normas quipment-solutions-guide

76
volume 39 issue 19 TEST & MEASUREMENT Rental Solutions Guide techrentals your rental business partner YEARS

description

normas

Transcript of normas quipment-solutions-guide

Page 1: normas quipment-solutions-guide

volume 39 ● issue 19

T E S T & M E A S U R E M E N T

Rental Solutions Guide

techrentalsyour rental business partner

Y E A R S

Page 2: normas quipment-solutions-guide

1800 632 [email protected]

Offi ce Locations

TechRentals Australia

Adelaide169 South RoadRidleyton South Australia 5008P 08 8302 8800 | F 08 8302 8899

Brisbane72 Donaldson RoadRockleaQueensland 4106P 07 3717 9100 | F 07 3077 8872

DarwinUnit 3, 101 Coonawarra RoadWinnellie Northern Territory 0820P 08 8947 2860 | F 08 8947 2901

Melbourne18 Joseph StreetBlackburn North Victoria 3130P 03 9896 3000 | F 03 9896 3099

NewcastleUnit 2, 1 Hartley DriveThornton New South Wales 2322P 02 4966 5910 | F 02 4966 3586

Perth 122 Kewdale RoadKewdale Western Australia 6105P 08 9441 3900 | F 08 9441 3999

Sydney41 Enterprise CircuitPrestons New South Wales 2170P 02 8777 0800 | F 02 8777 0877

TownsvilleUnit 2, 14 Blackhawk BoulevardThuringowa Central Queensland 4817P 07 4773 7788 | F 07 4723 5397

TechRentals Malaysia

603 5632 1135www.techrentals.com.my

SELANGOR D.E38 Jalan PJS 11/3 Bandar Sunway46150 Petaling JayaSelangor Darul EhsanMalaysiaP +60 3 5632 1135 F +60 3 5632 5409

TechRentals New Zealand*

0800 832 475www.techrentals.co.nz

AUCKLAND669 Great South RoadPenrose Auckland New ZealandP +64 9 589 2030 F +64 9 589 2031

*distributor of TechRentals Australia

TR VMS (Calibration - Repair - Sales)

BRISBANE 72 Donaldson RoadRockleaQueensland 4106P 07 3717 9100 F 07 3717 9148

SYDNEY41 Enterprise Circuit Prestons New South Wales 2170P 02 8777 0800 F 02 8783 5171

PENANG1-10-07, Suntech @ Penang Cybercity (1264)Lintang Mayang Pasir 311950 Bayan BaruPenang P +60 4 619 2641F +60 4 619 2643

Page 3: normas quipment-solutions-guide

Contents

Your trusted partner in technology. Offering innovative solutions through our leading brands: techrentals vidcom telecom

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 43.

Visit TechRentals WikiThis resource centre provides manuals, technical information and how-to videos.www.techrentals.com.au select Technical Tips and Videos.

1. stretch your budgetTest equipment is often used just some of the time. Rental allows you to pay for it only when you use it, as well as stretching your budget by accessing more equipment than you could if you purchased it outright.

2. utilise operating expenseTest equipment is expensive often sitting on a shelf collecting dust – not an effective use of your valuable business capital. Rental allows you to free up cash for other parts of the business where it can be used to generate additional profi ts.

3. conduct product research before purchasingIt is not always clear immediately which make and model will fulfi l your requirements best. Trialling it on casual rental gives you hands-on experience to guide purchase decisions.

4. recover costs more quicklyGenerally rental payments are fully tax deductable and the expense can be recovered far more quickly than the tax allowances for ongoing asset depreciation.†

5. eliminate running costsThe expense of maintaining, calibrating and warehousing your test and measurement equipment can be high. With rental you avoid these costs, as well as freeing up storage space within your premises.

6. cost allocation is simplifi edRental payments are easy to track and account for in your business, making it easy to allocate appropriate costs to departments, clients or specifi c projects.

7. respond to sudden demandsAt peak periods, for unexpected projects, or when essential equipment breaks down, rental can put the necessary equipment in your hands ensuring seamless operations.

8. apply new technologies & avoid obsolescenceRental allows you to update your equipment in line with other businesses and take advantage of new technologies. It also avoids the potential cost of owning equipment that can be quickly superseded.

9. preserve creditRenting avoids the potential cost of utilising credit facilities such as an overdraft or credit cards, which are often used for equipment purchases.

10. technical supportWhen you rent from TechRentals you’ll have the support of an experienced team of product experts, who’ll help you get the most from your equipment. And in the unlikely event of equipment failure we will do our utmost to rectify the issues as soon as possible.†Please ensure you obtain independent professional taxation advice.

Why rental makes good sense General Index 2, 3 & 4

Manufacturers Index 5, 6 & 7

Electronics 8-13

Radio Frequency 14-19

Data &Telecommunications 20-23

Electrical Power 24-37

General Industrial & Process Measurement 38-51

Physical Measurement 52-57

Construction, Building Services & Survey 58-62

Environmental, OHS, Chemical & Laboratory 63-69

Other Products 70

hirecom

1

Page 4: normas quipment-solutions-guide

General Index

AAC See Electrical Power

AC Sources/Inverters/Generators 36

Accelerometer 55

Adhesion Tester 52

Air

Flow 58, 59, 65

Quality 58, 59, 65

Air Balancing Hood 58

Air Conditioner Valve Balancing 59

Air Conditioning

Coolant Flow 69

Electronic Manifold 59

Measurement 58

Valve Balancing 59

Ventilation Meter 59

Air Conditioning & Air Flow 58

Air Quality

Monitoring 58, 63, 64, 65

Particles 64, 65

Pressure & Humidity 58, 65

Air Quality & Heat Stress 65

Airborne Dust & Particle Meter 64

Alignment 42, 55

Anemometer 58, 59

Antenna & Cable Test 16

Antennas 19

Appliance Tester 25

Area Heat Stress 65

Audio Analysers 18

BBalances 55, 69

Balances & Scales Below 8kg 69

Balancing Machinery 59

Balometer 58

Barometric Loggers 68

Bath

Constant Temperature 42

Ultrasonic 50

Battery Management Systems 36

Blast Loggers 56

Body Vibration Measurement 55, 56

Bore Hole Water Quality 67, 68

Borescopes 41

Bridge LCR 10

CCable

Fault Locator 24

LAN Test 20

Locator 20, 24, 61

Tester 20

Cable & Fault Locators 61

Cable & Pipe Tracers & Fault Locators 24

Cable Analysers 20

Cable Locators 61

Calibrators

Current 11, 42, 45

Current Loop 11, 42, 44, 45

Dry Block Temperature 42, 45

Electronic 11

Fitting Set 44

Hydraulic 42, 43, 45

Industrial 42, 45

Intrinsically Safe Loop 43

Laboratory 45

Loop 42, 45

Pneumatic Instruments 42, 45

Pressure 42, 43, 44, 45

Process 42, 44, 45

Resistance 11, 42, 44, 45

Temperature 42, 45

Voltage 11, 42, 44, 45

Camera

Endoscope 41

High Speed 41

Pipe Inspection 41, 61, 62

Thermal Imaging 39, 40

Video 41

Carbon Dioxide (CO2) 50, 63, 65

Carbon Monoxide & Nitrogen Dioxide Monitors 63

Carbon Monoxide (CO) 50, 63, 64, 65

Cat 5, 5E, 6 20

Charge Amplifi er 55

Chart Recorders 45, 49

Chemical & Analytical 69

Circuit Breaker Analyser System 34, 35

Circuit Breaker Testers 34

Circuit Tracer 24

Clamp-on Sensors 31

Clean Room Monitor 64

Cleaver - Fibre Optic 23

Coating Thickness 52, 54

Combustion Gas Analysis 50

Combustion, Flue & Industrial Gas Analysers 50

Communication Test Sets 16, 18

Compressor Output

Flow 65

Quality 65

Concrete Cover Meters 59

Concrete Hardness Testers 60

Concrete Testing

Adhesion 52

Corrosion 60

Cover Meters 59, 60

Moisture Meters 62

Reo Depth 60

Test Hammer 60

Concrete Testing Equipment 59

Concrete Thickness Gauges 59, 60

Conductivity & Salinity 68

Confi ned Space Entry 63, 64

Construction, Building Services & Survey 58

Air Conditioner Valve Balancing 59

Air Conditioning & Air Flow 58

Concrete Testing Equipment 59

Distance Measurement & Surveying 62

Ground Penetrating Radar 61

Material Moisture Meters 62

Pipeline & Cavity Inspection 61

Underground Services Location 61

Utility Leak Detection 61

Counting Scales 55, 69

Crane Scales 54, 55

Current

Clamp 28, 30, 31, 32, 36

DC Source 10

Injection 35

Input Logger 47

Loop 42, 44, 45

Meter 28, 31, 49, 69

Primary Injection 35

Probe 10, 24, 31, 32

Secondary Injection 35

Transformer (CT) 31

Current Clamps Probes & Accessories 31, 32

Current Injectors 35

Current Transformer Testing 34

DData & Telecommunications 20

Cable Test 20

DSL/POTS Test Set 22

Ethernet Analysers 20

Ethernet Loopback 20

Ethernet Test Set 20

Etherscope 20

Fibre Optic Launch Cables & Patch Leads 23

Fibre Optics 23

Fusion Splicers 23

LAN Analysers 20

LAN Cable Testers 20

LAN/WAN Analysers 20

Light Source 22

Light Sources & Power Meters 22

OTDR & Fibre Inspection 23

PDH/SDH Analysers 21

Permanent Link Adaptors 20

WAN Analysers 20

Data Loggers 47, 48

DC High Voltage 10, 31, 32, 33

DC Power Supplies 10

DC Power Supplies & Loads 10

Decade Resistance Box 11, 45

Demand Analysers 27

Dewpoint 65

Digital Storage Oscilloscopes 8, 10

Dissolved Oxygen 67

Distance Measurement 62

Distance Measurement & Surveying 62

Distortion Analysers 18

Dry Block Calibrators 45

DSL/POTS 22

DSn/PDH Ethernet Analyser 22

Ductor 25, 27

Dust Measurement 64, 65

EE & H Field Strength Meters 11

E1/E3 Tester 21, 22

Earth Leakage 25, 32, 33, 34

Earth Testers 25

Electrical Cable Test 25, 32, 33, 34

Surge Generator 24

TDR 24

Electrical Installation & Test

Appliance Tester 25

Earth Leakage (RCD) 25, 32, 33, 34

High Voltage Test (Hipot) 32, 33

Insulation Oil Tester 33

Insulation Test 24, 25, 32, 33, 34

Resistance Test 25, 27, 32

Soil/Ground Resistance 25

VLF Testers 33

Electrical Power 24

AC Sources/Inverters/Generators 36

Battery Management Systems 36

Cable & Pipe Tracers & Fault Locators 24

Circuit Breaker Testers 34

Current Clamps Probes & Accessories 31

Current Injectors 35

Electrical Testers 24

Insulation Testers & Meggers to 20kV 32

Micro-Ohm Meters & Earth Testers 25

Oil, Hipot & VLF Testers above 20kV 33

PAT Testers & RCD Testers 25

Power Analysers & Recorders 27

Power Transformers & Variacs 36

Protection Relay Testing Systems 35

Transformer Testers 34

Electrical Power Generation & Transmission

Current Injection 35

High Voltage Test (Hipot) 33

Power Quality 24, 27, 28, 30, 31

Protection Relay Test 34, 35, 36

Electrical Power Quality

Harmonics 24, 27, 30, 31

Power Factor 24, 27, 30, 31

Power Logger 28

Power Quality Analysers 27, 28, 30, 31

Electrical Power Sources

Battery Management Systems 36

Current Injectors 35

Programmable 36

Electrical Testers 24

Electrical Transducers 24

Electrochemistry 67

Electrometers 8

Electronic Calibrators 11

Electronic Load 10

Electronics 8

DC Power Supplies & Loads 10

Digital Storage Oscilloscopes 8

E & H Field Strength Meters 11

Electronic Calibrators 11

EMC & Power Disturbance Simulators 12

Function Generators 10

Gauss/Tesla Meters 11

LCR Meters 10

Multimeters& Electrometers 8

Probes & Accessories 10

Spectrum Analysers - Low Frequency 11

TV Test Equipment 11

Electrostatic Charge Measurement 8

Electrostatic Meters 8

EMC & Power Disturbance Simulators 12

EMC Test Equipment 12

EMC/EMI Test Equipment 12

Endoscopes 41, 61

Endoscopes Borescopes Visual Inspection 41

Environment, OHS, Chemical & Laboratory

Air Quality & Heat Stress 65

Airborne Dust & Particle Meters 64

Balances & Scales below 8kg 69

Chemical & Analytical - General 69

Environmental Gas & Vapour Meters 63

Environment Flow Meters 69

Floor Slip Testers 67

Laboratory Instruments, Spectroscopy 69

Light Meters, UVA/B/C Measurement 68

2

Page 5: normas quipment-solutions-guide

General Index cont’d.

Moisture & Humidity Meters 65

Noise & Sound Analysers 65

Personal Gas & Vapour Monitors 64

Radiation Monitoring & Protection 66

Water Quality, pH Meters & Electrochem 67

Weather Stations 68

Environmental , OHS, Chemical & Laboratory 63

Environmental Chambers/Ovens 50

Environmental Flow Meters 69

Environmental Gas & Vapour Meters 63

Environmental Noise 65

Environmental Noise Loggers 65, 66

Environmental Test Chambers/Ovens 50

Ethernet Loopback 20

Ethernet Test Set 20

Excavator Cable Locators 61

FFault Locators 24, 61

Fault Loop Impedance Tester 25

Fibre Inspection & Test Kit 23

Fibre Inspection-Capture Probe 23

Fibre Optic Launch Cables & Patch Leads 23

Fibre Optics 23

Cleaver 23

Fibrescope 61

Field Strength Meters 11

Flaw Detector 52

Floor Slip Testers 67

Flow Hood 58

Flow Meters 49, 50, 69

Compressed Air 49

Doppler 49, 50

Gas 49

Liquid 49, 50, 69

Non-Intrusive 49, 50

Open Channel 49, 69

Transit Time 49, 69

Ultrasonic 49, 50, 69

Flow Meters for Liquids & Gases 49

Flue Inspection 41, 62

Force Gauges 54

Formaldehyde Meters 63

Frequency Counters 14

Frequency Response Analysers 34

Function Generators 10

Fusion Splicers 23

GGamma Radiation 66

Gas 63

Carbon Dioxide (CO2) 50

Carbon Monoxide (CO) 50

Flammable (LEL) 63, 64

Formaldehyde 63

Hydrogen Sulphide (H2S) 63, 64

Methane (CH4) 63

Nitric Oxide (NO) 50

Nitrogen Dioxide (NO2) 50

Oxygen (O2) 50, 63

Ozone (O3) 63

Petroleum Hydrocarbons 63

Refrigerant 63

SF6 64

Sulphur Dioxide (SO2) 63

VOC 63, 64

Gas & Vapour Meters 63

Gas Analysis & Monitoring 50, 63, 64

Gauss/Tesla Meter 11

General Industrial & Process Measurement 38

Combustion, Flue & Industrial Gas Analysers 50

Data Loggers 47

Dry Block Calibrators 45

Endoscopes Borescopes Visual Inspection 41

Environmental Test Chambers/Ovens 50

Flow Meters for Liquids & Gases 49

High Speed Video Inspection Cameras 41

High Speed Waveform Recorders 46

Industrial Process Calibrators 42

Infrared Thermal Imaging Cameras 39

Laser Rotational Shaft Alignment 42

Pressure & Humidity Transducers 49

Pressure Vacuum Gauges/Recorders 49

Strip Chart Recorders 45

Tachometers/Stroboscopes 41

Temperature Meters/IR Thermometers 38

Ultrasonic Baths 50

Ground Penetrating Radar 61

HHardness Testers 52

Harmonics (Power) 27, 28, 31

Hart Communicators 43

Heat Stress 65

High Frequency Spectrum Analysers 14, 16

High Speed Video Cameras 41

High Speed Video Inspection Cameras 41

High Speed Waveform Recorders 46

High Voltage Insulation Dielectrics Test Set 33, 34

Hipot Testers 32, 33

Holiday Detector 52

Hot Wire Anemometer 58, 59

Humidity

Chamber 50

Concrete 59

Indoor Air 65

Logging 47, 48

Natural Gas 65

Thermohygrograph 65

Transducers 49

Weather 68

HVAC & IAQ 58, 59, 65

Hybrid Recorders 46

Hydraulic Pressure 42, 43, 52

IIlluminance Meter 68

Inclinometers 54

Indoor Air Quality 65

Industrial Process Calibrators 42, 45

Infrared Cameras 39, 40

Infrared Thermal Imaging Cameras 39

Infrared Thermometers 38

Injection Test Sets 35

Instrumentation Amplifi ers 45, 46

Insulation Diagnostic Analysers 34

Insulation Testers 25, 32

Insulation Testers & Meggers to 20kV 32, 33

Intrinsically Safe

Current Loop Calibrators 42

Gas Monitors 63, 64

Moisture Analysers 65

Photo-Ionisation Detector (PID) 63, 64

IR Thermometers 38

LLaboratory Ovens 50

LAN

Analysers 20

Cable Certifi cation 20

Cable Testers 20

LAN Analysers/Management 20

LAN Cable Testers 20

LAN/WAN Analysers 20, 21

Landfi ll Gas Monitors 63

Laser

Distance & Speed 56, 62

Laser Pipe Alignment System 42

Laser Rotational Shaft Alignment 42

LCR Meters 10

Leak Detectors

Gas Pipe 61, 63, 64

Microwave Oven 66

Refrigerant 63

Water 61

Light Measurement 62, 68

Light Meters, UVA/B/C Measurement 68

Light Source 22

Light Sources & Power Meters 22

Linear Position Transducers 54

Liquid Flow Loggers 69

Liquid Flow Meters 49

Load Cells 54

Logger

Accessories 47

Autoclave 47

Data 47, 48

Explosion 56

Flow 49

Humidity 47, 48

Temperature 47, 48

Loggers See also Recorders

Low Frequency Spectrum Analysers 11

Luminance Meter 68

Lux Meter 68

MMachinery

Balancing 55

Vibration 55, 56

Magnetic Field Meters 11

Manometers 58, 59

Material Hardness Testers 52

Material Moisture Meters 62

Material Testing 69

Memory Recorders 46

Metal Detectors 70

Methane Monitors 63

Micro-Ohm Meters 25, 27

Micro-Ohm Meters & Earth Testers 25

Microwave Leakage Detectors 66

Microwave Oven Survey Meters 66

Modifi ed Atmosphere

Packaging Test 50, 63

Moisture

Concrete 62

Timber 62

Wood 60

Moisture & Humidity Meters 65

Moisture Analysers 65

Moisture Balance 69

Multimeters 8

Multimeters & Electrometers 8

NNatural Gas 65

Network Analyser

Antenna & Cable Test 16

Cable Test 16

Power 27, 30

RF 16

Network Analysers 16

Network Analysers/Antenna & Cable Test 16

Noise & Sound 65

Noise & Sound Analysers 65

Noise Loggers 65, 66

Non-Destructive Testing (NDT) 52, 54

OOccupational Health & Safety 63

Air Quality 58, 59, 65

Appliance Testing 25

Confi ned Space Entry 63, 64

Floor Slip Testers 67

Formaldehyde 63

Heat Stress 65

Lighting 68

Noise & Sound 65

Ozone 63

Radiation 12, 66, 67

UV Exposure 68

Vibration 55

Volatile Organic Compound (VOC) 63

Oil Insulation Testers 33, 34

Oil, Hipot & VLF Testers Above 20kV 33

Optical Power Meter 22

Oscilloscopes

Digital Storage 8, 10

Portable 8

OTDR 23

OTDR & Fibre Inspection 23

Oven 50

Oxygen & CO2 Analysers 50, 63, 64

Oxygen (O2) 50, 63, 64

Ozone (O3) 63

PPancake Load Cell 55

Particle Counters 64

PAT 25

PAT Testers & RCD Testers 25

PDH Analysers 21

PDH/SDH Analysers 21

Permanent Link Adaptors 20

Personal Gas & Vapour Monitors 64

Petrochemical Contamination 63

pH Measurement 67

pH Meters 67

pH reading for Meat Standards 67

pH, mV & Temperature Measurement 67

Photo-Ionisation Detector (PID) 63, 64

3

Page 6: normas quipment-solutions-guide

General Index cont’d.

Physical Measurement 52

Force Gauges 54

Inclinometers 54

Load Cells 54

Material Hardness Testers 52

Non-Destructive Testing 52

Position Transducers 54

Speed Measurement 56

Vibration Analysis 55

Weighing & Counting Scales Over 8kg 55

Pinhole Detector 52

Pipe Locators 61

Pipeline & Cavity Inspection 61

Pipeline Camera Inspection System 61

Pipeline Inspection 41

Pitot Tube 58

Probes & Accessories 10

Portable Appliance Testers 25

Position Transducers 54

POTS 22

Power See Electrical Power

Power Analysers 27

Power Analysers & Recorders 27, 28

Power Demand Analysers 27

Power Disturbance 24, 27, 30, 31

Power Loggers 28, 31

Power Meter - RF 18

Power Meters 18

Power Meters & Sensors 18

Power Supplies - DC 10

Power Transformer Testers 34

Power Transformers 36

Pressure

Calibrator 42, 43, 44, 45

Circular Chart Recorder 49

Indicator/Gauge 49

Logging Gauge 49

Transducers 49

Pressure & Humidity Transducers 49

Pressure Calibrators 44

Pressure Recorders 45

Pressure Transducers 44

Pressure Vacuum Gauge/Recorders 49

Primary & Secondary Test Systems 34, 35

Probes

Current 10, 24, 31, 32, 36

High Voltage 10

Line Logic 46

Process Calibrators 44, 45

Profi bus 44

Prospecting Metal Detectors 70

Protection Relay Test 34, 35, 36

Protection Relay Testing Systems 35

Pulse Porosity Detectors 52

Pumps 42, 43, 45

RRadar Speed Gun 56

Radiation Monitors 12, 66, 67

Radiation Monitoring & Protection 66

Radio Frequency 14

Antennas 19

Communication Test Sets 16

Distortion Analysers 18

Frequency Counters 14

Network Analysers/Antenna & Cable Test 16

Power Meters - RF 18

RF Accessories 19

RF Amplifi ers 19

RF Attenuators 19

RF Signal & Sweep Generators 14

Spectrum Analysers - High Frequency 14

Radiometers 68

RCD Test 25, 32

Recorders 47

Chart 45, 49

Hybrid 46

Memory 46

Pressure 45, 49

Refrigerant Leak Detection 63

Relay Test 35, 36

Resistance

Calibration 11, 42, 45

Decade 11, 45

Ground/Soil 25

Micro-Ohm 25, 27

Static 32

Tester 25, 32, 33, 34

RF See also Radio Frequency

RF Accessories 19

RF Amplifi ers 19

RF Attenuators 19

RF Signal & Sweep Generators 14

RF Sweep Generators 14

Rotating Balancing 55, 56

RTD Calibrator 42

SSafety Bolt Inspection System 54

Salinity & Conductivity 68

Scales 54, 55, 69

Scopemeters 8

SDH Analysers 21

Security

Metal Detectors 70

Security Equipment 70

Sensors - RF 18

Shaft Alignment 42, 55

Shaker Table 55

Signal Generators 14

RF 14

Smoke Generating Machine 58

Soil Resistivity 25

Sound

Dose Meter 66

Measurement 65

Signal Analysis 65

Sound Level Meter 55, 56, 65, 66

Vibration 55, 56

Spectrophotometer 69

Spectroscopy 69

Spectrum Analysers

High Frequency 14, 16

Low Frequency 11

RF 11, 14, 16

Spectrum Analysers – Low Frequency 11

Spectrum Analysers – High Frequency 14

Speed Measurement 56

Splicer - Fibre Optic 23

Startup Current 28, 30, 31, 32

Static Discharge Generators 12

STM1 ... STM64 21, 22

Strip Chart Recorders 45

Stroboscope 41

Surge Generators 24

Surge Transient Generator

EMC/EMI Test 12

Sweep Generators 14

TTachometers 41

Tachometers/Stroboscopes 41

Tan Delta Measurement 33, 35

TDR 24

Telecommunications 20, 21

Access Tester 21

Analysers 21

CDMA 18

Data Tester 21

PDH 21

POTS 22

SDH 21

Temperature

Humidity Loggers 48

IR Thermometers 38

Logging38

Probe 38

Thermocouple 38

Thermometers 38, 39

Temperature Bath 45

Temperature Meters 38

Temperature Meters/IR Thermometers 38

Tension 54

Test & Tagging 25

Test Chambers 50

Thermal Imaging Cameras 39, 40

Thermocouples 38

Thermohygrograph 65

Thickness Gauges 52

Time Domain Refl ector

TDR 24

Torque Wrench 54

Total Dissolved Solids (TDS) 68

TPH Monitor 63

Tracking Generator 14

Transducers

Electrical 24

Humidity 49

Position 54

Pressure 49

Temperature 49

Transformer Testers 34

Transient Burst 12

Transport

Inclinometers 54

Turbidity 67, 68

TV Analyser 11

TV Test Equipment 11

UUltrafi ne Particle Counter 64

Ultrasonic Baths 50

Ultrasonic Probe 52

Underground Services Location 61

Utility Leak Detection 61

UV Exposure 68

VValve Balancing (Air Conditioning) 59

Variacs 36

Vehicle Volume & Speed Counters 56

Ventilation Meters 59

Vibration

Accelerometer 55

Analyser 55, 56

Blast Logging 56

Table 55

Whole Body 55

Vibration Analysis 55

Vibration Loggers 56

Video

Endoscope 41

High Speed 41

Pipeline Inspection 41, 61

Viscometer 69

Visual Inspection 41, 61, 62

Visual Inspection Equipment 41

VOC Monitors 63

Volatile Organic Compounds (VOC) 63, 64

Voltage Calibrators 42, 45

WWalk Through Metal Detectors 70

WAN Analysers 20

Water

Conductivity 68

Depth 49, 67, 68, 69

Depth Measurement 67

Flow 49, 50, 69

pH 67

Quality 67

Sampling 67

Water Quality, pH Meters & Electrochem 67

Water/Oil Bath Temperature Calibrators 42

Water/Oil Temperature Bath 45

WBGT 65

Weather 68

Weather Stations 68

Weighing & Counting Scales Over 8kg 55

Wet & Dry Block Calibrators 45

Wind Speed & Direction 59, 68

Wind Turbine Lightning Protection Test Lead Set 27

Winding Transformer Meter 34

Wood & Masonry Testing

Moisture Meter 60

Workplace Safety See Environmental & OHS

XX-Ray Measurement 66

4

Page 7: normas quipment-solutions-guide

ABACUSABA,301 64

ABBABB,CB2000 24

ACTERNAACT,MTS8000 21

ADVANTESTADV,TR1720 19

ADV,U3771 14

AERQUALAER,500L 63

AGILENT(Also see Hewlett-Packard)

AGI,DSOX3024A 8

AGI,MSO6104A 8

AGI,MSOX3024A 8

AGI,N9304A 14

AGI,N9344C 14

AGI,N9344C-TG 14

AH SYSTEMSAH,ANTENNA 19

AH,SAS-200/550 19

AH,SAS-200/571 19

AH,SAS-571 19

AICAIC,SG-AST-500 54

AIRMAGNETAIR,AIRMAG SPEC AN 14

AIRFLOWAIR,AV2-NATA 58

AIR,PITOT-36 58

ALNORALN,EBT-721-A3 58

ALN,EBT-731 58

AMETEKAME,CADET-25N 54

AME,PPCE 42

A&D MERCURYAND,FC-10K 55

AND,FG-150KB 55

AND,FS-15KA 55

AND,HF-300G 69

AND,HP-40KA 55

AND,MX50 69

ANRITSUANR,50-30-18 19

ANR,ANTENNA 19

ANR,CMA4500SM-MM 23

ANR,MA2104A 18

ANR,MS2711A 14

ANR,MS2712E 14

ANR,MS2721A 16

ANR,S331D 16

ANR,S331E 16

ANR,S332D 16

ANR,S332E 16

ANR,S332E-CMAP-MOD 16

ANR,S820D 16

ANR,WAVEGUIDE-ADAP 16

ANTANT,OMNIDIRECTIONAL 19

AQUAAQU,SNAKEEYE3 61

ARCHOSARC,AV500 61

ARLARL,EL-316 65

ARL,NGARA 65

ATLASATL,TCS-60 55

AUSTRALIAN RECTIFIERSDIM,D201P 36

VAR,D-283-OB 36

BARLOBAR,MTC-150 54

BAR,STC-10000 54

BAR,STC-500NATA 54

BAURBAU,DPA75 34

BEAMEXBEA,MC5 42

BEA,MC5-IS 42

BEA,MC6 42

BELLBEL,4190 11

BEL,5180 11

BIDDLEBID,550005 34

BIRDBIR,43 18

BIR,ELEMENT-HF 18

BIR,ELEMENT-LF 18

BRUEL & KJAERBK,2238E-NATA 66

BK,2239A-NATA 66

BK,4448-IS-3KIT 66

BW HONEYWELLBW,BUMP 64

BW,GA-SPAK 64

BW,MICROCLIP 64

CASELLA CELCAS,MICROTHERM 65

CHAUVIN ARNOUXCHA,PROBE-I 10

GRIDSENSECHK,CK1 31

CHK,CK5 31

CHK,CR100 31

CHK,CR500 31

CHK,PM20 27

CHK,PM30 27

CHK,PM30PLUS 27

CHK,PM35 27

CHK,PM40PQA 28

CHK,PM45 28

CHROMACHR,61501 PAC-PS 36

COM-POWER CORPORATIONCOM,AH-118 19

CRYSTAL ENGINEERINGCRY,NVISION-30-NATA 42

CRY,XP21-100-NATA 49

CRY,XP21-300-NATA 49

CRY,XP2I CAL KIT 1 42

CRY,XP2I CAL KIT 345 43

CRY,XP2I CAL KIT 7 43

CRY,XP2I-10K 49

CRY,XP2I-10K-NATA 49

CRY,XP2I-1K-NATA 49

CRY,XP2I-3K 49

CRY,XP2I-3K-NATA 49

CSCOPE INTERNATIONALCSC,CATXDSGA-KIT 61

CSC,CATXDSGV-KIT 24

CSC,CATXDSGV-KIT 61

CONCEPT SMOKE SYSTEMSCSS,COLT4 58

DATATAKERDE,CANGATE 47

DE,DT600 47

DE,DT80 47

DE,DT800 47

DE,DT80M 47

DE,DT85 48

DEFELSKO CORPORATIONDEF,POS-200ADV 52

DEF,POS-6000 52

DEF,POSITEST 52

DETECDET,DH-50-KIT4 70

DILLIONDIL,ED2000-5K 54

DIL,EDX-20T-NATA 55

DRANETZ-BMIDRA-BMI,PG4400 28

DRA-BMI,PX5 28

DRA-BMI,TR2501 31

DRA-BMI,TR2510 31

DRUCKDRU,DPI104-350 43

DRU,DPI603-2 43

DRU,DPI603-20 43

DRU,DPI610-2 43

DRU,DPI610-20 43

DRU,DPI610-20-NATA 43

DRU,DPI610-2-NATA 43

DRU,DPI610-400 43

DRU,DPI610-400-NATA 43

DRU,DPI615-20-NATA 43

DRU,DPI705 58

DRU,DPI705-IS 58

DRU,PTX1400-25 49

DRU,PTX1400-600 49

DRU,PV411A 43

DRU,UPS III-IS 43

EA TECHNOLOGIESEAT,ULTRATEVPLUS 32

ELCOMETERELC,331-B 59

ELC,331-SH 60

EMERSONEME,375 43

EME,475 43

ENIENI,604L 19

ETMETM,9900 48

EXCALIBEREXA,1000 70

EXFOEXF,AXS-200_850 20

EXF,PPM352_FIP400 22

EXFO,ETS-1000L 20

EXFO,FTB-860G 20

EXFO,PPM350B 22

FIBREOPTICFIB,LAUNCH MM 50UM 23

FIB,LAUNCH MM 62.5UM 23

FIB,LAUNCH SM 9UM 23

FIB,MTFS15-1000 41

FITFIT,HP 44

FIT,LP 44

FITELFIT,S123M12 23

FIT,S178_S325 23

FIXTURELASERFIX,DIRIGO 42

FIX,PAT 42

FLEXIMFLE,G608 49

FLIR SYSTEMSFLI,E60 39

FLI,T390 40

FLUKEFLU,1587 32

FLU,1623-KIT 25

FLU,1625-KIT 25

FLU,1630-EARTH CLAMP 25

FLU,1653 32

FLU,1735 28

FLU,199C-SCOPEMETER 8

FLU,2042 24

FLU,289 FLUKEVIEW 8

FLU,28II-EX 8

FLU,345 28

FLU,376 31

FLU,435 28

FLU,481 66

FLU,52-2 38

FLU,54-2B-FVF 38

FLU,5500A 11

FLU,5500A-NATA 11

FLU,576 39

FLU,700P08-70BAR 44

FLU,700P31-690BAR 44

FLU,700PD6-7BAR 44

FLU,718-300G 44

FLU,719-100G 44

FLU,719-30G 44

FLU,725 44

FLU,725-NATA 44

FLU,726 44

FLU,743B 44

FLU,744 44

FLU,773 45

FLU,789 PROCESSMETER 45

FLU,80K-40 10

FLU,80TK 38

FLU,810 55

FLU,87-5 8

FLU,9141-NATA 45

FLU,9150-NATA 45

FLU,9170 45

FLU,9170-R-NATA 45

FLU,990DSL 2/2+ 22

FLU,DSX-5000 20

FLU,DTX1800 20

FLU,DTX-MFM2 20

FLU,DTX-OTDR 20

FLU,DTX-PLA 20

FLU,DTX-SFM 20

FLU,DTX-SFM2 20

FLU,EI-162BN 25

FLU,ETHERSCOPE-EX 20

FLU,FTK1000 22

FLU,FTK150 22

Manufacturers Index

5

Page 8: normas quipment-solutions-guide

FLU,I5SPQ3 31

FLU,OPTIFIBER-PRO Q 23

FLU,OPTIFIBER-PRO-MM 23

FLU,OPTIVIEW-GIG 20

FLU,Ti25 40

FLU,Ti32 40

FLU,Ti32_WIDE-ANGLE 40

FLU,TiR32 TELEPHOTO 40

FLU,VR1710 28

FOUIER SYSTEMSFOU,DAQPRO-2 48

FUJIKURAFUJ,FSM60R-CT30 23

FUJ,FSM60S-CT30 23

FUJ,FSM70S 23

FUTEKFUT,IHH500-20T 55

FUT,IHH500-2T 55

GARRETTGAR,CS5000 70

GEGE,DYNAMIC 52

GEOTECHGEO,GEM5000 63

GLOI ABGLO,ALISENSOR 54

GLOBAL WATERGLO,FP111 69

GENRADGR,1433-20 11

GR,1433B-NATA 11

GR,1433F-NATA 11

GRANTGRA,GR150-S5-NATA 45

GTI SPINDLEGTI,IPAD3VAB 55

GUTERMANNGUT,AQUASCOPE3 61

HARTHAR,1523-NATA 39

HEALTH PHYSICS INSTRUMENTSHPI,CYPHER5000 66

HEWLETT-PACKARD (Also see Agilent)

HP,33120A 10

HP,33220A 10

HP,33250A 10

HP,34401A 8

HP,35670A 11

HP,53181A 14

HP,5350B 14

HP,6675A 10

HP,8449B 19

HP,8494/5B 19

HP,8494B-8495B 19

HP,8495B 19

HP,8495D 19

HP,8648D 14

HP,8648D-1E5 14

HP,8753D 16

HP,8903B 18

HP,E4418B-001 18

HP,E9300A 18

HP,E9300B 18

HP,ESG-D4000A 14

HIGH VOLTAGE INCHIV,PFT1003 33

HIV,PFT503 33

HILTIHIL,PS1000 60

HIL,PS20 60

HIL,PS200 FERROSCAN 60

HIL,PS38 60

HIL,TESTER4 54

HIOKIHIO,3169-21 CT500AMP 28

HIO,3169-21CLAMPONPT 30

HIO,3169-21CT1000AMP 28

HIO,3196-PQA 30

HIO,3196PQA-CT1000A 30

HIO,3197PQA 30

HIO,3198 31

HIO,3283 24

HIO,3284 31

HIO,3285 31

HIO,3290 31

HIO,3404 41

HIO,3423 68

HIO,3455HVIT-5KV 32

HIO,3551BATTERYTEST 36

HIO,3641-20 48

HIO,3641-20-KIT 48

HIO,8421-01 48

HIO,8421-51 48

HIO,8422-51 48

HIO,8835-HD520 46

HIO,8841 46

HIO,8842 46

HIO,8860 46

HIO,8870-20 46

HIO,8938 46

HIO,9306 46

HIO,9320 46

HIO,9321 46

HIO,9322-KIT 48

HIO,9335 46

HIO,9660CT100A 31

HIO,9661 CCT-500A 31

HIO,9661-01 CCT-500A 32

HIO,9667-FCT-5000A 32

HIO,9669-CCT-1000A 32

HIO,9694CT5A 32

HIO,9725 46

HIO,LCR 3532-50 10

HIPOTRONICSHIP,880PL 33

HOLADAY INSTRUMENTS (USA)HOL,HI-3604 11

HOL,HI-3627 11

HUBER & SUHNERSUH,SUCOFLEX-104PE 19

HV DIAGNOSTICSHVD,HVA TD60 33

HVD,HVA30-DC/VLF 33

HVD,HVA60-DC/VLF 33

HVD,HVA90_DC-VLF 34

HYDRAMOTION LTD UKHYL,V700S-21 69

HYDROLABHYD,MS5 67

HYDROLOGICAL SERVICESHYS,OSSB1 69

IFRIFR,2945B 16

IFR,3500A 18

IkeGPSIKE,300PRO 62

INTERNATIONAL LIGHTILI,1400ABC 68

ION SCIENCEION,GASCHECK3000 63

ION,GASCHECKG3 63

ISCOISCO,6712 67

JACOBS RADIOJRC,NJJ-95B 60

JDSUJDSU,ANT5-STM16 21

JDSU,ANT5-STM4 21

JDSU,CSC-ETHERTR-PC 21

JDSU,EDT-135 21

JDSU,FIBER_INSPECT 23

JDSU,MTS-4000-FCOMP 23

JDSU,OLA-55 22

JDSU,OLP-55 22

JDSU,OLS-55 22

JDSU,SMARTCLASS 22

JDSU,SMARTCLASS-E1-D 22

JDSU,SMARTCLASS-ETH 21

JOFFRAJOF,CTC-1200A 45

JOF,CTC-650A 45

JOF,DPC-1000-NATA 45

KINGFISHERKIN,KI28010_2600 22

KIN,KI78010-7600 22

KIN,KI7822B-7600A 22

KONICA-MINOLTAMIN,CL-200 68

KRAUTKRAMER GMBH & COKRA,DYNAPOCKET 52

KYORITSU ELECTRICKIK,TOS-5101 32

LAPLACELAP,SA1000 12

LINEARLIN,LSPC-1 55

MADGE TECH INCORPORATIONMAD,ULTRASHOCK-EB 55

MARCONIMAR,6910 18

MAR,6912 18

MAR,6913 18

MAR,6920 18

MAR,6923 18

MAR,6970 18

MAR,PSCI424-585 24

MCE LASERSMCE,LS140G 42

MECMESINMEC,AFG-1000NALC 54

MEC,TW60 54

MEGGERMEG,CAL300 34

MEG,DET2/2 25

MEG,DET20C 25

MEG,DET4TC2 25

MEG,DLRO10 27

MEG,DLRO-100LEAD 27

MEG,DLRO10X 27

MEG,DLRO200 27

MEG,DLRO600 27

MEG,DLRO-LEADSET 27

MEG,IDAX300 34

MEG,MIT1020-10KV DIT 33

MEG,MIT1025 33

MEG,MIT525 33

MEG,MOM2 27

MEG,MPP1002-FAULT PP 24

MEG,MTO330 34

MEG,OTS80PB 34

MEG,RCDT330 25

MEG,S1-1052 10KV-DIT 33

MEG,S1-552 5KVDIT 33

MEG,TDR2000/2RM 24

MEG,TM1760 34

MEG,TTR320-47 34

PRO,TORKEL-840 36

PRO,TXL870 36

MELMEL,M5-200 54

METRELMET,IT3017INSTALTEST 25

METRIXMET,MX2040 31

MONARCH INSTRUMENTSMON,PALMSTROBE 41

MON,PHASER 41

MON,PLT200-KIT 41

MORITEXMOR,PALMSCOPE 41

MULTIAMPMUL,MS-2 35

NARDANAR,8217 66

NAR,NBM-520 12

NAR,NBM-550 12

NAR,RADMAN 67

NOVATECHNOV,1637-5 50

NTI AUDIONTI,NT-DAS 66

NTI,XL2+M2210 66

OLDHAMOLD,MX21-SO2 63

OLSON INSTRUMENTS INCOLS,CTG 60

OLYMPUSOLY,38DL 52

OLY,D790-SM 52

OLY,EPOCH600 52

OLY,IPLEX-LT 3.5 41

OLY,IPLEX-LT 7.5 41

OLY,IPLEX-LX 41

OLY,IPLEX-MXII 41

OLY,ISPEEDLT 41

PAN,26MG 52

OMICRONOMI,CMA156-6PCA 35

OMI,CMC256-6 35

OMI,CMC256PLUS 36

OMI,CMC356 36

OMI,CMC356_61850 36

Manufacturers Index cont’d.

