VISIO2 after 2007

Home

Symptoms of the problem (click on the relevant line)

No control screen display.

The control screen does not switch on or has frozen up.

The oxygen consumption is too high.

The control screen works but nothing happens, even if you override manually.

The right hand pressure gauge is below 2.5 bars on all dosers.

The right hand pressure gauge is above 2.5 bars on one of the dosers.

The pressure on the right hand pressure gauge does not reach 2.5 bars on one of the dosers.

The pressure on the left hand pressure gauge stays at 0 on one of the dosers.

The pressure on the left hand pressure gauge is above 2 bars on one of the dosers.

The Norton tube (noodle) on the outlet of one of the dosers disconnects constantly.

The equipment will not run in automatic mode.

The equipment does not work and the machine shows an error code.

The right hand pressure gauge is below 2.5 bars on one of the dosers.

Page 3: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the equipment connected to a power supply?

Page 4: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Disconnect and reconnect the device to reinitialise it.

Has the machine restarted?

Page 5: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the equipment connected to the regulator properly?

And is the pressure at 6 bars?

(sometimes the connection is poor due to oxygenation)

Page 6: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the pressure on the right hand pressure gauge at 2.5 bars?

Page 7: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the equipment connected to the regulator properly?

(sometimes the connection is poor due to oxygenation)

Page 8: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the equipment connected to the regulator properly?

And is the pressure at 6 bars?

(sometimes the connection is poor due to oxygenation)

Page 9: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Manually override in small increments by turning the regulator clockwise to 2.5 bars.

Did this help to solve your problem?

Yes No

Home

Page 10: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the pressure on the left hand pressure gauge over 2.5 bars?

Page 11: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Completely unscrew the regulator, carry out a manual override in order to remove any impurities, then reset the pressure to 2.5 bars.

If the problem persists, the doser module is defective. Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 12: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Carry out a manual override. Are the solenoid valves working?

Page 13: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Are the Norton tubes (noodles) on the doser outlet and the tank inlet disconnected?

Page 14: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

If yes If no

Home

Check the ceramic element; it may be broken or the pipe connecting to the diffuser may be disconnected.

Page 15: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the device's outlet coupling properly connected?

(risk of a poor connection due to oxygenation).

Page 16: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the diffuser clogged?

Page 17: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Check that the pipe between the device and the diffuser is not squashed or blocked, disconnect the Norton tube from the diffuser, carry out a manual override and the gas

should flow.

Does the left hand pressure gauge fall again immediately?

Page 18: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Is the diffuser clogged?

Page 19: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Check that the pipe between the device and the diffuser is not squashed or blocked, disconnect the Norton tube from the diffuser, carry out a manual override and the gas

should flow.

Does the left hand pressure gauge fall again immediately?

Page 20: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes No

Home

Have the tank and dose volumes been programmed?

Page 21: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Yes

Home

Is the programmed dose compatible with the volume programmed?

(max 120mL/L/month).

No

Page 22: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

If yes If no

Home

Check that there are no leaks in the circuit (see attached procedure).

Page 23: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Defective machine or supply

Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 24: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The equipment is ready for use.

Did this help to solve your problem?

Yes No

Home

Page 25: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The O2 supply circuit is blocked.

Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 26: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The O2 supply circuit is blocked.

Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 27: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The equipment’s outlet connection is not connected or is not connected securely (risk of poor connection due to oxygenation).

Replace the coupling.

Doser outlet 2/4 (ref: 1.6SortieDoseur2/4).

Did this help to solve your problem?

Yes No

Home

Page 28: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Clean the ceramic element (see attached procedure); check that it is working properly in a bucket before putting it back in the tank.

Did this help to solve your problem?

Yes No

Home

Page 29: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

You can repair it with a stainless steel olive or replace the entire tube.

ref: 215TA10MO

Did this help to solve your problem?

Yes No

Home

Page 30: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Replace the coupling.

Doser outlet 2/4 (ref: 1.6SortieDoseur2/4).

Did this help to solve your problem?

Yes No

Home

Page 31: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Clean the ceramic element (see attached procedure). Check that it is working properly in a bucket before putting it back in the tank.

Did this help to solve your problem?

Yes No

Home

Page 32: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Pipe blocked - replace it.

Note: This happens if you switch off the device without taking the diffuser out of the wine or if you leave it to soak in cleaning solution without disconnecting it.

