1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior...

6
PET SUPPLIES PLUS 1300 MACDADE BLVD. WOODLYN, PA ___________ C1.0 COVER SHEET C2.0 SCOPE OF WORK MATRIX C3.0 APPROVED VENDORS SCHEDULE C4.0 GENERAL INFORMATION C5.0 COMCHECK FORMS AS1.0 ARCHITECTURAL SPECIFICATIONS AS1.1 ARCHITECTURAL SPECIFICATIONS AS1.2 ARCHITECTURAL SPECIFICATIONS AS1.3 ARCHITECTURAL SPECIFICATIONS AS1.4 ARCHITECTURAL SPECIFICATIONS AS1.5 ARCHITECTURAL SPECIFICATIONS AS1.6 ARCHITECTURAL SPECIFICATIONS AS1.7 ARCHITECTURAL SPECIFICATIONS AS1.8 ARCHITECTURAL SPECIFICATIONS D1.0 DEMOLITION PLAN A1.0 FLOOR PLAN A2.0 FIXTURE PLAN AND FLOOR FINISHES PLAN A3.0 REFLECTED CEILING PLAN A4.0 ENLARGED PLANS A5.0 EXTERIOR ELEVATIONS A6.0 INTERIOR ELEVATIONS A6.1 INTERIOR ELEVATIONS A6.2 INTERIOR ELEVATIONS A7.0 WALL SECTIONS A8.0 DETAILS A8.1 DETAILS A8.2 DETAILS A9.0 DOOR SCHEDULE AND DETAILS A9.1 FINISH SCHEDULE MPS1.0 MECHANICAL AND PLUMBING SPECIFICATIONS M1.0 MECHANICAL PLAN M2.0 MECHANICAL SCHEDULE AND DETAILS P1.0 PLUMBING SUPPLY PLAN P1.1 PLUMBING WASTE PLAN P1.2 GAS PLAN & DETAILS P2.0 PLUMBING SCHEDULES AND DETAILS P2.1 PLUMBING DETAILS ES1.0 ELECTRICAL SPECIFICATIONS E1.0 POWER SYSTEMS PLAN E2.0 LIGHTING PLAN E3.0 ELECTRICAL SCHEDULES AND DETAILS E4.0 ELECTRICAL SCHEDULES, GENERAL NOTES AND DETAILS INDEX OF DRAWINGS - THE FOLLOWING PORTIONS OF THE DESIGN SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND APPROVED PRIOR TO INSTALLATION. SEPARATE PERMITS MAY BE REQUIRED -SIGNAGE -FIRE SPRINKLER MODIFICATION - ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT WITHIN 30 DAYS AFTER THE ISSUANCE OF PERMIT. - ARCHITECT OF RECORD SHALL BE RESPONSIBLE FOR COORDINATING ALL SUBMITTAL DOCUMENTS PREPARED BY OTHERS. ALL DEFERRED SUBMITTALS SHALL BE COORDINATED BY CONTRACTOR AT TIME OF PERMIT. 1300 MACDADE BLVD. WOODLYN, PA CONTACTS CODES BUILDING CODE : 2009 INTERNATIONAL BUILDING CODE PLUMBING CODE : 2009 INTERNATIONAL PLUMBING CODE MECHANICAL CODE : 2009 INTERNATIONAL MECHANICAL CODE ELECTRICAL CODE : 2008 NEC-NFPA 70 FIRE CODE : 2009 INTERNATIONAL FIRE CODE ENERGY CODE : 2009 NECC ACCESSIBILITY CODE : 2015 INTERNATIONAL BUILDING CODE BUILDING INFORMATION: BUILDING: EXISTING USE GROUP: M, MERCANTILE CONSTRUCTION TYPE: II-B BUILDING IS FULLY SPRINKLED EXISTING SPRINKLER SYSTEM TO BE MODIFIED FOR NEW LAYOUT GROSS LEASED AREA: 10,085 S.F.* SALES AREA, LAVS: 9,414 S.F. @ 1 OCC/30 S.F. = 314 OCC. GROOMING SERVICES: 116 S.F. @ 1 OCC/100 S.F. = 2 OCC. STOCKROOM: 555 S.F. @ 1 OCC/300 S.F. = 2 OCC. TOTAL OCCUPANT LOAD 318 OCC. TRAVEL DISTANCE PERMITTED: 250'-0" MAXIMUM PROVIDED: 157'-0" ACTUAL PLUMBING FIXTURE COUNT WATER CLOSETS: 1/500 = 1 REQUIRED; 1 PROVIDED MEN 1 REQUIRED; 1 PROVIDED WOMEN LAVATORIES: 1/750 = 1 REQUIRED; 1 PROVIDED MEN 1 REQUIRED; 1 PROVIDED WOMEN DRINKING FOUNTAIN: 1/1000 = 1 REQUIRED; 2 PROVIDED (HI-LO UNIT) SERVICE SINK: 1 REQUIRED; 1 PROVIDED. EXIT WIDTH REQUIRED: 0.2 INCHES 318 OCCUPANT LOAD: 63.6 INCHES PROVIDED: 104 INCHES MAIN ENTRY DOOR = 68 INCHES EGRESS DOOR = 72 INCHES (2 DOOR AT 36 INCHES) NUMBER OF EXITS REQUIRED REQUIRED: 2 PROVIDED: 3 * LEASEABLE AREA IS TO BE MEASURED PER BOMA STANDARDS (EXTERIOR FACE OF EXTERIOR WALLS AND CENTERLINE OF SHARED WALLS). PROJECT SITE DEFERRED SUBMITTALS LOCATION MAP VICINITY MAP TENANT: PET SUPPLIES PLUS 17197 N. LAUREL PARK DRIVE SUITE 402 LIVONIA, MI 48152 ARCHITECT: JOE HOCHENDONER PHONE: 734.793.6671 FAX: 734.793.6700 BUILDING DEPARTMENT: 100 MACDADE BOULEVARD FOLSOM, PA 19033 ROBERT GRIFFITH PHONE: 601-534-4800 FAX: LANDLORD: RAYMOUR & FLANIGAN REAL ESTATE 7248 MORGAN RD. PO BOX 220 LIVERPOOL, NY 13088 CONTACT: TREVOR C. EDKIN OFFICE: 315-461-3658 CELL: 315-225-8061 EMAIL: [email protected] DESIGNER: DESIGN FORUM ARCHITECTS 700 PETE ROSE WAY SUITE 460 CINCINNATI, OHIO 45203 CONTACT:GLEN MIDDLETON PHONE: 513-421-2210 FAX: 513-421-2386 PROJECT CONSISTS OF A RENOVATION TO AN EXISTING STORE FOR A NEW PET SUPPLIES RETAIL STORE INCLUDING PET GROOMING SERVICES. WORK INCLUDES: INTERIOR WALLS, CEILING, FINISHES INTERIOR DOORS GLASS AND ALUMINUM VESTIBULE PLUMBING HVAC ELECTRICAL POWER AND LIGHTING RETAIL DISPLAY FIXTURES AND RACKING SCOPE OF WORK LANDLORD REQUIRED CONTRACTORS: CONSTRUCTION CONTACT: SHAUN MACLELLAN PHONE: 440.829.9139 REVISIONS SHEETS DESCRIPTION REVISION DATE PROJECT SITE ROOFING CONTRACTOR: FIRE SUPPRESSION CONTRACTOR: FIRE ALARM CONTRACTOR:

Transcript of 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior...

