M1100 Series Oxygen Monitor - AAVOS International · 2017. 11. 10. · M1000 Oxygen Monitor M1100...

2
M1000 Oxygen Monitor M1100 Series Oxygen Monitor Specialist in preventing dust explosions The Monox1000 SX.IS Monitor is designed as an in situ oxygen monitor sensor/transmier for inert applicaons in silo’s, trans- port systems, tanks and bins of for example chemical powders, which have a potenal risk for a dust explosion. The atmosphere in the silo or bin is inersed with N2 (or CO2) with the result that due to the low oxygen concentraon no ex- plosions can occur. To ensure that the oxygen gas concentraon is maintained within the specified limits it is necessary to monitor and control the nitrogen (N2)-dosing process. Since the environment is mostly very dusty it is not very advisable to use a sampling system with a pump. The dust will frequently block the tubing and filters of the sam- pling system, causing a high level of maintenance. Due to the patented operang principle of the Monox1000, the chemical powder does not block the sensor. This results in a very reliable system and a long term maintenance free operaon. Field of application SILO’S, BINS, transport systems or other inersed SYSTEMS with chemical powders, sugar dust, flour that use nitrogen (to prevent a dust explosion). Optional • Automac Calibraon System (product sheet on request) • UPS, Uninterruptable Power Supply (product sheet on request) Advantages • No sampling system required • No maintenance • Economic advantage: reduces spillage of nitrogen • No pumps or filters • No moving parts • Significant savings in N2 consumpon (at inert systems) • Increases safety Successfully installed by • Momenve Speciality Chemicals • Shell Chemical Pernis • Sabic The Netherlands • Sabic Spain • Sabic China • Sabic V.S. • Cerexagri B.V. / Uniphos • EMDE Industrie-Technik GmbH Method of use / Safety recommendations See manual M1000 & www.steuma.com Certificates ATEX: Ex II 2 GD EEx d IIC T4 (Tmax 125°C) UL classI, div.1, groups A,B,C en D UL classII, div.1, groups E,F en G

Transcript of M1100 Series Oxygen Monitor - AAVOS International · 2017. 11. 10. · M1000 Oxygen Monitor M1100...

Page 1: M1100 Series Oxygen Monitor - AAVOS International · 2017. 11. 10. · M1000 Oxygen Monitor M1100 Series Oxygen Monitor Specialist in preventing dust explosions The Monox1000 SX.IS

M1000Oxygen Monitor

M1100 SeriesOxygen Monitor

Specialist in preventing dust explosions

The Monox1000 SX.IS Monitor is designed as an in situ oxygen monitor sensor/transmitter for inert applications in silo’s, trans-port systems, tanks and bins of for example chemical powders, which have a potential risk for a dust explosion.

The atmosphere in the silo or bin is inertised with N2 (or CO2) with the result that due to the low oxygen concentration no ex-plosions can occur. To ensure that the oxygen gas concentration is maintained within the specified limits it is necessary to monitor and control the nitrogen (N2)-dosing process.

Since the environment is mostly very dusty it is not very advisable to use a sampling system with a pump.

The dust will frequently block the tubing and filters of the sam-pling system, causing a high level of maintenance. Due to the patented operating principle of the Monox1000, the chemical powder does not block the sensor. This results in a very reliable system and a long term maintenance free operation.

Field of application

SILO’S, BINS, transport systems or other inertised SYSTEMS with chemical powders, sugar dust, flour that use nitrogen (to prevent a dust explosion).

Optional• Automatic Calibration System (product sheet on request)• UPS, Uninterruptable Power Supply (product sheet on request)

Advantages• No sampling system required • No maintenance• Economic advantage: reduces spillage of nitrogen• No pumps or filters• No moving parts• Significant savings in N2 consumption (at inert systems)• Increases safety

Successfully installed by

• Momentive Speciality Chemicals• Shell Chemical Pernis• Sabic The Netherlands• Sabic Spain• Sabic China• Sabic V.S.• Cerexagri B.V. / Uniphos• EMDE Industrie-Technik GmbH

Method of use / Safety recommendations

See manual M1000 & www.steuma.com

Certificates

ATEX: Ex II 2 GD EEx d IIC T4 (Tmax 125°C)UL classI, div.1, groups A,B,C en DUL classII, div.1, groups E,F en G

Page 2: M1100 Series Oxygen Monitor - AAVOS International · 2017. 11. 10. · M1000 Oxygen Monitor M1100 Series Oxygen Monitor Specialist in preventing dust explosions The Monox1000 SX.IS

Technical Data

The Monox1000 is designed as a 4..20 mA transmitter type instrument with digital dis-play for the measured oxygen concentration. This concentration is the input for a system to control the inertisation.

The oxygen sensor is built in a pressure proof and stainless steel housing. The transmitter housing is made out of aluminium, and is splash waterproof and HF-shielded. The monitor is mounted on a flange which is located at the top of the silo or bin.

The Monox1000 SX.IS is intrinsically safe according to Ex II 2 GD EEx d IIC T4 (Tmax 125°C)IP6X with certificate number ISSeP 03ATEX140.

Technical Specifications

Measuring range 0 .. 25% O2

Display 3 ½ digit LCD

Accuracy +/- 2%

Repeatability +/- 2% of measuring value

Zero drift 0,5 % / month

Measuring principal electrochemical

Response time (T90) < 10 s sensor life ca. 2 year

Temperature range -15 .. +40 grC

Humidity range 15 .. 99 % R.H., non condensing

Process pressure +/- 100 mbar compared to atmosphere

Interfering gasses strongly oxidising gasses, H2 (<-2%), CO (<-0.5%)

Electrical power 24 VDC

Output signal 2-wire, 4 .. 20 mA, linear

Dimensions 180x206x80mm

Weight 2,5 kg

Process flange standard SS316, 2” ANSI B 16,5 Class 150 Flange

Calibration gas fitting 1/8”NPT

M1000 Series | Oxygen Monitor

Sales
Getypte tekst
AAVOS International bvba – Sparkevaardekenstraat 3, B-8600 Diksmuide Belgium www.aavos.be [email protected] T. +32 (0)51 69 78 15 F. +32 (0)51 69 78 17
Sales
Getypte tekst
Your partner in process analyses More than 20 years of experience