Neutron Imaging Detector Based on the µPIC Micro-Pixel ... · 1. Introduction We have developed a...

1
1. Introduction We have developed a prototype neutron imaging detector which employs the micro-pixel gaseous chamber (μPIC), a micropattern gaseous detector, coupled with a field programmable gate array (FPGA)-based data acquisition system for applications in small-angle neutron scattering and radiography at high-intensity neutron sources [1-3]. Features of our μPIC-based detector Gas mixture of Ar-C 2 H 6 - 3 He (63:7:30) at 2 atm (current prototype). Large energy release for n+ 3 He reaction (764 keV) requires low gas gain of <1000 (excellent stability against discharge). Detection efficiency up to 30% for thermal neutrons. Remains operable for more than 1 year on a single gas filling. Compact FPGA-based data acquisition system capable of high data rates (~10 MHz). Good spatial and time resolutions of <120 μm and ~1 μs, respectively. Strong rejection of gamma background (effective gamma sensitivity of <10 -9 ). The μPIC is available in sizes up to 30 × 30 cm 2 (larger areas accommodated by tiling). 2. Prototype detector The prototype detector uses a time projection chamber (TPC) consisting of an aluminum drift plane, drift cage, and a 10 × 10 cm 2 μPIC. This TPC is contained within a 1-cm thick aluminum vessel that can accommodate drift heights up to 5 cm and is capable of withstanding pressures up to 2 atm. The μPIC itself was developed in our group at Kyoto University [4] and is manufactured by DaiNippon Printing Co., Ltd., using inexpensive printed circuit board (PCB) technology. 3. FPGA encoder logic The heart of the data acquisition system (DAQ) is the FPGA encoder module [6]. The version of the FPGA firmware used for neutron imaging is known as X-ray mode 8. In this mode, all incoming data is streamed to the VME memory with no per-event trigger, and the individual events are later isolated in the offline analysis using a clustering algorithm. Additionally, by recording both the leading and trailing edge of the signals (new for mode 8), we are able to estimated the energy deposition using the time-above-threshold (TAT) method with no added cost or complexity for the DAQ. 4. Detector performance To study the performance of our prototype detector, three test experiments were carried out at the Japan Spallation Neutron Source (JSNS) located at the Japan Proton Accelerator Research Facility (J-PARC) in Tokai, Japan. The JSNS delivers a 25-Hz pulsed neutron beam to a total of 23 beam ports. Our measurements were carried out at NOBORU (NeutrOn Beamline for Observation and Research) [7], at beamline 10. The experiments were performed in Nov. 2009, June 2010, and Feb. 2011. Results for the first two experiments were reported in Refs. [2,3]. Additional tests were performed at our laboratory using various radioisotope sources. For all of the measurements described below, the detector was filled with a gas mixture of Ar-C 2 H 6 - 3 He (63:7:30) at 2 atm. 4.1. Neutron-gamma separation Neutron-gamma separation is achieved by combining information about the energy deposition (via time-above-threshold) and track length. Neutrons produce proton-triton tracks with essentially the same energy and track lengths, while gamma events deposit much less energy and produce a range of track lengths. The gamma rejection capability of the prototype was studied using a 1-MBq 137 Cs source, which produces gamma-rays at an energy of 662 keV. 4.2. Position resolution To determine the neutron interaction position for a particular event, we need to know two things: 1) the width of the track in x and y, and 2) the proton direction (both are determined from the shape of the TAT distribution). Once these are known, a correction can be made from the mid-point of the track to the estimated neutron interaction position. The position resolution was studied at NOBORU in Feb. 2011 using a cadmium test chart with a slit pattern consisting of 0.5-mm slits at a pitch of 5 mm. The detector was placed in the neutron beam at distance of 14.5 m from the moderator, and the test chart was attached directly to the front of the vessel. 