OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 1 of 50 OIW-EX Series of Oil in Water Monitors Data Logging Handbook Document code: OIW-HBO-0003 Version: EX-002

Transcript of OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code:...

Page 1: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 1 of 50

OIW-EX Series of Oil in Water Monitors Data Logging Handbook Document code: OIW-HBO-0003

Version: EX-002

Page 2: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 2 of 50

Document History 1. Version A Draft...................First draft – separated from

installation and User Handbook 1st May 2007 2. Version B Draft...................Changes to made to in line with

Software Enhancements 20th April 2009 3. Version C Draft...................Preface page updated 12th June 2009 4. Version 1.............................First Release after Review 29th June 2009 5. Version 1a ...........................New Appendix created 20th Aug 2009 6. Version 1b...........................File Location in Windows Vista 21st Aug 2009 7. Version 1c ...........................Differentiate Direct and Remote

Access 4th Sept 2009 8. Version 1d...........................SamTrack Added and Information

About Calibration Added 14th Sept 2009 9. Version 2.............................Updated in line with changes to

Version 4 Software 22nd Jan 2010

Page 3: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 3 of 50

Preface This handbook is part of a library of handbooks that cover the full operation of the OIW-EX Series of products. The table below indicates the handbooks available. Please ensure that you have read all handbooks required for your job function. Note: please ensure you have the latest version of these documents – password protected copies of the documents together with a table of the latest revisions are available on-line at:

http://www.advancedsensors.co.uk/downloads and click on Documents on the left hand side of the screen.

The passwords may be obtained directly from Advanced Sensors Ltd.

Handbooks Descriptions Code Handbook Description OIW EX Model OIW-HBO

100

1000

1000

P

4000

0001 Installation Hardware related details required for the physical installation of the OIW-EX Series of units.

0002 User An overview of the operation of the OIW-EX Series of products and details how to configure the unit.

0003 Data Logging Information on how to access and examine the data log and system log files.

0004 Remote Access

How to control the OIW-EX Series of units remotely.

0005 Spectrometer Operation of the spectrometer and associated Spectrometer files.

0006 Wireless Controller

Set up and use of the handheld wireless controller. O O O O

0007 Flush Valve Operation of the OIW-EX Series of units when a Flush Valve is fitted. O O O

0008 Dual Flow Operation of the OIW-EX Series of units when used in a Dual Flow Mode. O O O

0009 Microscopy Operation of the OIW-EX Series of units with Microscopy files.

0010 Hart Operation of the OIW-EX Series of units with supporting Hart. O O O O

0011 In-Line Probe User

Operation of the OIW-EX Series of units with an In-Line Probe.

0012 In-Line Probe Installation

Installation of the OIW-EX Series of units with an In-Line Probe.

Key

= Required O = Optional

Page 4: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 4 of 50

Table of Contents

1 OIW-EX Series – Data logging Handbook........................................................... 6 1.1 Introduction....................................................................................................6 1.2 Health & Safety..............................................................................................6

2 Log File Locations and Types............................................................................... 7 2.1 Direct Access .................................................................................................7 2.2 Remote Access...............................................................................................7 2.3 OIW Log Files - overview .............................................................................9

3 Data - Log Files .................................................................................................. 13

4 Custom Data Log Files ....................................................................................... 17

5 System Log Files................................................................................................. 19

6 Using LogView................................................................................................... 21 6.1 Starting LogView.........................................................................................21 6.2 Loading a data log File ................................................................................22 6.3 Scaling the PPM level..................................................................................29 6.4 Scaling the Time Axis..................................................................................30 6.5 Viewing Data Log Header Information .......................................................31 6.6 Hiding Individual File Data .........................................................................32 6.7 Viewing Measured Readings Only ..............................................................33 6.8 Viewing Notes and the Data Display...........................................................34 6.9 Viewing Data with Multiple Files Loaded...................................................35 6.10 System Notes and SpAn...............................................................................36

7 SamTrack ............................................................................................................ 39 7.1 SamTrack Overview ....................................................................................39 7.2 SamTrack Interface......................................................................................39

8 Appendix 1 – Retrieving Files Directly from an OIW-EX Series Analyzer ...... 45 8.1 Gaining Direct Access to the OIW PC ........................................................45 8.2 Using the OIW PC .......................................................................................46 8.3 Accessing files on the OIW PC ...................................................................47

9 Appendix 2 – Calibration Procedure................................................................... 48 9.1 Sampling Procedure .....................................................................................48 9.2 Example Results...........................................................................................49

10 Appendix 3 – OIW-EX Series Contact Details................................................... 50

Page 5: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 5 of 50

Symbols in this document The following symbols are used in this document to indicate special information: Warning – an instruction that draws attention to the risk of injury or death. Caution – an instruction that draws attention to the risk of damage to the product, process or surroundings. Note – Clarification of an instruction or additional information. Information – Further reference for more detailed information or technical details.