6

Page 9: normas quipment-solutions-guide

OMI,CMGPS 36

OMI,CPC100PTS 35

OMI,CPCB2 35

OMI,CPCU1 35

OMI,C-PROBE1 36

OMI,CPSB1 35

OMI,CPSTEP 35

OMI,CP-TD1 35

OMI,CTANALYZER 34

OMI,FRA 34

OTTOTT,KL010-150 67

PANAMETRICSPAN,C-LP-40NM 50

PAN,C-PT-10HB 50

PAN,GC-RL302 49

PAN,GC-RL319 49

PAN,OKS 50

PAN,PM880 65

PAN,PT878 49

PAN,PT878E 50

PAN,PT878GC-01 49

PAN,PT878T 50

PCWPCW,DC30 52

PCW,P40-PULSE 52

PETROSENSEPET,PHA-100 63

PHANTOMPHA,53550 56

PHENIX TECHNOLOGIESPHE,BK130 34

PHOTOVACPHO,2020PRO 63

PHYNIX GMBH & COPHY,SURFIX FN 54

POLYSONICSPOL,HYDRA-SX30-2 50

PPM TECHNOLOGIESPPM,FORM400 63

PROCEQPRO,2000-ND 60

PRO,EQUOTIP 52

PRO,PROFOSCOPE 60

PRO,RESIPOD 60

PRO,SIL-UN 60

PROFOUNDPRO,VIBRA 55

PRO,VIBRA-PLUS 56

PROGRAMMA ELECTRIC AB (Sweden)

PRO,SVERKER760 36

PROMAXPRO,HD RANGER 11

PRO,PRODIG-5 11

PROTIMETER

PRO,MMS-PLUS 60

PRO,SM 62

PRUFTECHNIKPRU,AL12.116 42

PRU,ROT-PROEX 42

PRU,ROT-ULTRA 42

QUESTQUE,2400 66

RAE SYSTEMSRAE,MR2000 63

RAE,MR3000 64

RF SYSTEMS LABRFS,VJ-ADV 41

RH SYSTEMSRH,973-SF6 64

RIONRIO,NL-04 66

RIO,NL-32RTA 66

RIO,NL-32RTA-NATA 66

RIO,NL52EX-NX42RT 66

RIO,VA-10 56

RIO,VA-11 56

RIO,VA-12 56

RISER BONDRB,1205T-OSP 24

ROHDE & SCHWARZRS,FSH3-TG 16

RS,FSH3-TG-V 16

RS,NRT 18

ROTOTHERMROT,C105 45

SCHAFFNERSFN,438 12

SFN,MODULA 6100 12

SEVERN SCIENCESSEV,TORTUSII 67

SEWARDSEW,PAC3760 25

SEW,PT-300 25

SEW,XE3760PKIT+ 25

SHORTRIDGESHO,ADM-860 58

SI PRESSURE INSTRUMENTSSI,PC6-20-NATA 45

SI,PC6-35-NATA 45

SI,PC6-700-NATA 45

SMCSMC,PTE-100-C 35

SOFTINGSOF,PROFIBUS-4 44

SONICLEANSON,2000HT 50

SORESENSOR,DCS150-20E 10

SOR,DCS60-50 10

SVANTEKSVA,SV100 56

T&R TEST EQUIPMENTT&R,200A3PHEDIT 35

T&R,CIT 35

T&R,PCU1-SP NLU5000A 35

TEKTRONIXTEK,P6015 10

TEK,TDS3054 8

TEK,THS730A 10

TEK,TPS2014 10

TELWAVEANT,DIRECTIONAL YAGI 19

TESTOTES,175-H1 48

TES,177-H1 48

TES,177-T4 48

TES,319 61

TES,335 50

TES,350XL 50

TES,445 58

TES,635-2 65

TES,645-1 65

TES,845 39

TEXCELTEX,ATM 56

TOPCONTOP,BM-9-2 68

TOP,IM-2D-NATA 68

TOUR & ANDERSONTA,CBI 59

TA,SCOPE 59

TPSTPS,90FL-T 67

TPS,WP-80 67

TPS,WP-80M 67

TPS,WP82 67

TPS,WP-84 68

TPS,WP-88 68

TRTR,12V-BAT-CIG 10

TR,RF-CONN 19

TR,VIBLOG 56

TRIO KENWOODTRI,PD35-20 10

TSITSI,7565 65

TSI,8324 58

TSI,8373 58

TSI,8375 58

TSI,8386A 59

TSI,8520 64

TSI,8520-1 64

TSI,8525 64

TSI,8530 64

TSI,8530-ENC 64

TSI,8530-ENC-S 64

TSI,8533 64

TSI,8554 65

TSI,8705 59

TSI,8710 59

TSI,9535 59

TSI,9555 59

TSI,9565A 59

TSI,AM510 65

TSI,TA465A 59

UE SYSTEMS INCULT,UP100KT 61

UNIDATAUNI,6526B-21LCD 69

UNIMEASUREUNI,P75-3C 32

UNIVERSAL TECHNICUNI,P75-3C HYBRID-DP 32

USRADARUSR,SEEK-SPR 61

VAISALAVAI,WAA151 59

VAI,WXT520-KIT 68

VAN ESSENVAN,DI502 68

VARIACVAR,6500-3 36

VEEXVEE,TX-130+ 22

VEE,TX-130E+ 22

VEEX,TX-130M+ 22

VEHICLE COUNTSVEH,PC2500 56

VERMASONVER,222ES 8

VIVAXVIV,VCAM-120M 61

VIV,VCAM-60M 61

VIV,VLOCPRO 61

WEINSCHELWEI,33-10-34 19

WEI,34-30-34 19

WEI,WKL-100-40 50

WIKAWIK,GA-15 64

WOHLERWOH,VIS2000PRO 62

WOH,VIS340 62

WOH,VIS340-PT 62

WYLERWYL,CL45 54

WYL,PORTAPAINT 54

XANTREXXAN,XFR600-4 10

X-RITEXRI,SP60 69

YOKOGAWAYEW,51001-NATA 68

YEW,DR130 46

Manufacturers Index cont’d.

7

Page 10: normas quipment-solutions-guide

8

Electronics

Multimeters & Electrometers Digital Storage OscilloscopesProbes & AccessoriesFunction GeneratorsLCR MetersDC Power Supplies & LoadsSpectrum Analysers - Low FrequencyTV Test EquipmentElectronic CalibratorsGauss/Tesla MetersE & H Field Strength MetersEMC & Power Disturbance Simulators

See also Electrical Testers on page 24

Fluke 28II EX Intrinsically Safe True-RMS Multimeter

FLU,28II-EX AUIntrinsically Safe Multimeter is a completely sealed IP67 rated case. For use inside and outside of hazardous zones. Measures up to 1000V, 10A AC and DC with true-RMS for accurate measurement on nonlinear

signals. Frequency measurements to 200 kHz, resistance, conductance, diode test, capacitance, and temperature. Results are displayed on the bright, 4-1/2 digit LCD (20,000 counts).

Fluke 87-5 Industrial True-RMS Multimeter with ThermometerFLU,87-5 MYUnique function for accurate voltage and frequency measurements on adjusatable speed motor drives and other electrically noisy equipment.True-RMS AC voltage and current for accurate measurements on non linear signals. Built in thermometer. Measure up to 1,000VAC and DC.

Measure up to 10A (20A for 30 seconds). 10,000uF capacitance range. Frequency to 200kHz and % duty cycle. Peak capture to record transients as fast as 250μs. 4½ digit mode.

Fluke 289 True-RMS Logging Multimeter with FlukeView Software FLU,289 FLUKEVIEW (1209) AUComplete with a built-in data logger to record measurements unattended. Internal memory allows stand-alone logging for up to 180 hours. True-RMS 50,000-count ¼ VGA dot matrix display. 0.025% Basic DC accuracy. CAT III 1000 V/CAT IV 600 V safety rated. Supplied with FlukeView software and download cable.

See also Data Loggers on page 47-48

Agilent/HP 34401A Digital Multimeter HP,34401A (1200) AUPrecision 6½ digit multimeter. 100nV sensitivity on DC 120mV range. Max DC input 1kV. Measures AC voltage, DC & AC current to 3A, 2 or 4 wire

resistance to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions including limits test. 512 point storage. RS232 & HPIB interfaces.

Vermason 222541 Electrostatic MeterVER,222ES (1246) AUElectrostatic meter for periodic audits of facilities, monitoring packaging, materials, machines and other electrostatic generative equipment or processes. This precision field meter is designed to measure electrostatic voltage potentials over selected distances from 1 to 20cm. Range at the standard distance of 2cm is 20kV. Two range 3 digit display in V or kV.

Digital Storage OscilloscopesAgilent DSOX3024A Oscilloscope 200MHz 4 Channels

AGI,DSOX3024A (1350) AU4 channel 200MHz digital storage oscilloscope.

Sampling rate 2 G/s (4 G/s half-channel interleaved mode). 2Mpts memory depth, waveform update rate 1 million waveforms/s, sensitivity 1mV/div to 5V/div and 16 digital channels. Built-in 20 MHz function/arbitrary waveform generator. Pass/fail masks can be automatically created based on an input reference waveform or on a PC then imported via USB, also store and remove waveforms via USB.

Agilent MSOX3024A 200MHz Scope 4+16Ch with Logic AnalyserAGI,MSOX3024A (1340) AUMixed signal oscilloscope. 4 analogue and 16 digital channels 200MHz bandwidth, 4Gsa/s,

2Mpts memory, 1M/s waveform update rate. Search and navigate capability. Integrated time-aligned digital and analog signal viewing. USB storage, LAN operability.

Agilent MSO6104A 1GHz Digital Oscilloscope with LogicAGI,MSO6104A (1320) AU1GHz 4 + 16 channel mixed signal oscilloscope (MSO). 4Gsa/s. XGA Colour display updates 100,000 waveforms/s with 256 levels intensity.

4 analogue channels & 16 logic channels. Deep memory. 8 digit frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, & USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces standard.

Fluke 199C Scopemeter 200MHz Hand-heldFLU,199C-SCOPEMETER (1360) AU

200MHz bandwidth 2 channel colour digital oscilloscope with DMM feature. 14.4cm colour display with persistence feature. 2.5GS/s real time sampling. Input sensitivity 5mV/div to 100V/div. Glitch capture 3ns using pulse width triggering. Timebase range in scope mode 5ns/div to 2min/div. Trigger types auto, free run, single shot,

edge, delay, video, video line, selectable pulse width and external. Automatic capture and replay of last 100 screens. Measures electrical power properties such as VA VAR, etc. Isolated inputs.

Tektronix TDS3054B 500MHz 4 Channel DSO TEK,TDS3054 MYSampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10v/div. Time base 1ns to 10s/div. Trigger functions include video. Extensive automatic waveform measurements. Including FFT, TV trigger, advanced analysis (TDS3AAM), and limit testing (TDS3LIM). Battery operation.

Multimeters & ElectrometersTe

Multimeters & Electrometers cont’d.

www.techrentals.com.au

Page 11: normas quipment-solutions-guide

99

For all your Agilent rental equipment, contact TechRentals

Page 12: normas quipment-solutions-guide

10

Function Generators cont’d.Agilent/HP 33250A 80MHz Function/Arbitrary Waveform Generator HP,33250A (1618) AUFrequency range 80MHz sine & square waveforms. 50MHz pulse

waveforms with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle & ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp to 10Vpp. AM, FM, FSK, & burst modulation. Intuilink software for programming arbitrary waveforms. HPIB & RS232C interfaces.

LCR MetersHioki 3532-50 5MHz LCR MeterHIO,LCR 3532-50 (1290) AUFrequency range 42Hz to 5MHz. 5ms high speed measurements. Basic accuracy of ±0.08%. Memory for 30 sets of measurement conditions, including comparator values.

Includes correlation correction function, interactive touch panel operation and enlarged display function. Applications include laboratory use for evaluation of operating characteristics, production line use or R&D. Measurement data captured by a personal computer can be displayed graphically by using standard spreadsheet software.

DC Power Supplies & LoadsAgilent/HP 6675A DC Power Supply HP,6675A MY102VDC, 18A, 2000W, auto-parallel up to five units, output can be connected in series, programmable over-voltage and over-current protection, over-temperature protection, Discrete Fault Indicator/Remote Inhibit (DFI/RI), self-test occurs at power-on from an GPIB command, user definable power-on state and VXI plug & play drives.

Sorensen DCS 150V, 20A DC Power Supply SOR,DCS150-20E (8130) AU0-150V, 20A, 3KW. Applications

range from manufacturing test and burn-in of automotive components, avionics electronics, telecommunications and consumer products to beam steering, process control, laboratory R&D use. Remote control via LAN or RS232.

Sorensen DCS60-50 60V 50A DC Power Supply SOR,DCS60-50 (8140) AU0 to 60V, 0 to 50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph 240V supply. On 1ph 50V@50A or 60V@42A. Remote programming.

TR Built 12V Battery Supply with Cigarette Power Connector TR,12V-BAT-CIG (8160) AU12V 20AH battery pack with built-in charger. Has cigarette outlet and banana plug connectors.

Trio Kenwood PD35-20 DC Power Supply TRI,PD35-20 (8150) AUOutput 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple parallel or series operation. Remote programming of voltage or current by external voltage or resistance.

Xantrex XFR 600-4 600V 4A Power Supply XAN,XFR600-4 (8120) AU

2.4kW programmable DC power supply 0~600V, 0~4A with remote analog programming.

Digital Storage Oscilloscopes cont’d.Tektronix THS730A 200MHz Battery DSO TEK,THS730A MYDual channel battery portable 200MHz digital storage oscilloscope with digital multimeter facilities. Maximum sampling rate 1GS/s. Maximum input 640V rms, maximum float 600V rms. Waveform processing including watts calculations. Video trigger. RS232 interface.

Tektronix TPS2014 100MHz 4 Channel PowerscopeTEK,TPS2014 (1370) AUSampling rate 1GS/s. All 4 channels isolated for floating measurements. Sensitivity 2mV to 5V/div. Measurements

for current and voltage distortion and their spectral content, harmonics, instantaneous power, power factor and switching loss. Automatic waveform measurements. FFT, power analysis, low & high voltage power probes (P5120). Battery operation.

Probes and AccessoriesChauvin Arnoux Current Probe E3N 0 to 100 AmpCHA,PROBE-I (1440) AUCurrent probe for oscilloscopes which uses a Hall effect cell for the measurement of DC or AC current. Measures currents from 50mA to 100A peak. A thumbwheel can be used to reset zero for adaption to the measurement environment. The clamp can be used with any measurement instrument which has a BNC input and an impedance of 1MΩ, <100pF.

Fluke 80K-40 High Voltage ProbeFLU,80K-40 (1219) AU1 to 40kVDC or peak AC, 28kVAC RMS. Input resistance 1GΩ, division ratio 1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be wrong.

Tektronix P6015 40kV High Voltage Probe TEK,P6015 (1450) AUBandwidth 75MHz. Input rating: 40kV pulse, 20kVDC plus peak AC. Derating with frequency applies. Input impedance 100MΩ. Attenuation x 1000.

Function Generators See also RF Signal & Sweep Generators on page 14

Agilent/HP 33120A 15MHz Function/Arbitrary GeneratorHP,33120A MYFunction/Arbitrary Waveform Generator. Frequency 15MHz sine and square waveforms, and 100kHz triangle and ramp waveforms. Gaussian noise to 10MHz. Output into 50ohms 50mV to 10VP-P. AM, FM, FSK and bust modulation. HP-IB and RS-232C interfaces both standard.

Agilent/HP 33220A 20MHz Function/Arbitrary GeneratorHP,33220A (1613) AUFrequency range 20MHz sine & square waveforms, 200kHz pulse, triangle, ramp,

noise, & DC waveforms. Gaussian noise to 10MHz. Output into 50Ω 10mV to10V P-P. AM, FM, FSK, & burst modulation. Includes option 001 external timebase reference. With optional Benchlink software waveforms can be captured & played back. HPIB, USB, & LAN interfaces.

10

Electronics www.techrentals.com.au

Page 13: normas quipment-solutions-guide

11

Spectrum Analysers - Low Frequency See also Spectrum Analyser - High Frequency on page 14-16 See also Noise & Sound Analysers on page 65

Agilent/HP 35670A 100kHz Spectrum Analyser HP,35670A (2480) AUQuad channel 122μHz to 102.4kHz spectrum analyser. Up to 1600 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power

spectral density, and time. Signal sources: Fixed & swept sine, arbitrary waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface. Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel measurements respectively.

TV Test Equipment See also Network Analysers/Antenna & Cable Test on page 16

Promax HD Ranger DVB-T-S-C TV Analyser

PRO,HD RANGER (1726) AUTV analyser that covers DVB-T/C/S/S2 with MPEG-2 as well as MPEG-4 video with an ultra fast spectrum analyser. Applications include TV installation, maintenance and

surveillance. 18 cm bright display for use in direct sun light. Constellation diagram available for DVB-T/C/S/S2. Datalogging with the aid of an on-screen wizard.

Promax TV Explorer Prodig-5 PRO,PRODIG-5 (1727) AUFor the installation, maintenance and surveillance of terrestrial, satellite and cable TV systems. Automatically provides information about the channels available in the network and their quality. Displays analogue and digital channel picture. Includes a high resolution spectrum analyser function and MPEG decoding. Foxtel approved.

Electronic Calibrators See also Industrial Process Calibrators on page 42-45

Fluke 5500A Multi Product Calibrator with NATA Calibration FLU,5500A-NATA (1660) AUFLU,5500A MYCalibrator sources direct voltage & current, alternating voltage and

current, with multiple waveforms and harmonics, 2 simultaneous voltage outputs or voltage & current. Simulates power with phase control, resistance, capacitance, thermocouples and RTDs. Selectable ranges include the following outputs VDC from 0 to 1.02kV, VAC from 1mV to 1.02kV with output from 10Hz to 500kHz. AC current from 0.01μA to 11A with output from 10Hz to 10kHz. DC current from 0 to 11A. Resistance values from short circuit to 330MΩ. Capacitance values from 330pF to 1,100μF. Temperature t/c B, C, E, J, K, L, N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω, Pt385 200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.

Genrad 1433B 1.1MΩ 6 Decade Resistance GR,1433B-NATA (1670) AUSix decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated.

Electronic Calibrators cont’d.Genrad 1433F 111KΩ 7 Decade Resistance BoxGR,1433F-NATA (1680) AUSeven decades by 0.01Ω to 111k. Accuracy 0.01% +0.002Ω. Useful for platinum resistance thermometer calibration. NATA calibrated.

Genrad 1433-20 11.1111kΩ 6 Decade ResistorGR,1433-20 MYSix decades by 0.01Ω per step to

11.1111kΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature coefficient, 5ppm/˚C. Good frequency characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade). May be used for RTD stimulation. Rack mount option.

Gauss/Tesla MetersFW Bell Gauss/Tesla MeterBEL,4190 (1969) AUHandheld digital ELF gauss meter. Maintains accuracy regardless of orientation. Applications include detecting magnetic field emissions from overhead AC power lines, video display terminals, office equipment and household appliances. Analogue o/p, data logging, auto range 0.1 to 1999 mG, minimum resolution 0.1mG/.01 uT.

FW Bell 5180 Gauss/Tesla MeterBEL,5180 (1960) AUMagnetic measuring equipment, portable gaussmeter. Functions include Auto Zero, Min/Max/Peak Hold, Auto Range and Relative Mode. Displays in Gauss, Tesla or Ampere/Meter. With Hall effect transverse probe. Bandwidth DC to 30kHz, ranges 300G to 30kG, resolution 0.1G. Analogue output (±3V FS) and USB interface. Battery operated.

E & H Field Strength Meters See also Radiation Montioring & Protection on page 66

Holaday HI-3604 E & H Survey Meter ELFHOL,HI-3604 (1945) AULow frequency field meter. Designed to evaluate electric and magnetic fields associated with 50Hz power lines. Frequency range 30 to 2,000Hz. Measures magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from 1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory.

Holaday HI-3627 Magnetic Field MeterHOL,HI-3627 (1980) AUThree orthogonal field sensors. Dynamicrange 0.2mG to 20G. True RMS detection. Frequency range 5Hz to 2kHz with an in-built 30Hz high pass filter. Meets requirements of the Swedish protocol and the IEEE P-1140 protocol.

www.techrentals.com.au Electronics

Page 14: normas quipment-solutions-guide

12

EMC & Power Disturbance SimulatorsLaplace SA1000 EMC Test System LAP,SA1000 (8370) AUComprises PC controlled spectrum analyser 10kHz to 1.1GHz, SA1020 pre-amplifier, RF200 broadband antenna 30MHz to 1GHz, TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied with notebook PC and EMC software. EMC compliance test system.

Schaffner 438 30kV Static Discharge Generator SFN,438 (8375) AUGenerates an electrostatic charge in a range from 2 to 30kV. This instrument is in a ‘gun’ form. Has a removable discharge network which can be interchanged with other (optional) impedance networks. Performs test to IEC61000-4-2 (AKA, IEC 1000-4-2) standards.

Schaffner Modula-6100 Immunity Test System SFN,MODULA 6100 (8380) AUMultifunction generator to simulate electro-magnetic field interference effects for immunity testing in conformity with

international, national and in house standards including the new IEC/EN standards. Generates Interference pulses such as burst and surge and power quality simulations.

E & H Field Strength Meters cont’d.Narda NBM-520 ‘E’ Field Strength Meter and Probe EF1891

NAR,NBM-520 (1925) AUField strength meter with EF1891 ‘E’ field probe. Detects electric fields from 3 MHz to 18 GHz, covering fields generated by broadcasting, telecoms, radar and any other transmission sources within this range. Dynamic range from 0.6V/m to 1,000V/m. Applications include measuring field strengths to comply with general safety regulations and actual radiated power. Includes fibre optic cable with optical to electrical converts for remote monitoring.

Narda NBM-550 ‘E’ Field Strength Meter and Probe EF1891NAR,NBM-550 (1930) AUField strength meter with EF1891 ‘E’ field probe. Detects electric fields from 3 MHz to 18GHz, covering fields generated by broadcasting, telecoms, radar and any other transmission sources within this range. Dynamic range from 0.6V/m to 1,000V/m. Includes GPS, data logging, voice recording annotation and fibre optic cable with optical to electrical converts for remote monitoring.

Electronics www.techrentals.com.au

TRAINING FROM TECHRENTALS

TechRentals, with the support of many manufacturers including Anritsu, Fluke, Agilent, Megger and Omicron, are able to provide tailored training suited for the electrical, networking, instrumentation and construction industries.

These partnerships allow TechRentals to work together to offer many types of training from online modules, to partner standard training. Your training requirements can be fully customised, whether it be high-end electrical, telecommunications, fibre optics or NDT testing.

When you rent you have access to:• Specific asset training as part of the set up and download service• Online training videos via our website to assist in operation of certain equipment

Periodically, TechRentals offer a number of short courses designed to enhance skills and experience in areas of particular benefit to technical personnel. Notices of these courses are sent by email requesting an expression of interest and take place throughout Australia. If you would like to receive these notifications please email [email protected].

The TechRentals Wiki is well worth a visit, as this resource centre provides manuals, technical information and how-to videos. Visit www.techrentals.com.au and select Technical Tips and Videos.

Don’t forget to visit the TechRentals YouTube site with over 100 videos containing training, practical demonstrations and much more. (http://www.youtube.com/techrentals)

Page 15: normas quipment-solutions-guide

13

Specialists in supplying IT hardware, project management, audio visual turn key solutions and facilitating short and long term projects on everything IT and AV, TR Vidcom delivers unparalleled levels of service and a comprehensive range of leading-edge products at competitive rates.

Our product range includes:

Our vision at TR Vidcom is to respond to clients’ needs by combining technology, equipment and technical expertise.

Get access to our large inventory of leading brands including HP, Apple, Lenovo, Dell, Samsung, Toshiba, Orion, LG and more...

Take advantage of our customised solutions and rental periods, and the fl exibility to update at any time. Our top technical advice and support is only one phone call away!

VC0294

1800 843 266 www.trvidcom.com.au

[email protected]

vidcom

Originally established in 1983 as the Computer Division of TechRentals, TR Vidcom is Australia’s most vibrant company in the exciting IT and Audio Visual industry.

• Notebooks and Desktops• LCD and Plasma Screens• Printers and Plotters• Multi Panel Plasma Displays• Projectors and Screens

• Apple Products• Servers and Networking• Video and Teleconferencing• Stocktake Equipment• Rich Media Streaming

Page 16: normas quipment-solutions-guide

14

RF Signal & Sweep GeneratorsFrequency CountersSpectrum Analysers - High FrequencyNetwork Analysers/Antenna & Cable TestCommunication Test SetsDistortion AnalysersPower Meters - RFRF Amplifi ersRF AttenuatorsAntennasRF Accessories

See also Function Generators on page 10

Agilent/HP 8648D-1E5 4GHz Signal Generator HP,8648D (2330) AUHP,8648D-1E5 MYSignal generator 9kHz to 4GHz with AM/FM/Phase modulation output range from

+10 to -136dBm with ±1dB accuracy up to 2.5GHz. 0.001Hz resolution. Complete with option 1E5 high stability timebase (<±0.1ppm/yr).

Agilent/HP E4433B ESG-D4000A 4GHz RF Digital Signal Generator HP,ESG-D4000A (2335) AUSignal generator with digital modulation facilities. Frequency range 250kHz to 4GHz, resolution 0.01Hz. AM, FM,

phase, and pulse modulation. Wideband AM modulation. Internal modulation and pulse generator to 50kHz. Step sweep of frequency and power. Option 1E5 high stability reference 0.1 ppm/yr included.

Frequency Counters See also Electronics on page 8

Agilent/HP 53181A 3GHz Frequency Counter HP,53181A (3112) AU/MYOption 010 high stability timebase included. HPIB interface. PC based Benchlink meter software available.

Agilent/HP 5350B 20GHz Frequency Counter HP,5350B MYMicrowave frequency counter. 10Hz to 20GHz. HPIB interface.

Spectrum Analysers - High FrequencyAdvantest 31.8GHz Portable Spectrum Analyser ADV,U3771 (2540) AU/MYPortable 9kHz to 31.8GHz spectrum analyser. 3 way power. Battery, 240V & DC. RBW 100Hz to 3MHz, sensitivity

-117dBm@34GHz (typ). High-stability reference. Includes a wide variety of data analysis functions & zoom function. With signals applied to both Input 1 and Input 2, two signals such as an IF signal and a carrier can be measured. Support for USB for printer and memory. Storage image formats: PNG, BMP, configuration file BIN, XML.

Agilent N9340A 3GHz Spectrum Analyser with Tracking GeneratorAGI,N9340A (2565) AU

Portable handheld spectrum analyser with a frequency range from 100kHz to 3GHz. Resolution bandwidth 30Hz to 1MHz. Includes tracking generator. DANL -126dBm (typical). Sweep time 10ms. USB connectivity allows for PC control and data transfer.

Agilent N9344C 20GHz Spectrum Analyser with Tracking Generator

AGI,N9344C (2538) AUAGI,N9344C-TG MYSpectrum analyser 9kHz to 20GHz with

5MHz to 7GHz tracking generator. -144dBm displayed average noise level (DANL), <0.95s sweep time for 20GHz full span. Average continuous power, +30dBm for 3 minutes maximum. Flexible remote control via USB/LAN. User memory 64MB, able to store approximately 14,000 traces.

Airmagnet Wi-Fi Spectrum AnalyserAIR,AIRMAG SPEC AN (2580) AULaptop based spectrum analyser. Specifically identify sources of interference in Wi-Fi bands 2.4-2.5GHz (802.11 b/g) and 4.9-5.9GHz (802.11a), and track them to their physical source. Automatic and real time identification of Bluetooth, cordless phones, microwaves, analogue video cameras, RF jammers and more. Immediately “see” and name each device.

Anritsu MS2711A 3GHz Portable Spectrum Analyser ANR,MS2711A MYPortable spectrum analyser, 9kHz to 3GHz. Light weight battery powered spectrum analyser with LCD. Resolution bandwidth down to 10kHz. Suitable for cellular telephone

walk or drive tests to determine coverage and base station positioning. Can also be used for VHF/UHF signal surveying. N type connector.

Anritsu MS2712E 4GHz Spectrum Analyser/Tracking Generator

ANR,MS2712E (2560) AUPortable handheld spectrum analyser 9kHz to 4GHz, DANL -162dBm in 1Hz RBW, RBW 1Hz to 3MHz. Tracking generator -50dBm to

0dBm in 0.1dB steps. Applications include, spectrum monitoring, broadcast proofing, RF and microwave measurements, Wi-Fi and wireless network measurements. Store up 2,000 traces and setups on board or on USB flash drive. One-button envelope creation, Trace Save-on-Event feature.

RF Signal & Sweep Generators

Radio Frequency www.techrentals.com.au

Stay informed on T&M news, application notes and case studies with @TechRentals on Twitter

Page 17: normas quipment-solutions-guide
Page 18: normas quipment-solutions-guide

16

Spectrum Analysers - High Frequency cont’d.

Anritsu MS2721A 7.1 GHz Spectrum Analyser ANR,MS2721A (2550) AU100kHz to 7.1GHz. For deploying, maintaining and troubleshooting wireless base stations and Wi-Fi (802.11a, b and g) systems, and general spectrum analysis. Smart

measurements include channel power, adjacent channel power ratio, carrier to interference ratio and field strength. AM/FM/SSB demodulator included and internal speaker for monitoring. DANL -153 dBm at 1GHz. Phase noise -100dBc/Hz at 10KHz. Store unlimited traces and setups. Remote programming via Ethernet port.

Rohde & Schwarz FSH3 3GHz Spectrum Analyser/Tracking Generator/Vector MeasurementR S,FSH3-TG-V (2575) AURS,FSH3-TG MYHandheld portable battery operated spectrum analyser 100kHz to 3GHz. Resolution bandwidth 1kHz to 1MHz. Less than -105dBm noise level (-114dBm typical). Suitable for RF surveying applications. Includes vector transmission and tracking generator options.

Network Analysers/Antenna & Cable Test

Anritsu S331D 4GHz Colour Sitemaster Antenna ANR,S331D (2185) AU/MY

Antenna and cable test set. Frequency range 25MHz to 4GHz. Measures return loss, SWR, cable loss, and distance to fault. Return loss range 0 to 60dB. SWR range 1 to 65. Distance

to fault range 1,197m. Insertion loss range -120 to +100dB. Cable loss range (one port) 0 to 30dB. N(f) Type port. Analysis software discs included containing distance to fault and Smith chart tools. Complete with calibration standard, AC/DC adaptor, and 12VDC car cigarette lighter adaptor.

Anritsu S331E 4GHz Sitemaster Cable & Antenna Tester

ANR,S331E (2180) AU/MYCable and antenna analyser, frequency range 2MHz to 4GHz. Measures return loss, VSWR, cable loss, and Distance To Fault. Suitable for

legacy networks in addition to the new 3G and 4G networks being installed. Applications include cable & antenna installation and maintenance for wireless service providers, contractors, military, aerospace, defence, and public safety applications.

Anritsu S332D Colour Sitemaster Antenna Tester ANR,S332D MYAntenna and cable test set including spectrum analyser. Frequency range 25 to 4,000MHz. RBW 100Hz to 1MHz. Measures return loss, SWR, cable loss, and distance to

fault. N(f) Type port. Analysis software containing DTF and Smith chart tools included. Complete with calibration standard, AC/DC adaptor, and 12VDC car adaptor.

Network Analysers/Antenna & Cable Test cont’d.

Anritsu S332E Sitemaster including Spectrum Analyser ANR,S332E (2175) AUAntenna and cable analyser 2MHz to 4GHz and spectrum analyser 100KHz to 4GHz. DANL -152dBm. Measures return loss, VSWR, cable loss, and distance to fault. N(f) Type port. Analysis software containing

DTF and Smith chart tools included. Complete with calibration standard, AC/DC adaptor, and 12VDC car adaptor. Cable & antenna installation and maintenance for wireless service providers, contractors, military, aerospace and defence, and public safety applications.

Anritsu S332E Sitemaster Including Spectrum Analyser and Opt 431,31,509 ANR,S332E-CMPA-MOD (2165) AUantenna and cable analyser 2MHz to 4GHz and spectrum analyser 100KHz to 4GHz. DANL -152dBm. Options included, indoor outdoor Coverage Mapping, GPS Receiver and AM/FM/PM Analyser. Measures return

loss, VSWR, cable loss, and distance to fault. Analysis software containing DTF and Smith chart tools included. Cable, antenna, installation and maintenance spectrum analysis, coverage mapping and AM/FM/PM demod for wireless service providers, contractors, military, aerospace and defence, and public safety applications.

Anritsu S820D Microwave Sitemaster 25MHz to 20GHz ANR,S820D (2150) AU/MYMicrowave antenna and cable test set. Portable single port analyser, providing return loss (SWR) insertion loss and distance to fault measurements in the frequency

range of 25MHz to 20GHz. Unit comes standard with RS232 interface, Smith chart and software management tools, AC/DC and automotive adaptor. A comprehensive range of precision waveguide components and adaptors are available.

Anritsu Sitemaster Waveguide Components ANR,WAVEGUIDE-ADAP (2190) AU/MYCalibration components and wave guide to co-ax adaptors for Anritsu S820x Sitemaster. Set includes 1/8 and 3/8 shorts, termination, and waveguide to co-ax adaptor.

Agilent/HP 8753D 6 GHz Vector Network Analyser HP,8753D (2745) AUTwo port vector network analyser with integral S-parameter test set. Frequency range 30 kHz to 6 GHz with included option 006. In-built 1Hz resolution synthesized signal source. Calibration kit included.

Communication Test Sets Aeroflex IFR 2945B Communications Service Monitor IFR,2945B (2368) AUCommunications Service Monitor is ideally suited to the testing of two way radios and

trunking repeaters allowing verification of performance, and rapid diagnosis of faults. Includes a combination of test instruments such as a full performance spectrum analyser, oscilloscope and tracking generator. Frequency range 400kHz to 1.05GHz.

Radio Frequency www.techrentals.com.au

Page 19: normas quipment-solutions-guide

17

BR02

56

Get your FREE Sepura TETRA two way radio demo!

To book your free demonstration, call our friendly team today on 1800 222 327, or email us at [email protected]

Melbourne | Sydney | Newcastle | Brisbane | Townsville | Adelaide | Darwin | Perth

TR Hirecom is offering FREE demonstrations of the Sepura range of TETRA radios from our diverse fl eet.

Your free demo will include:

Comprehensive Site Test

Demonstration of TETRA Repeaters

and TETRA Radios

Educational TETRA White Paper

A clear understanding of what a TETRA System

can achieve for your organisation

Sepura STP9000 TETRA Digital Hand Held Portable Two Way Radio• Large colour screen

• 1.8 W RF power

• Full keypad

• Dustproof, waterproof

and submersible IP67 rating

• Integrated Bluetooth option

• GPS capability

• Robust and secure

• Integrated RFID tag

Sepura STP9200 TETRA Digital Hand Held Portable Two Way Radio• 1.8 W RF power

• Monochrome screen

• Enhanced and intuitive user interface

• Dustproof, waterproof and submersible

IP67 rating

• Integrated RFID tag

• GPS capability

Sepura STP9100 TETRA Digital Hand Portable Two Way Radio• 1.8 W RF power

• Large colour screen

• Dustproof, waterproof and submersible

IP67 rating

• Integrated Bluetooth option

• GPS capability

• Robust and secure

• Integrated RFID tag

Sepura STP8X IS TETRA Digital Hand Held Portable Two Way Radio• Full, tactile keypad

• IP67 Rating

• V6 IECEx/ATEX approval

• Loud and clear audio

• Man down alarm

• GPS option

• Bluetooth connectivity

• Intrinsically Safe

• MicroSD card slot

hirecom

Call to arrange your FREE demo 1800 222 327

Page 20: normas quipment-solutions-guide

18

Power Meters - RF cont’d.Marconi 6970 Digital Power Meter MAR,6970 MYNiCd battery operated with digital display. Complete with AC adaptor. Requires sensor. Sensors available for 10MHz to 26.5GHz frequency range.

Marconi 6910 Power Sensor MAR,6910 MYFrequency range 10MHz to 20GHz. Power range -30dBm to 20dBm (1μW to 100mW). Max RF i/p 25dBm (300mW) CW 42dBm (15W) peak for 2μs. Sensing element semiconductor thermocouple. VSWR 1.25: 10MHz to 30MHz, 1.1: 30MHz to 2GHz, 1.18: 2 to 16GHz, 1.28: 16 to 18GHz, 1.4: typical 18 to 20GHz. Linearity factor provided with sensor. Accuracy ±0.5% at 25˚C between 10 & 20dBm. Improves by a factor of 10 for each lower range. Calibration factor provided with sensor. Accuracy uncertainty provided with sensor. Resolution 0.01%. RF connector precision N-type (M) 50Ω.

Marconi 6912 Power Sensor MAR,6912 MYFrequency range 30kHz to 4.2GHz. Power range 30dBm (1μW) to 20dBm (100mW).

Marconi 6913 Power Sensor MAR,6913 MYFrequency range 10MHz to 26.5GHz. Power range 30dBm (1μW) to 20dBm (100mW). Max 25dBm (300mW) CW, 42dBm (15W) peak for 2μs. Sensing element semiconductor thermocouple. VSWR 1.40: 10MHz to 50MHz, 1.15: 50MHz to 100MHz, 1.10: 100MHz to 2GHz, 1.15: 2 to 12.4GHz, 1.20: 12.4 to 18GHz, 1.25: 18 to 26.5GHz. Calibration factor provided at 1GHz intervals (500MHz intervals above 20GHz) with each sensor. Accuracy uncertainty provided with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5% at 100mW, decreasing by 0.005% per 1mW.

Marconi 6920 Power Sensor MAR,6920 MYHigh sensitivity diode sensor. Frequency range 10MHz to 20GHz. Power range -70dBm (0.1nW) to -20dBm (10μW), max 26dBm (400mW) CW +30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR 1.4 to 1.2:10 to 40MHz, 1.20:40MHz to 10GHz, 1.35:10 to 18GHz, 1.40 typical 18 to 20GHz. Calibration factor provided at 1GHz intervals with each sensor. Accuracy uncertainty provided with each sensor.

Marconi 6923 RF Power Sensor MAR,6923 MYHigh sensitivity diode sensor. Frequency range 10MHz to 26.5GHz. Power range -65dBm (0.3nW) to -20dBm(10μW), max 26dBm (400mW) CW, +30dBm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR 1.4 10 to 40MHz, 1.15 40 to 100MHz, 1.12 0.1MHz, 1.17 2 to 8GHz, 1.30 8 to 18GHz, 1.50 typical 18 to 26.5GHz. Calibration factor provided at 1GHz intervals with each sensor. Accuracy uncertainty provided with each sensor. Resolution 0.01%. Linearity factor provided with each sensor. Accuracy ±1% between -30 to -20dBm. RF connector type N (M) precision 50Ω.

