New Products Modified Products Discontinued Products€¦ · 72 84 71 84 83 72 71 54 53 A1 A2 2/T1...
Transcript of New Products Modified Products Discontinued Products€¦ · 72 84 71 84 83 72 71 54 53 A1 A2 2/T1...
TIME006
Vol. 6
Modified ProductsMiniature control relays / HH52, HH54 series ............................................................................................. 22Miniature control relays / Sockets for rail mounting ..................................................................................... 22Display lights and multi display lights .......................................................................................................... 23Manual motor starters / BM3 series ............................................................................................................ 23
Discontinued ProductsAS-Interface Waterproof connector-type slave module FM6D, FM6B....................................................... 24AS-Interface Power supply FP1B-JNW213 .............................................................................................. 24AS-Interface DeviceNet/AS-i gateway FC2L-DL ...................................................................................... 24
New ProductsReversing standard type contactors SC-E series ........................................................................................ 2Manual motor starters Power supply terminal covers .................................................................................. 522mm-dia. emergency stop pushbutton switches AR22 series .................................................................... 622mm-dia. emergency stop pushbutton switches AM22 series ................................................................... 8Display lights DP36 and 40 series ............................................................................................................. 10Power terminal blocks SKT series .............................................................................................................. 12AC voltage and current transducers WT2AC series ................................................................................... 14Arresters for low voltage circuit CN233 series ........................................................................................... 16AC power distribution monitoring unit for one feeder, F-MPC04 series and CC2D CTs ............................. 18
FUJI ED & C TIMES Vol. 62
New ProductsNew Products
Features• Designed for the forward-reverse operation and plugging
stop of 3-phase induction motors.• Mechanical interlock mechanism provided• Snap-on 35mm top hat rail mounting
SC-E3RM
KK03-040
New ProductsNew Products
Reversing standard type contactorsSC-E series
Ideal for reversing 3-phase induction motors
Types and ratings
Reversing contactor Power connection kits
KK03-047
SZ-ERW1/A + SZERW1/B
• AC operated
• DC operated
DC reversing magnetic contactors are also available.
Contact FUJI .
Framesize
E02
E03
E04
E05
E1
E2
E2S
E3
E4
E5E6E7
Motor rating (kW)3-phase (AC-3)200-240V 2.2 3 4 5.5 7.5 11 15 18.5
22
303745
200-240V 9
12
18
25
32
40
50
68
80
105125150
380-440V 9
12
18
25
32
40
50
65
80
105125150
200-240V 20
20
25
32
50
60
65
100
150
150150200
380-440V 20
20
25
32
50
60
65
100
150
150150200
Rated thermal current (A)
20
20
25
32
50
60
65
100
150
150150200
Auxiliary contact arrangement
(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(1NO+1NC) x 2, 2NC x 2(3NO+1NC) x 2, (2NO+2NC) x 2(2NO+2NC) x 2(2NO+2NC) x 2(2NO+2NC) x 2
Type
SC-E02RM *
SC-E03RM *
SC-E04RM *
SC-E05RM *
SC-E1RM *
SC-E2RM *
SC-E2SRM *
SC-E3RM *
SC-E4RM *
SC-E5RM SC-E6RM SC-E7RM
Rated operational current (A)3-phase (AC-3) Resistive load (AC-1)
380-440V 4 5.5 7.5 11 15 18.5 22 30
40
556075
Notes: • Ratings conform to IEC standard• The above types are shipped in a set containing two magnetic contactors,
one SZ-RM mechanical interlock unit, two front mounting auxiliary contact blocks, and electrical interlock wiring. The power connection kit
for the reversing contactor is sold separately.
• To prevent short-circuit faults when using SC-E02RM to SC-E04RM types for high-speed switching, provide a time delay relay or other electrical interlock to ensure that the switching time is 15ms min.* Equipped with the SZ-A11/T, SZ-A02/T, SZ-A31/T, or SZ-A22/T front mounting auxiliary contact block.
Further Information
3FUJI ED & C TIMES Vol. 6
New Products
Dimensions, mm
Reversing standard type contactors SC-E series New Products
• Power connection kits for reversing
SC-E02RM, 03RM, 04RM, 05RM
SC-E1RM, E2RM, E2SRM
SC-E3RM, E4RM
wiring diagrams• AC operated
Power connection kitTypeSZ-ERW1/A (Line side)SZ-ERW1/B (Load side)SZ-ERW1/D (Load side)SZ-ERW2/A (Line side)SZ-ERW2/B (Load side)SZ-ERW2/D (Load side)SZ-ERW3/A (Line side)SZ-ERW3/B (Load side)SZ-ERW3/D (Load side)
Used with
SC-E02 to SC-E05SC-E02/G to SC-E05/G
SC-E1 to E2SSC-E1/G to E2S/G
SC-E3, E4SC-E3/G, E4/G
Power connection kitTypeSZ-ERW4/A (Line side)SZ-ERW4/B (Load side)SZ-ERW5/A (Line side)SZ-ERW5/B (Load side)SZ-ERW6/A (Line side)SZ-ERW6/B (Load side)
Used with
SC-E5
SC-E6
SC-E7
Panel drilling
21 3535
6014
.5
Mounting hole4-M4
8.561
92109
119 (Rail height 15)
Coil terminalM3.5
5699
Main terminal
AuxiliaryterminalM3.5
28
7.710
10.513
4920
81
70.5
Mass: 0.8kg (4-aux. contacts)0.77kg (2-aux. contacts)
Mass: 1.3kg (4-aux. contacts)1.27kg (2-aux. contacts)
Panel drilling
10.5 2
107
124
134 (Rail height 15)
67
121
2245 45
75
67
Mounting hole4-M4
Main terminal
Coil terminalM3.5
AuxiliaryterminalM3.5
9.5
65.5
5718
.5
90
16.5
28
10
7.7
86
Mass: 2.24kg (4-aux. contacts)2.21kg (2-aux. contacts)
Panel drilling
10.5 2.5
72.5
121
139
149 (Rail height 15)
80
147Main terminal
Coil terminalM3.5
AuxiliaryterminalM3.5
(54 to)60 (54 to)60
9013
80
Mounting hole4-M4
28 7719
.511
2
20.57.7
10
108
23
54
53A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
52 62
A2A161 5/L3 3/L2 1/L1 51
2/T1 4/T2 6/T3
A1 A251
52
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
54 62
A2A161 5/L3 3/L2 1/L1 53
2/T1 4/T2 6/T3
A1 A253
54
73
74
83
84
73
74 84
83
83
8472
71
84
83
72
71
54
53A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
(1NO+1NC) x 2
(2NO+2NC) x 2
(3NO+NC) x 2
2NC x 2
FUJI ED & C TIMES Vol. 64
Dimensions, mm
SC-E5RM
SC-E6RM
• SC-E7RM
wiring diagrams• AC operated
Reversing standard type contactors SC-E series New Products
1.6
82
4
137
Mounting hole 3-M5
Auxiliary terminal M3.5
150
7.5
165
111
200
230
Coil terminalM3.5
Main terminal
32
129
10.5
155
Mass : 4.64kg
1.6 4
83
145
175
7.5
190
123
220250
Mounting hole 3-M5 Auxiliary terminal M3.5
Coil terminalM3.5
Main terminal
32
169.
