New Products Modified Products Discontinued Products€¦ · 72 84 71 84 83 72 71 54 53 A1 A2 2/T1...

24
TIME006 Vol. 6 Modified Products Miniature control relays / HH52, HH54 series ............................................................................................. 22 Miniature control relays / Sockets for rail mounting ..................................................................................... 22 Display lights and multi display lights .......................................................................................................... 23 Manual motor starters / BM3 series ............................................................................................................ 23 Discontinued Products AS-Interface Waterproof connector-type slave module FM6D, FM6B ....................................................... 24 AS-Interface Power supply FP1B-JNW213 .............................................................................................. 24 AS-Interface DeviceNet/AS-i gateway FC2L-DL ...................................................................................... 24 New Products Reversing standard type contactors SC-E series ........................................................................................ 2 Manual motor starters Power supply terminal covers .................................................................................. 5 22mm-dia. emergency stop pushbutton switches AR22 series .................................................................... 6 22mm-dia. emergency stop pushbutton switches AM22 series ................................................................... 8 Display lights DP36 and 40 series ............................................................................................................. 10 Power terminal blocks SKT series .............................................................................................................. 12 AC voltage and current transducers WT2AC series ................................................................................... 14 Arresters for low voltage circuit CN233 series ........................................................................................... 16 AC power distribution monitoring unit for one feeder, F-MPC04 series and CC2D CTs ............................. 18

Transcript of New Products Modified Products Discontinued Products€¦ · 72 84 71 84 83 72 71 54 53 A1 A2 2/T1...

TIME006

Vol. 6

Modified ProductsMiniature control relays / HH52, HH54 series ............................................................................................. 22Miniature control relays / Sockets for rail mounting ..................................................................................... 22Display lights and multi display lights .......................................................................................................... 23Manual motor starters / BM3 series ............................................................................................................ 23

Discontinued ProductsAS-Interface Waterproof connector-type slave module FM6D, FM6B....................................................... 24AS-Interface Power supply FP1B-JNW213 .............................................................................................. 24AS-Interface DeviceNet/AS-i gateway FC2L-DL ...................................................................................... 24

New ProductsReversing standard type contactors SC-E series ........................................................................................ 2Manual motor starters Power supply terminal covers .................................................................................. 522mm-dia. emergency stop pushbutton switches AR22 series .................................................................... 622mm-dia. emergency stop pushbutton switches AM22 series ................................................................... 8Display lights DP36 and 40 series ............................................................................................................. 10Power terminal blocks SKT series .............................................................................................................. 12AC voltage and current transducers WT2AC series ................................................................................... 14Arresters for low voltage circuit CN233 series ........................................................................................... 16AC power distribution monitoring unit for one feeder, F-MPC04 series and CC2D CTs ............................. 18

FUJI ED & C TIMES Vol. 62

New ProductsNew Products

Features• Designed for the forward-reverse operation and plugging

stop of 3-phase induction motors.• Mechanical interlock mechanism provided• Snap-on 35mm top hat rail mounting

SC-E3RM

KK03-040

New ProductsNew Products

Reversing standard type contactorsSC-E series

Ideal for reversing 3-phase induction motors

Types and ratings

Reversing contactor Power connection kits

KK03-047

SZ-ERW1/A + SZERW1/B

• AC operated

• DC operated

DC reversing magnetic contactors are also available.

Contact FUJI .

Framesize

E02

E03

E04

E05

E1

E2

E2S

E3

E4

E5E6E7

Motor rating (kW)3-phase (AC-3)200-240V 2.2 3 4 5.5 7.5 11 15 18.5

22

303745

200-240V 9

12

18

25

32

40

50

68

80

105125150

380-440V 9

12

18

25

32

40

50

65

80

105125150

200-240V 20

20

25

32

50

60

65

100

150

150150200

380-440V 20

20

25

32

50

60

65

100

150

150150200

Rated thermal current (A)

20

20

25

32

50

60

65

100

150

150150200

Auxiliary contact arrangement

(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(2NO+2NC) x 2(2NO+2NC) x 2(2NO+2NC) x 2

Type

SC-E02RM *

SC-E03RM *

SC-E04RM *

SC-E05RM *

SC-E1RM *

SC-E2RM *

SC-E2SRM *

SC-E3RM *

SC-E4RM *

SC-E5RM SC-E6RM SC-E7RM

Rated operational current (A)3-phase (AC-3) Resistive load (AC-1)

380-440V 4 5.5 7.5 11 15 18.5 22 30

40

556075

Notes: • Ratings conform to IEC standard• The above types are shipped in a set containing two magnetic contactors,

one SZ-RM mechanical interlock unit, two front mounting auxiliary contact blocks, and electrical interlock wiring. The power connection kit

for the reversing contactor is sold separately.

• To prevent short-circuit faults when using SC-E02RM to SC-E04RM types for high-speed switching, provide a time delay relay or other electrical interlock to ensure that the switching time is 15ms min.* Equipped with the SZ-A11/T, SZ-A02/T, SZ-A31/T, or SZ-A22/T front mounting auxiliary contact block.

Further Information

3FUJI ED & C TIMES Vol. 6

New Products

Dimensions, mm

Reversing standard type contactors SC-E series New Products

• Power connection kits for reversing

SC-E02RM, 03RM, 04RM, 05RM

SC-E1RM, E2RM, E2SRM

SC-E3RM, E4RM

wiring diagrams• AC operated

Power connection kitTypeSZ-ERW1/A (Line side)SZ-ERW1/B (Load side)SZ-ERW1/D (Load side)SZ-ERW2/A (Line side)SZ-ERW2/B (Load side)SZ-ERW2/D (Load side)SZ-ERW3/A (Line side)SZ-ERW3/B (Load side)SZ-ERW3/D (Load side)

Used with

SC-E02 to SC-E05SC-E02/G to SC-E05/G

SC-E1 to E2SSC-E1/G to E2S/G

SC-E3, E4SC-E3/G, E4/G

Power connection kitTypeSZ-ERW4/A (Line side)SZ-ERW4/B (Load side)SZ-ERW5/A (Line side)SZ-ERW5/B (Load side)SZ-ERW6/A (Line side)SZ-ERW6/B (Load side)

Used with

SC-E5

SC-E6

SC-E7

Panel drilling

21 3535

6014

.5

Mounting hole4-M4

8.561

92109

119 (Rail height 15)