Page 1: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule

PE

T S

UP

PLI

ES

PLU

S13

00 M

AC

DA

DE

BLV

D.

WO

OD

LYN

, PA

____

____

___

C1.0 COVER SHEETC2.0 SCOPE OF WORK MATRIXC3.0 APPROVED VENDORS SCHEDULEC4.0 GENERAL INFORMATIONC5.0 COMCHECK FORMS

AS1.0 ARCHITECTURAL SPECIFICATIONSAS1.1 ARCHITECTURAL SPECIFICATIONSAS1.2 ARCHITECTURAL SPECIFICATIONSAS1.3 ARCHITECTURAL SPECIFICATIONSAS1.4 ARCHITECTURAL SPECIFICATIONSAS1.5 ARCHITECTURAL SPECIFICATIONSAS1.6 ARCHITECTURAL SPECIFICATIONSAS1.7 ARCHITECTURAL SPECIFICATIONSAS1.8 ARCHITECTURAL SPECIFICATIONS

D1.0 DEMOLITION PLAN

A1.0 FLOOR PLANA2.0 FIXTURE PLAN AND FLOOR FINISHES PLANA3.0 REFLECTED CEILING PLANA4.0 ENLARGED PLANSA5.0 EXTERIOR ELEVATIONSA6.0 INTERIOR ELEVATIONSA6.1 INTERIOR ELEVATIONSA6.2 INTERIOR ELEVATIONSA7.0 WALL SECTIONSA8.0 DETAILSA8.1 DETAILSA8.2 DETAILSA9.0 DOOR SCHEDULE AND DETAILSA9.1 FINISH SCHEDULE

MPS1.0 MECHANICAL AND PLUMBING SPECIFICATIONSM1.0 MECHANICAL PLANM2.0 MECHANICAL SCHEDULE AND DETAILSP1.0 PLUMBING SUPPLY PLANP1.1 PLUMBING WASTE PLANP1.2 GAS PLAN & DETAILSP2.0 PLUMBING SCHEDULES AND DETAILSP2.1 PLUMBING DETAILS

ES1.0 ELECTRICAL SPECIFICATIONSE1.0 POWER SYSTEMS PLANE2.0 LIGHTING PLANE3.0 ELECTRICAL SCHEDULES AND DETAILSE4.0 ELECTRICAL SCHEDULES, GENERAL NOTES AND DETAILS

INDEX OF DRAWINGS

- THE FOLLOWING PORTIONS OF THE DESIGN SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND APPROVED PRIOR TO INSTALLATION. SEPARATEPERMITS MAY BE REQUIRED

-SIGNAGE-FIRE SPRINKLER MODIFICATION

- ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE BUILDINGDEPARTMENT WITHIN 30 DAYS AFTER THE

ISSUANCE OF PERMIT.- ARCHITECT OF RECORD SHALL BE RESPONSIBLE FOR COORDINATING ALL

SUBMITTAL DOCUMENTS PREPARED BY OTHERS. ALL DEFERRED SUBMITTALSSHALL BE COORDINATED BY CONTRACTOR AT TIME OF PERMIT.

1300 MACDADE BLVD.WOODLYN, PA

CONTACTS

CODES

BUILDING CODE : 2009 INTERNATIONAL BUILDING CODEPLUMBING CODE : 2009 INTERNATIONAL PLUMBING CODEMECHANICAL CODE : 2009 INTERNATIONAL MECHANICAL CODEELECTRICAL CODE : 2008 NEC-NFPA 70FIRE CODE : 2009 INTERNATIONAL FIRE CODEENERGY CODE : 2009 NECCACCESSIBILITY CODE : 2015 INTERNATIONAL BUILDING CODE

BUILDING INFORMATION:BUILDING: EXISTINGUSE GROUP: M, MERCANTILECONSTRUCTION TYPE: II-B

BUILDING IS FULLY SPRINKLEDEXISTING SPRINKLER SYSTEM TO BE MODIFIED FOR NEW LAYOUT

GROSS LEASED AREA: 10,085 S.F.*SALES AREA, LAVS: 9,414 S.F. @ 1 OCC/30 S.F. = 314 OCC.GROOMING SERVICES: 116 S.F. @ 1 OCC/100 S.F. = 2 OCC.STOCKROOM: 555 S.F. @ 1 OCC/300 S.F. = 2 OCC.TOTAL OCCUPANT LOAD 318 OCC.

TRAVEL DISTANCEPERMITTED: 250'-0" MAXIMUMPROVIDED: 157'-0" ACTUAL

PLUMBING FIXTURE COUNTWATER CLOSETS: 1/500 = 1 REQUIRED; 1 PROVIDED MEN

1 REQUIRED; 1 PROVIDED WOMENLAVATORIES: 1/750 = 1 REQUIRED; 1 PROVIDED MEN

1 REQUIRED; 1 PROVIDED WOMENDRINKING FOUNTAIN: 1/1000 = 1 REQUIRED; 2 PROVIDED (HI-LO UNIT)SERVICE SINK: 1 REQUIRED; 1 PROVIDED.

EXIT WIDTH REQUIRED:

0.2 INCHES 318 OCCUPANT LOAD: 63.6 INCHESPROVIDED: 104 INCHESMAIN ENTRY DOOR = 68 INCHESEGRESS DOOR = 72 INCHES (2 DOOR AT 36 INCHES)

NUMBER OF EXITS REQUIREDREQUIRED: 2PROVIDED: 3

* LEASEABLE AREA IS TO BE MEASURED PER BOMA STANDARDS (EXTERIOR FACEOF EXTERIOR WALLS AND CENTERLINE OF SHARED WALLS).

PROJECT SITE

DEFERRED SUBMITTALS

LOCATION MAP

VICINITY MAP

TENANT:

PET SUPPLIES PLUS17197 N. LAUREL PARK DRIVESUITE 402LIVONIA, MI 48152

ARCHITECT: JOE HOCHENDONERPHONE: 734.793.6671FAX: 734.793.6700

BUILDING DEPARTMENT:

100 MACDADE BOULEVARDFOLSOM,PA 19033

ROBERT GRIFFITHPHONE: 601-534-4800FAX:

LANDLORD:

RAYMOUR & FLANIGAN REAL ESTATE7248 MORGAN RD.PO BOX 220LIVERPOOL, NY 13088CONTACT: TREVOR C. EDKINOFFICE: 315-461-3658CELL: 315-225-8061EMAIL: [email protected]

DESIGNER:

DESIGN FORUM ARCHITECTS700 PETE ROSE WAY SUITE 460CINCINNATI, OHIO 45203

CONTACT:GLEN MIDDLETONPHONE: 513-421-2210FAX: 513-421-2386

PROJECT CONSISTS OF A RENOVATION TO AN EXISTING STORE FOR A NEW PETSUPPLIES RETAIL STORE INCLUDING PET GROOMING SERVICES.