Rohde & Schwarz NRT Power Reflection Meter RS,NRT (2140) AUMeasures directional power forward and reverse under operational conditions. NRT-Z44 sensor included, range 3 mW to 120 W, 200 MHz to 4 GHz. Measurement method is compatible with all common analog and in particular digital modulation standards. GSM/EDGE, 3GPP (W-/TD-CDMA), CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T and many more.

Communication Test Sets cont’d.Aeroflex IFR 3500A Radio Communications Test Set IFR,3500A (2360) AUCommunications service monitor. Portable radio test set for AM, FM, P25, DMR and NXDN radio transceivers, antenna and cable testing in vehicle, at remote locations or on bench testing. Frequency range 2M to 1GHz. 20W power handling without external attenuator. Includes spectrum analyser, oscilloscope, tracking generator and 75W 6dB attenuator.

Distortion AnalysersAgilent/HP 8903B Audio Analyser HP,8903B (3020) AUAudio analyser for communications and other applications. Measures distortion, sinad, signal-to-noise, ACV, DCV, frequency. Low distortion programmable sine wave source. Frequency range 20Hz to 100kHz. Optional 400Hz high pass and CCITT weighting filters fitted.

Power Meters - RFAgilent/HP E4418B E Series Power MeterHP,E4418B-001 (2120) AU100μW to 25W (-70dBm to 44dBm), 9 kHz to 110 GHz (power sensor dependent ), 4 digit display - watts, dBm, dB (rel). Battery or mains powered. Power sensor required, select and specify when ordering.

Agilent/HP E9300A Power Sensor 1μW to 100mW, 10MHz to 18GHzHP,E9300A (2125) AUPower sensor for HP EPM series power meters. E-series average power sensor. 10MHz to 8GHz, 1μW to 100mW (-60dBm to 20dBm).

Agilent/HP E9300B Power Sensor 1μW to 25W, 10MHz to 8GHz HP,E9300B (2135) AUPower sensor for HP EPM series power meters. E-series average power sensor. 10MHz to 18GHz, 1μW to 25W (-30dBm to 44dBm).

Anritsu MA24104A Inline Power Sensor 0.6 to 4GHz, 2mW to 150WANR,MA24104A (2115) AUA dual path architecture that enables true RMS measurements over the entire frequency and dynamic range allowing users to measure CW, multi-tone and digitally modulated signals such as GSM/EDGE, CDMA/EV-DO,WCDMA/HSDPA, WiMAX, and TD-SCDMA. Can be connected directly to a laptop or Site Master with option 19.

Bird 43 Power MeterBIR,43 MYRF thruline power meter. Requires Bird element of specified frequency and power. Measures forward and reflected power by reversing the element.

Bird RF ElementBIR,ELEMENT-LF MYBIR,ELEMENT-HF MYRF elements for Bird watt meters. Available in various power and frequency ranges.

Radio Frequency www.techrentals.com.au

Page 21: normas quipment-solutions-guide

19

RF Amplifi ers ENI 604L 4W Wideband 1GHz RF AmplifierENI,604L (2803) AULinear wideband RF power amplifier. 4W output at an input of 0.13mW from 0.5 to 1GHz. Saturated output 7W 0dBm input. Extended performance gives saturated output to a max of 16W at 10MHz and 12W at 100MHz typically.

Agilent/HP HP8449B Preamplifier 1GHz to 26.5GHzHP,8449B MYHigh-gain (+30dB gain), low-noise preamplifier. Frequency range of 1 to 26.5GHz. Increases sensitivity of any microwave spectrum analyser for detection and analysis of very low-level signals. Improved sensitivity can reduce measurement time.

RF AttenuatorsAgilent/HP 8494B/8495B Attenuator Set 81dB, 1 & 10dB steps 18GHzHP,8494B-8495B (2904) AU/MYCoaxial step attenuator set. DC to 18GHz. 0-11dB in 1dB steps and 10-70dB in 10dB steps. Type N(f) connectors. Comprises a connected set of types 8494B and 8495B with 11716A rigid interconnect kit.

Agilent/HP 8495B 70dB x 10dB Coaxial Step Attenuator HP,8495B (2902) AUDC to 18GHz. 0 to 70dB in 10dB steps.

Agilent/HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB HP,8494/5B MYDC to 18GHz. 0 to 11dB in 1dB steps. 11 to 81dB in 10dB steps. Comprises a connected set of types 8494B & 8495B. Type N(f) connectors.

Agilent/HP 8495D 70dB 26.5GHz Step Attenuator HP,8495D (2905) MYFrequency range DC to 26.5GHz. 70dB step attenuator in 10dB steps. Max continuous power 1W. 3.5mm connectors.

Anritsu Attenuator 50W 30dB DC to 18GHzANR,50-30-18 (2903) AU30dB, 18GHz, 50W. N Type connectors.

Weinschell 33-10-34 25W 10dB 8.5GHz RF Attenuator WEI,33-10-34 (2919) AUDC to 8GHz, 10dB, 25W. Type N connectors.

Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator WEI,34-30-34 (2922) AUDC to 4GHz, 30dB, 25W. Type N connectors.

AntennasAdvantest TR1720 100kHz to 30MHz Antenna ADV,TR1720 (1847) AULoop and vertical antenna system. Frequency range 100kHz to 30MHz. Suitable for use with ADV,R4131D for field strength and EMI measurements. An antenna tuner is included which can be used as an input/output filter to reject noise below the measuring frequency.

AH Systems 300MHz to 12GHz Antenna System AH,ANTENNA (1834) AULog periodic antenna system. Comprises two antennas: A: 300MHz to 1.8GHz, power handling 1kW, antenna factor 15 - 32dB, B: 1 to 12GHz, power handling 10 W, antenna factor 25 - 44dB. Complete with tripod.

Antennas cont’d.AH Systems SAS-200/550-2B 100Hz to 60Mhz Rod Antenna AH,SAS-200/550 (1837) AUMonopole rod antenna. Frequency range 100Hz to 60MHz. Active unit with battery power. Rod height 220mm to 1.09m. Ground plane 450 x 450mm. Antenna factor 0 to 24.

AH Systems SAS-200/571 Antenna AH,SAS-200/571 (1840) AUAH,SAS-571 MYDouble ridge guide horn antenna. Frequency range 700MHz to 18GHz. Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type N(f) connector.

Anritsu Dipole Antenna Kit ANR,ANTENNA (1834) AUMP534A dipole antenna 25 to 520MHz and MP651A 470 to 1700MHz.

Directional Yagi AntennaANT,DIRECTIONAL YAGI (1829) AUVarious directional Yagi antennas. Frequency rangers from 824 M (UHF) to 2.17 GHz (UHF).

Omnidirectional AntennaANT,OMNIDIRECTIONAL (1826) AUVarious omnidirectional antenna types such as telescopic whip, folded dipole and monopole. Frequency ranges from 70MHz to 2.17GHz.

COM Power Double Ridged Horn Antenna 1 to 18GHzCOM,AH-118 MYFrequency range 1 to 18GHz, VSWR 2.0:1, Polarization: Linear, Output Impedance: 50Ω, connector types Antenna output: N (f).

RF Accessories RF Connector Kit N, BNC, TNC, SMA, APC7 TR,RF-CONN (2816) AURF connection adaptors. Comprises couplers with interchangeable connectors; DIN 7/16, N Type, BNC, SMA, TNC, APC-7 and UHF

Huber & Suhner Sucoflex 104PE 26.5GHz RF Cable SUH,SUCOFLEX-104PE MYFexible high performance microwave cable with frequency range up to 26.5GHz. Length 1.0 meter and comes with 3.5mm connectors.

www.techrentals.com.au Radio Frequency

Our rental with purchase option scheme is available to approved business customers.Generally the rates quoted on the rental purchase option are based on a 12 month rental periodafter which you may purchase the equipment by paying an amount equal to month’s rental.

However these plans can be tailored to suit your particular timeframe requirements.

If you have any questions about this scheme or the type of equipment that would apply please call our technical representatives to discuss your requirements.

Page 22: normas quipment-solutions-guide

20

LAN Cable TestersLAN/WAN AnalysersPDH/SDH AnalysersDSL/POTS Test SetLight Sources & Power MetersFusion SplicersOTDR & Fibre InspectionFibre Optic Launch Cables & Patch Leads

Fluke DSX-5000 Cable Analyser 1 GHz Class FAFLU,DSX-5000 (3278) AU

1GHz cable analyser copper test solution enables testing and certification of twisted pair cabling for up to 10 GigE deployments and will certify shielded and

unshielded structured cabling systems Cat 3, 4, 5, 5e, 6, 6A, Class C, D, E, EA, F, and FA at Level V accuracy. 9 second Cat 6 autotest. Built in Alien Crosstalk testing capability. LinkWare PC reporting software included.

Fluke DTX1800 Cable Analyser900MHz Cat 7FLU,DTX1800 (3260) AU/MY

Category 7 cable certification tester up to 900MHz. Tests to Category 3, 4, 5, 5E, 6, 6a and 7. Cable analyser for use with shielded and unshielded twisted pair Cat 6Autotest time of 12 seconds. Linkware PC software, and USB cable included. Internal memory stores results. Optional multimode & single mode OTDR module.

Fluke DTX-MFM2 Multimode Fibre Adaptor for DTX Cable AnalyserFLU,DTX-MFM2 (3270) AU/MY

DTX1200/1800 multimode fibre interface. Tests fibre installations in local area networks. Fits in the slot on the back of DTX cable analyser (standard

copper cable adaptors can be connected but not used simultaneously). Provides fibre testing and certification. Bi-directional testing at 850nm & 1300nm at the same time. Measures optical power loss, length, and propagation delay for multimode fibres. Pass/fail results based on common fibre standards. Includes in built visual fault locator. (VFL).

Fluke DTX Compact OTDR SM-MMFLU,DTX-OTDR (3280) AUFull featured multimode & single mode OTDR module

that snaps onto a DTX Cable Analyser. Shoots and analyses traces on single mode 9nm and multimode 62.5 & 50nm fibre.

Fluke DTX Permanent Link Adaptor AnalyserFLU,DTX-PLA (3295) AUFluke PLA001 Permanent Link Adaptor.

Fluke DTX Fibre for DTX Cable AnalyserFLU,DTX-SFM MYDTX1200/1800 singlemode fibre interface. Tests fibre installations in local area networks. Fits in the slot on the back of DTX cable analyser (standard copper cable adaptors can be connected but not used simultaneously). Provides fibre testing and certification. Bi-directional testing at 1310nm & 1550nm at the same time. Measures optical power loss, length, and propagation delay for singlemode fibres. Pass/fail results based on common fibre standards. SC optical connectors. Includes in built visual fault locator (VFL).

LAN Cable Testers cont’d.Fluke DTX-SFM2 Single Mode Fibre Adaptor for DTX Cable Analyser

FLU,DTX-SFM2 (3265) AU/MYDTX1200/1800 single mode fibre interface.

Use for testing fibre installations in local area networks. Fits in the slot on the back of DTX cable analyser (standard copper cable adaptors can be connected but not used simultaneously). Provides fibre testing and certification. Bi-directional testing at 1310nm and 1550nm at the same time. Measures optical power loss, length, and propagation delay for single mode fibres. Pass/fail results based on common fibre standards. SC optical connectors. Includes in built visual fault locator. (VFL)

LAN/WAN AnalysersEXFO AXS-200-850 Ethernet Test SetEXF,AXS-200_850 (3228) AUTwo AXS-200/850(s) for installing, tuning up or maintaining Ethernet and IP services up to 1Gbit. Bidirectional RFC 2544 testing. Applications include performance assessment of Carrier Ethernet services, activation and maintenance of metro Ethernet networks, deployment of active Ethernet (point-to-point) access services, traffic generation and

monitoring for network performance testing Bit-error-rate testing (BERT) up to layer 4. Pass/fail results with user-defined thresholds. QoS, ToS and diffserv capabilities. Copper and SM & MM fibre interface supplied.

EXFO ETS-1000L 10/100/1000 Ethernet LoopbackEXFO,ETS-1000L MYEthernet/Gigabit ethernet loopback unit ETS-1000L is intended for performing loopback at the physical, data link, network and transport layers of the OSI model. It allows carrying out loopback control via OAM protocol and remote control via TELNET protocol.

EXFO FTB-860G NetBlazer10G Ethernet TesterEXF,FTB-860G (3223) AUPerforms 10 Gbps RFC 2544 measurements and EtherSAM (ITU-T Y.156sam), for turnkey deployment, validation, and troubleshooting of

access and metro ethernet services. IPv6 testing capabilities BERT, RFC, traffic gen and through mode. NetBlazer offers GUI navigation, dedicated quick-action buttons, and clear notifications for accurate interpretation of test results.

Fluke Networks Etherscope II Gigabit LAN AnalyserFLU,ETHERSCOPE-EX (3226) AU10M/100M/1Gigabit Copper, Fibre and WLAN a/b/g network analyser. Discover network elements and fault location even in a switched environment. IP analysis of Carrier Ethernet services. VLAN

discovery, connected host details and trending data. Document and report network performance. View detailed information about RF signal strength, APs, SSID, channel information and more. Cable ID accessory for tracking cable routes included.

Fluke Optiview Pro Gigabit 10/100/Gigabit LAN AnalyserFLU,OPTIVIEW-GIG (3227) AUProvides network analysis on 10/100/Gigabit ethernet networks (multimode fibre & copper). Features active discovery in switched networks, full 7 layer analysis, ITO (Internetwork Throughput Option), trace switch

route, free string match, reporting and documenting, address-to-name mapping, packet capture and decode, SNMP device analysis, RMON II traffic analysis, application level traffic analysis and much more.

LAN Cable Testers

Data & Telecommunications www.techrentals.com.au

Page 23: normas quipment-solutions-guide

7” 12 HOURS 1sec 2Gb

iOLM Ready: Turn complex OTDR analysis

into a one-touch task

Outdoor-enhanced touchscreen

Intuitive, Windows-like GUI

Improved navigation and performance

Rugged enough for any OSP

environment

Never-let-you-down battery life

Ready to test in 1 second

Store up to 20 000 traces

(bellcore)

COMPACT.POWERFUL.INTUITIVE.Introducing Uncompromising Tablet-Inspired Handheld OTDRs, the MAX-700B series.

Three models to cover the most common fi ber test applications

www.EXFO.com/MaxOTDR

› MAX-715B Last-Mile OTDR › MAX-720B Access OTDR › MAX-730B FTTH/PON OTDR

LAN/WAN Analysers cont’d.JDSU SmartClass 10M-1G Ethernet TesterJDSU,CSC-ETHTR-PC (3249) AUSmartClass Ethernet for comprehensive installation, turn up and maintenance of Ethernet IP services up to 1 Gbit. Performs Bidirectional RFC 2544, Asymmetric RFC and multiple streams testing. Applications include performance assessment of Carrier Ethernet services, activation and maintenance of metro Ethernet networks, deployment of active Ethernet (point-to-point) access services, traffic generation and QoS verification.

JDSU SmartClassEthernet 10M-1G Ethernet TesterJDSU,SMARTCLASS-ETH (3220) AUTwo SmartClass Ethernet(s) provided for comprehensive installation, turn up and maintenance of Ethernet IP services up to 1 Gbit. Performs Bidirectional RFC 2544, Asymmetric RFC and multiple streams testing. Applications include performance assessment of Carrier Ethernet services, activation and maintenance of metro Ethernet networks, deployment of active Ethernet (point-to-point) access services, traffic generation and QoS verification.

PDH/SDH AnalysersJDSU ANT 5 SDH/PDH Access TesterJDSU,ANT5-STM4 (3445) AU/MYField tester for the installation, commissioning and fault finding of fibre and copper SDH/PDH networks. Electrical interfaces for PDH/SDH: E1, E3, DS3, E4, STM-0e/1e; Optical interfaces for SDH/SONET: STM-1/OC-3, STM-4/OC-12.

BERT, round trip delay measurement, error performance analysis: G.821, G.826, G.828, G.829, M.2100,M.2101 and ANSI. Autoconfig functionality for automatic traffic detection, line rate, structure and mapping. Offline Viewer SW provides result analysis and report generation.

PDH/SDH Analysers cont’d.JDSU ANT 5 SDH/PDH Access TesterJDSU,ANT5-STM16 (3446) AU/MYSField tester for the installation, commissioning and fault finding of fibre and copper SDH/PDH networks from 1.5Mb/s to 2.5 Gb/s. Optical testing at dual wave lengths at STM-1, STM-4, and STM-16. Electrical testing at DS1/E1/E3/DS3/E4 and STM-1 interfaces. Full analysis of concatenated mappings. ATM analysis for service verification of ATM and 3G/UMTS networks.

JDSU EDT-135 E1 and Data TesterJDSU,EDT-135 (3450) AU/MYField service tester for commissioning, maintenance and troubleshooting of E1 PCM2Mbps and V.11/RS-442, V.24/RS-232, V.35,V.36/RS-449, EIA-530 data circuits operating at 50bps to 2Mbps. Provides framed & unframed monitoring, end-to-end testing, drop

& insert, channel associated signalling; error & alarm analysis, S bit, NFAS & NMFAS monitoring & generation. Round trip delay measurement, G.821, G.826 & M.2100 quality of service measurements. Signal level measurement & primary multiplexer testing.

Acterna MTS 8000/T-BERD Transport ModuleJDSU,MTS8000 MYMultirate interface for PDH-DS1/DS3/E1/E3/E4,STS-1 OC-3/12/48/48, STM-1e/1/4/16 and interface for OC-192 STM-64 with the ability to monitor down to the STS-1 level inside of any supported optical rate. Used for verifying and qualifying the performance of SDH and Gigabit ethernet, telecommunications networks. Electrical and optical interfaces at rates 1310/1550nm). Also supports the NewGen (ethernet over Sonet/SDH) and able to perform RFC2544. Ethernet IP testing with 10/100/100Mbps electrical RJ-45 Interfaces. Supports VLAN, Q-in-Q,VPLS,MPLS Tunnelling application. Comes with touch screen GUI operation. Measures optical power and frequency. Floppy drive installed.

Data & Telecommunicationswww.techrentals.com.au

Page 24: normas quipment-solutions-guide

22

Light Sources & Power Meters cont’d. Fluke FTK1000 Multimode Fibre Optic Light Source & Meter FLU,FTK1000 (3365) AU

Light source is multimode 850nm and 1300nm. Power meter has 850/1300nm multimode and 1310/1550nm single mode. Manage results and print reports via Power meter memory, PC and supplied software.

Fluke FTK150 Optical Fibre Light Source/MeterFLU,FTK150 (3366) AU

Fibre test kit. Light source is multimode 850nm and 1300nm. Power meter has calibrated measurements at 850/1300nm multimode and 1310/1550nm single mode. +3dBm to -55dBm measurement range with 0.01dB resolution. Manage results and print reports via Power meter memory, PC and supplied software. Supplied with various connectors and patch leads.

JDSU/Acterna OLA-55 Single Mode Optical AttenuatorJDSU,OLA-55 MYAdjustable wavelength from 1260 to 1650nm (1nm increments). Calibrated wavelengths 1310nm, 1550nm & 1625nm. Maximum permitted level =23dBm. Optical Interface: FC-PC.

JDSU OLP-55 Optical Power MeterJDSU,OLP-55 MYOptical Power Meter BN 2277/01 Power & Loss Measurement for installation, maintenance and repair of fiber optics networks. Display Range: -70 to +20dBm, calibrated wavelengths: 850, 1310, 1550 & 1650nm. Optical connection: FC.

JDSU OLSP-55 Optical Laser SourceJDSU,OLS-55 MYOperates on dual wavelength of 1310nm and 1550nm. Output power is from -7 to 0 dBm. Optical Interface: FC-PC.

Kingfisher KI-28010 Single Mode APC Light Source and KI-7600 Power Meter

KIN,KI28010-2600 (3361) AUSinglemode light source KI-28010 and power meter KI-2600. Compatible with APC and PC singlemode networks. Wavelengths 1310, 1550 and 1625nm. Memory with text, timestamp and USB dump, real-time PC reporting software. Autotest provides fast, easy and automatic multi wavelength loss testing.

Kingfisher KI78010 Single Mode APC Light Source and KI7600 Power MeterKIN,KI78010-7600 (3360) A U

Light source (KI78010) and power meter (KI7600) optical fibre test set for single mode network and DWDM testing at 1310, 1550 and 1625nm. LS (KI78010) has Angled SC, FC and ST interchangeable connectors. PM (KI7600) with

InGaAs detector has large user memory and flexible real-time PC reporting software. Autotest provides automatic multi wavelength loss testing. Power meter can be used for multiple single and multimode wavelengths.

Kingfisher KI7822B- KI7600A Single Mode Light Source & Power MeterKIN,KI7822B-7600A (3362) AU

Light source (KI7822B) and power meter (KI7600A) optical fibre test set for single mode applications (1310nm and 1550nm). Power meter has large user memory and flexible real-time PC reporting software. Autotest provides automatic

multi wavelength loss testing. The meter displays mW, μW, nW, dB, dBm to 0.01dB resolution, with no range changing delays. Power meter can be used for multiple single and multimode wavelengths. Laser output power 0dBm.

PDH/SDH Analysers cont’d.JDSU SmartClass E1/Datacom TesterJDSU,SMARTCLASS-E1-D AUJDSU,SMARTCLASS MY

Handheld field tester for the installation and commissioning of E1 and Datacom services. Applications include (not limited to), G.703 - 2Mb/s testing, 2 M (Bulk), n x 64kb/s BERT, audio monitoring (VF drop & insert),ABCD/Sa monitoring, alarms (defects) and errors (anomalies) insertion,round-trip delay, DTE / DTE emulation and monitor mode. Interfaces with X.21, V.24 (RS-232), V.35, V.36 (RS-449), and EIA-530.

VeEx VePal TX130E+ DSn/PDH/Ethernet Analyser VEEX,TX-130E+ MYFull-featured Mobile test solution supporting legacy PDH/DSn and Carrier Ethernet technologies. Provides E1 and 1G Ethernet Testing according to RFC2544 standards.

VeEx VePal TX130M+ DSn/PDH/Ethernet Analyser VEEX,TX-130M+ MYFull-featured Mobile Backhaul test solution supporting legacy PDH/DSn, Carrier Ethernet technologies, and Synchronized Packet networks. The unit is capable of emulating both Master and Slave clocks according to ITU-T G.8261 SyncE and IEEE 1588v2 standards. At the same time able to provide E1 and 1G Ethernet Testing according to RFC2544 standards. It has options of Pulse Mask, E1 Wander and MTIE&TDEV.

VeEx VePal TX130+ E1 /Datacom TesterVEEX,TX-130+ MYHandheld field tester for installation and commissioning of E1 and Datacom services. It is a small and compact unit.

DSL/POTS Test SetLine and DSL Test SetFLU,990DSL 2/2+ (3470) AUCopperPro broad range Plain Old Telephone

Services (POTS) troubleshooting, fault location and line qualification capabilities. Includes Wideband/TDR option which adds high frequency transmission testing and qualification functions for services like ADSL 2/2+, VDSL, HDSL, HDSL2 & 4, ISDN, T1, E1 and DDS. TDR feature adds precise fault location and analysis. Includes TN2100 remote terminator.

Light Sources & Power MetersEXFO PPM-350B-EG PON Power MeterEXFO,PPM350B MYOptimiSed for FTTx E & GPON. PPM350B has 10 user-definable threshold sets, each set consisting of three wavelengths (1310, 1490 and 1550 nm) having their own pass/warning/fail analysis features. Simultaneous measurement and display of all PON signals voice, data and video.

EXFO PON/FTTx Power Meter & Inspection Probe EXF,PPM352_FIP400 (3370) AU Kit includes PPM-352B-EG-ER optimized for FTTx E & GPON & FIP-400 inspection probe with handheld display. PPM352 has 10 user-definable threshold sets, as well as pass/warning/fail analysis features. Simultaneous measurement and display of all PON signals voice, data and video.

Data & Telecommunications www.techrentals.com.au

Page 25: normas quipment-solutions-guide

23

Fusion SplicersFitel S123M12 Ribbon Fusion Splicer FIT,S123M12 (3312) AUHand-held fusion splicer, can splice from 1 to a maximum of 12-ribbon fibre. Protection sleeve shrink time is 35 seconds for ribbon fibre sleeve, while splicing requires only 15 seconds for 8 or 12 ribbon fibre allowing up to 160 splicing cycles (splicing/heating) using the 2 battery packs installed in the main body. Includes S325 cleaver and thermal jacket stripper.

Fitel S178 Fusion Splicer and S325 CleaverFIT,S178_S325 (3314) AU S178 hand-held, core-alignment fusion splicer and S325 cleaver. Splicer provides typical losses of 0.02dB and 0.01dB on single and multimode fibre respectively. 7 second splice time, built in heater and tension test. Can be operated from battery or AC source. Precision fibre cleaver can be used with single & multimode fibres and features a built in sharps collection bin that automatically stores fibre off-cuts.

Fujikura FSM60R Ribbon Fusion Splicer, Cleaver, Stripper

FUJ,FSM60R-CT30 (3310) AURibbon fibre fusion splicer, will splice from 1 to 12 fibres. Splice time 20 sec, sleeve shrink time 40 sec, typically. Detachable work table and arc-free calibration system. Includes CT-30 fiber cleaver and thermal jacket stripper.

Fujikura FSM60S Splicer & CT30 CleaverFUJ,FSM60S-CT30 (3320) AU/MYTypical splice losses of 0.02dB and 0.01dB on single and multimode fibre respectively. Features splice protection heater, detachable work table and arc-free calibration system.

Fujikura FSM70S Core Alignment Fusion Splicer

FUJ,FSM70S (3318) AUSingle fibre core alignment fusion splicer and CT30A cleaver. Typical splice losses of 0.02dB and 0.01dB on single and multimode fibre respectively. Automated tension test, wind and heater cover, 7 second splice time and 14 second heat time.

OTDR & Fibre Inspection

See also LAN Cable Testers on page 20

Anritsu CMA 4500 Single & Multimode 5/25dB OTDRANR,CMA4500SM-MM (3338) AU

Single mode and multimode OTDR. Includes wavelengths multimode 850/1300nm (24/26dB) and single mode 1310/1550 (35dB). Single mode port is SC/APC. Ethernet, USB connectivity, 20GB HD and PS2 ports. Touch screen and hard key interfaces.

OTDR & Fibre Inspection cont’d.Fluke Optifiber Pro Multimode OTDRFLU,OPTIFIBER-PRO-MM (3343) AU

MMultimode OTDR, wavelengths 850 and 1300nm. Designed for testing, troubleshooting and certifying multimode 50 and 62.5um fibre optic networks. Smartphone user interface, shortest event and attenuation deadzones, LinkWare download and reporting software included.

Fluke Optifiber Pro Quad OTDRFLU,OPTIFIBER-PRO Q (3344) AUMulti and singlemode OTDR,

wavelengths 850, 1300, 1310 and 1550nm. Designed for testing, troubleshooting and certifying multi and singlemode 62.5, 50 and 9um fibre optic networks. Smartphone user interface, shortest event and attenuation deadzones, LinkWare download and reporting software included.

JDSU Fibre Inspection-Capture ProbeJDSU,FIBER_INSPECT (3340) AU Handheld display, dual magnification (200/400x) probe and USB adaptor for fibre end-face image analysis and capture. Includes software and various probe tips.

JDSU MTS-4000 OTDR with E4136FCOMP-MA

JDSU MTS-4000-FCOMP (3334) AU Maintain metro and PON-based FTTx networks. 1310, 1550 and 1625nm wavelengths at 42, 40 and 40 dB dynamic range (respectively), includes

power meter, VFL, NBN auto test sequences and fibre inspection probe. Performs insertion loss (IL), optical return loss (ORL) and OTDR from one optical port. Applications include bidirectional testing, trouble shooting and acceptance testing.

Fibre Optic LaunchCables & Patch Leads

Launch Fibre Multimode 50μm 100mFIB,LAUNCH MM 50UM (3380) AU100 metres of 50μm fibre terminated with SC connectors. A launch fibre enables an OTDR to measure the loss of the first connector and adapts a 62.5μm OTDR to a

50μm network.

Launch Fibre Multimode 62.5μm 300mFIB,LAUNCH MM 62.5UM (3382) AUSC to SC multimode 62.5μm launch fibre.

Launch Fibre Single Mode 9μmFIB,LAUNCH SM 9UM (3378) AUSingle mode 9μm SC launch fibre.

Data & Telecommunicationswww.techrentals.com.au

Fibre optic consumables available for sale. Please ask for delivery when placing your rental order.

Page 26: normas quipment-solutions-guide

24

Cable & Pipe Tracers & Fault LocatorsElectrical TestersPAT Testers & RCD TestersMicro-Ohm Meters & Earth TestersPower Analysers, Loggers & RecordersCurrent Clamps Probes & AccessoriesInsulation Testers & Meggers to 20kVOil, Hipot & VLF Testers above 20kVCircuit Breaker TestersTransformer TestersCurrent InjectorsProtection Relay Testing SystemsAC Sources/Inverters/GeneratorsPower Transformers & VariacsBattery Management Systems

See also Ground Penetrating Radar on page 61 See also Underground Services Location on page 61

CScope CATXDSGV-KIT Cable and Pipe LocatorCSC,CATXDSGV-KIT (3730) AU/MYIndustry standard locator used to determine the exact location of buried pipes and cables. Functions include: Power mode for detecting live imbalanced cables to a depth of 3m. Radio mode for detecting re-radiated radio signals to a depth of 2m. Generator mode for detecting conductors carrying the signal generated by the C.Scope signal generator.

Fluke Cable LocatorFLU,2042 (3602) AUIdeal for tracing cables in walls and underground, locating fuses/breakers on final circuits as well as locating interruptions and short-circuits in cables and electrical floor heating systems. Can be used for tracing metallic water and heating pipes. Supplied as a kit comprising a transmitter and receiver in a carry case. Voltage measurement range

12 to 400 volts. Frequency range 0 to 60Hz. Transmitter output signal 125kHz. Transmitter voltage 0 to 400V ac/dc. Depth location 0 to 2.5m. Receiver voltage detection range 0 to 0.4m. The receiver incorporates a torch for working in dimly lit locations.

Cable & Pipe Tracers & Fault Locators cont’d.

Megger MPP1002 Cable Fault Pinpoint LocatorMEG,MPP1002-FAULT PP (3603) A U Pinpoints faults in shielded and direct buried primary cables via Geophone probe(s). Can be used with any surge generator (thumper). Stand-alone unit measures electromagnetic surge

and supplies the amplitude of that surge which aids in finding the fault. When fitted with probes the unit will detect the acoustic discharge (thump), measure the time delay between acoustic and electromagnetic signals and calculate the distance to fault. Using the dual probe system the direction to fault is indicated. Detects faults up to 23m away. Battery powered.

Megger TDR20002RM Dual Channel TDR Cable Fault LocatorMEG,TDR2000/2RM (3605) AUTime Domain Reflectometer cable fault locator. User selectable ranges from 0 to 50m up to 20km, minimum resolution 0.1m. Dual cursor measurement. Internal memory for 15 traces. Megger “Tracemaster” software supplied. RS232 interface for PC communications. High resolution LCD display. Battery powered. Dust and shower proof to IP54.

Riser Bond 1205T-OSP Metallic TDR Cable Fault LocatorRB,1205T-OSP MYDual input metallic time domain reflectometer cable fault locator for coaxial cables. Maximum Range: 63,700ft (19,400meters) at .990 VOP. Distance Accuracy: ±0.1ft (0.03m) plus ±.01% of reading. Can store, recall and download waveform, via RS232 cable. (Viewable with Software.)

Electrical Testers See also Current Clamps Probes & Accessories on page 31-32

ABB CB-2000 Portable Capacitance Meter

ABB,CB2000 (3500) AUPortable (2.4kg) capacitance meter (0 - 1000μF) which allows individual capacitors in a capacitor bank to be measured without disconnection. Battery powered with an ac adapter. Approximately 8 hours operating time between charges. Supplied software and drivers allow measured values to be exchanged to and from a PC via supplied USB cable. Data stored as tab delimited text files.

Hioki 3283 Clamp on Leak HiTesterHIO,3283 MYMonitor leak current fluctuations. Bandwidth 5Hz to 15kHz. AC current range 10mA to 200A, resolution 10microA. Accuracy ±1%. LCD display. Battery powered.

Martindale Phase Sequence & Continuity Indicator 100 to 600V, 50/60HzMAR,PSCI424-585 (3502) AUCheck the presence and sequence of the phases on 3ph circuits. Provides a visual indication of loss of phase or incorrect sequence. Supplied in 2 forms. Probe style; the connection to the tester is via 3 insulated cables to 3 fused test probes, 1 with an insulated crocodile clip. Plug style; a 16A, 4 pin (3ph & earth, BS4343) plug is fitted to the tester. Use as a socket tester prior to plugging in 3ph equipment.

Cable & Pipe Tracers & Fault Locators

Electrical Power www.techrentals.com.au

The fi lm symbol indicates there is a ‘how to video’ online for that product, see page 1.

Page 27: normas quipment-solutions-guide

25

PAT Testers & RCD TestersMegger RCDT330 Residual Current Device TesterMEG,RCDT330 (2618) AUTests standard, DC, selection and programmable RCDs. Ramp testing. Auto (remote) testing. Auto sequence test feature. 3ph safe. Enables testing on 110V centre tapped supplies. Performs 1/2I, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, 300mA, 500mA & 1,000mA on general and selective (time delayed) RCDs. Weatherproof to IP54. USB interface for test results download.

Metrel IT3017- Installation Tester for Testing to AS/NZS3000MET,IT3017INSTALTEST (2610) AUMultifunction installation tester with measurement functions and Pass/Fail limits set to AS/NZS3000 Wiring Rules. Capable of storing test results for printing compliance

test reports. In-built Australian measurements and Pass/Fail limits, and guarantees accountability and traceability with storing of test results. Simply conduct the test, press the Memory button to save the result and assign the result to a location, then download results to PC software and print-out compliance test reports with actual test results. Earth Continuity & Resistance, Insulation Resistance, Polarity, Correct Circuit Connections, Fault Loop Impedance and RCD Testing. “Auto-Sequence Test” mode further speeds up compliance testing and reporting.

Seaward PAC 3760 Appliance CheckerSEW,PAC3760 (2605) AUPerforms the following tests in conformance to AS/NZS 3760:2000; earth bond, insulation & polarity tests, leakage current tests for Class I & Class II appliances and leads (leakage current testing of appliances, which requires power to “switch” them on, is the method required by AS/NZS3760:2003). Simple pass/fail indication. Unique 3 button operation. Class I, class II and leakage current.

Automatic test sequence senses an IEC or or extension lead then performs a polarity test. Detects that the appliance under test is switched “On”. Earth bond test is set at 10A and is capable of fusing a poor earth.

Seaward ProTag OPTIMA-300 Testing and Tagging SystemSEW,PT-300 (2603) AU

Comprises the Seaward PrimeTest 300 appliance and RCD tester, ProTag Optima test tag printer and the BCS-Blue bar code scanner. Battery powered, weighs around 2kg. Carries out all of the tests required under AS/NZS3760 for appliances and leads, and 30mA RCD tests. Operates as a handheld data logging device by recording any type of test, inspection or risk assessment with user defined

inspection routines and an in-built library of measurement and engineering units for recording actual results.

Seaward Supernova XE3760+ PAT System with Printer and ScannerSEW,XE3760PKIT+ (2600) AU/MY

Includes results label/tag printer and barcode scanner. Performs all AS/NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx. 100W) and 250VDC MOV

insulation resistance tests. Stores 5,000 tests in internal memory by appli-ance ID, including test type, detailed results, test time & date, next test due date, site & location. Calibrated resolution better than the required 5% of FS across all ranges as specified by the Standard. Full QWERTY keyboard, and bar code reader for input. Durable plastic adhesive test label/tags printed to attach to appliances and leads includes user ID (logo optional on request) and test barcode ID, saves transcription. Compatible with Seaward PATGuard plus software package.

Micro-Ohm Meters & Earth TestersFluke 1623 KIT GEO Earth Ground TesterFLU,1623-KIT (2655) AU

Measure total earthing resistance (RA) with 2, 3 or 4-pole Fall of Potential method and selective earth resistance measurement (0.001Ω to 19.99 kΩ). Stakeless ground loop measurements (0.001Ω to 199.9Ω). Battery powered.

Fluke 1625 KIT GEO Earth Ground TesterFLU,1625-KIT (2650) AUMeasure total earthing resistance (RA) with 3 or 4-pole Fall of

otential method, selective earth resistance measurement and 4-pole soil resistivity testing (0.001Ω to 19.99kΩ). Stakeless ground loop measurements (0.001Ω to 199.9Ω). Includes automatic frequency control to minimise interference effects. Battery powered.

Fluke 1630 Earth Ground ClampFLU,1630-EARTH CLAMP (2651) AU/MYEarth ground loop testing and continuity testing without

breaking the circuit. Ground loop resistance range 0.025Ω to 1.5KΩ. Ground leakage current measurement range 0.2mA to 1000mA. Current measurement range 0.2A to 30A. Logs and stores measurements for on screen recall. LCD display. Battery powered.

Fluke Clamp for Ground Loop Resistance around Power PylonsFLU,EI-162BN (2652) AUSplit core transformer designed to work with the Fluke 1623 and Fluke 1625 earth ground testers to make selective earth ground loop resistance measurements on power pylons. Inner diameter of the clamp is 310mm.

Megger High Accuracy Configurable Diagnostic Earth TesterMEG,DET2/2 (2653) AUProvides a wide resistance range from 0.01Ω to 19.99kΩ for testing larger or more complex grounding systems and for difficult testing

environments, with ±0.5% accuracy and 0.001Ω resolution. Microprocessor control and advanced filtering simplify testing in environments with high levels of interference.

Megger DET20C Digital Earth Test ClampMEG,DET20C (2654) AUMeasures ground resistance from 25mΩ to 1,500Ω. Measures ground leakage current from 200μA to 35A. Automatic self calibration. Auto ranging. High and low alarms. Large memory. Download to Megger Download Manager. Measures earth resistance in installations such as buildings, pylons and RF transmitter sites. Use for the inspection and verification of lightning protection systems. Large jaw opening.

Megger DET4TC2 Digital Earth Tester With KitMEG,DET4TC2 MYMeasurement range of 0.010Ω to 200kΩ, ground noise voltage measurement from 1V to 100V and ground current from 1mA to 20A. Accurate results can be obtained in electrically noisy environments since it is capable of rejecting noise voltages of 40V

peak to peak and the user can select different test frequencies to minimise the effect of interference. Powered from 8 AA batteries. Supplied with ICLAMP. Auguments the traditional fall-of potential measurement traditional fall-ofpotential measurement method with ART (Attached Rod Technique) which allows electrode testing without disconnection and also leakage current measurements down to 1mA. The VCLAMP enables true stakeless measurements to be made in situations where driving stakes is not practical.

Electrical Powerwww.techrentals.com.au

Page 28: normas quipment-solutions-guide

26

Offi ces Sydney – Melbourne – Brisbane – Perth

Page 29: normas quipment-solutions-guide

27

Power Analysers, Loggers & Recorders See also Current Clamps Probes & Accessories on page 31-32

CHK GridSense PowerMonic PM20 Power Quality AnalyserCHK,PM20 MY

Three phase, weatherproof IP65 field unit. Three voltage channels 63V to 440V (isolated). Four current channels 0 to 3kA RMS (3ph & neutral). Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and 500A for neutrals

clamp-on CTs are available. Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and tariffs, high speed RMS waveform capture events outside preset limits (10ms intervals). Software provides graphs and summaries to PC. Download files while logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is required with the CHK POWERview software to configure this unit before operating.

CHK Gridsense Powermonic PM30 Power Quality AnalyserCHK,PM30 (8705) AU/MY

Weatherproof IP65 field unit. Channels 3 voltage, 63V to 440V (isolated), 4 current 0 to 3kA (3ph & neutral) RMS. Supplied with 3 x 1kA clamp-on CTs (cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors and 500A & 100A for neutral conductor current measurement are available. Memory 4Mb.

