MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building...
Transcript of MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building...
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
C OVE
R
G-000
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
MURRAY-CALLOWAY EDCINDUSTRIAL DEVELOPMENT
PROJECT NUMBER: 15013PHASE: SCHEMATIC DESIGN - NOT FOR CONSTRUCTION
DATE: 09.11.2015
MURRAY WEST INDUSTRIAL PARK, MURRAY, KY 42071
SHEET INDEX
SHEETNUMBER SHEET NAME ISSUE DATE
DesignerA-103 SECOND FLOOR PLAN 09/15/15A-104 OFFICE PLANS 09/21/15
GENERALG-000 COVER 11/19/13G-001 GENERAL REQUIREMENTS 11/19/13
ARCHITECTURALA-001 PARTITION TYPES 11/19/13A-101 ARCHITECTURAL SITE PLAN 11/19/13A-102 FIRST FLOOR PLAN 11/19/13A-105 REFLECTED CEILING PLAN 12/15/14A-106 ROOF PLAN 12/15/14A-201 EXTERIOR ELEVATIONS 11/19/13A-301 BUILDING SECTIONS 12/15/14A-302 WALL SECTIONS 12/15/14A-401 LARGE SCALE PLANS / INTERIOR ELEVATIONS 12/15/14A-501 DETAILS 12/15/14A-601 DOOR SCHEDULE 11/19/13
1067 KEENLAND DR, MURRAY, KY 42071T: 270.761.5674
PROJECT ARCHITECT: JOSH VERNON, AIAEMAIL: [email protected]
1215 DIUGUID DR, MURRAY, KY 42071T: 270.753.7307
STRUCTURAL ENGINEER: RON BACON, P.E.EMAIL: [email protected]
CIVIL ENGINEER: BOBBY DEITZ, P.E.EMAIL: [email protected]
PROJECT LOCATION
PROJECT LOCATION
500 SOUTH 17TH STREET, PADUCAH, KY 42002T: 270.444.9274
MECHANICAL ENGINEER: BACCUS OLIVER, P.E.EMAIL: [email protected]
ELECTRICAL ENGINEER: DAVID URY, P.E.EMAIL: [email protected]
21 3 4 5 6 7
A
B
C
D
E
F
300' - 0"
250'
- 0"
50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0"
50' -
0"
50' -
0"
50' -
0"
50' -
0"
50' -
0"
6.5
E.5
E.6
1A-104
ALTERNATE 1
MANUFACTURING101
18' - 0" 8' - 0" 8' - 0" 9' - 0" 33' - 0"33' - 0" 9' - 0" 8' - 0"
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
FIR S
T F L
OOR
PLA N
A-102
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
GENERAL NOTES
KEYNOTES
1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.
2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.
3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.
SCALE: 1/16" = 1'-0"1 LEVEL 1
21 3 4 5 6 7
A
B
C
D
E
F
6.5
E.5
E.6
2A-104
ALTERNATE 1
300' - 0"
250'
- 0"
50' -
0"
50' -
0"
50' -
0"
50' -
0"
50' -
0"
24' -
0"
18' -
0"
31' -
0"
54' -
6"
12' -
6"
7' -
6"32
' - 6
"20
' - 0
"
50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0"
24' -
0"
18' -
0"
45' -
6"
29' -
0"
7' -
6"9'
- 0"
42' -
0"
25' -
0"
6' -
0"
7' - 6" 12' - 6" 62' - 0" 40' - 0" 5' - 6" 74' - 6" 18' - 0" 20' - 0" 13' - 0" 27' - 0" 20' - 0"
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
SEC O
ND F
LOO R
PL A
N
A-103
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
GENERAL NOTES
KEYNOTES
1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.
2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.
3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.
SCALE: 1/16" = 1'-0"1 LEVEL 2
5 6 7
F
6.5
E.5
E.6
VESTIBULE102
CUSTODIAL103
FILE / COPY104
RECEPTION105
FUTURERESTRM
106
FUTURERESTRM
107
OFFICE112
OPEN OFFICE108
MECH.109
OFFICE111RESTRM
110
CONFERENCE113
FUTURE OFFICE114FUTURE OFFICE
115STORAGE116
26' - 6"
16' - 2"
10' - 4"
16' - 8"
9' - 4"
5 6 7
F
6.5
E.5
E.6
UNFINISHEDLEVEL
203
RESTRM204
RESTRM205
FUTURE OFFICE206
FUTURECONFERENCE
207
ELEC / DATA202
STAIR201
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
OFFI
C E P
L ANS
A-104
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
GENERAL NOTES
KEYNOTES
1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.
2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.
3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.
SCALE: 1/8" = 1'-0"1 OFFICE - LEVEL 1
SCALE: 1/8" = 1'-0"2 OFFICE - LEVEL 2
21 3 4 5 6 7
A
B
C
D
E
F
1/8" / 1'-0" 1/8" / 1'-0"
1/4" / 1'-0"
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
ROO F
PL A
N
A-106
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
GENERAL NOTES
KEYNOTES
KEYNOTE1
1. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.
2. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.
SCALE: 1/16" = 1'-0"1 ROOF PLAN
LEVEL 1100' - 0"
LEVEL 2117' - 6"
T.O. PARAPET138' - 0"
21 3 4 5 6 76.5E.6
LEVEL 1100' - 0"
LEVEL 2117' - 6"
T.O. PARAPET138' - 0"
ABCDEF E.5
10' -
6"
10' -
6"
17' -
0"
LEVEL 1100' - 0"
LEVEL 2117' - 6"
T.O. PARAPET138' - 0"
2 134567 6.5 E.6
LEVEL 1100' - 0"
LEVEL 2117' - 6"
T.O. PARAPET138' - 0"
B C D E FE.5
COPYRIGHT © 2015 URBAN FABRIC, PLLC
SHEET INFORMATION
ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:
PROJECT INFO. SHEET TITLE
ISSU
EDA
TEDE
SCRI
PTIO
N
MUR
RAY
WES
T IN
DUST
RIAL
PA R
K, M
U RRA
Y, K
Y 42
071
11.02.201515013
JVJV
EXTE
RIOR
ELE
VATI
O NS
A-201
MU R
RAY-
C ALL
OWA Y
ED C
IND U
STRI
AL D
EVEL
O PM
E NT
GENERAL NOTES
KEYNOTES
1. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.
2. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.
3. REFER TO BUILDING SECTIONS, WALL SECTIONS, AND DETAILS FOR INFORMATION NOT SHOWNIN THE ELEVATION DRAWINGS.
4. ALL HEIGHTS ARE REFERENCED TO STRUCTURE. ACTUAL FINISHED FLOOR AND ROUGHOPENING DIMENSIONS VARY DEPENDING ON MATERIAL, U.N.O.
SCALE: 1/16" = 1'-0"1 EAST ELEVATION
SCALE: 1/16" = 1'-0"2 NORTH ELEVATION
SCALE: 1/16" = 1'-0"3 WEST ELEVATION
SCALE: 1/16" = 1'-0"4 SOUTH ELEVATION