![Page 1: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/1.jpg)
www.SensidyneGasDetection.com
![Page 2: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/2.jpg)
Detection at every point.
2
Safety is not a convenience. Sensidyne proudly designs, manufactures, and distributes gas monitoring systems relied upon by customers for detection of gas in critical safety applications for personnel safety and asset protection. Our customers know us by our quality products and commitment to service. We understand that our quality equals customer safety and productivity.
Quality assured. Sensidyne is committed to providing products and services that consistently meet customer needs and comply with applicable statutory and regulatory requirements. Our Quality Management System is structured in accordance with ISO 9001:2008, and as such, we strive to ensure continuous improvement through ongoing review of our designs, supplier performance, and customer feedback.
Sensidyne employees share the responsibility to provide products that are produced with the highest level of quality and represent the best value and service to our customers. We are committed to meeting or exceeding customer expectations in everything we do.
Sensidyne Corporate Offices and Manufacturing Facility in St. Petersburg, Florida U.S.A.
![Page 3: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/3.jpg)
3
Manufacturing include Chemicals & Solvents, Pharmaceuticals, and Building Materials
Ammonia for Fertilizer and Refrigeration Applications
Waste Water Collection and Treatment Facilities, Wet Wells, and Pumping Stations
Oil Refining, Processing, Transportation, and Distribution
Power Generation, Battery Rooms, Boilers, and Cooling Systems
Trusted Supplier of Gas Detection to a Wide Range of Industries & Applications
And many more common and specialty applications.
Breweries, Food & Beverage, Paper, Flavors & Fragrances, and
Research Laboratories
![Page 4: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/4.jpg)
Detection at every point.
4
Advanced Safety Integrity for confidence in every safety application.
Industry-leading reliability, SensAlert ASI is the ideal fixed-point gas detector for critical safety applications. Flexible configurations and a simple interface provide maximum application versatility while remaining the easiest to install, commission, operate, and maintain.
SensAlert ASI is third-party certified to IEC61508 Level 2 (SIL-2) for both hardware and software. SIL certification is assurance that the product received independent testing validation. Sensor performance response verification is available through the Test-on-Demand feature. Predictive Sensor End-of-Life Indication provides advanced warning of impending sensor failure. Combined, these features ensure the greatest up-time without increasing maintenance tasks or costs.
SensAlert ASI is a universal instrument platform for toxic & combustible gas detection and oxygen monitoring; its design provides standardized installation across a complete plant or facility.
SensAlert ASI provides unmatched application versatility through remote sensors and gassing, duct mount, and sample-draw to maximize application versatility.
SensAlert ASI is engineered to overcome the challenges users face with traditional gas detectors. The universal instrument platform for all gas and sensor types provides common installation for each detection point with vertical or horizontal installation options and removable plug-type terminal blocks to simplify wiring and commissioning.
Critical Protection with Global Approval Unmatched Application VersatilityEasiest to Install, Commission, Operate, and Maintain
¡ Functional Safety, unquestionable reliabilityThird-party SIL-2 certification validating long-term reliability Sensors are performance tested and certified providing assured capability Sensor Test-On-Demand, with on-board gas generator
¡ Universal platform with Intrinsically Safe sensor headReplace sensors without area declassification or work permitsShop calibrate then hot-swap gas sensors in classified areas Remote mount sensor up to 100 ft./30 m. away without rigid conduitModbus, HART, and 4-20 mA communication options
¡ Intelligent Plus Series sensorsAuto-recognition and set-up from sensor memory Extensive sensor range for Flammables/Combustibles, Toxics, and OxygenCompatible with all Plus Series sensor ranges and technologies
¡ Flexible installation or retrofit2-wire and 3-wire transmitter models with global performance approvals Unrestricted installation and operation in hazardous classified areasNon-intrusive configuration and maintenance Interface Configurable alarms & warnings for hazard mitigation and notification
![Page 5: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/5.jpg)
5
Technical SpecificationsSensors Gas Sensors: ...Electrochemical, Infrared, Catalytic Bead Test-On-Demand Modules: ....................Type C and Type S
ElectricalVoltage 2-Wire 24 VDC (18-30 VDC): ............................................ 20 mA 3-Wire 24 VDC (12-30 VDC): ........................................... 90 mA W/ Relay Card and combustible sensors: ..............300 mA Output and load resistance with 24 VDC at transmitter
terminals: 3 wire 4-20 mA: .............................................. 600 Ω maximum 2-wire 4-20 mA: ............................................. 350 Ω maximum Relay: ........... 3-Wire Only - One SPDT Configurable Relay Optional Card: ............ Three (3) SPDT Configurable Relays Contact Ratings: ...................5 Amps at 115 VAC or 30 VDC
Resistive Communication Options .................4-20 mA, non-isolated
2 or 4-wire, RS-485 (Modbus), HART
Controls and Display User Interface: ........................... Non-intrusive, menu driven Security: ..................................................... Password protection LEDs: .. Four (4) Red, corresponding to magnetic keypad,
and Alarm Relays when equipped. Graphic LCD: ....................128 by 64 pixel screen (backlight
on 3-wire transmitters); displays Concentration and Measuring Units, Gas Name or Type, Sensor Span, Date and Time, Tag Number, System messages or
Warnings, and Calibration Due notification
Environmental Temp. (Transmitter): ............ -20°F to 158°F /-29°C to 70°C Humidity (Transmitter)...........0-90% RH, non-condensing Temp. (Sensor): ..................................See Sensor Data Sheets Humidity (Sensor): ............................See Sensor Data Sheets Moisture Resistance ..IP54; IP56 with optional rainshield
Enclosure Standard: .........................Blue, Copper-free Cast Aluminum Dimensions: ................................. 6.7” W x 12.2” H x 6.5” D
170 mm W x 308 mm H x 165 mm D Weight Range: .......................................................................6-8 lbs
2.7-3.6 kg Long-dome ................... Gray, Copper-free Cast Aluminum Physical: ....................................... 6.3” W x 11.7” H x 7.1” D
160 mm W x 297 mm H x 180 mm D Weight Range: ....................................7-8.7 lbs / 3.2-4.0 kg
Approval Ratings Explosion Proof ...........................NEC and CEC Class I Div 1,
Grps A, B, C, D; Class II Grps E, F, G; Class III T4 Flame proof ............................. ATEX EEx d[ia] IIC T4 II 2 [1] G Non-Incendive ..............................NEC and CEC Class I Div 2,
(Enclosed Break) .. Groups A, B, C, D; Class II Grps E, F, G; Class III T4
ATEX EEx nC [ia] IIC T4 II 3 [1] G Intrinsic Safety .............................NEC and CEC Class I Div 1,
Grps A, B, C, D;Class II Grps E, F, G; Class III T4
ATEX EEx ia IIC T4 II 1 G FM Approved / CE Mark ...................ATEX Directive 94/9/EC IECEx .........................................Zone 0: Display Ex d [ia] IIC T4
Sensor Ex ia IIC T4; Zone 1: Ex d [ai] IIC T4; Zone 2: EXnC [ia] IIC T4
UL / IEC................... IEC 60079-0:2006, IEC 60079-11:1999, IEC 60079-15:2007
SIL-2 Certified ..IEC 61508 SIL-2 Parts 1,2, & 3 Hardware & Software. Fit for use in SIL-2 applications.
See approval drawings and sensor specification sheets for additional detail.
