Performance testing of a novel F ibre Optic based vortex flow meter
‘Smart Flow’in high pressure wet steamin high pressure wet steam
R. Jansen, TNO, The NetherlandsJ. Golliard, TNO, The NetherlandsC. Staveley, Smart Fibres Ltd, UK
W. Schiferli, Shell, The NetherlandsA. Znotins, Shell, Canada
by
![Page 2: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/2.jpg)
Content
• Market need• The solution
– Measurement principle– Test results Air/Water (water wet air)– Test results Air/Water (water wet air)– Test results Wet steam (condensed steam)
• Conclusion• Way forward
![Page 3: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/3.jpg)
Market need
• Availability of a cost-effective solution for permanent flow and quality monitoring
• of steam injected into steam injection wells• of steam injected into steam injection wells
• using specific advantages fibre optic sensing
![Page 4: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/4.jpg)
Solution; combination of:
• Existing principle, vortex meter ; – Proven technology– Robust and low cost
• Fibre Optic (FO) sensing element;– Implemented existing FO architecture– Using specific advantages of FO
![Page 5: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/5.jpg)
Vortex meter principle
• Vortex shedding behind bluff body• Shedding frequency linear to flow velocity
U velocity
Strouhal number
D
USrf 0=
velocity
bluff body diameterVortex shedding frequency
![Page 6: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/6.jpg)
Fibre Optic Vortex Meter
![Page 7: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/7.jpg)
Fibre Optic (FO) Element
• FO sensor inside vane
• Fibre Bragg Grating (FBG)
• Reflected wavelength varies
with strain (and temperature)with strain (and temperature)
Alternating bands of high and low refractive index
![Page 8: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/8.jpg)
Multiplexing
FBG Sensors
![Page 9: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/9.jpg)
Measured parameters
Vortex shedding
peak
Mechanical eigenfrequency
vane
Required d ynamic range : > 2500 Hz
![Page 10: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/10.jpg)
Test result single phase gas
![Page 11: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/11.jpg)
Performance two phase flow?
• Gas hold -up– actual gas velocity increases– also known as ‘over reading’
• Possible interference liquid layer• Possible interference liquid layer• Presence of droplets:
– in the flow near the vortex meter– deposited on the shedder bar
![Page 12: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/12.jpg)
Expected Flow regimeS
uper
ficia
l liq
uid
velo
city
[m
/s]
In surface steam pipelines
Superficial gas velocity [m/s]
Sup
erfic
ial l
iqui
d ve
loci
ty [
m/s
]
![Page 13: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/13.jpg)
Two clear mechanisms
Based on experiments:• Interference liquid layerquality factor vortex shedding
-3dB
width
vortex
• Droplets changing the effective gas densityShift in mechanical eigenfrequency
3dB-f ∆= v
vp
fQ
![Page 14: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/14.jpg)
Test results two phase
Wet steamAir/water
![Page 15: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/15.jpg)
Test results air/water
![Page 16: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/16.jpg)
Air only (no water)
![Page 17: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/17.jpg)
Liquid hold-up (quality factor)
![Page 18: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/18.jpg)
Liquid hold-up (mech. eigenfr.)
![Page 19: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/19.jpg)
Test results wet steam
![Page 20: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/20.jpg)
Dry Steam
![Page 21: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/21.jpg)
Wet steam test conditions
0.6
0.8E
ntra
ined
fra
ctio
n [-
]
40 bar80 bar120 bar
0 5 10 150
0.2
0.4
True Usg [m/s]
Ent
rain
ed f
ract
ion
[-]
![Page 22: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/22.jpg)
Actual steam vapor flow
The measured vortex shedding frequency is translated to a vapor flow rate:• Assuming single phase gas• Using measured steam quality (based on • Using measured steam quality (based on
the vortex peak quality factor)• Known liquid hold-up based on two phase
flow simple model (derived from OLGA)• Assuming two phase flow to calculate the
(corrected) actual vapor flow rate
![Page 23: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/23.jpg)
Assuming single phase flow
40
60(m
easu
red-
refe
renc
e)/r
efer
ence
[%
] SteamQuality < 0.98
0 5 10 15-20
0
20
True Usg [m/s]
Err
or(m
easu
red-
refe
renc
e)/r
efer
ence
[%
]
![Page 24: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/24.jpg)
Known quality & simplified model
10
20(m
easu
red-
refe
renc
e)/r
efer
ence
[%
] SteamQuality < 0.98
0 5 10 15-20
-10
0
True Usg [m/s]
Err
or(m
easu
red-
refe
renc
e)/r
efer
ence
[%
]
![Page 25: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/25.jpg)
Measured quality (quality factor)
![Page 26: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/26.jpg)
Assuming two phase flow using:Measured quality & simplified model
0
10
20(m
easu
red-
refe
renc
e)/r
efer
ence
[%
]
0 5 10 15-30
-20
-10
0
True Usg [m/s]
Err
or(m
easu
red-
refe
renc
e)/r
efer
ence
[%
]
![Page 27: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/27.jpg)
Conclusions wet steam
High steam quality (>0.98) errors in flow:• less than 3% for velocities above 7 m/s• between 2 and 7 m/s errors less than 5%
Lower steam qualities (<0.98) errors in flow: • increased to 60% without correction• With steam quality correction :
– less than 10% for velocities above 7 m/s– between 2 and 7 m/s less than 20%
![Page 28: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/28.jpg)
Way forward
Test performance under field conditions:• Steam tests only covered ‘end of life’ field
conditions in Shell Canada• No (affordable) test rig can deliver such high flows• Bench mark field test: steam test separator
Mature and further validate technology:• Test robustness current algorithms field conditions • Improve current algorithms to reduce steam
quality errors down to +/- 10% (currently +/- 20%)
![Page 29: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/29.jpg)
Back-up slides
• Slide 30: Over-reading as function of XLMSame plot as shown in slide 23
• Slide 31: Measured steam quality taken into account field conditions Shell Canada (Usg > 7 m/s). field conditions Shell Canada (Usg > 7 m/s). Note: Nominal field velocities (10 < Usg < 15 m/s)
![Page 30: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/30.jpg)
Assuming single phase flowOver Reading versus XLM
Wet gas region0 XLM < 0.3
![Page 31: NSFMW Performance testing of a novel fibre optic based ... · PDF filePerformance testing of a novel Fibre Optic based vortex flow meter ‘Smart Flow’ in high pressure wet steam](https://reader031.fdocuments.net/reader031/viewer/2022013014/5a9dce357f8b9a96438cae69/html5/thumbnails/31.jpg)
Measured quality (quality factor)Usg > 7 m/s (field conditions)
error lines +/- 20%