In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs, max demands, transient and sub-cycle disturbances. Software provides graphs and summaries to PC. Download files while logging via RS232 interface. PC using Win 95, 98, NT4, 2000, XP, O/S, is required with the CHK POWERview software to configure this unit before operating.

CHK GridSense PowerMonic PM30 Plus Power Quality AnalyserCHK,PM30PLUS (8706) AU/MY

Weatherproof IP65 field unit. Channels: 3 Voltage, 63V to 440V (isolated). 3 current 0 to 3,000A (3ph) rms. Supplied with 3 flexible 3,000A clamp-on CTs (flexible CT length 600mm and 190mmØ). In addition, clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A for neutral conductor current measurement are available. Memory: 4Mb. Inbuilt two line LCD display. Records: V, A, pf, f(Hz), kVA, kVAr,

kW, harmonics, (THD and individual to 48th). Total energy, tariffs, maximum demands, transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging RS-232 interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required with the CHK POWERview software to configure this unit before operating.

CHK GridSense PowerMonic PM35 Power Quality AnalyserCHK,PM35 MY

Power logger and disturbance analyser. Weatherproof IP65 field unit. 3 Voltage (55VAC to 520VAC) and 4 current (0 to 3,000A) channels. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and 190mmØ). Memory: 15Mb. Inbuilt two line LCD display. Records: V, A, pf, f(Hz), kVA, kVAr, kW, harmonics,

(THD and individual to 48th). Flicker (Pst & Plt), Total energy, tariffs, maximum demands, transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Downloads files while logging. High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP (Vista in compatability mode)O/S, is required with the software to configure this unit before operating.

Micro-Ohm Meters & Earth Testers cont’d.

Megger DLRO10 Micro-Ohm MeterMEG,DLRO10 (2661) AUSelf contained fully automatic micro-ohm meter, selecting the most suitable test current up to 10Adc. Range 0.1μΩ to 2kΩ, resolution 0.1μΩ. LED display. Rechargeable battery.

Megger DLRO10X Digital Low Resistance Ohm Meter 10A/0.1μΩ-2KOhmMEG,DLRO10X (2633) AU/MYSelf contained fully automatic (with manual option) micro-ohm meter, selecting the most suitable test current up to 10Adc. Range 0.1μΩ to 2kΩ, resolution 0.1μΩ. Internal memory for 700 tests. Download software supplied. RS232 communications to PC. LCD display. Rechargeable battery.

Megger DLRO200 200A Micro-Ohm MeterMEG,DLRO200 (2664) AUTest current range 10A to 200Adc. Measurement range 0.1mΩ to 1Ω, resolution 0.1mΩ. Current cables 2 x 5m. Internal memory for 300 tests. Download software supplied. RS232 communications to PC. LCD display.

Megger DLRO600 Digital Micro-Ohm Meter - High currentMEG,DLRO600 (2665) AU/MYTest current range 10A to 600Adc. Measurement range 0.1μΩ to 1Ω, resolution 0.1μΩ. Current cables 2x5m. Internal memory for 300 tests. Download software.

Megger DLRO Wind Turbine Lightning Protection Test Lead SetMEG,DLRO-100LEAD (2662) AUFor Megger DLRO 10 series digital microohm meters. Specially designed for measuring resistance of lightning protection circuit between wind turbine blade tip and ground. Kelvin clip and hook ends on 100m cable reel. 5m DH2 lead with duplex hand spikes and hook end.

Megger DLRO Lead Set Current & Voltage LeadsMEG,DLRO-LEADSET (2666) AUFor Megger DLRO digital micro-ohm meters. Potential spike lead set x2 and current clip lead set x2. Leads are used to separate the C & P connections. This avoids the erroneously high readings taken due to a high resistance contact. Current clip lead set 2m (242041-7) and potential spike set 2m (242021-7).

Megger MOM2 Micro-Ohm MeterMEG,MOM2 (2638) AU

Lightweight (1kg), handheld micro-ohm meter. Up to 220A test current, autoranging from 999μΩ to 1000mΩ FS. Rechargable batteries provide 2200 measurements for Imin = 50A, or 800 for Imin = 100A. Memory for 190 recorded measurements, downloadable via Bluetooth with provided software. Kelvin probes included.

Electrical Powerwww.techrentals.com.au

New items are being added to the inventoryconstantly, so if you do not see what you arelooking for please call 1800 632 652.

Page 30: normas quipment-solutions-guide

28

Power Analysers, Loggers & Recorders cont’d.

CHK GridSense PowerMonic PM40 Power Quality AnalyserCHK,PM40PQA (8708) AU

Weatherproof IP65 field unit. Channels: 3 Voltage, 63 to 440V (isolated). 4 current 0 to 3,000A (3ph and neutral) RMS. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and Diameter 190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current imbalance (THD and individual to

48th ) and Flicker. Total energy, tariffs, maximum demands, and transient and sub-cycle disturbances. Included software provides graphs and summaries to PC. Download files while logging USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required with the CHK PowerView software to configure this unit before operating.

CHK GridSense PowerMonic PM45 Power Quality AnalyserCHK,PM45 (8709) AU

Suitable for low voltage investigations, power profiling and load studies, harmonic analysis,power factor studies & flicker and imbalance monitoring. Features IEC61010 Cat IV 600V safety certificate, weatherproof IP65 case, 4 channel voltage and 4 channels current. Supplied with 4 x Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd 0 to 60VAC, Current input 0 to 3,000A.

Dranetz-BMI Power Guide 4400DRA-BMI,PG4400 (8715) AUProvides the full range of

measurements including V, I, W, VA, VAR, TPF, DPF, demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum (V, I, W) to the 63rd, fl icker (Pst, Plt), crest

factor, K factor, transformer de-rating etc. Asset comes with AC fl exible current clamp DRA-BMI,RR3035A/24, current range 30/300/3,000A AC only. Can be extended to different ranges of measurement AC/DC by selecting appropriate current clamps. Has the full range of arithmetic, vector and sequence parameters to evaluate distorted and un-balanced loads as defi ned in IEEE 1459. Exceeding high/low limits of any active parameter can trigger logging. Voltage & current disturbances. DRA-BMI,PG4400 analysers can be used for power quality measurements, current inrush fault recording long term monitoring and continuous logging at 1s intervals. DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-4-30, AS61000-4-7 and AS61000-4-15.

Dranetz-BMI Power Xplorer PX5DRA-BMI,PX5 (8716) AUProvides the full range of

measurements include V, I, W, VA, VAR, TPF, DPF, Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum (V, I, W) to the 63rd,

Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/Avg values are determined in 1/2 cycle RMS steps. Complete with A/C Flexible Current Clamp DRA-BMI,RR3035A/24, Current Range: 30/300/3,000A AC only. Can be extended to mentioned different ranges of measurement both AC/DC by selecting appropriate current clamps. High-speed transient capture (1MHz sampling rate). Pre-event and post-event waveform capture cycles are user adjustable. Can be used for power quality measurements, current inrush (cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage logging), long term monitoring and continuous logging at 1s intervals. Compliant with IEC Standard 61000-4-30 (Class A), AS61000-4-7 and AS61000-4-15.

Power Analysers, Loggers& Recorders cont’d.

Fluke 345 Power Quality Clamp MeterFLU,345 (8739) AU

For measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems. Low-pass filter and high EMC immunity design make unit ideal for noisy environments. 600V CAT IV rated, 1400A AC, 2000A DC. Measure and log harmonics, inrush current and ripple current on battery systems. Analyse data and generate reports with included Power Log software.

Fluke 435 3-Phase Power Quality & Energy Analyser

FLU,435 (8738) AU/MYPower Quality Analyser to suit a broad range of ac mains studies. Includes 4 x 600/6000A ac CTs. A unique energy loss calculator provides the ability to monetarily quantify energy losses. Supplied with Fluke Power Log Software for detailed data analysis and report generation.

Fluke 1735 3-Phase Power LoggerFLU,1735 (8737) AU/MYMeasures single-phase to 3-phase 4-wire

circuits, 50/60Hz. 3 voltage inputs with common neutral rated 600Vac (CAT III 600V). 4 current inputs, 4 flexible current probes (15A to 3000A) are included.

Records voltage, current, power (P, Q & S), power factor, frequency, energy consumption, averaged demand, harmonics (odd up to 25th order), THD (voltage & current). Includes built-in batteries for up to 12 hours of recording, and includes Fluke Power Log software.

Fluke VR1710 Single-Phase Voltage Quality RecorderFLU,VR1710 (8720) AU

Single phase power quality analyser. Records RMS, transients, flicker & harmonics up to the 32nd. Selectable logging periods from 1s to 20min. Provides continuous recording with no gaps. Includes software for download, analysis and automatic reporting.

Hioki 3169-21 Clamp-On Power HiTester with 4 x 500A CTs

HIO,3169-21 CT500AMP (8726) AUMeasures voltage, current, power, power factor, harmonics and integrated values. Simultaneously performs demand

measurements required for power management and energy-saving. Range 0.05A to 500A. Includes 4 x clamp-on CTs. Supplied software provides graphs and summaries to PC. Flash card data storage. RS232 interface for PC communications.

Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000A CTsHIO,3169-21CT1000AMP (8727) AUMeasures voltage, current, power, power factor, harmonics and

integrated values. Simultaneously performs demand measurements required for power management and energy-saving. Range 5A to 1000A. Includes 4 x clamp-on CTs. Supplied software provides graphs and summaries to PC. Flash card data storage. RS232 interface for PC communications.

Electrical Power www.techrentals.com.au

Page 31: normas quipment-solutions-guide

29

Page 32: normas quipment-solutions-guide

30

Power Analysers, Loggers & Recorders cont’d.

Hioki 3169-21 Clamp-On Power HiTester with 4 x 5,000A FlexCTsHIO,3169-21CLAMPONPT (8728) AU

Measures voltage, current, power, power factor, harmonics and integrated values. Simultaneously performs demand measurements required for power management and energy-saving. Range 5A to 5000A. Includes 4 x flexible CTs, 500/5000A switchable. Supplied software provides graphs and summaries to PC. Flash card data storage. RS232 interface for PC communications.

Hioki 3196 Power Quality Analyser with 4 x 5,000A Flex CTsHIO,3196-PQA (8729) AU/MY

High speed field unit, measuring transient and sub-cycle disturbances, total energy, tariffs and max demand. Voltage (150~600V RMS), and 4 current (0

to 5kA), channels. Includes 4 x flexible CTs, 500/5000A switchable. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, and flicker. Memory 512MB flash card. Colour display. Supplied software provides graphs and summaries to PC. RS232 or LAN interface for PC communications.

Power Analysers, Loggers & Recorders cont’d.

Hioki 3196 Power Quality Analyser with 4 x 1,000A CTsHIO,3196PQA-CT1000A (8730) AU

High speed field unit, measuring transient and sub-cycle disturbances, total energy, tariffs and max demand. Four voltage (150~600V RMS), and 4 current (0 to 1kA), channels. Supplied with

4 clamp-on CTs. Memory 512MB flash card. Colour display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, and flicker. Supplied software provides graphs and summaries to PC. RS232 or LAN interface for PC communications.

Hioki 3197 Power Quality Analyser with 3 x 500A CTsHIO,3197PQA (8731) AU

Comprehensive portable PQA. Monitor for: inrush current, voltage swell, voltage dips, transient over-voltage and interruptions. Measure and re-

cord: power and power factor, active/reactive energy, demand, load changes (with graph display), voltage and current. Measures impulsive voltage quality: transient over voltage (impulse). RMS voltage quality: voltage swell, voltage dips, voltage interruption. Power quality: frequency, voltage, current, current peak, active/reactive/apparent power, power factor (displaced power factor). Three phase quality: voltage unbalance ratio, current unbalance ratio. Harmonic quality (up to 50th order): harmonic voltage, harmonic current, harmonic power, harmonic voltage/current phase angle, total harmonic voltage distortion, total harmonic current distortion (THD-F, THD-R).

Electrical Power www.techrentals.com.au

QUALITY PRODUCTSQUALITY RESULTS

Power Analysis

Data Logging

Power Parameters Pty Ltd83 Northern Road, Heidelberg West, Vic 3081

www.parameters.com.au [email protected]: 1800 623 350 Freefax: 1800 067 263

LR8410-20 Memory HiLoggerIR5001 Temperature Humidity Logger

PW3360-20 Power AnalyserPW3198 Power Quality Analyser

NEW

Cat IV 600V

Class A

Save your time and reduce your real costs with our Setup and Download service on page 37

Page 33: normas quipment-solutions-guide

31

Power Analysers, Loggers & Recorders cont’d.

Hioki PW3198 Power Quality Analyser with 3 x 1000A AC CT & 1 x 200A AC/DC CT

HIO,3198 (8732) AUPremium Power Quality Analyser for demanding

applications. Includes 3 x 1000A ac CTs and 1 x 200A AC/DC CT. Ideal for ac mains studies as well as solar inverter evaluations. Supplied with Hioki 9624 PQA-HiVIEW Software for detailed data analysis and report generation.

Metrix MX2040 AC/DC Clamp-on MeterMET,MX2040 (8745) AUMeasures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance. Ranges 200A & 2kA, 600V & 1kV, 20kW, 200kW & 2MW & kWH. Scale length 3,000. Single and 3ph operation. Motor rotation indication. Peak, min, max, average, RMS, and crest factor indication. Peak response time 1μs. Analogue output option fitted giving dynamic signals and calculated parameters (energy, etc). Jaw opening 55mm for 22 x 64 bars.

Current Clamp Probes & Accessories See also Electrical Testers on page 24 See also Power Analysers & Recorders on page 27-31

CHK 3 Phase Converter for CTs 1A Input to 200mA OutputCHK,CK1 (8751) AUAdaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20.

CHK 3 Phase Converter for CTs 5A Input to 200mA OutputCHK,CK5 (8752) AUAdaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.

CHK CR100 Clamp-on CTCHK,CR100 (8753) AU/MYJaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to measure neutral current. Accuracy Class 1.

CHK CR500 Clamp-on 500 CTCHK,CR500 (8754) AUJaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to measure neutral current. Accuracy Class 1.

Current Clamp Probe 0 to 1A RMSDRA-BMI,TR2501 ( 8765) AUSet of 4 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mm dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400. For current measurement through CT current Transformer. CT Ratio can be selected on the above mentioned models.

Dranetz TR2510 Current Clamp Probe 0 to 10A RMSDRA-BMI,TR2510 (8766) AUSet of 4 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mmØ. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400. For current measurement through CT current transformer. CT ratio can be selected on the above mentioned models.

Fluke 376 True-rms AC/DC Clamp Meter with iFlexFLU,376 (8770) AU/MY1,000A AC and DC current measurement with fixed jaw. 2500A AC current measurement with the 45cm iFlex flexible current probe. 1000V AC and DC voltage measurement. Voltage and current measurements are true rms. Includes ability to measure frequency, resistance and capacitance. Rated CAT IV 600V and CAT III 1000V.

Current Clamp Probes & Accessories cont’d.

Fluke i5sPQ3 AC Current Clamps, 5A (3 x i5S per set)

FLU,I5SPQ3 (8790) AUA pack of 3 pieces of the i5s 5A AC current clamps, specially configured to provide low current accuracy while taking measurements on secondary current

transformers. CAT III 600 V (For insulated conductors only). Suits the Fluke 435 and other instruments with BNC inputs.

Hioki AC/DC Clamp on Meter with Analog Output 20/200AHIO,3284 (8780) AUCan also measure volts, ranges 30V, 300V, 600V AC/DC. Frequency ranges 10Hz, 100Hz, 1,000Hz. Display LCD, counts max 2,500 current, 3,750 voltage, 1,250 frequency. Output voltage 1V for 2,000 count on FS for each current range, can select Rec rms output, response time about 250ms rise time, fall about 500ms. Select Mon for waveform output. 1V is produced for 1,000 count on FS frequency range. Output not available for voltage measurements. Supplied with signal output cord, 4mm to BNC convertor, carry case and AC adaptor. Note: Can be powered with internal 9V battery or AC adaptor. (AC adaptor not supplied.)

Hioki 3285 AC/DC Clamp-on Meter with Analog OutputHIO,3285 (8781) AURanges 200A/2kA AC/DC. Measure volts, ranges 30V, 300V & 600V AC/DC. Frequency ranges 10Hz, 100Hz & 1kHz. Display LCD, counts max 2,500 current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000 count fs for each current range, can select Rec RMS output, response time about 250ms rise time, fall about 500ms. Waveform output. 1V is produced for 1,000 count on FS frequency range. Output not available for voltage measurements. Supplied with signal output cord, 4mm to BNC convertor, carry case and AC adaptor. Powered with internal 9V battery or AC adaptor. (AC adaptor not supplied) adaptor.

Hioki 3290 Clamp-On AC/DC HiTesterHIO,3290 MYCurrent Measurement at DC and from 1Hz AC to 1,000Hz. Current Clamp Hioki 9693 Clamp-on AC/DC sensor ranges: 20A, 200A & 2,000A, jaw opening 55mm.

Hioki 9660 Clamp-on 100A AC CTHIO,9660CT100A (8783) AURated primary current 100A AC. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at 45 to 66Hz). 66Hz-5kHz ±1% or less. Max circuit voltage 300V RMS/insulated wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.

Hioki 9661 CCT-500A Clamp-On Sensors 500A, 500mVAC OutputHIO,9661 CCT-500A (8784) AU500A rated, 500mVAC FS output, core jaw 46mmØ. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meets all CE marking requirements. Basic specifications:

Rated input current 500A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz), amplitude: ±0.5% rdg ±0.2% FS FS (FS) is the 3196 range value, phase: ±0.5° or less, frequency characteristics 66Hz to 5kHz (±1% or less from accuracy), max allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire), core jaw Ø46mm, dimensions, mass 77mm W x 151mm H x 42mm D, 360g, cord length 3m.

Electrical Powerwww.techrentals.com.au

Page 34: normas quipment-solutions-guide

32

Current Clamp Probes & Accessories cont’d.

Universal Technic Clamp-On AC/DC Current Probe 4000/7500AUNI,P75-3C HYBRID-DP (8796) AURanges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and external power supply, 3V operation. Safety sockets 4mm. Clamp is suitable for use with any instrument with an input range of 2VAC or DC, and an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders, oscilloscopes, and power quality analysers.

Insulation Testers & Meggers to 20kVEA Technologies UltraTev Plus Partial Discharge Detector EAT,ULTRATEVPLUS (8410) AU

Multi-function Partial Discharge (PD) Instrument. It measures accurate PD activity using the UltraTEV detector and an ultrasonic detector. It gives you an objective measure of the level of activity. Will display PD severity level. The kit includes the Ultradish for measurement of overhead assets.

Fluke 1587 Insulation Multimeter FLU,1587 MYInsulation: measurement range: 0.01M to 2GΩ. Test Voltages: 500V, 1,000V, 50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to 1,000VAC/DC, current 0.01mA to 400mA AC/DC, resistance 0.1Ω to 50.0MΩ, capacitance 1nF to 9999μF, frequency 0.01Hz to 99.99kHz.

Fluke 1653 Electrical Installation Tester FLU,1653 MYTester verifies the safety of electrical installations, according to IEC 60364, HD 384 standards. Functions available: voltage and frequency measurement, insulation resistance testing, continuity testing, loop impedance, RCD tripping time, RCD tripping current, earth resistance and phase sequence.

Hioki 3455 High Voltage Insulation TesterHIO,3455HVIT-5kV (8411) AU/MYPI (Polarisation index) and DAR (Dielectric absorption ratio) function to check insulation quality and step voltage test to detect for signs of deterioration. Generates test voltages from 250V to 5kV in commonly used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set

to desired level by increments or decrements of 25V or 100V. Insulation diagnoses for automatic calculation and indication of PI and DAR, step voltage testing and temperature correction. Large memory stores up to 100 manual records and a logging function for 10 data (360 times). Stored data with date and time may be displayed on the LCD or down-loaded.

Kikusui TOS-5101 10kV AC/DC Hipot TesterKIK,TOS-5101 (8426) AUHipot testing up to 10kV in either DC or AC. Digital voltmeter and ammeter, digital timer. Window

comparator for more reliable pass/fail judgement. Automatic discharge of device under test in DC test mode. Equipped with Key Lock and Interlock functions for greater safety.

Current Clamp Probes & Accessories cont’d.

Hioki 9661-01 CCT-500A Clamp-on Sensors HIO,9661-01 CCT-500A (8785) AU500A rated, 500mVAC fs output, jaw 46mmØ. Rated input current 500A AC, rated output 0.5VAC, accuracy (at 45 to 66Hz). Amplitude ±0.5%rdg,

±0.2%FS, fs is the 3196 range value, phase ±0.5° or less, frequency characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire). Dimensions 77mm W x 151mm H x 42mm D, cord 3m. Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input.

Hioki Flexible Clamp-on Sensors 10Hz to 20kHz, 500/5,000AHIO,9667-FCT-5000A (8786) AU10Hz to 20kHz, 500/5,000A rated, 500mV AC FS output, 254mm diameter

maximum. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE marking requirements. Basic specifications: Rated input current 500A AC, 5,000A AC, rated output 0.5V AC, accuracy (at 45 to 66Hz). Amplitude: ±2% rdg ±1.2mV, FS (FS) is the 3196 range value, phase: ±1° or less, frequency characteristics 10Hz to 20kHz, maximum allowable input continuous 1,0000A rms (45 to 66Hz), maximum circuit voltage 1,000V AC rms (insulated wire), core jaw dia Ø254mm(10in). Dimensions: mass 254mmW x 86mmH x 30mmD, 140g. Sensor length: 910 mm. Suitable for the following Hioki Models: HIO,3196PQA, HIO,3197PQA, HIO,3169-20CLAMPONPT, HIO,2331-20RPMS, HIO,2331-20RPMS, HIO,8715-01, any data logger/scope which takes up to 1.7mV AC input.

Hioki 9669-CCT-1000A Clamp-on SensorsHIO,9669-CCT-1000A (8787) AUJaw 55mmØ, 80mm x 20mm busbar. Rated input current 1,000A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz) amplitude ±1% rdg, ±0.01% fs, fs

is the 3196 range value, phase ±1° or less, frequency characteristics 66Hz to 5kHz (±1%), max. Allowable input continuous 1,000A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire). Dimensions 99.5mm W x 188mm H x 42mm D, cord 3m. Suitable for Hioki models 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input.

Hioki 9694 Clamp-on CT 5AHIO,9694CT5A (8789) AURated primary current 5A AC. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45 to 66Hz), 66Hz to 5kHz ±1% or less. Max circuit voltage 300V RMS/insulated wire. Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m.

Universal Technic P75.3C DC/AC Amp ClampUNI,P75-3C (8795) AUMax current 7,500A DC & AC peak. Bandwidth 1kHz. Min range 1kA. Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size 122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V, life 100h. Output sockets 4mm. DC current gives DC output, AC current gives AC output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.

Electrical Power www.techrentals.com.au

Page 35: normas quipment-solutions-guide

33

Insulation Testers & Meggers to 20kV cont’d.

Megger MIT525 5KV Insulation Tester

MEG,MIT525 MYLight and compact 50V to 5,000V insulation resistance tester. Measures up to 10 Tera ohms. Diagnostic testing and maintenance of high voltage

electrical equipment. Various diagnostic tests such as Polarisation index(PI), Dielectric Absorption Ratio(DAR), Step Voltage(SV), Dieletectric discharge (DD) and ramp testing. Mains & battery powered.

Megger MIT1020 Diagnostic 10kV Insulation Resistance TesterMEG,MIT1020-10KV DIT (8423) AU

Backlit display, variable test voltage from 50V to 10,000V, Automatic IR, PI, DAR, SV and DD tests, measures to 35T, RS232 and USB download of results. IEEE 43-2000 recommends the use of 10kV for motor windings rated above 12kV. Protection rating of IP54. Mains or battery powered.

Megger MIT1025 10 kV DC Insulation Resistance Tester

MEG,MIT1025 (8427) AU10kV DC Insulation Resistance Tester. Measures to 20 Tohm at 10kV. Tests include PI, DAR, DD, SV and ramp test. Li-ion battery with rapid charge, mains

operation possible while battery is charging. Advanced memory with date/time stamp. Noise filter rejects up to 3 mA noise. PowerDB Lite asset management software supplied with unit for download of test data to a PC.

Megger S1-1052 High Current Insulation Resistance Tester 10kVMEG,S1-1052 10KV-DIT (8424) AU/MYHigh output current 5mA for fast charging of capacitive loads. Testing up to 10kV, mains or battery powered, digital/analogue backlit display,

variable test voltage from 50V to 10,000V, automatic IR, PI, DAR, SV and DD tests. Measures to 35TΩ. RS232 and USB download of results.

Megger S1-552 High Current Insulation Resistance Tester 5kVMEG,S1-552 5KVDIT (8425) AUHigh output current 5mA for fast charging of capacitive loads. Testing up to 5kV, mains or battery powered, digital/analogue backlit display, variable

test voltage from 50 to 5,000V, automatic IR, PI, DAR, SV and DD tests. Measures to 15TΩ. RS232 and USB download of results.

Oil, Hipot & VLF Testers above 20kVHipotronics 880PL-10MA-B 80kV DC Hipot TesterHIP,880PL (8491) AUCompact, portable unit (41kg) for DC field testing of cables, terminations, motors, generators and other electrical apparatus. 80kV 10mA output capability with multirange voltmeter

and ammeter. For operator safety the power supply and test object are automatically grounded when high voltage is turned off, and there is no exposed high voltage. Guard circuit for accurate leakage current measurement. Includes overload relay and surge limiting resistors in HV output.

Oil, Hipot & VLF Testers above 20kV cont’d. High Voltage Inc PFT503, 50kV AC Test SetHIV,PFT503 (8453) AUSingle, portable (34kg) unit suited for testing overhead apparatus, vacuum bottles and interrupters, switch gear, bus duct, motorized vacuum switches, reclosers, bushings, fuses and arrestors, linemans safety products, small transformers, electrical components and motors. This 3kVA model features capacitive load compensation enabling full load testing with a power draw of 1.5kVA while operating from a conventional line input. 60mA output current capability.

High Voltage Inc PFT-1003CMF 100kV AC Hipot Test Set

HIV,PFT1003 (8456) AUPortable (16kg control unit, 39kg HV tank) hipot tester, 100kV, 50Hz, rated 3kVA into capacitive loads. Features continuously adjustable output voltage, external safety interlock, zero start safety interlock,

self resetting over current protection, guard/ground return mode, HV on/off and main power push button ruggedized meters and with glass windows that eliminate static buildup.

HV Diagnostics HVA TD60 Portable TanDelta Measurement SystemHVD,HVA TD60 (8460) AUOptional Accessory for HVD,HVA60-DC/VLF and HVD,HVA90_DC-VLF. Tan Delta or Power Factor tester used to determine the power factor of cables, transformers, capacitors, rotating machines and other switchgear. This test allows the detection of insulation defects before they fail inservice.

HV Diagnostics HVA30 30kV-15mA DC/VLF High Voltage Insulation DielectricsTest Set

HVD,HVA30-DC/VLF (8461) AU/MYVLF and DC test capabilities combined in one unit (20kg). Suitable for testing cables (XLPE, PE, EPR, PILC etc), capacitors, switchgear, transformers, machines (IEEE 433), insulators and bushings. VLF

(0.1Hz to 0.02Hz), DC (±), cable fault conditioning (burning) and sheath/jacket testing modes all included. Fully automatic or manual cable test sequences complying with International Standards/Guides such as IEEE 400.2, VDE 0276 and CENELEC. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output wave form. Easy to use, ergonomic, menu guided, large backlit user interface. Large output load capability (up to 5uF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to a PC/Laptop.

HV Diagnostics HVA60 60kV VLF/DC Test SetHVD,HVA60-DC/VLF (8462) AU

VLF and DC test capabilities combined in one unit (60kg). Suitable for testing cables, capacitors, switchgear, transformers, machines, insulators and bushings. VLF (0.1Hz to 0.02Hz), DC (±), cable fault conditioning (burning) and sheath/jacket testing modes all included.

Fully automatic or manual cable test sequences. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output wave form. Large output load capability (up to 5μF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to a PC/Laptop. For a more comprehensive understanding of insulation condition perform tan delta testing at the same time with optional accessory HVD,HVA TD60.

Electrical Powerwww.techrentals.com.au

Page 36: normas quipment-solutions-guide

34

Oil, Hipot & VLF Testers above 20kV cont’d.

HV Diagnostics HVA90 90kV VLF/DC Test SetHVD,HVA90_DC-VLF (8463) AU

VLF and DC test capabilities combined in one unit (127 kg). Suitable for testing cables (XLPE, PE, EPR, PILC etc), capacitors, switchgear, transformers, machines (IEEE 433), insulators and bushings. VLF (0.1Hz to 0.01Hz), DC

(±), cable fault conditioning (burning) and sheath/jacket testing modes all included. Fully automatic or manual cable test sequences complying with International Standards/Guides such as IEEE 400.2, VDE 0276, CENELEC HD620 S1, NEN 3620, SANS 10198 and IEC 60060-3. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output wave form. Easy to use, ergonomic, menu guided, large backlit user interface. Large output load capability (up to 10uF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to a PC/Laptop. Optional Accessories: HVD,HVA TD60

Baur DAP75 Insulating Oil TesterBAU,DPA75 (8451) AUFully automatic insulation oil tester. Output voltage 0 to 75kV RMS. Selectable programmes to international standards. Integral printer. RS232 interface. One transit case on wheels. Total weight is 35kgs.

Megger OTS80PB Transformer Oil Tester Insulation Dielectrics Test SetMEG,OTS80PB (8450) AUTest voltage 80kV max at 61.8Hz. Fully automatic operation. Rechargeable batteries. RS232C interface.

Phenix BK130 130kVAC Hipot Aerial Lift Test SetPHE,BK130 (8480) AUTests elevating boom as well as the work platform and linings to ANSI A92.2 draft standard. Can also he used in many other Hipot applications that require the sort of voltage and current this instrument is capable of. Can supply 0 to 130kVAC @ 50mA and 0 to 35kVAC at 171mA. The whole system is built into a trolley cart for ease of use. Measurement accuracy 1% FS for 10 to 100% of range.

Transformer TestersBiddle 550005 Turns Ratio Test SetBID,550005 (8550) AUSingle phase (can be used on 3ph individual phase windings). Turns ratio 0.001 to 129.999. Exciting current 0 to 1A. Accuracy 0.1%. Hand cranked operation.

Megger CAL 300 IDAX Calibration Box

MEG,CAL300 (8551) AUExclusively used for calibration of Megger IDAX Insulation Diagnostic Analysers.

Megger IDAX 300 Insulation Diagnostic Analyser

MEG,IDAX300 (8552) AUProvides an accurate and reliable condition assessment of insulation in transformers, bushings, generators and cables. It utilises Dielectric Frequency Response in combination with analysis in software to determine the percent of moisture in paper insulation, oil conductivity and an individually corrected tan delta value at 20°C reference temperature.

Transformer TestersMegger MTO330 Automated Six Winding Transformer OhmmeterMEG,MTO330 (8553) AUDelivers full eight-terminal/six-winding resistance measurement capability. It is designed to save time by testing all six windings without having

to disconnect and reconnect leads. Also, the simultaneous winding magnetization method gives fast and reliable measurements even on large transformers with delta configuration on the low voltage side. The leads are interchangeable with the Megger TTR320 three-phase turns ratio instrument which eliminates additional connecting time for turns ratio measurements (However, TTR320 leads must NOT be used with the MTO330. The leads have a higher current rating). Includes an on-board computer with QWERTYkeyboard, USB and ethernet.

Megger TTR320 3-Phase Transformer Turns Ratio Test SetMEG,TTR320-47 (8554) AUAccurately measures ratio, phase deviation and exciting current on 3-phase transformers in the

presence of high noise. Can test phase-shifted and tilted transformers, in accordance with IEC61378, when testing via PowerDB. Test results can be stored and downloaded at a later time. Handles ratios up to 45,000:1 with 0.3% accuracy, 0.1% up to 2,000:1. Compatible with the Megger MTO330 transformer ohmmeter leads which eliminates additional connecting time for turns ratio measurements (However, TTR320 leads must NOT be used with the MTO330. The MTO330 leads have a higher current rating). Includes an on-board computer with QWERTY keyboard, RS232 and ethernet.

Omicron CT Analyser Current Transformer AnalyserOMI,CTANALYZER (8555) AUPortable (8 kg) and automated unit for testing protection and metering CTs on-site. CTs can be verified up to the 0.1 accuracy class. The included CT SB2 switchbox allows automated testing of CTs with up to six taps. Remanence can be measured and cores can be demagnetised.

Omicron FRA Frequency Response AnalyserOMI,FRA (8556) AUUses swept frequency response analysis to detect mechanical and electrical changes of the core and winding assembly of power transformers. By finding winding or core defects after faults, mechanical shocks or transportation, it offers a valuable opportunity to improve the reliability of transformers,

to reduce maintenance costs and to avoid expensive, unexpected outages. Laptop included, preloaded with the FRAnalyzer software.

Circuit Breaker TestersMegger TM1760 Circuit Breaker Analyser System

MEG,TM1760 (4670) AUAdvanced Circuit Breaker Analyzer with built-in PC and utilising DualGround method for safer testing. Galvanically isolated inputs and outputs makes it possible to perform all relevant measurements in

one test, eliminating the need for new setup and re-connections. Includes 3 static & dynamic resistance modules with up to 220A test current, a 3-channel dynamic capacitance module and a full set of required cables.

Electrical Power www.techrentals.com.au

Page 37: normas quipment-solutions-guide

35

Current InjectorsMulti-Amp MS-2 High Current Test SetMUL,MS-2 (4600) AUDesigned to test overload relays, circuit breakers and earth fault trip devices. Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A, 24V/25A, 6V/120A & 3V/240A. Short term over

current of several times the rated current ranges is possible. Digital current meter has read and hold facilities for short duration currents. Digital timer measures elapsed time between energisation and the test device operating.

Omicron CPC 100 Multi-functional Primary Test SystemOMI,CPC100PTS (4620) AU

Portable (29 kg) primary test system suited for testing of current transformers, voltage transformers, power transformers, power lines, HV cables, grounding systems, switchgear and circuit breakers, protection relays and more. Tests to 800A (extended to 2000A with CP CB2)

over frequency range 15Hz to 400Hz, or to 400A DC. Laptop included, preloaded with CPC 100 Toolset. Optional accessories: OMI,CPCU1 (with or without OMI,CPSTEP) OMI,CPSB1 OMI,CP-TD1 OMI,CPCB2.

Omicron CP CB2 Current BoosterOMI,CPCB2 (4605)Combined with the CPC 100, the CP CB2 boosts the output current of a CPC 100 from 800A to 2000A.

Omicron CP CU1 Multi-Purpose Coupling Unit for CPC 100OMI,CPCU1 (4623) AUCombined with the CPC 100, the CP CU1 is a measurement system for line impedances &

k-factors of overhead lines or power cables, mutual coupling of parallel lines, ground impedances of large substations and coupling of power lines into signal cables. This test system overcomes the problem of power system frequency interference that has previously made it necessary to use extremely large, high-power equipment to carry out these measurements.

OMICRON Step & Touch Voltage Accessory Set

OMI,CPSTEP (4624) AUCombined with the CPC 100 and CP CU1, this kit is a measurement system for Step & Touch voltages. The battery powered FFT Voltmeter (CP AL1) operates with short leads and requires no connections back to the CPC 100.

Omicron CPSB1 Switch BoxOMI,CPSB1 (4621) AUSwitch Box to allow fully automated 3 phase transformer testing, accessory for the CPC100.

Omicron CP TD1 Capacitance and Tan Delta Add-onOMI,CP-TD1 (4622) AUCombined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laboratory precision. This allows the insulation condition of transformers, generators and other parts of high-voltage systems to be tested according to IEEE 62 (C57.152), IEC 60076-1 and -3, as well as the CIGRE “Guide for Transformer Maintenance”. As recommended in the CIGRE Guide, testing is performed at variable frequencies

to better diagnose signs of ageing in insulation. The portable test system (max. 29 kg per component) can also generate output voltages of up to 12kV. Trolley included.

Current Injectors cont’d.SMC PTE-100-C Secondary Current Test Set SMC,PTE-100-C (4601) AUAC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A & 10V/100A. Additional outputs AC voltage 0 to 220V at 1A (4A 1min), DC voltage 0 to 350V at 0.7A (2.8A

1min), DC voltage 0 to 250V at 0.25A, fixed 110V AC at 0.3A. Timer 1ms to 99,999s. Additional functions include measurement of the phase angle between the voltage and the current output tap selected, and the measurement of the impedance of the load connected in the current output taps.

T&R 200A-3PH/ED Current injection testerT&R,200A3PHEDIT (4602) AU0 to 200A/phase output capacity. Power supply 4 wire 5A/phase 3ph 240/415V. Typically 10A 5 pin 3 phase socket outlet.

T&R CIT/LU2000 Primary Current Injection Test SetT&R,CIT (4603) AUComprises control unit and 2kA loading unit (LU). Control unit includes timer, current and voltage meters, and variable output transformer. External loading unit output 0 to 2kA, duty 5min on 15min off at 6VAC, continuous 0 to 1kA at 3VAC. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets each 3m long. Control unit connects to LU with supplied interface cable.

T&R PCU1-SP with CT Ratio/Polarity and NLU5000A Loading UnitT&R,PCU1-SP NLU5000A (4604) AUMedium powered primary current injection system. Features 5kA maximum output current (higher overload current for 2s). Multi-function digital timing system. Digital true RMS memory ammeter. Solid state switching.

2,000A and 5,000A load units. Three range outputs on loading units. Rugged, compact design. Secondary injection up to 100A. Direct reading CT ratio and polarity. May be configured to either give a maximum current of 5,000A on the 2.3V range, 2,500A on the 4.6V range or 1,250A on the 9.2V range.

Protection Relay Testing SystemsOmicron CMA 156 Six Phase Current Amplifier (6 x 25A) OMI,CMA156-6PCA (4655) AUCan be used in combination with any CMC test set. The outputs

are galvanically separated from the inputs as well as from ground and are used independently or in addition to those of the CMC test sets. The six independent current channels are arranged in two isolated groups (A, B). The outputs can be connected in parallel or in series. The connection to a CMC test set is made by a control cable at the back of the units. Used for tests requiring more current channels than provided by the CMC test sets.

Omicron CMC256-6 Universal Relay Test SetOMI,CMC256-6 (4660) AUProtection relay test set and universal calibrator (energy meters,

measuring transducers, power quality measurement devices, phasor measurement units etc) with six current sources (6 x 12.5A, 3 x 25A or 1 x 75A), four voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional binary inputs (dry/wet) and Generator Combination Cable for wiring convenience. The six current and four voltage output channels are continuously and independently adjustable in amplitude, phase and frequency. All outputs overload and short-circuit proof. LLO-2 option not included. Laptop included, preloaded with Test Universe software (Universal). Optional accessories: OMI,CMA156-6PCA OMI,CMGPS.

Electrical Powerwww.techrentals.com.au

Page 38: normas quipment-solutions-guide

36

Protection Relay Testing Systems cont’d.