5
143
16
Mass : 5.8kg
2 484
147
200
7.5
215
138260
290
Mounting hole 3-M6
Auxiliary terminal M3.5
Main terminalCoil terminalM3.5
35
146
27
175
Mass : 6.8kg
54
53A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
52 62
A2A161 5/L3 3/L2 1/L1 51
2/T1 4/T2 6/T3
A1 A251
52
2/T1 4/T2 6/T3 62
61 5/L3 3/L2 1/L1
54 62
A2A161 5/L3 3/L2 1/L1 53
2/T1 4/T2 6/T3
A1 A253
54
73
74
83
84
73
74 84
83
83
8472
71
84
83
72
71
54
53A2A1
6/T3 4/T2 2/T1
53 1/L1 3/L2 5/L3 61A1 A2
6254
1/L1 3/L2 5/L3 61
62 6/T3 4/T2 2/T1
(1NO+1NC) x 2
(2NO+2NC) x 2
(3NO+NC) x 2
2NC x 2
5FUJI ED & C TIMES Vol. 6
Dimensions, mm
Features• Combining the BZ0TCRE power supply terminal cover and
BZ0TKUAB short-circuit alarm contact block in a FUJIBM3R series manual motor starter (MMS) allows it to beused as a manual self-protected combination controller(Type E combination motor controller). In the BM3V series,the BZ0TCRE power supply terminal cover is not necessaryto fulfill the UL489 insulation distance requirement.
• Combining the BZ0TCRE power supply terminal cover andBZ0TKUAB short-circuit alarm contact block in acombination starter formed by a BM3R MMS and an SC-series magnetic contactor allows it be used as a self-protected combination controller (Type F combination motorcontroller). In the BM3V series, the BZ0TCRE power supplyterminal cover is not necessary to fulfill the UL489 insulationdistance requirement.
Type E advantages• Since the Type E can be used for branch circuit protection
(BCP) as stipulated in NEC 430.52(c)(6), there is no need toprovide upstream UL489-approved BCPs as short-circuitprotection for motor branching circuits. Ordinarily, aseparate BCP is necessary for each motor.
• It takes up less space inside the control panel. Note: Using Type E to eliminate the need for a BCP applies
only to motor load circuits. It cannot be applied to otherloads, such as resistance load and lamp load circuits.
Power supply terminal coverBZ0TCRE
Manual motor startersPower supply terminal covers
New power supply terminal covers allow UL508Type E and UL508 Type F applications for MMSs
MMS with BZ0TCRE
Type: BZ0TCRE
Type F advantages• By including a compliant MMS in the Type E and applying it
as a BCP as stipulated in NEC 430.52(c)(6), there is noneed to provide upstream UL489-approved BCPs as short-circuit protection for motor branching circuits. Ordinarily, aseparate BCP is necessary for each motor.
• It takes up less space inside the control panel. Note: Using Type F to eliminate the need for a BCP applies
only to motor load circuits. It cannot be applied to otherloads, such as resistance load and lamp load circuits
New ProductsNew Products
10.8
8
10.5
35.5
8
10.5
5.4
13
55.5
45
L1 135 L2L3
1 L1 3 L2 5 L3
3-ø7.5
FUJI ED & C TIMES Vol. 66
New ProductsNew Products
Features• Reliability of safety functions increased by integrated
operator/contact block construction.• LED (24V AC/DC) and neon (110V, 120V, 220V, 240V AC)
illuminated types available, with interconnected lamp circuitthat turns the lamp on when the contacts are closed.
• White arrow on red button clearly indicates push-lock/turn-reset direction.
• Combination of AU-flashed Ag contacts and slidingmechanism ensures high contact reliability.
• Terminal cover for protection degree IP2X increases workersafety by preventing fingers from accidentally touchingcharged parts.
• FUJI original trigger action mechanism stops contacts fromoperating until the button is locked, to prevent accidentalpressing by a person or object.
• Forced contact opening mechanism securely breaks thecircuit even during errors, such as the partial welding of 1NCcontacts.
• Conforms to international standards, including UL/CSA andEN European Standards (TÜV), and bears CE markings.
22mm-dia. emergency stoppushbutton switches AR22 series
Integrated operator/contact block improvesreliability.
• Emergency stop pushbutton switches EN418Forced contact opening and trigger action mechanisms
• Emergency stop illuminated pushbutton switches EN418Forced contact opening and trigger action mechanisms
Contact arrangement1NC1NO+1NC2NC
Button colorRed
TypeAR22VGE-01RAR22VGE-11RAR22VGE-02R
Operator40mm dia.Push-lock, turn-reset
Type of lampLED lampFull-voltage type
Neon lampFull-voltage type
Lamp voltage24V AC/DC
110V AC: H120V AC: K220V AC: M240V AC: P
Contact arrangement1NC1NO+1NC2NC1NC1NO+1NC2NC
Button colorRed
Red
TypeAR22VGF-01E3RAR22VGF-11E3RAR22VGF-02E3RAR22VGF-01 1RAR22VGF-11 1RAR22VGF-02 1R
Operator40mm dia.Push-lock, turn-reset
Note: • Replace the mark by the lamp voltage code. 110V AC: H, 120V AC: K, 220V AC: M, 240V AC: P• Lamp contacts are built-in, and switch operation and lamp circuit are interconnected. When current is applied to the lamp circuit, the lamp turns on as soon as the contacts are colsed.
