NeNew w SSampling/ampling/SSensor ensor IInitiative (nitiative (NeSSINeSSI™)™)
Analytical Applications Analytical Applications and Web Toolsand Web Tools
Dave Veltkamp, CPACDave Veltkamp, CPAC
Overview of TalkOverview of TalkDiscuss how NeSSI™ can facilitate Discuss how NeSSI™ can facilitate laboratory applications and how laboratory applications and how current development fits lab needscurrent development fits lab needs
Examples of NeSSI™ as a platform for Examples of NeSSI™ as a platform for micro analytical devices and analyzersmicro analytical devices and analyzers
Mention some web-based resources at Mention some web-based resources at CPACCPAC
What does NeSSI™ ProvideWhat does NeSSI™ ProvideSimple “Lego-like” assemblySimple “Lego-like” assembly
Easy to re-configureEasy to re-configureNo special tools or skills requiredNo special tools or skills required
Standardized flow componentsStandardized flow components““Mix-and-match” compatibility between vendorsMix-and-match” compatibility between vendorsGrowing list of componentsGrowing list of components
Standardized electrical and communication Standardized electrical and communication (Gen II)(Gen II)
““Plug-and-play” integration of multiple devicesPlug-and-play” integration of multiple devicesSimplified interface for programmatic I/O and controlSimplified interface for programmatic I/O and control
Advanced analytics (Gen III)Advanced analytics (Gen III)Micro-analyzersMicro-analyzersIntegrated analysis or “smart” systemsIntegrated analysis or “smart” systems
NeSSI™: Enabler for NeSSI™: Enabler for MicroAnalytical MicroAnalytical
(the “rail” concept)(the “rail” concept)
Standard Mechanical Interface “Rail”
Standard Electrical (Digital) Interface “Rail”
Anyone’s Sensor Anyone’s Actuator
SAM*
Standard “hockey-puck
PC”P
V
*Sensor/Actuator Manager
Standard“connectivity
”
Where Does NeSSI™ Fit in the Where Does NeSSI™ Fit in the LabLab
Instrument/Sensor InterfacesInstrument/Sensor InterfacesDesign standards make development simplerDesign standards make development simpler
Reduced toolset to be masteredReduced toolset to be mastered Reduced sample variability to account forReduced sample variability to account for
Calibration/validation built-inCalibration/validation built-in Consistent physical environment for measurementConsistent physical environment for measurement Stream switching and/or mixing allow generation of Stream switching and/or mixing allow generation of
standards to match analytical requirementsstandards to match analytical requirements
Reaction monitoringReaction monitoringMicroreactors and continuous flow reactorsMicroreactors and continuous flow reactorsBatch reactors (with fast loop)Batch reactors (with fast loop)
Sample PreparationSample PreparationGas handling (mixing, generation, delivery)Gas handling (mixing, generation, delivery)Liquid handling (mixing, dilution, conditioning, etc.)Liquid handling (mixing, dilution, conditioning, etc.)
