NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different...

8
NEW AIR DOOR RANGE AIR CONDITIONING www.vortice.com

Transcript of NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different...

Page 1: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

NEW

AIR DOOR RANGEAIR CONDITIONING

www.vortice.com

Page 2: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

www.vortice.com

Page 3: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

3

Vortice has achieved European market leadershipby dedicating their efforts to the productionof products for ventilation, climate control, heating, extraction, purification and the treatment of air,for domestic, commercial and industrial applications. Since 1954 Vortice has been synonymous with quality and excellence and continues to make significant improvements by investing in continuous research to improve the efficiency and qualityof its products.

Vortice main company’s philosopy is the concept that “air is our life”. Our mission is alwaysto provide effective solutions for improved air quality using the latest technology to develop and manufacture effective products worldwide.

Our current Vortice Headquarters have been located in Tribiano (Milan) since 1972.

VORTICE IN THE WORLD

Founded in 1974,Vortice France is locatedat Crétail about 10 Kmfrom Paris.

Founded in 1977,Vortice Limitedis located at Burton on Trent in the East Midlands.

Founded in 2012,Vortice Ventilation Systemis located about 200 Kmfrom Shanghai.

Founded in 2012,Vortice Latam in San Josè Costarica.

HEADQUARTERS

Page 4: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

4

Air curtains, installed in line with doors or openings in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter, in order to stop heat from being transferred from one environment to another while preventing pollutants (e.g., dust, exhaust gases, smoke, odours) and insects coming in from outdoors.The air curtains allow customers to enter and leave freely, without obstructing the passageway and providing maximum visibility into the room.The barriers can also be used inside the building, to separate rooms with different conditions: for example, heated areas and unheated warehouses, or dining rooms and kitchens; this facilitates the transit of staff and prevents odours and vapours from being transferred.

• Elegantanddistinctiveaesthetics.• Highperformance(upto2,700m3/h).• Highspeedofairflow(11m/sstandardmodels,9,5m/s. models equipped with heating elements), granting an effective action up to 4 m high installation.• Greatinstallationflexibility:frontintakegrillesallowAIRDOOR mounting close to the ceiling even in low ceiling rooms (minimum 2,30 m).• Easyandquickinstallation,thankstothepracticalwallmountingbracket.• Possibilityoninstallationinseries,tocoverlongwidthopenings.

Key features

AIR DOOR RANGEAir curtains for horizontal installation, particularly suitable for use in public places

Elegant design and environmental comfort

Page 5: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

5

AIR DOOR RANGE

• Foodindustry,whereclimaticandhygienicseparation is required between departments, alongside the quick and easy passage of goods and people;• Hospitalsandlaboratories;• Cateringandhospitality(kitchenodoursarekeptaway from dining rooms);• Offices,schools;• Cinemas,bookshops;• Warehousesandmanufacturingdepartments;• Bars,restaurants,icecreamparlours;• Supermarkets;• Banks;• Swimmingpools,sportscentres,changingrooms;• Refrigeratedunits(outdoormounting);• Greenhouses,dryingrooms.

Application types

0 m

1 m

2 m

3 m

8-11.5 m/s

4-5 m/s

3-4.5 m/s

2-3.5 m/s

4 m

velocità dell’aria

• Minimuminstallationheight:2.3m.• Maximumrecommendedinstallationheight:4m.• Horizontalwallinstallation,abovedoorsorascloseaspossibletothe opening, to prevent the passage of air at the sides.• Thereisnoneedtoleavespacebetweenthecurtainandtheceiling,as models with a front air intake grille do not require this. • Thesecurtainscanalsobeusedforinstallationswithlimitedspace.• Easytoinstallbymeansofapracticalwallmountingbracket.

Installation

min

2.3

m

max

4 m

over

4 m

YES

YESNO

NO

Air speed

Page 6: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

AIR CONDITIONING

6

Provide appreciable cost savings related to heating (in winter) and cooling (in summer). Installed in correspondence of doors and, more generally, of access areas, AIR DOOR units generate an air stream hindering the entry of external air at unpleasent temperature. Particularly suitable also to prevent entry of smoke, smog, insects and avoid spread of odors between adjoining rooms.