Main Display Main Menu
Sensor Data Review System Configuration Menu
Predictive Sensor Life Live Test-on-Demand Sensor Verification
Description Horizontal VerticalSensAlert ASI Div 2, 2 wire | 3/4” NPT S22-2STH-AA S22-2STV-AA
SensAlert ASI Div 2, 3 wire | 3/4” NPT S22-3STH-AA S22-3STV-AA
SensAlert ASI Div 2, 3 wire with relay card | 3/4” NPT S22-3RTH-AA S22-3RTV-AA
SensAlert ASI Div 2, 3 wire with Modbus | 3/4” NPT S22-3MTH-AA S22-3MTV-AA
SensAlert ASI Div 2, 3 wire with Hart | 3/4” NPT S22-3HTH-AA S22-3VTV-AA
SensAlert ASI Intrinsically Safe, 3 wire | 3/4” NPT S2S-3STH-AA S2S-3STV-AA
SensAlert ASI Div 1, 2 wire | 3/4” NPT S2X-2STH-AA S2X-2STV-AA
SensAlert ASI Div 1, 3 wire | 3/4” NPT S2X-3STH-AA S2X-3STV-AA
SensAlert ASI Div 1, 3 wire with relay card | 3/4” NPT S2X-3RTH-AA S2X-3RTV-AA
SensAlert ASI Div 1, 3 wire with Modbus | 3/4” NPT S2X-3MTH-AA S2X-3MTV-AA
SensAlert ASI Div 1, 3 wire with Hart | 3/4” NPT S2X-3HTH-AA S2X-3HTV-AA
Available with 3/4” NPT or 25mm openings. See the Sensor Chart on page 18 for available gases and ranges.
SensAlert ASI Graphic Display and Menu
Embracing Intrinsic Safety for the ROI
Intrinsic Safety (I.S.) is a method of electrical protection for safe operation of electrical equipment in hazardous (classified) areas by limiting the energy available for ignition. I.S. installation provides many cost saving advantages as it does not require expensive rigid conduit or a hot work permit for instrument maintenance. I.S. installation should be considered when existing wiring does not meet code requirements or for new installations where cable trays will be employed using power limited tray cable. Consult the Application Engineering Team at Sensidyne to discuss if I.S. is right your application.
I.S.
![Page 6: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/6.jpg)
Detection at every point.
6
Universal platform gas detection transmitter for safety applications.
SensAlert Plus is a reliable gas detector for personnel safety applications and represents the evolution of smart sensor technology. As a universal platform, it accepts Infrared, Catalytic Bead, and Electrochemical sensors for detection of a wide range of gases.
Intelligent and dependable firmware monitors the intelligent Plus sensor for changes that could effect performance. Sensor condition and maintenance notifications are displayed locally and can be sent to a controller or facility monitoring system via on-board relays, a virtual relay (assignable to a fault current), RS-485 Modbus, or HART. This thorough monitoring provides increased reliability.
The SensAlert Plus Intrinsically Safe sensor head can be remote mounted up to 100 feet (30m) from the transmitter providing greater flexibility to position the transmitter in an personnel-accessible location while positioning the sensor closer to potential hazards. A wide range of sensors, accessories and remote gassing/sampling systems further simplify maintenance and provide installation flexibility.
Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration time. A large backlit alphanumeric display with a non-intrusive user interface allows for configuration, setup, and data review without declassifying a hazardous area. SensAlert Plus is a universal transmitter allowing facility standardization across gas types, sensor technologies, and sensor ranges.
Increased Reliability Simple to Intall and Maintain Reduced Cost of Ownership
¡ Reliability with advanced functionalityPredictive Sensor End-of-Life Indication Missing or Non-functional Sensor Indication Sensor Test-On-Demand, with On-board Gas Generator
¡ Intrinsically safe sensor headShop Calibrate and Hot-swap Gas Sensors in Classified Areas Mount Sensor up to 100 ft./30 m. Away Without Rigid Conduit
¡ Intelligent Plus Series sensorsAuto-recognition and Set-up from Sensor Memory ProvidesOperating Parameters and Diagnostics for All Plus Transmitters
¡ Global performance approvalsPerformance Tested and Certified to FM, ATEX, and CSA Standards Unrestricted Hazardous Classified Area Installation and Operation
¡ Flexible installation or retrofit2-Wire and 3-Wire Transmitters with Enclosure Options Non-intrusive Configuration and Maintenance Interface Remote Sensor / Gassing, Duct Mount and Sample Draw Configurable Alarms: Fault Conditions and Test-on-Demand
![Page 7: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/7.jpg)
7
Technical SpecificationsSensors Gas Sensors: ...Electrochemical, Infrared, Catalytic Bead Test-On-Demand Modules: ....................Type C and Type S
ElectricalVoltage 2-Wire 24 VDC (18-30 VDC): ............................................ 20 mA 3-Wire 24 VDC (12-30 VDC): ........................................... 90 mA With opt. Relay Card and combustible sensors: .300 mA Output and load resistance with 24 VDC at transmitter
terminals: 3 wire 4-20 mA: .............................................. 600 Ω maximum 2-wire 4-20 mA: ............................................. 350 Ω maximum Relay: ........... 3-Wire Only - One SPDT Configurable Relay Optional Card: ............ Three (3) SPDT Configurable Relays Contact Ratings: ...................5 Amps at 115 VAC or 30 VDC
Resistive Communication Options .................4-20 mA, non-isolated
2 or 4-wire options, RS-485 (Modbus), HART
Controls and Display User Interface: ........................... Non-intrusive, menu driven Security: ..................................................... Password protection LEDs: .. Four (4) Red, corresponding to magnetic keypad,
and Alarm Relays when equipped. Graphic LCD: ....................128 by 64 pixel screen (backlight
on 3-wire transmitters); displays Concentration and Measuring Units, Gas Name or Type, Sensor Span, Date and Time, Tag Number and System messages or Warnings
Environmental Temp. (Transmitter): ............ -22°F to 158°F /-29°C to 70°C Humidity (Transmitter)...........0-90% RH, non-condensing Temp. (Sensor): ..................................See Sensor Data Sheets Humidity (Sensor): ............................See Sensor Data Sheets Moisture Resistance ..IP54; IP56 with optional rainshield
Enclosure NEMA 4X:.................................................................Polycarbonate Dimensions: ............................7.5” W x 12.6” H x 6.2” D /
190 mm W x 320 mm H x 157 mm D Weight Range: ................................ 5.5-7.2 lbs / 2.5-3.3 kg Explosion-proof .......................Copper-free, Cast Aluminum Physical: ........................ 5.5” W x 12.3” H x 4.6” [6.4”] D /
140 mm W x 312 mm H x 117 mm [163 mm] D Weight Range: ................................ 6.1-8.7 lbs / 2.8-4.0 kg Note: Brackets indicate large dome depth.
Approval Ratings Explosion Proof ...........................NEC and CEC Class I Div 1,
Grps A, B, C, D; Class II Grps E, F, G; Class III T4 Flame proof ............................. ATEX EEx d[ia] IIC T4 II 2 [1] G Non-Incendive ..............................NEC and CEC Class I Div 2,
(Enclosed Break) Grps A, B, C, D; Class II Grps E, F, G; Class III T4
ATEX ...................................................EEx nC [ia] IIC T4 II 3 [1] G Intrinsic Safety ....NEC | CEC Class I Div 1, Grps A, B, C, D;
Class II Grps E, F, G; Class III T4 ATEX ...................................................................EEx ia IIC T4 II 1 G CE Mark ...................................................ATEX Directive 94/9/EC FM Approved IEC 60079-0:2006, IEC 60079-11:1999,
IEC 60079-15:2007See approval drawings and sensor specification sheets for
additional detail.