Page 6: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 6 of 50

1 OIW-EX Series – Data logging Handbook

1.1 Introduction

This handbook relates to Version 4 and above of the Advanced Sensors Software for the OIW-EX Series. Please contract Advanced Sensors or your agent for Handbooks that relate to previous versions of the Advanced Sensors Software for the OIW-EX Series There are two ways to access the log files for the OIW-EX Series

1. Directly from the OIW-EX Monitor’s PC (this will require physical access to the EX Monitor’s PC), or

2. Remotely from a Desktop/Laptop PC via Ethernet. This data logging handbook provides user information on how to locate the data log files, an overview of the data within the log files and how to view the data. The Advanced Sensors’ Software described here is free to use in conjunction with Advanced Sensors’ Analyzers.

CAUTION: This manual describes the data logging features of the unit NOT the installation. Ensure that the unit has been correctly installed in line with the Installation Handbook prior to use. CAUTION: No options should be altered without a full understanding of the change being made.

1.2 Health & Safety

WARNING: This document relates to electrical equipment of substantial weight. Health and Safety section of the Installation Handbook must be read carefully and understood before using this equipment. NOTE: although Warning hazards are related to potential personal injury, and Caution hazards are associated with material damage, it must be understood that operation of damaged equipment could lead to personal injury or death. All Warning and Caution hazards must be complied with.

Page 7: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 7 of 50

2 Log File Locations and Types The log files can be found in a directory called OIWlogs, located in the shared documents area on the system’s drive.

2.1 Direct Access

The path to access data directly, e.g. to copy directly from the OIW to a USB Memory Stick or Thumb drive, is shown below.

• Start My Computer Shared Documents OIWlogs

Figure 1. Direct Access

2.2 Remote Access

Windows XP and Windows Vista each provide slightly different ways of locating the shared documents area.

2.2.1 Windows XP

The path to access data remotely is shown below, see Figure 2.

• Start My Network Places SharedDocs on Oiwsn<serial number of unit> OIWlogs

Figure 2. Location of OIWlogs Directory when using Windows XP remotely

Page 8: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 8 of 50

2.2.2 Windows Vista

The path to access data remotely is shown below, see Figure 3.

• Start Network OIWSN<serial number of unit> SharedDocs OIWlogs

Figure 3. Location of OIWlogs Directory when using Windows Vista remotely

Page 9: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 9 of 50

2.3 OIW Log Files - overview

Within this folder there are three types of sub folders, as shown in below, Figure 5.

Figure 4. OIW log folders

The three types of folders are: • Monthly Data_Logs – these folders contains the data recorded by the unit during the

operation of the unit; • System_Logs – contains the System Logs which holds a summary of key events that

have happened during operation of the unit; • OilType_Backups – contains the backups of Oil types.

Page 10: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 10 of 50

Each Monthly Data log folder may contain three types of sub folders, as shown in below, Figure 5.

Figure 5. OIW log folders

The three folders are: • Data_Logs – contains the primary second by second data logs during the operation of

the unit; • Spec_Logs – this will only be present for the OIW-EX Series units that contain a

Spectrometer1 and contains the spectrometer readings – see Spectrometer Handbook for more details on these files;

• US_Logs – contains the US Logs which holds information relating to the Ultrasonic unit;

All data log files are stored in .csv (Comma Separated Values) file format. This means that they can be viewed with a simple text editor such as NotePad that comes with Microsoft Windows. However, if these files are opened with a program which accepts .csv files (e.g. Microsoft’s Excel, OpenOffice’s Calc etc) then they can be viewed in a tabulated display format.

1 The only Advanced Sensors OIW-EX Series unit that does not contain a Spectrometer is the OIW-EX100.

Page 11: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 11 of 50

2.3.1 Log Files - Filename format

The file “SN00038-05_Mar_09-08_07_58_Thu_OIW_Data.csv” may be used to show the filename format,

SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The serial number of the OIW unit, in this example SN00038 SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The date the spectra was taken, in this example 5th March 2009 SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The time the Data Log was created, in this example 08:07:58 SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The day of the week the Data Log was created, in this example

Thursday SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The type of OIW file, in this example Data Log for an Oil-in-Water

sensors SN00038-05_Mar_09-08_07_58_Thu_ OIW_Data.csv The type of the file. As with all of the OIW data logs the data logs are

text based files output in .csv format (comma separated values). This means that they can be opened in a plain text editor such as Notepad (included with Windows) or more sophisticated mathematical analysis tools such as Microsoft’s Excel application.

Page 12: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 12 of 50

The picture below (Figure 6) shows the same file viewed in both Excel (left) and in Notepad (right).

Figure 6. Data Log Files view in various applications

As the OIW is run on a standard Microsoft Windows XP Pro operating system the user can display the files and arrange the files in a variety of ways. The diagram below (Figure 7) shows examples of some ways the data can be sorted and viewed. It is beyond the scope of this document to detail Windows’ functionality.

Figure 7. Sorting Log files

Page 13: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 13 of 50

3 Data - Log Files Log files are created to capture a comprehensive record of all activities in the system. There are five circumstances for which a new data log file will be created, they are:

1) When the unit starts up; 2) At midnight, a new file is created; 3) At midday (optional – turned off as default); 4) When the configuration is changed and saved; 5) If the system software can’t for any reason write to the current log file. e.g. the

user has deleted the file, moved the file during a backup, or opened the file to view it while the OIW software was trying to open it, then a new file will be created to ensure that no data is lost.