WORK INCLUDES:INTERIOR WALLS, CEILING, FINISHESINTERIOR DOORSGLASS AND ALUMINUM VESTIBULEPLUMBINGHVACELECTRICAL POWER AND LIGHTINGRETAIL DISPLAY FIXTURES AND RACKING

SCOPE OF WORK

LANDLORD REQUIRED CONTRACTORS:

CONSTRUCTION CONTACT:SHAUN MACLELLANPHONE: 440.829.9139

REVISIONSSHEETSDESCRIPTIONREVISION DATE

PROJECT SITE

ROOFING CONTRACTOR: FIRE SUPPRESSION CONTRACTOR:

FIRE ALARM CONTRACTOR:

Page 2: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule

PE

T S

UP

PLI

ES

PLU

S13

00 M

AC

DA

DE

BLV

D.

WO

OD

LYN

, PA

____

____

___

CONSTRUCTION DOCUMENTS

TEMPORARY UTILITIES

UTILITY FEES (DURING CONSTRUCTION)

WASTE CONTAINER/HAULING

PROJECT TYPE: PET SUPPLIES PLUS BUILD-OUT

GENERAL REQUIREMENTS0 1 2 3 4

PERMITS/APPROVAL

CERTIFICATE OF OCCUPANCY

EXTERIOR / SITE WORK

PARKING LOT LIGHTING - GOOD WORKING CONDITION

ROOF - WATERTIGHT, GOOD CONDITION

MECHANICALROOF PENETRATIONS, STRUCTURAL SUPPORT, CURBING,FLASHING (IF APPLICABLE)HVAC UNITS

HVAC DISTRIBUTION (DUCTWORK/DIFFUSERS)

THERMOSTATS & CONTROL WIRE

EXHAUST FANS AND DISTRIBUTION

SPRINKLER MODIFICATIONS (TENANT SPECIFIC DESIGN)

FIRE EXTINGUISHERS AND TAGS / SIGNS

PLUMBING1 1/2" WATER SERVICE INTO TENANT SPACE

TOILET ROOM FIXTURES

4" SANITARY

UTILITY SINK/WATER HEATER

CARPENTRYDEMISING WALL STRUCTURE

DEMISING WALLS (GYPSUM BOARD, TENANT SIDE)

MILLWORK CABINETRY

COUNTER TOPS / SHELVINGMISC. WOOD BLOCKING, FURRING, ETC.

TOILET ROOM ACCESSORIES

DOORS AND HARDWAREAUTOMATIC STOREFRONT ENTRANCE DOORS

REAR SERVICE DOORS / OVERHEAD STOCK DOOR

INTERIOR DOORS, FRAMES

FINISHESPAINT

FLOOR FINISH

VINYL BASECERAMIC TILE (FLOORS/WALLS)

FRP PANELSCEILING ( 2 x 4 LAY-IN )

ALL PIPING, FITTINGS, VENTS, ETC.

SPRINKLER SYSTEM (MAIN/BRANCHES/HEADS)

FINAL CONNECTIONS

AUTOMATIC INTERIOR VESTIBULE DOORS

REQUIRED EXTERIOR EGRESS EXIT DOOR(S)

INTERIOR PARTITIONS (STUDS / DRYWALL )

FIXTURE PLAN

2x4 BLOCKING AROUND SALES FLOOR PERIMETER

SLAB MOISTURE TEST / SLAB LEVELING

GAS PIPING TO ROOF TOP UNITS (IF APPLICABLE)SERVICE AND START-UP HVAC UNITS

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

ELECTRICAL0 1 2 3 4

PANELS / METERS

INCOMING SERVICE TO LOCATION SHOWN ON TENANT PLANSDISTRIB. BOXES, CABLES, POWER POLES

SCISSOR LIFT (IF APPLICABLE)

TEMPORARY LIGHTING

ADA CURB RAMP(S) - NEW IF NEEDED, OR EXIST. IN GOOD CONDITION

EXTERIOR BOLLARDS

CONCRETE SCISSOR LIFT PAD (IF APPLICABLE)

EXTERIOR, BUILDING MOUNTED LIGHTING

NOTES

TENANT IMPROVEMENTS

DURING CONSTRUCTION ONLY

AT NEW EGRESS DOORS AND OVERHEAD DOORS

NOTES

RECTANGULAR DUCTWORK WITH INSULATION WRAP AT ALL CONCEALED AREAS(ABOVE CEILINGS)

NOTESINCLUDING ALL REQUIRED METERING, BACKFLOW AND VALVES

SUB-METERING INCLUDING ALL REQUIRED BACKFLOW AND VALVESCONTRACTOR TO VERIFY EXACT LOCATION, SIZE, DEPTH & FLOW DIRECTIONPRIOR TO START OF WORK

GAS SERVICE AND METER

INTERIOR DISTRIBUTION & FINAL CONNECTION

JUNCTION BOXES

INTERIOR LIGHTING

EXIT AND EMERGENCY LIGHTING

TELEPHONE CONDUIT / PHONE BOARD

REGISTER P.O.S. - EQUIPMENT AND FINAL CONNECTIONS

FIRE ALARM SYSTEM - NOT REQUIRED

LOW VOLTAGE (VOICE, DATA, MUSIC) CONDUIT AND WIRE

CASH WRAP POWER POLE(S)

NOTES

1" TELEPHONE CONDUIT WITH PULL WIRE STUBBED INTO TENANT SPACE FROMMASTER TELEPHONE PANEL

INCLUDING ADDITIONAL DEVICES AS REQUIRED

FLOORS0 1 2 3 4 NOTESINTERIOR CONCRETE SLAB - MEP ROUGH-IN PROVIDE FLOOR SLAB AT PLUMBING LEAVE-OUT AREAS (MINIMUM 3000 PSI)

FLOW TAMPER SWITCHES, HEADS TURNED UP TO ROOF STRUCTURE. MODIFYSPRINKLER SYSTEM (MAIN LINES, BRANCH LINES, HEADS, TAMPER SWITCHES,ETC.) TO SUIT PSP'S LAYOUT. VERIFY EXISTING MAIN & BRANCH LINES AREHIGHER THAN 13'-0" A.F.F.

LEVEL 4 FINISH, PROVIDE FIRE ASSEMBLY RATING REQUIRED FOR PET SUPPLIESPLUS USE & OCCUPANCY. AT EXTERIOR DEMISING LOCATIONS PROVIDETHERMAL INSULATION, VAPOR BARRIER , ETC. AS REQUIRED BY CODE.