Main Display Main Menu
Data Review System Configuration Menu
Test-on-Demand Data ReviewCalibration Review
Description Part NumberSensAlert Plus Div 2, 2 wire 820-0209-01
SensAlert Plus Div 2, 3 wire 820-0204-01
SensAlert Plus Div 2, 3 wire with relay card 820-0204-02 with 821-0219-01
SensAlert Plus Div 2, 3 wire with Modbus 820-0204-02 with 821-0221-01
SensAlert Plus Div 2, 3 wire with Hart 820-0204-02 with 821-0220-01
SensAlert Plus Intrinsically Safe, 3 wire 820-0204-04
SensAlert Plus Div 1, 2 wire 820-0207-01
SensAlert Plus Div 1, 3 wire 820-0206-01
SensAlert Plus Div 1, 3 wire with relay card 820-0206-02 with 821-0219-01
SensAlert Plus Div 1, 3 wire with Modbus 820-0206-02 with 821-0221-01
SensAlert Plus Div 1, 3 wire with Hart 820-0206-02 WITH 821-0220-01
SensAlert Plus Graphic Display and Menu
FM Performance Certified Sensors
The Sensidyne Sensor Laboratory is a Factory Mutual (FM) certified facility. The laboratory is certified for sensor development and testing. The majority of Plus Series sensors are FM performance certified. This certification provides verification that sensors have undergone rigorous testing for accuracy, response time and environmental conditions. Each Plus Series sensor datasheet contains complete response characteristics, calibration instructions, and a cross interference table to assist user implementation of their monitoring applications
![Page 8: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/8.jpg)
Detection at every point.
8
Advanced all-in-one gas detection system for local and remote gas detection.
SensAlarm Plus is a complete single point gas detection system including a transmitter, power supply, outputs, and annunciation. It is extremely cost-effective and easy to install. SensAlarm Plus accepts all Plus Series sensors making it appropriate for a wide range of applications.
SensAlarm Plus is a complete gas detection system in one enclosure. The system is fully equipped with strobe, horn, high-visibility four-digit LED Display and LCD Display / Interface. At the core of SensAlarm Plus is an advanced Intelligent Sensor platform with non-volatile memory for all key application variables and sensor data. A non-intrusive user interface enables operational customization and access to sensor life parameters, TWA alarms, calibration data and other information with date and time recording.
The SensAlarm Plus sensor head is universal in that it accepts all Sensidyne Plus sensors. Monitoring in high, low or adjacent locations is simplified by remote mounting the sensor head using 4 conductor cable. The automatic uploading of variables, alarm values and sensor information when a sensor is plugged in greatly simplifies installation and maintenance. Transportable calibration allows sensor calibration at the point of installation or in a workshop, then hot-swapping the sensor in the field.
SensAlarm Plus is the ideal gas monitoring solution for labs, gas cylinder storage, industrial work areas, control room protection or any other applications where users benefit from a packaged gas detection system that works with all SensAlert Plus sensors.
Exceptional Capability Easy to Use and Maintain Application-friendly Design
¡ Complete gas detection systemStand-alone single point gas detection system1 or 2 double-flash strobes, horn and resetOptional battery back-up
¡ Intelligent Plus Series sensors for Combustible and Toxic gases Oxygen enrichment & deficiencyPercent remaining sensor lifeSensor auto-recognition and configurationUploads application parameters and gas & alarm dataTime-stamped event and calibration data
¡ Application-flexible installation and easy maintenanceNon-intrusive configuration and maintenance interfaceRemote sensor & gassing, duct mount, or sample drawMount sensor up to 100 ft./30 m. away using 4 conductor cable
Shown with optional second strobe.
![Page 9: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/9.jpg)
9
Technical Specifications
Sensors Gas Sensors: ...Electrochemical, Infrared, Catalytic Bead Test-On-Demand Modules: ....................Type C and Type S
Electrical Design ..................................................... Microprocessor based
with nonvolatile memory. Automatically resumes operation after power failure.
Power ........................100-240 VAC, 50/60 Hz or 20-30 VDC. Battery .........................Optional battery back-up available Outputs ............................................... 4-20 mA into 600 ohms;
Optional RS-485, Modbus RTU Protocol, Strobe .....................................Red lens flashing strobe (NEMA
4X) standard with optional dual strobes with red and amber strobe.
Horn ..................................................................... 95 dB piezo horn Alarm Relays ......................................................SPDT, 6 Amps @
120VAC or 24VDC, User accessible SPDT Fault, Low & High Alarm Relays. Additional relays for Strobe & Sounder. Note: Alarm values stored in non-volatile memory.
Controls and Display LCD Display................. Alphanumeric (Value, Gas, & Units). LED Display .............4 Digit x 1.5 Inch Tall Red LED (Value). Indicators ..........Power source LEDs (AC, DC and Battery),
Alarm and corresponding to magnetic keypad LEDs Security ............ Password Protected Configuration Menu Auto Config. ....................System automatically senses the
presence of optional modules and features Reset/silence .....................External push button switch for
acknowledge (Alarm sequence 3A) Annunciators.........Audible (+95db) & Visual single strobe
with optional second strobe
Environmental Temp. ...............................................-4° to 122°F (-20° to 50°C). Humidity .....................................0-90 %RH, non-condensing. Location ............................................................Indoor or Outdoor Temp. (Sensor): ..................................See Sensor Data Sheets Humidity (Sensor): ............................See Sensor Data Sheets
Enclosure Material............................................................................ Fiberglass. Description .......................................UL listed, NEMA 4X Rated Type................... Wall mount with tabs & threaded inserts. Overall Size ...............9.75 (W) by 20 (H) by 6.4 (D) Inches, /
24.8 (W) by 50.8 (H) by 16.3 (D) cm. Weight ..... 9.75 - 13.75 lbs. (4.4 - 6.3 Kg) including sensor Conduit .................3/4 inch EMT connector supplied (side). Sensor Head .........................................................................................
Sensor head enclosure and retaining ring are black anodized aluminum; splash guard, and most other accessories are made of PVC.
See approval drawings and sensor specification sheets for additional detail.
Description Part NumberSensAlarm Plus, one red strobe, integral or remote sensor option 820-0301-01
SensAlarm Plus, one strobe w/ battery back-up 820-0301-02
SensAlarm Plus, two strobes, integral or remote sensor option 820-0301-03
SensAlarm Plus, two strobes w/ battery back-up 820-0301-04
SensAlarm Plus remote sensor kit (100ft maximum) 821-0301-01
HART Communication Card - Installed 821-0302-01
RS-485 Modbus RTU Communication Card - Installed 821-0303-01
Duct Mount
Remote Mount
SensAlarm Plus used in a laboratory setting
SensAlarm Plus with remote kit for monitoring a gas storage room
Common SensAlarm Plus Applications
SensAlarm Plus is an excellent single-point gas detection solution for a wide range of applications. The flexibility of the Plus Series instruments are extended even further through remote mount and duct mount sensors. These options allow users to place the sensor closer to potential leak sources for rapid detection of gas.
Application Flexibility
![Page 10: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/10.jpg)
Detection at every point.
10
Cost effective, heavy duty gas detector with enhanced poison resistance.
SensAir CMB is a heavy duty combustible gas detector with a highly poison resistant catalytic bead sensor. Its cost effective, Division 1 hazardous area approvals, and highly visible LED display make SensAir CMB the ultimate solution for OEM and high-volume applications.
SensAir CMB is a heavy duty combustible point gas detector employing a sensor designed with enhanced poison resistance to Sulfides and Silicon. This advanced sensor technology in SensAir CMB significantly reduces the effects of poisoning, thereby minimizing the replacement of sensors and costs of ownership, making this product a cost effective, robust gas detector for chemical and hydrocarbon processing and manufacturing facilities.