Coil terminalM3.5

5699

Main terminal

AuxiliaryterminalM3.5

28

7.710

10.513

4920

81

70.5

Mass: 0.8kg (4-aux. contacts)0.77kg (2-aux. contacts)

Mass: 1.3kg (4-aux. contacts)1.27kg (2-aux. contacts)

Panel drilling

10.5 2

107

124

134 (Rail height 15)

67

121

2245 45

75

67

Mounting hole4-M4

Main terminal

Coil terminalM3.5

AuxiliaryterminalM3.5

9.5

65.5

5718

.5

90

16.5

28

10

7.7

86

Mass: 2.24kg (4-aux. contacts)2.21kg (2-aux. contacts)

Panel drilling

10.5 2.5

72.5

121

139

149 (Rail height 15)

80

147Main terminal

Coil terminalM3.5

AuxiliaryterminalM3.5

(54 to)60 (54 to)60

9013

80

Mounting hole4-M4

28 7719

.511

2

20.57.7

10

108

23

54

53A2A1

6/T3 4/T2 2/T1

53 1/L1 3/L2 5/L3 61A1 A2

6254

1/L1 3/L2 5/L3 61

62 6/T3 4/T2 2/T1

2/T1 4/T2 6/T3 62

61 5/L3 3/L2 1/L1

52 62

A2A161 5/L3 3/L2 1/L1 51

2/T1 4/T2 6/T3

A1 A251

52

2/T1 4/T2 6/T3 62

61 5/L3 3/L2 1/L1

54 62

A2A161 5/L3 3/L2 1/L1 53

2/T1 4/T2 6/T3

A1 A253

54

73

74

83

84

73

74 84

83

83

8472

71

84

83

72

71

54

53A2A1

6/T3 4/T2 2/T1

53 1/L1 3/L2 5/L3 61A1 A2

6254

1/L1 3/L2 5/L3 61

62 6/T3 4/T2 2/T1

(1NO+1NC) x 2

(2NO+2NC) x 2

(3NO+NC) x 2

2NC x 2

FUJI ED & C TIMES Vol. 64

Dimensions, mm

SC-E5RM

SC-E6RM

• SC-E7RM

wiring diagrams• AC operated

Reversing standard type contactors SC-E series New Products

1.6

82

4

137

Mounting hole 3-M5

Auxiliary terminal M3.5

150

7.5

165

111

200

230

Coil terminalM3.5

Main terminal

32

129

10.5

155

Mass : 4.64kg

1.6 4

83

145

175

7.5

190

123

220250

Mounting hole 3-M5 Auxiliary terminal M3.5

Coil terminalM3.5

Main terminal

32

169.

5

143

16

Mass : 5.8kg

2 484

147

200

7.5

215

138260

290

Mounting hole 3-M6

Auxiliary terminal M3.5

Main terminalCoil terminalM3.5

35

146

27

175

Mass : 6.8kg

54

53A2A1

6/T3 4/T2 2/T1

53 1/L1 3/L2 5/L3 61A1 A2

6254

1/L1 3/L2 5/L3 61

62 6/T3 4/T2 2/T1

2/T1 4/T2 6/T3 62

61 5/L3 3/L2 1/L1

52 62

A2A161 5/L3 3/L2 1/L1 51

2/T1 4/T2 6/T3

A1 A251

52

2/T1 4/T2 6/T3 62

61 5/L3 3/L2 1/L1

54 62

A2A161 5/L3 3/L2 1/L1 53

2/T1 4/T2 6/T3

A1 A253

54

73

74

83

84

73

74 84

83

83

8472

71

84

83

72

71

54

53A2A1

6/T3 4/T2 2/T1

53 1/L1 3/L2 5/L3 61A1 A2

6254

1/L1 3/L2 5/L3 61

62 6/T3 4/T2 2/T1

(1NO+1NC) x 2

(2NO+2NC) x 2

(3NO+NC) x 2

2NC x 2

5FUJI ED & C TIMES Vol. 6

Dimensions, mm

Features• Combining the BZ0TCRE power supply terminal cover and

BZ0TKUAB short-circuit alarm contact block in a FUJIBM3R series manual motor starter (MMS) allows it to beused as a manual self-protected combination controller(Type E combination motor controller). In the BM3V series,the BZ0TCRE power supply terminal cover is not necessaryto fulfill the UL489 insulation distance requirement.

• Combining the BZ0TCRE power supply terminal cover andBZ0TKUAB short-circuit alarm contact block in acombination starter formed by a BM3R MMS and an SC-series magnetic contactor allows it be used as a self-protected combination controller (Type F combination motorcontroller). In the BM3V series, the BZ0TCRE power supplyterminal cover is not necessary to fulfill the UL489 insulationdistance requirement.

Type E advantages• Since the Type E can be used for branch circuit protection

(BCP) as stipulated in NEC 430.52(c)(6), there is no need toprovide upstream UL489-approved BCPs as short-circuitprotection for motor branching circuits. Ordinarily, aseparate BCP is necessary for each motor.

• It takes up less space inside the control panel. Note: Using Type E to eliminate the need for a BCP applies

only to motor load circuits. It cannot be applied to otherloads, such as resistance load and lamp load circuits.

Power supply terminal coverBZ0TCRE

Manual motor startersPower supply terminal covers

New power supply terminal covers allow UL508Type E and UL508 Type F applications for MMSs

MMS with BZ0TCRE

Type: BZ0TCRE

Type F advantages• By including a compliant MMS in the Type E and applying it

as a BCP as stipulated in NEC 430.52(c)(6), there is noneed to provide upstream UL489-approved BCPs as short-circuit protection for motor branching circuits. Ordinarily, aseparate BCP is necessary for each motor.

• It takes up less space inside the control panel. Note: Using Type F to eliminate the need for a BCP applies

only to motor load circuits. It cannot be applied to otherloads, such as resistance load and lamp load circuits

New ProductsNew Products

10.8

8

10.5

35.5

8

10.5

5.4

13

55.5

45

L1 135 L2L3

1 L1 3 L2 5 L3

3-ø7.5

FUJI ED & C TIMES Vol. 66

New ProductsNew Products

Features• Reliability of safety functions increased by integrated

operator/contact block construction.• LED (24V AC/DC) and neon (110V, 120V, 220V, 240V AC)

illuminated types available, with interconnected lamp circuitthat turns the lamp on when the contacts are closed.