Each data log file filename will start with the Serial Number of the unit being logged, followed by the date and time of file creation, followed by the day of the week (for quick reference) and ending in _OIW_Data, as shown below, Figure 8.

Figure 8. View of log files

Page 14: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 14 of 50

A typical data log file is shown over page, Figure 9. Each data log file consists of two main sections – the configuration data header for the first part of the file, and the data itself, separated by data headings to help identify the data value. The configuration data header information reflects the current unit configuration. If discrepancies start to occur in PPM readings this header allows the user to quickly check what has changed. More importantly, should the systems hard drive fail then (provided the data logs have been backed up regularly) the replacement unit can be quickly re-configured from this header. In the example below the reason this file was created (line 1) was Software Started. By comparing this header with the header from the previous file we can see exactly what was changed and when. Similarly, what software version, how long the laser has been running and what oil type this unit was configured for can all be seen from the configuration header.

Figure 9. Typical Log File output

The data consists of eight columns of information. They are as follows: • Time the time of the reading in Hours, Mins and Seconds; • ppm the PPM value at that time;

Page 15: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 15 of 50

• ppmC the compensated PPM reading (this column will be blank if trending compensation is not enabled, as in the above example);

• Raw the raw florescence value from which the PPM value was derived, • Temp the temperature of the sample chamber; • AvMea the average measured value – this is the average of all the measured seconds

in the current measurement cycle and will be written in the first second after the measurement phase is complete (in the example above, line 52), Note: as the ppm value is latched during measurement the AvMea value will NOT be the average of the ppm values during the measurement phase.

• State – this indicates the measurement cycle phase abbreviated to three letters as below: HOM homogenisation; SET settling; MEA measuring; FLU flushing; HOL holding; FRE frequency tuning; CLO valve closing; OPE valve opening; FLO flowing; CLE cleaning;

• Comments – the last column(s) will occasionally provide additional information. In Figure 9 the word ‘START’ can be seen in this column, this tells the user that someone started the system at that time. Other comments are:

Overall Comments: SW START the software was started;

START the start button was pressed;

STOPPED the stop button was pressed;

Ultrasonics Related Comments: Fset<frequency> the homogenisation frequency was updated to this value;

ATEnd Frequency tuning has ended;

ATAbort Frequency Tuning Abort ;

Measurement Related Comments2:

Spectrometer Related Comments:

2 The Measurement comment reflects the units of measure that the OIW Monitors has been configured for; i.e. if the OIW Monitor has been configure to measure parts per billions then the comments will be PPBalrm, PPBack, PPBclr and PPBOOR respectfully.

PPMalm a ppm alarm was raised;

PPMack a ppm alarm was acknowledged;

PPMclr a ppm alarm was cleared;

PPMOOR ppm value is out of range;

Page 16: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 16 of 50

SPEC READ MANUAL

a spectrum has been generated manually by the user;

SPEC TIMED a spectrum has been generated by a time based trigger;

PPM SPEC TRIGGERED

the measured value has reach a level high enough to trigger the production of a spectrum;

System Related Comments: SYSalm a system log alarm was raised;

SYSack a system log alarm was acknowledged;

SYSclr a system log alarm was cleared;

Waster Status Related Comments: WSalm a water status alarm was raised;

WSack a water status alarm was acknowledged;

WSclr a water status alarm was cleared;

Simulation Related Comments: SIMp ppm value is being simulated;

SIMf raw flu value is being simulated;

SIMt temperature is being simulated;

<R> SPEC READ Spectrometer reading taken. Where R = the reason for the read (MANUAL, TIMED, or <ppm trigger>-TRIG) (OIW-EX1000 units only);

SysMsg-<xxx> System Log written to SysLog file with message xxx, where xxx is a number representing the message written.

More than one of the above messages can occur in any one second; if this happens then each message will be placed in a separate column. When Trending is set to ON then every second of data will be logged to the log file. When Trending is set to OFF then the log file only stores every second of the measurement phase; for all other phases only the start time of that phase is captured (see User Handbook for details on how to turn Trending On or Off).

PPMalm a ppm alarm was raised;

Page 17: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 17 of 50

4 Custom Data Log Files The data logs mentioned in the previous section are fixed and can not be altered. However, to accommodate users who may not want a configuration header, or maybe want a file with only ppm values and a time stamp, the OIW software provides the opportunity to create a secondary ‘custom’ data log. To access the configuration tab for custom data logs type your password, see Figure 10 , and click the “Login” button”, see Figure 10 and click the “Log File Setup” tab, see Figure 12.

Figure 10. Set Custom Data Log Button

Figure 11. Configuration Options

Now click the General Button and select the Custom Log Files tab on the General Configuration window that will appear.

Figure 12. Custom Log file Configuration Options Window

Custom log files are default to disabled – if not required then they will take up unnecessary disk space and should therefore remain off. To enable custom log generation simply select the tick box in the middle left that states Custom Log Files Enabled (Figure 12 ) when this is done the upper section, which is greyed out as default, will become active as shown above.

