    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    Construction Approval

    Lifting

    Devices

    Is testingrequired

    before firstuse?

    If yes, whattesting

    method?

    Re-Test Frequency andMethod (Load, NDT,Visual Inspection)

    RegulatoryCode or

    Standard

    Pad eyes

    Wall, hull, floor, beam, etcmount type pad eyes only

    (Excluding CCU Pad Eyes)

    Yes

    Proof test to 1.5times the SWL,

    visual inspectionand pre and post

    NDT by a QualifiedInspector

    Prior to each use - Visual inspectionby a qualified individual

    1 Year- visual certification by aQualified Inspector to the degreedeemed necessary by the QualifiedInspector

    5 Year - Proof load test to 1.5 times

    the SWL or rated design, visualinspection,

    5 YearNDT- performed at thediscretion of Qualified Inspector(Required if no record on fil e)

    Deficient Padeyes lockou t (LOTO)

    ASME, OSHA,AWS D1.1

    Wire Rope Slings

    and

    Stingers

    Yes

    Proof load test to 2times the SWL andvisual inspection by

    a qualifiedinspector

    Prior to each use - Visual inspectionby a qualified individual

    1 Year(from in servi ce date)Replace or conduct an annual 3rdparty proof load test to 2 times theSWL and visual inspection by aqualified inspector.

    ASME, API RP2D, OSHA, BP

    Nylon Slings / Pallet Straps

    (Synthetic Slings)

    Yes

    Proof Load testedby Manufacturer

    visual inspection by

    a qualifiedinspector

    Prior to each use - Visual inspectionby a qualified individual

    1 Year (from in service date)-Discard and replace nylon / syntheticslings.

    Heavy soiled/oiled/UV damaged/cut ortorn slings to be discardedimmediately.

    ASME, OSHA,API RP 2D, BP

    Shackles

    Yes

    Proof load test to 2times the SWL andvisual inspection by

    a qualifiedinspector

    Prior to each use - Visual inspectionby a qualified individual

    1 year - Visual recertificationinspection by a qualified inspector

    API RP 2D,ASME, OSHA, BP

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    3/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

    Spreader Bars Yes

    Proof load test to 2times the SWL,

    visual inspectionand NDT by

    qualified person.

    Prior to each use - Visual inspection

    by a qualified individual

    1 Year- visual certification by aQualified Inspector to the degreedeemed necessary by the QualifiedInspector

    5 Year Proof load test to 2 times theSWL, Visual inspection and NDT byQualified Inspector

    ASME, OSHA

    Cargo Carrying Unit (CCU)

    Portable Offshore Units

    Baskets, skids, skid mountedequipment, cabins, boxes,

    pallet types, reels and skidmounted types, tanks all types.

    ISO type lifting PointsProhibited

    NOTE: EXCLUDESPERSONNEL BASKETS

    (X-904)

    Yes

    Visual inspectionprior to each use.

    Proof Load test to 2

    times max grossweight, NDTinspection

    conducted byqualified person.

    Prior to each use - Visual inspectionby a qualified individual

    12 months Visual inspection by aQualified Inspector and NDT required

    5 Year Proof load test to 2 times theMGW (maximum gross weight), Visualinspection and NDT by QualifiedInspector

    Aft er modi fication o r repair Proofload test to 2 times the MGW(maximum gross weight), Visualinspection and NDT by QualifiedInspector

    ASME, DNV, BP

    Trolleys Yes

    Proof load test to125 % of SWL,

    visual inspectionand NDT by a

    Qualified Inspector

    Prior to each use - Visual inspectionby a qualified individual

    1 Year- visual certification by aQualified Inspector to the degree

    deemed necessary by the QualifiedInspector

    5 Year- Proof load testing to 125 % ofthe SWL, visual inspection

    NDT- performed at the discretion ofQualified Inspector

    5 Year Integrity Check- Discardolder equipment to ensureadequate safety factors aremaintained

    API RP 2D,ASME,

    OSHA,OGP

    Monorails Yes

    Proof load test to125 % of SWL,

    visual inspectionand NDT by a

    Qualified Inspector

    Prior to each use - Visual inspection

    by a qualified individual1 Year- visual certification by aQualified Inspector to the degreedeemed necessary by the QualifiedInspector

    5 Year- Proof load test to 125 % ofthe SWL, visual inspection

    NDT- performed at the discretion ofQualified Inspector

    API RP 2D,ASME, OSHA

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    4/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    Chain Fall / Hoist Yes

    Proof load test to125 % of SWL,

    visual inspectionby a Qualified

    Inspector

    Prior to each use - Visual inspection

    by a qualified individual andconsultation of operating manual forproper configuration.