4.3. Long-term operability At a time when the global demand for 3 He is outstripping the world’s supply [8], it is important to minimize the 3 He usage of our detector. In our sealed detector, the build-up of impurities over time leads to a degradation in the properties of the gas. Thus, to maintain the desired gas properties, the detector must be periodically evacuated and refilled. Over the course of testing, we found that the detector remained operable for more than one year on a single gas filling. Several strategies can be employed to further increase the time between gas fillings: 1) annealing of the vessel and μPIC to reduce outgassing, and 2) a gas filtration system to remove any impurities that build up in the gas. If these are realized, the operation cycle of the detector could be extended almost indefinitely, greatly reducing maintenance costs related to 3 He gas. 5. Demonstration measurements Several demonstration measurements were made at NOBORU in Nov. 2009 (SANS) and Feb. 2011 (resonance absorption, Bragg-edge transmission). 6. Future improvements Currently, efforts to optimize the gas mixture for improved position resolution of the detector are underway. For instance, by switching the quencher gas to CO 2 , we expect diffusion to be greatly reduced, resulting in a position resolution of ~100 μm (estimated using MAGBOLTZ and GEANT4). Further reductions can be obtained by reducing the pixel pitch of the μPIC. By rearranging the anode pixels (dense packing), we can reduce the pixel pitch, and, thereby, improve the position resolution, by as much as another 30%. For the DAQ, an ultra-compact encoder, which combines new low-power discriminator chips and an FPGA on a single board, has recently been developed in our group. In addition to significantly reducing the bulk of the system, the new encoder is expected to achieve data rates about 5 times higher than the current encoder system. 7. Conclusion By measuring both the energy deposition (via time-above-threshold) and track positions, a position resolution of <120 μm and an effective gamma sensitivity of <10 -9 were achieved. The time resolution of ~1 μs, as determined by the electron drift velocity, enables clean separation of neutrons by time-of-flight at pulsed neutron sources. The detector operates at a moderate pressure of a few atmospheres and is able to maintain its good operating characteristics for more than one year on a single gas filling. The compact, high-speed FPGA-based DAQ is simple to setup and operate and is capable of data rates of ~10 MHz. Furthermore, the printed circuit board manufacturing process is inexpensive and allows for freedom in choosing the size and shape of the μPIC (up to 30 × 30 cm 2 , with larger areas accommodated by tiling). These properties make the μPIC an attractive solution for neutron imaging applications in high-rate environments that require very low background, time- resolved measurements and the ability to cover large areas at moderate resolution. References [1] T. Tanimori et al., Nucl. Instr. and Meth. A 529 (2004) 236. [2] J.D. Parker et al., 2009 IEEE Nuclear Science Symposium Conference Record (©2009 IEEE) 1107. [3] J.D. Parker et al., 2010 IEEE Nuclear Science Symposium Conference Record (©2010 IEEE) 291. [4] A. Ochi et al., Nucl. Instr. and Meth. A 471 (2001) 246. [5] R. Orito et al., IEEE Trans. Nucl. Sci., 51 (2004) 1337. [6] H. Kubo et al., 2005 IEEE Nuclear Science Symposium Conference Record (©2005 IEEE) 371. [7] F. Maekawa et al., Nucl. Instr. and Meth. A 600 (2009) 335. [8] R.T. Kouzes, The 3 He Supply Problem, Technical Rpt. PNNL-18388, Pacific Northwest National Laboratory, Richland, WA (2009). 2011 IEEE NSS/MIC/RTSD, Valencia, Spain Neutron Imaging Detector Based on the μPIC Micro-Pixel Gaseous Chamber J.D. Parker , M. Harada 1 , K. Hattori 2 , S. Iwaki, S. Kabuki 3 , Y. Kishimoto 4 , H. Kubo, S. Kurosawa 5 , K. Miuchi, T. Oku 1 , H. Nishimura, T. Sawano, T. Shinohara 1 , J. Suzuki 1 , T. Tanimori, K. Ueno 6 Kyoto University, JAEA 1 , UC Berkeley 2 , Tokai University 3 , KEK 4 , Tohoku University 5 , RIKEN 6 Kyoto University Cosmic Ray Group Pulse-width sum (clocks) 0 100 200 300 400 500 Counts/hr/5 clocks 0 1 2 3 4 5 6 7 8 9 Pulse-width sum (clocks) 0 100 200 300 400 500 Counts/hr/5 clocks 0 1 2 3 4 5 (a) (b) TAT sum after track-length cut 137 Cs No source Require proton and triton peaks in TAT (PID cut) gammas background neutrons Neutron track-length determined from data (~7.6 mm for present data set). TAT sum > 140 to select neutrons. PID cut selects events with double-peak structure associated with proton and triton Bragg peaks. After subtracting the background counts determined from the no-source data, upper limits for the gamma contamination were found to be < 9.3 × 10 -6 and < 3.6 × 10 -6 (95% CL) for the data in plots (a) and (b), respectively. When combined with the gamma detection efficiency (~10 -3 ), this gives an effective gamma sensitivity on the order of 10 -9 or less. Cuts 137 Cs No source None 351363 ± 120 3700.4 ± 8.8 Track length 185.0 ± 2.7 161.1 ± 1.8 + TAT sum 145.6 ± 2.4 148.7 ± 1.8 + PID 43.4 ± 1.3 46.1 ± 1.0 Gamma contamination. Data is in counts/hr. Gas mixture Pressure (atm) Transverse diffusion (μm/cm 1/2 ) Expected position resolution Ar-C 2 H 6 - 3 He (63:7:30) 2 273 (116.3 μm) Ar-C 2 H 6 - 3 He (63:7:30) 3 231 ~100 μm Xe-C 2 H 6 - 3 He (50:20:30) 2 183 ~100 μm Ar-CO 2 - 3 He (50:20:30) 2 107 ~100 μm Gas parameters and expected improvement in resolution. 1. SANS pattern for SiO 2 2. Bragg-edge transmission for Fe powder 1. SANS (J-PARC, Nov. 2009) Sample: spherical SiO 2 nanoparticles (diameter ~200 nm). Detector-to-sample: 1666 mm. Exposure time: 35 min. 2. Bragg-edge transmission (J-PARC, Feb. 2011) Sample: Fe powder (grain size <325 μm, sample thickness of 1.6 cm). Exposure time: 40 min. 3. Resonance absorption (J-PARC, Feb. 2011) Samples: Mn, Mo, Ag, Ta, and In sheets (typical area of 10 × 10 cm2, thicknesses from 0.01 to 1.0 mm). Exposure time: ~16 min/sample. Time (ms) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Transmission 0 0.2 0.4 0.6 0.8 1 Mn Mo Ag Ta In 0 0.04 0.08 0.6 0.8 1 Preliminary Time (ms) 0.5 0.6 0.7 0.8 0.9 1 Transmission 0 0.2 0.4 0.6 0.8 1 Preliminary Indium compared with ENDF/B-VII.0 3. Resonance absorption for various metals Time (ms) 0 2 4 6 8 10 12 14 16 18 Transmission 0.15 0.2 0.25 0.3 0.35 (110) (200) (211) Preliminary Edge spacing consistent with BCC crystal structure ) -1 Å q ( 0 0.004 0.008 0.012 0.016 0.02 -4 10 -3 10 -2 10 Arbitrary units Preliminary Expected distribution for spherical particles 10 cm 400 μm Manufactured by DNP TPC with μPIC 10 × 10 cm 2 μPIC [4] 400-μm pitch with 2D strip readout. 2D readout + drift-time gives 3D track. Low gain variation of ~4% (σ). Stable operation at gains up to 6000 (gain < 1000 needed for neutron imaging). DRIFT CAGE μPIC ALUMINUM VESSEL 9.0 cm 32.8 cm Prototype neutron imaging detector Amplifier-Shaper- Discriminators (ASD) [5] Prototype in experimental area at NOBORU, J-PARC. Cables to FPGA encoder (not pictured) Track width from TAT distribution Peak interpolation (method 1) gives track width as distance between Bragg peaks of proton and triton. End-point extrapolation (method 2) uses the shape of the distribution to extrapolate to zero. Offsets to neutron position were determined with the aid of our GEANT4 simulation and the real data. The final neutron position was determined by the weighted average of methods 1 and 2. Using the image of the Cd test chart (left), the resolution was determined at each slit and averaged to obtain the final value of σ = 116.3 ± 0.5 μm (an improvement of nearly a factor of 3 over the previous determination [3]). Preliminary 5 cm 0.5 mm Preliminary ~3.5 cm μPIC image Courtesy of Ohi, J-PARC Imaging plate Image of Cd test chart Y (strips) 0 10 20 30 40 50 60 Time-above-threshold (clocks) 0 5 10 15 20 25 30 Method 1 Method 2 neutron Threshold 0 1 μPIC ASD Data encoding Two data words per pulse (labeled 0 and 1). Time between words is proportional to energy deposit. Using the shape of the TAT distribution, we can separate the proton and triton (not possible by tracking alone) leading to improved position resolution and strong background rejection. The observed TAT agrees well with the distribution determined from a GEANT4 simulation. Proton-triton track measured with X-ray mode 8 proton triton neutron Relative clock pulse 0 5 10 15 20 25 30 35 40 45 50 Y (strips) 0 10 20 30 40 50 60 Time-above-threshold (clocks) 0 5 10 15 20 25 Distance from interaction point (mm) -4 -2 0 2 4 6 8 Charge (pC) 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 Time-above-threshold (10 ns) 0 5 10 15 20 25 30 Charge TAT TAT distribution (GEANT4) proton triton Email: [email protected]