Omicron CMC 256plus Universal Relay Test Set OMI,CMC256PLUS (4661) AU

Improved accuracy specifications. Protection relay test set and universal

calibrator (energy meters of class 0.2, measuring transducers, power quality measurement devices, phasor measurement units) with 6 current sources (6 x 12.5A, 3 x 25A or 1 x 75A), 4 voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional binary inputs (dry/wet) and Generator Combination Cable for wiring convenience. The 6 current and 4 voltage output channels are continuously and independently adjustable in amplitude, phase and frequency. All outputs overload and short-circuit proof. LLO-2 option not included. Laptop included, preloaded with Test Universe software (Universal). Optional accessories: OMI,CMA156-6PCA

Omicron CMC 356 Advanced Protection Relay Test SetOMI,CMC356 (4656) AU

Protection relay test set with 6 current sources (6 x 32A/430VA, 3 x 64A/860VA or 1 x

128A/1000VA), 4 voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional binary inputs (dry/wet) and Generator Combination Cable for wiring convenience. The 6 current and 4 voltage output channels are continuously and independently adjustable in amplitude, phase and frequency. All outputs overload and short-circuit proof. Laptop included, preloaded with Test Universe software (Advanced Protection + Transducer). Optional accessories: OMI,CMA156-6PCA OMI,C-PROBE1 OMI,CMGPS

Omicron CMC 356 Advanced Protection Relay Test Set +61850OMI,CMC356_61850 (4657) AU

Protection relay test set with 6 current sources (6 x 32A/430VA, 3 x 64A/860VA or 1 x

128A/1000VA), 4 voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional binary inputs (dry/wet) and Generator Combination Cable for wiring convenience. The 6 current and 4 voltage output channels are continuously and independently adjustable in amplitude, phase and frequency. All outputs overload and short-circuit proof. Includes IEC61850 software package (GOOSE, Sampled Values, IEDScout, SVScout). ELT-1 and LLO-2 options not included. Laptop included, preloaded with Test Universe software (Advanced Protection + Transducer) and IEC61850 package. Optional accessories: OMI,CMA156-6PCA OMI,C-PROBE1 OMI,CMGPS

Omicron CMGPS Syncronisation Control UnitOMI,CMGPS (4662) AUOptional accessory for use with any OMICRON CMC test set. Included are two GPS unit which provide a start signal pulse based on the GPS clock time base. Software is integrated in the testing modules (State Sequencer). Can also be used as a stand-alone application.

Omicron C-Probe-1 Clamp-on CT AC/DCOMI,C-PROBE1 (4664) AUOptional accessory for OMI,CMC356 & OMI,CMC356_61850. An active AC and DC current probe with voltage output. Recommended accessory for measuring currents with the CMC356. It has 10A and 80A measuring ranges, frequency range DC to 10kHz. Accuracy error < 2% for currents up to 40A and frequencies up to 1kHz. Phase error <0.50 @ 50/60Hz. Length 230mm. Output: 0-10A range 100mV/A, 0-80A range 10mV/A.

Megger (Programma) Sverker760 Relay Test Set PRO,SVERKER760 (4672) AURelay test set for 1ph protective relay equipment. Three phase relays can be tested 1 phase at a time or by synchronising more than one unit. Current ranges to 100A with full load current to 250A. AC outputs to 250V & DC outputs to 300V. In-built capacitor and resistors for current output phase shifting (3,600). In-built timer, ammeter, and voltmeter. Measures phase angle, PF, and impedance.RS232 communications and control interface.

AC Sources/Inverters/GeneratorsChroma 61501 Programmable AC Power SourceCHR,61501 PAC-PS (6400) AUPower: 500VA. Voltage: 0-150V/0 to 300V/AUTO. Compact size and weight attributable to advance PWM technology. AC, DC, AC+DC output mode. Programmable output impedance for IEC 61000-3-3. IEC 61000-4-11 voltage dips and variation simulation. Harmonics, inter-harmonics waveform synthesizer for IEC 61000-4-13 testing. Power line disturbance simulation capability. Programmable voltage, current limit. Comprehensive measurement capability, including current harmonics. High output current crest factor, ideal for inrush current testing. Turn on, turn off phase angle control. TTL signal which indicates output transient. Software for IEC regulation test. Analog programmable interface. Optional GPIB and RS232 interface.

Power Transformers & VariacsDimmer Dot 0-270V AC, 17A VariacDIM,D201P (8230) AU

Single phase variac. 240 V AC input, 0-270V AC output at 17A. Input and output connections must be wired up under a protective cover.

Variac 6500-3 3ph 6.5kVA TransformerVAR,6500-3 (8228) AUVariac 3ph 6.5kVA. 0 to 470VAC output for 415VAC input, max current 8A/ph.

Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23-28AVAR,D-283-OB (8229) AUManual operated air cooled; Input 400/415V, 50Hz. Output 0 to 415/470V. 23 to 28A. Total Weight 95kgs.

Battery Management SystemsHioki Battery HiTesterHIO,3551BATTERYTEST (8275) AUTakes on-the-spot measurements of the internal resistance, voltage and temperature of lead-acid batteries, principally for UPS and similar applications, without needing to shut off the battery. Instantaneous

results, on a three-rank scale of Pass, Warning, or Fail, using a composite decision based on the internal resistance and the voltage. Resolution of 1μΩ, necessary for high capacity batteries (of at least 500Ah). Includes Hioki 9460 clip type temperature leads.

Megger Torkel 840 Battery Load Unit PRO,TORKEL-840 (8276) AUPortable (22 kg, 38 kg with accessories and transport case) battery discharge load unit. Works with 12V to 250V battery systems and can discharge at up to 110A (15kW maximum power). Can be programmed for constant current, constant power, constant resistance or user defined load profiles. The included DC current clamp allows on-load testing. Tests can be PC controlled and results reviewed using the included TORKEL Win software. The load current can be extended with the optional accessory PRO,TXL870 extra load unit.

Megger (Programma) TXL870 Extra Load Unit

PRO,TXL870 (8277) AUOptional accessory for the PRO,TORKEL-840 battery load unit. Adds up to an extra 112A load capacity to a discharge test (15.8kW maximum). Operates as a slave in combination with a PRO,TORKEL-840 battery load unit.

Electrical Power www.techrentals.com.au

Page 39: normas quipment-solutions-guide

37

Save your time and reduce your costs by using our data management services. Learning to operate unfamiliar equipment costs you time and can lead to fundamental errors in data capture processing. There is a better solution - our setup and download service.

Our technical staff are equipped and trained to deliver you the downloaded data in a range of suitable output formats including USB drive, CD-ROM, printout, chart and DVD according to your need and the product’s functionality.

When you nominate your output preferences and appropriate technical information, the rest is taken care of. The completed fi les or printouts will be forwarded to you quickly or may be collected at an arranged time.

The equipment marked with ‘S’ symbol is available to rent with this service. Fees vary depending on the complexity of operation and the level of detail involved.

Data management services are available for many products. Below are some examples of what you can expect.

SEWARD ProTag Optima 300 Testing & Tagging System (SEW,PT-300)

Setup:• Load logo fi le in printer• Load test settings

Results Downloaded:• Provide database in PATGuard format• Provide CD with PATViewer software including database for end customer

FLUKE DTX1800 Cable Analyser(FLU,DTX1800)

Setup:• Company name• Site• Tester• Setup of certifi cation test limit• Cable type

Results Downloaded:• Raw Fluke Linkware fi les• Linkware software• PDF report of results

FLUKE Ti25 Thermal Camera (FLU,TI25)

Results Downloaded:• Raw image fi les• Relevant editing software• Adjust isotherm and emissivity• Standard report of images

CHK PM30/ PM30PLUS - 3CTs Power Quality Analyser [Note: Max current is 1000A for PM30]CHK PM40/ PM45 - 4CTs Power Quality Analyser (CHK,PM30)

Setup:• 3P4W(star) or 3P3W(delta)• Max. Current (<1000A or <3000A)• 3P Current only or 3p and Neutral• Log Period and Log Interval• Log Profi ling (V,I,PF,kWh,THD)• Event Capture (Sag,Swell,Transient)• Start Log Next Power up

Results Downloaded:• Raw Data• PowerView Software• PDF report of V & I Trend Graph• Total kWh Calculation• Exported Data as CSV or Excel fi les

FOURIER DAQPRO Hand-Held Data Logger (FOU,DAQPRO-2)

Setup:• How many channels to be measured (Out of 8 channels)• Each channels measurement. eg Voltage - Current etc• Channel scaling• Period of logging to determine logging interval• Logging Interval

Results Downloaded:• Data results • DAQPRO viewing software and editing

SETUP AND DOWNLOADwww.techrentals.com.au

Page 40: normas quipment-solutions-guide

38

Temperature Meters/IR ThermometersInfrared Thermal Imaging CamerasEndoscopes Borescopes Visual InspectionHigh Speed Video Inspection CamerasTachometers/StroboscopesLaser Rotational Shaft AlignmentIndustrial Process CalibratorsWet & Dry Block & CalibratorsStrip Chart RecordersHigh Speed Waveform RecordersData LoggersPressure & Humidity TransducersPressure Vacuum Gauges/RecordersFlow Meters for Liquids & GasesCombustion, Flue & Industrial Gas AnalysersEnvironmental Test Chambers/OvensUltrasonic Baths

Temperature Meters/IR Thermometers

Fluke 52-2 Digital ThermometerFLU,52-2 MYDual input thermocouple thermometer supplied with two K type thermocouples for differential measurements. Sampling rate of 1Hz (1 probe) or 1.7Hz (2 probes). Will continuously record max and min measurements. It also can take K,J,T and E type Thermocouple inputs. Temperature range: K type: -200°C to 1,372°C.

Fluke 54-2B 2 Channel Data Logging Temperature Meter with FlukeViewFLU,54-2B-FVF (4507) AUDual input digital thermometer with data logging. Will take most TC inputs. Accuracy ±0.05% of reading +0.3ºC. 500 point logging with date & time stamp. Also records min, max or avg. Logged data can be reviewed on meter or downloaded to PC using software included. Supplied with 2 x 400mm K type thermocouple leads.

Fluke 80TK Thermocouple ModuleFLU,80TK (4531) AUUse with DVM’s and recorders. Accepts K thermocouples. Temperature range -50 to 1,000ºC. Output 1mV/ºC. Type 80KP-1 probe included.

General Industrial & Process Management www.techrentals.com.au

Now all the thermal imagers in the Ex, Exx and T-Series ranges come standard with FLIR’s patented MSX® technology for extremely sharp, detail-rich imaging.Across the entire FLIR range, innovative features are standard including built-in visual camera, Wi-Fi and Bluetooth. Connect to smart phone or tablet via Wi-Fi for processing and sharing results as well as for remote control.With prices starting from as little as $1639 inc GST, FLIR’s Ex-Series range sets a new benchmark in feature-packed thermal imaging technology at very affordable prices. And now FLIR’s Exx-Series offers even more with the addition of MSX® and auto orientation.Designed for entry-level users who want to get the most out of their thermal imaging camera, the FLIR Ex and Exx

ranges are perfect for electrical and mechanical inspections, HVAC, plumbing and building diagnostics. The T-Series remains FLIR’s most flexible and professional grade handheld thermal camera in the range and leads the field in image quality, ergonomics and user-friendly features like image sketch directly onto LCD touchscreen, voice annotation and tilt lens.Local Service NetworkWho else would you trust to calibrate and service your FLIR camera but FLIR Australia? As a factory certified service centre it makes perfect sense. As most FLIR thermal cameras are eligible for FLIR’s industry leading 2-10 product and detector warranties* buying a FLIR is an easy decision.

Experience the world of thermal imaging.The result? Faster detection. Detailed analyses. Faster conclusions.

FLIR Systems Pty Ltd.VIC: 03 9550 2800 NSW: 02 8853 7870 WA: 08 6263 4438 Tel AU: 1300 729 987 NZ: 0800 785 492 Email: [email protected]

www.flir.com

ISO

No

. FLI

R20

850

Dis

clai

mer

: Im

ages

fo

r ill

ust

rati

ve p

urp

ose

s o

nly

. Sp

ecifi

cati

on

s su

bje

ct t

o ch

ang

e w

ith

ou

t no

tice

.

Ex-Series

Exx-Series

T-Series

Page 41: normas quipment-solutions-guide

Temperature Meters/IR Thermometers cont’d.

Fluke 576 Photographic Temperature Infrared Thermometer Built in CameraFLU,576 (4519) AU/MYRange -30 to 900ºC. Minimum measurement 19mmØ, laser class II, 3 point spot. Includes adjustable emissivity from 0.1 to 1 by 0.01. Target size 1/60 of distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data output USB or 1mV/ºC, Windows software and cable included. Accuracy ±0.75% of reading or ±1ºC whichever is greater. Response time 250ms. Display resolution 0.1ºC. Continuous measure mode. Digital camera and flash built in.

Fluke 1523 NATA Precision Handheld ThermometerFLU,1523-NATA (4514)Precision, portable, electronic thermometer with trending and 25 memory positions for NATA-traceable calibration and high accuracy. Includes 5616 probe 298mm x 6.35mm 100Ω platinum resistance thermometer probe (PRT) -200 to 420°C, stability ±10mK, accuracy ±0.012°C at -200°C, ±0.011°C at 0°C, ±0.028°C at 420°C.

Temperature Meters/IR Thermometers cont’d.

Testo 845 IR Thermometer with Humidity Probe and T/C ProbeTES,845 (4527) AUTemperature measurement -35 to 950°C. Relative humidity probe 0 to 100%RH. Fast-action surface probe with sprung thermocouple strip, also for uneven surfaces. Switchable optical resolution: far field: 75:1 (16mm at a distance of 1200mm). Close focus: 1mm at a distance of 70mm. Adjustable emissivity from 0.1 to 1, max, min, displayed on backlit LCD. Continuous measure mode. Data output software and cable included. Accuracy ±0.75% of reading 100 to 950°C. Display resolution 0.1°C.

Infrared Thermal Imaging CamerasFlir E60 Infrared Thermal Image CameraFLI,E60 (4550) AU/MY-20°C to 650˚C, IR resolution 320x240, 60Hz,

visual image 3mpix, built in LED lamps, laser locator, scalable picture in picture. MPEG4 recording, touch screen, composite video out, Wi-Fi, and USB. Infrared camera applications include electrical distribution, mechanical (belts, rollers, couplings, gaskets/seals,

compressors etc), product development, HVAC/R, automotive. Bluetooth support for voice annotations and selected Extech equipment. PC software provided. iPhone/iPad app available.

General Industrial & Process Managementwww.techrentals.com.au

New items are being added to the inventoryconstantly, so if you do not see what you arelooking for please call 1800 632 652.

Page 42: normas quipment-solutions-guide

40

Infrared Thermal Imaging Cameras cont’d.

Fluke Ti32 Infrared Thermal Image CameraFLU,TI32 (4559) AU/MY

-20°C to 600°C, resolution 320x240. Infrared camera applications include inside and outside electrical distribution, motors, pumps, generators, mechanical (belts, rollers, couplings, gaskets/seals, compressors etc). Process industry tanks/vessels, pipes, valves, traps, reactors, and process insulation, HVAC/R.

Fluke Ti32 Infrared Thermal Image CameraFLU,TI32_WIDE-ANGLE MYField swappable, wide angle thermal lens allows the user to have a wider field of view for working in tight spaces, small rooms, etc. Field-of-View (FOV) is 46° x 34°. For use with the Ti32 and TiR32.

Fluke Ti32 Infrared Thermal Image Camera with Telephoto LensFLU,TIR32 TELEPHOTO (4560) AU

Iinfrared thermal imaging camera. -20 to 600°C, resolution 320x240. Applications include inside and outside electrical distribution and transmission infrastructure, motors, pumps, generators, mechanical (belts, rollers, couplings, gaskets/seals, compressors etc). Process industry; tanks/vessels, pipes, valves, traps, reactors, HVAC/R. Includes detachable telephoto lens, field-of-View (FOV) 11.5° x 8.7°.

Infrared Thermal Imaging Cameras cont’d.

Flir T390 Infrared Thermal Image Camera

FLI,T390 (4556) AUInfrared thermal imaging camera. -20°C to 1,200°C. MPEG 4 video recording and composite out, is suitable for almost any application such as electrical

surveys, building diagnostics and mechanical inspections. With a 3.5 inch touch screen, Fusion functionality, auto and manual focus, target illuminator, laser locator and voice text annotation. 50Hz refresh rate, IR Resolution 320 x 240, visible light camera 3.1 MP.

Fluke Ti25 Infrared Thermal Image CameraFLU,TI25 (4567) AU/MY

Temperature range -20°C to 350°C, IR resolution 320x240, 60Hz, visual image 3mpix, built in L, accuracy ±2°C or 2% (whichever is greater). Manual

focus. SD memory card (2GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60s voice annotations or 3,000 basic (.bmp) IR images). Infrared camera export file formats JPEG, BMP, GIF, P, TIFF, WMF, EXIF, and EMF. IP54 rating.

General Industrial & Process Management www.techrentals.com.au

Uptime or Downtime. YOUR RESULTS MATTER.Only the NEW infrared cameras from Fluke have LaserSharpTM Auto Focus for consistently in-focus images.

EVERY. SINGLE. TIME.

4040404040404004040404040404444404040404004

UUUUUpppptttttiiiiimmmmmeeee oooorrrrr DDDDDooooooowwwwwwwwnnnnnnnnnnttttttttiiiiiiiiiiimmmmmmmmmmmeeeeeeeeeeeeeee.....

YYYYOOOOOOOUUUUUURRRRRRR RRRRRRREEEEEEEESSSSSSSSSSUUUUUUUUUUUUUUUULLLLLLLLLLLLLLLTTTTTTTTTTTTTTTTTTTSSSSSSSSSSSSSSS

OnOnlylyyy ttthehehehe NNNNNNEWEWEWEWEWEWWWWW iiiiiiiiinfnfnfnfnfnfnffrararaaaraarerererererer d d d dddddd cacacacacacacacaac mmememememeememem rarararaaaraarrrr s sss frfromm FFFlululuukekekeke hhhhhhhhhavavavavavaaa e e eee LaLaLaLaLaaasesesesesess rSrSrSrSrShahahahahahaarprprprprprpr TMTMTTMTMTM

Autoo FFFococusususus ffffororor cccccoononononnsisisiisisiistststststs enenene tltlt y yy yyin-foccoo usuus iimamamamaggegegeeeeees.s.s.s.s.s.s.s

EEEVVVEERRYY.. SSSSIIIIINNNNNNNGGGGGGGGGLLLLLLLLLEEEEEEEEEE...... TTTTTTTTTTTTTTTIIIIIIIIIIIIIMMMMMMMMMMMMMMMMEEEEEEEEEE.......

Page 43: normas quipment-solutions-guide

41

Endoscopes BorescopesVisual Inspection See also Pipeline & Cavity Inspection on page 61-62

Fibrescope MTFS15-1000 1.5mm x 1m EndoscopeFIB,MTFS15-1000 (5168) AUWorking length 1,000mm x 1.5mmØ. Includes light source. Operating temperature -20 to 60ºC at atmospheric pressure.

Moritex PalmScope Video Capture Device for JPEG & Movie Clip Recorder Inspection MOR,PALMSCOPE (5186) AUDigital Video Recorder, image capture and storage. Used in conjunction with an endoscope, borescope

or videoscope the PalmScope is an alternative to a VCR for onsite inspection applications. Unit records, store video sequences and full frame resolution jpeg images on supplied 512Mb Compact Flash Card. View images on built in 6.4” TFT LCD screen. Stores jpeg still images and or mjpeg movie clips. Signal input video NTSC or PAL, auto-selecting.

Olympus IPLEX-LT 7.5 Portable Industrial Videoscope

OLY,IPLEX-LT 7.5 MYLightweight, 2.7kg out of transit case. 8mm

diameter, 7.5m length tungsten insertion tube with LED illumination and comes with 6.5 inch TFT display. 4 way, 140° articulation. Still and movie recording to USB flash. IP55 compliant. Applications include inspection of, heat exchangers, turbines, gearboxes, automotive parts and aircraft.

Olympus IPLEX LT 3.5m Portable Industrial Videoscope

OLY,IPLEX-LT 3.5 (5198) AULightweight, 2.7kg out of transit case. 8.5mm diameter, 3.5m length tungsten insertion tube. 4 way, 140° articulation. Still and movie recording to USB flash. IP55 compliant. Applications include inspection of, heat exchangers, turbines, gearboxes, automotive parts and aircraft.

Olympus IPLEX-LX Portable Industrial VideoscopeOLY,IPLEX-LX MYBattery powered industrial videoscope, lightweight 2.7kg out of transit case. 4mmØ,

3.5m length tungsten insertion tube, articulation 4 way up/down/left/right 120°. Field of view 120°, depth of field 18 to 1,000mm, illumination method LED. Brightness adjustment and digital zoom, built in 6.5 inch TFT colour display, record JPEG images and video to USB flash device. RCA composite video output. Battery or AC powered.

Olympus IPLEX- MX II Portable Industrial Videoscope OLY,IPLEX-MXII (5179) AUBattery powered industrial vidoscope, lightweight, just 2.5kg out of transit case. 6mmØ, 3m length tungsten insertion tube,

articulation 4 way UP/DOWN/LEFT/RIGHT 120º. Field of view 120º, depth of field 18 to 1000mm, illumination method LED. Brightness adjustment and digital zoom, built in 6.5” TFT colour display, record JPEG images to USB flash device. RCA composite video output. Battery or AC powered.

Endoscopes Borescopes Visual Inspection cont’d.

RF Systems VJ-ADV Articulating 3.9mm Video BorescopeRFS,VJ-ADV (5184) AUVideo borescope is 3.9mm in diameter and 1.5 meters long with a flexible stainless steel braided insertion tube with adjustable brightness and 90 degree 4 way articulation. Images and video can be captured and saved to a micro SD card. Applications include turbine inspection, heat exchangers,

gearboxes in automotive or electrical power generation, chemical, oil and gas vessel inspection.

High Speed Video Inspection Cameras

Olympus High Speed CameraOLY,ISPEEDLT (5217) AU

High speed video camera including stand and lighting accessories. 800x600 color resolution at 1,000fps. Maximum frame rate 2,000fps. 2.24sec recording time color camera. 4 x lens kit supplied. Maximum shutter speed 5us.

Tachometers/StroboscopesHioki 3404 Optical/Contact TachometerHIO,3404 (5211) AU/MYAutoranging 4 digit display. Ranges in RPM mode 30 to 99.9, 1,000 to 9,999 & 1,000 to 9,999 x 10. Ranges in RPS mode 0.5 to 99.99, 100 to 999.9 & 1,000 to 1,600. Analogue output 1mV/10RPM or 1mV/100RPM, accuracy 4%. Tripod mounting. Internal battery or external AC operation. Contact adaptor included with cone and peripheral ring.

Monarch Palmstrobe Compact Size Portable StroboscopeMON,PALMSTROBE (5208) AUCompact size portable stroboscope, flash rate from 100 to 12,500FPM, 6 digit alphanumeric backlit LCD. Tachometer range 5 to 250,000RPM (only with external sensor connected, not included). External sensor input TTL only. Supplied with 2 x removable rechargeable battery packs, charger and transit case.

Monarch Phaser Strobe Battery OperatedMON,PHASER (5206) AUPhaser-stroboscope includes optical and magnetic pickup. Operates from internal re-chargable batteries or mains. Auto step mode provides slow motion appearance for high speed repetitive events. Stores and recalls last 3 full settings in memory. Specifications: 30 to 30,000 fpm or 0.5-533.33 fps. Accuracy ±0.01%. Flash rate external triggering: 30 to 9,999.9 fpm, 0.5 to 533.33 fps, 10,000 to 32,500 fpm. Phase delay facility.

Monarch PLT200-KIT Digital Contact/Non Contact TachoMON,PLT200-KIT (5214) AUHand held digital contact/non-contact tacho kit. Ranges optical/non-contact 5 to 200,000 RPM, contact 0.5 to 20,000 RPM. Display 5 digits, 5 alpha numeric LCD. Non contact operating range 90cm, tripod mounting. Direct contact tips and contact wheel

supplied. Programmable for IPM, FT/M, YPM, cm/M, m/M, RPM, RPS, RPH and Totaliser up to 200,000. Output TTL pulse.

General Industrial & Process Managementwww.techrentals.com.au

Follow TechRentals on LinkedInhttp://linkedin.com/company/techrentals

Page 44: normas quipment-solutions-guide

42

Laser Rotational Shaft AlignmentFixturlaser Dirigo Laser Bases Shaft Alignment SystemFIX,DIRIGO (4940) AUMeasurement resolution to 0.01mm Shaft diameter range 40 to 150mm using an extension chain 150 to 500mm. Maximum distance between measurement units 0.85m. Very simple to use and operate as shims are applied the alignment can be monitored in real time. 20h of operation from alkaline batteries.

Fixturlaser PAT Pulley Alignment SystemFIX,PAT (4941) AULaser based alignment system for pulley systems. Measurement accuracy 0.5mm (0.2º). 20hrs of operation on AAA batteries. Mechanically self centres on pulley, will operate successfully even on worn pulley systems.

MCE Pipe Laying Laser Alignment SystemMCE,LS140G (4942) AUPipe laying laser alignment system. Simple system for setting pipe grades. Applications include sanitary and storm sewers, tunnelling and Pipe Jacking. It includes a remote to adjust the grade and left right alignment. Kit includes

target, remote and legs for different pipe sizes etc. This system uses the Green laser wich is considerably brighter than a red laser.

Pruftechnik Rotalign Pro Laser Shaft Alignment ExPRU,ROT-PROEX (4943) AU

Intrinsically safe laser based rotating shaft alignment system. Maximum separation between emitter and receiver 10m. Aligns horizontal and vertical machines, aligns coupled and uncoupled shafts equally well.

Pruftechnik Rotalign Ultra Laser Shaft AlignmentPRU,ROT-ULTRA (4945) AU

Laser based rotating shaft alignment system. Maximum separation between emitter and receiver 10m. Aligns horizontal and vertical

machines, aligns coupled and uncoupled shafts equally well. Ultra modern computer design, backlit colour display, Intel XScale 400MHz CPU, USB for peripheral devices, PC, printer, also Bluetooth communication. Backlit keyboard, rechargeable Li-Ion battery pack. Machine train alignment - 14 machines. Alignment results in 3 quick steps, thermal growth computation. Rotalign Ultra Reader software included.

Pruftechnik 1500mm Length Tension ChainsPRU,AL12.116 (4946) AU1500mm length tension chains for PRU,ROT-ULTRA.

Industrial Process Calibrators Ametek PPCE 700 Bar Pressure CalibratorAME,PPCE MYHigh pressure calibrator with pump 700 Bar (10,000psi). Digital display with 5 digit resolution. Accuracy over 70 Bar ±0.07. Accuracy below 70 Bar ±0.35.Current and voltage measurement ranges 4 to 20mA, 0 to 50mA & 0 to 30V.

Industrial Process Calibrators cont’d.Beamex MC5 Multifunction Calibrator NATA CertifiedBEA,MC5 (4731) AU

NATA certified MC5 provides calibration capability for pressure, temperature, electrical and frequency signals. HART communication and CMX light software provided. Calibration results can be stored or printed. Performs as a field-entry device (FED) allowing for the recording of non-calibration related

maintenance results. Pressure modules included, -1 to 20 Bar and 600 Bar (up to 1,000 Bar with optional external transducers). DC voltage & current, frequency, and pulse measurement. RTD, thermocouple, and resistance simulation & measurement.

Beamex MC5-IS Multifunction Calibrator NATA CertifiedBEA,MC5-IS (4732) AU/MY

NATA certified MC5-IS provides calibration capability for pressure, temperature, electrical and frequency signals. HART communication and CMX light software provided. Calibration results can be stored or printed.

Performs as a Field-Entry Device (FED) allowing for the recording of non-calibration related maintenance results. Pressure measurement range, -1 to 20 Bar and 600 Bar (up to 1,000 Bar with optional external transducers). DC voltage and current, frequency, and pulse measurement. RTD, thermocouple, and resistance simulation and measurement.

Beamex MC6 Advanced Field CalibratorBEA,MC6 (4727) AU

NATA certified MC6 provides calibration capability for pressure, temperature, electrical and frequency signals. HART communication and CMX light software provided. Calibration results

can be stored or printed. Performs as a field-entry device (FED) allowing for the recording of non-calibration related maintenance results. Pressure modules included, -1 to 20 Bar and 600 Bar (up to 1,000 Bar with optional external transducers). DC voltage & current, frequency, and pulse measurement. RTD, thermocouple, and resistance simulation & measurement. Colour touch screen.

Crystal nVision Pressure Calibrator 30 Bar IS NATACRY,NVISION-30-NATA (4757) AU

Intrinsically safe pressure calibrator. Displays real-time recorded data graphically on a high res screen with ability to zoom into specific events. 500,000 data point memory records all data from all enabled screens from two modules simultaneously. Fastest logging interval 10 readings/sec.

Configured with MA20 current, voltage and switch test module and 30 Bar pressure module, accuracy to 0.025% of reading. Includes hand pump and CPF (finger tight to 700 Bar) fittings.

Crystal XP2i 15psi (1 Bar) NATA with Druck PV411 Hand Pump

CRY,XP2I CAL KIT 1 (4735) AU15psi (1 Bar) pressure gauge and Druck PV411 hand pump calibration kit. Nata certified accuracy, ±0.1% of reading between 20 to 100% of full scale, ±0.02% of full scale between 0 to 20% of full scale. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

General Industrial & Process Management www.techrentals.com.au

Page 45: normas quipment-solutions-guide

43

Industrial Process Calibrators cont’d. Crystal XP2i 100psi (7 Bar) NATA with Druck PV411 Hand Pump

CRY,XP2I CAL KIT 7 (4743) AU100psi (7 Bar) pressure gauge and Druck PV411 hand pump calibration kit. Nata certified accuracy, ±0.1% of reading between 20 to 100% of full scale, ±0.02% of full scale between 0 to 20% of full scale. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Crystal XP2i 5,000psi (345 Bar) NATA with Druck PV411 Hand Pump

CRY,XP2I CAL KIT 345 (4765) AU5,000psi (345 Bar) pressure gauge and Druck PV411 hand pump calibration kit. Nata certified accuracy, ±0.1% of reading between 20 to 100% of full scale, ±0.02% of full scale between 0 to 20% of full scale. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Druck DPI603 2-NATA 2 Bar Pressure CalibratorDRU,DPI603-2-NATA (4738) AUDRU,DPI603-2 MY0.075% FS Accuracy includes pump for vacuum and pressure. Unit will pump up to 2 Bar pressure and -850mBar vacuum. Measurements can be made to 2 Bar positive pressure and -1Bar vacuum. The unit has a 24V energising voltage. Monitors loop current to 55mA DC loop voltage to 50V. Sealed to IP65. Rechargeable battery operated. Unit can display in 24 different units. BSP 1/8 interface.

Druck DPI603 20 Bar Pressure Calibrator DRU,DPI603-20 MYAccuracy 0.075%fs. Pumps up to 20 Bar pressure & -850mBar vacuum. Measures up to 20 Bar pressure and -1 Bar vacuum. In-built 24V energising voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface 1/8” bsp. Battery operated.

Druck DPI104 350 Bar Pressure Calibrator & HTP1 Hydraulic PumpDRU,DPI104-350 MYRange 0 to 350 Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all @ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1μA resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA & unregulated supply 24V ±10% current 50mA. Pressure switch status. Pressure media oil, water & non corrosive gases. Battery operation 10h or mains operation via charger. Complete with a full range of pressure connection adaptors.

Druck DPI610-2-NATA 2 Bar Pressure Calibrator DRU,DPI610-2-NATA (4737) AUDRU,DPI610-2 MYPneumatic pressure calibrator including pump and current voltage standard. Pressure range -1 to 2 Bar, ±0.025%fs. Voltage input ±50VDC, ±0.05%rdg, ±0.004%fs. Current input ±55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to 40°C, ±1 (ambient) switch open/closed. Voltage output 10VDC, ±0.1% or

24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes flexible hose kit. Pump includes screw adjustment.

Industrial Process Calibrators cont’d. Druck DPI610-20-NATA 20 Bar Pressure Calibrator NATA CertificationDRU,DPI610-20-NATA (4751) AUDRU,DPI610-20 MYPneumatic pressure calibrator including pump and current voltage standard. Pressure range -1 to 20 Bar ±0.025%fs. Voltage input ±50VDC, ±0.05%rdg, ±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10 to 40°C ±1°C (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8f, includes flexible hose kit. Pump includes screw adjustment.

Druck DPI610-400-NATA 400 Bar Pressure Calibrator DRU,DPI610-400-NATA (4768) AUDRU,DPI610-400 MYHydraulic pressure calibrator including pump and current voltage standard. Pressure range 0 to 400 Bar ±0.025%fs. Voltage input 50VDC, ±0.05%rdg, ±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to 40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V ±5%. Current output 0 to 24mA, ±0.05% rdg, ±0.01%fs. Data logger stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes flexible hose kit. Pump includes screw adjustment.

Druck DPI615-20-NATA 20 Bar Pressure CalibratorDRU,DPI615-20-NATA (4750) AU

Pneumatic pressure calibrator including pump and current voltage standard. Pressure range 0 to 20 Bar ±0.025% FS. Voltage input ±50VDC ±0.05% rdg ± 0.004% FS. Current input ±55mA ±0.05%rdg ±0.004%FS. Temperature -10 to 40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1%

or 24V ±-5%. Current output 0 to 24mA ±0.05%rdg ±0.01%FS. Data logger stores upto 10,000 values. mA ramp configurable. Pressure port G 1/8 female, includes flexible hose. Pump includes screw adjustment.

Druck PV411A Multifunction Hand Pump KitDRU,PV411A (4789) AU/MYProvides up to 700 Bar hydraulic, 40 Bar pneumatic pressures and vacuum to -950mBar. Built-in stroke adjuster, lower pressure fine control and tamper proof overpressure protection.

Druck UPS III-IS Intrinsically Safe Loop CalibratorDRU,UPS III-IS (4777) AUMeasure or source 0 to 24mA and provide 24V loop power. 50 VDC measurement and continuity. Accuracy 0.015% of reading, Hart compatible. Dual mA and % readout, linear or flow. It is an essential tool for loop testing, instrument maintenance and valve set-up, with an easy-to-read display and simple-to-use time saving features.

Emerson Process Management 375 Field Communicator EME,375 (4795) MY Will configure, test, and diagnose your HART® and Foundation FieldBus devices. Able to communicate with any device, by any manufacturer. Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS PC Suite Software.

Emerson 475 Hart CommunicatorEME,475 (4794) AU/MYWill configure, test, and diagnose your HART® and Foundation FieldBus devices. Able to communicate with any device, by any manufacturer. Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS PC Suite Software.

General Industrial & Process Management www.techrentals.com.auGeneral Industrial & Process Management www.techrentals.com.auGeneral Industrial & Process Managementwww.techrentals.com.au

Page 46: normas quipment-solutions-guide

44

Industrial Process Calibrators cont’d.Softing BC-600-PB Profibus Tester 4SOF,PROFIBUS-4 (4723) AUAllows full testing of live PROFIBUS segments with minimum influence on their operation. Detects transient faults that occur sporadically. Test for non operation PLCs or suspicious devices. Simultaneous analysis of both bus physics and bus communication. Master simulator and Topology scan. Expert tests: frame, oscillogram analysis and trigger input/output. Long term trend measuring, preventive maintenance and detailed test reporting.

Fitting Set with 700 Bar HoseFIT,HP MYFitting set (max pressure = 10,000psi) for pressure calibrators. Female connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inch BSP & NPT; 1/2 inch BSP & NPT.

Fitting Set With 20 Bar HoseFIT,LP MYFitting set (max pressure = 10,000psi) for pressure calibrators. Female connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP & NPT; 3/8 inc BSP & NPT; 1/2 inch BSP & NPT.

Fluke 70 Bar Pressure Transducer to suit Fluke Calibrators 725 & 744FLU,700P08-70BAR (4762) AUFor use with the Fluke 744 & 725 industrial calibrators. Pneumatic system range 0 to 70 Bar, resolution 7mBar, reference uncertainty 0.025%. Connection 1/4 NPT and 1/4 ISO. Includes 700PTP-1 pressure pump. (Note the pump will operate to 41 Bar).

Fluke 690 Bar Pressure Transducer to suit Calibrators 744 & 725FLU,700P31-690BAR (4771) AUFor use with the Fluke 744 & &25 industrial calibrators. Range 0 to 690 Bar, reference uncertainty .025%. Connection 1/4NPT and 1/4 ISO. Includes 700HTP-1 pressure pump.

Fluke 7 Bar Pressure Transducer & Pump to suit FLU,744 & FLU,725FLU,700PD6-7BAR (4745) AUFor use with the Fluke 744 & &25 industrial calibrators. Range 100 to 690kPa, reference uncertainty .025%. Connection 1/4 NPT and 1/4 ISO Includes 700LTP-1 pressure pump.

Fluke 718 300G Pressure CalibratorFLU,718-300G (4755) AUPressure source and milliamp measurement. Pressure specs -83 to 2068kPa ±0.05% of range. Max pressure 2.6MPa. Current specs: 0.0001mA resolution, accuracy 0.015%. Calibrate P/I (pressure to current) transmitters, measures pressure via a 1/8 inch NPT pressure fitting and an internal pressure sensor, source pressure, measure current up to 24mA, simultaneously display pressure and current measurements, supplies loop voltage, calculates percentage in percent mode, calculates mA error in percent error mode.

Fluke 719 2 Bar-30G Pressure Calibrator including Electric PumpFLU,719-30G (4740) AU2Bar, includes pump and precision 4 to 20mA measurement and source capability. The pump in this instrument is electric. Uncertainty 0.025%. Precision pressure adjustment vernier. Range -850mBar to 2Bar. Resolution 0.1mBar. 4 to 20mA resolution .001mA .015%rdg + 2 counts.

Industrial Process Calibrators cont’d.Fluke Pressure Calibrator 8Bar includes Electric PumpFLU,719-100G MY8Bar, includes pump and precision 4 to 20mA measurement and source capability. The pump in this instrument is electric. Uncertainty 0.025%. Precision pressure adjustment vernier. Range -850mBar to 8Bar. Res-olution 1mBar. 4 to 20mA resolution 0.001mA 0.015%rdg + 2 counts.

Fluke 725 Process CalibratorFLU,725-NATA (4784) AUFLU,725 MYDC voltage measurement 0.025%, 300V max, source 0.02%, 11V max. DC current measurement 0.025%, 110mA max, source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 1 1kΩ max. Frequency measurement 5 counts 1Hz to 50kHz, source 1 count 20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC. Pt100 RTD measurement 0.5ºC, source 0.2ºC. Measures and simulates 4 to 20mA, t/c E,N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates from drycell batteries. (Includes NATA calibration - AU).

Fluke 726 Process CalibratorFLU,726 MYPrecision multifunction process calibrator. DC voltage measurement. 0.010% 30V max, source 0.010% 20V max. DC current measurement. 0.010% 24mA max, source 0.01% 24mA max. Resistance measurement 0.015% 4kΩ max, source 0.01% 4kΩ max. Frequency measurement 5 counts 1Hz to 15kHz, source 1 count 20Hz to 15kHz. Will measure and simulate 4 to 20mA, TC E N J K T B R S and C, 2, 3 and 4 wire RTDs and frequency. Loop power supply at: 24V, 22mA. Pulse Source 10k and read 100k. The unit operates from drycell batteries.

Fluke 743 Calibrator FLU,743B MYIncludes RS232 interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V max. DC current measurement 0.025%, 110mA max, source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40 to 500Hz, source 1 count 20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4 to 20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Can use scaling factors for measurement & source. Built in calculator. Autostep function. Allows user entered values. Operates as an 8k point data logger. Note PC software only supports 15 tags.

Fluke 744 DOC Calibrator with HartFLU,744 (4782) AU/MYDocumenting process calibrator which includes HART

communication protocols for communicating with and setting up smart transmitters. RS232 interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA max. Resistance measurement 0.05%, 11kOhm max, source 0.01% 11kOhm max. Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4~20mA, t/c E, N, J, K, T, B, R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling factors for measurement & source. Built in calculator. Autostep function. Allows user entered values. Operates as an 8k point data logger. Note PC software only supports 15 tags.

General Industrial & Process Management www.techrentals.com.au

Page 47: normas quipment-solutions-guide

45

Industrial Process Calibrators cont’d.Fluke 773 Milliamp Process Clamp MeterFLU,773 (4779) AUMeasure 4 to 20mA control lines, PLC loops, transmitters or any 4 to 20mA line without breaking the loop. Capable of 0 to 20.99mA and 24 to 100mA with clamp. Source and simulate mA and voltage signals in circuit. 4 to 20mA scaled o/p.

Fluke 789 Process MeterFLU,789 PROCESSMETER (4786) AU/MYStandard multimeter functions with 2 to 20mA sink and source capability, including a 24V supply. HART 250Ω resistor, 20mA drive into 1,200Ω. Simultaneous mA and % of scale readout on mA output. 25% manual step plus auto step and auto ramp on mA output. Min/max/average/hold/relative modes. Double size dual display. Accuracy, VDC 0.1% +1, VAC 0.7% +2, mA DC 0.05% +2, frequency 0.005% +1.