    1 Year- Proof load tested to 125 % ofthe SWL and visual inspection by aQualified Inspector

    5 Year Integrity Check- Discardolder equipment to ensureadequate safety factors aremaintained

    ASME, OSHA, BP

    Eye Bolts with ThreadedRods

    No Inspected byManufacturer

    Prior to each use visual inspection byqualified person. 1 year inspecti on.

    See guide for inspection in ASMEB30.26-2.8.4

    ANSI / ASMEB30.26-2010

    Master Links, all type Ringsand Swivels

    Yes

    By Manufacturer.

    And by RiggingSupply Company

    Prior to each use - Visual inspectionby a qualified individual

    1 year inspection and tested whenattached to sling rigging set prooftested to 2 times rated load. (same asslings)

    ASME B30.26-4

    BP

    Rigging Blocks all Types NO

    Inspection byqualified person

    Prior to each use - Visual inspectionby a qualified individual

    In service date:Annual Inspectionand certification by qualified inspector.Proof tested 1.5 times rated capacity.

    Review ASME B30.26-5.8.4 forremoval from service.

    ASME B30.26-5

    BP

    Tripods & A-Frames Yes

    Proof load test to125 percent ofSWL, visual

    inspection andNDT by a Qualified

    Inspector

    Prior to each use - Visual inspectionby a qualified individual

    1 Year- visual certification by aQualified Inspector to the degreedeemed necessary by the QualifiedInspector

    5 Year- Proof load testing to 125percent of the SWL, visual inspectionand NDT by a Qualified Inspector

    ASME

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

    Note: Any lifting & rigging equipment that is found to be defective should be tagged out ofservice immediately and properly discarded or repaired.

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    5/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    PADEYE INSPECTION CRITERIA

    Inspection Criteria

    Damage

    Corrosion

    Cracks

    Bending or twisting

    Ensure there are no jagged or flame cut eyes

    Correct and legible tag information

    Most Common Causes of Damage

    Damage due to misuse1. Deformation due to overload or improper lifting

    Effects of the environment1. Severe corrosion, Pitting or metal loss, Abrasions from side loading,

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

    Holes are not with inindust ry standards. Padeye hole ID must be 6 to10% larger than the ODshackle in OD size.

    Appl icable Standards

    ASME

    OSHA AWS D1.1

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    6/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    WIREROPESLING

    INSPECTION

    CRITERIA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    7/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    NYLON SLING INSPECTION CRITERIA

    SHACKLE INSPECTION CRITERIA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    8/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    SHACKLE INSPECTION CRITERIA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    9/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    SPREADER BAR INSPECTION

    Inspection Criteria

    Damage

    Corrosion

    Smooth boreholes (pad eyes)

    Cracks

    Security of weld / bolts

    Wear

    Deformation

    Correct and legible tag information

    Most Common Causes of Damage Damage due to misuse

    2. Bent or broken pad eyes or supports3. Deformation due to overload or improper lifting

    Effects of the environment1. Severe corrosion2. Pitting or metal loss

    Appl icable Standards

    ASME

    OSHA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    10/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    CARGO CARRYING UNIT INSPECTION CRITERIA

    Appl icable Standards

    BP

    DNV 2.7-1

    ASME B30.20

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    11/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    TROLLEY BEAM INSPECTION CRITERIA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    12/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    MONORAIL INSPECTION CRITERIA

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    13/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    CHAINFALL / HOIST INSPECTION CRITERIA

    Inspection Criteria

    Damage

    Corrosion

    Cracks

    Chain condition

    Sheave or pinion wear

    Hook deformation

    Correct and legible tag information

    Most Common Causes of Damage

    Damage due to misuse1. Deformation due to overload or improper lifting

    Effects of the environment1. Severe corrosion2. Pitting or metal loss

    Appl icable Standards

    ASME

    OSHA

    BP

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012

  • 8/10/2019 Lifting Gear Inspection & Maintenance (1).pdf

    14/14

    BP GoM RPU Lif ting Gear Inspection and MaintenanceRequirementsDocument Number: CD # UPS-US-SW-GOM-HSE-DOC-00175-2

    Control Tier 2 GoM HSSE Doc owner: Jake Reidenbach - GoM Regional Lifting Technical Authority Revision Date: 06/19/201

    A-FRAME INSPECTION CRITERIA

    Inspection Criteria

    Damage

    Corrosion

    Cracks

    Sheave or pinion wear

    Loose or missing bolts, nuts or rivets

    Operation of limiting devices (if installed)

    Correct and legible tag information

    Most Common Causes of Damage

    Damage due to misuse1. Deformation due to overload or improper lifting

    Effects of the environment1. Severe corrosion2. Pitting or metal loss

    Appl icable Standards

    ASME

    Uncontrolled Document. Valid Only at the Time of Printing. Print Date: 10/31/2012