• White arrow on red button clearly indicates push-lock/turn-reset direction.

• Combination of AU-flashed Ag contacts and slidingmechanism ensures high contact reliability.

• Terminal cover for protection degree IP2X increases workersafety by preventing fingers from accidentally touchingcharged parts.

• FUJI original trigger action mechanism stops contacts fromoperating until the button is locked, to prevent accidentalpressing by a person or object.

• Forced contact opening mechanism securely breaks thecircuit even during errors, such as the partial welding of 1NCcontacts.

• Conforms to international standards, including UL/CSA andEN European Standards (TÜV), and bears CE markings.

22mm-dia. emergency stoppushbutton switches AR22 series

Integrated operator/contact block improvesreliability.

• Emergency stop pushbutton switches EN418Forced contact opening and trigger action mechanisms

• Emergency stop illuminated pushbutton switches EN418Forced contact opening and trigger action mechanisms

Contact arrangement1NC1NO+1NC2NC

Button colorRed

TypeAR22VGE-01RAR22VGE-11RAR22VGE-02R

Operator40mm dia.Push-lock, turn-reset

Type of lampLED lampFull-voltage type

Neon lampFull-voltage type

Lamp voltage24V AC/DC

110V AC: H120V AC: K220V AC: M240V AC: P

Contact arrangement1NC1NO+1NC2NC1NC1NO+1NC2NC

Button colorRed

Red

TypeAR22VGF-01E3RAR22VGF-11E3RAR22VGF-02E3RAR22VGF-01 1RAR22VGF-11 1RAR22VGF-02 1R

Operator40mm dia.Push-lock, turn-reset

Note: • Replace the mark by the lamp voltage code. 110V AC: H, 120V AC: K, 220V AC: M, 240V AC: P• Lamp contacts are built-in, and switch operation and lamp circuit are interconnected. When current is applied to the lamp circuit, the lamp turns on as soon as the contacts are colsed.

AR22VGEEmergency stoppushbutton switch

AR22VGFEmergency stopilluminated pushbutton switch

KK03-037 KK03-036

Types and ratings

7FUJI ED & C TIMES Vol. 6

New Products22mm-dia. emergency stop pushbutton switch AR22 series

Dimensions, mm

Specifications

Operating characteristics

Contact ratings

Standards

Rated insulation voltage UiDurability

Operating frequencyWithstand voltageInsulation resistanceVibration

Shock

Ambienttemperature

Humidity (in box)

Operator protectiondegree

Terminal protection degree

250V AC/DCMin. 100000 operationsMin. 100000 operations1800 operations/hour (on-load factor 40%)2500V AC 1minute100MΩ (500V DC megger)Malfunction durability: 10-55Hz double amplitude 0.1mmMechanical durability: 16.7Hz double amplitude 3.0mmMalfunction durability: 150m/s2

Mechanical durability: 500m/s2

-20 to +60°C (Illuminated type: -20 to +50°C)No icing, no condensation-40 to +80°C45 to 85%RH (at -5 to +40°C)No icing, no condensationIEC 60529: IP65JEM 1030: IP65fIEC 60529: IP2X

MechanicalElectrical

Operating

Storage

Ratedoperationalvoltage Ue (V)

24120125240250

Ratedthermalcurrent Ith (A)

10

Rated operational current le (A)ACAC15 (Ind. load)63—3—

DCDC13 (Ind. load)1.5—0.3—0.15

JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R500281370001)

Contactrating code

B300

• AC (COSø=0.35)

Contactrating code

Q300

• DC (Time constant T0.95=6P)

120VMake (A)30

Break (A)3

240VMake (A)15

Break (A)1.5

250VMake/Break (A)0.27

125VMake/Break (A)0.55

UL and CSA

OperatorRequired operating forceOperating strokeResetting operation angleRequired resetting force

Push-lock, turn-reset26NApprox. 10mmApprox. 45°Approx. 0.2N•m

UL508CSA C22.2 No. 14EN60947-5-1EN60947-5-5

File No. E44592 (UL Recognized)File No. E44592 (c-UL Recognized)TÜV licence No. R500281370001

43

Terminal No. 2 (12)

Terminal No. 1 (11)

Terminal screw M3.5

Note: Terminal No. shown in ( ) are for contact arrangement 2NC.

Lamp terminal screw M3.5(Illuminated type only)

Terminal No. 3 (21)

ø30

4057 32

55

Terminal No. 4 (22)

Terminal cover

Terminal No. X2

Spring washer

Packing

Panel thickness1 to 6

NutTerminal No. X1

FUJI ED & C TIMES Vol. 68

New ProductsNew Products

Features• White arrow on red button clearly indicates push-lock/turn-

reset direction.• FUJI original trigger action mechanism stops contacts from

operating until the button is locked, to prevent accidentalpressing by a person or object.

• Forced contact opening mechanism securely breaks thecircuit even during errors, such as the partial welding of 1NCcontacts.

• Conforms to international standards, including UL/CSA andEN European Standards (TÜV), and bears CE markings.

22mm-dia. emergency stoppushbutton switches AM22 series

Emergency stop pushbutton switches with lockingnut on the front panel.

AM22V0EEmergency stoppushbutton switch

AM22V0FEmergency stopilluminated pushbutton switch

KK02-236 KK02-240, 239

Types and ratingsEmergency stop pushbutton switches EN418Forced contact opening and trigger action mechanisms

Emergency stop illuminated pushbutton switches EN418Forced contact opening and trigger action mechanisms

Contactarrangement1NC1NO+1NC2NC3NC2NO+2NC4NC1NC1NO+1NC2NC3NC2NO+2NC4NC

ButtoncolorRed

Red

Type

AM22V0E-01RAM22V0E-11RAM22V0E-02RAM22V0E-03RAM22V0E-22RAM22V0E-04RAM22VSE-01RAM22VSE-11RAM22VSE-02RAM22VSE-03RAM22VSE-22RAM22VSE-04R

Operator

40mm dia.Push-lock, turn-reset

29mm dia.Push-lock, turn-reset

Notes: • Up to 4-contact blocks are available.• NO contact is used for overlap contact.

