Leviton Manufacturing Co., Inc. · libraries, Power Point presentations, and resource rich PDF...
Transcript of Leviton Manufacturing Co., Inc. · libraries, Power Point presentations, and resource rich PDF...
© Copyright 2005 Leviton Manufacturing Co., Inc. All rights reserved.
C-678A/I5 tp
I-5
Leviton Manufacturing Co., Inc. 59-25 Little Neck Parkway, Little Neck, NY 11362-2591Telephone: 1-800-323-8920 • FAX: 1-800-832-9538Tech Line (8:00AM-7:30PM E.S.T. Monday-Friday): 1-800-824-3005
Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9Telephone: 1-800-469-7890 • FAX: 1-800-563-1853
Leviton S.A. de C.V.General Arista 54-A Col. Argentina, Mexico D.F., C.P. 11270Telephone: 011-525-386-1131, 011-525-386-2052 • FAX: 011-525-386-1797
Visit us on the web at: www.leviton.com
Visit Us on the Web
TTo Find: o Find: • Comprehensive Product Information
and Complete PDF Literature Library
• ez-Find™ visit www.leviton.com: it’san advanced web based product search tool with powerful enhancedreporting features
• Tech Support including: IndustryStandards, National Electric CodeUpdates, FAQ’s, NEMA Charts andWiring Diagrams
• Marketing Programs, ApplicationInformation and Product Ideas, TradeShow and Exhibit Schedule, On-LineRegistration for Seminars and Training
• Where To Buy Leviton Products by Zip Code
• A Service Link for AuthorizedResellers to Check Stock, PlaceOrders, and Check Order Status
• Info About Leviton Including PressReleases and Career Opportunities
• How to Contact Leviton withProduct Questions, LiteratureRequests and Comments AboutOur Website!
And Much More...And Much More...
Where can you find a whole line of Pin & Sleeve
IEC 309 Watertight Mechanical Interlocks?
Leviton’s new Industrial Wiring Device Catalog contains thousands of solutions to your everyday-specialized-industrial wiring device needs. ■ For
example, the 29-page Pin & Sleeve Section includes: ■ A complete line ofNorth American Watertight Plugs, Connectors, Receptacles and Inlets, 20 Amp -
100 Amp ■ International Rated Devices, 16 Amp - 125 Amp ■ MechanicalInterlocks fused and non-fused versions 20 Amp -100 Amp ■ Safety Disconnect
Switches fused and non-fused versions 30 Amp - 100 Amp. ■ In other words,Leviton delivers a complete system of IEC 309-1 & IEC-309-2 compliant products
that improve and enhance safety and performance in mission-critical power applications. ■ To obtain a copy of Leviton’s new edition of the Industrial
Wiring Device Catalog, log on to www.leviton.com/industrial/catalog■ Imagine something better…at Leviton we do every day.
An ISO 9001 Registered Quality Manufacturer.©2005 Leviton Manufacturing Co., Inc.
The same place you'll find 3,394 other best-in-quality products that have earned world-class brand recognition.
LEVITON MANUFACTURING Co., Inc., 59-25 Little Neck Parkway, Little Neck, New York 11362-2591 www.leviton.com/powerquality
Table of ContentsLeviton Website - General Description & Information . . . . . . . . . . . . . . . .Inside Front Cover
Power Quality Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Power Quality Product Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Panel Mounted DevicesPanel Mounted Devices - 74000 & 75000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4Panel Mounted Devices - 37000, 47000 & 52000-7M3 Series . . . . . . . . . . . . . . . . . . . . .5-6Panel Mounted Devices - 57000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8Panel Mounted Devices - 52000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10Multi-Phase Panel Protectors - 32000 & 42000 Series . . . . . . . . . . . . . . . . . . . . . . . . . .11-12Panel Mounted Devices - 51110 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Multi-Phase Panel Protectors - 51120 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Secondary Surge Arresters - 50240 & 50208 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Secondary Surge Arresters - 54175, 55175 & 55650 Series . . . . . . . . . . . . . . . . . . . . . . . .16
Wired-In Protective ModulesWired-In Surge Protective Modules - 51015, 51020 & 51240 Series . . . . . . . . . . . . . . . . .17Wired-In Surge Protective Modules - 51005 & 51010 Series . . . . . . . . . . . . . . . . . . . . . . .18Equipment Cabinet SPD’s - 3800 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Low-Voltage Protection Modules - 3400 & 3800 Series . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Wired-In ReceptaclesWired-In Receptacles - 5280, 5380, 7280, 7380, 8280, 8380, 8281 & 8381 Series . . .21-22Wired-In Four-In-One Receptacles - 5480, 5490, 8480 & 8490 Series . . . . . . . . . . . . .23-24DIN-Rail Mountable Receptacles - 3880-DIN, 3801-DIN, 8598-DIN & 16252-DIN . . . . .25
Plug-In DevicesModular Surge Protective Strips - 5950 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Plug-In Modules - 5951, 5952, 5953, 5954, 5955, 5957, 5958 & 5959 Series . . . . . . . . . 27Six-Outlet Plug Strips - 5300 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Six-Outlet Plug Strips - 5100 & 5200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Plug Strips & Plug-Ins - 3500, 4800 & 4900 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Four-Outlet SPD’s & Plug Strips - 4950, 5100 & 5300 Series . . . . . . . . . . . . . . . . . . . . . . .31Rack-Mount Devices - 5500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Rack-Mount Devices - 4505, 2119D, 1524D & KFL-A1398 . . . . . . . . . . . . . . . . . . . . . . .33
Communications & Data Line SPD’sLow-Voltage & Data Line SPD’s - 5350 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Lev-UPS™ DevicesOnline Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-36Sine Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37-38Slim Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40Pro Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-42Strip Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43-44Additional Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45Lev-UPS™ Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47-50
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51-52
Catalog Number Alphanumeric Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-54
Note Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
1 For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Superior Service & Support Programs
Leviton’s Power Quality technical specialists will present comprehensive seminars tailored tothe needs of your facility. The information presented includes coverage of the various types of power quality problems; their origins, effects and how to best address them. Other topicsinclude safety issues, energy efficiency, and Code changes. For additional information or to set up a meeting call 800-648-3332.