Jofra DPC-500 Documenting Pressure Calibrator 1000 Bar NATAJOF,DPC-1000-NATA (4775) AUDocumenting pressure calibrator is used for high precision calibration of pressure gauges, pressure transmitters, digital manometers, pressure switches, overpressure protection

valves etc. Measure pressure at 1,000 Bar or 14,500psi, voltage 0 to 10V, current 0 to 20mA and 4 to 20mA, and supplies 24VDC as source for transmitters. Accuracy ±0.025% F.S. Supplied with Druck PV212 1,000 Bar hand pump and calibration software. 15 user selectable engineering units including user defined. Nata Calibrated.

SI PC6 20 Bar NATA Pressure Calibrator & Pump SI,PC6-20-NATA (4753) AUBasic accuracy 0.025%. Range output pressure to 20 Bar, output vacuum to -1 Bar. NATA certified Instrument. Measures voltage 0~100mV (1μV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current 0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. Pressure switch status. Battery operation 10h or mains operation via charger.

SI PC6 35 Bar NATA Pressure Calibrator & Pump SI,PC6-35-NATA (4759) AUBasic accuracy 0.025%. Range is 35 Bar. Measures voltage 0~100mV (1μV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current 0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. Pressure switch status. Complete with a full range of pressure connection adaptors. Record logging capability 444 and RS232 interface download to spread sheet files. Battery operation 10h or mains operation via charger.

SI PC6 700 Bar Pressure Calibrator and HTP1 Hydraulic Pump NATA CalibratedSI,PC6-700-NATA (4773) AU/MYRange 0 to 700 Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all @ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1uA resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current 30mA and unregulated supply 24V ±10% current 50mA. Pressure switch status. Pressure media oil, water & non corrosive gases. Battery operation 10h or mains operation via charger.

Wet & Dry Block CalibratorsFluke 9141 Dry Block Temperature Calibrator 50 to 650ºC FLU,9141-NATA (4835) AURRange 50 to 650ºC, basic accuracy 0.5%. Insert hole sizes 1.6mm(1/16”), 3.2mm(1/8”), 4.8mm(3/16”), 6.4mm(1/4”), 9.5mm(3/8”) and 12.7mm(1/2”). Includes PC software and interface cable. Heating time 1min to 650 deg C. Cooling 25min from 650 to 100 deg C. Well depth 4.875”. Stabilization time 7min.

Fluke 9150 Thermocouple Furnace 150 to 1,200°C NATA CalibratedFLU,9150-NATA (4840) AUTemperature range 150 to 1,200°C. Stability ±0.5°C, display accuracy of ±5°C across entire range. Display resolution 0.1 to 999.9°C, 1° above 1,000°C. Well diameter 32mm, well depth 140mm, insert type 9150 A, 0.4, 6.4, 9.5, 3.2, 12.7mm. Heating time 35min to 1,200°C, cooling time 140min.

Fluke 9170-R Dry Block Temp Calibrator -45 to 140°CFLU,9170-R-NATA (4825) AUFLU,9170-R MYMetrology well calibrator. Temperature range -45 to 140°C with built in reference thermometry. Reference input accepts (not supplied) 100, 25 and 10 ohm PRT’s. Display accuracy ±0.1°C, stability ±0.005°C full range, resolution 0.001°C. Well depth 160mm (6.3”), insert type A, 3 x 6.4mm(1/4”), 4.8mm(3/16”), 3.2mm(1/8”), 5.9mm(3/8”). Large LCD, numeric keypad and on screen menus.

Grant GR150-S5 Temperature Bath NATA CalibratedGRA,GR150-S5-NATA (4820) AUWater/oil bath and circulator for calibrating temperature probes and analytical procedures. Temperature ranges from ambient to 100ºC with water and 150ºC with silicon oil. Requires 3L oil (not supplied). Stability 0.005ºC, uniformity 0.02ºC and display resolution 0.1ºC. Tank size 300mm W x 150mm D x 150mm H. Features include digital temperature controller and display, pump, timer, alarms, offset adjustment and more.

Jofra CTC-650A Temperature CalibratorJOF,CTC-650A MYExceptionally fast and has deep immersion depths of 110mm (4.3 inch). Heats up to the maximum temperature in just 20 minutes. Temperature range: 33 to 650°C. Accuracy: 0.9°C. Stability: 0.1°C. Multi-Hole insertion tube: 1/4”, 1/8”, 3/8” and 3/16”.

Jofra CTC-1200A Temperature CalibratorJOF,CTC-1200A MYCompact temperature calibrator. Lightweight, portable for lab and general use. Temperature range: 572 to 2200ºF (300 to 1205ºC). Excellent Performance Characteristics. Accuracy: ±4.0ºF (±2.0ºC). Stability: +1.0ºF (+0.5ºC). Stability Time: 20 minutes. Display in F or C to 0.1 resolution. Fast cooling and heating. User-selectable Slope Rates for controlled. Thermo switch

testing. Self Diagnostics includes Semi-Auto Switch Test and Hysteresis Test. Size of thermowell/insert: 6.5mm & 10mm. 1/4” probe. 1/2” probe.

Strip Chart RecordersRototherm C105 10,000psi Pressure RecorderROT,C105 MYSingle pen recording. (±)1% span maximum. 1/2”(M) BSP connection. 255 mm diameter, circular chart paper.

General Industrial & Process Managementwww.techrentals.com.au

Page 48: normas quipment-solutions-guide

46

Strip Chart Recorders cont’d.Yokogawa DR130 Hybrid 20 Channel Recorder FDDYEW,DR130 (4010) AUInput unbalanced floating 20mV~50VDC, TC, RTD and contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width 150mm. Data can be saved to 500k of internal RAM either directly or due to alarm conditions. The saved data can be copied to a 3.5” FDD file suitable for inclusion in standard spread sheet programmes.

High Speed Waveform RecordersHioki 8835-HD520 520Mb PCMCIA Hard Disk for HIO,8835 & 8841HIO,8835-HD520 (4122) AUPCMCIA interface complete with 520Mb card. Data can be stored in several formats: as a binary memory file for replay on the recorder; as a CSV text file compatible with Excel; as a BMP screen dump for a Word document, etc; as a single or dual FFT binary file for replay on the recorder. The recorder setup can be saved for future applications requiring the same settings. Data media is PCMCIA Type III compatible with many laptop computers.

Hioki 8841 8 Analogue, 16 Channel Memory RecorderHIO,8841 (4117) AU

Memory 12bits x 4 megawords/ch for 2 analogue ch, to 1 megawords/ch for 8ch. In-built FDD, type III PCMCIA card slot (for flashcard

& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real time record, RMS, real time/memory, X-Y memory, FFT. Trigger functions level, window in, window out, voltage drop, RMS level, cycle, logic pattern trigger 1,0 or X (disregard). When using logic channels, logic probes must be rented separately. Measurement range 400VDC, 240V RMS, low pass filters 5Hz, 500Hz, 5kHz or 100kHz, input coupling DC, GND, AC. Large 10.4” colour TFT display for settings and waveform display, wide thermal printer fitted. On screen help function. All settings and waveforms can be saved to media, waveforms can be saved as binary, text or bmp files.

Hioki 8842 16 Analogue, 16 Logic Channel Waveform Recorder

HIO,8842 (4150) AUMemory 12bits x 16 megawords/ch for 2 analogue ch, to 2 megawords/ch for 16 ch. Analogue input channel ranges 10mV to 50V per div, 10X div, 400VDC,

240VAC RMS max. In-built FDD, type III PCMCIA card slot (for flashcard & HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real time record, RMS, real time/memory, X-Y memory. Trigger functions level, window in, window out, voltage drop, RMS level, cycle, logic pattern trigger 1,0 or X (disregard). When using logic channels, logic probes must be rented separately. Measurement range 400VDC, 240V RMS, low pass filters 5Hz, 500Hz, 5kHz, or 100kHz, input coupling DC, GND, AC. Large 10.4” colour TFT display for settings and waveform display, wide thermal printer fitted. On screen help function. All settings and waveforms can be saved to media, waveforms can be saved as binary, text or bmp files.

Hioki 8860 8 Channel High Speed Memory RecorderHIO,8860 (4129) AU

High speed memory recorder, 20MS/s sampling rate, 8 analogue channels, 16 logic channels, built in printer. 512MW or direct access memory, 60GB hard drive built-in, PC card type II slot up to 4GB ATA flash card (optional) USB, LAN interface and large colour screen.

High Speed Waveform Recorderscont’d.

Hioki 8870-20 Memory Hicorder 2 Analogue & 4 Logic Channels

HIO,8870-20 (4101) AUChannels; 2 analogue and 4 logic (standard equipment, logic grounds are common with

instrument ground), 10mV to 50V/div, 12 ranges, resolution: 1/100 of range, DC 400V, DC to 50kHz (-3dB). 100μs/div to 5 min/div, 20 ranges, at 100 points/div resolution, three steps of time-axis magnification from 2× to 10×, and nine steps of time-axis compression from 0.5× to 0.001. MEM (high-speed recording), 12bits × 2M-Words/ch, CF Card Type I slot × 1, up to 1GB. Display 4.3 inch WQVGA-TFT colour LCD (480 × 272 dots). One USB 2 high speed mini-B receptacle: transfers files from the installed CF card to a PC when connected. Numerical calculation, cursor readout, scaling function, screen copy, gauge display, waveform data/setting configurations backup, start condition retention, auto-save, instantaneous value or RMS value display (only DC and 50/60Hz). Use with the AC adapter, 100 to 240VAC (50/60Hz) 30VA max. Battery pack; continuous use 2h (AC adapter has priority when both are used). 12VDC supply: 10 to 16V, 10VA Max.

Hioki 8938 FFT Input Signal ModuleHIO,8938 (4138) AUFFT Module with anti-aliasing filter. Frequency range DC to 400kHz, sampling rate 1MS/s. Maximum input voltage 400VDC, 240V RMS.

Hioki 9306 4 Channel Contact & Digital Logic ProbeHIO,9306 (4123) AUContact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders. Threshold digital >1.4V maximum input 50V. Contact closure input, 2k input resistance 30V allowable input. Response time 2μs.

Hioki 9320 4 Channel Contact & Digital Logic ProbeHIO,9320 (4140) AUFor HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders, 4 channels per probe, max of 4 probes per recorder. Threshold

digital selectable 1.4V, 2.5V & 4V. Response time 500ns max. Relay dry contact detection. Max allowable input 50VDC.

Hioki 9321 Line Logic ProbeHIO,9321 (4124) AUFour channels (insulated) per probe. Detection of 60 to 150VAC, 170 to 250VAC, 20 to 150VDC & 70 to 250VDC in 2 ranges. Response time slope rise 1ms, fall 3ms. Max input low range 150V RMS, high range 250V RMS. Max rated voltage to earth 250V RMS. Connector cable 1.5m. Probe tip cable 1m.

Hioki 9335 Wave Processor Software for Hioki 8835, 8835-01, 8841, 8842HIO,9335 (4155) AUWaveform Processor software, displays, converts to CSV, calculates and prints waveforms with a PC. Review stored binary files from Hioki 8835, 8835-01, 8841 and 8842 memory recorders. Only way stored binary files can be viewed on a PC without having to re save them with memory recorder as text files.

Hioki 9725 Memory Viewer SoftwareHIO,9725 (4157) AUData processing software for Hioki 8860 High Speed Memory Recorder. Functions: file loading, maximum loadable data size 2GW file saving, measurement of data binary, partial saving between A/B cursors is possible. Screen images BMP and PNG, calculation results. Display of saved binary files, displayable channels per sheet analogue 32, logic 16 channels. Displayable sheets 16.

General Industrial & Process Management www.techrentals.com.au

Page 49: normas quipment-solutions-guide

47

Data LoggersDatataker CANGATE Gateway & Garmin 5Hz GPSDE,CANGATE (4236) AU

Interface to allow dataTaker loggers and PC (via RS232) to access CANBUS networks including J1939 & OBD2. The device also includes a Garmin 5Hz GPS system.

DataTaker DT600 Data LoggerDE,DT600 MYIncludes LCD display enabling use as a measuring instrument if pre-programmed for channel parameters. 10 differential or 30 single-ended channels. 25 channel/sec. 4 TTL/CMOS digital inputs. 3 counter channels up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LEDs. Internal memory for up to 13,000 data points with optional memory card to 170,000 readings. RS-232C data communications port and RS-485 port for networking up to 32 loggers. Maths processing included. Input ranges 25mV to 2.5VDC. Maximum sensitivity 2μV. Current 0.25 to 25ma. Current loop 4-20mA. Resistance up to 7,000 ohms. Thermocouples types B,C,D,E,G,J,K,N,R,S, & T from -250 to 1800ºC. Thermistors and RTD’s. Strain gauges. Supplied with determinal & decipher plus software. Operates from internal battery, external battery, or ac mains.

DataTaker DT80 5 to 15 Channel Logger with USB Memory Stick DownloadDE,DT80 (4232) AU/MY

Measures voltage, current, resistance and frequency. Up to 15 analogue (±30V) sensor inputs. Each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. 12 flexible digital channels. Expandable to 300 analogue inputs. Store up to 10 million data points in user defined memory.

Data Loggers cont’d.DataTaker DT80M 5 to 15 Channel Logger with Built in Modem

DE,DT80M (4234) AUIIncludes a built in GSM modem for internet access to the device supports 2G and 3G networks (GSM/

GPRS/EDGE/WCDMA). Measures voltage, current, resistance and frequency. Up to 5 analogue (±30V) sensor inputs. Each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. Store up to 10 million data points in user defined memory. Generally used at sample rates of 1Hz and slower.

DataTaker DT800 Data LoggerDE,DT800 (4231) AU/MYUniversal input channels 12

balanced or 42 unbalanced analogue channels. Eight bi-directional digital channels and 8 digital input channels. Solid state

multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be used with GPS systems. Measures V, 4 to 20mA, strain, TC, RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USB, Ethernet (10baseT) & PC card modem communications. Pluggable 64Mb memory card stores up to 300,000 (compressed) readings per Mb. Instrument stores 600,000 (compressed) readings in internal memory. Total memory capacity 10.2Mb (compressed).

General Industrial & Process Managementwww.techrentals.com.au

A CANBUS DIAGNOSTIC SOLUTION

A bus and truck manufacturer was alerted to an issue of premature wear on their vehicles braking systems. End user reports showed an unexpected and repeated need to replace brake pads on the rear wheels of several buses. This revelation represented a signifi cant fi nancial concern, and not just in increased maintenance costs. The lost time compounded across multiple sectors, would lead to an unacceptable drop in productivity.

It was necessary to pinpoint whether the problem was a result of component error, brake mechanics or driver operation. Only then could the appropriate course of action be taken to rectify the issue. That is when TechRentals was called to fi nd a diagnostic solution. Our customised analytical system comprising of a data logger, a Canbus interface, with mapping functionality and GSM telephony communication was implemented and installed on the fl eet.

The Canbus results determining speed, hand brake position, brake pedal compression, as well as gearing information and ratios were recorded and compiled for all the vehicles fi tted. This data was downloaded and overlayed on Google maps to provide a graphical representation. This allowed analysis of the timing at exact locations of every relevant operation that could concern a vehicles braking system. The precise positioning information, coupled with the visual representation of the terrain, meant that both geographical and environmental factors such as steep inclines or congested traffi c could be properly considered alongside the raw data.

While examining the operational patterns of the vehicles being investigated, it soon became apparent that drivers were using the hand brake for slow speed stopping instead of utilising the brake pedal. This was putting undue wear on the rear braking pads, thus leading to the early need for replacement. Once this was established to be the underlying problem, it was then simply a matter of updating the operators in correct braking procedure and retraining operators.

Page 50: normas quipment-solutions-guide

48

Data Loggers cont’d.Datataker DT85 48 Channel Logger with USB Memory Stick Download

DE,DT85 (4233) AUAnalogue inputs 32 isolated and 48 single

ended inputs. 2 x 4 digital input types. 2 x serial sensor ports, Modbus capability, 4 x SDI12 channels, USB memory stick interface for easy data and programming etc. Operating time on the internal battery is 1s sample 2.4h. 5s sample 3 days, 1min sample 1 month.

ETM 9900 Intelligent Modem and IO. Sends SMS MessagesETM,9900 (4290) AUCan send a user defined alarm message via SMS. Has 7 IO channels. Will provide alarm messages for instruments such as the ARL,NGARA,

PRO,VIBRA & the TSI,8520 & 30. Will operate for around 4 months on 2xD cell batteries when the alarm status is checked once per hour. Can be put on site and remotely programmed.

Fourier DAQPRO8 Battery Operated Hand Held 8 Channel Data LoggerFOU,DAQPRO-2 (4282) AU

Portable, hand held, battery operated 8 channel data logger. 16-bit resolution, built in graphic LCD, for setting up, graphical display of logged data. PC communications via USB interface. Signal inputs 0 to 24mA, 0 to 50mV, 0 to 10V. Temperature input via NTC 10kΩ, 100kΩ, range -25 to 150ºC, PT100 range -200 to 400ºC, T/C ranges J type, -300 to 1500ºC, K type -250 to 1100ºC, T type -200 to 400ºC. Frequency input one channel only, 20 to 4,000Hz, sensitivity 20mV, pulse counter one input 0 to 65,000 counts. Memory capacity 512KB, sampling rates from 1s/h to 4,000s/s. Supplied with analysis and setting up software.

Hioki 3641-20-Kit Temperature & Humidity LoggerHIO,3641-20 MYTemperature and humidity logger includes: 1 x RS232C and 1 x USB communication base, utility software,RS232C and USB interface cables. Environment conditions for operation -20 to 70ºC, 80%RH (no condensation). Accuracy: temperature -40 to -0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical between ±5 to ±10% depends on temperature and humidity range. 8000 data points x 2 channels, recording interval 2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.

Hioki 3641-20-Kit of 8 Temperature & Humidity LoggersHIO,3641-20-KIT (4256) AUKit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1 x USB communication base, utility software, RS232C and USB interface cables. Environment conditions for operation -20 to 70ºC, 80%RH (no condensation) Accuracy: Temperature -40 to

-0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical between ±5 to ±10% depends on temperature and humidity range. 8000 data points x 2 channels, recording interval 2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.

Hioki 8421-01 16 Channel Data Logger with Colour DisplayHIO,8421-01 (4270) AU16 analogue, 4 pulse input channels data logger with colour

display, PCMCIA card slot, LAN interface built in, TCP/IP communication supports real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVDC, 1VDC, 10VDC, 60VDC, 1 to 5VDC fs. Thermocouples K,E, J, T, N, W (WRe5 to 26) R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200 to 800ºC. Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied.

Data Loggers cont’d.Hioki 8421-51 16 Channel Data Logger with Colour DisplayHIO,8421-51 (4271) AU16 analogue, 4 pulse input channels data logger with colour

display, PCMCIA card slot, LAN interface built in, TCP/IP communication supports real time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1VDC, 10 VDC, 60VDC, 1-5VDC f.s. Thermocouples K, E, J, T, N, W (WRe5-26), R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200 to 800ºC. Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 16MW, 512MB PCMCIA FLASH card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied. Improved common mode rejection -100dB or better when 50/60Hz, 140dB or better when 50Hz, using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling when using Pt100, improved temperature characteristics.

Hioki 8422-51 32 Channel Data LoggerHIO,8422-51 (4273) AU32 analogue, 4 pulse input channels data logger with colour display,

PCMCIA card slot, LAN interface built in, TCP/IP communication supports real time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60 VDC, 1-5V DC f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval is selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type of input signal. Internal Memory 8MB, 512MB PCMCIA FLASH card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse signal input cable all supplied.

Hioki Kit of Three 9322 Differential Probe High Voltage True RMS InterfaceHIO,9322-KIT (4119) AUUsed with many memory recorders, eg. Hioki 8835. Operating modes 3. DC mode for waveform monitor output DC to 3MHz, AC mode detection of power surge noise 1kHz to 10MHz. Rectified true RMS output of DC & AC voltages. 40Hz to 100kHz response speed 200ms or less. Max voltage DC 2kV, AC 1kV CATII, AC/DC 600V CATIII, balanced differential input 1/1,000 divider.

Testo 175-H1 Temperature & Humidity LoggerTES,175-H1 (4251) AULarge display. 3 year battery life, 1 million sample

memory. RH 0 ~100% ±2%, temperature -20~50ºC ±-0.4ºC . Includes USB interface to download data

Testo 177-H1 Logger with DisplayTES,177-H1 MYParameters: humidity/temperature/dew point. Sensors: humidity sensor/NTC (internal). Number of channels: 4. Measuring range: 0 to 100%RH and -20 to 70ºC (internal). Memory: 48,000 readings.

Testo 177-T4 Logger with DisplayTES,177-T4 MYParameters: temperature (C/F). Sensors: thermocouple type-K. Number of channels: 4 (external). Measuring range: -100 to 1,000 ºC (external). Memory: 48,000 readings.

See also Air Conditioning & Air Flow on page 58-59

General Industrial & Process Management www.techrentals.com.au

Page 51: normas quipment-solutions-guide

49

Pressure & Humidity TransducersDruck PTX1400-25 25 Bar Pressure Transducer 4 to 20mADRU,PTX1400-25 (4302) AUOutput 4 to 20mA output, 0 to 25 Bar input. Requires 9 to 28VDC, supplied with 12V, 500mA power pack.

Druck PTX 1400 600 Bar Pressure TransducerDRU,PTX1400-600 (4305) AUOutput 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.

Pressure Vacuum Gauges/RecordersCrystal XP2i Digital Logging Pressure Gauge 7 Bar NATA calibratedCRY,XP2I-100-NATA (4341) AU

Range 7 Bar resolution 0.1mBar. Accuracy 1.4 to 7 Bar ±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum ±17.5mBar. Has a 6000 point logging capability. Logging intervals from 1s up can be set. Logs either actual pressure, average pressure or average pressure with

max and min. Also logs on demand. 1/4 NPT connector. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Crystal XP2i Digital Logging Pressure Gauge 20 Bar NATA calibratedCRY,XP2I-300-NATA (4341) AU

Range 20Bar resolution 1mBar. Accuracy 4 to 20 Bar ±0.1% of reading. 0 to 4Bar ±-4mBar. It Has a 6000 point logging capability. Logging intervals from 1s up can be set. Logs either actual pressure, average pressure or average pressure with max and min. Also logs on demand. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Crystal XP2i Digital Logging Pressure Gauge 70 Bar NATA calibratedCRY,XP2I-1K-NATA (4342) AU

Range 70Bar resolution 0.001 Bar. Accuracy 14 to 70 Bar ±-0.1% of Reading 0 to 14 Bar ±14mBar. Has a 6000 point logging capability. Logging intervals from 1s up can be set. Logs either actual pressure, average pressure or average pressure with max and min. Logs on demand. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Crystal XP2i Digital Logging Pressure Gauge 210 Bar NATA calibratedCRY,XP2I-3K-NATA (4343) AUCRY,XP2I-3K MY

Range 210 Bar resolution 0.01Bar. Accuracy 40 to 200 Bar ±-0.1% of reading. 0 to 40 Bar ±-0.04 Bar. Has a 6000 point logging capability. Logging intervals from 1s up can be set. Logs either actual pressure, average pressure or average pressure with max and min. Also logs on demand. 1/4 NPT connector. Intrinsic and safety ratings registered under IECEx, ATEX.

Crystal XP2i Digital Logging Pressure Gauge 700 Bar NATA calibratedCRY,XP2I-10K-NATA (4344) AUCRY,XP2I-10K MY

Range 700 Bar resolution. 0.01 Bar accuracy. 1% of reading. Has logging capability. 6000 point pressure logging capability. Logging interval can be set from 1s up. Logs either Actual Pressure, Average Pressure, or Average pressure with Max & Min or log on demand. NATA Calibrated. 1/4 inch NPT connector. Intrinsic and safety ratings registered under IECEx, ATEX and DNV standards.

Flow Meters for Liquids & Gases See also Environmental Flow Meters on page 69

Flexim Ultrasonic Gas Flow MeterFLE,G608 (6156) AUUltrasonic flow meter is a clamp-on transit

time gas and liquid flow meter, 2-channel, with Zone 2 Ex-certification for use in hazardous areas. Supplied with three transducer pairs and a pipe wall thickness gauge; includes an integral data-logger with more

than 100,000 measured values, easy-to-use software for trending the data and an integral Lithium-ion rechargeable battery with AC adapter. The GLK transducers are suitable for 4 to 9mm wall thickness, the GLM 2 to 5mm and the GSM 2.5mm and greater. Utilises either Shear wave (standard) transducers, or Lamb wave (specialist gas) transducers. The Lamb wave transducers resonate the pipe wall to amplify the signal strength, thereby allowing it to measure applications at significantly lower pressures than the standard Shear wave transducers.

GE Panametrics PT878GC Ultrasonic Gas Flow MeterPAN,PT878GC-01 (6151) AUPortable non-contact gas flowmeter using transit-time principle. For

operation with ultrasonic transducer-kits (PAN,GC-RL302 & PAN,GC-RL319) - available separately. Compatible with metal or plastic pipes in the range 20 to 300mm. Suitable for use with compressed air, natural gas and other gases. Readout for flow velocity, actual or standard volumetric flow or mass-flow in numerical or graphic format. Internal logging for 100K flow data points. Infrared communications port for download to PC or printer interface. Rechargeable battery for 8h continuous operation.

Gas-flow Small Pipe Transducer Kit for PT878GCPAN,GC-RL302 (6153) AUAdvanced clamp-on ultrasonic transducer pair for use with Panametrics gas flowmeters. Operation at 1MHz for pipes in the range 20 to 55mm typical. General purpose use for process temperatures -40 to 176°C. Supplied with two precision gauged clamping fixtures for pipe range. Gas-flow Medium Pipe Transducer Kit for PT878GCPAN,GC-RL319 (6155) AUAdvanced clamp-on ultrasonic transducer pair for use with Panametrics gas flowmeters. Operation at 500kHz for pipes in the range 75-300mm typical. General purpose use for process temperatures -40 to 176°C. Supplied with set of three precision gauged clamping fixtures for pipe range.

GE Panametrics PT878 Ultrasonic Flowmeter

PAN,PT878 (6101) AU/MYPortable non-contact liquid flowmeter using transit-time principle. Includes transducers for pipe 50mm to 2mØ & temperatures -40 to 130°C (various alternative transducers available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically

1%. Data logging for over 100K data points. Analogue inputs compatible with temperature transmitters for energy-flow calculations. Outputs analogue 4 to 20mA, digital (pulse or frequency) and printer/computer (Infrared port). Large LCD display for velocity, volumetric and energy flow rate, totalised flow and trend data in alphanumeric and graphical formats. Rechargeable NiMH batteries and AC power supply/charger.

See Also GLO,FP111 Global FP111 Digital Water Velocity Meter on page 69

General Industrial & Process Managementwww.techrentals.com.au

Page 52: normas quipment-solutions-guide

50

Flow Meters for Liquids & Gases cont’d.

Panametrics PT878E Ultrasonic Liquid Flow Energy MeterPAN,PT878E (6102) AUPortable non-contact liquid flowmeter using transit-time principle.

Includes transducers to measure energy and transducers for pipe 50mm to 2mØ & temperatures -10 to 130°C (various alternative transducers available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically 1%. Data logging for over 100K data points. Outputs analogue 4 to 20mA, digital (pulse or frequency) and printer/computer (Infrared port). Large LCD display for velocity, volumetric and energy flow rate, totalised flow and trend data in alphanumeric and graphical formats. Rechargeable NiMH batteries and AC power supply/charger.

GE Panametrics PT878 Ultrasonic Liquid Flow MeterPAN,PT878T (6103) AUPortable non-contact liquid flowmeter using transit-time

principle. Includes thickness gauge and transducers for pipe 50mm to 2mØ & temperatures -40 to 130 degC (various alternative transducers available) with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically 1%. Data logging for over 100K data points. Analog inputs compatible with temperature transmitters for energy-flow calculations. Outputs analog 4 to 20mA, digital (pulse or frequency) and printer/computer (Infrared port). Large LCD display for velocity, volumetric and energy flow rate, totalised flow and trend data in alphanumeric and graphical formats. Rechargeable NiMH batteries and AC power supply/charger.

GE Panametrics 12 to 50mm TransducersPAN,C-LP-40NM (6108) AU//MYTransducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe 12 to 50mmØ. Complete with CF-LP-50M mounting bracket. Temperature range -40 to 120°C.

GE Panametrics -20 to 210°C TransducersPAN,C-PT-10HB (6110) AUHigh temperature transducer pair for PAN,PT868/878 transit-time flowmeter.Operates on pipe sizes 50mm~2m diameter. Working temperature range -40~230°C.

GE Panametrics -200 to 400°C TransducersPAN,OKS (6112) AUVery high temperature, wide range transducer pair for PAN,PT868/878 transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to 600mmØ. Uses special clamp system supplied. Appropriate protection and safe-handling equipment is required for fitting and operation at very high or low temperatures.

Polysonics Hydra SX30 Dual Frequency Doppler Liquid FlowmeterPOL,HYDRA-SX30-2 (6132) AUDual frequency doppler ultrasonic non-contact flowmeter. Velocity range 0.06 to 10m/s, accuracy ±1%. Pipe size range 12 to 5,000mm diameter. Data logging for 90,000 points, with PC software and interface cable for download via RS232C interface. Transducer temperature range -40 to 122°C. Analogue output 4 to 20mA. Battery operated, 12h continuous use (8h recharge).

Combustion, Flue & IndustrialGas Analysers See also Environmental Gas & Vapour Meters on page 63-64

Novatech O2 and CO2 Analyser/TransmitterNOV,1637-5 (5954) AUOxygen and carbon dioxide analyser for packaging atmosphere, general industrial and research use. Oxygen sensor reading 1ppm to 100% with 1% accuracy. NDIR carbon dioxide analysis 0 to 100% ±3% of full scale. 2 x 4 to 20mA outputs,

1 common & 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow rate with internal pump 100 to 500cc/min. AC operation.

Testo 335 Combustion Gas AnalyserTES,335 (5913) AU/MYPortable industrial flue gas analyser. Determines temperature (to to 1,000°C), draught/pressure (±40hPa), oxygen (21%), carbon monoxide (10,000ppm) and nitric oxide NO (3,000ppm) concentrations. Calculates carbon dioxide concentration, efficiency and flue gas loss. Threshold-protection of sensors, with 5X autodilution of CO to

50,000ppm. Separate sensor-socket with mini-probe for ambient temperature, and connection points for compatible differential-pressure devices. Built-in condensate-trap with warning and auto-switch-off. Internal memory [100 folders X 10 locations X 200 datasets each] for storage of measurement-protocols and data for printout. Supplied as kit with 335mm probe, cone and shield-plate, cordless printer and power supply. Rechargeable or AC operation (alkaline batteries used by printer).

Testo 350XL Portable Flue Gas AnalyserTES,350XL (5917) AU

Measures O2, CO, CO2 (measured by NDIR), NO, NO2 and SO2 concentrations plus draught, temperature, excess air, and gross/net efficiency values. Ranges: O2 0~25% vol, CO2 0~50%vol, CO with H2 compensation 0~10,000ppm with measuring-range extension

and selectable dilution factor, NO 0~3,000ppm, NO2 0~500ppm, SO2 0~5,000ppm, draught 50hPa, temperature -40~1,000°C. Includes switch-off and rinse function for CO cell and fresh air rinse for longer term measurements. Internal memory for 250,000 readings, with RS232C interface and software provided. Operation from mains or rechargeable battery.

Environmental Test Chambers/Ovens

Weiss WKL100/40 Temperature & Humidity ChamberWEI,WKL-100-40 (6218) AUEnvironmental chamber for temperature and humidity control. -40 to 180°C. Humidity range 10 to 98% (between 10 to 95°C). Max. Heating rate 2.5°C/min Max Cooling Rate 3.5°C/min. Test space volume 100l 540mm high, 490mm wide & 380mm depth. Programmable touch screen controller logs actual test temp. and humidity.

Includes Ethernet interface and control software. Single shelf, 50mm access port with large window to view samples.

Ultrasonic BathsSoniclean 2000HT Ultrasonic Cleaning BathSON,2000HT (6202) AUTank size 495mm W x 295mm D x 299mm H. Includes heater and timer.

General Industrial & Process Management www.techrentals.com.au

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 37.

Page 53: normas quipment-solutions-guide

51

SATELLITE PHONE RENTAL 1800 222 327

THINKTHINK RENTALSAVE MONEY –

Page 54: normas quipment-solutions-guide

52

Material Hardness TestersNon-Destructive TestingMicrometersPosition TransducersInclinometersForce GaugesLoad CellsWeighing & Counting Scales over 8kgVibration AnalysisSpeed Measurement

GE DynaMic Rebound Hardness Tester

GE,DYNAMIC (4936) AURebound hardness tester tests to ASTM A956 and DIN 50156. Will compensate for changes in testing direction. Provides readings in HV, HB, HRC, HRB, HS, HL & M/mm2.

Krautkramer DynaPocket Rebound Hardness TesterKRA,DYNAPOCKET (4932) AUBased on the Leeb’s method HL, utilising a 3mm tungsten carbide ball. Other hardness scales can

be selected, HS Shore, HB Brinell, HRB Rockwell B, HRC Rockwell C, HV Vickers and N/mm2 tensile strength. Choice of 9 material groups can be selected, they are St Low-alloy/unalloyed steel and cast steel, ASt Tool steel, SSt Corrosion resistant steel, GCI Gray cast iron, NCI Nodular graphite cast iron, AL Aluminium cast alloys, brS Brass, brZ Bronze, Cu Wrought copper alloys.

Proceq Equotip Hardness TesterPRO,EQUOTIP (4931) AUTest probe on a flexible lead. Probe type D is standard catering for most materials. Measurement ranges steels 80 to 650HB, 80 to 940HV, 20 to 68HRC, aluminium castings 20 to 160HB, cast iron 90 to 380HB, brass 40 to 170HB & copper wrought alloys 43 to 315HB. Test hardness must not exceed 940HV. Battery operated.

Non-Destructive TestingDefelsko 6000 Ferrous & Non Ferrous Coating Thickness Tester

DEF,POS-6000 (4870)Ferrous/Non Ferrous metal coating thickness tester with storage of up to 100,000 readings. Supplied with external probe, calibration standards and carry pouch. Measurement range 0 to 1500μm or 0 to 60 mils (selectable). Tolerance ±1μm +1% of reading 0-50μm, ±2μm +1% greater than

50μm. Resolution 0.1μm. Backglow display, HiLo limits audible & visible alerts when measurements exceed specified limits. Continually displays updates average, standard deviation, min/max thickness and number of readings while measuring. Built in USB, Bluetooth and Wifi for downloading readings.

Non-Destructive Testing cont’d. PosiTector 200 B & C Ultrasonic Coating Thickness GaugeDEF,POS-200ADV (4880) AU

Ultrasonic coating thickness gauge with type B & C Probes. Measures coating thickness over wood, concrete, plastics, composites etc. Will measure up to 3 individual layer thickness in a multi-layer system and features a graphic readout. Supplied with both B, 13 to 1000μm for wood, plastic and composites and C probes 50 to 3800μm for coatings on concrete, fibreglass etc. Accuracy is ±2μm +3% of reading.

Defelsko Positest Pull Off Adhesion Tester for Concrete & MetalDEF,POSITEST (4895) AU

Measures the force required to pull a specified test diameter of coating away from its substrate using hydraulic pressure. Pressure is displayed in both MPa and PSI on a precision dial indicator and can be related to the strength of adhesion to the substrate. Suitable for coatings on both metal and concrete surfaces. Conforms with standards ASTM D4541 and ISO 4624.

Olympus Epoch 600 Flaw DetectorOLY,EPOCH600 (4900) AUGeneral purpose ultasonic flaw detector.

Includes UT angle beam transducers 45, 60 & 70º, and Atlas dual element transducer. Stores images and data to micro SD card.

Olympus Ultrasonic Thickness GaugeOLY,38DL (4905) AUOperates with dual and single element

transducers, has colour transflective VGA screen. Includes datalogging capability. Does echo to echo measurements. Supplied with transducers to measure steel, cast, corroded steel, rubber, fibreglass and composites. Includes D7906-SM, M1036, M2008 M109-RM (inc delay line M202-RM) transducers.

Olympus 26mg Pocket Thickness GaugePAN,26MG (4910) AU/MYRange 1 to 500mm, fast min mode. Resolution 0.01mm. Probe operates -20 to 150ºC.

Olympus Ultrasonic Probe for OLY,38DL & PAN,26MGOLY,D790-SM (4909) AU

Ultrasonic high temperature probe for PAN,26MG & OLY,38DL. 5MHz 7.9mm tip diameter. Operating temperature range -20 to 500ºC.

PCWI 30kVDC Porosity (Holiday) DetectorPCW,DC30 (4885) AUDC Porosity (Holiday) detector. Detects pinholes in coatings above 150um on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display with battery indicator, display of voltage level. Alarm indicated on front panel, supplied with rechargeable battery, 10h charger, probe handle with neon and 2m length cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension. Dry conditions.

PCWI 40kV Pulse Porosity (Holiday) DetectorPCW,P40-PULSE (4890) AUPulse porosity (Holiday) detector. Detects pinholes in coatings and wrapping above 150μm on metal substrates such as pipes and tanks. Can be used on dry or wet surfaces. 0 to 40kV output, 4 digit LED display of voltage, alarm sensitivity setting

between dry and wet. Supplied with rechargeable battery, 10h charger, red probe handle and 2m length of rubber coated cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension and 80mm probe extension.

Material Hardness Testers

Physical Measurement www.techrentals.com.au

Page 55: normas quipment-solutions-guide

Tel.: 1300 132 992 • Fax: (03) 9540 0924 • [email protected] For worldwide representation visit www.olympus-ims.com

Olympus

ultrasound | phased array | eddy current | eddy current array | remote visual inspection | X-ray fluorescence

Olympus designs, manufactures, and globally markets a range of innovative nondestructive

testing and remote visual inspection instruments developed with a commitment to technology,

design, and user friendliness.

These products are used for inspection and maintenance in industrial and research fields

ranging from aerospace and energy to transportation and manufacturing. Olympus instruments

contribute to product quality and add to the safety of infrastructure and facilities. Olympus has

earned industry-wide reputations for providing cost-effective solutions and

excellent support and customer service.

Technologies

Ultrasound

Eddy Current

Remote Visual Inspection

X-Ray Fluorescence

Ultrasound Phased Array

Eddy Current Array

High-Speed Video

SolutionsCorrosion Testing

Weld Inspection

Security

Flaw Detection

Thickness Measurements

Automated Testing

Image Capture

Page 56: normas quipment-solutions-guide

54

Non-Destructive Testing cont’d. Phynix Surfix FN Ferrous/Non Ferrous Coating Thickness TesterPHY,SURFIX FN (4875) AUThickness tester with memory and statistics. Supplied with external probe, calibration standards and carry pouch. Measurement range 0 to 1,500μm or 0 to 60mils (selectable), tolerance ±1μm +3% of reading, resolution 0.1μm. Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min substrate thickness type F 0.5mm, type N 50μm. Calibration factory, zero, foil. Data memory 80 readings max. Interface infra-red download data to PC utilising hyper terminal.

Wylam Hill Paint Thickness GaugeWYL,PORTAPAINT MYRugged, fully electronic coating thickness gauges use magnetic and eddy current principles to measure coating thickness of ferrous metals, accurately and quickly.

Position TransducersMEL M5-200 4 to 20mA Optical Position TransducerMEL,M5-200 (5315) AUOptical distance measurement device 4 to 20mA output. Will measure distance from 240mm to 440mm with an accuracy of 0.06mm. Does not require a reflector on the surface of the device. Light spot diameter is 10mm. Light sensor is IP67. 4 to 20mA

transmitter is IP40. Will operate from 10 to 30V. Relay outputs indicate error condition. 1ms, 2ms or 20ms adjustable reaction time. Light source infrared 890nm invisible.