AR22VGEEmergency stoppushbutton switch
AR22VGFEmergency stopilluminated pushbutton switch
KK03-037 KK03-036
Types and ratings
7FUJI ED & C TIMES Vol. 6
New Products22mm-dia. emergency stop pushbutton switch AR22 series
Dimensions, mm
Specifications
Operating characteristics
Contact ratings
Standards
Rated insulation voltage UiDurability
Operating frequencyWithstand voltageInsulation resistanceVibration
Shock
Ambienttemperature
Humidity (in box)
Operator protectiondegree
Terminal protection degree
250V AC/DCMin. 100000 operationsMin. 100000 operations1800 operations/hour (on-load factor 40%)2500V AC 1minute100MΩ (500V DC megger)Malfunction durability: 10-55Hz double amplitude 0.1mmMechanical durability: 16.7Hz double amplitude 3.0mmMalfunction durability: 150m/s2
Mechanical durability: 500m/s2
-20 to +60°C (Illuminated type: -20 to +50°C)No icing, no condensation-40 to +80°C45 to 85%RH (at -5 to +40°C)No icing, no condensationIEC 60529: IP65JEM 1030: IP65fIEC 60529: IP2X
MechanicalElectrical
Operating
Storage
Ratedoperationalvoltage Ue (V)
24120125240250
Ratedthermalcurrent Ith (A)
10
Rated operational current le (A)ACAC15 (Ind. load)63—3—
DCDC13 (Ind. load)1.5—0.3—0.15
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R500281370001)
Contactrating code
B300
• AC (COSø=0.35)
Contactrating code
Q300
• DC (Time constant T0.95=6P)
120VMake (A)30
Break (A)3
240VMake (A)15
Break (A)1.5
250VMake/Break (A)0.27
125VMake/Break (A)0.55
UL and CSA
OperatorRequired operating forceOperating strokeResetting operation angleRequired resetting force
Push-lock, turn-reset26NApprox. 10mmApprox. 45°Approx. 0.2N•m
UL508CSA C22.2 No. 14EN60947-5-1EN60947-5-5
File No. E44592 (UL Recognized)File No. E44592 (c-UL Recognized)TÜV licence No. R500281370001
43
Terminal No. 2 (12)
Terminal No. 1 (11)
Terminal screw M3.5
Note: Terminal No. shown in ( ) are for contact arrangement 2NC.
Lamp terminal screw M3.5(Illuminated type only)
Terminal No. 3 (21)
ø30
4057 32
55
Terminal No. 4 (22)
Terminal cover
Terminal No. X2
Spring washer
Packing
Panel thickness1 to 6
NutTerminal No. X1
FUJI ED & C TIMES Vol. 68
New ProductsNew Products
Features• White arrow on red button clearly indicates push-lock/turn-
reset direction.• FUJI original trigger action mechanism stops contacts from
operating until the button is locked, to prevent accidentalpressing by a person or object.
• Forced contact opening mechanism securely breaks thecircuit even during errors, such as the partial welding of 1NCcontacts.
• Conforms to international standards, including UL/CSA andEN European Standards (TÜV), and bears CE markings.
22mm-dia. emergency stoppushbutton switches AM22 series
Emergency stop pushbutton switches with lockingnut on the front panel.
AM22V0EEmergency stoppushbutton switch
AM22V0FEmergency stopilluminated pushbutton switch
KK02-236 KK02-240, 239
Types and ratingsEmergency stop pushbutton switches EN418Forced contact opening and trigger action mechanisms
Emergency stop illuminated pushbutton switches EN418Forced contact opening and trigger action mechanisms
Contactarrangement1NC1NO+1NC2NC3NC2NO+2NC4NC1NC1NO+1NC2NC3NC2NO+2NC4NC
ButtoncolorRed
Red
Type
AM22V0E-01RAM22V0E-11RAM22V0E-02RAM22V0E-03RAM22V0E-22RAM22V0E-04RAM22VSE-01RAM22VSE-11RAM22VSE-02RAM22VSE-03RAM22VSE-22RAM22VSE-04R
Operator
40mm dia.Push-lock, turn-reset
29mm dia.Push-lock, turn-reset
Notes: • Up to 4-contact blocks are available.• NO contact is used for overlap contact.
Lampvoltage
Code
Full-voltage6VACA
24VAC/DCE
With transformer110VACH
127VACL
220VACM
254VACQ
380VACS
440VACT
480VACV
550VACW
Trans-former
Without
With
Without
With
Without
With
Lamp voltage
24V AC/DC
110V AC: H220V AC: M
24V AC/DC
110V AC: H220V AC: M
24V AC/DC
110V AC: H220V AC: M
Note: Replace the mark by the lamp voltage code. 110V AC: H, 220V AC: M
Contactarrangement
1NC1NO+1NC2NC3NC1NC1NO+1NC2NC1NC1NO+1NC2NC3NC1NC1NO+1NC2NC1NC1NO+1NC2NC3NC1NC1NO+1NC2NC
Buttoncolor
Red
LED lampType
AM22V0F-01E3RAM22V0F-11E3RAM22V0F-02E3RAM22V0F-03E3RAM22V0F-01 3RAM22V0F-11 3RAM22V0F-02 3RAM22VSF-01E3RAM22VSF-11E3RAM22VSF-02E3RAM22VSF-03E3RAM22VSF-01 3RAM22VSF-11 3RAM22VSF-02 3RAM22VDF-01E3RAM22VDF-11E3RAM22VDF-02E3RAM22VDF-03E3RAM22VDF-01 3RAM22VDF-11 3RAM22VDF-02 3R
Operator
40mm dia.Push-lock,turn-reset
29mm dia.Push-lock,turn-reset
Transparentcolored
40mm dia.Push-lock,turn-reset
• LED lamp voltage
Notes: • 6V AC LED lamp is used for the separate mounting transformer.• NO contact is used for overlap contact.• Switch operation and lamp circuit are not interconnected.