Lampvoltage

Code

Full-voltage6VACA

24VAC/DCE

With transformer110VACH

127VACL

220VACM

254VACQ

380VACS

440VACT

480VACV

550VACW

Trans-former

Without

With

Without

With

Without

With

Lamp voltage

24V AC/DC

110V AC: H220V AC: M

24V AC/DC

110V AC: H220V AC: M

24V AC/DC

110V AC: H220V AC: M

Note: Replace the mark by the lamp voltage code. 110V AC: H, 220V AC: M

Contactarrangement

1NC1NO+1NC2NC3NC1NC1NO+1NC2NC1NC1NO+1NC2NC3NC1NC1NO+1NC2NC1NC1NO+1NC2NC3NC1NC1NO+1NC2NC

Buttoncolor

Red

LED lampType

AM22V0F-01E3RAM22V0F-11E3RAM22V0F-02E3RAM22V0F-03E3RAM22V0F-01 3RAM22V0F-11 3RAM22V0F-02 3RAM22VSF-01E3RAM22VSF-11E3RAM22VSF-02E3RAM22VSF-03E3RAM22VSF-01 3RAM22VSF-11 3RAM22VSF-02 3RAM22VDF-01E3RAM22VDF-11E3RAM22VDF-02E3RAM22VDF-03E3RAM22VDF-01 3RAM22VDF-11 3RAM22VDF-02 3R

Operator

40mm dia.Push-lock,turn-reset

29mm dia.Push-lock,turn-reset

Transparentcolored

40mm dia.Push-lock,turn-reset

• LED lamp voltage

Notes: • 6V AC LED lamp is used for the separate mounting transformer.• NO contact is used for overlap contact.• Switch operation and lamp circuit are not interconnected.

9FUJI ED & C TIMES Vol. 6

New Products22mm-dia. emergency stop pushbutton switch AM22 series

Dimensions, mm

Specifications

Operating characteristics

Contact ratings

Standards

Rated thermal currentRated insulation voltageUiDurability

Operating frequencyWithstand voltageInsulation resistanceVibration

Shock

Ambienttemperature

Humidity (in box)

Operator protectiondegree

10A600V AC/DC(Illuminated full-voltage type 250V AC/DC)Min. 300000 operationsMin. 300000 operations1200 operations/hour (on-load factor 40%)2500V AC 1minute100MΩ (500V DC megger)Malfunction durability: 10-55Hz double amplitude 0.1mmMechanical durability: 16.7Hz double amplitude 3.0mmMalfunction durability: 150m/s2

Mechanical durability: 500m/s2

-20 to +60°C (Illuminated type: -20 to +50°C)No icing, no condensation-40 to +80°C45 to 85%RH (at -5 to +40°C)No icing, no condensationIEC 60529: IP65JEM 1030: IP65f

MechanicalElectrical

Operating

Storage

Rated operational voltageUe (V)

24120125240250480600

Contactratingcode

A600

• AC (COSø=0.35)

Contactratingcode

Q600

• DC (Time constant T0.95=6P)

Rated operational current le (A)ACAC15 (Ind. load)66—6—2.52

DCDC13 (Ind. load)2—0.65—0.23——

120VMake(A)60

Break(A)6

240VMake(A)30

Break(A)3

480VMake(A)15

Break(A)1.5

600VMake(A)12

Break(A)1.2

250VMake/Break(A)0.27

125VMake/Break(A)0.55

300-600VMake/Break(A)0.1

JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R50028146)

UL and CSA

OperatorRequired operating forceOperating strokeResetting operation angleRequired resetting force

Push-lock, turn-resetApprox. 23NApprox. 9mmApprox. 60°Approx. 0.25N•m

UL508CSA C22.2 No.14EN 60947-5-1EN 60947-5-5

File No. E 44592 (UL Listed)File No. LR 20479TÜV licence No. R50028146

• 40mm dia. push-lock, turn-reset AM22V0E

• 40mm dia. push-lock, turn-reset with transformer AM22V0F

59.5

44

39.5

32.51

37

ø40

37

Terminal screw M3.5

Panelthickness1 to 6

NutPacking

30

ø16

Terminal cover

Operation angle: 60°

59.5(63.5 *1)

39.5

32.51

44 37 37

24.5

*1

Terminal screw M3.5

Panelthickness1 to 6

NutPacking ø16

30

ø40

Terminal cover

Operation angle: 60°Transformer

Note: *1 Dimensions for the types with transformers of the lamp voltages 254V to 550V AC.

FUJI ED & C TIMES Vol. 610

New ProductsNew Products

Features• Employs high-brightness LED• New LED lamp significantly reduces power consumption and

mass.• Reduces wiring work and improves safety by integrating the

FUJI self-lifting terminal (quick mounting terminal) andterminal cover

• LED lamp incorporates a circuit to prevent lighting errors.• Modular design of LED unit allows easy changes in colors

and color arrangement (two- and three-split rectangularillumination faces).

• Can be used with film legend plates.• Ideal for side-by-side mounting

Display lightsDP36 and 40 series

New design with high-brightness LED and self-liftingterminal improves safety and working conditions.

DP36 seriesKK03-072A

Types and ratings• DP36 series (LED lamp)

Shape of illumination face

Square, 36x36mm

Rectangular, 36x72mm

DP36S1N

DP36T1N

DP36T3N

Illuminationtype

Full face

Full face

2-split face

3-split face

Voltage inputtype

Full voltage

With resistor unit

With CR unit

Full voltage

With resistor unitWith CR unitFull voltage

With resistor unitWith CR unitFull voltage

With resistor unitWith CR unit

Lamp voltage

12V AC/DC24V AC/DC100 to 110V AC/DC

200 to 220V AC/DC

12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC

Type

DP36S1N- B3DP36S1N- E3DP36S1N- H3

DP36S1N- M3

DP36T1N- B3DP36T1N- E3DP36T1N- H3DP36T1N- M3DP36T2N- B3DP3612N- E3DP36T2N- H3DP36T2N- M3DP36T3N- B3DP36T3N- E3DP36T3N- H3DP36T3N- M3

Specify the illuminationcolor code in the mark.

Red: RGreen: GYellow: YOrange: AWhite: WBlue: SSnow-white: P

Notes: • Voltages other than above are available.• DP36S1N, T1N and T2N with check terminals are also available.