InclinometersGloi ALiSensor Level and Flatness System

GLO,ALISENSOR (5325) AUPrecision level system including an iPad with applications for Straighness, Squareness, Flatness, Spindle Parallelism, Spindal Perpendicularity, Shaft Level and Shaft Plumb. Angle can be measured to .001Deg and flatness can be determined to 0.0025mm. Includes a magnetic fixture.

Wyler Clinitronic 45 Inclinometer RS-232CWYL,CL45 (5326) AUResolution 0.01º. Accuracy better than 30arc sec. Display inclination in all common measurements. Includes RS232 interface for remote display of inclination and also logging. Settling time <5s.

Force GaugesAmetek Cadet 25 Digital Force GaugeAME,CADET-25N (4425) AURS232C interface. Range 0 to 25N (2.5kg), resolution 0.3N (1g), accuracy0.5% of full scale. Deflection 1mm. Display 4 digit LCD. Bi-directional with peak hold for compression & tension. NiCd operated. 1VDC recorder output.

Force Gauges cont’d.Hilti Safety Bolt Inspection SystemHIL,TESTER4 (4460) AU

Inspection system to test safety bolts (Safe RingBolts) on the exterior of buildings. The instrument will check the bolts to AS1891.4-2000 Industrial fall arrest systems and devices.Part 4: Selection, Use & Maintenance or to AS4488.2-1997 Industrial rope access systems Part 2: Selection, Use & Maintenance.

These tests need to be performed on a yearly basis on exterior connection points on building. These safe ring connection points will typically be used to suspend window cleaning harness systems.

Mecmesin AFG-1000NALC Digital Force GaugeMEC,AFG-1000NALC (4433) AURange 0 to 1,000N accuracy 0.1%. 5 digit back lit display. Peak data sampling rate 5kHz. 120% overload warning, display invert (reverse) function, dual max, max tension & max compression plus current reading.Outputs: analogue, RS232 & Mitutoyo. Accessories: test hook, compressionplate, 130mm & 30mm extension rods, rotary coupling. Mounting tapped holes x 2, M5 x 0.8 x 5.5mm deep max. Optional smart sensors can be used, such as TW60 static torque wrench.

Mecmesin TW60 Torque WrenchMEC,TW60 (4429) AURange to 60Nm, optional accessory to be used with MEC,AFG-1000NALC Force Gauge. Smart interface, as soon as plugged into force gauge scaled accordingly.

Load CellsAIC SG-AST-500 500kg S Type Load Cell with Panel Display AIC,SG-AST-500 (4405) AUTension and compression 500kg. Nominal output 2mV/V, max excitation 15VDC, IP67 protection, safe load 125%, compensated temperature range -10 to 40ºC. Thread M12 x 1.75P. Supplied with 2 x detachable rod end bearings, PM4 -SG-DC-5E load cell panel meter, power 12 to 48VDC, AC adaptor supplied, output 0 to 10V. Panel indication in kg.

Barlo MTC-150 150lb/68kg Load CellBAR,MTC-150 (4401) AURange 68kg compression and tension. Complete with interface operating from 12VDC or AC mains giving 0 to 2VDC output.

Barlo STC-10000 10,000lbs/5,000kg Load CellBAR,STC-10000 (4409) AURange 4,536kg compression and tension. Interface operates from 12VDC or AC mains. Output 0 to 5VDC. Display resolution 1kg.

Barlo STC-500 500lb/230kg Load Cell NATA CalibratedBAR,STC-500NATA (4403) AURange 230kg compression and tension. Complete with conditioning electronics. Output 0-2V. Uses 1/2 UNF thread. NATA calibrated.

Dillon ED2000 5,000kg Crane ScaleDIL,ED2000-5K (4452) AUComplete with shackles. Range 5,000kg. Accuracy 0.1%. Resolution 1kg. i.e. 20kg uncertainty. Units of measure: kg, kt, mt, & lb. Proof load 200% of rated load. Displays gross and net force. Continuous measurement and peak hold.

www.techrentals.com.au Physical Measurement

Page 57: normas quipment-solutions-guide

55

Weighing & Counting Scales Over 8kgAtlas TCS 60Kg Platform ScaleATL,TCS-60 (4441) AU60kG capacity. Rechargeable battery. 6 Digit display, 22mm height. Platform 450 x 600mm. Accuracy OIML III ±50g.

Vibration Analysis See also Noise & Sound Analysers on page 65

Fluke 810 Vibration TesterFLU,810 (5050) AU/MYTests rotating machinery to determine the status of gearing wear etc. Used to: Troubleshoot equipment and understand cause of failure. Commission new equipment and ensure proper installation. Includes triaxial accelerometer and laser tacho. Store and reports FFT images to your PC. Very simple output that reports Pass and Fail on machinery condition.

GTI Spindle Vibration Analyzer and Balancing System

GTI,IPAD3VAB (5040) AUThis system is based around an iPad. Measurement range ±196m/s2, frequency range 1.6 to 10kHz. Includes accelerometer on a 3m lead with a magnetic base and an optical position sensor. Measures Acceleration or Velocity giving a 0~20kHz FFT display.

Linear LSPC-1 1G Accelerometer DC to LFLIN,LSPC-1 (5034) AU/MYDesigned for very low force levels ±1G measurement range. Operates down to DC in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%. Shock Survivability 100g. Natural Frequency 100Hz.

Madgetech Ultrashock-EB Transportation LoggerMAD,ULTRASHOCK-EB (5025) AUUltrashock-EB transportation ambient temperature, humidity, barometric pressure and 3 axis shock acceleration logger. Ranges: -40 to 180ºC, 0-95%RH, 0 to 30PSIA (0-200kPa , -50g to +50g. Memory 23,831 readings per channel. Logging interval from 1 reading per 2s to 1 reading per 12h. Sampling rate 2ms. Includes RS232 interface and setting up, downloading, graphing software.

Profound Vibra Ground Vibration LoggerPRO,VIBRA (5023) AUDesigned for long term ground vibration logging. In-cludes a Geophone and remote alarm with flashing light. Velocity Range 0 to 100mm/s. 4 weeks opera-tion on 3 x D cell batteries. USB interface. Download possible while measuring. Full Windows analysis software included. IP65 case. Meets standards for

‘Vibration in buildings’ - Effects on structures’ and ‘Effects on persons in build-ings’, such as the DIN 4150 - part 2 and 3, DIN 45669 and the SBR 2002. The plus model also includes smart alarms which are frequency dependent, a built in modem to send alarms via SMS and email. A automatic daily status report. Also dominant frequency determination.

Load Cells cont’d. Dillon EDX 20T NATA Crane Scale with Wireless Remote

DIL,EDX-20T-NATA (4450) AUDigital crane scale. NATA calibrated 20T capacity, includes shackles and remote radio display/controller. Accuracy ±0.1%FS. Has peak hold. Will measure in kgF ibF or Newton.

Futek IHH500 Pancake Load Cell 2T CapacityFUT,IHH500-2T (4416) AUTheIHH500 display & LCF500-FSH02968 loadcell operate at up to 20 tonnes (50,000lb) in compression and tension. The IHH500 handheld display is a logging microcontroller which can

store up to 21000 points, it is powered by a rechargeable battery which can last for up to 30 hours depending on battery condition and load. It will operate from its mains charger if needed. The system has a simple ‘Tare’ function and can display ‘Max Hold’ using a single front panel key. The lead that connects the loadcell to the display is 1.6 Meters long. The load is connected via M33x2-Threads. There are two eye bolts supplied with the system, however the eye bolt capacity is 7 ton. The software is supplied on a USB flash drive/dongle.

Futek IHH500 Pancake Load Cell 20T CapacityFUT,IHH500-20T (4418) AUIH500 display and LCF500-FSH02968 load cell operate at up to 20 tonnes (50,000lb) in compression and tension. The IHH500 hand held display is a logging microcontroller which can store up to 21,000 points, it is powered by a rechargeable battery which can last for up to 30 hours depending on battery condition and load. It will operate

from its mains charger if needed. Has a simple ‘Tare’ function and can display ‘Max Hold’ using a single front panel key. The lead that connects the loadcell to the display is 1.6 Meters long. The load is connected via M33x2-Threads. Software is supplied on a USB flash drive/dongle.

Weighing & Counting Scales Over 8kg See also Balances & Scales Below 8kg on page 69

A&D Mercury FC-10K Counting ScalesAND,FC-10K (4435) AUHigh resolution 10kg scales with sample counting facility. Display resolution 1g, internal resolution 0.02g. Sample size user selectable – normally 10 pieces. Max count size up to 999,999. AC & NiCd battery operation.

A&D Mercury FG-150KB 150kg ScalesAND,FG-150KB (4437) AUCapacity 150kg, 0.05 resolution. Includes RS232 port. National Standards Commission approved (NSC).

A&D Mercury FS-15kg Weighing ScalesAND,FS-15KA (4434) AUHigh resolution 15kg scales. Display resolution 1g. AC & NiCad battery operation.

A&D HP-40KA 40kg Counting ScaleAND,HP-40KA (4436) AUCapacity 40kg with 0.5g resolution. Can be used to determine battery weight change with charge, etc.

Physical Measurement www.techrentals.com.au

Page 58: normas quipment-solutions-guide

56

Vibration Analysis cont’d. Profound Vibra Plus Ground Vibration Logger

PRO,VIBRA-PLUS (5023) AUDesigned for long term ground vibration logging. Includes a Geophone and remote alarm with flashing light. SMS & Email alarms are also possible. Velocity Range 0 to 100mm/s. 4 weeks operation

on 3 x D cell batteries. USB interface. Download possible while measuring. Full Windows analysis software included. IP65 case. Meets standards for ‘Vibration in buildings’ - Effects on structures’ and ‘Effects on persons in buildings’, such as the DIN 4150 - part 2 and 3, DIN 45669 and the SBR 2002.

Rion VA-10 Vibration AnalyserRIO,VA-10 MYMeasures acceleration, velocity and displacement. Stores 500 readings. LCD display with waveform, spectrum and data readout. Auto measurement function. Includes printer interface. Rion VA-11 Vibration AnalyserRIO,VA-11 (5042) AU/MYIncludes 2 pickup types hand held (PV55) and magnetic type (PV57). Measures acceleration, velocity and displacement. Displays RMS, peak and crest factor. Uses FFT to display power and vibration spectrum. Incorporates PCMCIA card fl ash memory for data storage. RS-232 interface available. PV57 1Hz to 5kHz, PV55 3Hz to 20kHz (velocity 3kHz, displacement 500Hz). Acceleration 0.02 to 316mm/s2 rms. Velocity 0.1 to 1,000mm/s rms. Displacement 0.003 to 28.3 (EQ PP). High pass fi lter 3Hz, 10Hz & 1kHz. Low pass 1kHz, 5kHz and 20 kHz. Stores 500 measurements.

Rion VA-12 Vibration AnalyserRIO,VA-12 (5040) AU

Includes magnetic pickup type. Will store measurements. Measures acceleration, velocity and displacement and displays it in either time or frequency domain. It will display rms, peak and crest factor. Uses FFT to display power and vibration spectrum. Incorporates SD card memory storage.

Svantek SV100 Whole Body Vibration AnalysisSVA,SV100 (5005) AU

Completely self-contained, integrated unit. Does whole body vibration dose (exposure) measurements, octave measurements, time domain record measurements and motion sickness measurements. Includes external alarm, car power adapter or will run from battery pack for >16hrs. USB interface for programming and download.

Vibration Analysis cont’d. Texcel ATM Explosion and Ground Vibration LoggerTEX,ATM (5036) AUTriaxial geophone and overpressure (airblast) micro-phone with logger used to determine explosion and ground vibration characteristics. Geophone range to ±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s, 0.109mm/s up to 55.9mm/s. Microphone range 80-dBL

to 140dBL, resolution 0.049Pa up to 122dBL (25Pa), 0.40Pa up to 140dBL (201Pa). Sample rate 20, 50, 100, 200, 500Hz & 1kHz. Bandwidth: geophone 4.5Hz to 500Hz, microphone 2Hz to 500Hz. Includes software and download cable. Internal memory 2Mb. Power internal 12VDC 7Ah batteries. Continuous operation 240h. Supplied with 90 to 260V 50/60Hz charger, recharge time 8h approx. 16 character LCD display, weatherproof enclosure, rated IP65. Operating temperature 0 to 70ºC, display 0 to 50ºC. Supplied with alarm light, reset button and 2 x 15m cable. External DC power supply cable also supplied.

TR Viblog Vibration and GPS LoggerTR,VIBLOG (5060) AUIncorporates a 3D accelerometer, a 3D gyroscope and a 10Hz GPS system. Logs 10 measurements per second. Records these measurements and also provides a Google Earth plot of the horizontal vibration and vertical vibration by location. A histogram of the vibration against velocity is provided also. The loggers battery lasts around 24hrs. Has suffi cient memory to record 10 samples per second over this time.

Speed MeasurementPhantom 53550 Radar Gun with Case and Tuning ForkPHA,53550 (5324) AUDoppler K band (24.150GHz) stationary radar gun. Pull the trigger and the speed display appears instantly. Invisible to all radar detectors.

Power requirements 10.5 to 16.5VDC, 13.5VDC nominal, 1.5A max, external source, connection via 1.8m coiled power cord with fused lighter plug. Operating environment -20 to 60ºC, 90%RH @ 37ºC (non-condensing). Accuracy ±0.17kph. Accuracy verifi cation tuning fork (K-Band), internal 90kph. Speed range 17 to 332kph.

Vehicle Counts PC2500 2 Channel Vehicle Volume & Speed Counter

VEH,PC2500 (5320) AUPrecision level system including an iPad with applications for Straighness, Squareness, Flatness, Spindle Parallelism, Spindal Perpendicularity, Shaft Level and Shaft Plumb. Angle can be measured to 0.001ºC,and fl atness can be determined to 0.0025mm. Includes a magnetic fi xture.

Physical Measurement www.techrentals.com.au

TR VMS CALIBRATION SERVICES Call for a quotation 1300 790 480

To minimise downtime, TR VMS provide a Booking Service to assist you in effectively and efficiently managing your equipment utilisation. Just call your nearest TR VMS office and arrange a date for the next available time slot. A quote will be provided stating that the equipment is to arrive at the TR VMS office the day before the work is due to be done. Simply sign the acceptance of the quote and return.

You have the choice of a Hypercal Calibration Service, for when the calibration is urgent, and your job will be “next on the bench” and in most cases with a one day turnaround. There is a surcharge for this service. Otherwise utilise the Standard Calibration Service with up to 10 business days for calibration.

Page 59: normas quipment-solutions-guide

57

Is your major project? Telecommunication • Construction • Road or Rail infrastructureNational Broadband Network • Power Generation

With over 35 years experience TechRentals technical sales staff will assist you in delivering the right test and measurement solution for your major project. Whatever the duration, the best solution will be tailored to your requirements, making this part of your project simple and easy.

With access not only to our vast inventory but to our global partners’ inventory you can be assured we will deliver the best solution for you.

PROJECT RENTALS www.techrentals.com.au

Page 60: normas quipment-solutions-guide

58

Air Conditioning & Air FlowAir Conditioner Valve BalancingConcrete Testing EquipmentUnderground Services LocationUtility Leak DetectionGround Penetrating RadarPipeline & Cavity InspectionMaterial Moisture MetersDistance Measurement & Surveying

Airflow AV2 100mmØ Anemometer NATA CertificationAIR,AV2-NATA (5837) AUSpecification as above but with NATA certification.

Airflow 36 Pitot TubeAIR,PITOT-36 (5816) AUPitot tube (36”) for use with manometers and micro manometers.

Alnor EBT-721-A3 Electronic MicromanometerALN,EBT-721-A3 MYDetachable multi-purpose digital manometer that can be used with the following test and balance tools, such as pitot, air foil, temperature, relative humidity probes or a 16-point velocity matrix. Differential pressure: ±15 in. H2O, (3735 Pa) 150 in. H2O maximum safe operating pressure. Absolute pressure: 15 to 40 in. Hg (356 to 1016 Hg). Velocity: 25 to 8,000 ft/min (0.125 to 40 m/s) pitot probes; 25 to 5,000 ft/min (0.125 to 25 m/s) air flow probe; 25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity matrix. Volume: 25 to 2,500 ft3/m (42 to 4250 m3/h) capture hood. RH: 0 to 95% RH (optional probe), Temperature: -40 to 250°F (-40 to 121°C) probe dependant. Standard comes with 2ft x 2 ft, upon request additional hood of 2ft x 4 ft and 1ft x 4ft hood would be provided.

Alnor EBT731 Balometer Electronic Balancing Tool

ALN,EBT-731 MYFeatures a detachable multi-purpose digital manometer that can be used with the following test and balance tools, such as pitot, static pressure probe or a 16-point velocity matrix. Volume Range: 25 to 2,500 ft cube/min (42 to 4250 m cube/h) with capture hood. Velocity

Range:25 to 2,500 ft/min (0.125 to 12.5 m/s) with velocity matrix. Unit comes with 2ft x 2ft,2ft x 4ft and 1ft x 4ft hoods.

CSS Portable Smoke Generating MachineCSS,COLT4 (5890) AUPortable smoke generator with variable smoke emission rate. Suitable for air flow visualisation, HVAC ductwork leak-testing, fire training and general work. Pump-free operation with smoke fluid supplied from consumable aerosol cans. Manual or continuous

operation and off-power facility. Maximum output 31 cubic meters/min at 1.5m visibility. Operation for 18min from one can at maximum capacity.

Druck DP1705 Manometer 0 to 20kPaDRU,DPI705 (5808) AUHandheld digital manometer range 0 to 20kPa, accuracy 0.2%. Displays all common engineering units.

Druck DPI705-IS Manometer 0 to 20kPa Intrinsically SafeDRU,DPI705-IS (5809) AUHand held Manometer 0 to 20kPa range. Accuracy 0.2%. Displays all common engineering units. Intrinsically Safe.

Shortridge ADM-860 Electronic ManometerSHO,ADM-860 (5812) AUElectronic micromanometer for air balance and similar applications. Measures differential pressure, air velocity and temperature using accessories included. Differential pressure range 0.0025 to 1500 mm water gauge. Air velocity range 7.5 to 3,000 m/min (750 m/min with velgrid). 100 point memory with sum and average. Accessories include pitot tube and a 16 point velgrid for face velocity work including exhaust hoods, clean room outlets, and large filters or coils.

Testo 445 Vane Anemometer with 16mm VaneTES,445 (5842) AUMicro-vane probe. Simultaneous digital display of air velocity and temperature, with continuous-update, max, min & mean functions. Volume-flow option with entry of duct dimensions. Telescope mounted metal probe, vane 16mmØ. Operating range 0.4 to 60m/s, accuracy ±0.2 m/s, ±1%mv up to 40m/s. Temperature range -30 to 140ºC for short-term measurements. Selectable site-locations, and 3,000 point internal memory for manual saving or automatic data logging. Battery powered.

TSI 8324 VelociCalc 100mm Vane Anemometer with Volume Display

TSI,8324 (5839) AUVane anemometer with 100mm head, supplied with handle and 900 mm articulated telescopic extension. Velocity measurement range 0.25 to 30m/s ±1%;

temperature measurement range 0 to 80ºC ±0.5 ºC. Volume display range 0 to 4.36 x 106m3/h with input for circular or rectangular duct dimensions. Variable time-constant; sample statistics average, max and min; and “sweep” mode for extended continuous sampling. Internal memory for single point measurements or time-based data logging, for up to 2849 samples and 1,000 test IDs, with serial interface, cable and software for data download. Direct data acquisition [polling] from PC terminal modes. Battery powered with auto-power-off, and optional AC adaptor.

TSI 8373 Balometer With LoggingTSI,8373 (5826) AU/MYFlow range 15 to 1,000l/s (54 to 3,600m3/h); accuracy ±5% [to ±2.4l/s]. Operating temperature range 0 to 60°C. Includes 5 hood kit & hard case. Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm, 305 x 1,525mm & 915 x 915mm.

TSI 8375 Accubalance Modular Air Balancing ToolTSI,8375 (5827) AUBalometer with detachable micromanometer (TSI 8710) for air balancing applications. With 610 x 610mm air capture hood for measurements in the range 42 to 4250m3/h with automatic compensation for barometric pressure and air temperature, 45cm pitot probe [range 0.13 to 41m/s], 16-point velocity matrix probe [0.13-13m/s] and static pressure probes [differential pressure range ±3735Pa with safe limit 37kPa, absolute pressure range 47 to 135kPa. Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit LCD display for single or statistical readings with min, max and average of up to 1,000 values of each measured parameter. Manual result storage or automatic data logging up to 1,000 time/date stamped readings. RS232 port for data transfer to PC or serial printer, with cable and “LogDat” download software. Rechargeable with approx 12h operation, or AC adaptor.

Air Conditioning & Air Flow

Air Conditioning & Air Flow cont’d.

Construction, Building Services & Survey www.techrentals.com.au

Page 61: normas quipment-solutions-guide

59

Air Conditioning & Air Flow cont’d.TSI 8386A VelociCalc Air Conditioning Efficiency MeterTSI,8386A (5848) AUPortable efficiency measurement system for HVAC and related

work, with hot wire anemometer, static and differential pressure, temperature and humidity measurement with heat flow efficiency calculation. Velocity (hot wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3. Wet bulb temperature 5 to 60°C. Relative humidity 0 to 95%RH, accuracy ±3%. Dewpoint -15 to 49°C. Static/differential pressure -1,245 to 3,735Pa, accuracy ±1%. Probe length 100cm, tip diameter 7mm, base diameter 10mm. Includes data logging and printing. Battery operated.

TSI 8705 DP-CALC Differential Micro-ManometerTSI,8705 (5815) AUDifferential micro-manometer measuring differential pressure, velocity, average, volumetric flow, maximum and minimum. With static pressure calculations, density correction and K factor. Pressure range -1245 to 3735Pa. Velocity range 1.27 to 78.5m/s. Supplied with 200 to 980mm telescopic pitot tube. Datalogging (1,000 point) with RS232C interface and software. Battery powered.

TSI 8710 DP-CALC Differential Micro-ManometerTSI,8710 (5813) AUMicro-manometer for static or differential pressure, velocity, volumetric flow, atmospheric pressure and temperature. With statistical analysis, density correction, K factor and automatic actual/standard flow calculation.

Differential pressure range ±3735Pa. Velocity display to 41m/s (range depends on probe). Supplied with static tip, pitot tube, velocity matrix and temperature probe. Datalogging (1,000 point) with RS232C interface and software. Rechargeable cells or AC adaptor.

TSI 9535 Anemometer with Logging CapabilityTSI,9535 (5845) AUIncludes data captured download software and USB cable. Logs

velocity and temperature. Will calculate flow rates. 0 to 30m/s Accuracy 3% of reading or ±015m/sec whichever is greater. Temperature range -18 to 93°C ±0.3°C. Runs 4 x AA batteries.

TSI 9555 Multi-Function Ventilation MeterTSI,9555 MYPortable, hand held, multi-function ventilation meter. Comes with differential pressure and 966 articulate probe which measures air velocity, temperature and humidity. Calculations include air flow, heat flow, turbulence, wet bulb and dew point temperature. Velocity measurement: Range: 0 to 9,999 ft/min (0 to 50 m/s) , Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s), Resolution: 1 ft/min (0.01 m/s). Temperature measurement: Range: 14 to 140°F (-10 to 60°C), Accuracy: ±0.5°F (±0.3°C), Resolution: 0.1°F (0.1°C). Humidity measurement: Range: 0 to 95% RH, Accuracy: ±3% RH, Resolution: 0.1% RH.

TSI 9565A VelociCalc Air Conditioning Efficiency MeterTSI,9565A (5849) AUPortable efficiency measurement system for HVAC and related

work, with hot wire anemometer, static and differential pressure, temperature and humidity measurement with heat flow efficiency calculation. Velocity (hot wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3. Wet bulb temperature 5 to 60°C. Relative humidity 0~95%RH, accuracy ±3%. Dewpoint -15 to 49°C. Static/differential pressure -3,735 to 3,735Pa, accuracy ±1%. Probe length 1m, tip diameter 7mm, base diameter 10mm. Includes data logging and printing. Battery operated. USB & Bluetooth download.

Air Conditioning & Air Flow cont’d.Vaisala WAA151 Wind Speed/Direction TransducerVAI,WAA151 (5886) AURange 0.4 to 75m/s. Current output with selectable ranges including 4 to 20mA & 0 to 20mA. Requires indicator module such as DE,DT600 datalogger for indication of wind speed and direction.

Air Conditioner Valve Balancing See also Data Loggers: Testo Temperature & Humidity Loggers on page 48

Tour & Anderson Scope Balancing Meter 1000kpaTA,CBI MY Digital pressure balancing instrument with LCD display.

For cooling water valve balancing in air conditioning plants and similar applications. Firmware revision 3A. Includes facility for entry of Kv value to allow balancing of all hydronic valve types. Differential pressure range -0.5 to 20.5m water gauge at a total pressure of less than 200m. Resolution 0.001m. Flow resolution 0.001l/s. Battery operated.

Tour & Anderson Scope Balancing Meter 1000kpaTA,SCOPE (5801) AUDigital flow balancing instrument with color display. For cooling water valve balancing in air conditioning plants and similar applications. Includes facility for entry of Kv value to allow balancing of all hydronic valve types. Differential pressure range -0.5 to 20.5m water gauge at a total pressure of less than 200m. Resolution 0.001m. Flow resolution 0.001l/s. Battery operated.

TSI TA465A Multi-Function Ventilation Meter

TSI,TA465A MYPortable, hand held, Multi-Function Ventilation Test Instruments. It comes with differential pressure. It also comes with the 966 articulate probe which measures air velocity, temperature and humidity. Calculations include air flow, heat flow, turbulence, wet bulb and dew point

temperature. Velocity Measurement Range: 0 to 9,999 ft/min (0 to 50 m/s) Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s) Resolution: 1 ft/min (0.01 m/s) Temperature Measurement Range: 14 to 140°F (-10 to 60°C) Accuracy: ±0.5°F (±0.3°C) Resolution: 0.1°F (0.1°C) Humidity Measurement Range: 0 to 95% RH Accuracy: ±3% RH Resolution: 0.1% RH.

Concrete Testing Equipment See also Endoscopes, Borescopes & Visual Inspection on page 41 See also Ground Penetrating Radars on page 61 See also Pipeline & Cavity Inspection on page 61-62

Elcometer 331-B Basic Cover MeterELC,331-B (4924) AU/MYDisplays depth and orientation of the reo bars. Deep search head supplied. 40mm diameter bar depth 35 to 180mm depth, 8mm diameter bar depth 25 to 160mm depth. Rechargeable battery allows 32h of continuous operation (20h with backlight).

Construction, Building Services & Surveywww.techrentals.com.au

Page 62: normas quipment-solutions-guide

60

Concrete Testing Equipment cont’d. Elcometer 331-SH Cover Meter with Half Cell MeasurementELC,331-SH (4919) AUDisplays the depth and orientation of the reo bars. Standard search head. 40mm diameter bar depth 15 to 95mm. 8mm diameter bard depth 8 to 70mm. Rechargeable battery allows 32h of continuous operation (20h with backlight). Autosizing of bars or orthogonal measuring of bar sizes. Internal storage of readings of depth of cover in batches which can be downloaded to PC with supplied software. XP and Vista supported.

Hilti PS20 Rebar, Copper Pipe & Electrical Cable LocatorHIL,PS20 (4920) AULocalise and position of reinforcement, (rebars) copper, aluminium pipes and unshielded live electric cables. Depth range for detection of rebars 0 to 100mm, for copper & aluminium pipes 60mm, rebar diameter 8 to 36mm, depth detection accuracy 10 to 30mm ±2mm, above 30-60mm

± 2mm ±10% depth, above 60 to 80mm ±5mm ±10% depth, based on 12mm rebars. Detection of copper & aluminium pipes based on 10 to 30mmØ, only detection with depth of 0 to 60mm, no depth reading, same for live electric cables, cannot detect live cables in metal conduit or shielded cables.

Hilti PS200 Ferroscan SystemHIL,PS200 FERROSCAN (4921) AUPortable, quick and easy to

use for detecting rebar and other ferrous objects in concrete structures. Provides accurate on-site rebar location, depth and diameter with the PS 200M monitor. Scans can be evaluated on the monitor or transferred to a PC or laptop for further

evaluation and report generation. Portable wireless operation, easy integrated LCD display makes setting up the scan easy while providing information over the scan process. Fast data download via infra red beam from scanner to monitor. Convenient Scanner stores up to 9 image scans and 30m of Quickscans.

Hilti PS38 MultidetectorHIL,PS38 (4918) AU

Designed to detect objects such as ferrous metals (rebars), non-ferrous metals (copper and aluminium), wood beams, plastic pipes, electric cables in dry materials. Detects at depth up 120mm. Location accuracy ±15mm. Depth accuracy ±5mm. Minimum distance between two objects 40mm.

Hilti PS1000 X-scan Concrete GPR SystemHIL,PS1000 (4922) AUA GPR system with 3 transmitters and 5 receivers that has been designed to

provide a 3D image of the location of reinforcement bars and other metallic and non-metallic objects in concrete. Accuracy ±10mm. It will measure to a depth of 300mm.

Handy Search NJJ-95B Reinforced Concrete Radar

JRC,NJJ-95B (4923) AUGround Penetrating Radar (GPR) technology applied to the location of reinforcement in concrete. Unit will search to a depth of 300mm.

Display is very easy to interpret (scanned images). Scan information can be saved to a memory card for transfer to a PC. A 3D image of the slab can be generated using PC software. Can be used to detect voids in concrete and the concrete depth is easy to determine from the image. The location of non-metallic objects can also be determined.

Concrete Testing Equipment cont’d. Olson FTG Concrete Thickness Gauge

OLS,CTG (4929) AUConcrete thickness gauge utilising the impact Echo test method. Can measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m. This concrete thickness gauge is a battery operated handheld system for measuring the flaws and thickness of concrete

slabs, pavements, walls and other plate-like structures from one side. Up to 300 readings can be stored in the field before the memory is full. RS232 interface and transfer software supplied.

Proceq 2000-ND Digi Schmidt Test HammerPRO,2000-ND (4930) AUConcrete hardness tester (Schmidt hammer). Supplied complete with inbuilt graphical LCD for setting up and graphical display of results, up to 500 results can be stored. RS232 interface and software

supplied for down loading. Impact energy 2.207Nm. Engineering units of results in N/mm2, MPa, psi, kg/cm2. For concrete thickness greater than 100mm.

Proceq Profoscope Rebar Locator & Cover MeterPRO,PROFOSCOPE (4926) AURebar locator and covermeter. Short range measurements to 95mm ±3mm accuracy. Long range 185cm accuracy ± 4mm. The unit will determine the position of the rebars, the mid point between rebars, Concrete cover, estimation of bar diameter & the orientation of the rebar. Powered by 2 x AA batteries. Battery life 15h with backlight 55h without.

Proceq Resistivity MeterPRO,RESIPOD (4925) AUCan determine the likelihood of

corrosion and the corrosion rate in concrete. 0 to 1,000kΩ measurement range. USB interface, USB charging. Waterproof.

Proceq SilverSchmidt UN Concrete Test Hammer PRO,SIL-UN (4928) AURequires no corrections for angle of test, simple one button operation, datalogging

capability with USB download with detailed reporting capability. Impact energy 2.207Nm. Compressive strength range 10 to 170MPa. Battery Life >1,000 Impacts before recharging is required.

Protimeter Moisture Measurement SystemPRO,MMS-PLUS (4955) AUMoisture meter for detection of moisture in non conductive solid materials such as wood and masonry. Two measurement modes, search for qualitative measurements and measure mode for precise and localised moisture content. Supplied with pin type probes, deep wall probes, hygrometer probe and extension cord for RH, ambient temperature or dew point temperature. Hygrostick probe supplied for surface temperature measurement. Logging software and RS232 computer interface supplied.

See also Material Moisture Meters on page 62

Construction, Building Services & Survey www.techrentals.com.au

Page 63: normas quipment-solutions-guide

61

Underground Services Location See also Prospecting Metal Detectors on page 70

CScope CATXDSGV-KIT Cable and Pipe LocatorCSC,CATXDSGV-KIT (3730) AU

CSC,CATXDSGA-KIT MYIndustry standard locator used to determine the exact location of buried pipes and cables. Functions include; Power mode for detecting live imbalanced cables to a depth of 3m, Radio mode for detecting re-radiated radio signals to a depth of 2m and Generator mode for detecting conductors carrying the signal generated by

the C.Scope signal generator.

Vivax VLOCPRO Pipe and Cable Location SystemVIV,VLOCPRO (3740) AU

Pipe and Cable locator with intuitive menu system, colour display, peak, null, left/right

and orientation (compass) response to support your preference. Configured with 6 location frequencies, power and radio modes. 10 watt transmitter can apply the location signal by connection, induction and signal clamp. Depth detection up to 6 to 9 meters in broad-peak mode.

Utility Leak DetectionGutermann Aquascope 3 Leak LocatorGUT,AQUASCOPE3 (3820) AU Listens for the sound of a leak. Specific digital signal processing,

designed to remove electrical noise and provide the operator with only the sound of the leak. Includes both ground and hand probe microphones. The display indicates the level of the noise from the leak. That way you can determine when you are nearest to the leak i.e. when the level is at its highest, you are nearest to the leak.

Ultra Probe UP100KT Ultrasonic Leakage DetectorULT,UP100KT (3825) AUHand held pistol type with stainless steel sensor enclosure. Frequency reponse 20 to 100kHz, (centred at 28 to 42kHz), 10 segment LED

bargraph (red). Sensitivity 8 precision attenuation. Response time 300ms, operating temperature range 0 to 50°C. Kit includes contact stethoscope module with different wave guide extension rods for direct for use on pipes, bearing housings, steam traps, etc. Rubber focusing probes, head set, warble tone generator for determining leaks in seals of empty containers, etc.

Ground Penetrating Radar See also Concrete Testing Equipment on page 59-60

USRadar Ground Penetrating Radar SystemUSR,SEEK-SPR (3601) AUDesigned to locate buried objects. Typically used for the location of cables and pipe, detection of pipe and the detection of underground storage tanks. For targets as small as 5cm diameter and up to 4m depth.

Pipeline & Cavity Inspection See also Endoscopes Borescopes Visual Inspection on page 41

Aqua Snakeeye Video Inspection System AQU,SNAKEEYE3 (5166) AUHandheld video system for remote inspection work. Very

light and compact. Includes a 12.7cm TFT-LCD display and 3cm diameter camera including illumination. Various adapters are supplied for mounting the camera to: a) your hand b) a 45.7cm arm with 90 degree articulation, c) a 30m extension cable or d) an arm which extends from 1.6 to 3.6m. Includes memory card and will save images to card.

Archos AV 500 Mobile Digital Video Recorder - 100 GB ARC,AV500 (5188) AUUnique mobile digital video recorder offering direct TV recording and the best of video, photo and music on the go on a 4” colour screen, 100 GB hard drive. Easy setup pod for TV recording & video playback , control your VCR, cable or satellite receiver. Record directly to TV or make scheduled recordings, photo wallet & music player. Stores up to 400 hours of video, 250 movies or 1 million photos.

Testo Fibrescope 1.2m with Guide TubeTES,319 (5170) AUSupplied with guide tube, 45 degree mirror & magnetic tip. Number of pixels 6,000. Fibre-optic field of view 50°. Angle of field of view 45° ±5°. Min focus distance 15mm (focus). Max focus distance 150mm (light). Operating

and storage temperature: -20° to 60C. Working temperature/probe -20° to 80°C. Probe diameter 6.5mm. Probe length 1247 mm ±6. Max bending radius 50mm. Light source LED 2 point light. Probe resistance: probe tip water-proof up to handle short-term resistance to silicone oils, petrol and kerosene. Oils or petrol must be wiped off immediately after immersion. Battery type 3AA batteries. Battery life 4h. Note: the magnetic tip can be used to remove small magnetic objects.

Vivax Pipeline Camera Inspection System VIV,VCAM-60M (5155) AU

60 meter pipeline inspection system with self leveling camera (D33/SL, 41mm diameter) will record MPEG4 videos and provides a keyboard, titler and sound system to add up to 16 pages of text and an audio commentary. Can be uploaded via a USB interface to a computer allowing copies to be made or images to be captured for inclusion in reports. Camera includes a sonde with 512Hz, 640Hz and 33kHz modes. Submersion depth up to 1 bar (10m).

Vivax Pipeline Camera Inspection System VIV,VCAM-120M (5196) AU

120 meter pipeline inspection system with self leveling camera. Will record MPEG4 videos and provides a keyboard, titler and sound system to add up to 16 pages of text and an audio commentary. Can be uploaded via a USB interface to a computer allowing copies to be made or images to be captured for inclusion in reports. Camera includes a sonde with 512Hz, 640Hz and 33kHz modes.

Construction, Building Services & Surveywww.techrentals.com.au

Page 64: normas quipment-solutions-guide

62

Pipeline & Cavity Inspection cont’d.Wohler VIS2000Pro 30m x 51mm Colour Camera & Roller GuideWOH,VIS2000PRO (5164) AUSuitable for inspection of ventilation ducts, chimneys, chambers and flue gas systems, etc. Kit consists of colour display with a joystick to control camera. 30m push rod cable on a reel, with a non-waterproof, splash resistant (IP64 rated) 51mm diameter colour camera

with illumination. Accessories include a Roller Guide to allow the camera to be pushed down a pipe. Can save still images and video to a memory card. Video out function.

Wohler VIS340 Service Camera Visual Inspection System 30mWOH,VIS340-PT (5160) AU

WOH,VIS340 MYCompact colour video inspection system with 26mm forward facing and 40mm Pan Tilt colour cameras. Viewing angle 120°, waterproof according to IP68(3 bar-30m) and

IP67(2 bar-20m) respectively. Bright white LEDs on 30m of flexible push rod with metric markings. Battery powered 7” high resolution colour screen with removable monitor and SD video recording. Applications incl damage analysis in water/drainage/sewer pipes, inspection of hollow spaces, ventilation, machines, control panels, exhaust systems and production surveillance.

Material Moisture Meters See also Concrete Testing Equipment: PRO,MMS-PLUS on page 60

Protimeter SM Moisture MeterPRO,SM (4954) AUMoisture meter for survey work. Very good for determining wet points. Will provide % moisture content for timber. Subsequent accurate measurements can then be made.

Distance Measurement & Surveying See also Light Meters, UVA/B/C Measurement on page 68

ikeGPS Precision GPS and Laser Distance and Camera SystemIKE,300PRO (5301) AU

Intergrated precision GPS (1.5m), laser based range finder (300m), Precision compass, precision inclinometer and camera system. Used to geolocate and document. It can be used to remotely dimension cable and buildings, etc.

Construction, Building Services & Survey www.techrentals.com.au

REMOTE CONCRETE POUR TEMPERATURE SENSING AND SAMPLE CONTROL USING MODBUS

TechRentals have developed a simple solution for the monitoring of the concrete curing process that also provides ‘matched temperature’ control of the concrete pour samples. The benefits include a more accurate estimation of concrete strength and potential shortening of the period before additional construction can commence.

An application of the Modbus protocol has enabled the efficient implementation of concrete pour temperature remote monitoring and also control of the storage environment of concrete test. The system is sufficiently undemanding in installation for it to be supplied as a rental system however many users would find it practical to have it as a standard tool.

A dataTaker model DT80M logger is used to gather 30 channels of thermocouple data at the concrete pour and the data is linked to a second DT80M at a remote office location. The site data is monitored for obvious errors and faulty thermocouple data is automatically rejected. The office logger controls a thermal bath and maintains this as an accurate analogue of the site concrete pour temperature. Site samples are placed in the bath and thereby are maintained in closely matched conditions to those in the construction. The samples can

therefore be subjected to mechanical testing with a high degree of confidence. This together with the precise monitoring of the site curing process considerably increases the confidence in the state of the concrete. This allows for earlier formwork striking times with an earlier start to prestressing and consequently significant savings. This system is simple to implement with the baths currently in use.

The first implementation of the system was in a remote location in Queensland.

The dataTaker data loggers and associated hardware are available from TechRentals who also wrote the associated software. TechRentals sales engineers are always ready to offer advice on any aspect of test and measurement instrumentation selection and use.