9FUJI ED & C TIMES Vol. 6
New Products22mm-dia. emergency stop pushbutton switch AM22 series
Dimensions, mm
Specifications
Operating characteristics
Contact ratings
Standards
Rated thermal currentRated insulation voltageUiDurability
Operating frequencyWithstand voltageInsulation resistanceVibration
Shock
Ambienttemperature
Humidity (in box)
Operator protectiondegree
10A600V AC/DC(Illuminated full-voltage type 250V AC/DC)Min. 300000 operationsMin. 300000 operations1200 operations/hour (on-load factor 40%)2500V AC 1minute100MΩ (500V DC megger)Malfunction durability: 10-55Hz double amplitude 0.1mmMechanical durability: 16.7Hz double amplitude 3.0mmMalfunction durability: 150m/s2
Mechanical durability: 500m/s2
-20 to +60°C (Illuminated type: -20 to +50°C)No icing, no condensation-40 to +80°C45 to 85%RH (at -5 to +40°C)No icing, no condensationIEC 60529: IP65JEM 1030: IP65f
MechanicalElectrical
Operating
Storage
Rated operational voltageUe (V)
24120125240250480600
Contactratingcode
A600
• AC (COSø=0.35)
Contactratingcode
Q600
• DC (Time constant T0.95=6P)
Rated operational current le (A)ACAC15 (Ind. load)66—6—2.52
DCDC13 (Ind. load)2—0.65—0.23——
120VMake(A)60
Break(A)6
240VMake(A)30
Break(A)3
480VMake(A)15
Break(A)1.5
600VMake(A)12
Break(A)1.2
250VMake/Break(A)0.27
125VMake/Break(A)0.55
300-600VMake/Break(A)0.1
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R50028146)
UL and CSA
OperatorRequired operating forceOperating strokeResetting operation angleRequired resetting force
Push-lock, turn-resetApprox. 23NApprox. 9mmApprox. 60°Approx. 0.25N•m
UL508CSA C22.2 No.14EN 60947-5-1EN 60947-5-5
File No. E 44592 (UL Listed)File No. LR 20479TÜV licence No. R50028146
• 40mm dia. push-lock, turn-reset AM22V0E
• 40mm dia. push-lock, turn-reset with transformer AM22V0F
59.5
44
39.5
32.51
37
ø40
37
Terminal screw M3.5
Panelthickness1 to 6
NutPacking
30
ø16
Terminal cover
Operation angle: 60°
59.5(63.5 *1)
39.5
32.51
44 37 37
24.5
*1
Terminal screw M3.5
Panelthickness1 to 6
NutPacking ø16
30
ø40
Terminal cover
Operation angle: 60°Transformer
Note: *1 Dimensions for the types with transformers of the lamp voltages 254V to 550V AC.
FUJI ED & C TIMES Vol. 610
New ProductsNew Products
Features• Employs high-brightness LED• New LED lamp significantly reduces power consumption and
mass.• Reduces wiring work and improves safety by integrating the
FUJI self-lifting terminal (quick mounting terminal) andterminal cover
• LED lamp incorporates a circuit to prevent lighting errors.• Modular design of LED unit allows easy changes in colors
and color arrangement (two- and three-split rectangularillumination faces).
• Can be used with film legend plates.• Ideal for side-by-side mounting
Display lightsDP36 and 40 series
New design with high-brightness LED and self-liftingterminal improves safety and working conditions.
DP36 seriesKK03-072A
Types and ratings• DP36 series (LED lamp)
Shape of illumination face
Square, 36x36mm
Rectangular, 36x72mm
DP36S1N
DP36T1N
DP36T3N
Illuminationtype
Full face
Full face
2-split face
3-split face
Voltage inputtype
Full voltage
With resistor unit
With CR unit
Full voltage
With resistor unitWith CR unitFull voltage
With resistor unitWith CR unitFull voltage
With resistor unitWith CR unit
Lamp voltage
12V AC/DC24V AC/DC100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC
Type
DP36S1N- B3DP36S1N- E3DP36S1N- H3
DP36S1N- M3
DP36T1N- B3DP36T1N- E3DP36T1N- H3DP36T1N- M3DP36T2N- B3DP3612N- E3DP36T2N- H3DP36T2N- M3DP36T3N- B3DP36T3N- E3DP36T3N- H3DP36T3N- M3
Specify the illuminationcolor code in the mark.
Red: RGreen: GYellow: YOrange: AWhite: WBlue: SSnow-white: P
Notes: • Voltages other than above are available.• DP36S1N, T1N and T2N with check terminals are also available.
11FUJI ED & C TIMES Vol. 6
New ProductsDisplay lights DP36 and 40 series
Dimensions, mm
• DP40 series (LED lamp)
Shape of illumination face
Square, 40x40mm
Rectangular, 40x80mm
DP40S1N
DP40T1N
DP40T3N
Illuminationtype
Full face
Full face
2-split face
3-split face
Voltage inputtype
Full voltage
With resistor unit
With CR unit
Full voltage
With resistor unitWith CR unitFull voltage
With resistor unitWith CR unitFull voltage
With resistor unitWith CR unit
Lamp voltage
12V AC/DC24V AC/DC100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC12V AC/DC24V AC/DC100 to 110V AC/DC200 to 220V AC/DC
Type
DP40S1N- B3DP40S1N- E3DP40S1N- H3
DP40S1N- M3
DP40T1N- B3DP40T1N- E3DP40T1N- H3DP40T1N- M3DP40T2N- B3DP4012N- E3DP40T2N- H3DP40T2N- M3DP40T3N- B3DP40T3N- E3DP40T3N- H3DP40T3N- M3
Notes: • Voltages other than above are available.• DP36S1N, T1N and T2N with check terminals are also available.
