More than original components. The foundation of genuine quality. Straumann® Original

Transcript of More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing...

Page 1: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

More than original components. The foundation of genuine quality.

Straumann® Original

490.025_Original.indd 1 20.10.15 16:15

Page 2: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

More than lasting quality.The confidence that comes with peace of mind.

ѹ A perfectly matching system: Design harmony combined with very high manufacturing precision

ѹ Convincing in-vitro study results: Excellent fatigue test per-formance

ѹ Clinical long-term evidence: Documented constant clinical success

ѹ Continuing trust in Straumann implants: Assured availability of prosthetic components

ѹ Straumann’s service excellence: Exceptional service and sup-port including the Straumann Guarantee

WHEN YOU CHOOSE STRAUMANN COMPONENTS YOU RECEIVE A HIGH-PRECISION PRODUCT OF A SELECTED QUALITY.

490.025_Original.indd 2 20.10.15 16:15

Page 3: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

1

Prof. Dr. Urs Belser, Chairman emeritus, Department of Fixed Prosthodontics and Occlusion of the University of Geneva School of Dental Medicine, Switzerland

STRAUMANN ORIGINAL COMPONENTS – DEPENDABLE VALUES THAT KEEP CONVINCING DENTAL PROFESSIONALS WORLDWIDE:

Globally we look back on an almost 40-year clinical success story with Strau-mann implants and Straumann prosthetic components. The exclusive use of original components has been my choice for the last 25 years, because all patients deserve both uncompromising quality and low risk taking.

490.025_Original.indd 1 20.10.15 16:15

Page 4: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

2

More than high precision.System design in perfect harmony.

Only Straumann* knows exactly the dimensions, toler-ances and material composition of its implants, and can therefore produce optimal design harmony between Straumann implants and their corresponding Straumann prosthetic components.

High-precision manufacturing and an exceedingly thor-ough inspection process ensure a consistent quality of all original Straumann components.

Features Benefits

1 Conical screw head …

2 Radial contact surfaces …

3 Tight conical implant- abutment interface …

4 Deep implant- abutment engagement …

… no peak stresses

… precise guidance at assembly

… sealed implant-abutment connection

… high stability

1

23

4

THE ORIGINAL STRAUMANN IMPLANT-ABUTMENT INTERFACE – RE-MARKABLE PERMANENCE AND DURABILITY YOU CAN FULLY RELY ON

490.025_Original.indd 2 20.10.15 16:15

Page 5: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

3

3

4

2

1

*COMPATIBLE IS NOT ORIGINAL.

Straumann® CARES® Ti Abutment on Straumann® RC 4.1 Implant

NobelProcera™ CAD/CAM Ti abutment on Straumann® RC 4.1 Implant

Atlantis™ CAD/CAM Ti abutment on Straumann® RC 4.1 Implant

The Original Third-party abutments claimed as compatible

WHICH ONE DO YOU TRUST IN?

490.025_Original.indd 3 20.10.15 16:15

Page 6: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

4

490.025_Original.indd 4 20.10.15 16:15

Page 7: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

5

The perfect match of Straumann implants and abut-ments results in an excellent fatigue test performance. In the following studies we will show you the differ-ence between Straumann original components and non-original components in two crucial respects:

More than a statement.Proven performance.

ѹ Screw loosening ѹ Variation in micro mobility

ORIGINAL QUALITY – THE DIFFERENCE IS OBVIOUS.

490.025_Original.indd 5 20.10.15 16:15

Page 8: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

6

[Ncm

]

30

40

20

10

0

There is a difference in screw loosening of original versus non-original implant-abutment connections.

Test method: ѹ Abutments were tightened on the implants with 35 Ncm. ѹ Cyclic loading with 150 N at 30° for 1 million cycles was applied. ѹ Removal torque values were measured after cyclic loading.

Removal torque value after cyclic loading

Screw loosening after cyclic loading1

Prof. Seong Joo Heo, Depart-ment of Prosthodontics and Dental Research Institute, College of Dentistry, Seoul Na-tional University, Seoul, Korea

Our study shows that the tested original components fit better at the implant-abut-ment interface than non-original compo-nents. The consequence is a reduced risk of screw loosening and of implant-abutment fractures.