LEVEL 4 FINISHTHRU WALL PENATRATIONS AND HEAD OF WALL SEALANTS REQUIREDBY FIRE SEPARATION ASSEMBLY ALL PENETRATIONS

SOUND ATTENUATION INSULATION

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

ENVIRONMENTAL, ASBESTOS AND MOLD TESTING WITH ABATEMENTREPORT FOR THE PREMISES

CLEAN UP

DEMOLITION

PROVIDE A SLOPED RAMP FROM SIDEWALK TO PARKING SURFACE COMPLYINGWITH ALL GOVERNING ACCESSIBILITY REQUIREMENTS

ALL PENETRATION LOCATIONS & SIZES AS INDICATED ON DRAWINGS. PROVIDESTRUCTURAL SUPPORT, ROUT PENETRATIONS, INSULATED CURBS & FLASHING

RECTANGULAR DUCTWORK WITH INSULATION WRAP AT ALL CONCEALED AREAS(ABOVE CEILINGS)

HVAC DISTRIBUTION TO PUBLIC PET WASH AND SERVICE ROOMS(DUCTWORK/DIFFUSERS)

MODIFY TO SUIT PSP'S LAYOUT. VERIFY EXISTING MAIN & BRANCH LINES AREHIGHER THAN 13'-0" A.F.F.

PROVIDE CERTIFIED AIR BALANCE LETTER

DRINKING FOUNTAINS

FIRE ALARM SYSTEM - CONDUIT AND CONNECTION STUBBED TOTENANT SPACE

FIRE ALARM SYSTEM - TENANT DEVICES, FINAL CONNECTION TOLANDLORDS SYS. OR INDEPENDENT SYS. BASED ON SITE SPECIFICAPPLICATION

CONCRETE SIDEWALKS GOOD CONDITION, REPAIR AS NEEDED

DUMPSTER PAD ENCLOSURE AS REQ. BY LOCAL JURISDICTIONS & IN CLOSE PROXIMITY TO TENANTS SPACE.MINIMUM 25'Wx12'Dx7'H TRASH ENCLOSURE & SPACE INSIDE THE ENCLOSUREFOR AN 8 YARD DUMPSTER, 8 YARD CARD BOARD RECYCLE BIN & WHEELEDTOTES FOR PLASTIC RECYCLING.

STOREFRONT FACADE PATCH, REPAIR, MODIFY AS NEEDED, PROVIDED NEW, ETC.

EXISTING RECESSED OR RAISED DELIVERY DOCK IF EXISTING DELIVERY DOCK IS TO BE REUSED, PROVIDE WORK ASOUTLINED IN THESE CONSTRUCTION DOCUMENTS.

CONCRETE PAD IN FRONT OF OVERHEAD DOOR

FROST SLAB

LOADING AREALANDLORD TO PROVIDE SITE AREA & NECESSARY CONSTRUCTION TO ALLOWFOR TENANTS TRACTOR TRAILER TO ACCESS THE LOADING DELIVERY AREA

EXTERIOR WALLS

PROVIDE AT LOW PRESSING /7" W.C. & 900 TO 1100 MBH STUBBED TO TENANTSPACE

REFER TO OFFICE PLANS FOR ADDITIONAL INFORMATION

2" EMT POWER POLE AT CASH WRAPS (RAW STEEL)

INTERIOR CONCRETE SLAB - LEVELINGPROVIDE SMOOTH, UNIFORM, LEVEL FLOOR READY FOR TENANT'S FINISHES.FLOOR LEVELING AGENT TO BE COMPATIBLE WITH TENANT'S FLOOR FINISH.(MINIMUM 3000 PSI)

STOREFRONT GLAZING AND FRAMES PROVIDE THERMAL BROKEN ALUMINUM FRAME WITH 1" INSULATED GLAZING,TEMPERED. EXISTING STOREFRONT MAY BE REUSED IF IT COMPLIES WITH ALLGOVERNING CODES & IS APPROVED BY PET SUPPLIES PLUS. IF EXISTING ISREUSED, REPAIR AND CLEAN AS REQUIRED FOR LIKE NEW CONDITION.

LEVEL 4 FINISH, PROVIDE FIRE ASSEMBLY RATING REQUIRED FOR PET SUPPLIESPLUS USE & OCCUPANCY. AT EXTERIOR DEMISING LOCATIONS PROVIDETHERMAL INSULATION, VAPOR BARRIER , ETC. AS REQUIRED BY CODE. PATCH&REPAIR EXISTING WALLS TO REMAIN

PROVIDE FULL HEIGHT OF WALL WITH STC RATING OF 50 OR BETTER

PROVIDE COMPLETE VESTIBULE STOREFRONT SYSTEM WITH GYPSUM BOARD &METAL STUD WALL ABOVE ON ALL SIDES OF VESTIBULE TO UNDERSIDE OF ROOFDECK.

FURRED PARTITION ALONG DEMISING WALL-AS REQUIRED FURRED OUT DEMISING WALL TO CREATE A CONTINUOUS FLUSH WALL FROMFINISH FLOOR TO UNDERSIDE OF DECK FOR THE ENTIRE WALL LENGTH

NOTESTENANT'S SHELL SPACE (FLOOR, WALLS, ROOF, ETC) ENERGYCOMPLIANCE

TO PROVIDE TENANT'S SHELL IN COMPLIANCE WITH ALL GOVERNING ENERGYCODES.

PROVIDE CONCRETE PAD AT NEW SCISSOR LIFT LOCATION. SLOPE PAD SOWATER DRAINS AWAY FROM BUILDING. PROVIDE ALL NECESSARYCONCRETE PAD EDGE CONDITIONS PER SITE SPECIFIC REQUIREMENTS.

PROVIDE CONCRETE PAD AT NEW OVERHEAD DOOR LOCATION. (MINIMUM OF12'x12') SLOPE PAD SO WATER DRAINS AWAY FROM THE BUILDING. PROVIDEALL NECESSARY CONCRETE PAD EDGE CONDITIONS PER SITE SPECIFICREQUIREMENTS.

NOTES

NOTES

NOTES

ALL TAP, IMPACT USAGE, CONNECTION & OTHER SIMILAR FEESREQUIRED FOR TENANT'S USE & OCCUPANCY OF THE PREMISES.

TO BE PURCHASED THRU PSP'S NATIONAL VENDOR

APPROVED VENDOR PRE-WIRES DURING THE CONSTRUCTION PHASE

OFFICE AND ISOLATION ROOM

ALSO REFER TO 'TENANT/VENDOR SUPPLIED ITEMS RESPONSIBILITY SCHEDULE'FOR ADDITIONAL INFORMAITON

VESTIBULE

DIVISION OF WORK: (AS IS DEAL)ALL WORK SHOWN ON THE PLANS TO BE COMPLETED BY PET SUPPLIES PLUSS G.C. AT PET SUPPLIES PLUS'S G.C.EXPENSE UNLESS NOTED OTHERWISE

Page 3: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule
Page 4: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule

PE

T S

UP

PLI

ES

PLU

S13

00 M

AC

DA

DE

BLV

D.