If effect, the wine or cleaning solution will consume the oxygen in the tubes and rise up to the dosing device, crystallise, block all the tubes and may even damage the dosing module, resulting in

it needing to be replaced.

It is very important to remove the diffuser from the tank and to disconnect it as soon as it is no longer in use.

Did this help to solve your problem?

Yes No

Home

Page 33: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Clean the ceramic element (see attached procedure). Check that it is working properly in a bucket before putting it back in the tank.

Did this help to solve your problem?

Yes No

Home

Page 34: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Pipe blocked - replace it.

Note: This happens if you switch off the device without taking the diffuser out of the wine or if you leave it to soak in cleaning solution without disconnecting it.

If effect, the wine or cleaning solution will consume the oxygen in the tubes and rise up to the dosing device, crystallise, block all the tubes and may even damage the dosing module, resulting in

it needing to be replaced.

It is very important to remove the diffuser from the tank and to disconnect it as soon as it is no longer in use.

Did this help to solve your problem?

Yes No

Home

Page 35: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The machine has lost its calibration value; you can check it on the "SETTINGS" screen. If this value is 0, you will need to reprogramme it.

The machine is programmed in the "SETTINGS" menu: enter the code "8574" then enter the calibration value for each doser and reset the code to

0.

Did this help to solve your problem?

Yes No

Home

0.0 0.0

USER CODE

SYSTEMCODE

Page 36: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Repair following the attached instructions or contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 37: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Check the power supply and connections.

Did this help to solve your problem?

Yes No

Home

Page 38: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Either the screen or the machine is defective.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Page 39: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Set the O2 bottle outlet pressure to 6 bars.

Reminder: it is the difference in pressure between the supply at 6 bars and the back pressure at 2.5 bars that acts as a reference for the device to

operate.

Did this help to solve your problem?

Yes No

Home

Page 40: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

While carrying out a manual override, gently tap on the black screw next to the right hand pressure gauge; a solenoid valve may be stuck.

Otherwise, the solenoid valve or the solenoid valve coil is defective.

Contact our after-sales service.

Did this help to solve your problem?

Yes NoHome

Page 41: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The equipment’s outlet connection is not connected or is not connected securely (risk of poor connection due to oxygenation).

Possibly replace the regulator outlet coupling.

Ref: 3.1.SD1

Did this help to solve your problem?

Yes No

Home

Page 42: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Set the O2 bottle outlet pressure to 6 bars.

Reminder: it is the difference in pressure between the supply at 6 bars and the back pressure at 2.5 bars that acts as a reference for the device to

operate.

Did this help to solve your problem?

Yes No

Home

Page 43: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Defective dosing module.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Page 44: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Check the regulator setting by turning it anti-clockwise; if the pressure does not drop, the dosing module is defective. Contact our after-sales service for

a replacement.

Did this help to solve your problem?

Yes No

Home

Page 45: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Defective dosing module.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Page 46: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Defective solenoid valve coil.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Page 47: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Leak in the pipe between the device and the tank. Repair it with a joint or replace it.

Ref: 1.6Manchon

Did this help to solve your problem?

Yes No

Home

Page 48: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Internal circuit blocked.

Contact our after-sales service.

Note: This happens if you switch off the device without taking the diffuser out of the wine or if you leave it to soak in cleaning solution without disconnecting it.

If effect, the wine or cleaning solution will consume the oxygen in the tubes and rise up to the dosing device, crystallise, block all the tubes and may even damage the dosing module, resulting in

it needing to be replaced.

It is very important to remove the diffuser from the tank and to disconnect it as soon as it is no longer in use.

Did this help to solve your problem?

Yes No

Home

Page 49: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Defective dosing module.

Contact our after-sales service for a replacement.

Did this help to solve your problem?

Yes No

Home

Page 50: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Enter a tank volume in hL and a dose in mL/L/month.

Did this help to solve your problem?

Yes No

Home

Page 51: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Often it is an inputting error: enter the desired values again.

Did this help to solve your problem?

Yes No

Home

Page 52: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

The machine has lost its programme.

Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 53: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Contact our after-sales service.

Did this help to solve your problem?

Yes No

Home

Page 54: Next Home Visio2 troubleshooting guide Start the slide show then click Next.

Thank you for using Vivelys' online help.We hope that we have met your expectations, and are available to help if you need

any further information.

Please do not hesitate to contact us by email or telephone:

[email protected]

Home