The SensAir CMB catalytic bead sensor employs carefully matched pellistors (catalytic beads) that provide uniform electrical resistance over temperature. The active pellistor oxidizes the combustible gas when present while the reference pellistor enables compensation for changes in ambient conditions. Comparing the pellistors provides an output proportional to gas presence, providing excellent gas sensitivity, rapid response, and extended sensor life.
SensAir CMB is housed in a rugged explosion-proof cast aluminum enclosure with horizontal or vertical conduit orientation. The bright LED display and non-intrusive user interface means fast set-up and maintenance. A 316 stainless steel sensor housing provides excellent corrosion resistance. 3-Wire, 4-20mA output completes the product.
Poison Resistant Sensor High-powered Cat-Bead Sensor Reduced Cost of Ownership
¡ Division 1 & Division 2 and ATEX Zone 1 & Zone 2 approved
¡ Explosion proof 316 stainless steel sensor housing
¡ Poison resistant catalytic bead sensor with rapid response
¡ Highly visible bright LED display
¡ Non-intrusive zero and span adjustments
¡ 3-wire design with 4-20mA output
¡ Horizontal or vertical installation options
![Page 11: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/11.jpg)
11
Technical SpecificationsSensor Poison resistant catalytic bead. SensAir CMB can be
used for detection of Methane, Propane, Pentane, Butane and most other common combustible gas detection needs.
Electrical Power Requirement ........ 24 VDC, nominal, up to 6 Watts Voltage Range .............................................................. 12-30 VDC Current Consumption (Max) .........300mA, typical 125mA Termination Resistance ................................Less than 500Ω
250Ω recommended Transmission Link ......................... 4–20 mA current source,
non-isolated with respect to Common (3 wires)
Controls and Display User Interface: ........................................................ Non-intrusive Security: ..................................................... Password protection LEDs: ...... SIX (6) Red, corresponding to magnetic keypad LED Display: ........................... Seven segment, displays gas
concentration
Environmental Operating Temperature ............-4˚ to 167˚F (-20˚ to 75˚C) Storage Temperature .............-40˚ to 122˚F (-40˚ to 50˚C) Operating Humidity ................0-95% RH, non-condensing Oxygen Requirement .............. 10% by volume, minimum
Enclosure Transmitter: ...................................................Painted Aluminum Dimensions: ......................... 5.7” W x 6.46” H x 5.03” D /
145 mm W x 164 mm H x 127 mm D Sensor Housing ............................................316 Stainless Steel
Approval Ratings FM US and Canadian | NEC/CEC
Class I, Div 1, Groups A, B, C, D T4; Nonincendive for installation in Class 1 Division 2 Groups A, B, C, D (FM6320, C22.2 No. 152)
ATEX CE 0518 II 2 G Ex d IIC T4 (FM13ATEX0066) II 3 G Ex nA d IIC T4 (FM13ATEX0084)
See approval drawings and sensor specification sheets for additional detail.Description Part Number
SensAir CMB with Methane 0-100%LEL sensor, horizontal config., Div. 1 Approved 820-0610-01
SensAir CMB with Propane 0-100%LEL sensor, horizontal config., Div. 1 Approved 820-0610-02
SensAir CMB with K-Factor 0-100%LEL sensor, horizontal config., Div. 1 Approved 820-0610-03
SensAir CMB with Methane 0-100%LEL sensor, vertical config., Div. 1 Approved 820-0611-01
SensAir CMB with Propane 0-100%LEL sensor, vertical config., Div. 1 Approved 820-0611-02
SensAir CMB with K-Factor 0-100%LEL sensor, vertical config., Div. 1 Approved 820-0611-03
SensAir CMB with Methane 0-100%LEL sensor, horizontal config., Div. 2 Approved 820-0620-01
SensAir CMB with Propane 0-100%LEL sensor, horizontal config., Div. 2 Approved 820-0620-02
SensAir CMB with K-Factor 0-100%LEL sensor, horizontal config., Div. 2 Approved 820-0620-03
SensAir CMB with Methane 0-100%LEL sensor, vertical config., Div. 2 Approved 820-0621-01
SensAir CMB with Propane 0-100%LEL sensor, vertical config., Div. 2 Approved 820-0621-02
SensAir CMB with K-Factor 0-100%LEL sensor, vertical config., Div. 2 Approved 820-0621-03
SensAir CMB Accessories
Calibration Adapter (821-0604-01)
Also available in a “blind” version. Hand-held Controller for use with blind version.
Poison Resistant Catalytic Bead Sensor
Industrial atmospheres often contain catalyst poisons such as silicon, silane, lead, sulfur, or phosphorous compounds. These catalysts are known to poison low-powered catalytic bead sensors. Silicon compound concentrations of less than one part per million (ppm) will quickly degrade the performance of a standard catalytic bead sensor and render it ineffective at sensing the presence of combustible gases. The Sensidyne high-powered Cat-Bead sensor used in SensAir CMB is a proven proprietary poison resistant sensor, minimizing these problems and extending sensor life.
PR
Flow Block (821-0605-01)
Sensor Shield (821-0603-01)
![Page 12: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/12.jpg)
Detection at every point.
12
Added visual and audible annunciation warning workers and supervisors.
Sensidyne Alarm Annunciators provide audible and visual warning of gas hazard alarms to nearby workers and supervisors - alerting them to follow alarm procedures or not to enter the area.
Description Part NumberClass 1, Division 2, 123-230 VAC Strobe only for mounting by user – Red 208-0003-04
Alarm Annunciator, Dual Strobes, High Red, Low Amber, includes power supply 821-0005-02
Alarm Annunciator, Dual Strobes and Sounder, including power supply 821-0005-03
Alarm Annunciator, Hi Red, Hi Sounder, including power supply 821-0005-04
Alarm Annunciator, Hi Red, Hi Sounder, no power supply 821-0005-08
Alarm Annunciator, Hi Sounder, Low Amber strobe, includes power supply 821-0005-01
4-Port Power Module, 10 watt, 24 VDC (85-265 VAC) 7013949-4
2-Port Power Module, 10 watt, 24 VDC (85-265 VAC) 7013949-2
Red GP Strobe Lamp for mounting by user 12-48 VDC, general purpose 7017414
Amber GP Strobe Lamp for mounting by user 12-48 VDC, general purpose 208-0002-02
Blue GP Strobe Lamp for mounting by user 12-48 VDC, general purpose 208-0002-06
GP 110 dB Horn for mounting by user 9-28 VDC, general purpose 7017380
Annunciators can be connected to any Sensidyne gas detection transmitter or system for local visual or audible alarm annunciation. Annunciators can power a transmitter and become a mini-system using alarm contacts in the transmitter. The Annunciators have a universal power supply, or can be powered externally to preserve operation in the event of a power failure. A bright green power light is often wired through system fault contacts to also indicate “system ready,” that is operational. Sensidyne application personnel can assist you with gas detection alarm sequences, annunciation and truth table preparation.
Condition Communication
¡ Single and dual strobe options
¡ Power supply option to power transmitters
¡ General purpose or hazardous area approved models
¡ Options for stand-alone components or as part of a package
Local Alarm Annunciators
![Page 13: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/13.jpg)
13
Approved solution for monitoring gas in remote or difficult to access applications.
Sensidyne Sample Draw is the only FM listed system approved for remote sampling in Class 1 Division 2 areas from Class 1 Division 1 areas. This system is a flexible solution for complex gas detection applications in remote and difficult to access locations.