Specify the illuminationcolor code in the mark.
Red: RGreen: GYellow: YOrange: AWhite: WBlue: SSnow-white: P
X1 X3 X5
X6X4X2
X1X1
X2X2
X1
X2
X1 X1 X1 X1 X1
X2 X2 X2 X2 X2
8
12.8
30 s
q.
36 sq. 618
X1
X2
Panel cutting
Mass: 103gMass: 86g
Mass: 48g
Mass: 114gMass: 96g
Mass: 42g
+0.6–0.5
66 66
+1 035
+1
035
+1 075
+1
035
+0.6–0.5
31+
0.6
–0.5
67
31
+0.
6–0
.531
72
36
618
30
36
8
12.8
36
8
12.8
8
12.8
618
34.5
sq.
40 sq.
80
40
34.5
6183674.5
12.8
8
74.548
8
12.8
• DP36 series
• Square, 36x36mm
• Square, 40x40mm
• Rectangular, 36x72mm
• Rectangular, 40x80mm
• DP40 series
Panel thickness: 1 to 6
Panel thickness: 1 to 6
Panel thickness: 1 to 6
Panel thickness: 1 to 6
Terminal screw M3.5
Terminal screw M3.5
Terminal screw M3.5
Terminal screw M3.5
3-split face type
3-split face type
FUJI ED & C TIMES Vol. 612
New ProductsNew Products
Features• Transparent terminal cover allows the wiring configuration to
be checked externally.• Slotted hexagon head bolts that can be tightened with
screwdrivers or box wrenches are used for the terminals.• The line side and load side are provided with hinged
terminal covers to ensure safety and allow easiermaintenance and inspections.
• cUL approved, file No. E45457 SKT14A-3C to SKT100A3C only.
SKT14A-3C
AF01-220
Power terminal blocksSKT series
Further improving the efficiency and ease of wiringand inspections
Types and ratings
Specifications Tightening torque
Type
SKT14A-3CSKT38A-3CSKT60A-3CSKT100A-3CSKT14A-3CGSKT38A-3CGSKT60A-3CGSKT100A-3CG
Applicable cable size(mm2)2 to 142 to 3814 to 6030 to 1002 to 142 to 3814 to 6030 to 100
Pole
3
3 + 1 (Earth terminal)
Rated insulationvoltage (V AC)
600
600
Rated continuouscurrent (A)
50100150200 50100150200
Insulation resistanceWithstand voltageAmbient temperatureHumidityFlammabilityTemperature rise
100MΩ or more (500V DC megger)2500V AC 1minute-20 to +55°C85%RH or lessUL94V-2 (Cover)45K or less (JIS C 2811)
Type
SKT14A-3CSKT14A-3CGSKT38A-3CSKT38A-3CGSKT60A-3CSKT60A-3CGSKT100A-3CSKT100A-3CG
Load side11.5–15.5
11.5–15.5
11.5–15.5
23–31
(14mm2, M8)
(38mm2, M8)
(60mm2, M8)
(100mm2, M10)
Cable pull-outmin. force (N)
Min. cable222
222
311
311
(2mm2)
(2mm2)
(14mm2)
(30mm2)
Max. cable400
445
623
801
(14mm2)
(38mm2)
(60mm2)
(100mm2)
Line side4.5–5.0
4.5–5.0
9–10
15–20
Recommended tighteningtorque (N•m)
(M6)
(M6)
(M8)
(M10)
• Terminal blocks
• Connectors
Rated continuous current(A) 50100150200400400200
Type
SKT14-SSKT38-SSKT60-SSKT100-SSKT200-SSKT200-SD
Applicable cable size(mm2 )2 to 142 to 3814 to 6030 to 10080 to 20080 to 20030 to 80
Rated insulation voltage(V AC)
600
13FUJI ED & C TIMES Vol. 6
New Products
Dimensions, mm
Power terminal blocks SKT series
• Terminal blockSKT14A-3C (Without earth terminal)SKT14A-3CG (With earth terminal)
SKT38A-3C (Without earth terminal)SKT38A-3CG (With earth terminal)
SKT60A-3C (Without earth terminal)SKT60A-3CG (With earth terminal)
SKT100A-3C (Without earth terminal)SKT100A-3CG (With earth terminal)
• ConnectorSKT14-S SKT38-S SKT60-S
65
24
29.560
252517.5
67
75
32.5
2-ø4.5
M8
M6
94
Earth terminal
80 80
Earth terminal
94
M6
M8
2-ø4.5
32.5
67
17.525 25
6029.5
24
65
75
303023
80
90
24
69
6729.5
34
M8
M8
2-ø5.5
115
Earth terminal
90.5
89
24
29.579
3535
2-ø6.5
115.
5
29
105
43
M10
M10
Earth terminal
135
95
ø4.39M6
53
8
2617
17.2
10
(26) (27)
M8
41.6
max
33.3
1510.314
4
(8.4
)
26.1
53
ø4.39
M8
43.4
max
33.3
17.2
17 26
8M6
4
14 10.315
10
(26) (27)
(8.4
)
27.9
38.1
50.4
max
.
18.81217
M8
ø5.3M8 109
22.8
572919
11.6
(29) (28)
(11.
8)
33.14
SKT100-S SKT200-S SKT200-SD
M10
61.9
max
.46
.2
2315
6.2
4
20
2-ø4.5
M10 1212
27.8
71.53625
6
14.6
(32) (27.5)
(ø13)
(13.
4)
38.2
7
64Mounting hole2-ø6
Mountig hole2-ø6
50 ø14
4862
38.5
6
4
M4 (depth 10)
2-M5 2-M5
6738
30
80 m
ax.
4622
8
2
11
22
34
6450 M10
4862
38.5
6
4
M4 (depth 10)
6738
30
80 m
ax.
46 71.5
max
.