Page 65: normas quipment-solutions-guide

63

Environmental Gas & Vapour MetersPersonal Gas & Vapour MonitorsAirborne Dust & Particle MetersAir Quality & Heat StressMoisture & Humidity MetersNoise & Sound AnalysersRadiation Monitoring & ProtectionFloor Slip TestersWater Quality, pH Meters & EletrochemLight Meters, UVA/B/C MeasurementWeather StationsEnvironmental Flow MetersLaboratory & Hand-held Microscopes Balances & Scales below 8kgChemical & Analytical - GeneralLaboratory Instruments, Spectroscopy

See also Combustion, Flue & Industrial Gas Analysers on page 50

Aeroqual 500L Portable Logging Ozone MonitorAER,500L (5958) AUPortable ozone monitor fitted with low concentration-range detection head. Operating range 0 to 0.5ppm ozone with display in ppm or mg/m3. Gas sensitive semiconductor [GSS] sensor for accurate low-level measurements, T90 response approximately 100s. Operation from mains power supply or battery pack (4h operation). Internal data logging for 8,000 points with software and cable for download to PC, or data logging direct to PC. Application for indoor air quality measurements.

Geotech Landfi ll Gas ExMonitorGEO,GEM5000 (5940) AUMeasures CH4, CO2, O2, CO & H2S.

Designed for spot measurements. Intrinsically safe and has a built in GPS system. It can also measure fl ow rates from bore holes and perform landfi ll gas energy calculations.

GasCheck 3000 Portable General-Purpose Leak DetectorION,GASCHECK3000 (5906) AUMicro thermal-conductivity sensor for high-sensitivity detection of gases with a thermal conductivity different to that of air, including helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups. Direct reading of leak rate in ml/sec with audio and visible signals. Detection limit for helium 2E-5ml/s. Battery Powered.

Ion Science Gascheck Helium, Butane & SF6 DetectorION,GASCHECKG3 (5907) AU/MYMicrothermal conductivity gas detector. Reading in cc/s, g/yr, mg/m3 or ppm. Detects most gases however particularly suited to ammonia, argon, butane, helium, hydrogen & SF6. Calibrated against Helium. Battery Life 40h. Sensitivity (cc/s) He 1x10-5, CH4 5x10-5, R12 5x10-5, Ar 1x10-4. Accuracy 5% of displayed

reading + 1 digit. Response 1s. Flow rate 2cc/min. Operating -20 to 60°C. Data logging, stores 10 readings.

Oldham MX21 Plus Gas Monitor for Sulphur Dioxide SO2OLD,MX21-SO2 (5927) AUPortable gas detector for personal, workplace or space monitoring of sulphur dioxide (SO2) in the range 0 to 30ppm. Operation in passive or pumped modes, with sampling tube and flexible probe. Data logging, with software included for download to serial printer or computer. Rolling storage of up to 48h data (at 1min intervals) in multiple groups. Rechargeable battery.

PetroSense PHA-100 Petroleum Hydrocarbons in Water Detector

PET,PHA-100 (5945) AUPortable hydrocarbon analyser for insitu realtime petrochemical contamination. Measures Total Petroleum Hydrocarbons (TPH) in water and water vapour. Uses a fibre optic chemical sensor (FOCS). Measures 0.1ppm xylene in water ad < 10ppm in vapour. Accuracy ±15% of readings. Response time <5sec. Certified to EPA Method 8020.

Photovac 2020 Portable PID VOC MonitorPHO,2020PRO (5950) AUPortable handheld VOC (Volatile Organic Compound) monitor with data logging. PID sensor (Photo-Ionisation Detector) fitted with 10.6eV lamp. Ranges 0.5~2000ppm humidity compensated. Downloadable data logging for 15,000 points with time, data and header. Intrinsically safe.

PPM 400 Portable Formaldehyde MeterPPM,FORM400 (5962) AUPortable Formaldehyde meter for measuring airborne formaldehyde in the workplace. Electrochemical sensor, with internal pump for rapid response. Operating range 0.05 to 10ppm with readout on 4 digit LCD display. Kit includes field calibration standard. Operates from 9V alkaline battery.

RAE Systems Minirae 2000 Portable PID RAE,MR2000 (5950) AUPortable handheld VOC (Volatile Organic

Compound) monitor with data logging. 3-D PID sensor (Photo-Ionisation Detector) fitted with 10.6eV lamp. Ranges 0 to 999ppm (resolution 0.1) or 100 to 10,000ppm (resolution 1) VOC expressed as isobutylene. Built-in correction factors for 102 compounds from a total standard library of 250. Integrated pump for local or remote (30m) sampling, with stall protection against liquid ingress. Downloadable data logging for 1,500 points with time, data and header. Intrinsically safe. Up to 10h operation with rechargeable (NiMH) or alkaline batteries.

Environmental Gas & Vapour Meters

Environmental Gas & Vapour Meterscont’d.

Environmental, OHS, Chemical & Laboratorywww.techrentals.com.au

Page 66: normas quipment-solutions-guide

64

Environmental Gas & Vapour Meterscont’d.

Minirae 3000 Advance Handheld VOC Monitor RAE,MR3000 MYHandheld volatile organic compound (VOC) detector. Photoionization Detector’s (PID) extended range of 0 to 15,000 ppm, ideal For applications from industrial hygiene, to leak and HazMat detection. RF modem allows real-time data transmissions with a base controller located up to 500 feet (or two-miles with optional RAELink3 portable modem) away from the MiniRAE 3000 detector. A personal computer can be used as the base station for a Mini-RAE 3000 system.

RH Systems 973-SF6 Analyser RH,973-SF6 (5910) AU

Measures the purity of SF6 gas. Uses a fast acting mirror system to measure humidity. Displays direct % purity. Includes a gas recovery system.

Includes built in test for instant verification of the system accuracy. Dew Point measurement -55 to 20°C, pressure 0.1~30 Bar. Accuracy ±0.5° dew point. Gas coupling is done via a quick connect fitting.

Wika GA-15 SF6 Leak Detector WIK,GA-15 (5909) AUA fast response SF6 leak detector which will detect concentrations of SF6 down to 3ppmv. Only detects SF6 and is unaffected by moisture and wind.

Personal Gas & Vapour MonitorsBW Bump & Logging Download for BW,MICROCLIPBW,BUMP (5938) AU/MY

Automatic calibration testing and data management system for the BW microclip gas detection equipment. Carries out fully automatic “hands-free” calibration and functional bump test. It also enables data collected during operation of the BW microclip to be downloaded.

BW Gas Alert Micro Clip Confined Space 4 Gas DetectorBW,MICROCLIP (5937) AU/MYContinuous LCD shows real time gas concentrations. Simple 1 button operation. Measures:- H2S 0 to 100ppm (1ppm resolution), CO 0 to 500ppm (1ppm resolution), O2 0 to 30% (0.1% resolution) and Combustible gases

0 to 100% LEL (1% resolution), 0 to 5% v/v (0.1% resolution). Alarms: visual, vibrating and audible (95dB), Low, High, STEL, TWA and OL (over limit). Lithium polymer battery life 12hrs (typical) recharge time <3hrs.

BW Sampling Pump for BW,MICROCLIPBW,GA-SPAK (5939) AU/MYMotorised sampling pump that provides 300ml/min for remote sampling up to 18m away. Runs continuously for 30hrs on batteries. Includes 3m sampling hose. Includes built in water traps and particulate filter.

Airborne Dust & Particle MetersAbacus 301 Hand-held Airborne Particle CounterABA,301 (5878) AUPortable particle measuring system typically used in clean room applications. Four fixed size channels 0.3, 0.5, 1.0 & 5.0 micron. Count data automatically stored in a 500 sample memory which can be downloaded to a PC. Selectable sample time. Includes zero count filter for checking backgrounds. When used with included software will check clean rooms to ISO 14644 and BS5295 requirements. Battery operated.

TSI 8520 DustTrak Airborne Particle MonitorTSI,8520 (5872) AUPortable aerosol monitor. Laser photometer with 90ºC scattering

detection, Range: 0.001 to 100mg/m3 [Calibrated for A1 test dust, ISO 121203-1], resolution: 1% of reading or 0.001mg/m3; particle size range: 0.1 to 10μm. Internal pump flow rate 1.4 to 2.4l/min (1.7 nominal). Data logging 30,000 data points (21d@1min), log interval: 1s to 1h. RS232C interface and software included. Battery operated.

TSI 8520-1 Environmental Enclosure for DustTrakTSI,8520-1 (5874) AUWeatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case with tripod mount, fitted with sample inlet and water trap. Includes extended-life battery pack and charger/adaptor.

TSI 8525 P-Trak Ultrafine Particle CounterTSI,8525 (5877) AURange 0.01 to 5 x 105 particles/cm3. Particle size range 0.02 to greater than 1micron. Includes PC software and cable. Suitable for detection of ultrafine particles associated with pollutants. Battery powered (8h operation using alkaline batteries).

TSI 8530 Aerosol Monitor and LoggerTSI,8530 (5873) AU/MY

Portable dust and particle monitor, light scatter photometer. Measure concentrations corresponding to PM1, PM2.5 & PM10. Aerosol concentrations 0.001 to 150mg/m3. Used for industrial/occupational hygiene surveys, indoor air quality monitoring, outdoor environmental monitoring, baseline trending and screening, etc.

TSI Environmental Enclosure for the TSI,8530TSI,8530-ENC (5875) AU/MYEnclosure to suit the TSI,8530. Includes two additional batteries and charger. Includes waterproof enclosure and heat shield and enclosure stand.

TSI Environmental Enclosure for the TSI,8530 Dusttrak IITSI,8530-ENC-S (5876) AUEnclosure to suit the TSI,8530. Includes two additional batteries and charger. Includes waterproof enclosure.

TSI 8533 Aerosol Monitor and LoggerTSI,8533 (5870) AUPortable dust and particle monitor, light scatter photometer.

Measure concentrations corresponding to PM1, PM2.5 and PM10. Aerosol concentrations .001 to 150mg/m3. Used for industrial/occupational hygiene surveys, indoor air quality monitoring, outdoor environmental monitoring, baseline trending and screening etc. Will size particles in three sizes PM1, PM2.5 and PM10.

Environmental, OHS, Chemical & Laboratory www.techrentals.com.au

Page 67: normas quipment-solutions-guide

65

Airborne Dust & Particle Meters cont’d.TSI AM510 Personal Aerosol Monitor; CSA & ATEX IS approvalsTSI,AM510 (5871) AUWearable dust monitor. Built in Impator allows you to chose either ‘none’, 1, 2.5 or 10μm particle sizes. Datalogs TWA in the range of particle concentrations from .001 to 20mg/m3 Runs 9.2hrs on rechargeable NiMH batteries. USB download capability. CSA & ATEX IS approvals.

Air Quality & Heat Stress Casella Microtherm WBGT Area Heat Stress Monitor CAS,MICROTHERM (5868) AUPortable area heat stress WBGT monitor with real-time graphical display. Measures heat stress potential [WBGT index] according to ISO7243. PRTD sensors with internal calibration-reference for wet-bulb, dry-bulb and globe temperatures.

Large LCD display for numerical or graphical indication of temperatures and processed values for WBGT [indoor/outdoor plus TWA], relative humidity and dewpoint. Simple keypad/menu setup. Data logging for up to 32 separate runs and 49,100 records, with interval 30s to 1h. RS232C port with included PC software for download and reporting or realtime display. Low water-level warning, and settable audible/visible WBGT alarm. Handheld, free-standing or tripod-mount. Battery operated.

Testo 635-2 Humidity, Temperature & Dewpoint MeterTES,635-2 (5859) AUPortable humidity meter fitted with robust stainless probe with sintered filter-cap for general or duct measurements to 120ºC, and fast-action K-type surface temperature probe. Displays relative humidity, absolute humidity, dew point, degree of humidity, enthalpy, temperature, and differential temperature (dewpoint to surface). Operating range 2 to 98%RH (±2%). Air temperature -20 to 120ºC (±0.2/0.5). Surface temperature -60 to 300ºC (±0.1). Internal memory for 10,000 values with USB interface, cable and software for download and presentation. Battery operated.

Testo 645 Humidity & Dewpoint MeterTES,645-1 (5858) AUPortable humidity meter fitted with robust stainless probe for ambient work or duct measurements to 120°C. Displays relative humidity, absolute humidity, dew point, degree of humidity, enthalpy and temperature. Operating range 2 to 98%RH [±2%], -20 to 120°C [±0.4/0.5]. Battery operated.

TSI Q-TRAK IAQ Monitor CO2, CO Temperature & Humidity LoggerTSI,7565 (5861) AUMeasures CO2 0 to 5,000ppm ±3%, temperature 0 to 60ºC ±0.6ºC, humidity 0 to 95% ±3%, CO 0 to 500ppm ±3% and barometric pressure 517.15 to 930.87mmHg ±2%. Calculates dew point, wet bulb and percent outside air. Displays 5 measurements simultaneously. User selectable logging interval and start stop times. Stores 39 days data at 1min intervals 56,035 data points. This unit also has external thermocouple measurements.

Air Quality & Heat Stress cont’d.TSI Q-Trak plus Indoor Air Quality Monitor with Logging TSI,8554 (5860) AU/MYIndoor air quality (IAQ) monitor for temperature and humidity measurements, CO and CO2 concentrations. Humidity range 0 to 95%, temperature range 0 to 50°C. Electrochemical cell for CO 0 to 500ppm. NDIR cell for CO2 0 to 5,000ppm. Data logging for 48,671 data points with interval adjustable 1s to 1h. Fitted with RS232 interface, and software included for download, storage and reporting. Battery or mains operation with AC adaptor.

Moisture & Humidity Meters GE Panametrics PM880 Industrial Moisture AnalyserPAN,PM880 (5911) AU

Intrinsically safe moisture analyser for compressed air systems, non-corrosive gases & hydrocarbons such as natural gas (IS certification to ATEX and CSA). Displays dew point, moisture concentration, pressure & temperature. Dew point calibrated measurement range -80 to 20°C with data to -110°C. Pressure range 7 to 69 Bar limited

by sensor, gauge and safety-valve (operating range from 5μHg). Temperature range -30 to 70°C. Gas flow operating range from static to 10,000cm/s velocity. Supplied with compact sample system with gauge, safety-valve, sampling valves and fittings (¼” Swagelok). Data logging of up to 100K moisture points, with infrared port and software for download. Battery powered only (15-24h operation) with second battery and charger (note charger is not IS).

Noise & Sound Analysers See also Vibration Analysis on page 55-56

ARL EL-316 Environmental Noise Logger Type 1ARL,EL-316 (5695) AU

Environmental noise logger with display for field-reading of summary results. Portable, self-contained and weatherproof. Type 1 performance, continuous 90dB dynamic range, fast response, frequency weightings A and C. Monitors environmental noise continuously for up to 3 weeks, calculates and stores over 7,500 sets of Ln indices. PC required to set up system and download data using software supplied. Set up also possible from front-panel.

ARL NGARA Environmental Noise LoggerARL,NGARA (5690) AUCan be configured to record all sound continuously so noise data can be post processed. It can prove logged data, WAV data & alarm/triggered details. Type 1 microphone provided.

Environmental, OHS, Chemical & Laboratorywww.techrentals.com.au

Save your time and reduce your real costs. Find out all about our Confi guration and Download solutions on page 37.

Page 68: normas quipment-solutions-guide

66

Noise & Sound Analysers cont’d.B&K 2238E Type 1 Integrating SLM Enhanced Software & LoggingBK,2238E-NATA (5678) AU

Type 1 (class 1) Integrating sound level meter with additional functions including enhanced software, frequency analysis and data logging. Standard routines include functions for workplace measurements and general sound-level checks; enhanced software (firmware) offers additional measurements and statistics for assessment of environmental noise problems; frequency analysis automates measurements in the 9 single octave bands and 29 1/3 octave bands. Supplied with field calibrator. Compatible with BK,7815 Noise Explorer Environmental software for download, data analysis and display.

B&K 2239A Type 1 Sound Level Meter NATA CertificationBK,2239A-NATA (5667) AUType 1 (class 1) integrating sound level meter with backlit LCD

display, NATA certification. Simultaneous RMS (A,C) & peak (C) detection with independent frequency weightings. Measuring range 30 to 140dB. Time weightings fast, slow and impulse. Parameters Leq, MaxP, MaxL, MinL, Peak, SPL and Inst. Memory for 40 data records with realtime clock. Serial port for data download. Calibrator included. Operates with 4 x AA alkaline batteries.

B&K 4448 Badge Dose Meter IS Kit of 3 BK,4448-IS-3KIT (5680) AUKit of 3 Intrinsically safe noise dose meters. The kit includes a

NATA calibrated 4231 Type 1 calibrator. These are badge type Dose Meters, shoulder mounted, cable free and simultaneously measure all parameters required by noise at work standards. Simple two button operation. Rechargeable battery provides several working days of measurement.

Digital Audio Test Set comprising of NTI Digirator & NTI DigilyserNTI,NT-DAS (5684) AUAudio Excel Line for digital audio signals. System including the Digilyzer and Digirator for producing digital audio signals and analysing those digital audio signals up to and including 5.1 surround sound. Up to 192kHz 24bit, AES3,S/PDIF, TOSLINK & ADAT. ync input (AES3, Word

Clock, Video). Supports Dolby Digial, E, PL II, DTS. Channel transparency check. Channel delay measurement.

NTI XL2+M2210 Sound Level MeterNTI,XL2+M2210 MYSound Level Meter comes with Class 1 microphone, acoustical analyser options and audio analyser options. Applications in sound installations, live sound, studio, broadcast and environmental noise measurements. Logging all data or subsets in selectable intervals. Recording of wav-files (ADPCM), a new wav-file starts every 12 hours (max. wav-file size 512 MB). Real time analyzer with frequency

resolution: 1/3 octave, 1/1 octave, wide band and frequency range: 6.3Hz to 20kHz. Frequency weighting: A, C, Z. USB interface with PC analysis tool.

Quest 2400 Type 2 Sound Level MeterQUE,2400 (5660) AUType 2 sound level meter with LCD display for sound pressure level [SPL] or maximum level [MAX]. Frequency weightings A and C, time weightings Fast and Slow. Ranges 30 to 140dBA and 40 to 140dBC with overload indication. AC and DC outputs. Battery powered.

Noise & Sound Analysers cont’d.Rion NL-04 Sound Level MeterRIO,NL-04 MYMeets IEC type 2. Five measurement functions: Lp(SPL), Leq, LAE, Lmax & Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. Built-in RS232C interface for computer communication. 70dB dynamic range (digital display), 27 to 130dB (A) measuring range. Wide range of time settings for Leq, LAE, Lmax & Lx; 10s, 1, 5, 10, 15, 30min, 1, 8, 24h & manual time setting (up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1dB resolution, updated every second, plus 60dB analogue display display 1dB resolution showing the instantaneous value. Memory battery back-up. AC & DC signal o/p for level expanding system by optional filters, memory card & others.

Rion NL-32 SLM with RTA & NATA CertificationRIO,NL-32RTA-NATA (5674) AURIO,NL-32RTA MYPrecision integrating sound level meter to IEC type 1 (class 1) specification, with NATA calibration. Fitted with internal Compact Flash Card reader and supplied with NC-74 field calibrator. Frequency range 20 to 20,000Hz with weightings A, C, and flat. Time weightings fast, slow and impulse. Measurement range (A) 28 to 138dB. Broadband measurement functions Lp (SPL), Leq, Lmax/min, Lae, Lx, and selectable auxiliary functions

with manual or auto storage [logging]. Measurement time (Leq) from 10s to 200h. Inbuilt memory for up to 100 data sets, or to limit of fitted CF card using manual or auto storage. AC or DC outputs, RS232C interface and cable CC-93 for serial printer. Supplied with NX-22RT card for real time 1/1 and 1/3 octave analysis and display, for measurement functions Lp, Leq, LE, Lmax and display of AP (all-pass) AP(A) and 1/1 or 1/3 octave values as selected, with manual data storage only to NX-22RT card. Download of card-data to PC requires flashcard reader. Alkaline batteries (24h operation) or AC adaptor.

Rion NL52EX SLM with NX42RT Octave and 1/3 AnalyserRIO,NL52EX-NX42RT (5670) AUType 1 Sound Level Meter, including the Octave and 1/3 Octave measuement option NX42RT. This meter can be used to check NC levels for compliance checking. The instrument includes a NATA calibrated calibrator. All data is save to an SD card.

Radiation Monitoring & Protection See also E & H Field Strength Meters on page 11-12

Fluke 481 Radiation Survey Meter FLU,481 (5580) AUProvides exposure measurements in mR/hr to 50R/h (0.55v/hr). Detects skin-dose, deep-dose and X-ray radiation. Measures dose & dose rate.

HPI Cypher 5000 Digital Radiation Alert Monitor HPI,CYPHER5000 (5583) AUAlpha, Beta, Gamma and X-ray radiation monitor. Meter, LED, audible indication and detachable probe. Range 0.1 to 1,000,000 CPM; Accuracy 1% or 2 digits.

Narda 8217 Microwave Oven Survey Meter NAR,8217 (5553) AUFor oven power measurement complete with beaker and thermometer. Calibration frequency 2.45GHz. Measurement range 0.5 to 10mW/cm2. Battery operated.

Environmental, OHS, Chemical & Laboratory www.techrentals.com.au

Page 69: normas quipment-solutions-guide

67

Radiation Monitoring & Protection cont’d.

Narda RadMan Personal RF Field Radiation MonitorNAR,RADMAN (5557) AUPersonal monitor and leakage detector for high frequency electromagnetic fields. Simultaneous E and H field measurements with audible and visual alarms. Frequency range H field 27MHz to 1GHz; E field 1MHz to 40GHz. Operation as personal monitor with compensation for human body absorption, or with isotropic detection for RF leakage sensing and simple four-level measurement using LED indicators. Battery powered. Battery life over 200h.

Floor Slip TestersSevern Model Tortus II Floor Slip TesterSEV,TORTUSII (5505) AUFloor friction tester. Measures and records the dynamic coefficient of friction. Applications in assessing floor safety, evaluating cleaning methods

and maintenance procedures, accident investigation, etc. Meets the draft requirements of international, Australian and New Zealand standards.

Water Quality, pH Meters & Electrochem

Hydrolab Minisonde 5 Multiprobe Water LoggerHYD,MS5 (6020) AU

Miniosonde 5 multiprobe water/borehole logger, including ‘Surveyor’ data collection system with GPS. Includes sensors for Dissolved Oxygen (HACH LDO), Conductivity, pH, Redox (ORP), Turbidity (Self-Cleaning), Temperature, Depth (0 to 25m) and GPS position. Includes the surveyor data aquisition system so no laptop is needed for download or data collection. Includes a 25m cable.

ISCO 6700 Series Water SamplerISCO,6712 (6057) AUAdvanced water sampler for fully programmed collection. Samples are collected in up to 24 disposable plastic containers based on time, flow, and/or parameter set points. Fitted with NEMA 4X,6 (IP67) sealed controller featuring an exclusive, built-in pump.

OTT KL010-150 Ground-water Depth Measurement Contact Gauge 150mOTT,KL010-150 (6065) AUContact gauge for portable depth to water measurement. Used for wells, observation pipes, bore holes and control pumping tests. 150m depth of tape. as soon as the probe touches the water surface an acoustic signal beeps and the lamp on the instrument lights up. The depth is read from the measuring tape in meters.

Water Quality, pH Meters & Electrochem cont’d.

TPS 90FL-T Water Quality MeterTPS,90FL-T (6028) AUField meter and logger for water

quality measurements. Configured with independent probes for pH, conductivity/salinity[TDS] temperature, dissolved oxygen[DO] and turbidity. Cables 5m with probe holder and safety harness. LCD display readout with simultaneous display of all measurements.

Manual, “notepad” storage or automated data logging for up to 1,808 sets of readings by time and date. RS232C interface, with WinTPS software included. Supplied with rechargeable battery, and clip-lead for operation from a 12V source such as a car-battery.

TPS WP-80 pH and Temperature MeterTPS,WP-80 (6003) AU

Portable hand-held meter for pH, mV and temperature. Supplied with combination pH electrode and separate temperature sensor on 1m cables. Operating ranges 0 to 14pH and -10 to 120ºC (automatic sensor recognition with

auto pH correction 0 to 100ºC). Case water resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display. Auto storage of time and date of last calibration for GLP. Memory for 2400 readings of data, time and date, for Notepad results collection, or for AutoLog with logging intervals between 1s and 90h. Fitted with RS232C interface and supplied with download-software, charger and solutions. Rechargeable NiMH battery gives up to 50h operation.

TPS WP-80 pH and Temperature Meter for Testing MeatTPS,WP-80M (6002) AU

Portable hand-held meter for pH, mV and temperature. The instrument is capable of applying Bendalls equation to the pH reading for Meat Standards Australia grading requirements. Supplied with combination pH electrode and separate temperature sensor on 1m cables.

Operating ranges 0~14pH and -10~120ºC [automatic sensor recognition with auto pH correction 0~100ºC]. Case water resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display. Auto storage of time and date of last calibration for GLP. Memory for 2400 readings of data, time and date, for Notepad results collection, or for AutoLog with logging intervals between 1s and 90h. Fitted with RS232C interface and supplied with download-software, charger and solutions. Rechargeable NiMH battery gives up to 50h operation.

TPS WP-82 Dissolved Oxygen MeterTPS,WP-82 (6009) AU

Portable hand-held dissolved oxygen and temperature meter. Operating ranges 0 to 20ppm, 0 to 240% saturation, 0 to 45% gaseous and ppm with salinity correction. temperature range -10 to 120°C. Case water resistant to IP67, connectors to IP65, with 3m detachable cable and ED1 electrode. Menu driven, with alphanumeric display.

Auto storage of time and date of last calibration for GLP. RS232C interface, and memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied with download-software, charger and solutions.

Environmental, OHS, Chemical & Laboratorywww.techrentals.com.au

Watch a YouTube playlist on water quality testinghttp://youtube.com/techrentals

Page 70: normas quipment-solutions-guide

68

Water Quality, pH Meters & Electrochem cont’d.

TPS WP-84 Conductivity Salinity Temperature MeterTPS,WP-84 (6014) AU

Portable hand-held meter for conductivity, TDS (Total Dissolved Solids) and temperature. Automatic range selection with 5 ranges. Case water resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display for full-text prompting. Storage of time and date of last calibration for

GLP. Memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied with sensor (k=1), charger and solutions.

TPS WP-88 Turbidity & Temperature Meter with 8m Cable

TPS,WP-88 (6031) AUPortable hand-held turbidity and temperature meter for field or laboratory use. Sensor probe diameter 45mm, with 8m cable. Turbidity ranging 0.1 to 200/2,000NTU ±1NTU with autoselection. Temperature compensation and sensor

range 0 to 60ºC ±0.1ºC. Case water resistant to IP67, connectors to IP65, with detachable cable and sensor. Menu driven, with alphanumeric display. Auto storage of time, date and results of last calibration for GLP. RS232C interface, and memory for 150 readings of data, time and date, for Notepad results collection, or for AutoLog results collection with logging intervals between 1min and 24h. Rechargeable NiMH battery gives up to 50h operation. Supplied with download-software, charger and calibration solutions.

Van Essen DI502 Mini-Diver Borehole Level Logger & Barometer 20mVAN,DI502 (6061) AUMini-diver borehole level logger 20m, 1cm accuracy. Kit includes barometric logger for atmospheric pressure compensation. Will also log temperature. Temperature range -20 to 80ºC. Accuracy 0.1ºC. Size 22 x

90mm. Stores 24,000 measurements per parameter. Stainless steel housing barometric (l/c) logger for compensation. 10 year battery life.

Light Meters, UVA/B/C Measurement

Hioki 3423 Lux HiTester Digital Illuminance MeterHIO,3423 (5602) AU/MYManual switching and autoranging. LCD display with 3½ digits (“1999”) for five measuring ranges to 20/200/2,000lx in 1-count steps, 20,000lx in 10-count steps and

200,000lx in 100-count steps with accuracy ±4%. Response time in autorange mode 5s (2s in manual range mode). Autozero, hold and backlight function with delay for taking readings in low light. Input for AC power adaptor, connecting-cable to allow separation of sensor unit and meter, and 200mVDC analogue output with cable. Battery powered.

Light Meters, UVA/B/C Measurement cont’d.

ILI 1400ABC Radiometer for UV MeasurementsILI,1400ABC (5614) AUInternational Light model 1400 radiometer with backlit LCD display, autozero and autoranging. Continuous reading with hold function, or integrated “dose” measurement up to 24h. Smart

detectors with storage of units and detector-calibration data. Analogue recorder output. Mains adaptor or battery power. Supplied with three sensors: UV actinic hazard (UVC with B & A components matched to OSHA requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVB + A (total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2. UVB, range 1.54e-6 to 1.54e-2 W/cm2.

Minolta CL-200 Chroma Meter for Illuminance & Colour Measurement MIN,CL-200 (5610) AUKonica Minolta model CL-200 portable colour meter. LCD display for illuminance, tristimulus values, chromaticity, correlated colour temperature and colour difference. Illuminance range 0.1 to 99,990lx ±2%. Colour accuracy ±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface. Battery powered, or AC adaptor.

Topcon BM-9 Luminance MeterTOP,BM-9-2 (5611) AUPortable luminance meter with digital display. Field-of-view 5°, measurement acceptance angle 2°, with 10mm min spot diameter. Measuring distance 0.35m to infinity. Silicon photodiode sensor with automatic or manual range selection. Measurement range 0.01 to 199,900cd/m2 ±4% of reading. Built-in RS232C interface and analogue output. Battery powered.

Topcon IM-2D Lux Meter NATA CertificationTOP,IM-2D-NATA (5606) AUDigital illuminance meter with NATA certification. Measuring range from 0.1 to 19,999lx. Accuracy 5%, ±1 digit. Autoranging with silicon sensor. Battery operated.

Yokogawa 51001 Lux Meter NATA CalibratedYEW,51001-NATA (5607) AUDigital illuminance meter with NATA certification. Measuring range from 0 to 99.9/999/9,990/99,900/999,000lx . Accuracy <3,000lx 4% ±1 digit >3,000lx 6% ±1 digit. Autoranging with silicon sensor. Battery operated.

Weather StationsVaisala WXT520 Weather Station VAI,WXT520-KIT (5885) AU

Completely solid state measurement of rainfall to 0.1mm, rain intensity0.1mm/hr, rainfall duration, hail duration and intensity, barometric pressure 600 to 1100hPa, relative humidity 0 to 100%, wind speed o to 60m/s, wind direction and

temperature -52 to 60°C. The instrument is logged using a Datataker DT80M and at the a press of a button the data can be downloaded to a memory stick. Daily summary reports are email once per day. The system includes a stand and will run continuously, it includes a solar panel to keep the battery charged.

Environmental, OHS, Chemical & Laboratory www.techrentals.com.au

Page 71: normas quipment-solutions-guide

69

Environmental Flow Meters See also Flow Meters for Liquids & Gases on page 49-50

Global FP101 Digital Water Velocity MeterGLO,FP111 (6147) AUPortable flow probe - current meter for water velocity measurements in streams, channels and partially filled pipes. Propeller sensor in 50mmØ housing, fitted to telescopic handle [1.8m] with gauging marks to 900mm depth. Digital LCD flow meter display for instantaneous liquid velocity and average, maximum, stopwatch or clock. Minimum depth about 50mm. Range 0.1 to 4.5m/s ±0.05.

Hydrological Services Universal Current Meter OSS-B1 HYS,OSSB1 (6145) AU

Water current meter for measurement of flow velocity in rivers, streams, channels and open water. Robust streamlined stainless body fitted with high precision 100mmØ fan [flow range

0.025 to 5m/s]. Set of stainless wading rods for depths to 3m. Rechargeable “Hydromate” ruggedised field computer with IP65 case. Storage of fan calibration formulae for direct readout of volume-flow. Touch screen entry for set up, input, storage and download. Supplied with PC download software and cable.

Unidata 6526B-21LCD Open Channel Liquid Flow Logger with LCD ModuleUNI,6526B-21LCD (6141) AUOpen channel flow logger with field LCD display module and 10m cable (2m depth rating). Measurement and logging of flow-velocity (by Doppler), depth (by pressure) and temperature. Programmable for flow-channel profile (laptop PC required for in-situ programming via RS232C). Operating temperature range 0 to 60°C. Velocity 21 to 5,000mm/s ±2%; depth 0 to 2,000mm ±2%; temperature: -17 to 60°C ±0.1°C; log-interval 5s to 1 week; memory 120,000 samples. Programmable output to control devices such as water samplers. Detects and measures reverse flows. Charger and batteries supplied. Workhead dimensions 290 x 70 x 25mm.

Balances & Scales below 8kg See also Weighing & Counting Scales over 8kg on page 55

A&D HF-300G Mercury 300g Counting ScalesAND,HF-300G (4439) AUScales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port. Includes counting software. Can be used as counting scales.

A&D Mercury MX50 Moisture BalanceAND,MX50 (4440) AUMaximum sample weight capacity 51g, weight resolution 0.001g, moisture con-tent accuracy over 1g 0.10%, over 5g 0.02%. Halogen lamp used for heating, 400watt max. Drying temperature 50 to 200ºC. Measurement programs 20 sets, measurement mode moisture content, wet or dry, dry content, ratio, weight. Heating mode standard, automatic, quick, timer, manual. Display large VFD, interface RS-232C, CD-ROM S/W supplied. Pan sample size diameter 85mm.

Chemical & Analytical - GeneralHydramotion Viscolite 700 Portable ViscometerHYL,V700S-21 (6352) AUAdvanced portable viscometer with stainless-steel probe. Operating range 0.1 to 10,000mPaps (cps) with integral temperature correction -40 to 150ºC. Probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm (viscosity/temperature). Acetal polymer probe base for handheld or clamped operation, with coiled-cable connection to meter unit with 5 digit display. Battery powered.

Laboratory Instruments, SpectroscopyX-Rite SP60 Portable Sphere Colour SpectrophotometerXRI,SP60 (6342) AUPortable spectrophotometer for surface colour measurements. Diffuse 8° [d/8] optical geometry with fixed 8mm aperture. Tungsten source for illuminant types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard observers 2 & 10°. Blue-enhanced photodiode detectors with spectral range 400 to 700nm. Measures opacity and colour by chromatic, apparent or tristimulus calculation, with simultaneous included and excluded specular component, and spectrum at 10nm intervals. Storage of up to 2,000 samples with results download to serial printer or computer. Operation from internal rechargeable battery or AC adaptor.

Environmental, OHS, Chemical & Laboratorywww.techrentals.com.au

SOCIAL MEDIA

TechRentals is giving you greater access to news, product tips and information via a range of social media channels. With over 100 videos on our YouTube channel and regular industry related updates on twitter you will always be informed. So subscribe and follow to stay up-to-date and in-touch with our friendly team and make the most of your test and measurement equipment.

http://www.linkedin.com/company/techrentalshttp://www.twitter.com/techrentalshttp://www.youtube.com/techrentals

New items are being added to the inventoryconstantly, so if you do not see what you arelooking for please call 1800 632 652.

Page 72: normas quipment-solutions-guide

70

Security Equipment Detec DH50 Hand-held Metal Detector Kit of 4DET,DH-50-KIT4 (9208) AUKit of 4 x hand held security metal detector. Simple to operate - no adjustment needed. Audible alarm.

Detec Garrett CS5000 Walk Through Metal DetectorGAR,CS5000 (9211) AUDetects all metals. Requires assembly on-site & set-up. Adjustable sensitivity.

Prospecting Metal Detectors See also Underground Services Location on page 61

Excaliber 1000 Underwater Metal DetectorEXA,1000 (9204) AUUnderwater metal detector with 10 inch search coil. Can be used effectively in or out of the water and is capable of going down to 60 meters depth. Features two operating modes; all metal and discriminate. In discriminate mode it will ignore most ferrous objects and still detect the valuable non-ferrous objects such as gold and silver. Rechargeable battery pack separated from the electronics cylinder allows easy access for recharging.

www.techrentals.com.auOther Products

NOTES

Page 73: normas quipment-solutions-guide

71

TECHRENTALS - Your Rental Business Partner

TR0282

Cable Tester for Cat 6 and 7

techrentalsyour rental business partner

RENT FOR A DAY, A MONTH, A YEAR OR MORE

Fibre optic cable slicer and cleaver OTDR: Optical Time Domain Refl ectometer

Supplier of rental test and measurement equipment.

TechRentals can tailor a package for you to get the right gear to suit your needs.

Please call one of our Technical Sales people today on 1800 632 652

PON Meter Datacom TesterLight Source and Power meter

Micro-Ohm Meter Pressure CalibratorPower Quality Analyser

Page 74: normas quipment-solutions-guide

72

OUR BUSINESS UNITS www.techrentals.com.au

TechRentals hires specialised test equipment product solutions for a wide range of industries for periods from a day to a year or more. Products offered include power measurement and analysis, general electronic, environmental and OH&S, plus telecommunications. The leader in the industrial rental arena for more than 30 years, TechRentals also offers flexible purchasing options on selected product ranges.

www.techrentals.com.au www.techrentals.com.my1800 632 6521800 88 7368

TR Vidcom is raising standards in the dynamic computer and audio-visual industry, offering solutions for both short & long term equipment procurement and event management. TR Vidcom has superior product and industry knowledge, with a nation-wide service over nine locations across Australia. We can provide all your computer and audio-visual requirements, with national support and timely delivery of your equipment. Our customers include major corporate companies around Australia and event managers around the nation. We can deliver, install and fully train your staff on your premises.

www.trvidcom.com.auwww.videowallsaustralia.com.auwww.rent-notebook.com.au 1800 843 266

Be able to talk wherever you are by utilising the most reliable satellite communication network available. With coverage around Australia, New Zealand and surrounding island regions, you are able to stay connected with world class satellite voice, data and tracking solutions. TR Telecom can provide a tailored solution, supported by superior levels of customer service. Visit our new website, where you can rent and purchase a range of Satellite Communication equipment including Satellite Phones, BGAN Terminals, Data Accessories, Chargers, Batteries and Antennas.

www.trtelecom.com

1300 550 014

Utilising state-of-the-art technology, our experienced team delivers calibration and repair services to customers in defence, manufacturing, aviation and other high tech sectors. TR VMS calibration group has NATA accredited facilities, plus mobile calibration labs operating as needed to meet customers’ on-site demands.

www.trvms.com.au 1300 790 480

TR Hirecom is the largest two-way radio communications rental company in Australia and a division of TR Pty Ltd. Whatever your business needs, TR Hirecom have the resources to develop a customised solution that is competitively priced and of the highest standard, using state-of-the-art two-way radio communications technology from the world’s leading manufacturers.

www.trhirecom.com.au1800 222 327

Test & Measurement

Audiovisual & Business Equipment

Satellite CommunicationsYOU CAN HAVE THE BACKING OF OUR STRONG TECHNICAL CAPABILITIES AND ENJOY SUPPORT FROM SEVERAL SYNERGISTIC BUSINESS UNITS.

Calibration

Radio Communications

Page 75: normas quipment-solutions-guide

73

TECHRENTALS BUSINESS PARTNERSwww.techrentals.com.au

Acoustic Research Laboratories

Agilent

Anritsu

EXFO

Fluke

Fluke Networks

Gridsense

JDSU

Megger

SebaKMT

Testo

TECHRENTALS ARE DISTRIBUTORS AND RESELLERS FOR:

TECHRENTALS - THE PERFECT SOLUTION!

Anritsu

JDSU

Megger

Gridsense

Acoustic Research Laboratories

SebaKMT

Kingfi sher

Flir

TechRentals has a vast fl eet of products offering solutions for many markets including Aviation, HVAC, Defence, Electrical, Biomedical, Mechanical and Telco markets, however if you cannot fi nd what you are looking we have access to our international partners giving you an even larger and diverse inventory to satisfy your needs.

Remember that it is much more cost effective to Rent than to purchase outright as you are able to preserve capital for other parts of your business. However if you do need to eventually own the assets then Tech Rentals will offer a Rent with Purchase Option. Either way we will fi nd you the assets you need when you want them.

Page 76: normas quipment-solutions-guide

TR09

95

Australia 1800 632 652 www.techrentals.com.au

Malaysia603 5632 1135 www.techrentals.com.my

TechRentals New Zealand* 0800 832 473 www.techrentals.co.nz*distributor of TechRentals Australia