Transcript of Neutron Imaging Detector Based on the µPIC Micro-Pixel ... · 1. Introduction We have developed a...

Page 1: Neutron Imaging Detector Based on the µPIC Micro-Pixel ... · 1. Introduction We have developed a prototype neutron imaging detector which employs the micro-pixel gaseous chamber

1. IntroductionWe have developed a prototype neutron imaging detector which employs the micro-pixel gaseous chamber (µPIC), a micropattern gaseous detector, coupled with a field programmable gate array (FPGA)-based data acquisition system for applications in small-angle neutron scattering and radiography at high-intensity neutron sources [1-3].

Features of our µPIC-based detector• Gas mixture of Ar-C2H6-3He (63:7:30) at 2 atm (current prototype).

• Large energy release for n+3He reaction (764 keV) requires low gas gain of <1000 (excellent stability against discharge).

• Detection efficiency up to 30% for thermal neutrons.

• Remains operable for more than 1 year on a single gas filling.

• Compact FPGA-based data acquisition system capable of high data rates (~10 MHz).

• Good spatial and time resolutions of <120 µm and ~1 µs, respectively.

• Strong rejection of gamma background (effective gamma sensitivity of <10-9).

• The µPIC is available in sizes up to 30 × 30 cm2 (larger areas accommodated by tiling).

2. Prototype detectorThe prototype detector uses a time projection chamber (TPC) consisting of an aluminum drift plane, drift cage, and a 10 × 10 cm2 µPIC. This TPC is contained within a 1-cm thick aluminum vessel that can accommodate drift heights up to 5 cm and is capable of withstanding pressures up to 2 atm. The µPIC itself was developed in our group at Kyoto University [4] and is manufactured by DaiNippon Printing Co., Ltd., using inexpensive printed circuit board (PCB) technology.

3. FPGA encoder logicThe heart of the data acquisition system (DAQ) is the FPGA encoder module [6]. The version of the FPGA firmware used for neutron imaging is known as X-ray mode 8. In this mode, all incoming data is streamed to the VME memory with no per-event trigger, and the individual events are later isolated in the offline analysis using a clustering algorithm. Additionally, by recording both the leading and trailing edge of the signals (new for mode 8), we are able to estimated the energy deposition using the time-above-threshold (TAT) method with no added cost or complexity for the DAQ.