Description Part NumberPumped Sample Draw with 24 VDC power supply 821-0231-01
Aspirated Sample Draw with 24 VDC power supply 821-0232-01
Pumped Sample Draw without power supply 821-0231-02
Aspirated Sample Draw without power supply 821-0232-02
Coalescing filter & Close Nipple 1/8 NPT 821-0233-01
Installer to provide 24 VDC power when ordering 821-0231-02.
Technical SpecificationsElectricalPower In/Out: .........................85–264 VAC, 47-63 Hz, 1.2 Amps;
24 VDC, 1.1 Amp max.
Controls and Display External: ..........................Flowmeter, green power LED and
red fault/low flow LED Internal: ........................... On-Off switch, voltage out adjust
and flow rate adjust Outputs: ...................................Two 24 VDC power terminals,
SPDT fault/low flow relay contact
Environmental Temperature:..................................-4° to 104°F (-20° to 40°C) Humidity: ..............5-95% RH, non-condensing for indoor
or outdoor locations.
Enclosure Material.............NEMA 3R Fiberglass wall mount with two
3/4” conduit entries Dimensions: ................................11” (H) X 10” (W) X 6.375” (D)
(27.9cm X 25.4cm X 16.2cm) Weight: .......................................................................6.6 lbs (3.0 kg)
Approval Ratings Hazloc ........... FM approved for Class I, Division 2, Groups
C & D location to sample from Class I, Division 1, Groups C & D;
DC Supply: ............................. UL60950-1, UL508, UL1310(3), EN60950-1, CE Mark
Pump:........................... Diaphragm type rated at 1.0 LPM @ 40” H2O at pressurized leak rate of < 1.0 inch wc drop in 5 seconds at 25 inches wc
Wetted parts: ................. Polycarbonate, Neoprene, Tygon 2075, Silicone Silastic, 304/316ss, Buna-N, Brass, PVC, Glass, Acrylic and User Tubing
See approval drawings and specification sheets for additional detail.
Best safety practices aim to minimize personnel time working in hazardous (classified) areas. The Sensidyne Sample Draw System pulls air from hazardous locations to pass through a flow block(s) attached to gas detection sensor(s). It’s offered with a diaphragm pump or an air operated aspirator. The system meets requirements for installation according to common fire and electric code.
Flow rate is easily adjustable to meet the application requirements. A flow switch wired to a fail-safe relay provides a contact on loss of flow or power. The two-way valve enables calibration and routine maintenance. The system power supply is capable of operating the pump and multiple transmitters and thus can be a stand-alone system with the addition of annunciation.
Stay out of Hazardous Areas
¡ FM listed for NFPA 820 compliance
¡ Pumped or air aspirated versions
¡ Flow sensor with relay that fails safe
¡ Internal power switch and flow adjustment
¡ External flow indication and LED’s
¡ 24 VDC power source for gas detectors
Sample Draw System
AC or DC PowerAlarm Contacts4-20 mA, RS-485
24VDC
Outdoor Vent Gas Inlet(for Calibration)
Flow DirectionSwitch
CoalescingFilter/Drain
![Page 14: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/14.jpg)
Detection at every point.
14
Four channel controller with smart features for SensAlert family transmitters.
SensAlert 4-Channel Controller is the ultimate companion for SensAlert family gas detection transmitters. With auto configuration for most sensor types and ranges, it expedites commissioning and setup.
Description Part NumberSensAlert 4-Channel Controller 7013227-3
SensAlert 4-Channel Controller with Red Strobe 7013227-4
SensAlert 4-Channel Controller with Dual Strobe Call Factory
SensAlert 4-Channel Controller for Use with SensAir 7013227-5
The SensAlert 4-Channel controller powers and monitors up to 4 channels of gas detection. With three alarm relays per channel plus a common fault relay, the controller provides local or remote alarm annunciation via the optional strobe and standard 90 dB buzzer. The controller has a latched alarm reset button and discrete LED value displays
plus LCD displays for gas name or type and value. Discrete 4-20 mA and RS-485 Modbus RTU outputs are standard. Most SensAlert and SensAlert Plus transmitters, when used with this controller, will automatically configure the controller to display the gas type, range and factory default alarms making system set up quick and easy (see page .
Easiest Controller to Use
¡ Automatic sensor configuration for many Plus Series sensors
¡ 24 VDC power source for up to four gas detectors
¡ NEMA 4X fiberglass wall-mount enclosure
¡ Easy push-button interface for fast setup
¡ Single, dual, or non- strobe options
SensAlert 4-Channel Controller
Technical SpecificationsElectrical Power ...................................85-264 VAC, 50/60 Hz or 24 VDC Check Points ........Provides reading of output current (as
40–200 mV) without breaking loop Input .................................Four 4-20 mA (2 or 3-wire signals).
Can use Sensidyne I.S. Barrier. Outputs ...................................Discrete non-isolated 4-20 mA
(600 ohm load), and 2-wire RS485 Modbus RTU
Controls and Display LCD Display..............................................Backlit Alphanumeric LED Display ............................ 3 Digit x 0.5 Inch Tall Red LED Controls ......... Internal push-button programming for all
variables with security capability. Reset button for alarms and calibration mode
Environmental Temperature .................................... 32° to 113°F (0° to 45°C) Humidity .....................................5-95 %RH, non-condensing Enclosure Material.......Fiberglass, lockable, and wall mounted with
3/4 inch EMT openings Dimensions .....................................11.2” W x 12.8” H x 6.3” D
28.4 W x 32.5 H x 16.0 D cm. Weight .................................................................. 10.0 lbs. (4.5 Kg)
Approval Ratings UL Listed NEMA 4X Enclosure
See specification sheet for additional detail and page 18 for sensor compatibility.
![Page 15: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/15.jpg)
15
Two or four channel control panel for display and management of inputs.
The model 9000 is designed to simplify management of two or four channels of gas detection transmitter inputs. Optional internal relays allow signal or startup for hazard mitigation and alarm acknowledgment.
¡ CSA approved for Class I, Div 2
¡ Graphic backlit LCD display
¡ Discrete alarm relays
¡ Accepts two or four 4-20 mA inputs
¡ RS-485 Modbus RTU output
Model 9000 Dual & Quad
Eight or sixteen channel control panel for display and management of inputs.
The Model 7100 provides management and connection of up to sixteen channels of gas detection from transmitter input. With common alarm and horn relays, it allows for easy management of multiple gas detectors. The LCD display provides simultaneous reading of gas levels.
¡ CSA approved for Class I, Div 2
¡ Accepts 8 or 16 4-20 mA inputs
¡ Graphic backlit LCD display
¡ Optional discrete alarm relays
¡ Common alarm (3) & horn (1) relays
¡ Dual (Master and Slave) RS-485 Modbus RTU outputs
Model 7100 Eight or Sixteen Channel
Description Part NumberModel 9000 Dual Two Channel with Piezo and Strobe 820-0105-04
Model 9000 Quad Four Channel with Piezo and Strobe 820-0103-04
Description Part NumberModel 7100 NEMA 4X Controller 7013931-1
8-Channel, 4-20mA Analog Input Board 7017437
Alarm Relay Card, 8 SPDT 7017524
Power Supply, 24 VDC, 150 watt 7013227-4
![Page 16: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/16.jpg)
Detection at every point.
16
Sensor Calibration & Exchange Program
This program schedules delivery of factory calibrated sensors to the Customer’s plant or facility. This service maximizes the benefit of the smart sensor Transportable Calibration feature by exchanging your combustible and toxic SensAlert or SensAlert Plus series sensors with calibrated sensors ready for installation.
