LSM-TU-HF 7 - TECH ISSUE002
Transcript of LSM-TU-HF 7 - TECH ISSUE002
An electric mechanism to lift a flat screen television. Shown for
use with a Telescopic Unit and Heavy Duty Electric Flap Unit.
Suitable for a total lifting weight of 30Kg [66Ibs]
Maximum Screen Height 920mm [36.2]
Maximum Screen Depth 60mm [2.4]
Maximum Lift Distance 1495mm [58.9] (Top edge of
screen to cabinet top)
Lift systems to suit different screen heights are available.
Check screen mounting details and request a suitable mount plate
Supplied with basic infraredremote. Can be learnt by
many learning remotes.
Also has switch control andRS232 so can be operated by
relays, switches, Crestron /AMX or Lutron systems.
It is the responsibility ofthe installer to warn allpotential end users of
the dangers of interferingwith mechanisms during
operation
WARNING IMPORTANTMechanisms which liftor move weights need
to be checked on ayearly basis for anydamage which mayresult in an accident
CONTROL
SPECIFYING
SUITABILITY
FUNCTIONDESIGN HIGHLIGHTS
Quiet smooth action at •approximately 40mm [1.6] per second
Full cable management•
Wide range of mounting options•
24V DC motor. Suitable for direct •DC supply
Robust lifting beam•
OPTIONS
Heavy duty option•
NON-TELESCOPIC OPTIONS
Box Enclosure with Swivel•
Box Enclosure•
Advance & Rotate•
Custom screen back cover•
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 1 of 9
Telescopic Unit
Safety push rod to avoid finger trapping in flap
Cable management
Heavy Duty Electronic Flap unit(HF) Opens flap before lifting the screen
Robust lifting beam
Safety switched base
Screen Mount PlatesSuitable for VESA 400, 300 & 200 mounting patterns
Design HighlightsA space efficient and robust lifting mechanism.
A robust 24V DC motor with a purpose made lead screw enables a quiet and smooth lifting action at approximately 40mm [1.6] per second.
High precision linear guideways ensure stability and durability of the beam to prevent any unwanted movement of the screen.
Adjustable UP and DOWN positions allow for a precise final setup within the cabinet.
The safety switched base reduces the risk of damage to the mechanism or injury to the user by cutting power to the motor when there is an obstruction between the cabinet and base panel.
Full cable management protects all screen and power cables from damage and is easily accessible for future changes to the AV setup.
A wide range of mounting options are available to suit different screens and speaker arrangements.
The Heavy Duty Flap Actuator mechanism eliminates the need for a lid or box to be mounted around the screen.
The Telescopic Unit allows the screen to be lifted a further 575mm [22.6], producing a Maximum Lift Distance of 1495mm [58.9].
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 2 of 9
7.9
200
23.6600
A
Screen Cables enter the top of the Telescopic Unit and are fed down through the Cable Track within. This can be accessed by removing the two front covers of the Telescopic Unit. The cables then pass through the LSM Beam and into the LSM Cable Track. Cables must be routed carefully to prevent any interference with the LSM beam as it operates.
Screen and Mechanism cables should be routed to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom.
Recommended cable exit point
Conduit
CL
To Mains Power
Screen Cables enter the Telescopic Unit here
DETAIL A Cables exit beam and enter cable track
LSM Beam
LSM Cable Track
KK
Maximum Possible Depth of Conduit 38mm [1.5]
TOP VIEW
8.3210
2.052
5.9150
Control Box
Cable Routing
SCREEN CABLEMECHANISM CABLEPOWER CABLE
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 3 of 9
41.71060
InternalCabinetHeight
0.820
Max Thicknessof Base andCabinet Top
0.820
0.820
Internal Cabinet Width = Screen Width + 180 [7.1]Minimum Width = 1000 [39.4]
58.91495
MaximumLift Distance
2.870
A
A
0.13
0.820
Minimum Distancefrom Screen toEdge of Base
36.2920Max
ScreenHeight
6.1154
5.5141
Back ofMechanism
to Mount
B
SECTION A-A
0.820
Aperture Depth =Screen Depth + 140 [5.5]
Minimum 150 [5.9]Maximum 200 [7.9]
DETAIL B
Flaphingepoint
Mechanism Up - In Cabinet
IMPORTANT: Thicker cabinet tops will require a reduced maximum screen heightwww.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 4 of 9
41.71060
InternalCabinetHeight
0.820
MaximumThickness
of Base andCabinet Top
5.5140
Minimum ScreenHeight from Base
of Cabinet 0.820
0.410
Minimum Distancebetween Screenand Cabinet Top
B
B
Aperture Width =Screen Width +46mm [1.8]
Aperture Depth =Screen Depth + 140 [5.5
Minimum 150 [5.9]Maximum 200 [7.9]
Maximum Flap Weight 5Kg [11Ibs]
36.2920Max
ScreenHeight
6.5165
5.5141
Back ofCabinet to
Mount
SECTION B-BIMPORTANT: Thicker cabinet tops will require a reduced maximum screen height
Mechanism Down - In Cabinet
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 5 of 9
Flap Panel Width = Cabinet Aperture Width -6mm [0.25]
FLAP PANEL - BOTTOM VIEW
HINGE SIDE
Base Panel Width = Cabinet Aperture Width -6mm [0.25]
15.7400
3.590
3.0
75
0.820
BASE PANEL - TOP VIEW
Cut-out for HF Push Rod
VIEWING SIDE
VIEWING SIDE
CL
0.820
Base Panel Depth =Cabinet Aperture
-34mm [1.34]Minimum 116mm [4.6]Maximum 166mm [6.5]
Flap Panel Depth =Cabinet Aperture
-6mm [0.25]Minimum 144mm [5.7]Maximum 194mm [7.6]
M
0.12
0.410
0.410
DETAIL M
Base Panel and Flap Panel DetailsFlap depth dimensions are based on a 3mm thick piano hinge
Required flap dimensions may vary dependant on the hinge used
IMPORTANT: Flap Panel weight must not exceed 5Kg [11Ibs]
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 6 of 9
41.31050
Highest PossibleCentreline of Mount
15.7400
15.7400
CL
15.7400
11.8300
7.9200
33.9860
Lowest PossibleCentreline of Mount
15.7400
CL
Screen Mount AdjustabilityA standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 7 of 9
D
The Flap Panel is attached to a hinge at the back of the cabinet aperture.
The HF Unit is fixed to the rear face of the cabinet with wood screws.
The LSM is fixed to the back of the cabinet with wood screws in each corner
The outer limits of the travel of the actuator can be adjusted to alter the Open and Closed positions of the Flap.
DETAIL D
The Flap Plate is attached to the under side of the Flap and fixings are concealed with a magnetic Cover Plate
Mechanism Installation Overview
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 8 of 9
41.71060
17.8451
20.7525
41.71058BackPlate
Height
6.1154
92.62353
29.3745
32.5826
23
.058
5
6.2158
6.5165
MECHANISM - UP POSITION
MECHANISM - DOWN POSITION
Overall Mechanism Dimensions
www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
LSM TU HF 7 - Lift System Telescopic - Electric Heavy Flap Technical SheetISSUE 002
SHEET 9 of 9