4. Detector performanceTo study the performance of our prototype detector, three test experiments were carried out at the Japan Spallation Neutron Source (JSNS) located at the Japan Proton Accelerator Research Facility (J-PARC) in Tokai, Japan. The JSNS delivers a 25-Hz pulsed neutron beam to a total of 23 beam ports. Our measurements were carried out at NOBORU (NeutrOn Beamline for Observation and Research) [7], at beamline 10. The experiments were performed in Nov. 2009, June 2010, and Feb. 2011. Results for the first two experiments were reported in Refs. [2,3]. Additional tests were performed at our laboratory using various radioisotope sources. For all of the measurements described below, the detector was filled with a gas mixture of Ar-C2H6-3He (63:7:30) at 2 atm.

4.1. Neutron-gamma separationNeutron-gamma separation is achieved by combining information about the energy deposition (via time-above-threshold) and track length. Neutrons produce proton-triton tracks with essentially the same energy and track lengths, while gamma events deposit much less energy and produce a range of track lengths. The gamma rejection capability of the prototype was studied using a 1-MBq 137Cs source, which produces gamma-rays at an energy of 662 keV.

4.2. Position resolutionTo determine the neutron interaction position for a particular event, we need to know two things: 1) the width of the track in x and y, and 2) the proton direction (both are determined from the shape of the TAT distribution). Once these are known, a correction can be made from the mid-point of the track to the estimated neutron interaction position. The position resolution was studied at NOBORU in Feb. 2011 using a cadmium test chart with a slit pattern consisting of 0.5-mm slits at a pitch of 5 mm. The detector was placed in the neutron beam at distance of 14.5 m from the moderator, and the test chart was attached directly to the front of the vessel.

4.3. Long-term operabilityAt a time when the global demand for 3He is outstripping the world’s supply [8], it is important to minimize the 3He usage of our detector. In our sealed detector, the build-up of impurities over time leads to a degradation in the properties of the gas. Thus, to maintain the desired gas properties, the detector must be periodically evacuated and refilled. Over the course of testing, we found that the detector remained operable for more than one year on a single gas filling. Several strategies can be employed to further increase the time between gas fillings: 1) annealing of the vessel and µPIC to reduce outgassing, and 2) a gas filtration system to remove any impurities that build up in the gas. If these are realized, the operation cycle of the detector could be extended almost indefinitely, greatly reducing maintenance costs related to 3He gas.

5. Demonstration measurementsSeveral demonstration measurements were made at NOBORU in Nov. 2009 (SANS) and Feb. 2011 (resonance absorption, Bragg-edge transmission).

6. Future improvementsCurrently, efforts to optimize the gas mixture for improved position resolution of the detector are underway. For instance, by switching the quencher gas to CO2, we expect diffusion to be greatly reduced, resulting in a position resolution of ~100 µm (estimated using MAGBOLTZ and GEANT4). Further reductions can be obtained by reducing the pixel pitch of the µPIC. By rearranging the anode pixels (dense packing), we can reduce the pixel pitch, and, thereby, improve the position resolution, by as much as another 30%.

For the DAQ, an ultra-compact encoder, which combines new low-power discriminator chips and an FPGA on a single board, has recently been developed in our group. In addition to significantly reducing the bulk of the system, the new encoder is expected to achieve data rates about 5 times higher than the current encoder system.

7. ConclusionBy measuring both the energy deposition (via time-above-threshold) and track positions, a position resolution of <120 µm and an effective gamma sensitivity of <10-9 were achieved. The time resolution of ~1 µs, as determined by the electron drift velocity, enables clean separation of neutrons by time-of-flight at pulsed neutron sources. The detector operates at a moderate pressure of a few atmospheres and is able to maintain its good operating characteristics for more than one year on a single gas filling. The compact, high-speed FPGA-based DAQ is simple to setup and operate and is capable of data rates of ~10 MHz. Furthermore, the printed circuit board manufacturing process is inexpensive and allows for freedom in choosing the size and shape of the µPIC (up to 30 × 30 cm2, with larger areas accommodated by tiling). These properties make the µPIC an attractive solution for neutron imaging applications in high-rate environments that require very low background, time-resolved measurements and the ability to cover large areas at moderate resolution.