228
2
11
2215
34
48
50 M5
M16 M16
Panel drilling
FUJI ED & C TIMES Vol. 614
New ProductsNew Products
FeaturesFUJI WT2 AC voltage and current transducers convert ACvoltage/current into DC voltage/current, and also isolate input/output circuits and power supplies.
• Select from an 85 to 264V AC, 24V DC, or 110V DC controlpower supply
• Three isolated ports: input, output, and power supply• Use either IEC 35mm rail mounting or screw mounting• Screw terminals with cover ensure safe, sure connection.
AC voltage and current transducersWT2AC series
Isolated AC transducers with a thin profile andexcellent cost performance
Rail mounting Screw mounting
Specifications and performance Input-output• Performance
Accuracy: ±0.4% FSTemperature characteristic: ±0.2%/10°C FS(Typical)Response time: 0.5s max. (0 to 90%)Insulation resistance: 100MΩ (500V DC megger)Withstand voltage: 2000V AC 1min
• Input
• Output
Input signal0 to 110V AC0 to 150V AC0 to 300V AC0 to 1A AC0 to 5A AC
Input frequency50Hz, 60HzVoltage input
Current input
Output signal
0 to 10mV0 to 100mV0 to 1V0 to 5V DC, 1 to 5V DC0 to 10V DC0 to 1mA DC0 to 5mA DC0 to 10mA DC0 to 16mA DC0 to 20mA DC1 to 5mA DC2 to 10mA DC4 to 20mA DC
Permissible externalresistance
10kΩ or more100kΩ or more200kΩ or more1kΩ or more2kΩ or more15kΩ or less3kΩ or less1.5kΩ or less900Ω or less750Ω or less3kΩ or less1.5kΩ or less750Ω or less
Voltage output
Current output
(mA) (mA) (mA) (V)
5
3
1
20
12
4
5
3
1
10
6
2
00000
0.52.5
5575
150
15
110150300
(A)(A)(V)(V)(V)
Input
Out
put
(mA) (mA) (mA) (mA) (mA) (mV) (mV) (V) (V)(V)
20
10
0
16
8
0
10
5
0
5
2.5
0
1
0.5
0
100
50
0
10
5
0
1
0.5
0
5
2.5
0
10
5
0
Input
(A)
(A)
(V)
(V)
(V)
0
0
0
0
0
0.5
2.5
55
75
150
1
5
110
150
300
Out
put
15FUJI ED & C TIMES Vol. 6
New Products AC voltage and current transducers WT2AC series
Dimensions, mm
Wiring diagram
• Rail mounting • Screw mounting
Panel drilling
One-unit mounted n-unit mounted
35mm wide IEC rail
127
Mounting screwM4 x 12Panel
104
97
127
Terminal screwM3.5 x 8
80
25
M4 26 26
26 x (n-1)
97 97
1
3
2
4
Current input
CTLK
k R
1
3
2
4
5
7
6
8
U V
u vVT
Voltage input
Output
Control powersource
(–)
(+)
(–)
(+)
FUJI ED & C TIMES Vol. 616
New ProductsNew Products
Features• Coordinated operation of 2 types of varistors enables
extremely fast response to surges and a high level absorption.• Built-in thermal fuses prevent problems such as short-circuit
due to deterioration of elements.• Indicators for easy confirmation of device status• Integrated terminal construction reduces space and wiring
requirements for easier handling of the arrester.• Standard-feature terminal cover to protect against electrical
shock
Arresters for low voltage circuitCN233 series
Addition of 20kA models absorbing inductivelightning surges from power supply
CN233 series
Specifications
Internal wiring
Application• Electronic devices, such as computers, measurement devices,
and communications devices• Inverters and UPSs• Electronic devices inside distribution boards (e.g., power
distribution boards and lighting distribution boards)
TypeRated voltage
Reference voltageV1ma
Clamping voltageVp
Discharge current(8/20µs)
CN23312Single-phase/2-wire220V420 to 520V610 to 750V1100V min.1500V min.
CN233323-phase/3-wire220V420 to 520V610 to 750V1100V max.1500V max.
Single-phase/3-wire100V/200V
CN2334E3-phase/3-wire440V (Voltage to ground)– 850 to 1100V–2500V max.–20kA (2 times)
CN23311Single-phase/2-wire110V240 to 310V420 to 520V 700V max.1000V max. 5kA (2 times)20kA (2 times)
LineGroundLineGroundLineGround
1/L1F
F
L Z1 E
Z2
Z2
3/L2
1/L1F
F
FL
L Z1 Z1
Z1
E
Z2
Z2
Z2
5/L3
3/L2
1/L1
E
5/L3
3/L2
Z2
Z2
Z2
• CN23311, CN23312
F:Thermal fuse L: Indicator Z1, Z2: Component for surge protective device
• CN23332 • CN2334E
17FUJI ED & C TIMES Vol. 6
New ProductsArresters for low voltage circuit CN233 series
Dimensions, mm
Application example
• Single-phase/2-wire (110AC, 220V AC) • Single-phase/3-wire (100/200V AC)
• 3-phase/3-wire (220V AC) • 3-phase/3-wire (440V AC)
Fuse(AFaC -30 or -60)
Fuse(AFaC-30 or -60)
Fuse(AFaC-30 or -60)
Fuse(AFaC-30 or-60)
1/L1 3/L2
CN23311, 12
E
* Do not wire to the black-colored screw terminal.