8 models for different lengths (900 mm, 1200 mm, 1500 mm and 2000), power supplies (single or three phase), available features and benefits paid. Cross-flow fans, ensuring low noise levels, driven by asynchronous, double-shaft, two speed motors for the best compromise between performance, temperature of generated air flow (models equipped with heating elements), and output sound level. Front panels in brushed aluminum (silver grey color), integrating intake grille; rear panels in black painted sheet metal; side panels in black thermoplastic resin. Adjustable flaps; mounted in correspondence of exhaust, allow to direct outgoing airstream as desired.

Infraredremotecontrolallowing: -ON/Offswitching - Selection of desired operation speed -HeatingelementsswitchOn/Off(AIRDOORHmodelsonly) Commands are replicated on board. A lamp on the front panel shows the product status. OnlyformodelsAIRDOORH,heatingelementsconsistingofPTCthermistorsoffering high thermal performance and reduced drag, protected against overheating and voltage peaks. A peculiar logic of operation, delaying the fan stop after the battery switch off, contributes to its reliable operation over time. Possibility of coupling with standard door sensors on the market. Insulationclass:I. .

AIR DOOR RANGEAir curtains for horizontal installation, particularly suitablefor use in public places

Infrared remote control Commands are replicated on board

ErP

PRODUCT SPECIFICATIONS

Page 7: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

7

AIR DOOR RANGE

DIMENSIONS

Models A B C

AIR DOOR AD 900 900

220 190AIR DOOR AD 1200 1200

AIR DOOR AD 1500 1500

AIR DOOR AD 2000 2000

AIR DOOR H AD 900 M 950

305 235

AIR DOOR H AD 900 T 950

AIR DOOR H AD 1200 T 1230

AIR DOOR H AD 1500 T 1510

Dimensions(mm)

AC

B

TECHNICAL DATA

Models Code V HzFan Powermin./max.

W

Heating Powermin./mid./max.

kW

Airflowmin./max

m3/h

Air Speedmin./max.

m/s

Noisemin./max.

dBKg

AIR DOOR AD 900 65195

230

50

110/160 - 1100/1400

9/11

55/57 10

AIR DOOR AD 1200 65196 150/200 - 1600/1900 56/58 12.5

AIR DOOR AD 1500 65197 180/230 - 2000/2500 57/59 15.5

AIR DOOR AD 2000 65198 300/350 - 2900/3600 59/61 20.5

AIR DOOR H AD 900 M 65155 110/160 2/4/6 1000/1200

8,5/9,5

55/57 13.5

AIR DOOR H AD 900 T 65156

380

110/160 2/4/6 1000/1200 55/57 13.5

AIR DOOR H AD 1200 T 65157 150/200 4/6/8 1500/1700 56/58 16

AIR DOOR AD H 1500 T 65158 180/230 6/8/10 1900/2200 57/59 18.5

Page 8: NEW - airtechnic.gr · in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter,

Conforms to the standards:EN60335-1,EN60335-2-80,EN60529,EN62233Performance checked according to:CEI107-53/1986(EN13-4:2004)

EMC:EN55014–1,EN55014-2,EN61000-3-2,EN60555-1European Directives for CE mark:LowVoltageDirective(2006/95/CE)

Directive on Electromagnetic Compatibility: (2004/108/CE)

The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristcs of the models described and illustred, to modify products whenever necessary and without warning.

Vortice Elettrosociali S.p.AStrada Cerca, 2Frazione di Zoate20067 Tribiano (Milano)Tel. (+39) 02 906991Fax (+39) 02 90699 [email protected]

Vortice LimitedBeeches House-Eastern AvenueBurton on Trent DE13 0BBTel. (+44) 1283-49.29.49Fax (+44) 1283-54.41.21United [email protected]

Vortice France15-33, Rue Le CorbusierCS 3000794046 Créteil CedexTél. (+33) 1.55.12.50.00Fax (+33) 1.55.12.50.01 [email protected]

Cod. 5.170.084.666 07/15

Μιχαήλ Καραολή 19 143 43, Ν. Χαλκηδόνα, ΑθήναΤηλ: 211 - 70.55.500 & 210 - 21.30.051, Fax: 210 - 22.23.283