References[1] T. Tanimori et al., Nucl. Instr. and Meth. A 529 (2004) 236.[2] J.D. Parker et al., 2009 IEEE Nuclear Science Symposium Conference Record (©2009 IEEE) 1107.[3] J.D. Parker et al., 2010 IEEE Nuclear Science Symposium Conference Record (©2010 IEEE) 291.[4] A. Ochi et al., Nucl. Instr. and Meth. A 471 (2001) 246.[5] R. Orito et al., IEEE Trans. Nucl. Sci., 51 (2004) 1337.[6] H. Kubo et al., 2005 IEEE Nuclear Science Symposium Conference Record (©2005 IEEE) 371.[7] F. Maekawa et al., Nucl. Instr. and Meth. A 600 (2009) 335.[8] R.T. Kouzes, The 3He Supply Problem, Technical Rpt. PNNL-18388, Pacific Northwest National Laboratory, Richland, WA (2009).

2011 IEEE NSS/MIC/RTSD, Valencia, Spain

Neutron Imaging Detector Based on the µPIC Micro-Pixel Gaseous Chamber

J.D. Parker, M. Harada1, K. Hattori2, S. Iwaki, S. Kabuki3, Y. Kishimoto4, H. Kubo, S. Kurosawa5, K. Miuchi, T. Oku1, H. Nishimura, T. Sawano, T. Shinohara1, J. Suzuki1, T. Tanimori, K. Ueno6

Kyoto University, JAEA1, UC Berkeley2, Tokai University3, KEK4, Tohoku University5, RIKEN6

Kyoto UniversityCosmic Ray Group

Pulse-width sum (clocks)0 100 200 300 400 500

Coun

ts/h

r/5 cl

ocks

01

2

3

4

5

6

7

8

9

Pulse-width sum (clocks)0 100 200 300 400 500

Coun

ts/h

r/5 cl

ocks

0

1

2

3

4

5

(a)

(b)

TAT sum after track-length cut137CsNo source

Require proton and triton peaks in TAT (PID cut)

gammas

background neutrons

• Neutron track-length determined from data (~7.6 mm for present data set).

• TAT sum > 140 to select neutrons.

• PID cut selects events with double-peak structure associated with proton and triton Bragg peaks.

After subtracting the background counts determined from the no-source data, upper limits for the gamma contamination were found to be < 9.3 × 10-6 and < 3.6 × 10-6 (95% CL) for the data in plots (a) and (b), respectively. When combined with the gamma detection efficiency (~10-3), this gives an effective gamma sensitivity on the order of 10-9 or less.

Cuts 137Cs No sourceNone 351363 ± 120 3700.4 ± 8.8

Track length 185.0 ± 2.7 161.1 ± 1.8

+ TAT sum 145.6 ± 2.4 148.7 ± 1.8

+ PID 43.4 ± 1.3 46.1 ± 1.0

Gamma contamination. Data is in counts/hr.

Gas mixture Pressure(atm)

Transverse diffusion

(µm/cm1/2)

Expected position

resolution

Ar-C2H6-3He (63:7:30) 2 273 (116.3 µm)

Ar-C2H6-3He (63:7:30) 3 231 ~100 µm

Xe-C2H6-3He (50:20:30) 2 183 ~100 µm

Ar-CO2-3He (50:20:30) 2 107 ~100 µm

Gas parameters and expected improvement in resolution.

1. SANS pattern for SiO2

2. Bragg-edge transmission for Fe powder

1. SANS (J-PARC, Nov. 2009)Sample: spherical SiO2 nanoparticles (diameter ~200 nm).

Detector-to-sample: 1666 mm.

