OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS

Transcript of Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015...

Page 1: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

OSMIUMHIGH DENSITY FIBER OPTIC CHASSIS

Page 2: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

OSMIUM

THE OSMIUM SYSTEM

The Osmium high density fiber optic chassis is based upon a modular and scalable system composed of 19’’ unloaded chassis, blades and cassettes. It is designed to meet the challenges of data centers where high density and competitive costs are critical parameters.

• Up to 45% more LC port density per rack unit than the best equivalent

• Scalable, the Osmium chassis capacity can be can be configured to changing needs

• Manageable, it enables easy moves, adds and changes

• Superior transmission performance thanks to the MPOptimate low loss technology

1RU unloaded chassis

2RU unloaded chassis

4RU unloaded chassis

Blade(to be loaded with 5 micro-cassettes)

Blank blade

Micro-cassette Blank cassette

• Pre-terminated and tested• OM3 – OM4• Straight or Flipped• 1 x 12 Fiber MPO

• 6 x LC duplex

CH

AS

SIS

B

LAD

ES

CA

SSE

TT

ES

HIGH DENSITY FIBER OPTIC CHASSIS

Page 3: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

Most high density fiber solutions for data center offer up to 144 LC ports (or 72 LC duplex) per rack unit. Thanks to the slimline design of its micro-cassettes and blades, the Osmium high density fiber optic chassis delivers a density of 210 LC ports (or 105 LC duplex) per rack unit in its 2RU or 4RU versions. The 1RU version offers a density of 180 LC ports.

HIGHER DENSITY MEANS MORE VALUE FOR THE DATA CENTER OWNER

IN THE MAIN DISTRIBUTION AREA

The Osmium chassis’s high density can contribute to a reduction in the number of racks deployed - resulting in reduced floor space usage and associated cost savings. This is achieved while maintaining a system that is simple, efficient and easy to manage.

IN THE EQUIPMENT AREA

(Especially Middle of Row and End of Row design)

The Osmium chassis (1 or 2RU) can be installed above racks therefore optimizing rack utilisation for active equipment. The scalability and modularity of the Osmium chassis enables easy adjustment of capacity to meet varying port density requirements.

* As per April 2015. Based upon Osmium 2RU and 4RU chassis

0

50

100

150

200

250

Best equivalentOsmium

210ports

144ports

45%MORE DENSITY*

UP TO

45% MORE DENSITY THAN BEST EQUIVALENT*

NUMBER OF LC PORTS

PER RU

Page 4: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

SCALABLE AND MANAGEABLE

Easily configured capacity

Thanks to its highly modular design, the capacity of the Osmium chassis can be easily configured to meet changing demands.

Easy to manage

The Osmium chassis has been designed to enable easy moves, adds and changes. Each blade has it’s own integrated cable management system offering easy access to LC ports when extracted from the chassis. Parts designed to be moved have an orange color for easy identification.

A magnetic ID label, housed on the front fascia, is compatible with laser printing for a simple and effective port identification.

The white finish on the front fascia contributes to improve visibility in data center environments running with dimmed lights in an energy saving mode.

Osmium MPO trunk cable manager

The Osmium modular MPO trunk cable manager comprises two cable breakout drawers per U, each supporting up to five 24U fiber trunk cables.

Located at the rear of the chassis, the manager can easily be configured to accept incoming trunk cables from either the left, right or both sides, improving flexibility and installation times.

Page 5: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

SUPERIOR TRANSMISSION PERFORMANCE

Osmium LC/MPO micro-cassettes are compatible with the MPOptimate pre-terminated fiber optic solution. As with every MPOptimate connectivity component, the micro cassettes offer superior transmission performances (Attenuation ≤ 0.35dB max., RL ≥ 27dB min) allowing greater flexibility for the cabling infrastructure design.

The MPOptimate system enables up to 6 cassettes per link for 10Gb/s with a full 300 meters support on OM3 fibers and 550 meters on OM4 fibers. It is therefore particularly adapted to cross-connect designs in large data centers.

Distributorin accordancewith ISO/IEC 11801 Network access

cabling subsystemMain distribution

cabling subsystemZone distribution

cabling subsystemEquipment

cabling

Generic cabling system

ENI MD ZD LDP EO

EQP

The MPOptimate system enables up to 6 cassettes per link

SUPERIOR

TR

A

NSMISSION PERF

OR

MANCE

Attenuation≤0.35dB

max.RL≥27dB

min.

Page 6: Osmium High Density Fiber Optic Chassis - IC Intracom › blog › wp-content › uploads › 2015 › 06 › … · Most high density fiber solutions for data center offer up to

Entrance FacilityMain

Distribution Area (MDA)Horizontal and Equipment Distribution Area

Additional InformationFor more information visit te.com/Osmium

te.comMPOptimate, TE Connectivity, TE connectivity (logo) and are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners.

The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.

© 2015 TE Connectivity Ltd. family of companies All Rights Reserved.

320445EU  05/15   Original

BROADBAND NETWORK SOLUTIONS /// OSMIUM

OSMIUM CHASSISAPPLICATIONS IN DATA CENTERS

The added value of Osmium high density fiber optic chassis is particularly relevant for some applications and categories of data center. The table here below identifies for each data center category and for each area of the data center, where we recommend the use of Osmium panels.

MAIN DISTRIBUTION HORIZONTAL & EQUIPMENT DISTRIBUTION

CROSS-CONNECT DESIGN

INTER-CONNECT DESIGN

SMALL ENTERPRISE DATA CENTER UP TO 100 m2 •

MEDIUM ENTERPRISE DATA CENTER 100 – 300 m2

••• •• •LARGE ENTERPRISE

DATA CENTER 300 – 3000 m2 ••• ••• ••

SUPER TECH DATA CENTER

3000 – 50 000 m2 + ••• •••Strongly recommended ••• Recommended •• Applicable •