London Tideway Tunnels
Modernising London’s Sewerage System
Rob Furniss
AECOM Water
Global Director of Community Infrastructure
![Page 2: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/2.jpg)
The Background to London’s Sewers
![Page 3: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/3.jpg)
1848 – Cholera deaths peak In London1858 - The Great Stink – Parliament suspended
12000
14000
16000
London Cholera Deaths
0
2000
4000
6000
8000
10000
1831 1833 1848
3
![Page 4: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/4.jpg)
“Lost” rivers of London
River Roding
Barking Creek
Stoke NewingtonHampstead
BowIslington
Waterloo
Black
DitchErith
Notting Hill
Bev erley B rookBev erley B rookBev erley B rookBev erley B rook
8383
Forest Hill
Roehampton
Streatham
Eltham
WoolwichWaterloo
Battersea
Chelsea
4
![Page 5: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/5.jpg)
Plan
London’s Sewers - Evolution and Complexity
Original sewers and local collectors River
Wall
RiverThames
Section
High Tide
Low Tide
Storm relief sewers and pumping station
Bazalgette’s Interceptor Sewers
Thames
Ground level
5
![Page 6: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/6.jpg)
Intercepting sewers
Central LondonIntercepting Sewersat the present day
Hampstead
StokeNewington
Notting Hill
Bow
Waterloo
Abbey MillsPumping Station
Middle Level No. 1
PiccadillyBranch
High Level
Western
BermondseyBranch
Wick
Do
gs B
ran
ch
Lo
w L
evel
Northern
Northern Outfall
Sou
Isle
of
thern Outfall No. 1
NorthernLowLevelNo. 1
Lan
eB
ranch
LowLevel No. 2
Middle Level No. 2
Southern Outfall No. 2
Islington
Western Pumping
Station
CrossnessPumping Station
Sewer
3288-03/127
Roehampton
Streatham
ForestHill
Eltham
Woolwich
DeptfordPumpingStation
Western
Fulham
Branch
High LevelExtension
Southern
Low Level
SouthernHigh Level No. 1
Effra B
ran
ch
mondsey
Branch Southern Outfall No. 1
SouthernLow L
evel No. 2
Lewish
am
Bra
nch
Sou
Hig
h L
evel
No. 2
ther
n
Southern Outfall No. 2No. 1
Western Pumping
Station
6
![Page 7: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/7.jpg)
1859 – 1865 Construction of Bazalgette’s new interceptor sewers
Northern Outfall Sewer Sewer tunnels
7
![Page 8: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/8.jpg)
The Victorian legacy
8
![Page 9: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/9.jpg)
After 150 years …….an Upgrade is Required
![Page 10: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/10.jpg)
Urban Wastewater Treatment Directive
10
![Page 11: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/11.jpg)
London’s sewerage system today – mostly combined
Beckton STW
Crossness STW
Separate system
Partially separate system
Combined system
Percentage Connected
Crossness STW
11
![Page 12: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/12.jpg)
Distribution of impermeability in the Thames Tideway catchment
12
![Page 13: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/13.jpg)
Combined Sewer Overflows (CSOs)
• Sir Joseph Bazalgette’s sewerage system constructed with 57 CSO
points along the tidal River Thames.
• CSOs prevent flooding to buildings and streets by diverting excess
sewage into the river when full to capacity after rainfall.
• On average, in excess of 32 million tonnes of untreated sewage is
estimated to be discharged annually.
• Discharges occur more than once a week on average.
• Many sewers run 80% full on dry weather flow
• As little as 2mm of rainfall can trigger a discharge.
13
![Page 14: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/14.jpg)
57 existing Combined Sewer Overflows
14
![Page 15: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/15.jpg)
Existing Combined Sewer Overflows
15
![Page 16: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/16.jpg)
Discharging CSO
16
![Page 17: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/17.jpg)
London Tideway Tunnels - CSOs proportion of discharge
17
![Page 18: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/18.jpg)
Thames Tunnel CSOs proportion of discharge
18
![Page 19: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/19.jpg)
Increasing recreational use of River Thames
19
![Page 20: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/20.jpg)
Headline news
20
![Page 21: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/21.jpg)
The SolutionThe London Tideway Tunnels
![Page 22: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/22.jpg)
Solutions?
Action before sewer: Source Control &
Sustainable Urban
Drainage Systems
(SUDS)
NO
Within sewer network:
Localised storage &
separation.
NO
In-river: More ‘Bubbler’ &
‘Skimmer’ vessels. NO
Intercept overflows:
central storage &
transfer.