11FUJI ED & C TIMES Vol. 6

New ProductsDisplay lights DP36 and 40 series

Dimensions, mm

• DP40 series (LED lamp)

Shape of illumination face

Square, 40x40mm

Rectangular, 40x80mm

DP40S1N

DP40T1N

DP40T3N

Illuminationtype

Full face

Full face

2-split face

3-split face

Voltage inputtype

Full voltage

With resistor unit

With CR unit

Full voltage

With resistor unitWith CR unitFull voltage

With resistor unitWith CR unitFull voltage

With resistor unitWith CR unit

Lamp voltage

12V AC/DC24V AC/DC100 to 110V AC/DC

200 to 220V AC/DC

12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC

Type

DP40S1N- B3DP40S1N- E3DP40S1N- H3

DP40S1N- M3

DP40T1N- B3DP40T1N- E3DP40T1N- H3DP40T1N- M3DP40T2N- B3DP4012N- E3DP40T2N- H3DP40T2N- M3DP40T3N- B3DP40T3N- E3DP40T3N- H3DP40T3N- M3

Notes: • Voltages other than above are available.• DP36S1N, T1N and T2N with check terminals are also available.

Specify the illuminationcolor code in the mark.

Red: RGreen: GYellow: YOrange: AWhite: WBlue: SSnow-white: P

X1 X3 X5

X6X4X2

X1X1

X2X2

X1

X2

X1 X1 X1 X1 X1

X2 X2 X2 X2 X2

8

12.8

30 s

q.

36 sq. 618

X1

X2

Panel cutting

Mass: 103gMass: 86g

Mass: 48g

Mass: 114gMass: 96g

Mass: 42g

+0.6–0.5

66 66

+1 035

+1

035

+1 075

+1

035

+0.6–0.5

31+

0.6

–0.5

67

31

+0.

6–0

.531

72

36

618

30

36

8

12.8

36

8

12.8

8

12.8

618

34.5

sq.

40 sq.

80

40

34.5

6183674.5

12.8

8

74.548

8

12.8

• DP36 series

• Square, 36x36mm

• Square, 40x40mm

• Rectangular, 36x72mm

• Rectangular, 40x80mm

• DP40 series

Panel thickness: 1 to 6

Panel thickness: 1 to 6

Panel thickness: 1 to 6

Panel thickness: 1 to 6

Terminal screw M3.5

Terminal screw M3.5

Terminal screw M3.5

Terminal screw M3.5

3-split face type

3-split face type

FUJI ED & C TIMES Vol. 612

New ProductsNew Products

Features• Transparent terminal cover allows the wiring configuration to

be checked externally.• Slotted hexagon head bolts that can be tightened with

screwdrivers or box wrenches are used for the terminals.• The line side and load side are provided with hinged

terminal covers to ensure safety and allow easiermaintenance and inspections.

• cUL approved, file No. E45457 SKT14A-3C to SKT100A3C only.

SKT14A-3C

AF01-220

Power terminal blocksSKT series

Further improving the efficiency and ease of wiringand inspections

Types and ratings

Specifications Tightening torque

Type

SKT14A-3CSKT38A-3CSKT60A-3CSKT100A-3CSKT14A-3CGSKT38A-3CGSKT60A-3CGSKT100A-3CG

Applicable cable size(mm2)2 to 142 to 3814 to 6030 to 1002 to 142 to 3814 to 6030 to 100

Pole

3

3 + 1 (Earth terminal)

Rated insulationvoltage (V AC)

600

600

Rated continuouscurrent (A)

50100150200 50100150200

Insulation resistanceWithstand voltageAmbient temperatureHumidityFlammabilityTemperature rise

100MΩ or more (500V DC megger)2500V AC 1minute-20 to +55°C85%RH or lessUL94V-2 (Cover)45K or less (JIS C 2811)

Type

SKT14A-3CSKT14A-3CGSKT38A-3CSKT38A-3CGSKT60A-3CSKT60A-3CGSKT100A-3CSKT100A-3CG

Load side11.5–15.5

11.5–15.5

11.5–15.5

23–31

(14mm2, M8)

(38mm2, M8)

(60mm2, M8)

(100mm2, M10)

Cable pull-outmin. force (N)

Min. cable222

222

311

311

(2mm2)

(2mm2)

(14mm2)

(30mm2)

Max. cable400

445

623

801

(14mm2)

(38mm2)

(60mm2)

(100mm2)

Line side4.5–5.0

4.5–5.0

9–10

15–20

Recommended tighteningtorque (N•m)

(M6)

(M6)

(M8)

(M10)

• Terminal blocks

• Connectors

Rated continuous current(A) 50100150200400400200

Type

SKT14-SSKT38-SSKT60-SSKT100-SSKT200-SSKT200-SD

Applicable cable size(mm2 )2 to 142 to 3814 to 6030 to 10080 to 20080 to 20030 to 80

Rated insulation voltage(V AC)

600

13FUJI ED & C TIMES Vol. 6

New Products

Dimensions, mm

Power terminal blocks SKT series

• Terminal blockSKT14A-3C (Without earth terminal)SKT14A-3CG (With earth terminal)

SKT38A-3C (Without earth terminal)SKT38A-3CG (With earth terminal)

SKT60A-3C (Without earth terminal)SKT60A-3CG (With earth terminal)

SKT100A-3C (Without earth terminal)SKT100A-3CG (With earth terminal)

• ConnectorSKT14-S SKT38-S SKT60-S

65

24

29.560

252517.5

67

75

32.5

2-ø4.5

M8

M6

94

Earth terminal

80 80

Earth terminal

94

M6

M8

2-ø4.5

32.5

67

17.525 25

6029.5

24

65

75

303023

80

90

24

69

6729.5

34

M8

M8

2-ø5.5

115

Earth terminal

90.5

89

24

29.579

3535

2-ø6.5

115.

5

29

105

43

M10

M10

Earth terminal

135

95

ø4.39M6

53

8

2617

17.2

10

(26) (27)

M8

41.6

max

33.3

1510.314

4

(8.4

)

26.1

53

ø4.39

M8

43.4

max

33.3

17.2

17 26

8M6

4

14 10.315

10

(26) (27)

(8.4

)

27.9

38.1

50.4

max

.

18.81217

M8

ø5.3M8 109

22.8

572919

11.6

(29) (28)

(11.