Page 18: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 18 of 50

Un-ticking the various data columns (Figure 12 ) will disable them from being printed to the custom data log. For example, un-ticking everything except Time and ppm will generate a two column custom data log. Two further options available for the custom data log are Record configuration data at start of file (Figure 12 ) which disables the recording of the configuration data header from the custom log file; and Record Only Measured Values (Figure 12 ) which, if ticked, will exclude all trending data and only display the average measured values. At the bottom of this window is a section marked Data Log Frequency (Figure 12 ). This section has two options 1 file per day (starting at midnight) or 2 files per day day (starting at midnight and midday). Changing this option will affect both the custom data log and the master data log. If 1 per day is selected then a new log file will be generated at midnight every night and will record 86,400 lines of data (as there are 86,400 seconds in a day). If 2 per day is selected then a new log file will be created at midnight and another one created at midday – each holding 43,200 lines of data. This allows users to open data log files in third party programs that have a limit on how many lines they can handle. NOTE: Advanced Sensors LogView program can open a 24 hour data log. Custom data logs will be created in a subfolder on the data folder, their location can be seen in Figure 7.

Page 19: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 19 of 50

5 System Log Files System log files (referred to as SysLogs) record key events that happen during the operation of the software and track any concerns about the normal operation of the unit. These log files allow Advanced Sensors Ltd to be proactive in preventing customer affecting issues during maintenance checks and to diagnose the root cause of a problem should a fault occur. There are two circumstances for which a new SysLog will be created, they are:

1) When the unit starts up. 2) If the system software can’t for any reason write to the current SysLog file.

e.g. the user has deleted the file, moved the file during a backup, or opened the file to view it while the OIW software was trying to open it, then a new file will be created to ensure that no data is lost.

SysLogs can be found in the System sub-folder of the OIWlogs folder, see section 2.Log File Locations and Types. A typical folder is shown below, Figure 13. As can be seen, the format of the file is <date of creation>-<time of creation>_SysLog.csv (note: depending on Microsoft Windows settings the file extension may be hidden, as show in Figure 13.).

Figure 13. System Folder Contents

A typical SysLog file is shown over page, Figure 14. Figure 14 shows the SysLog (file in background) together with the Data log (file in foreground). As can be seen the SysLog file provides a summary of the events in a concise form. In normal operation, where the unit is left to run continuously over a long period of time the SysLog will span months or even years and allows a long term view of the operation of the unit. As the SysLog is a summary file, to save file size, it will not continually log a recurring alarm i.e. in the example below the Valve Anomaly alarm that occur at 15:36:50 and lasted for 11 seconds was only reported once in the SysLog file.

Page 20: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 20 of 50

Figure 14. SysLog File and associated Data File

Should the system software detect a problem in either the hardware or software operation it will log it in the SysLog file and in some circumstances display a message to inform the user via a pop-up window on the screen. As previously mentioned the SysLog file will indicate that an error has been logged. It is strongly recommended that remote Ethernet access is given to Advanced Sensors Ltd so that prompt diagnostics can be performed to minimise downtime.

Page 21: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 21 of 50

6 Using LogView LogView is Advanced Sensors software tool used to view the data log files. Note: as mention previously the files can be view with a variety of tools such as Notepad and analysis can be done in programs like Microsoft’s Excel program.

6.1 Starting LogView

To start LogView simply locate the LogView icon on the desktop, shown below, Figure 15 . Once the software has started the screen will be as shown, Figure 15 .

Figure 15. ASLogView Icon and Startup Screen

Page 22: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 22 of 50

6.2 Loading a data log File

To load a file select the button marked Click to Load Log File highlighted in red, Figure 16 . When this is selected a standard Windows load dialogue box will appear. Simply navigate to the data directory and select a data log file, as shown below, Figure 16 .

Figure 16. Loading a data log File

Page 23: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 23 of 50

When the file loads the red button will change to display the filename it has loaded (Figure 17 ) and the data within that file will be displayed as a chart (Figure 17 ). Two tables; one table for the measure data, (Figure 17 ), and one for System Notes, (Figure 17 ). In addition all buttons and selection options will be enabled (Figure 17 ) (prior to loading a file these options will be greyed out, as seen above Figure 16), and the next button in line (blue button (Figure 17 )) will also become enabled.

Figure 17. Initial View After File Loaded

The table for measure data (Figure 17 ), may be tailored via the Select data to display group of controls, see Figure 18.

Ticking ppmC and un –ticking Temp controls in the Select data to display has updated the table to show ppmC and hide Temp.

Figure 18. Changing the data displayed

Page 24: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 24 of 50

Once the second (blue) button has been enable the process can be repeated to load a second file into LogView – and in turn the third (green) button will be enabled, allowing the user to load a third data log. Figure 19(left) below shows 72 hours worth of data loaded into LogView for easy viewing. The colour of each line on the graph corresponds with the colour of the file name on the load button.

