MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building...

6
COPYRIGHT © 2015 URBAN FABRIC, PLLC SHEET INFORMATION ISSUE DATE: PROJECT NUMBER: DRAWN BY: APPROVED BY: PROJECT INFO. SHEET TITLE ISSUE DATE DESCRIPTION MURRAY WEST INDUSTRIAL PARK, MURRAY, KY 42071 11.02.2015 15013 JV JV COVER G-000 MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT PROJECT NUMBER: 15013 PHASE: SCHEMATIC DESIGN - NOT FOR CONSTRUCTION DATE: 09.11.2015 MURRAY WEST INDUSTRIAL PARK, MURRAY, KY 42071 SHEET INDEX SHEET NUMBER SHEET NAME ISSUE DATE Designer A-103 SECOND FLOOR PLAN 09/15/15 A-104 OFFICE PLANS 09/21/15 GENERAL G-000 COVER 11/19/13 G-001 GENERAL REQUIREMENTS 11/19/13 ARCHITECTURAL A-001 PARTITION TYPES 11/19/13 A-101 ARCHITECTURAL SITE PLAN 11/19/13 A-102 FIRST FLOOR PLAN 11/19/13 A-105 REFLECTED CEILING PLAN 12/15/14 A-106 ROOF PLAN 12/15/14 A-201 EXTERIOR ELEVATIONS 11/19/13 A-301 BUILDING SECTIONS 12/15/14 A-302 WALL SECTIONS 12/15/14 A-401 LARGE SCALE PLANS / INTERIOR ELEVATIONS 12/15/14 A-501 DETAILS 12/15/14 A-601 DOOR SCHEDULE 11/19/13 1067 KEENLAND DR, MURRAY, KY 42071 T: 270.761.5674 PROJECT ARCHITECT: JOSH VERNON, AIA EMAIL: [email protected] 1215 DIUGUID DR, MURRAY, KY 42071 T: 270.753.7307 STRUCTURAL ENGINEER: RON BACON, P.E. EMAIL: [email protected] CIVIL ENGINEER: BOBBY DEITZ, P.E. EMAIL: [email protected] PROJECT LOCATION PROJECT LOCATION 500 SOUTH 17TH STREET, PADUCAH, KY 42002 T: 270.444.9274 MECHANICAL ENGINEER: BACCUS OLIVER, P.E. EMAIL: [email protected] ELECTRICAL ENGINEER: DAVID URY, P.E. EMAIL: [email protected]

Transcript of MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building...

Page 1: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

C OVE

R

G-000

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

MURRAY-CALLOWAY EDCINDUSTRIAL DEVELOPMENT

PROJECT NUMBER: 15013PHASE: SCHEMATIC DESIGN - NOT FOR CONSTRUCTION

DATE: 09.11.2015

MURRAY WEST INDUSTRIAL PARK, MURRAY, KY 42071

SHEET INDEX

SHEETNUMBER SHEET NAME ISSUE DATE

DesignerA-103 SECOND FLOOR PLAN 09/15/15A-104 OFFICE PLANS 09/21/15

GENERALG-000 COVER 11/19/13G-001 GENERAL REQUIREMENTS 11/19/13

ARCHITECTURALA-001 PARTITION TYPES 11/19/13A-101 ARCHITECTURAL SITE PLAN 11/19/13A-102 FIRST FLOOR PLAN 11/19/13A-105 REFLECTED CEILING PLAN 12/15/14A-106 ROOF PLAN 12/15/14A-201 EXTERIOR ELEVATIONS 11/19/13A-301 BUILDING SECTIONS 12/15/14A-302 WALL SECTIONS 12/15/14A-401 LARGE SCALE PLANS / INTERIOR ELEVATIONS 12/15/14A-501 DETAILS 12/15/14A-601 DOOR SCHEDULE 11/19/13

1067 KEENLAND DR, MURRAY, KY 42071T: 270.761.5674

PROJECT ARCHITECT: JOSH VERNON, AIAEMAIL: [email protected]

1215 DIUGUID DR, MURRAY, KY 42071T: 270.753.7307

STRUCTURAL ENGINEER: RON BACON, P.E.EMAIL: [email protected]

CIVIL ENGINEER: BOBBY DEITZ, P.E.EMAIL: [email protected]

PROJECT LOCATION

PROJECT LOCATION

500 SOUTH 17TH STREET, PADUCAH, KY 42002T: 270.444.9274

MECHANICAL ENGINEER: BACCUS OLIVER, P.E.EMAIL: [email protected]

ELECTRICAL ENGINEER: DAVID URY, P.E.EMAIL: [email protected]

Page 2: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

21 3 4 5 6 7

A

B

C

D

E

F

300' - 0"

250'

- 0"

50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0"

50' -

0"

50' -

0"

50' -

0"

50' -

0"

50' -

0"

6.5

E.5

E.6

1A-104

ALTERNATE 1

MANUFACTURING101

18' - 0" 8' - 0" 8' - 0" 9' - 0" 33' - 0"33' - 0" 9' - 0" 8' - 0"

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

FIR S

T F L

OOR

PLA N

A-102

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

GENERAL NOTES

KEYNOTES

1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.

2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.

3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.