Special Lab NeSSI™ Special Lab NeSSI™ RequirementsRequirements
Flowing streamsFlowing streamsNeed to move liquid and gas streams through Need to move liquid and gas streams through NeSSI™ NeSSI™ Most laboratory analysis involves discrete samples Most laboratory analysis involves discrete samples rather than sample streamsrather than sample streamsAnalytical characterization of flow in NeSSI™ Analytical characterization of flow in NeSSI™ neededneeded
Heating and CoolingHeating and CoolingLaboratory applications need bothLaboratory applications need bothMay require more rapid thermal responseMay require more rapid thermal response
Integration with other lab apparatusIntegration with other lab apparatusSerial communication and legacy I/OSerial communication and legacy I/OIntegration with lab software systemsIntegration with lab software systems
Low costLow costCompeting with other solutions that don’t carry Competing with other solutions that don’t carry some of NeSSI’s more exotic featuressome of NeSSI’s more exotic features
NeSSI™ and NeSSI™ and MicroreactorsMicroreactors
Investigate integration of NeSSI™ with Investigate integration of NeSSI™ with continuous flow microreactorscontinuous flow microreactors
Initially as analyzer interfaceInitially as analyzer interface
Eventually as complete fluidics frameworkEventually as complete fluidics framework
Automation requires Gen IIAutomation requires Gen II
Initial Sensor IntegrationInitial Sensor Integration
Online RamanProbe
Sample FlowCell
ContinuousMicroreactor
Initial Sensor IntegrationInitial Sensor Integration
NeSSI Raman Sampling NeSSI Raman Sampling BlockBlock
• Parker Interflow NeSSI substrate• Sample conditioning to induce
backpressure to reduce bubble formation and the heated substrate allows analysis at reactor conditions
NESSI Microreactor NESSI Microreactor Sampling/Calibration Sampling/Calibration
SystemSystemReactor Feed 1
Reactor Feed 2
Product Stream
Real-timeCalibration
prod
RamanProbe
Pump 1
Pump 2
waste
Benefits of NeSSI™ to Benefits of NeSSI™ to Reaction AnalysisReaction Analysis
Conditioning and manipulation Conditioning and manipulation of sample introduced to analyzerof sample introduced to analyzerBetter control of sample physical Better control of sample physical parametersparameters
PhasePhaseTemperatureTemperatureVelocityVelocity
Ability to implement sensors at points Ability to implement sensors at points where measurement parameters are where measurement parameters are optimaloptimalFlexibility for performing calibration online Flexibility for performing calibration online without removing sensorwithout removing sensorFast switching of streams for Fast switching of streams for measurement, calibration or validationmeasurement, calibration or validation
NeSSI™ Fermentation NeSSI™ Fermentation SystemSystem
Switching filter system to handle Switching filter system to handle particulate laden liquid streamsparticulate laden liquid streams
Cells in fermentation brothCells in fermentation broth
Supplied by Bob Sherman, CircorSupplied by Bob Sherman, Circor
Interested in plugging, cleaning, and Interested in plugging, cleaning, and other issues related to bio/pharma other issues related to bio/pharma applicationsapplications
2 Filters
Fermentation Headspace Fermentation Headspace SystemSystem
Designed to allow fermentation Designed to allow fermentation headspace monitoringheadspace monitoring
Fast circulation loop of headspace gasesFast circulation loop of headspace gases
Addition of calibration gasesAddition of calibration gases
Output to process Mass spectrometerOutput to process Mass spectrometer
Fermentor Headspace Loop
Calibration gases
ToMassSpec
MFC
MFC
MFC
MFC
MFC
Example Sensor InterfaceExample Sensor InterfaceSensor is a vapochromatic compoundSensor is a vapochromatic compound
Responds to different compounds by Responds to different compounds by intensity and wavelength shifts in intensity and wavelength shifts in fluorescence signalfluorescence signalOptical detection using simple VIS Optical detection using simple VIS spectrometerspectrometer
LED excitation light sourceLED excitation light source Simple reflection optical fiber light pathSimple reflection optical fiber light path
Use of BallProbe to provide single-sided Use of BallProbe to provide single-sided optical interfaceoptical interface
Vapochrome coated on ball surfaceVapochrome coated on ball surface
NeSSI™ system to control delivery and NeSSI™ system to control delivery and mixing of gas streammixing of gas stream
NeSSI Gas Mixing SystemNeSSI Gas Mixing System Using a customized ballprobe reflectance probe for vapochromic detection
- Ocean optics spectrometer- ballprobe coated with vapochrome
- NeSSI substrate with 2 MFC’s
NeSSI Gas Mixing SystemNeSSI Gas Mixing System
