Virtual Computing Platform Specifications
Visit www.nutanix.com for more information. Follow us @nutanix Email [email protected]
Block Specifications
NX-1000 Series | NX-1050
Per Node (4 per Block)
Dual Intel Sandy Bridge E5-2620, 12 cores / 2.0 GHz
Configurable; 64 GB or 128 GB
2x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45
UL, CSA, CE, VCCI, KCC, C-Tick
400 GB SSD, 4x 1 TB HDDs
* 1 vCPU, 2 GB Memory, Windows 7 optimized, VCAI clones
Server Compute
Memory
Network Connections
Certifications
VM Density
Storage Capacity
Block Dimensions
Block Weight
System Cooling
Operating Environment
Thermal Dissipation
Operating Requirements
NX-2000 Series | NX-2000 / NX-2050
Per Node (4 per Block)
Dual Intel Xeon X5650 processors 12 cores / 2.66GHz
Configurable; 48 GB, 96 GB, or 192 GB
1x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45
UL, CSA, CE, VCCI, KCC, C-Tick
Up to 75 Virtual Desktops (Knowledge Workers*)Up to 50 Virtual Desktops (Knowledge Workers*)
365 GB SSD, 300 GB SSD 5x 1 TB HDDs
400 GB SSD, 300 GB SSD 5x 1 TB HDDs
Height: 3.5 (88mm), Width: 17.2 (437mm), Depth:26.75 (679mm)
85 lbs. (38.6kg) stand-alone / 95 lbs. (43kg) package / 7 lbs (3.2kg) node
4x80mm heavy duty fans with PWM fan speed controls
Op Temp Rng: 50-95F (10-35C) Non-Op Temp Rng: 32-110F (0-43C) Op Humidity Rng (non-condensing): 20-95% Non-Op Humidity Rng: 5-95%
4600 BTU/hr maximum, 3750 BTU/hr typical
Input Voltage: 100-240V AC auto-range Input Frequency: 50-60Hz
NX-3000 Series | NX-3000
Per Node (4 per Block)
Dual Intel Sandy Bridge E5-2660, 16 cores / 2.2 GHz
Configurable; 128 GB or 256 GB
2x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45
UL, CSA, CE, VCCI, KCC, C-Tick
Up to 80 Virtual Desktops (Knowledge Workers*)
Height: 3.5 (88mm), Width: 17.6 (447mm), Depth:28 (711mm)
72.8 lbs. (33kg) stand-alone / 101 lbs. (45.8kg) package / 7 lbs (3.14kg) node
4x80mm heavy duty fans with PWM fan speed controls
Op Temp Rng: 41-95F (5- 35C) Non-Op Temp Rng: -40- 149F (-40- 65C) Op Humidity Rng (non-condensing): 20-80% Non-Op Humidity Rng: 5-95%
4605 BTU/hr maximum, 3920 BTU/hr typical
Input Voltage: 200-240V AC auto-range Input Frequency: 50-60Hz
NX-3000 Series | NX-3050 / NX-3051
Per Node (4 per Block)
Dual Intel Sandy Bridge E5-2670, 16 cores / 2.6 GHz
Configurable; 128 GB or 256 GB
2x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45
UL, CSA, CE, VCCI, KCC, C-Tick
Up to 100 Virtual Desktops (Knowledge Workers*)
2x 400 GB SSD 4x 1 TB HDDs 2x 800 GB SSD 4x 1 TB HDDs
Height: 3.5 (88mm), Width: 17.25 (438mm), Depth:26.75 (679mm)
Height: 3.5 (88mm), Width: 17.25 (438mm), Depth:26.75 (679mm)
67.2 lbs. (30kg) stand-alone / 77.2 lbs. (35kg) package / 7 lbs (3.2kg) node
67.2 lbs. (30kg) stand-alone / 77.2 lbs. (35kg) package / 7 lbs (3.2kg) node
4x80mm heavy duty fans with PWM fan speed controls4x80mm heavy duty fans with PWM fan speed controls
Op Temp Rng: 50-95F (10-35C) Non-Op Temp Rng: -40-158F (-40- 70C) Op Humidity Rng (non-condensing): 20-95% Non-Op Humidity Rng: 5-95%
Op Temp Rng: 50-95F (10-35C) Non-Op Temp Rng: -40-158F (-40- 70C) Op Humidity Rng (non-condensing): 20-95% Non-Op Humidity Rng: 5-95%
4610 BTU/hr maximum, 3750 BTU/hr typical 3930 BTU/hr maximum, 3410 BTU/hr typical
Input Voltage: 180-240V AC auto-range Input Frequency: 50-60Hz
Input Voltage: 100-240V AC auto-range Input Frequency: 50-60Hz
NX-6000 Series | NX-6050 / NX-6070
Per Node (2 per Block)
Dual Intel Sandy Bridge E5-2670, 16 cores / 2.6 GHz
Dual Intel Sandy Bridge E5-2690, 16 cores / 2.9 GHz
Configurable; 128 GB or 256 GB
2x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45
UL, CSA, CE, VCCI, KCC, C-Tick
Up to 100 Virtual Desktops (Knowledge Workers*)
Up to 110 Virtual Desktops (Knowledge Workers*)
Height: 3.5 (88mm), Width: 17.25 (438mm), Depth:29.6 (752mm)
64.8 lbs. (29.4kg) stand-alone / 75.8 lbs. ( 34.4kg) package / 7.7 lbs (3.5kg) node
4x80mm heavy duty fans with PWM fan speed controls
Op Temp Rng: 50-95F (10-35C) Non-Op Temp Rng: -40-158F (-40- 70C) Op Humidity Rng (non-condensing): 8-90% Non-Op Humidity Rng: 5-95%
Power Supply (Dual supply/block)
1.1kW Out @100-140V, 13.5-9.5A, 50-60HZ; 1.4kW Out @180-240V, 9.5-7.0A, 50-60Hz
1.1kW Out @100-120V, 12.0-10.0A, 50-60HZ; 1.62kW Out @180-240V, 10.5-8.0A, 50-60Hz 1.4kW Out @200-240V, 9.6A, 50-60Hz 1.62kW Out @180-240V, 10.5-8.0A, 50-60Hz 1.62kW Out @180-240V, 10.5-8.0A, 50-60Hz
Power Consumption 1150W maximum, 1000W typical 1350W maximum, 1100W typical 1400W maximum, 1150W typical 1350W maximum, 1100W typical900W maximum, 700W typical
1100W maximum, 900W typical
3070 BTU/hr maximum 2400 BTU/hr typical
3750 BTU/hr maximum 3070 BTU/hr typical
Input Voltage: 180-240V AC auto-range Input Frequency: 50-60Hz
400 GB SSD, 300 GB SSD, 5x 1 TB HDDs 2x 400 GB SSD 4x 4 TB HDDs
2x 800 GB SSD 4x 4 TB HDDs