SCALE: 1/16" = 1'-0"1 LEVEL 1

Page 3: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

21 3 4 5 6 7

A

B

C

D

E

F

6.5

E.5

E.6

2A-104

ALTERNATE 1

300' - 0"

250'

- 0"

50' -

0"

50' -

0"

50' -

0"

50' -

0"

50' -

0"

24' -

0"

18' -

0"

31' -

0"

54' -

6"

12' -

6"

7' -

6"32

' - 6

"20

' - 0

"

50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0" 50' - 0"

24' -

0"

18' -

0"

45' -

6"

29' -

0"

7' -

6"9'

- 0"

42' -

0"

25' -

0"

6' -

0"

7' - 6" 12' - 6" 62' - 0" 40' - 0" 5' - 6" 74' - 6" 18' - 0" 20' - 0" 13' - 0" 27' - 0" 20' - 0"

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

SEC O

ND F

LOO R

PL A

N

A-103

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

GENERAL NOTES

KEYNOTES

1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.

2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.

3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.

SCALE: 1/16" = 1'-0"1 LEVEL 2

Page 4: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

5 6 7

F

6.5

E.5

E.6

VESTIBULE102

CUSTODIAL103

FILE / COPY104

RECEPTION105

FUTURERESTRM

106

FUTURERESTRM

107

OFFICE112

OPEN OFFICE108

MECH.109

OFFICE111RESTRM

110

CONFERENCE113

FUTURE OFFICE114FUTURE OFFICE

115STORAGE116

26' - 6"

16' - 2"

10' - 4"

16' - 8"

9' - 4"

5 6 7

F

6.5

E.5

E.6

UNFINISHEDLEVEL

203

RESTRM204

RESTRM205

FUTURE OFFICE206

FUTURECONFERENCE

207

ELEC / DATA202

STAIR201

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

OFFI

C E P

L ANS

A-104

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

GENERAL NOTES

KEYNOTES

1. ALL DIMENSIONS REFERENCED TO AN EXISTING ELEMENT ARE APPROXIMATE. NEW WALLSAND/OR ELEMENTS THAT APPEAR TO BE FLUSH WITH EXISTING WALLS AND/OR ELEMENTSSHALL BE CONSTRUCTED AS SHOWN.

2. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.

3. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.

SCALE: 1/8" = 1'-0"1 OFFICE - LEVEL 1

SCALE: 1/8" = 1'-0"2 OFFICE - LEVEL 2

Page 5: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

21 3 4 5 6 7

A

B

C

D

E

F

1/8" / 1'-0" 1/8" / 1'-0"

1/4" / 1'-0"

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

ROO F

PL A

N

A-106

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

GENERAL NOTES

KEYNOTES

KEYNOTE1

1. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.

2. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.

SCALE: 1/16" = 1'-0"1 ROOF PLAN

Page 6: MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT · a-201 exterior elevations 11/19/13 a-301 building sections 12/15/14 a-302 wall sections 12/15/14 a-401 large scale plans / interior elevations

LEVEL 1100' - 0"

LEVEL 2117' - 6"

T.O. PARAPET138' - 0"

21 3 4 5 6 76.5E.6

LEVEL 1100' - 0"

LEVEL 2117' - 6"

T.O. PARAPET138' - 0"

ABCDEF E.5

10' -

6"

10' -

6"

17' -

0"

LEVEL 1100' - 0"

LEVEL 2117' - 6"

T.O. PARAPET138' - 0"

2 134567 6.5 E.6

LEVEL 1100' - 0"

LEVEL 2117' - 6"

T.O. PARAPET138' - 0"

B C D E FE.5

COPYRIGHT © 2015 URBAN FABRIC, PLLC

SHEET INFORMATION

ISSUE DATE:PROJECT NUMBER:DRAWN BY:APPROVED BY:

PROJECT INFO. SHEET TITLE

ISSU

EDA

TEDE

SCRI

PTIO

N

MUR

RAY

WES

T IN

DUST

RIAL

PA R

K, M

U RRA

Y, K

Y 42

071

11.02.201515013

JVJV

EXTE

RIOR

ELE

VATI

O NS

A-201

MU R

RAY-

C ALL

OWA Y

ED C

IND U

STRI

AL D

EVEL

O PM

E NT

GENERAL NOTES

KEYNOTES

1. ALL EQUIPMENT AND SYSTEMS ARE TO BE INSTALLED AS RECOMMENDED BY THEMANUFACTURER FOR A COMPLETE AND FUNCTIONAL ASSEMBLY, INCLUDING ALL NECESSARYCOMPONENTS FOR THE SPECIFIED WARRANTY.

2. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT THEARCHITECT FOR CLARIFICATION. IF NO CLARIFICATION IS AVAILABLE, THE MORE RESTRICTIVEOPTION IS TO BE FOLLOWED.

3. REFER TO BUILDING SECTIONS, WALL SECTIONS, AND DETAILS FOR INFORMATION NOT SHOWNIN THE ELEVATION DRAWINGS.

4. ALL HEIGHTS ARE REFERENCED TO STRUCTURE. ACTUAL FINISHED FLOOR AND ROUGHOPENING DIMENSIONS VARY DEPENDING ON MATERIAL, U.N.O.

SCALE: 1/16" = 1'-0"1 EAST ELEVATION

SCALE: 1/16" = 1'-0"2 NORTH ELEVATION

SCALE: 1/16" = 1'-0"3 WEST ELEVATION

SCALE: 1/16" = 1'-0"4 SOUTH ELEVATION