Figure 19. Three Days Logs Displayed

As mention previously, a new data log will be created for various reasons one example being if the user was backing up a data log file and the OIW could not write to it. In these circumstances no data will be lost, as a new data log file will be created with a file name representing the time (and date) of creation. With this in mind, LogView can not only display multiple days but can allow the user to view multiple logs for one day. An example of this can be seen in Figure 19 (right). EXAMPLE EXPLAINED - In this example a data file for unit (serial number) SN00385 was created at midnight, but another file was created at 07:31:53 in the morning. Selecting the View Header button indicates the reason this file was created was “Previous File Locked” as the data logs are backed up every Monday morning (and this is a log file for Monday) it is most likely that this is not any kind of fault condition, but just part of the users backup procedure inadvertently caused the OIW software to start a new file to ensure no data was lost. As can be seen the two files have been loaded into LogView to get a full day view of events. Note: as no ppm data was log in the midnight file after 07:31:52 (red filename/line) the red line will drop to zero ppm after this time. Similarly the 07:31:52 file (blue filename/line) will display zero ppm up until this time – as can be seen in Figure 18 above. See 6.2.1 Several OIW Files on the same day for the Same Analyzer show an alternative way to deal multiple files.

Page 25: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 25 of 50

6.2.1 Several OIW Files on the same day for the Same Analyzer

The example shown above assumes that you wished to open each file individually. In this sub-section we will show how to open a several files for the same unit for the same day in one go and some of the advantages of doing so. In Figure 20 we can see that there are eight files for 15th Jun 2009. If we select any of the files for the 15th and click the OPEN button we will be presented with a dialog box asking whether use all the files for that day, see Figure 21. If you answer Yes to the dialog box show in Figure 21 the results will be as shown on the same chart, see Figure 22 .

Figure 20. Set of Files for the Same Day

Figure 21. Several files on the Same Day

Page 26: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 26 of 50

Figure 22. Having Opened Several Files for the Same Day

The data from all the files are loaded and displayed on the chart, see Figure 22 . The advantage of loading several files at once can be shown because we can see a gap in the chart, see Figure 22 ; the gap was created by a user stopping the Analyzer at 09:04:08, see Figure 22 . The number of files that make up the days data is shown below the Analyzer number and date, see Figure 22 , and headers for each file may be viewed via the View Header button, see Figure 22 .

Page 27: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 27 of 50

When the View Header button is click a window will appear showing the headers, see Figure 23. You may choose amongst the various headers by using the Time the File Started control, see Figure 23 . Only Show Differences checkbox will allow you to focus on the changes, see Figure 23 . All differences are shown in red, see Figure 23 .

Figure 23. Viewing the Headers for Several Files

Use of the Time the File Started control may be seen in see Figure 24.

Figure 24. Viewing the Headers for Several Files – Selecting Headers

Page 28: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 28 of 50

When you check the Only Show Differences checkbox, all lines which are identical across all the headers are hidden, Figure 25.

Figure 25. Viewing the Headers for Several Files – Only Show Differences

Page 29: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 29 of 50

6.3 Scaling the PPM level

As in the example in Figure 17 the default scale of 0-100ppm will not show much detail. The use can scale the ppm axis to provide them with a more detailed view, as shown below, Figure 26.

Figure 26. Enhancing the PPM level

Page 30: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 30 of 50

6.4 Scaling the Time Axis

As with the ppm scale the time axis can also be adjusted. With the scale set to 24 Hours (default scale) a full day can be displayed in the graph area – as previously shown above. This view is compressed – each point on the screen will be made up of several seconds’ worth of data. The user can change the time scale by selecting a time in the drop down box marked Visible Area, Figure 27 .

3 Hour Selection Zoom In Selection

Figure 27. Time Axis Adjustment

By changing the visible area the graph is expanded so that the selected setting is shown in the graph window. For example in Figure 27 the visible area the LogView screen to the left has been set to 3 Hours. This means that at any one time 3 hours worth of data can be seen on the screen at one time. Notice that on this setting (compared to the 24 hour setting of Figure 26) the scroll bar has reduced in size. This has happen because a complete 24 hour graph has been drawn on the graph area. By dragging the scroll bar to the right or the left the complete graph area (24 hours of data) can be seen – 3 hours at any one time. The selection choices are 24 Hours, 12 Hours, 6 Hours, 3 Hours or Zoom In. The final setting (Zoom In) differs slightly to the others (Figure 27 right). When this option is select each point on the graph represents one second of data. As this represents 86,400 points of data, the visible area will cover just 9 minutes. To avoid scrolling excessively the graph area covers only 6 hours of data. There are two methods of displaying data beyond the initial 6 hours. Using the drop down box labelled Set Start Time (Figure 27 )the user can select the start time that the graph is drawn from – for example selecting a start time of 15 Hrs will draw the data from 15:00:00 to 21:00:00 on the graph (with 9 minutes visible at any one time on the screen). Note: the maximum setting in this drop down box is 18 Hrs – the reason being this will produce the final 18:00:00 to 23:59:59 graph. The alternative method of selecting time is to use the increment-decrement arrows (Figure 27 ). Every time these arrows are selected the time line will move along another 1 hour.

Page 31: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 31 of 50

6.5 Viewing Data Log Header Information

The button to the right of the load log file button is named View Header. This button when selected will open a text window that displays the header content, as shown below, Figure 28.