Fluorescence response of vapochrome to dry N2 and cylinder air
200
400
600
800
600 650 700 750 800 850
200
400
600
800
600 650 700 750 800 850
Wavelength (nm)
Inte
nsi
ty (
counts
)
Dry N2
Air
Experiment- 25 ms- 20 accums
Air
Experiment- 25 ms- 20 accums
Vapochrome SummaryVapochrome Summary
Use of NeSSI™ system allowed for Use of NeSSI™ system allowed for better control and characterization of better control and characterization of sensor responsesensor response
Less variability and faster response to gas Less variability and faster response to gas composition changescomposition changesAbility to generate gas mixtures Ability to generate gas mixtures in situin situ
Opens up potential for additional Opens up potential for additional studies to quantitatively characterize a studies to quantitatively characterize a library of vapochromatic compounds to library of vapochromatic compounds to different analytesdifferent analytesInvestigate optimal sensor designInvestigate optimal sensor design
NeSSINeSSI™™ Knowledge Network Knowledge Network
Main topic page divided into Main topic page divided into 4 sections4 sections
News and InformationNews and Information
Discussion (NeSSI Q&A)Discussion (NeSSI Q&A)
Component ListComponent List Only Manufacturers group may Only Manufacturers group may
post herepost here
Testing and ExamplesTesting and Examples
Main NeSSI™ web siteMain NeSSI™ web sitehttp://http://www.cpac.washington.edu/NeSSI.htmwww.cpac.washington.edu/NeSSI.htm
NKN can be found atNKN can be found athttp://http://www.cpac.washington.edu/NeSSI/NKN.htmlwww.cpac.washington.edu/NeSSI/NKN.html
Component List Sub-topicsComponent List Sub-topicsPage shown from the “Valve, Manual” Page shown from the “Valve, Manual” topictopic
Listing of topics under manual valve main Listing of topics under manual valve main topictopic
Number of posts will correspond to Number of posts will correspond to different available componentsdifferent available components
Component List PageComponent List PageExample post Example post from the from the component component list pagelist page
URL from URL from VendorVendorSpec. sheet Spec. sheet or linkor linkPicture, Picture, description, or description, or link to more link to more informationinformation
Other Vendors are currently working to Other Vendors are currently working to populate the list with more componentspopulate the list with more components
User Self-RegistrationUser Self-RegistrationAllows users to setup accountsAllows users to setup accounts
Selecting to join Selecting to join “Manufacturers” group will “Manufacturers” group will queue user’s registration until a queue user’s registration until a moderator approves it.moderator approves it.Membership in other groups Membership in other groups automatically approved automatically approved immediately immediately
Profile data will be used for Profile data will be used for NeSSI™ mailing listNeSSI™ mailing list
Check the options available from Check the options available from the “Edit Profile” link once user the “Edit Profile” link once user activates accountactivates account
Once user submits registration Once user submits registration form, they are sent an email form, they are sent an email with instructions for activating with instructions for activating their new accounttheir new account
Your account is not active till Your account is not active till you log in and follow the you log in and follow the instructions in the emailinstructions in the email
NKN ConclusionNKN ConclusionNew software and web site ready to be New software and web site ready to be usedused
Need to work on additional instruction sheetsNeed to work on additional instruction sheetsThanks to Michelle Cohn, UOP for helping CPAC Thanks to Michelle Cohn, UOP for helping CPAC buy a new server to host NeSSI™ and NKN web buy a new server to host NeSSI™ and NKN web sitessites
NeSSI Component List is becoming NeSSI Component List is becoming populatedpopulated
Major manufacturers already signed up and Major manufacturers already signed up and starting to supply contentstarting to supply contentNeed to get smaller suppliers to do the sameNeed to get smaller suppliers to do the same
Need to get user community to register Need to get user community to register and start using itand start using it
Expect Email announcements soon (1-2 weeks)Expect Email announcements soon (1-2 weeks)
NeSSI™ Sensor SurveyNeSSI™ Sensor Survey
The purpose of this survey is to gather The purpose of this survey is to gather information on the sensors and information on the sensors and actuators needed for NeSSI Generation actuators needed for NeSSI Generation II Sample Systems, Analytical Systems, II Sample Systems, Analytical Systems, and Cluster Applications. and Cluster Applications.