Customer’s sensors are stored in our climate-controlled storage facility until the next scheduled calibration interval. Prior to shipment, the calibrated sensors are tested in our Factory Mutual (FM) approved lab, calibrated, securely packaged, and shipped along with the calibration certificate back to the Customer. Upon receipt of the calibrated sensors, the Customer removes the sensor from its packaging and installs the sensor into the transmitter. Old sensors are placed into the plastic sensor container and returned to Sensidyne for storage and the next calibration cycle. The ultimate use of Transportable Calibration.
Contact the Sensidyne Service Team at 800-451-9444 / +1 727-530-3602 x 783 or [email protected].
Start-up and Commissioning Service
Start-up of equipment, functional testing, initial calibration and training of local personnel. An expert Sensidyne Service team member visits the site to aid customers in the initial start-up of their installed gas detection equipment.
Contracted On-site Calibration or Maintenance Service
Routine calibration and other maintenance services are available to new and existing customers on an annual basis at reduced service rates.
Factory Repair Service
Sensidyne will evaluate and quote equipment repair cost for all products manufactured by Sensidyne. An RMA number is required prior to product being returned to Sensidyne.
Ensure safety through expert start-up, repair, calibration, and maintenance.
Convenient, customer-centered service and repair helping customers maintain a safe workplace. The experts at Sensidyne have the experience and knowledge to keep gas detectors performing at their peak.
Factory Commissioning & Service
![Page 17: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/17.jpg)
17
Remote Sensor MountingExtension kits are provided to mount sensors high, low or in difficult locations – up to 50ft (16m) with SensAlert and 100ft (30m) with SensAlert Plus
Remote Calibration AdaptersUsed with remote sensors for routine calibration or bump testing from the transmitter location
ToD™ Gas GeneratorThe unique ToD cell manually or automatically bump tests the sensor at user set intervals with a configurable result notification
Duct Mount FixtureProvides general duct, vent hood, or air intake monitoring for gases
RainshieldPrevents wind blown water from contacting the sensor and adversely affecting performance
Flow Through Cell (Flowblock)Used in sampling systems to present sample to the gas sensor
Moisture/Particulate BarrierSnap in membrane protects sensor from dust, particles, and reduces moisture transients
Aspirated Sample DrawUses an air aspirator to draw a sample from a confined space, ceiling or other difficult to access location
Pumped Sample DrawSame as above but employs a motorized pump to draw a sample
Part # Description
009824-78 Ammonia, 150 ppm in Nitrogen
009824-57 Ammonia, 25 ppm in Nitrogen
009824-67 Ammonia, 300 ppm in Nitrogen
009824-38 Ammonia, 50 ppm in Nitrogen
009824-4 Carbon Monoxide, 50 ppm in Nitrogen
009824-44 Chlorine, 10 ppm in Nitrogen
009824-53 Chlorine, 2 ppm in Nitrogen
009824-34 Chlorine, , 5 ppm in Nitrogen
009824-37 Hydrogen Chloride, 10 ppm in Nitrogen
009824-56 Hydrogen Chloride, 5 ppm in Nitrogen
009824-42 Hydrogen Chloride, 50 ppm in Nitrogen
Part # Description
009824-54 Hydrogen Cyanide, 10 ppm in Nitrogen
009824-79 Hydrogen Cyanide, 25 ppm in Nitrogen
009824-6 Hydrogen, 2 %vol / 50 %LEL in Air
009824-3 Methane 2.5 %vol / 50 %LEL in Air
009824-2 Methane, 1.5 %vol / 30 %LEL in Air
009824-61 Propane 1.05%Vol / 50 %LEL in Air
009824-39 Sulfur Dioxide, 10 ppm in Nitrogen
009824-8 Sulfur Dioxide, 5 ppm in Nitrogen
009824-12 Zero Air, 100% Volume,
009824-25 Zero Gas for others incl. IR, 20.9% O2
009824-15 Zero Gas for Infrared 100% Nitrogen
Tools to solve difficult gas detection applications and maintain calibration.
Accessories and Calibration
Remote Sensor Kit STD 821-0207-01 XP 821-0207-02
Sensor Head O-ring
821-0217-01
Remote Calibration Adapter 821-0218-01
Moisture Barrier 821-0201-01
Flow Block 821-0202-01
Sensor Shield 821-0214-01
Rainshield 821-0203-01
Calibration Plug 821-0223-01
Calibration Gases and Accessories
Sensidyne offers many calibration gases in ranges to meet most applications. The list below represents common calibration gases, contact the factory for a complete list of available calibration gases.
Bayonet Sensor Holder 821-0209-01
Bayonet Remote Calibration Adapter 7013442
Duct Mount Accessory 821-0209-02
Test-On-Demand (ToD) Type S 821-0204-06Type C 821-0204-02
![Page 18: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/18.jpg)
Plus
Ser
ies
sens
ors
are
com
patib
le w
ith S
ensA
lert
ASI
, Sen
sAle
rt P
lus,
and
Sen
sAla
rm P
lus.
Plus
Ser
ies
Sen
sor D
ata
Part
N
umbe
rTa
rget
Gas
or V
apor
Sens
or D
ata
Gas
Dat
a 2To
DCe
llRe
spon
se T
ime
Envi
ronm
enta
lDe
faul
t Ala
rms
Sens
Aler
t 4
Chan
nel 6
Span
4FM
7Ty
pe 1
3Fo
rmul
aDe
nsity
TLV-
TWA
IDLH
T50 5
T90 5
Tem
p °F
Hum
idity
Low
High
Hi-H
igh
823-
0249
-51
Ace
tyle
ne IR
50%
LEL
Infr
ared
C2H2
0.9
Asph
yxia
te- -
n/a
- -45
-4° t
o 13
1°0-
95%
RH
Survey potential interfering gases or vapors for the application and check the Sensor Data Sheet for known interferences.10
2050
Yes
823-
0201
-22
Am
mon
ia50
ppm
FMEC
-LI,
D3N
H30.
625
ppm
300
ppm
n/a
1170
-4° t
o 12
2°15
-90%
RH
1525
35Ye
s
823-
0201
-21
Am
mon
ia10
0 pp
mFM
EC-L
I, D
NH3
0.6
25 p
pm30
0 pp
mn/
a11
70-4
° to
122°
15-9
0% R
H25
3575
Yes
823-
0201
-41
Am
mon
ia30
0 pp
mFM
EC-L
I, D
NH3
0.6
25 p
pm30
0 pp
mn/
a10
50-4
° to
122°
15-9
0% R
H35
7515
0Ye
s
823-
0201
-42
Am
mon
ia50
0 pp
mFM
EC-L
I, D
NH3
0.6
25 p
pm30
0 pp
mn/
a10
50-4
° to
122°
15-9
0% R
H50
100
- -N
o
823-
0212
-21
Ars
ine
1.00
ppm
EC, N
D3As
H32.
70.
05 p
pm3
ppm
S- -
30-4
° to
113°
10-9
5% R
H0.
100.
200.
50Ye
s
823-
0222
-21
Bro
min
e10
ppm
FMEC
, DBr
25.
53.
0 pp
m3
ppm
C- -
40-4
° to
122°
15-9
0% R
H- -
- -- -
No
823-
0222
-41
Bro
min
e1.
00 p
pmEC
, DBr
25.
53.
0 pp
m3
ppm
C- -
45-4
° to
122°
15-9
0% R
H- -
- -- -
No
823-
0205
-52
Car
bon
Diox
ide
IR5.
00%
Vol
.FM
Infr
ared
CO2
1.5
0.50
%3.