WO

OD

LYN

, PA

____

____

___

PET SUPPLIES PLUS APPROVED VENDORS1. SOUND SYSTEM

MOOD-MUSAK

JASON TORRESPHONE: (512) 380-8544EMAIL: [email protected]

2. INTERIOR DECOR

DESIGN FABRICATIONS32400 INDUSTRIAL DRIVEMADISON HEIGHTS, MI 48071

MATT HARVELLPHONE: (800) 968-9440EMAIL: [email protected]

3. INTERIOR DECOR INSTALL

ENGELKE CONSTRUCTION

DAN CATHARTor SCOTT SHYMSKEPHONE: (330) 273-2222EMAIL: [email protected]: [email protected]

4. PHONE & DATA

CENTRAL COM5401 HEARTNECKVALLEY CITY, OH 44280

LARRY RUSSELLPHONE: (330) 220-0802CELL: (216) 323-5248EMAIL: [email protected]

GROOMERS CHOICE PET PRODUCTS1501 N. INDUSTRIAL AVE.SIOUX FALLS, SD 57104

RAYAN OAKSPHONE: (605) 782-0500EMAIL: [email protected]

TENANT / VENDOR SUPPLIED ITEMS RESPONSIBILITY SCHEDULE(WHITE BOX / AS-IS DEALS)

PE

T S

UP

PLI

ES

PLU

SA

PP

RO

VE

D V

EN

DO

R

14

MISC. LABOR GC TO PROVIDE 8 HOURS OF MISC. LABOR AFTER TURN OVER TO PSP FOR FIXTURE SET-UP ANDMERCHANDISING.

ITEMS OF CONSTRUCTION NOTES

WALL BUMPERS & CORNER GUARDS

16. DISPLAY FIXTURES

LOZIER FIXTURES

JOE BENADUMPHONE: (614) 793-1962EMAIL: [email protected]

5. EXTERIOR SIGNAGE

EVERBRITE, LLC4949 S. 110TH ST. GREENFIELD, WI 53228

JOHN PORTERPHONE: (414) 529-7163EMAIL: [email protected]

6. PET GROOMING/PPW EQUIPMENT 8. LOCKSMITH

BASS SECURITY SERVICES, INC.

GENEO OBERSTGIRTMAN & ASSOCIATESPHONE: (888) 774-3400 x1193 FAX: (888) 774-3500EMAIL: [email protected]

9. SECURITY SYSTEM

PROTECTION ONE

MIKE BRADFORDPHONE: (412) 913-9185

11. SCISSOR LIFT OR TOW MOTER

TOYOTA MATERIAL HANDLING5667 EAST SCHAAF ROADCLEVELAND, OH 44131

ED BOROWYPHONE: (800) 722-1211EMAIL: [email protected]

12. POS SYSTEM

RETALIX INC.797 COMMONWALTH DR.WARRENDALE, PA 15086

BOB SCHMITTPHONE: (724) 612-3409EMAIL: [email protected]

13. CART CORAL

GROUP 4 RETAIL EQUIPMENT

DORIE GUNDERSONPHONE: (800) 326-2460EMAIL: [email protected]

ELITE COATINGS LLC

TONY WOJTONPHONE: (330) 741-3003CELL: (440) 212-2430EMAIL: [email protected]

13 CART CORRAL

5 EXTERIOR SIGNAGE GC TO PROVIDE POWER CIRCUIT & SHALL MAKE FINAL ELECTRICAL CONNECTION, COORDINATE ROUGH-IN LOCATION REQUIREMENTS & TIMELY INSTALLATION WITH SIGNVENDOR. POWER TO BE PROVIDED WITHIN 5'-0" OF SIGN POWER BOXES. GC & SIGN VENDOR TO HAVE SITE MEETING TO COORDINATE PRIOR TO SIGN INSTALLATION.

2, 3 INTERIOR SIGNAGE

2, 3 INTERIOR DECOR

17 PET WASH BASIN GC SHALL SET AND SECURE TUBS TO FLOOR. MAKE FINAL PLUMBING CONNECTIONS.

6 FORCED AIR DRYERS

16 SALES FLOOR DISPLAY FIXTURES GC SHALL INSTALL SURFACE MOUNTED 2x4 FIRE RETARDANT BLOCKING ON PERIMETER WALLS FOR DISPLAY FIXTURE ATTACHMENT. REFER TO INTERIORELEVATIONS.

16 STOCKROOM STORAGE FIXTURES

15 AQUARIUM FIXTURES GC TO MAKE ALL FINAL ELECTRICAL CONNECTIONS. GC TO PROVIDE ALL PLUMBING PER VENDORS REQUIREMENTS. AQUARIUM FIXTURES SCHEDULED FOR DELIVERYAFTER TURN OVER TO PSP FOR FIXTURE SET-UP AND MERCHANDISING.

2, 3 INTERIOR RETAIL SIGNAGE

7 INTERIOR LIGHT FIXTURES AND LAMPS LIGHTING PACKAGE ORDERED BY GC FROM ELECTRICAL VENDOR AND PAID FOR BY PSP

7 EXIT & EMERGENCY LIGHTING LIGHTING PACKAGE ORDERED BY GC FROM ELECTRICAL VENDOR AND PAID FOR BY PSP

7 CASH-WRAP POWER POLES ORDERED BY GC FROM ELECTRICAL VENDOR AND PAID FOR BY GC.

TELEPHONE & DATA WIRING TO SPACE

TELEPHONE & DATA WIRING WITHIN SPACE GC TO PROVIDE CONDUIT WITH PULL WIRE PER OFFICE PLAN. REFER TO ELECTRICAL DRAWINGS.

TELEPHONE AND DATA JACK TERMINATIONS

TELEPHONE EQUIPMENT

POS SYSTEM HARDWARE

POS SYSTEM WIRING GC TO PROVIDE CONDUIT WITH PULL WIRE PER OFFICE PLAN. REFER TO ELECTRICAL DRAWINGS.

POS SYSTEM JACK TERMINATIONS

9 SECURITY SYSTEM WIRING

9 SECURITY SYSTEM DEVICES

1 MUSIC SOUND SYSTEM HARDWARE

1 MUSIC SOUNDSYSTEM WIRING

1 MUSIC SOUND SYSTEM SPEAKERS

16 CASH WRAPS

MILLWORKCASH WRAP POWER, VOICE, AND DATA

DOOR LOCKS & KEYS8

GC SHALL SECURE CASH WRAPS TO FLOOR

ALL MILLWORK (BESIDES CASH WRAPS & MILLWORK GROOMING STATION) IS THE GC'S RESPONSIBILITY

GC TO MAKE ALL FINAL CONNECTIONS.

GC SHALL SET AND SECURE DRYER TO SHELF. MAKE FINAL PLUMBING & ELECTRICAL CONNECTIONS.