Exposure time: 35 min.

2. Bragg-edge transmission (J-PARC, Feb. 2011)Sample: Fe powder (grain size <325 µm, sample thickness of 1.6 cm).Exposure time: 40 min.

3. Resonance absorption (J-PARC, Feb. 2011)Samples: Mn, Mo, Ag, Ta, and In sheets (typical area of 10 × 10 cm2, thicknesses from 0.01 to 1.0 mm).Exposure time: ~16 min/sample.

Time (ms)0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Tran

smiss

ion

0

0.2

0.4

0.6

0.8

1 MnMoAgTaIn

0 0.04 0.080.6

0.8

1

Preliminary

Time (ms)0.5 0.6 0.7 0.8 0.9 1

Trans

miss

ion

0

0.2

0.4

0.6

0.8

1

Preliminary

Indium compared with ENDF/B-VII.0

3. Resonance absorption for various metals

Time (ms)0 2 4 6 8 10 12 14 16 18

Tran

smiss

ion

0.15

0.2

0.25

0.3

0.35(110)

(200)(211)

Preliminary

Edge spacing consistent with BCC crystal structure

)-1Åq (0 0.004 0.008 0.012 0.016 0.02

-410

-310

-210

Arbi

trary

uni

ts

Preliminary

Expected distribution for spherical particles

10 cm

400 µm

Manufactured by DNP

TPC with µPIC

10 × 10 cm2 µPIC [4]

• 400-µm pitch with 2D strip readout.

• 2D readout + drift-time gives 3D track.

• Low gain variation of ~4% (σ).• Stable operation at gains up to

6000 (gain < 1000 needed for neutron imaging).

DRIFT CAGE

µPIC

ALUMINUM VESSEL

9.0

cm

32.8 cm

Prototype neutron imaging detectorAmplifier-Shaper-

Discriminators (ASD) [5]

Prototype in experimental area at NOBORU, J-PARC.

Cables to FPGA encoder (not pictured)

Track width from TAT distribution• Peak interpolation (method 1) gives track width as distance between

Bragg peaks of proton and triton.• End-point extrapolation (method 2) uses the shape of the distribution

to extrapolate to zero.• Offsets to neutron position were determined with the aid of our

GEANT4 simulation and the real data.

The final neutron position was determined by the weighted average of methods 1 and 2. Using the image of the Cd test chart (left), the resolution was determined at each slit and averaged to obtain the final value of σ = 116.3 ± 0.5 µm (an improvement of nearly a

factor of 3 over the previous determination [3]).

Preliminary

5 cm

0.5 mm

Preliminary

~3.5 cm

µPIC image

Courtesy of Ohi, J-PARC

Imaging plateImage of Cd test chart

Y (strips)0 10 20 30 40 50 60Ti

me-

abov

e-th

resh

old

(clo

cks)

0

5

10

15

20

25

30Method 1

Method 2neutron

Threshold

0 1

µPIC

ASD

Data encoding

• Two data words per pulse (labeled 0 and 1).

• Time between words is proportional to energy deposit.

Using the shape of the TAT distribution, we can separate the proton and triton (not possible by tracking alone) leading to improved position resolution and strong background rejection.

The observed TAT agrees well w i t h t h e d i s t r i b u t i o n d e t e r m i n e d from a GEANT4 simulation.

Proton-triton track measured with X-ray mode 8

protontriton

neutron

Relat

ive cl

ock p

ulse

05

101520253035404550

Y (strips)0 10 20 30 40 50 60Ti

me-

abov

e-th

resh

old

(clo

cks)

0

5

10

15

20

25

Distance from interaction point (mm)-4 -2 0 2 4 6 8

Char

ge (p

C)

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

0.18

Tim

e-ab

ove-

thre

shol

d (1

0 ns)

0

5

10

15

20

25

30ChargeTAT

TAT distribution (GEANT4)

protontriton

Email: [email protected]