8)

33.14

SKT100-S SKT200-S SKT200-SD

M10

61.9

max

.46

.2

2315

6.2

4

20

2-ø4.5

M10 1212

27.8

71.53625

6

14.6

(32) (27.5)

(ø13)

(13.

4)

38.2

7

64Mounting hole2-ø6

Mountig hole2-ø6

50 ø14

4862

38.5

6

4

M4 (depth 10)

2-M5 2-M5

6738

30

80 m

ax.

4622

8

2

11

22

34

6450 M10

4862

38.5

6

4

M4 (depth 10)

6738

30

80 m

ax.

46 71.5

max

.

228

2

11

2215

34

48

50 M5

M16 M16

Panel drilling

FUJI ED & C TIMES Vol. 614

New ProductsNew Products

FeaturesFUJI WT2 AC voltage and current transducers convert ACvoltage/current into DC voltage/current, and also isolate input/output circuits and power supplies.

• Select from an 85 to 264V AC, 24V DC, or 110V DC controlpower supply

• Three isolated ports: input, output, and power supply• Use either IEC 35mm rail mounting or screw mounting• Screw terminals with cover ensure safe, sure connection.

AC voltage and current transducersWT2AC series

Isolated AC transducers with a thin profile andexcellent cost performance

Rail mounting Screw mounting

Specifications and performance Input-output• Performance

Accuracy: ±0.4% FSTemperature characteristic: ±0.2%/10°C FS(Typical)Response time: 0.5s max. (0 to 90%)Insulation resistance: 100MΩ (500V DC megger)Withstand voltage: 2000V AC 1min

• Input

• Output

Input signal0 to 110V AC0 to 150V AC0 to 300V AC0 to 1A AC0 to 5A AC

Input frequency50Hz, 60HzVoltage input

Current input

Output signal

0 to 10mV0 to 100mV0 to 1V0 to 5V DC, 1 to 5V DC0 to 10V DC0 to 1mA DC0 to 5mA DC0 to 10mA DC0 to 16mA DC0 to 20mA DC1 to 5mA DC2 to 10mA DC4 to 20mA DC

Permissible externalresistance

10kΩ or more100kΩ or more200kΩ or more1kΩ or more2kΩ or more15kΩ or less3kΩ or less1.5kΩ or less900Ω or less750Ω or less3kΩ or less1.5kΩ or less750Ω or less

Voltage output

Current output

(mA) (mA) (mA) (V)

5

3

1

20

12

4

5

3

1

10

6

2

00000

0.52.5

5575

150

15

110150300

(A)(A)(V)(V)(V)

Input

Out

put

(mA) (mA) (mA) (mA) (mA) (mV) (mV) (V) (V)(V)

20

10

0

16

8

0

10

5

0

5

2.5

0

1

0.5

0

100

50

0

10

5

0

1

0.5

0

5

2.5

0

10

5

0

Input

(A)

(A)

(V)

(V)

(V)

0

0

0

0

0

0.5

2.5

55

75

150

1

5

110

150

300

Out

put

15FUJI ED & C TIMES Vol. 6

New Products AC voltage and current transducers WT2AC series

Dimensions, mm

Wiring diagram

• Rail mounting • Screw mounting

Panel drilling

One-unit mounted n-unit mounted

35mm wide IEC rail

127

Mounting screwM4 x 12Panel

104

97

127

Terminal screwM3.5 x 8

80

25

M4 26 26

26 x (n-1)

97 97

1

3

2

4

Current input

CTLK

k R

1

3

2

4

5

7

6

8

U V

u vVT

Voltage input

Output

Control powersource

(–)

(+)

(–)

(+)

FUJI ED & C TIMES Vol. 616

New ProductsNew Products

Features• Coordinated operation of 2 types of varistors enables

extremely fast response to surges and a high level absorption.• Built-in thermal fuses prevent problems such as short-circuit

due to deterioration of elements.• Indicators for easy confirmation of device status• Integrated terminal construction reduces space and wiring

requirements for easier handling of the arrester.• Standard-feature terminal cover to protect against electrical

shock

Arresters for low voltage circuitCN233 series

Addition of 20kA models absorbing inductivelightning surges from power supply

CN233 series

Specifications

Internal wiring

Application• Electronic devices, such as computers, measurement devices,

and communications devices• Inverters and UPSs• Electronic devices inside distribution boards (e.g., power

distribution boards and lighting distribution boards)

TypeRated voltage

Reference voltageV1ma

Clamping voltageVp

Discharge current(8/20µs)

CN23312Single-phase/2-wire220V420 to 520V610 to 750V1100V min.1500V min.

CN233323-phase/3-wire220V420 to 520V610 to 750V1100V max.1500V max.

Single-phase/3-wire100V/200V

CN2334E3-phase/3-wire440V (Voltage to ground)– 850 to 1100V–2500V max.–20kA (2 times)

CN23311Single-phase/2-wire110V240 to 310V420 to 520V 700V max.1000V max. 5kA (2 times)20kA (2 times)

LineGroundLineGroundLineGround

1/L1F

F

L Z1 E

Z2

Z2

3/L2

1/L1F

F

FL

L Z1 Z1

Z1

E

Z2

Z2

Z2

5/L3

3/L2

1/L1

E

5/L3

3/L2

Z2

Z2

Z2

• CN23311, CN23312

F:Thermal fuse L: Indicator Z1, Z2: Component for surge protective device

• CN23332 • CN2334E

17FUJI ED & C TIMES Vol. 6

New ProductsArresters for low voltage circuit CN233 series

Dimensions, mm

Application example

• Single-phase/2-wire (110AC, 220V AC) • Single-phase/3-wire (100/200V AC)

• 3-phase/3-wire (220V AC) • 3-phase/3-wire (440V AC)

Fuse(AFaC -30 or -60)

Fuse(AFaC-30 or -60)

Fuse(AFaC-30 or -60)

Fuse(AFaC-30 or-60)

1/L1 3/L2

CN23311, 12

E

* Do not wire to the black-colored screw terminal.

