North Elevation South Elevation - Government of Jersey North Elevation South Elevation East...

North Elevation South Elevation - Government of Jersey North Elevation South Elevation East Elevation
download North Elevation South Elevation - Government of Jersey North Elevation South Elevation East Elevation

of 1

  • date post

    11-Jul-2020
  • Category

    Documents

  • view

    3
  • download

    0

Embed Size (px)

Transcript of North Elevation South Elevation - Government of Jersey North Elevation South Elevation East...

  • Photo A Showing location of proposed new shelter

    ;··>'1 1N•ne:o1i!ghbouring Property

    Existing bus stop markings burnt off.

    Plan

    Section of footpath planter broken out. New macadam hardstandlng formed.

    Roadside guardrailing maintained and altered - central section to be removed

    Bus stop markings relocated

    D

    IDIDI

    La Route des Quennevais

    Roadside guardrailing modified

    Clear footpath width maintained

    1300

    Clear footpath iil width maintained ~

    0 1 2 3

    I I I I I I I I I I

    UNEAR SCALE 1 :50

    4 5n

    New prefabricated bus shelter in accordance with manufacturers

    All dimensions are to be checked on site before the commencement of any works including the order of materials. Any discrepancies are to be reported to the Architect. Do not scale from this drawing. Unless the title 'Contract' or 'Working' has been added to these drawings then these drawings are not for site use and we will accept no responsibility for errors or omissions, the drawing will also not be adjusted to include for SER requirements. This drawing is design copyright© Andrew Harvey Architects Ltd. Digimap Licence Number J48. Portions of this drawing may include intellectual property of the States of Jersey and are herein used by permission.

    Date: Revision Note:

    3 Bay Fully Enclosed Bus Shelter Specification:

    Description: Dome Roof/3 Bay/Full End Panels/2 Front Openings

    Dimensions: 1300mm Wide x 3000mm Long x 2500mm High

    Seating: Length of Shelter/ 700mm from Ground Level

    Glazing: Roof - Bronze Tinted Polycarbonate Sides - 6mm TSG

    Colour: Dark green framing

    /"/--7"'- details ~~7 1300 (!~

    Bus stop markings relocated

    Clear footpath width maintained

    a

    La Route des Quennevais

    North Elevation South Elevation

    East Elevation New prefabricated bus shelter in accordance with manufacturers dela"ls

    New prefabricated bus shelter in accordance with manufacturers details

    Section of footpath planter broken out. New macadam hardstanding formed.

    Bus stop marldngs relocated

    ===-- --=== === === === ===' === ===

    3000 ~· 7100 (Section of Railings Removed)

    West Elevation

    dient

    States of Jersey Transport & Technical Services

    project title

    New Bus Shelter at Stop No. 2542 (Don Farm) La Route des Quennevais

    St. Brelade

    drawing tltle

    Layout Plan, Elevations, Site Plan &

    scale(s):

    1:50/1:100

    Photo

    Consultation

    date: drawn:

    April 2016 R.M checked:

    Andrew Harvey Architects DDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

    1st Floor, Beresford House, Bellozanne Road,

    St. Helier, Jersey, JE2 3JW

    telephone: 01534 869291 facsimile: 01534 869293

    drawing number:

    11s1 I 01 I 02

    mobile: 07797 740530 enquiries@aha.co.je