MILLWORK GROOMING STATION

SCISSOR LIFT - NOT REQUIRED

FIRE ALARM - NOT REQUIRED

PROTECTION ONE

MIKE BRADFORDPHONE: (412) 913-9185EMAIL: [email protected]

7. LIGHT FIXTURES

CRESCENT ELECTRIC SUPPLY4800 VAN EPPS ROAD - SUITE 103BCCLEVELAND, OH 44131

JENNIFER ZEISELPHONE: (216) 739-6060EMAIL: [email protected]

14. WALL BUMPER/CORNER GUARDS

IMPACT SPECIALTIES

JEN MACCARTHYPHONE: (888) 424-6287FAX: (908) 849-4295EMAIL: [email protected]

SCOTT DONOHUEACCOUNT MANAGERPHONE: 216-739-6060CELL PHONE: 216-296-4156EMAIL: [email protected]

20. CERAMIC TILE

GENESEE CERAMIC TILE24260 INDOPLEX CIRCLEFARMINGTON, MI. 48335

MIKE SCHULTZPHONE: 248-478-3958CELL PHONE: 810-955-8526FAX: 248-478-7067EMAIL: [email protected]

10. STOREFRONT DOORS

RECORD AUTOMATIC DOOR SYSTEMS(RECORD-USA)

NICHOLE MCCOLLUMPHONE: 704-290-0213FAX: 704-289-2024EMAIL: [email protected]

DON HUNTER (ESTIMATOR)PHONE: 704-290-0217FAX: 704-289-2024EMAIL: [email protected]

121212

KARL COCKRELLPHONE: (805) 222-3636EMAIL: [email protected]

15. AQUARIUM FIXTURES

MARINELAND RETAILER SYSTEMS6144 CONDOR DR.MOON PARK, CA 93021

PONCH ZIZUMBOPHONE: (805) 222-3605FAX: (805) 222-3675

AMERICAN MARBLE INDUSTRIES (AMI)2700 ATLANTIC BLVD.CANTON, OH 44705PHONE: (330) 453-8437CELL: (330) 265-9972EMAIL: [email protected]

Page 5: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule

PE

T S

UP

PLI

ES

PLU

S13

00 M

AC

DA

DE

BLV

D.

WO

OD

LYN

, PA

____

____

___

1. BASED ON INTERIOR NONBEARING PARTITIONS WITH ONE LAYER OF GYPSUMBOARD EACH SIDE; USE GAUGE, TYPE AS SCHEDULED UNLESS NOTEDOTHERWISE ON DRAWINGS.

2. RUNNER TRACK GAUGE TO MATCH STUD.3. ALL WALLS SHALL HAVE 1-1/2" X16 GA, COLD ROLLED CHANNEL HORIZONTAL

BRIDGING SPACED AT 6'-0".

MAX. UNSUPPORTED HTSIZE GA. TYPE 16" O.C. 24" O.C.

NOTES 1,2,3

3 5/8" 20 15'-5" 13'-5"19'-1"18

18 28'-4"20'-3"23'-2"20

6"

16'-8"

24'-9"

INTERIORELEVATION TAG

FINISH FLOOR0'-0" A.F.F.

25 CSJ 12'-7" 11'-0"SEE NOTE 3 BELOW

SIZE PER 4" WYTHE

2'-9" TO 4'-0"

4'-1" TO 5'-6"

5'-7" TO 7'-6"

7'-7" TO 9'-6"

0' TO 2'-8"

CLEAR SPAN

L312x31

2x5

16

L4x312x

516 LLV

L5x312x

516 LLV

L5x312x

38 LLV

INTERIOR WALLS

4'-1" TO 5'-6"

5'-7" TO 7'-6"

0' TO 4'-0"

CLEAR SPAN

L4x312x

516 LLV

L5x312x

38 LLV

EXTERIOR WALLS

REMARKS

BOT ⅊ 38"

1. PROVIDE MINIMUM 3/8" THICKNESS FOR EXTERIOR ANGLES.2. PROVIDE A MINIMUM BEARING LENGTH OF 8" ON 1'-4" MIN. HT. OF GROUTED SOLID

MASONRY.3. GALVANIZE ALL LINTELS THAT ARE EXPOSED TO WEATHER.4. AT EXTERIOR WALLS, STOP BOTTOM PLATE 1/16" SHORT AT EACH END OF MASONRY

OPENING LENGTH.5. PROVIDE A MINIMUM BEARING LENGTH OF 8"6. FILL VOID BETWEEN VENEER & LINTEL WITH MORTAR TO TOP OF ANGLE.7. ANGLE MATERIAL: ASTM A36.

NOTES:

BOT ⅊ 38"

BOT ⅊ 38"

L312x31

2x5

16

7'-7" TO 9'-6"

9'-7" TO 11'-0"

NOTES:

L6x312x

38 LLV BOT ⅊ 38"

L7x4x38 LLV BOT ⅊ 38"

SIZE PER 4" WYTHE 12"BACKUP

8"BACKUP

CSJCSJCSJCSJ

ROOM NAME

SYMBOLS LEGENDINTERIOR METAL STUD SCHEDULE LOOSE LINTEL SCHEDULE

ACCESSIBILITY STANDARDS

SIGNAGE SHOULD COMPLY W/ RELEVANT GUIDELINES AS FOLLOWS.

A. ALL PERMANENT ROOM AND SPACE IDENTIFICATION SIGNAGE SHALL COMPLYWITH SECTIONS 1 THROUGH 5.

B. ALL DIRECTIONAL AND INFORMATIONAL SIGNAGE SHALL COMPLYWITH SECTIONS 1 & 2.

C. ALL IDENTIFICATION, INFORMATIONAL OR DIRECTIONAL SIGNAGE ABOUTACCESSIBLE ELEMENTS AND FEATURES SHALL COMPLY WITH SECTIONS 1THROUGH 5.

SIGNAGE DESIGN CRITERIA:

1. FINISH AND CONTRAST:CHARACTER, SYMBOLS, BACKGROUNDS SHALL HAVE A NON-GLARE FINISH.CHARACTER & SYMBOLS SHALL CONTRAST A MIN. OF 70% W/ THEIRBACKGROUND.LRV FINISH (LIGHT REFLECTANCE VALUE) OF MATERIAL FINISHES SHALL BEASTM E1349-90 OR EQUAL.

2. PROPORTIONS:CHARACTERS ARE TO HAVE A WIDTH-TO-HEIGHT RATIO OF 3:5 TO 1:1.CHARACTER STROKE WIDTH-TO-HEIGHT OF 1:5 TO 1:10.

3. RAISED CHARACTERS AND PICTORAL SIGN SYMBOLS:CHARACTER TYPE:

1/32" RAISED (MIN.)SANS SERIF UPPERCASE WITH GRADE 2 BRAILLE.

CHARACTER SIZE:MIN.5/8" AND MAX. 2" HIGH

PICTOGRAMS:ACCOMPANY W/ VERBAL DESCRIPTION PLACED DIRECTLY BELOW THEPICTOGRAM.