Figure 28. Viewing the data Logs Header Information

Page 32: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 32 of 50

6.6 Hiding Individual File Data

Moving to the right, there is a tick set of tick boxes next to the View Header button – a set of tick boxes being available for each file loaded. The first tick box is labelled Hide Current Plot (Figure 29 ). Ticking this option will remove the line from the graph. Figure 29 shows the first file (red line) has this option ticked and in turn it’s line has been removed from the graph.

Figure 29. Hiding File Data from the Graph

Page 33: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 33 of 50

6.7 Viewing Measured Readings Only

The next tick box is label Show Measure Only, Figure 30 . As can be seen in the graph area of Figure 30 when this option is ticked only the measured results are displayed. Again this option is available for each individual file loaded i.e. in the example below this option is ticked for the blue line only.

Figure 30. Viewing Measured Readings Only

Page 34: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 34 of 50

6.8 Viewing Notes and the Data Display

The next tick box is labelled Highlight Notes, Figure 31 . When this option is ticked if any notes or comments have been written to the file by the OIW software then they will show up as small vertical marks at the top of the graph, Figure 31 - note how each coloured line has its own set of indicators slightly displaced from each other. When the cursor is move over the graph area it turns from the standard pointer to a cross-hair symbol. Clicking the left mouse button on the graph will list the data associated with that point on the graph in the data area at the right of the screen Figure 31 with data in the measured information in the top most table and system notes in the lower table. Note: the amount of data displayed in the data area will up to two hours worth of measuring data and all the system notes that have been loaded. With the highlight notes selected, i.e. with the vertical indicators displayed (Figure 31 ), the user can left click the cursor on these indicators to display the data for that point in time. As can be seen in Figure 31 clicking on the first blue indicator ( ) within the data displayed is a note stating “SPEC TIME” – indicating that time dependant spectra was taken at 00:02:44. If a note can not be found it could be that the user left clicked on the wrong point of the graph. To correct this the user can either left click on anther point of the graph, or they can use the Nudge data arrow buttons (Figure 31 ). With an area of data selected selecting these buttons will ‘nudge’ the data up or down one graph point in time.

Figure 31. Viewing Notes and Data

Page 35: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 35 of 50

6.9 Viewing Data with Multiple Files Loaded

With more than one file loaded clicking on the graph will display data for one file only. The radio button marked Data Line Select (Figure 32 ) allows the user to select which file should be shown in the data box. As well as the radio button displaying which file has been selected the colour of the text in the measurements and System Notes tables will turn the colour of the filename and graph line it is displaying data for (Figure 32 ) and the upper right title will display the words Displaying Data For <filename colour> Line – two examples are shown in Figure 32.

Figure 32. Selecting File Data

Page 36: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 36 of 50

6.10 System Notes and SpAn

The System Notes panel in LogView displays system events that have occurred for the OIW Analyzer, Figure 33 . LogView integrates with SpAn and this will be of benefit to those how have a Spectrometer fitted3. If one or more System Notes are selected, Figure 33 , and that selection includes a System Note showing that Spectrum was generated4 then the Launch Span button will be enabled, Figure 33 . The Launch SpAn button will launch Span with the Spectra files that match the System Note events. You may use the Configure button to inform LogView about the location(s) of the Spectrum files, see Figure 33 .

Figure 33. System Notes and SpAn

3 The only Advanced Sensors OIW-EX Series unit that does not contain a Spectrometer is the OIW-EX100. 4 The following are System Notes that indicate that a Spectrum was generated, PPM SPEC TRIGGERED, SPEC READ MANUAL or SPEC TIMED.

Page 37: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 37 of 50

6.10.1 Spectra Options – The Configure Button

Figure 34. Spectra Options – The Configure Button

When the Spectra Options’ Configure button is clicked LogView searches for all the disk drives that are accessible by the user. LogView presents a dialog box that allows the user to search some or all of these disk drives for Spectra Files. This will allow LogView to find the Spectra files ready for SpAn. The dialog box has two main areas

1. The List of Drives it has found, Figure 34 , and 2. Search Results Area, Figure 34 .

Page 38: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 38 of 50

Figure 35. Spectra Options – The Configure Button – Searching

When the desired disk drives have been selected and the Search Drives button is click LogView will search each of the selected drives for Spectra Files. Figure 35 show the Configure window while searching for files.

a) Selected Drives, Figure 35 and Figure 35 , and b) Search progress, Figure 35 , c) Search Drives button is disabled while the search is in progress, Figure 35 , d) The list of folders LogView has found in the drives the user has selected, Figure 35 , e) Search Results detail, Figure 35 , which shows that Spec_Logs are located in

C:\Documents and Settings\administrator\Desktop\... and f) OK and Cancel buttons; these are disabled until search is complete, Figure 35 and

Figure 35 . When searching has been completed the Search Drives, OK and Cancel button will become enabled and the user will be allowed to check which folders are to be included when LogView attempts to Launch SpAn with Spectra files. The details about which folders are checked are persevered for future use with LogView.