YES
22
![Page 23: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/23.jpg)
Pump out toBeckton STW
Crossness
Abbey
Mills PS
Houses of
Parliament
Tower ofLondon
Thames Barrier
The Thames and Lee tunnels Option 1c
This figure is indicative only and subject to site selection process and further design work
Earl PS
Greenwich PS
Proposed Lee Tunnel
Proposed Thames Tunnel
Combined Sewer Overflow (CSO) Pumping station
Combined Sewer Overflow (CSO) Gravity
Sewage treatment works
Pumping station
CrossnessSTW
WesternPS
Heathwall PS
HammersmithPS
STW
PS
23
![Page 24: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/24.jpg)
CSO Interception
Section
High Tide
Low Tide
Ground level
Main tunnel
Interception chamber and drop shaft
Connection tunnel
24
![Page 25: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/25.jpg)
London Tideway Tunnels
Thames Tunnel
Lee Tunnel
• 6.9km tunnel from Abbey Mills Pumping Station to Beckton STW.
• £400m project. Largest single contract ever awarded by Thames Water.
• Will intercept 16 million cubic metres of storm sewage that currently makes its way into the River Thames.
• 32.2km (20 mile) tunnel from west London to Beckton Sewage Treatment Works.
• Starting point still to be determined, major shaft sites and combined sewer overflow
connection points required.
• Planning application to be submitted 2011.
• Construction not expected to start until 2012/13 for completion by 2020.
Thames Tunnel
25
![Page 26: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/26.jpg)
10
0
-20
-30
-40
-50
-10
10
0
-20
-30
-40
-50
-10
ELE
VA
TIO
N (
mO
D)
RIV
ER
TH
AM
ES
BE
CK
TO
N O
VE
RF
LO
W S
HA
FT
BE
CK
TO
N P
UM
PIN
G S
HA
FT
Lee Tunnel - general geology
-100
-60
-70
-80
-90
-100
-60
-70
-80
-90
ELE
VA
TIO
N (
mO
D)
MADE GROUND / ALLUVIUM RIVER TERRACE GRAVEL LONDON CLAY FORMATION HARWICH FORMATION
LAMBETH GROUP THANET SAND FORMATION WHITE CHALK SUBGROUP
KEY TO GEOLOGY
THE GREENWICH FAULT ZONE
‘THE PLAISTOW GRABEN’
1+
090
6+
061
6+
904
3+
905
2+
591
1+
491
1+
936
3+
126
3+
409
4+
831
5+
468
0+
587
0+
000
CHAINAGE
GEOLOGICAL FAULT
POSITION OF MID LAMBETH GROUP HIATUS BOREHOLE AND DESIGNATION
(PHASE 1, PHASE 2) 26
![Page 27: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/27.jpg)
![Page 28: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/28.jpg)
![Page 29: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/29.jpg)
Thames Tunnel – ground conditions
29
London ClayThanet Sands and Lambeth
BedsChalk
29
![Page 30: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/30.jpg)
Tideway Tunnels – 8.8m OD tunnel boring machine (TBM)
Technical challenges
• Tunnel-to-tunnel connections
beneath river
• Lining durability - 150 yr design life
• Transient pressure waves
30
Earth Pressure Balance Machine
• Aquifer protection
• Proximity to other tunnels
• Settlement impact on third parties
• Construction logistics: 80m water
pressure through chalk/very long
drives
![Page 31: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/31.jpg)
Ground investigations
31
![Page 32: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/32.jpg)
Challenges
• 34 CSOs
• Up to 60m3/s
• Up to 30m dia
shafts
• Up to 75m deep
CSO interception
• Up to 75m deep
• De-aeration
• Air release
• CSO interception
in river or busy
London Streets
32
![Page 33: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/33.jpg)
Assessment of fluvial impact of works
33
![Page 34: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/34.jpg)
Operation and maintenance - purpose made inspection vehicle in Milwaukee sewer tunnel
34
![Page 35: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/35.jpg)
The search for shaft sites
35
35
![Page 36: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/36.jpg)
Consultation
Page 3636
![Page 37: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/37.jpg)
Timeline
Reportto
Government
Dec 2006
Planningapplication
ThamesTunnel
2011
CommissionThamesTunnel
2020
Consultation began
Autumn 2008
Public consultation on preferred sites
Mid 2010
Minister’sdecision
Mar 2007
ThamesTunnel
contract awards
2012
Site identification
Spring-Autumn 2009
Finalise list of sites
Summer 2010
Planning application
Lee Tunnel
& Beckton STW
May 2008
LeeTunnel
contractaward
Early 2010
CommissionLee
Tunnel&
Beckton STW
2014
37
![Page 38: London Tideway Tunnels Modernising London’s Sewerage … 1/1.1 AECOM Tideway... · 2010-06-02 · London Tideway Tunnels Modernising London’s Sewerage System ... London Tideway](https://reader031.fdocuments.net/reader031/viewer/2022022015/5b5c6ced7f8b9ac6028c37c9/html5/thumbnails/38.jpg)
Thank You
Questions?