OUTSIDE DIMENSION OF PICTOGRAM FIELD TO BE MIN. 6" HEIGHT.CHARACTER PLACEMENT:

CHARACTERS AND BRAILLE SHALL BE IN HORIZONTAL FORMATBRAILLE SHALL BE PLACED 3/8" (MIN.) & 1/2" (MAX.) DIRECTLY BELOW THE

TACTILE CHARACTERS (FLUSH LEFT OR CENTER).IF TACTILE TEXT IS MULTILINE, ALL BRAILLE SHALL BE PLACED

TOGETHER BELOW ALL LINES OF TACTILE TEXT.4. BRAILLE:

CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER APPLICABLESTANDARDS REQUIRE BRAILLE.

DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL W/ 2/10" SPACE BETWEENCELLS, MEASURED FROM THE SECOND COLUNMN OF DOTS IN THE FERSTCELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL.

DOTS SHALL BE RAISED A 1/40" MIN ABOVE THE BACKGROUND.DOTS SHALL BE DOMED OR ROUNDED.

5. MOUNTING LOCATION AND HEIGHT:INSTALL ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.WHERE NO WALL SPACE EXISTS ON THE LATCH SIDE OF THE DOOR (INCL.DOUBLE LEAFS), PLACE SIGN ON THE NEAREST ADJACENT WALL,PREFERABLY TO THE RIGHT SIDE.

HEIGHT: 60" ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN.LOCATION: PLACE SO THE APPROACHING PERSON MAY APPROACH WITHIN3" OF SIGNAGE WITHOUT WNCOUNTERING PROTRUDING OBJECTS ORSTANDING WITHIN THE SWINGING DOOR PATH.

DOORS

A. LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH-PULL OR PANIC TYPEHARDWARE 30 INCHES TO 44 INCHES ABOVE FLOOR.

B. MAXIMUM FORCE TO OPERATE DOORS SHALL BE 5 LBS. PRESSURE. FIREDOORS SHALL BE 15 LBS. MAXIMUM.

C. FLOOR SHALL BE LEVEL AT ALL DOORS.1. THRESHOLDS: THE FLOOR OR LANDING SHALL NOTE BE MORE THAN 1/2-INCH

LOWER THAN THE THRESHOLD OF THE DOOR WAY. CHANGE IN LEVELBETWEEN 1/4-INCH AND 1/2-INCH SHALL BE BEVELED WITH A SLOPE NOGREATER THAN 1:2. (SEE BELOW).

2. LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL AND CLEAR AREA ONEACH SIDE ON AN EXIT DOOR. THE LEVEL AREA SHALL BE AS ILLUSTRATED INFIGURE A. THE SPACE BETWEEN THE TWO CONSECUTIVE DOOR OPENING(VESTIBULE) SHALL PROVIDE 48-INCHES OF CLEAR SPACE FROM ANY DOOROPENING INTO SUCH SPACE. (SEE BELOW)

D. DOOR WIDTH AND HEIGHT: 3-FEET WIDE AND 6-FEET-8-INCHES HIGH. CLEARWIDTH: 32-INCHES MINIMUM WITH DOOR OPEN 90-DEG. MEASURED FROM THEFACE OF THE DRR TO THE OPPOSITE SIDE.

E. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDINGSHALL HAVE A SMOOTH UNINTERUPTED SURFACE TO ALLOW THE DOOR TO BEOPENED BY A WHEELCHAIR FOOT - REST WITHOUT CREATING A TRAP ORHAZARDOUS CONDITION.

EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITHTHE WORDS 'EXIT'.

EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT MYMEANS OF A STAIRWAY OR RAMP SHALL BE INDENTIFIED BY A TACTILE EXIT SIGNWITH THE FOLLOWING WORDS AS APPROPRIATE:

1. 'EXIT STAIRS DOWN'2. 'EXIT RAMP DOWN'3. 'EXIT STAIR UP'4. 'EXIT RAMP UP'

EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BYMEANS OF ANEXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALLBE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS 'EXIT ROUTE'.

EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR ORHALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN SHALL BE INDENTIFIED BYA TACTILE EXIT SIGN WITH THEWORDS 'EXIT ROUTE'.

EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN

WITH THE WORDS'TO EXIT'.

PROTRUDING OBJECTS

A. PROJECTIONS FROM WALLS WITH A LEADING EDGE BETWEEN 27 INCHES AND80 INCHES ABOVE FLOOR MAY PROJECT 4 INCHES MAXIMUM. LEADING EDGEAT OR BELOW 27 INCHES MAY PROJECT ANY AMOUNT. FREESTANDINGPROJECTIONS WITH LEADING EDGE BETWEEN 27 INCHES AND 80 INCHESABOVE FLOOR MAY PROJECT 12 INCHES MAX. PROJECTIONS MAY NOTREDUCE MANEUVERING SPACE, OR CLEAR WIDTH OF AN ACCESSIBLE ROUTE.

B. PROVIDE MINIMUM OF 80 INCHES HEAD ROOM.

ELECTRICAL

A. ELECTRICAL RECEPTACLES (15, 20, AND 30 AMPS) SHALL BE AT LEAST 15INCHES ABOVE THE FLOOR.

B. SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, COOLING, HEATING ANDVENTILATING EQUIPMENT SHALL BE NOT LESS THAN 36" AND NO MORE THAN48" A.F.F.

C. FIRE ALARM INITIATING DEVISES SHALL BE 48" ABOVE THE FLOOR, GROUND ORSIDEWALK.

SANITARY FACILITIES

A. GEOMETRIC SYMBOLS1. SYMBOLS

A) MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERALTRIANGLE 1/4" THICK WITH SIDE 12" LONG AND VERTEX POINTINGUPWARD.

B) WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4"THICK, 12" DIAMETER.

C) UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK,12" DIAMETER, WITH A 1/4" THICK EQUILATERAL TRIANGLESUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER.

2. GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BECENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR ANDCONTRAST SHALL BE DINSTINCTLY DIFFERENT FROM THE COLOR ANDCONTRAST OF THE DOOR.

3. RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPAINED BYBRAILLE IN CONFORMANCE WITH SECTION 1117B.5.6. THEY SHALL BEINSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOE.WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLELEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL,PREFERABLY ON THE RIGHT. MOUNTNG HEIGHT SHALL BE 60 INCHES ABOVETHE FINISH FLOOR TO THE CENTER OF THE SIGN. MOUNTING LOCATION SHALLBE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OFSIGNAGE WITHOUT ENCOUNTERING PROTUDING OBJECTS OR STANDINGWITHIN THE SWING OF THE DOOR.

SECTION 1117B.5.6A) LETTER TYPE: LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32

INCH (0.794mm) MINIMUM AND SHALL BE SANS-SERIF UPPERCASECHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.

B) SYMBOL SIZE: RAISED CHARACTERS OR SYMBOLS SHALL BE MINIMUM OF 5/8INCH (15.9mm) HIGH.