1/L1 3/L2
CN23332
E
5/L3
L1NL2
1/L1 3/L2
CN23332
E
5/L3
1/L1 3/L2 5/L3 1/L1 3/L2
CN2324L* CN2334E
Inverter Motor
E
5/L3
2
Mounting plate
120
9575
16 1650
12.5Terminal screw M5
Panel drilling
107
to 1
09
M4
25
35mm wide rail
90
24283
• CN233
FUJI ED & C TIMES Vol. 618
New ProductsNew Products
FeaturesA wide variety of output functions to select from forpreventive maintenance• Power alarm/current prealarm output provided• Electric energy pulse signal provided• Leakage current alarm, leakage current prealarm output
(with leakage current measuring function only)
Capable of measuring inrush current of equipment suchas welders• High-speed sampling and calculation of voltage and current
Compact design allows installation almost anywhere.• Space-saving construction simplifies installation.• Monitors individual equipment, sections, and the entire floor
Networking capability• External interface uses RS-485 communications.• Can be connected to the same electric power distribution
system as other F-MPC (04, 04P, 30, 60B series) products
UM03-ARA3
AC power distribution monitoringunit for one feeder, F-MPC04 series
Digital multimeters – all of the measurement functions forAC power distribution monitoring in a single unit
Types and functions
Specifications
FunctionLeakage current measuring
functionNot providedProvided
TypeUM03-ARA3UM03-ARA3G
• GeneralApplicable circuitControl power supplyInrush current
Control power consumptionShort-time overload resistance
VibrationShockWithstand voltage / Insulation resistance(500V DC megger)
Ambient temperature
HumidityAtmosphereGroundingAllowable power interrupting time
3-phase 3-wire: 2-CT, single-phase 3-wire: 2-CT, single-phase 2-wire: 1-CT100 to 200V AC ( 85 to 264V AC) 50/60Hz (45 to 66Hz)15A, 3ms or less (at 110V AC, 50Hz)30A, 3ms or less (at 220V AC, 50Hz)Approx. 7VA (at 220V AC) Approx. 5VA (at 110V AC)Max. 20 times setting value, 9 times for 0.5sMax. 2 times setting value, 9 times for 0.5s10 to 58Hz 0.075mm (one-way amplitude) 300m/s2, in each X, Y, and Z directions, 2 times2kV /10MΩ Between power supply terminals connected together and other terminals connected together2kV /10MΩ Between measurement input terminals connected together and other terminals connected together2kV /10MΩ Between alarm output terminals connected together and other terminals connected together500V /10MΩ Between watthour pulse output terminals connected together and other terminals connected togetherOperating: -10 to +55˚CStorage: -20 to +70˚C20 to 90%RH (no condensation)Free from corrosive gases and excessive of dustsGrounding resistance of 100Ω or less20ms (unit will continue operation)
Current input circuitVoltage input circuit
System configuration
PC
RS-232CConverter
RS-485
Distribution monitoring unitUM03-ARA3
Equipment
19FUJI ED & C TIMES Vol. 6
New Products
Front panel
AC power distribution monitoring unit for one feeder and CTs
• Terminal layout
• Measurement
ItemCurrent, demand currentMax. demand current valueDemand value and max. demand value of higher harmonic currentDemand active powerMax. demand active power valueReactive powerPower factorActive electric energyReactive electric energyVoltage
FrequencyLeakage current (I/o /Iob) Max. demand value
Effective measurement range• With split toroidal CT (200A AC) * 0, 0.4 % of In (0.8A) to 300A• With split toroidal CT (400A AC) * 0, 0.4% of In (1.6A) to 600A• With small split toroidal CT (5A) * 0, 0.4% of In (0.2A) to 50A 0, to 1.5 times CT rating (for 5A)• Demand time setting: 0, 1 to 15min (by 1min stepped )30min setting: AvailableConverted into an input voltage60 to 264 V AC45 to 66Hz 0, 10 to 1000mA
AccuracyR- and T-phase: ±1.5% FSS-phase: ±2.5% FS± 2.5% FS
±1.5% FS
±3% FS±5% FS Converted into a phase angle of 90˚Equivalent to JIS standard class±5%Vu-v and Vw-u: ±1.5% FS, Vv-w: ±2.5% FS
±0.5% FS±2.5%
Display4-digit
4-digit
4-digit
4-digit3-digit5-digit5-digit4-digit
3-digit4-digit
Note: New model CTs, see page 20.
• Output
ItemWatt-hour pulse outputAlarm output Current prealarm (OCA), power alarm
Leakage current prealarm (OCGA)Leakage current alarm (OCGA)
UM03-ARA3ProvidedProvidedNot provided
UM03-ARA3GProvidedProvidedProvided
SpecificationTransistor open collector output 35V DC 100mAReplay output 250V AC 1A
Dimensions, mm
1
2
3
4COM
OCA
OCGA
OCG
5
6
100-240V AC
ZCT
7
U
V
W
FG
SG
DXA
DXB
8
9
10
13
14
17
18
19
20
19 20
Ir-k
It-k
COM-I
Watt-hourpulse
11
12Alarm output terminals
Measurement voltageinput terminals
Control power inputterminals
Watthour pulse outputterminals
RS-485 communicationterminals
Measurement currentinput terminals
Leakage currentinput terminals
Measurement mode display LEDs
Measurement value, or set value display
Display item, or unit LEDs
Selection switches
2 3
15
16
S(V-W)R(U-V)
T(W-U)
TEST
X1000
X10
X100
SETHISTDEMAND
POWER
kvarhHzcosø kvarA V kWhkW
ALARM
SELECT SET
Note: Alarm output terminal and ZCT input terminal of the UM03-ARA3 (without leakage current measuring function) are NC terminals. Do not connect anything to these terminals.
S(V-W)R(U-V)
T(W-U)
TEST
X1000
X10
X100
SETHISTDEMAND
POWER
kvarhHzcosø kvarA V kWhkW
ALARM
1021248
96107
92+
0.8
0
45 +0.6 0
120
min
.
60 min.Bracket for panel mountingMass: Approx. 400g
Panel cutting
FUJI ED & C TIMES Vol. 620
FeaturesDesigned for even easier handling. Line-up includes typesdesigned specially for FUJI multiple function protectors andcontrollers (F-MPC), and types for use with otherinstrumentation.• Improved design enables easier mounting.• Large K L display allows easier identification of primary
conductor direction.• Hook attached makes it easier to secure the primary
conductor with a retaining band.• Built-in clamping diode (on all types except the CC2D81) CT secondary wiring will not burn out even with the contact
open.