1/L1 3/L2

CN23332

E

5/L3

L1NL2

1/L1 3/L2

CN23332

E

5/L3

1/L1 3/L2 5/L3 1/L1 3/L2

CN2324L* CN2334E

Inverter Motor

E

5/L3

2

Mounting plate

120

9575

16 1650

12.5Terminal screw M5

Panel drilling

107

to 1

09

M4

25

35mm wide rail

90

24283

• CN233

FUJI ED & C TIMES Vol. 618

New ProductsNew Products

FeaturesA wide variety of output functions to select from forpreventive maintenance• Power alarm/current prealarm output provided• Electric energy pulse signal provided• Leakage current alarm, leakage current prealarm output

(with leakage current measuring function only)

Capable of measuring inrush current of equipment suchas welders• High-speed sampling and calculation of voltage and current

Compact design allows installation almost anywhere.• Space-saving construction simplifies installation.• Monitors individual equipment, sections, and the entire floor

Networking capability• External interface uses RS-485 communications.• Can be connected to the same electric power distribution

system as other F-MPC (04, 04P, 30, 60B series) products

UM03-ARA3

AC power distribution monitoringunit for one feeder, F-MPC04 series

Digital multimeters – all of the measurement functions forAC power distribution monitoring in a single unit

Types and functions

Specifications

FunctionLeakage current measuring

functionNot providedProvided

TypeUM03-ARA3UM03-ARA3G

• GeneralApplicable circuitControl power supplyInrush current

Control power consumptionShort-time overload resistance

VibrationShockWithstand voltage / Insulation resistance(500V DC megger)

Ambient temperature

HumidityAtmosphereGroundingAllowable power interrupting time

3-phase 3-wire: 2-CT, single-phase 3-wire: 2-CT, single-phase 2-wire: 1-CT100 to 200V AC ( 85 to 264V AC) 50/60Hz (45 to 66Hz)15A, 3ms or less (at 110V AC, 50Hz)30A, 3ms or less (at 220V AC, 50Hz)Approx. 7VA (at 220V AC) Approx. 5VA (at 110V AC)Max. 20 times setting value, 9 times for 0.5sMax. 2 times setting value, 9 times for 0.5s10 to 58Hz 0.075mm (one-way amplitude) 300m/s2, in each X, Y, and Z directions, 2 times2kV /10MΩ Between power supply terminals connected together and other terminals connected together2kV /10MΩ Between measurement input terminals connected together and other terminals connected together2kV /10MΩ Between alarm output terminals connected together and other terminals connected together500V /10MΩ Between watthour pulse output terminals connected together and other terminals connected togetherOperating: -10 to +55˚CStorage: -20 to +70˚C20 to 90%RH (no condensation)Free from corrosive gases and excessive of dustsGrounding resistance of 100Ω or less20ms (unit will continue operation)

Current input circuitVoltage input circuit

System configuration

PC

RS-232CConverter

RS-485

Distribution monitoring unitUM03-ARA3

Equipment

19FUJI ED & C TIMES Vol. 6

New Products

Front panel

AC power distribution monitoring unit for one feeder and CTs

• Terminal layout

• Measurement

ItemCurrent, demand currentMax. demand current valueDemand value and max. demand value of higher harmonic currentDemand active powerMax. demand active power valueReactive powerPower factorActive electric energyReactive electric energyVoltage

FrequencyLeakage current (I/o /Iob) Max. demand value

Effective measurement range• With split toroidal CT (200A AC) * 0, 0.4 % of In (0.8A) to 300A• With split toroidal CT (400A AC) * 0, 0.4% of In (1.6A) to 600A• With small split toroidal CT (5A) * 0, 0.4% of In (0.2A) to 50A 0, to 1.5 times CT rating (for 5A)• Demand time setting: 0, 1 to 15min (by 1min stepped )30min setting: AvailableConverted into an input voltage60 to 264 V AC45 to 66Hz 0, 10 to 1000mA

AccuracyR- and T-phase: ±1.5% FSS-phase: ±2.5% FS± 2.5% FS

±1.5% FS

±3% FS±5% FS Converted into a phase angle of 90˚Equivalent to JIS standard class±5%Vu-v and Vw-u: ±1.5% FS, Vv-w: ±2.5% FS

±0.5% FS±2.5%

Display4-digit

4-digit

4-digit

4-digit3-digit5-digit5-digit4-digit

3-digit4-digit

Note: New model CTs, see page 20.

• Output

ItemWatt-hour pulse outputAlarm output Current prealarm (OCA), power alarm

Leakage current prealarm (OCGA)Leakage current alarm (OCGA)

UM03-ARA3ProvidedProvidedNot provided

UM03-ARA3GProvidedProvidedProvided

SpecificationTransistor open collector output 35V DC 100mAReplay output 250V AC 1A

Dimensions, mm

1

2

3

4COM

OCA

OCGA

OCG

5

6

100-240V AC

ZCT

7

U

V

W

FG

SG

DXA

DXB

8

9

10

13

14

17

18

19

20

19 20

Ir-k

It-k

COM-I

Watt-hourpulse

11

12Alarm output terminals

Measurement voltageinput terminals

Control power inputterminals

Watthour pulse outputterminals

RS-485 communicationterminals

Measurement currentinput terminals

Leakage currentinput terminals

Measurement mode display LEDs

Measurement value, or set value display

Display item, or unit LEDs

Selection switches

2 3

15

16

S(V-W)R(U-V)

T(W-U)

TEST

X1000

X10

X100

SETHISTDEMAND

POWER

kvarhHzcosø kvarA V kWhkW

ALARM

SELECT SET

Note: Alarm output terminal and ZCT input terminal of the UM03-ARA3 (without leakage current measuring function) are NC terminals. Do not connect anything to these terminals.

S(V-W)R(U-V)

T(W-U)

TEST

X1000

X10

X100

SETHISTDEMAND

POWER

kvarhHzcosø kvarA V kWhkW

ALARM

1021248

96107

92+

0.8

0

45 +0.6 0

120

min

.

60 min.Bracket for panel mountingMass: Approx. 400g

Panel cutting

FUJI ED & C TIMES Vol. 620

FeaturesDesigned for even easier handling. Line-up includes typesdesigned specially for FUJI multiple function protectors andcontrollers (F-MPC), and types for use with otherinstrumentation.• Improved design enables easier mounting.• Large K L display allows easier identification of primary

conductor direction.• Hook attached makes it easier to secure the primary

conductor with a retaining band.• Built-in clamping diode (on all types except the CC2D81) CT secondary wiring will not burn out even with the contact

open.