This data will be shared with sensor and This data will be shared with sensor and instrument vendors to help them prioritize instrument vendors to help them prioritize development of the devices needed across development of the devices needed across industries and applications. industries and applications. The more information you can provide, the The more information you can provide, the faster better products and performance faster better products and performance can be delivered can be delivered
NeSSI™ Sensor Survey NeSSI™ Sensor Survey (cont.)(cont.)
On-line survey form on the CPAC On-line survey form on the CPAC NeSSI™ web siteNeSSI™ web site
http://www.cpac.washington.edu/NeSSI/Chttp://www.cpac.washington.edu/NeSSI/CPAC_NeSSI_Sensor_Survey.htmPAC_NeSSI_Sensor_Survey.htm
Questions about condition sensorsQuestions about condition sensorsAre you interestedAre you interestedHow would you rank their importanceHow would you rank their importanceOperating rangesOperating ranges
Questions about analytical sensorsQuestions about analytical sensorsAre you interestedAre you interestedHow would you rank their importanceHow would you rank their importanceOperating rangesOperating ranges
Questions about actuatorsQuestions about actuatorsQuestions about “Clusters”Questions about “Clusters”Optional contact informationOptional contact information
NeSSI™ Sensor Survey NeSSI™ Sensor Survey ResultsResults
Condition SensorsCondition Sensors
Analytical SensorsAnalytical Sensors
Count Mean Rank Median RankPressure 14 3.9 4Temp 14 3.9 4Flow 15 4.0 5Humidity 13 3.2 3Cond. 9 2.6 3Other 6 3.0 3Combined 13 3.5 3
O2 NOx pH H2 CO CO2 Raman NIRCount 13 7 10 13 10 8 7 12
Mean Rank 3.8 3.4 3.0 3.5 3.3 3.1 3.0 3.2Med Rank 4 4 3 3 3 3 3 3
MIR UV/Vis NMR MS GC LC ViscosityCount 11 10 3 7 12 2 7
Mean Rank 3.3 2.9 2.0 3.1 4.0 2.5 3.0Med Rank 3 3 1 3 4 2.5 3
NeSSI™ Sensor Survey NeSSI™ Sensor Survey ResultsResults
ActuatorsActuators
ClustersClusters
11 of the 15 respondents indicated they 11 of the 15 respondents indicated they would share information with Vendorswould share information with Vendors
Count Mean Rank Median RankOn/Off Valve 15 3.7 4 Ball 11 Diaphragm 11Modulator Valve 11 3.7 4Solenoid Valve 12 3.3 3MFC 13 3.8 4VFC 11 3.6 3
CountCEMS 9Clean Water 8Waste Water 6HRVOC 5
NeSSI™ Sensor Survey NeSSI™ Sensor Survey (cont.)(cont.)
Plan is to continue to solicit responses from Plan is to continue to solicit responses from usersusers
Additions to survey questions or content welcomeAdditions to survey questions or content welcome
May expand survey activities to help provide May expand survey activities to help provide market directions to suppliersmarket directions to suppliers
Other aspects of NeSSI™ developmentOther aspects of NeSSI™ development Applet Software and other issues relate to SAMApplet Software and other issues relate to SAM New opportunities or innovationsNew opportunities or innovations
Need to reach beyond the normal NeSSI™ Need to reach beyond the normal NeSSI™ enthusiastsenthusiasts
Combined with the discussion board, surveys Combined with the discussion board, surveys provide a valuable resource for both end-provide a valuable resource for both end-users and manufacturers of NeSSIusers and manufacturers of NeSSI
Summary & ConclusionSummary & ConclusionNeSSI™ Gen II ready for developmentNeSSI™ Gen II ready for development
Working spec/prototype design completeWorking spec/prototype design complete
Prototypes demonstrated in real Prototypes demonstrated in real applicationsapplications
Near resolution of the NeSSI™ bus issueNear resolution of the NeSSI™ bus issue
For some laboratory applicationsFor some laboratory applicationsGen II and Gen III will immediately work Gen II and Gen III will immediately work and provide benefitsand provide benefits
The future holds a lot of promise!!The future holds a lot of promise!!