Straumann® SLA® RN 4.1 – Straumann® Solid Abutment

Straumann® SLA® RN 4.1 – Lifecore® Biomedical Restore, Inc RDS COC abutment

Straumann® SLA® RN 4.1 – Neobiotech® Neoplant solid abutment

Straumann® SLA® RN 4.1 – Osstem AVANA solid abutment

THE ORIGINAL STRAUMANN ABUTMENT-IMPLANT SYSTEM SHOWS THE SMALL-EST EFFECT OF SCREW LOOSENING – REFLECTED BY THE HIGHEST REMOVAL TORQUE2 AFTER CYCLIC LOADING.

490.025_Original.indd 6 20.10.15 16:15

Page 9: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

7

8

12

16

4

0

-4

Implant-abutment mobility at 120 N

Dis

tanc

e ch

ange

bet

wee

n re

fere

nce

poin

ts a

fter

load

ing

[µm

]

Test method: ѹ 2 reference points* were chosen, one at the implant and one at the abutment. ѹ A load of 120 N was applied with a set up according to ISO 14801. ѹ The change in distance between the 2 reference points* was measured by optical methods.

Dr. Ludger Keilig, Department of Prosthetic Dentistry, Preclin-ical Education and Materials Science, Dental School, Univer-sity of Bonn, Germany

Our study showed that the use of the original Straumann abutments resulted in a reproducible high stability of the im-plant-abutment connection compared to the third-party abutments.

There is a difference in variation of micro mobility of original versus non-original implant-abutment connections.

Variation of micro mobility3

Straumann® BL RC 4.1 on Straumann® CARES® Ti Abutment

Straumann® BL RC 4.1 on ATLANTIS™ CAD/CAM abutment

Straumann® BL RC 4.1 on Nobel Procera™ CAD/CAM abutment

THE ORIGINAL STRAUMANN IMPLANT-ABUTMENT SYSTEM SHOWS THE SMALLEST VARIATION OF MOBILITY* (SMALLEST BOX PLOTS) – INDICATING THE TIGHTEST TOLERANCE LIMITS OF THE IMPLANT-ABUTMENT INTERFACE.

* The mean implant-abutment mobility was between 2 and 4 µm for all abutment types (not significant for p = 0.05).

490.025_Original.indd 7 20.10.15 16:15

Page 10: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

8

Thanks to consistent evidence-based research, continuous optimizations and our passion for quality, we have made a crucial contribution to making im-plant dentistry safer.

In the following clinical study by the University of Bern we will show you that Straumann original prosthetic components come with a striking long-term performance.

Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK

The quality of the Straumann prosthetics is the reason I have been using them for more than 15 years. I know I can rely on the Straumann products and I can pass on this confidence to our clinicians.

With an almost 40-year clinical success story, Straumann implants and their corresponding Straumann prosthetic components have prov-en to stand the test of time – in an impressive and convincing way.

More than a clinically proven system.It’s the trust that comes with it.

490.025_Original.indd 8 20.10.15 16:15

Page 11: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

9

490.025_Original.indd 9 20.10.15 16:15

Page 12: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

10

STRAUMANN ORIGINAL5 PROSTHETIC COMPONENTS SHOW EXCELLENT LONG-TERM CLINICAL PERFORMANCE.

Complications

Success

2.57 %Occlusal screw loosening n = 10

0.26 %Abutment loosening n = 1

0.26 %Occlusal screw fracture n = 1

0.26 %Abutment fracturen = 1

3 %n = 13

SUCCESS RATE OF STRAUMANN PROSTHETIC SECONDARY COMPONENTS

A 10-year retrospective study on Straumann original prosthetic components4

97 %n = 375

490.025_Original.indd 10 20.10.15 16:15

Page 13: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

11

Test method: ѹ 10-year retrospective clinical study to assess the rate of

mechanical and technical complications and failures with implant-supported fixed dental prostheses.

ѹ Prosthetic restorations on all 388 surviving Straumann® Tissue Level Implants were assessed. The implants had been restored with original Straumann components5 between May 1997 and January 2001 in the University of Bern.

THE 97 % SUCCESS RATE THAT STRAUMANN ORIGINAL PROSTHETIC SECONDARY COMPO-NENTS SHOW AFTER 10 YEARS UNDERLINES THE EXEMPLARY AT-TRIBUTES OF STRAUMANN COMPONENTS.

490.025_Original.indd 11 20.10.15 16:15

Page 14: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

12

Final crown immediately after insertion

Photos by courtesy of: Dr. Dr. Stefan Lienhard, Dr. E. Christian Schmid, and Siegfried Eich (dental technician) and Michael Vielreicher (master dental technician) from Frank Dentaltechnik GmbH

More than availability. Our commitment to continuity.