New split toroidal type current transformers/CC2D

CC2D

Types and ratings

Performance

Type

CC2D81-0057

CC2D81-0506

CC2D65-2008

CC2D54-4009

CC2D74-1001CC2D74-2001CC2D74-4001

Ratedprimarycurrent (A)

5

50

200

400

100200400

Ratedsecondarycurrent

7.34mA

73.4mA

66.7mA

133.33mA

1A1A1A

Ratedfrequency(Hz)

50/60

50/60

50/60

50/60

50/60

Rated burden

0.2693mVALoad resistance:5Ω26.93mVALoad resistance:5Ω44.4mVALoad resistance:10Ω or less88.9mVALoad resistance:5Ω or less0.5VALoad resistance:0.5Ω or less

Withstand voltage

1000V AC/1minBetween sensor coreand output1000V AC/1minBetween sensor coreand output2000V AC/1minBetween sensor coreand output2000V AC/1minBetween sensor coreand output2000V AC/1min or moreBetween sensor coreand output

Connection

Heat-resistant IV cableAWG22 x1000mm supplied

Heat-resistant IV cableAWG22 x1000mm supplied

Heat-resistant IV cableAWG18 x1000mm supplied

Heat-resistant IV cableAWG18 x1000mm supplied

Heat-resistant IV cableAWG18 x1000mm supplied

Mass(g)

45

45

200

300

300

Type

CC2D81-0057

CC2D81-0506

CC2D65-2008

CC2D54-4009

CC2D74-1001

CC2D74-2001

CC2D74-4001

Application

For F-MPC

Generalpurpose

Ratio error

±1% In±1.5%/0.2 In

±1% In±1.5%/0.2 In

Phase difference

150' ±150' /In180' ±180' /0.2 In150' ±150' /In180' ±180' /0.2 In±60' /In±90' /0.2 In±60' /In±90' /0.2 In90' ±90' /In120' ±120' /0.2 In60' ±60' /In90' ±90' /0.2 In±80' /In ±100' /0.2 In

Insulation resistance

100MΩ(500V DC megger)

100MΩ(500V DC megger)

Output protection

Not provided

ProvidedBuilt-in clamping diode

Operatingtemperatureand humidity

–20 to +50°C80%RH or lessNo condensation

AC power distribution monitoring unit for one feeder and CTs New Products

21FUJI ED & C TIMES Vol. 6

AC power distribution monitoring unit for one feeder and CTs

Dimensions, mm

• CC2D81 • CC2D65

• CC2D54, CC2D74

1 126 23 13.5

27

3910

00

ø10L K

l (Black) k (White)

Output leadAWG22: 1000mm

Clamp

l (Black)k (White)

451.5 1 4 34 4

22

36 39

64

K Lø24

Output leadAWG18: 1000mm

HookClamp

l (Black)k (White)

ø36

Output leadAWG18: 1000mm

Hook

Clamp

1.5 57 1 4 38 4

22

45 49

80

K L

New Products

FUJI ED & C TIMES Vol. 622

Modified ProductsModified Products

Miniature control relays / HH52, HH54 seriesChange in external terminals

• StandardPlug-in mounting: HH54P, HH54PW, HH52P-RFlange mounting: HH54S, HH54SW, HH52S-R

• High capacityPlug-in mounting: HH54PUFlange mounting: HH54SU

• With extra pick-up coilPlug-in mounting: HH54-2PFlange mounting: HH54-2S

Time of modification: April 2004

Miniature control relays / Sockets for rail mountingChanges in company logo of sockets

Conventional New

• Screw terminal M3 TP58X1: For HH52P TP514X1: For HH54P

Conventional New

New logo

Upper Bottom

TP514X1

Upper

Logo

BottomSide Side

Type number

Name plate Name plate

Time of modification: May 2004

Terminals

Projection

23FUJI ED & C TIMES Vol. 6

Display lights and multi display lights

Change in shape of mounting kit APX111

Conventional New

Time of modification: February 2004

2.8mm3.8mm

Manual motor starters / BM3 series

Change in nameplates on right side

Conventional New

Time of modification: April 2004

• 32AF types: BM3RSBBM3RHBBM3RHBK

• 63AF types: BM3VSBBM3VHBBM3VHBK

Added combined contactor type number conforming to UL508 Type F

Added Tap Conductor Protection

Modified Products

Contact FUJI for details ofsubstituting models.

Further Information

Contact FUJI for details ofsubstituting models.

Further Information

AS-Interface Waterproof connector-type slave module FM6D, FM6B

Substitute

Time of discontinuation: March 2004

Discontinued

AS-Interface Power supply FP1B-JNW213

• For communications/external FP1B-JNW213 Noneaux. power supply

SubstituteDiscontinued

FM6D1-40XXNFM6D1-04TNXFM6D1-22TNN

FM6B1-04FKFM6B1-04FENoneNone

The production of the following products has or will soon be discontinued.Please use substituting models.

Discontinued ProductsDiscontinued Products

Time of discontinuation: February 2004

AS-Interface DeviceNet/AS-i gateway FC2L-DL

• Conversion capsule FC2L-DL FC2LA-DL(Version2.0) (Version2.1)

SubstituteDiscontinued

Time of discontinuation: March 2004

Hardware and software are compatible.

Printed in Japan 2004-3 L25 FISInformation in this catalog is subject to change without notice.

Gate City Ohsaki, East Tower11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan

Phone: +81-3-5435-7135~8Fax: +81-3-5435-7456~9URL http://www.fujielectric.co.jp/fcs/eng

Safety Considerations• For safe operation, before using the product read the instruction manual or user manual that comes with the product carefully or consult the

Fuji sales representative from which you purchased the product.• Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect

human bodies or lives.• Customers, who want to use the products introduced in this catalog for special systems or devices such as for atomic-energy control,

aerospace use, medical use, passenger vehicle, and traffic control, are requested to consult the Fuji sales division.• Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities

that will affect human lives or cause severe damage to property if the products become faulty.• For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or

wiring.

Printed on 100% recycled paper using soy-based ink

• Slaves 4-input (NPN) FM6D-40XXN 4-output (NPN) FM6D-04TNX 2-input/2-output (NPN) FM6D-22TNN

• Slave bases Pressure welding connection FM6B-04FK

FM6B-04FE Screw terminal connection FM6B-04PG

FM6B-04PE