Page 39: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 39 of 50

7 SamTrack 7.1 SamTrack Overview

SamTrack assists with correlating the OIW Monitor with samples that have been sent to a laboratory for analysis; by knowing the time and duration the laboratory sample was taken SamTrack will calculate the average value of the data stored in the OIW data log file. SamTrack is useful when calibrating the OIW Monitor when it is initially commissioned or when the process has changed. See Appendix 2 – Calibration Procedure for information about the Calibration Procedure

7.2 SamTrack Interface

Figure 36. SamTrack’s Interface

Page 40: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 40 of 50

SamTrack interface is divided into four main sections, and these are detailed in the table below Section Name Description Sample Details, Figure 36 , Allow the user to enter the data needed to calculate the sample

average. This Section is always enabled.

Errors and feedback for the user, Figure 36

Informs the user about problems with the details in the Sample Details Area. This Section is always enabled.

Results, Figure 36 Allows the user to Calculate the Sample Average. This Section is only enabled. If the Sample Detail area has enough valid information.

Results File, Figure 36 Allows the user to save the Result to a file for future reference. This Section is only enabled. If the Sample Detail area has enough valid information and a Result has been produced.

SamTrack will only enable the Results area, Figure 36 , if enough information has been entered to allow SamTrack to calculate the Sample Average.

Page 41: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 41 of 50

7.2.1 SamTrack Interface – Sample Details

s Figure 37. SamTrack’s Interface

SamTrack maintains a list of the Serial Number that have been used. You may type in the Unit Serial Number or select from the list provided by the Unit Serial Number drop down list. Feedback relating to the Serial Number is shown in the Errors and feedback for the user area, see Figure 36 . Set Path To Sample Files allows you to specify the path to the files created by the Advanced Sensors’ Analyzer. If the Path To Sample Files has been set for a particular Unit Serial Number then when that Unit Serial Number is selected again the Path To Sample is re-stored. For SamTrack to calculate the amount of oil in the sample you will need to specify the date and time that the sample was taken. The time of the sample may be defined as the start time and the end time or start time and the duration of the sample. Feedback relating to the sample’s date and time is shown in the Errors and feedback for the user area, see Figure 36 . When SamTrack has enough valid information to calculate the amount of oil in the sample the Results section will become enabled, Figure 36 show the Results section in the context. This allows the user to use the Calculate The Sample Average button. See Figure 38

Results Dis-enabled Results Enabled

Figure 38. SamTrack’s Results Dis-enabled and Enabled

7.2.2 SamTrack Interface – Errors and feedback for the user

The Results Section Not Enabled Because: area, see Figure 36 will keep the user informed about the state of the information that SamTrack requires. The Results Section Not Enabled Because: area will be blank if and only if enough valid information has been entered for SamTrack to calculate the amount of oil in the sample.

7.2.3 SamTrack Interface – Results

The Results area is only enabled when enough valid information has been entered for SamTrack to calculate the amount of oil in the sample.

Page 42: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 42 of 50

When the user clicks the Calculate The Sample Average button SamTrack will user the information that has been entered in the Sample Details to Calculate the sample average and results are presented in the area below the Calculate The Sample Average button, Figure 39.

Figure 39. SamTrack’s Results

The Enter LAB result (if known) allows the user to enter the result that has been obtained from the laboratory and this information may be saved.

Page 43: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 43 of 50

7.2.4 SamTrack Interface – Results File

The Results File area is only enabled when enough valid information has been entered for SamTrack to calculate the amount of oil in the sample and a result has been calculated. The Results File area allows the user to save the average calculated by SamTrack and the result recorded by the laboratory in a file for future reference. The Save The Results to a File will prompt the user to select a file if the Current Results File area is blank. SamTrack saves the value in Current Results File and associate it with the OIW Serial Number used ready for use in the future. The Clear The Current Results File Path will clear the value stored in the Current Results File and when the Save The Results to a File is next used it will prompt the user for a file location.

Figure 40. SamTrack’s Results File

Page 44: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 44 of 50

The saved file contains the information entered into the Sample Details area, Figure 36 , and the result from clicking the Calculate The Sample Average button, see Results area, Figure 36 . The file may be opened using any standard spreadsheet program, see Figure 41, or any standard text editor, see Figure 42.

Figure 41. SamTrack’s Results File opened using Microsoft’s Excel

Figure 42. SamTrack’s Results File opened using Microsoft’s Notepad

Page 45: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 45 of 50

8 Appendix 1 – Retrieving Files Directly from an OIW-EX Series Analyzer 8.1 Gaining Direct Access to the OIW PC

NOTE: PLEASE READ ALL SECTIONS BEFORE STARTING.

If you have remote Ethernet access please read the Remote Access Handbook for the most convenient method of access all data. If you do not have network access to the OIW Analyzer you will need to gain direct access to the OIW. With the unit energised (NOTE: a hot work permit may be required) remove the 14 bolts that secure door of the OIW, see Figure 43.

Figure 43. Selecting File Data

Page 46: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 46 of 50

With the door of the OIW open, see Figure 44, you will be able to see and gain access to the OIW PC’s USB sockets shown in the red oval.