00%
n/a
- -30
-4° t
o 12
2°0-
95%
RH
0.5
1.0
3.0
Yes
823-
0219
-23
Car
bon
Mon
oxid
e 10
0 pp
mFM
EC, N
DCO
0.94
25 p
pm1,
200
ppm
n/a
1030
-4° t
o 12
2°15
-90%
RH
2550
75Ye
s
823-
0219
-22
Car
bon
Mon
oxid
e 50
0 pp
mFM
EC, N
DCO
0.94
25 p
pm1,
200
ppm
n/a
1030
-4° t
o 12
2°15
-90%
RH
2575
200
Yes
823-
0219
-43
Car
bon
Mon
oxid
e10
00 p
pmFM
EC, N
DCO
0.94
25 p
pm1,
200
ppm
n/a
1030
-4° t
o 12
2°15
-90%
RH
2575
- -N
o
823-
0219
-41
Car
bon
Mon
oxid
e10
0 pp
mFM
EC-L
I, D
CO0.
9425
ppm
1,20
0 pp
mn/
a10
30-4
° to
122°
15-9
0% R
H25
5075
Yes
823-
0219
-42
Car
bon
Mon
oxid
e50
0 pp
mFM
EC-L
I, D
CO0.
9425
ppm
1,20
0 pp
mn/
a10
30-4
° to
122°
15-9
0% R
H25
7520
0Ye
s
823-
0202
-22
Chl
orin
e 5.
00 p
pmFM
EC, N
DCl
22.
50.
5 pp
m10
ppm
C10
40-4
° to
122°
15-9
0% R
H0.
51
15Ye
s
823-
0202
-42
Chl
orin
e (H
2S R
esist
ant)
5.00
ppm
EC, N
DCl
22.
50.
5 pp
m10
ppm
C- -
45-4
° to
122°
15-9
0% R
H35
115
Yes
823-
0202
-21
Chl
orin
e 10
.0 p
pmFM
EC, N
DCl
22.
50.
5 pp
m10
ppm
C10
40-4
° to
122°
15-9
0% R
H0.
51.
01.
5Ye
s
823-
0202
--41
Chl
orin
e (H
2S R
esist
ant)
10.0
ppm
EC, N
DCl
22.
50.
5 pp
m10
ppm
C- -
45-4
° to
122°
15-9
0% R
H0.
51.
01.
5Ye
s
823-
0202
-23
Chl
orin
e 20
.0 p
pmEC
, ND
Cl2
2.5
0.5
ppm
10 p
pmC
1030
-4° t
o 12
2o15
-90%
RH
25
10N
o
823-
0202
-43
Chl
orin
e (H
2S R
esist
ant)
100
ppm
EC, N
DCl
22.
50.
5 pp
m10
ppm
C- -
45-4
° to
122o
15-9
0% R
H5
1020
Yes
823-
0239
-41
Chl
orin
e Di
oxid
e1.
00 p
pmFM
EC, N
DCl
O2
2.3
0.1
ppm
5 pp
mC
- -30
-4° t
o 12
2o15
-90%
RH
0.10
0.30
0.50
Yes
823-
0239
-42
Chl
orin
e Di
oxid
e5.
00 p
pmFM
EC, N
DCl
O2
2.3
0.1
ppm
5 pp
mC
30-4
° to
122o
15-9
0% R
HN
o
823-
0211
-31
Com
busti
bles
, Gen
eral
100%
LEL
FMCa
taly
tic- -
- -As
phix
iate
- -n/
aT-
60: <
12 se
c-4
0° to
167°
0-90
% R
H10
2050
Yes
823-
0211
-33
Com
b. H
2, E
TO, A
cety
lene
100%
LEL
Cata
lytic
- -- -
Asph
ixia
te- -
n/a
T-60
: <5
sec
-13°
to16
7°0-
90%
RH
1020
50Ye
s
823-
0210
-41
Hyd
roge
n Sp
ecifi
c LE
L10
0% L
ELEC
, ND
H20.
07As
phix
iate
- -n/
a40
120
-4° t
o 12
2o15
-90%
RH
1020
50Ye
s
Part
N
umbe
rTa
rget
Gas
or V
apor
Span
4FM
7Ty
pe 1
3Fo
rmul
aDe
nsity
TLV-
TWA
IDLH
ToD
T50 5
T90 5
Low
High
Hi-H
igh
Sens
Aler
t 4
Chan
nel 6
Sens
or D
ata
Gas
Dat
a 2Ce
llEn
viro
nmen
tal
Defa
ult A
larm
s
![Page 19: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/19.jpg)
D
etec
tion
at e
very
poi
nt.
19
Part
N
umbe
rTa
rget
Gas
or V
apor
Sens
or D
ata
Gas
Dat
a 2To
DCe
llRe
spon
se T
ime
Envi
ronm
enta
lDe
faul
t Ala
rms
Sens
Aler
t 4
Chan
nel 6
Span
4FM
7Ty
pe 1
3Fo
rmul
aDe
nsity
TLV-
TWA
IDLH
T50 5
T90 5
Tem
p °F
Hum
idity
Low
High
Hi-H
igh
823-
0211
-51
Com
busti
bles
IR10
0% L
ELFM
Infr
ared
Hydr
ocar
bons
Asph
ixia
te- -
n/a
T-60
: <12
sec
-13°
to 1
67o
0-99
% R
H
Survey potential interfering gases or vapors for the application and check the Sensor Data Sheet for known interferences.
1020
50Ye
s
823-
0249
-51
Com
busti
bles
IR A
cety
lene
50%
LEL
Infr
ared
C2H2
0.9
2,50
0 pp
m- -
n/a
T-60
: <16
sec
-4° t
o 12
2o0-
95%
RH
1020
50Ye
s
823-
0229
-21
Dib
oran
e1.
00 p
pmEC
, ND
B2H6
2.9
0.1
ppm
15 p
pmS
- -30
0-4
° to
113o
10-9
5% R
H0.
10.
20.
5Ye
s
823-
0245
-21
Eth
ylen
e O
xide
(ETO
)10
.0 p
pmFM
EC, N
DC2
H4O
1.5
1 pp
m80
0 pp
mn/
a15
140
-4° t
o 10
4o15
-95%
RH
12
3Ye
s
823-
0215
-21
Flu
orin
e 10
.0 p
pmEC
, ND
F21.
30.
1 pp
m25
ppm
C10
30-4
° to
122o
15-9
0% R
H1
5- -
No
823-
0215
-22
Flu
orin
e 25
.0 p
pmEC
, ND
F21.
30.
1 pp
m25
ppm
C10
30-4
° to
122o
15-9
0% R
H1
5- -
No
823-
0230
-21
Ger
man
e1.
00 p
pmEC
, ND
GeH4
2.7
0.2
ppm
- -S
- -30
-4° t
o 11
3o10
-95%
RH
0.20
0.50
1.00
Yes
823-
0210
-21
Hyd
roge
n Sp
ecifi
c PP
M10
00 p
pmFM
EC, N
DH2
0.07
Asph
ixia
te- -
n/a
2070
-4° t
o 12
2o15
-90%
RH
100
250
500
Yes
823-
0210
-41
Hyd
roge
n Sp
ecifi
c LE
L10
0% L
ELEC
, ND
H20.
07As
phix
iate
- -n/
a40
120
-4° t
o 12
2o15
-90%
RH
1020
50Ye
s
Use
HCl
Hyd
roge
n Br
omid
e10
.0 p
pmEC
, ND
HBr
2.8
3 pp
m30
ppm
n/a
No
823-
0208
-21
Hyd
roge
n Ch
lorid
e 10
.0 p
pmFM
EC, N
DHC
l1.