With Straumann® Classic we take care of millions of patients world-wide, who have had placed Straumann implants with original Strau-mann prosthetic components. By making available exactly matching prosthetic components for all our implants from as early as 1974, pa-tients, dentists and dental labs can put aside one considerable source of trouble in repeat restorations.

Initial situation: Occlusal screw fracture of a 24-year old Straumann type-F implant in regio 21. The screw fragment was stuck in the implant thread. The former dentist assumed pros-thetic components are not available anymore and solved the case with a clasp prosthesis. The patient was unhappy with this situation and therefore asked for a better solution.

Treatment plan: The screw fragment was removed with sup-port from Straumann. Thanks to the Straumann® Classic pro-gram the implant could be provided with the needed prosthetic components.

Final result: The case was restored with a state-of-the-art all-ceramic crown.

490.025_Original.indd 12 20.10.15 16:15

Page 15: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

13

Dentist Dr. E. Christian Schmid, Neutraubling/Germany and Patient

1 Kim SK, Koak JY, Heo JS, Taylor TD, Ryoo S, Lee SY: Screw loosening with interchangeable abutments in internally connected implants after cyclic load-ing. Int J Oral Maxillofac Implants 2012; 27:42-47 2 Results for Straumann abutments on Straumann implants are statistically different from those with non-original parts. 3 Keilig L, Berg J, Söhnchen P, Kocherovskaya, Bourauel C. Micro-mobility of the implant/abutment interface for original and third-party abutments – a combined experimental and numerical study (Poster EAO 2013, Dublin, ref. no. 346). 4 Wittneben JG, Buser D, Salvi GE, Bürgin W: Compli-cation and failure rates with implant-supported fixed dental prostheses and single crowns: A 10 y retrospective study. Clin Implant Dent Relat Res 2013; (E-pub ahead of print). 5 pers. comm. Dr. Wittneben: For 278 out of the 303 patients 100% original Straumann prosthetic components could be verified, 25 patients could not be reached anymore as dentists were retired. 6 For applicable terms and conditions of the Straumann Guarantee (including the Guarantee territory) please refer to the Guarantee brochure (152.360/en) or visit your local Straumann website. 7 The Online Verification Tool may not be available on all local Straumann websites. You can always access it via the following link: www.straumann.com/en/online-verification-tool

It became obvious to me how crucial it is to have the right prosthetic components avail-able. In this matter, Straumann clearly con-vinced me. Dentist

I’m delighted about the new crown on my implant that I’ve had for 30 years. Losing my tooth had been so traumatic, I was glad the gap could be closed at all without damaging my healthy teeth. I’m now happier than ever the clinic gave me a Straumann implant. Patient

490.025_Original.indd 13 20.10.15 16:15

Page 16: More than original omponents · Ashley Byrne, BSc (hons), RDT, Byrnes Dental Laboratory, Managing Director, Oxford, UK. The quality of the Straumann prosthetics is the reason I have

International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 www.straumann.com

Restore® RDS COC Abutment is a registered trademark of Lifecore Biomedical Inc, USA. Neoplant Solid Abutment is a brand of Neobio-tech Co. Ltd., KR. AVANA Solid Abutment is a brand of Osstem Co. Ltd, KR. NobelProcera™ and NobelReplace® are trademarks or registered trademarks of Nobel Biocare, Switzerland. OsseoSpeed™ and Atlantis™ are trademarks of Dentsply IH AB, Sweden or its subsidiaries.

© Institut Straumann AG, 2015. All rights reserved.Straumann® and/or other trademarks and logos from Straumann® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. 49

0.02

5/en

/B/0

0 0

8/15

Easily identify original Straumanncomponents with our:

ѹ Online Verification Tool7

ѹ Enlarged logo on our Titanium Abutments ѹ Seal of quality on all original components

packagings

Have all the essential information on Straumann components available with the practical pocket-size implant passport.

Straumann's service excellenceWHEN YOU DECIDE TO TRUST STRAUMANN ORIGINAL COMPONENTS, YOU’LL DECIDE FOR THE EXCEPTIONAL SERVICE AND SUPPORT.

Benefit from the Straumann Guarantee as we grant you:

ѹ a lifetime guarantee for implants6, ѹ a 10-year guarantee for metal restorations6 and ѹ a 5-year guarantee for ceramic restorations6

AVOID SURPRISES – DEMAND QUALITY: CHOOSE ORIGINAL STRAUMANN COMPONENTS.

490.025_Original.indd 14 20.10.15 16:16