Figure 44. OIW with the door open

8.2 Using the OIW PC

Plug the keyboard and trackpad that Advanced Sensors provided with the OIW Analyzer into one of the other spare USB ports.

Plug your USB storage device into one of the spare USB connector on the OIW PC. Please wait while the OIW PC attempts to mount the USB storage device. When the OIW PC has completely finished installing the USB storage device the OIW PC will display the following screen, see Figure 45. The USB storage device will be assigned a “drive letter” by Windows XP, in our case “D:”. The drive letter that Windows XP assigns to your USB storage device may be different.

Page 47: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 47 of 50

Figure 45. OIW PC successfully mounting a USB storage device

8.3 Accessing files on the OIW PC

Now access the required log files and copy the files to the USB storage window. To access files for a specific time period read Section 2 - Log File Locations and Types on Page 7 and to read the detailed description of the format of the filenames produced by the OIW Analyzer see section 2.3.1 - Log Files - Filename format on Page 11 Your understanding of the filename format will assist you in retrieving the right files from the OIW Analyzer.

Page 48: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 48 of 50

9 Appendix 2 – Calibration Procedure 9.1 Sampling Procedure

9.1.1 Important points

In order to ensure that the sample sent to the laboratory is consistent with what the OIW Analyzer has measure the follow points need to be observer.

• It is recommended that the sample point be positioned no more than 1m from the analyzer,

• Samples should be extracted from the sample point during the Flow period of the schedule,

• At least 4-5 samples should be taken over a 12 hour period to complete calibration, and • The Sample should be taken after the OIW Analyzer

9.1.2 Steps

1. When the analyzer is in the FLOW period of the cycle, extract the sample from the sample point over a period of 30-60sec.

2. Record the time when extraction of the sample STARTED and the time when extraction of sample STOPPED.

3. When all samples have been taken use the SamTrack utility to obtain the average ppm value for the extraction period.

NOTE: It is very important that the STARTED and STOPPED Times are taken from the clock on the OIW Analyzer.

9.1.3 Calibration Steps

When all samples for calibration have been analyzed carry out the following: 1. Stop the analyzer cycle using Stop button. 2. Select the Enable Measuring checkbox box in the Measure When Stopped group

under the Oil Calibration Tab of the main menu. 3. Open the flow valve using the Manual Valve Control option Open Flow under the

General Settings Tab of the main menu. 4. Turn on Ultrasonics for 5-10sec using the Ultrasonic IF Tab of the main menu in order

to clean measuring chamber. 5. Wait for 5-10sec. 6. Close the flow valve using the Manual Valve Control option Close Flow under the

General Settings Tab of the main menu. 7. Turn on Ultrasonics for 5-10sec using the Ultrasonic IF Tab of the main menu in order

to homogenize sample in chamber. 8. Wait for 5sec. 9. Record the ppm reading. 10. Multiply this reading by the Average Difference (see examples results below) value

obtained during the sampling procedure. Record this value. 11. Adjust the Gain using the Gain Control under the Oil Calibration Settings Tab of the

main menu until the ppm reading equals the value obtained in step 10.

Page 49: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 49 of 50

12. De-select the Enable Measuring checkbox box in the Measure When Stopped group under the Oil Calibration Tab of the main menu.

13. Select Save Changes & Logout Button to save. 14. Start the analyzer cycle using Start on main menu.

9.2 Example Results

9.2.1 If the OIW Analyzer is measuring Lower than the Lab.

Sample No Lab Reading (ppm) OIW Reading (ppm) (Lab/OIW) 1 3 2 1.50 2 9 4 2.25 3 18 15 1.20 4 27 25 1.08 5 18 14 1.28 Average Difference = 1.46 e.g. if the ppm reading = 55 the new reading should be 55 x 1.46 = 79.7 Now increase the gain to obtain a ppm reading of 79.7.

9.2.2 If the OIW Analyzer is measuring Higher than the Lab.

Sample No Lab Reading (ppm) OIW Reading (ppm) (Lab/OIW) 1 2 3 0.66 2 4 9 0.44 3 15 18 0.83 4 25 27 0.92 5 14 18 0.77 Average Difference = 0.72 e.g. if the ppm reading = 55 the new reading should be 55 x 0.72 = 39.6 Now decrease the gain to obtain a ppm reading of 39.6

Page 50: OIW-EX Series of Oil in Water Monitors€¦ · OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010 Advanced Sensors Ltd, Tel: +44(0)28 9332

OIW-EX Series – Data Logging Handbook Code: OIW-HBO-0003 Version: EX-002 Date: 18 March 2010

Advanced Sensors Ltd, www.advancedsensors.co.uk Tel: +44(0)28 9332 8922. FAX +44(0)28 9332 8669 Page 50 of 50

10 Appendix 3 – OIW-EX Series Contact Details Customer Liaison Sales & Marketing Tel. +44(0)28 93 32 8463 E-Mail: [email protected] Advanced Sensors Headquarters Advanced Sensors Ltd 8 Meadowbank Road Carrickfergus BT38 8YF UK Tel: +44 (0)28 93 32 89 22 Fax: +44 (0)28 93 32 86 69