32
ppm
50 p
pmS
1530
-4° t
o 12
2o15
-95%
RH
5.0
10.0
- -N
o
823-
0208
-22
Hyd
roge
n Ch
lorid
e 20
.0 p
pmFM
EC, N
DHC
l1.
32
ppm
50 p
pmS
1530
-4° t
o 12
2o15
-95%
RH
5.0
10.0
15.0
Yes
823-
0208
-41
Hyd
roge
n Ch
lorid
e 10
0 pp
mEC
, ND
HCl
1.3
2 pp
m50
ppm
S12
40-4
° to
122o
15-9
5% R
H10
.020
.030
.0Ye
s
823-
0203
-21
Hyd
roge
n Cy
anid
e 20
.0 p
pmFM
EC, D
3HC
N0.
94.
7 pp
m50
ppm
n/a
1030
-4° t
o 12
2o15
-95%
RH
4.0
6.0
10Ye
s
823-
0203
-41
Hyd
roge
n Cy
anid
e 10
0 pp
mEC
, DHC
N0.
94.
7 pp
m50
ppm
S10
60-4
° to
122o
15-9
5% R
H4
20- -
No
823-
0207
-21
Hyd
roge
n Fl
uorid
e 10
.0 p
pmFM
EC, D
HF0.
70.
5 pp
m30
ppm
C15
45-4
° to
122o
15-9
0% R
H2.
03.
07.
0Ye
s
823-
0207
-22
Hyd
roge
n Fl
uorid
e 20
.0 p
pmFM
EC, D
HF0.
70.
5 pp
m30
ppm
C15
45-4
° to
122o
15-9
0% R
H2.
03.
0- -
No
823-
0206
-22
Hyd
roge
n Su
lfide
50
ppm
FMEC
, ND
H2S
1.2
10 p
pm10
0 pp
mS
1030
-40o
to 1
22°
15-9
0% R
H10
1530
Yes
823-
0206
-21
Hyd
roge
n Su
lfide
10
0 pp
mFM
EC, N
DH2
S1.
210
ppm
100
ppm
S10
30-4
0o to
122
°15
-90%
RH
1015
30Ye
s
823-
0206
-23
Hyd
roge
n Su
lfide
10
ppm
FMEC
, ND
H2S
1.2
10 p
pm10
0 pp
mS
1030
-4o
to 1
22°
15-9
0% R
H10
15N
o
823-
0253
-21
Met
hano
l50
0ppm
FMEC
, ND
CH4O
1.1
200p
pm60
00pp
mn/
a15
60-4
° to
122o
15-9
0% R
HN
o
823-
0242
-21
Nitr
ic O
xide
10
0 pp
mEC
, ND
NO
125
ppm
100
ppm
S5
15-4
° to
122o
15-9
0% R
H25
5075
Yes
823-
0221
-21
Nitr
ogen
Dio
xide
10
.0 p
pmFM
EC, N
DN
O2
1.6
1 pp
m20
ppm
C10
40-4
° to
122o
15-9
0% R
H3.
05.
09.
0Ye
s
823-
0240
-22
Oxy
gen
25.0
%Vo
lFM
EC, D
O2
1.1
<19.
5%<1
8%n/
a10
15-4
° to
122o
0-90
% R
H19
.523
.518
.0Ye
s
823-
0243
-22
Ozo
ne (a
lso P
LUS
1.00
ppm
)2.
00 p
pmEC
, ND
O3
1.6
0.1
ppm
5 pp
mC
- -15
0-4
° to
104o
15-9
0% R
H0.
100.
200.
50Ye
s
823-
0247
-21
Pho
sgen
e1.
00 p
pmEC
, ND
COCl
23.
40.
1 pp
m2
ppm
C60
120
-4° t
o 12
2o15
-90%
RH
0.1
0.5
- -N
o
823-
0213
-21
Pho
sphi
ne1.
00 p
pmEC
, ND
PH3
1.2
0.3
ppm
50 p
pmS
- -30
-4° t
o 11
3o10
-95%
RH
0.15
0.30
0.60
Yes
823-
0214
-21
Sila
ne10
.0 p
pmEC
, ND
SiH4
1.3
5 pp
m- -
S- -
30-4
° to
113o
10-9
5% R
H2.
55.
07.
5Ye
s
823-
0218
-22
FM S
ulfu
r Dio
xide
, H2S
Filt
ered
10.0
ppm
FMEC
, ND
SO2
2.3
2 pp
m10
0 pp
mn/
a10
15-4
° to
122o
15-9
0% R
H2.
04.
0- -
No
823-
0218
-21
FM S
ulfu
r Dio
xide
, H2S
Filt
ered
20.0
ppm
FMEC
, ND
SO2
2.3
2 pp
m10
0 pp
mn/
a10
15-4
° to
122o
15-9
0% R
H2.
04.
08.
0Ye
s
Part
N
umbe
rTa
rget
Gas
or V
apor
Span
4FM
7Ty
pe 1
3Fo
rmul
aDe
nsity
TLV-
TWA
IDLH
ToD
T50 5
T90 5
Low
High
Hi-H
igh
Sens
Aler
t 4
Chan
nel 6
Sens
or D
ata
Gas
Dat
a 2Ce
llEn
viro
nmen
tal
Defa
ult A
larm
s
1 Te
rms:
EC
= El
ectr
oche
mic
al, L
I = L
ow In
terf
eren
ce, D
= D
eple
ting
Sens
or, N
D =
Non
-Dep
letin
g Se
nsor
.2
Gas
Dat
a ar
e fr
om A
CGIH
(TLV
-TW
A) a
nd N
IOSH
(ID
LH) b
ut m
ay b
e no
ted
as C
eilin
g or
STE
L. T
he u
ser i
s re
spon
sibl
e fo
r ver
ifyin
g ta
ble
data
.3
D: S
enso
r life
is d
irect
ly p
ropo
rtio
nal t
o ta
rget
gas
exp
osur
e. N
D: S
enso
r is
not d
eple
ted
by e
xpos
ure
to ta
rget
ga
s an
d lif
e is
exp
ecte
d to
be
mor
e th
an 2
yea
rs.
4 L
ower
Det
ectio
n Li
mit
is 3
% o
f Spa
n. N
umbe
r of z
eros
indi
cate
s se
nsor
and
dis
play
reso
lutio
n.5
Nom
inal
sen
sor r
espo
nse
time
whi
ch s
low
s w
ith a
ge, fl
ame
arre
stor
or fi
lters
. 6
No
mea
ns th
at th
e 4-
Chan
nel C
ontr
olle
r will
not
reco
gniz
e th
e se
nsor
- N
o Au
to C
onfig
urat
ion
on 4
Ch7
FM in
dica
tes
the
sens
or is
Per
form
ance
Cer
tified
by
Fact
ory
Mut
ual
![Page 20: Library/gas-detection... · further simplify maintenance and provide installation flexibility. Shop or field calibrate, then swap sensors under power to minimize maintenance and calibration](https://reader034.fdocuments.net/reader034/viewer/2022050308/5f703c516af1fa358b1e1fc3/html5/thumbnails/20.jpg)
A company of the SCHAUENBURG International GroupSensidyne, LP | 1000 112th Circle North, Suite 100 | St. Petersburg, Florida 33716Tel: 800-451-9444 / +1 727-530-3602 | E-mail: [email protected] | Web: www.SensidyneGasDetection.com
Sensidyne manufactures and distributes high-quality industrial health and safety products
designed to protect personnel and facilities in industrial applications worldwide.
Visit our websites to learn more about products available in your area.
Sensidyne.com | SensidyneGasDetection.com | SensidyneNoiseDosimeters.com