C) PICTORAL SYMBOL SIGNS (PICTOGRAMS): PICTORAL SYMBOL SIGNS SHALLBE ACCOMPANIED BY THE EQUIVELANT VERBAL DESCRIPTION PLACEDDIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THEPICTOGRAM SHALL BE A MINIMUM OF 6 INCHES (152mm) IN HEIGHT.

B. ACCESSIBLE COMPARTMENT DOORS SHALL BE EQUIPPED WITH AN AUTOMATICCLOSING DEVICE. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOORSHALL BE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOWTHE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING OR OTHERHARDWARE NOT REQUIREING THE USER TO GRASP OR TWIST.

C. WATER CLOSET: FLUSH CONTROLS ARE TO BE OPERABLE BY AN OSCILLATINGHANDLE WITH A MINIMUM OPERATING FORCE OF 3 LB./F OR BY A LOWVOLTAGE BUTTON. THE HANDLE OR BUTTON IS TO BE LOCATED ON THE WIDESIDE SO AS TO BE OPERABLE WITHOUT REQUIREING EXCESSIVE BODYMOVEMENT.

D. URINALS: PROVIDE ALL WALL HUNG URINALS WITH ELONGATED RIM. FLUSHCONTROLS ARE TO BE HAND OPERATED AND ARE TO MEET THE SAMEREQUIREMENTS AS THE FLUSH CONTROLS FOR THE WATER CLOSET AND ARETO BE A MAXIMUM OF 44 INCHES ABOVE THE FLOOR. RIM ELEVATION TO BE 17INCHES A.F.F.

E. LAVATORY: PROVIDE AT LEAST 29 INCHES FROM THE FLOOR TO THE BOTTOMOF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING AMINIMUM OF 30 INCHES WIDE. TO 8 INCHES MINIMUM DEPTH AT THE TOP.PROVIDE FOR THE CLEARANCE AT LEAST 30 INCHES WIDE. TO 9 INCHES ABOVETHE FLOOR AND 17 INCHES DEEP FROM THE FRONT OF THE LAVATORY.PROVIDE A CLEAR FLOOR SPACE 30 INCHES x 48 INCHES IN FRON T OF THELAVAOTRY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACEUNDERNEATH THE LAVATORY. INSULATE HOT WATER AND DRAIN PIPES UNDERLAVATORIES. NO SHARP OR ABRASIVE SURFACES ARE ALLOWED UNDERLAVATORIES. FAUCET CONTROLS ARE REQUIRED TO BE OPEARABLE WITHONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THEWRIST. THE FORCE NECESSARY TO OPERATE CONTROLS IS NOT TO EXCEED 5LB./F.

F. ACCESSORIES: WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLESAND SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEASTONE OF EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDINGCOIN SLOTS, WITHIN 40 INCHES FROM THE FLOOR.

1. MOUNT MIRRORS WITH THE BOTTOM EDGE NO MORE THAN 40 INCHES A.F.F.2. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12 INCHES OF THE

FRONT EDGE OF THE TOILET SEAT.G. THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS AND MOUNTING

DEVICES SHALL MEET THE SPECIFICATIONS OF THE AMERICAN DISABILITESACT AND THE STATE OF CALIFORNIS TITLE 24.

H. SINGLE ACCOMODATION: A CLEAR FLOOR SPACE OF AT LEAST 60 INCHES INDIAMETER IS REQUIRED FOR SINGLE ACCOMODATION TOILET ROOMS.

DRINKING FOUNTAINS

CLEAR FLOOR SPACE.A. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A

FORWARD APPROACH TO THE DRINKING FOUNTAIN, SHALL BE PROVIDED. KNEEAND TOE SPACE COMPLYING WITH SECTION 306 SHALL BE PROVIDED. THECLEAR FLOOR SPACE SHALL BE CENTERED ON THE DRINKING FOUNTAIN.

EXCEPTIONS:A. DRINKING FOUNTAINS FOR STANDING PERSONS.B. DRINKING FOUNTAINS PRIMARILY FOR CHILDREN'S USE SHALL BE PERMITTED

WHERE THE SPOUT IS 30 INCHES (760 MM) MAXIMUM ABOVE THE FLOOR, AND APARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THEDRINKING FOUNTAIN, IS PROVIDED.

C. IN EXISTING BUILDINGS, EXISTING DRINKING FOUNTAINS PROVIDING APARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THEDRINKING FOUNTAIN, SHALL BE PERMITTED.

D. WHERE SPECIFICALLY PERMITTED BY THE ADMINISTRATIVE AUTHORITY, APARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THEDRINKING FOUNTAIN, SHALL BE PERMITTED FOR DRINKING FOUNTAINS THATREPLACE EXISTING DRINKING FOUNTAINS WITH A PARALLEL APPROACH

OPERABLE PARTSA. OPERABLE PARTS SHALL COMPLY WITH SECTION 309.

SPOUT OUTLET HEIGHT.A. SPOUT OUTLETS OF WHEELCHAIR ACCESSIBLE DRINKING FOUNTAINS SHALL

BE 36 INCHES (915 MM) MAXIMUM ABOVE THE FLOOR. SPOUT OUTLETS OFDRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM)MINIMUM AND 43 INCHES (1090 MM) MAXIMUM ABOVE THE FLOOR.

SPOUT LOCATIONA. THE SPOUT SHALL BE LOCATED 15 INCHES (380 MM) MINIMUM FROM THE

VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM FROM THE FRONT EDGEOF THE DRINKING FOUNTAIN, INCLUDING BUMPERS. WHERE ONLY A PARALLELAPPROACH IS PROVIDED, THE SPOUT SHALL BE LOCATED 31/2 INCHES (89 MM)MAXIMUM FROM THE FRONT EDGE OF THE DRINKING FOUNTAIN, INCLUDINGBUMPERS.

60 m

in15

25 18 min445

(a) - front approach, pull side

1220

48 m

in12 min305

(b) - front approach, push side, doorprovided with both closer and latch

36 min915

60 m

in15

25

(c) - hinge approach, pull side

42 min1065 54

min

1370

(d) - hinge approach, pull side

42 m

in *

*10

65

56022 min

(e) - hinge approach, push side* If both closer and latch are provided** 48" min. (1220) if both closer andlatch provided

30512 min * 24 min

48 m

in *

610

1220

(f) - latch approach, pull side* 54" min. (1370) if closer provided

24 min

42 m

in *

1065

610

(g) - latch approach, push side* 48" min (1220) if closer provided

60 min1525

60 m

in15

25

(a)

60 min1525

48 m

in12

20D

oor

wid

thD

oor

wid

th48

min

1220

Doo

rw

idth

60 min1525

(b)

(c)

Page 6: 1300 MACDADE BLVD. WOODLYN, PA...a6.0 interior elevations a6.1 interior elevations a6.2 interior elevations a7.0 wall sections a8.0 details a8.1 details a8.2 details a9.0 door schedule

PE

T S

UP

PLI

ES

PLU

S13

00 M

AC

DA

DE

BLV

D.

WO

OD

LYN

, PA

____

____

___

____

____

_