New split toroidal type current transformers/CC2D
CC2D
Types and ratings
Performance
Type
CC2D81-0057
CC2D81-0506
CC2D65-2008
CC2D54-4009
CC2D74-1001CC2D74-2001CC2D74-4001
Ratedprimarycurrent (A)
5
50
200
400
100200400
Ratedsecondarycurrent
7.34mA
73.4mA
66.7mA
133.33mA
1A1A1A
Ratedfrequency(Hz)
50/60
50/60
50/60
50/60
50/60
Rated burden
0.2693mVALoad resistance:5Ω26.93mVALoad resistance:5Ω44.4mVALoad resistance:10Ω or less88.9mVALoad resistance:5Ω or less0.5VALoad resistance:0.5Ω or less
Withstand voltage
1000V AC/1minBetween sensor coreand output1000V AC/1minBetween sensor coreand output2000V AC/1minBetween sensor coreand output2000V AC/1minBetween sensor coreand output2000V AC/1min or moreBetween sensor coreand output
Connection
Heat-resistant IV cableAWG22 x1000mm supplied
Heat-resistant IV cableAWG22 x1000mm supplied
Heat-resistant IV cableAWG18 x1000mm supplied
Heat-resistant IV cableAWG18 x1000mm supplied
Heat-resistant IV cableAWG18 x1000mm supplied
Mass(g)
45
45
200
300
300
Type
CC2D81-0057
CC2D81-0506
CC2D65-2008
CC2D54-4009
CC2D74-1001
CC2D74-2001
CC2D74-4001
Application
For F-MPC
Generalpurpose
Ratio error
±1% In±1.5%/0.2 In
±1% In±1.5%/0.2 In
Phase difference
150' ±150' /In180' ±180' /0.2 In150' ±150' /In180' ±180' /0.2 In±60' /In±90' /0.2 In±60' /In±90' /0.2 In90' ±90' /In120' ±120' /0.2 In60' ±60' /In90' ±90' /0.2 In±80' /In ±100' /0.2 In
Insulation resistance
100MΩ(500V DC megger)
100MΩ(500V DC megger)
Output protection
Not provided
ProvidedBuilt-in clamping diode
Operatingtemperatureand humidity
–20 to +50°C80%RH or lessNo condensation
AC power distribution monitoring unit for one feeder and CTs New Products
21FUJI ED & C TIMES Vol. 6
AC power distribution monitoring unit for one feeder and CTs
Dimensions, mm
• CC2D81 • CC2D65
• CC2D54, CC2D74
1 126 23 13.5
27
3910
00
ø10L K
l (Black) k (White)
Output leadAWG22: 1000mm
Clamp
l (Black)k (White)
451.5 1 4 34 4
22
36 39
64
K Lø24
Output leadAWG18: 1000mm
HookClamp
l (Black)k (White)
ø36
Output leadAWG18: 1000mm
Hook
Clamp
1.5 57 1 4 38 4
22
45 49
80
K L
New Products
FUJI ED & C TIMES Vol. 622
Modified ProductsModified Products
Miniature control relays / HH52, HH54 seriesChange in external terminals
• StandardPlug-in mounting: HH54P, HH54PW, HH52P-RFlange mounting: HH54S, HH54SW, HH52S-R
• High capacityPlug-in mounting: HH54PUFlange mounting: HH54SU
• With extra pick-up coilPlug-in mounting: HH54-2PFlange mounting: HH54-2S
Time of modification: April 2004
Miniature control relays / Sockets for rail mountingChanges in company logo of sockets
Conventional New
• Screw terminal M3 TP58X1: For HH52P TP514X1: For HH54P
Conventional New
New logo
Upper Bottom
TP514X1
Upper
Logo
BottomSide Side
Type number
Name plate Name plate
Time of modification: May 2004
Terminals
Projection
23FUJI ED & C TIMES Vol. 6
Display lights and multi display lights
Change in shape of mounting kit APX111
Conventional New
Time of modification: February 2004
2.8mm3.8mm
Manual motor starters / BM3 series
Change in nameplates on right side
Conventional New
Time of modification: April 2004
• 32AF types: BM3RSBBM3RHBBM3RHBK
• 63AF types: BM3VSBBM3VHBBM3VHBK
Added combined contactor type number conforming to UL508 Type F
Added Tap Conductor Protection
Modified Products
Contact FUJI for details ofsubstituting models.
Further Information
Contact FUJI for details ofsubstituting models.
Further Information
AS-Interface Waterproof connector-type slave module FM6D, FM6B
Substitute
Time of discontinuation: March 2004
Discontinued
AS-Interface Power supply FP1B-JNW213
• For communications/external FP1B-JNW213 Noneaux. power supply
SubstituteDiscontinued
FM6D1-40XXNFM6D1-04TNXFM6D1-22TNN
FM6B1-04FKFM6B1-04FENoneNone
The production of the following products has or will soon be discontinued.Please use substituting models.
Discontinued ProductsDiscontinued Products
Time of discontinuation: February 2004
AS-Interface DeviceNet/AS-i gateway FC2L-DL
• Conversion capsule FC2L-DL FC2LA-DL(Version2.0) (Version2.1)
SubstituteDiscontinued
Time of discontinuation: March 2004
Hardware and software are compatible.
Printed in Japan 2004-3 L25 FISInformation in this catalog is subject to change without notice.
Gate City Ohsaki, East Tower11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan
Phone: +81-3-5435-7135~8Fax: +81-3-5435-7456~9URL http://www.fujielectric.co.jp/fcs/eng
Safety Considerations• For safe operation, before using the product read the instruction manual or user manual that comes with the product carefully or consult the
Fuji sales representative from which you purchased the product.• Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect
human bodies or lives.• Customers, who want to use the products introduced in this catalog for special systems or devices such as for atomic-energy control,
aerospace use, medical use, passenger vehicle, and traffic control, are requested to consult the Fuji sales division.• Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities
that will affect human lives or cause severe damage to property if the products become faulty.• For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or
wiring.
Printed on 100% recycled paper using soy-based ink
• Slaves 4-input (NPN) FM6D-40XXN 4-output (NPN) FM6D-04TNX 2-input/2-output (NPN) FM6D-22TNN
• Slave bases Pressure welding connection FM6B-04FK
FM6B-04FE Screw terminal connection FM6B-04PG
FM6B-04PE