 degrees upward from current discharge. Designed to allow tighter distances between unit and combustible surfaces. 24 inch Height. AGA certified. 1

All

CRFLUEHD001A01 Flue Exhaust Heat Shield -- Provides a sheet metal guard around the flue gas hood which prevents service personnel or small children from coming into contact with the flue hood. 1

All

1 CRFLUEDS001A00 and CRFLUEHD001A01 are mutually exclusive. Cannot install both on the same unit.

CONTROL UPGRADE KITS ODS ORDERING

NUMBER / FAST # DESCRIPTION APPLICATION

USAGE

DNSTATUS001A00 Fan/Filter Status Switch - Indicator light not included Std. Control

DNTIMEGD001A00

Time Guard II -- Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied or with a PremierLink or RTU-MP control.

All Sizes (1 required)

DNPHASE3001A02 Phase Monitor Control - Provides phase loss/phase reversal protection All 3-Ph 208-230 & 460v

DNWINSTR001A00 Winter Start Package - Contains time delay relay for timed bypass of low pressure switch on startup. 1 All

--KA--99ZT-003 / 1178184

Remote keyed attenuator / test / reset station for use with factory installed smoke detectors. Includes power, alarm & trouble indicator lights. All

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

20

FIELD INSTALLED ACCESSORIES LOW AMBIENT CONTROLS

Motormaster I Usage and Parts Table (036-121 Models) Table 5 - Single Phase Unit

Capacitor Replacement

UNITS VOLTAGE MOTOR CAPACITOR MOTORMASTER I

CONTROLLER UNITS DUAL MFD*

FAST / RCD PART #

208/230-1-60 HC40GE233

FAST# 1171974

See table 5 32LT900301

FAST#

RGS036K 45 + 10

HC98JA048 FAST#

208/230-3-60 575-3-60*

HC40GE233

FAST# 1171974

Replace withHC91CL010

FAST#

32LT900301

FAST#

RGS048K 70 + 10

HC98JA073 FAST#

RGS036-060

460-3-60 HC40GE463

FAST# 1171975

Replace withHC91CL010

FAST#

32LT900611 FAST#

RGS060K 80 + 10

HC98JA083 FAST#

208/230-3-60 HC40GE233

FAST# 1171974

Keep Factory Installed

32LT900301

FAST#

*Compressor shares capacitor with the OD motor, the first number is for compressors and the second number is for OD motor

460-3-60 HC40GE463

FAST# 1171975

Replace withHC91CL010

FAST#

32LT900611

FAST#

RGS072

575-3-60* HC40GE233 FAST# 1171974

Replace withHC91CL010

FAST#

32LT900301 FAST#

208/230-3-60 575-3-60**

(2) HC40GE233 FAST# 1171974

Replace withHC93CA013

FAST#

32LT900301 FAST#

RGS091-121 (Single

Compressor Units) 460-3-60 (2) HC40GE463

FAST# 1171975

Replace withHC93CA013

FAST#

32LT900611 FAST#

208/230-3-60 575-3-60**

(2) HC40GE233 FAST# 1171974

Keep Factory Installed

32LT901247 FAST#

RGS090-120 (Dual

Compressor Units with

Microchannel Al/Al

condenser coil)

460-3-60 (2) HC40GE463

FAST# 1171975

Keep Factory Installed

32LT901247 FAST#

The Capacitor Straps in the unit can be reused. If needed part numbers are as follows: HC91CL005 / FAST# 1172149 & HC91CL010 / FAST# 1171807 use HC98ZY071/FAST# 1171552, and HC93CA013 / FAST# 1175708 uses 50DK507522 / FAST# 1171537. *Transformer HT01AH856 / FAST# 1178302 (0.75kva, 575v to 230v) and transformer bracket 50DK502263 / FAST# 1171069 are recommended. **Transformer HT01AH859 / FAST# 1171494 (1kva, 575v to 230v) and transformer bracket 50DK502263 / FAST# 1171069 are recommended.

Commercial Products Matrix RGS

3 TO 12.5 TONS

PAGE SUPERSEDE DATE New EFFECTIVE DATE Rev.J 9/4/2009

21

FIELD INSTALLED ACCESSORIES LOW AMBIENT CONTROLS (SIZE 036-121) MASTER PRICES

ODS ORDERING NUMBER / FAST #

DESCRIPTION APPLICATION USAGE

AXB035LAA s/a CPLOWAMB001A00

Motormaster® II Low Ambient Control - Enables cooling system to operate down to 0° F by cycling condenser fan on

and off. The control is activated by a temperature sensor. No motor change-out required.

208/230-1 208/230-3 460-3-60 All Sizes

32LT-900---301 Motormaster I Single-Phase Solid-State Variable Speed

Motor Controller enables cooling down to -20° F by varying the speed on the condenser fan.

32LT-900---611 Motormaster I Single-Phase Solid-State Variable Speed

Motor Controller enables cooling down to -20° F by varying the speed on the condenser fan.

Refer to Motormaster I Usage Table

32LT-901---247 Motormaster I Single --Phase Solid-State Variable Speed

Motor Controller enables cooling down to -20° F by varying the speed on the condenser fan.

32LT-901---647 Motormaster I Single - Phase Solid-State Variable Speed

Motor Controller enables cooling down to -20° F by varying the speed on the condenser fan.

Refer to Motormaster I Usage Table

HC40GE233 / 1171974 Motormaster I Compatible Condenser Fan Motor

HC40GE463 / 1171975 Motormaster I Compatible Condenser Fan Motor

HC91CL010 / 171807 MFD 10 HC93CA013 /

1175708 Dual MFD 10 + 10

HC98JA048 / 1173702 Dual MFD 45 + 10

HC98JA073 / 1177750 Dual MFD 70 + 10

HC98JA083 / 1173703 Dual MFD 80 + 10

Refer to Motormaster I Usage Table

NOTES:

* FAST List Price - Subject to change on a quarterly basis and should be verified with FAST prior to quoting.

• Sizes 036-072 require one (1) Low Ambient Controller and one (1) compatible condenser fan motor for changeout. • Sizes 090-121 require one (1) Low Ambient Controller and one (2) compatible condenser fan motor for changeout.

LOW AMBIENT CONTROLS (SIZE 150 ONLY) MASTER PRICES

ODS ORDERING NUMBER / FAST#

DESCRIPTION APPLICATION USAGE

HD52AK002 / 1178268 Outdoor Fan Motor - Required on units with Motormaster V

150 Size 208/230-3-60

460-3-60

HD52GE577 / 1178269 Outdoor Fan Motor - Required on units with Motormaster V 150 Size

575-3-60

CRLOWAMB030A00 Motormaster® V Low Ambient Kit. Mechanical cooling operation down to -20° F (- 29° C)

150 Size 208/230-3-60

CRLOWAMB031A00 Motormaster® V Low Ambient Kit. Mechanical cooling operation down to -20° F (- 29° C)

150 Size 460-3-60

CRLOWAMB032A00 Motormaster® V Low Ambient Kit. Mechanical cooling operation down to -20° F (- 29° C).

150 Size 575-3-60

• FAST / RCD List Price - Subject to change on a quarterly basis and should be verified with RCD prior to quoting.