Our award winning APTitude interactive software will illustrate how to apply surge protectionand back-up power products. Product information presentations are designed to quickly convey technical data and assist with application and specification information.
Learning Lab Seminars
Power Quality APTitude on CD – Application Product Training
Launch Menu Applications Community Virtual Distribution System
Launch MenuContains 10 buttons or menu choices that launch linked programs to a treasure trove of Power Quality technical informationlibraries, Power Point presentations, and resource rich PDF specification documentation.
Applications CommunitySeven active links to digital, graphic communities: an industrial facility, a commercial building, a school, a hospital, a restaurant,a house, and a traffic control panel.
Virtual Distribution SystemLinks to the facility distribution system where various devices can be tested for events such as spikes and power outages with theresults graphically displayed.
Leviton’s technical specialists will conduct Power QualityAudits in any type of facility. They can assist in identifyingequipment at risk, evaluate potential losses in revenueand productivity due to downtime and recommendeffective power quality application solutions. A uniquetool used is Leviton’s exclusive plug-in surge eventcounter that can easily identify problem areas within a facility.
Trained technical specialists staff Leviton’s Power Quality Techline, (8:00AM - 7:30PM E.S.T Monday-Friday). The toll-free Techline number is (800) 824-3005. Fax: (800) 832-9538Visit Leviton’s Power Quality web site at www.leviton.com/powerquality
Fast Answers to Technical QuestionsCatalog No. 51000-SMC
Plug-in Surge Counter
• 74000/75000 (shown),52000 & 57000Series
• Provides completeprotection on allphases even if onemodule fails; modulardesign allows easyreplacement of modules. NC, NOcontacts for remotestatus indication.
• Models available with surge event counter
• 32000 & 42000Series
• Provides multiple-phase surge protection incommercial andindustrial environ-ments; 3Ø modelsare suitable for WYE and Delta AC systems
• Compact designpermits close installation to panel and provides a shortparallel suppression path
• 55175 & 55650 Series• Designed for 120/240 volt
single-phase and 277/480Vthree-phase
• Rugged housing constructed of outdoor-rated, high-impact thermoplastic
Modular Surge Panels Panel Protectors Surge Arresters
• 51000 Series• Hard wired• For use by OEM’s
who wish toinclude 120/240Vsurge protection
• Available in 5, 10,15 and 20 Ampversions
• DIN-rail mountable
• 3803 Series • Hard wired• For use on Allen
Bradley & 4-20 madevices
• CE approved• Two options for
ground connection• Protects program-
mable logic devicesfrom surges inharsh electromagnetic or geographic areas
• 5280/53807280/73808280/8380
• 15–20 Amp duplex, single and 4-in-1 5480 & 5490 Series configurations
• Protection indicator light and audible damage alarm
• Decora-style matching wallplate included
• IG versions
In-Line Protectors Communication Modules Surge Receptacles
• 5100-IPS• Available in a variety
of grades• Real-time diagnostics
monitor power andsuppression status
• Six protected outlets• Resettable circuit
breaker and internalfusing
• Equipped with 6-foot,14-3AWG power cord
• 3880-DIN• Green LED goes off
when surge protectionis lost
• Audible alarm has anintegral disable (quiet)switch
• Power continues to beprovided to connectedloads in the event ofprotection loss
• 5500 & 5505 Series• Mounts on 19" equipment racks to
provide point-of-use surge suppressionfor electronic equipment
• 6 protected duplex receptacles—5 inrear and 1 in front
• 12-ft. line cord with grounding NEMA5-15P or 5-20P plug
Power Strips DIN-Receptacles Surge Rack-Mounts
• Lev-CON™ line interactive voltage regulation
• Lev-WARE™ UPS monitoring software
• Simulated and Pure Sine-wave versions available
• Prevent losses and costly downtimeassociated with power outages
• Line-interactive technology• Microprocessor control• Advanced battery management• Overload and short-circuit protection
• U1500-SRM, U0600-ARM• Lev-CON™ line interactive
voltage regulation• Lev-WARE™ UPS control &
monitoring software• Surge protection on AC &
communication line• 500VA Capacity
UPS “Tower” Models UPS 19" Rack-Mounts UPS “Slim” Series
74000/75000 Series
Power Quality Product Types
2For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Pages 3-10 Pages 11-14 Page 16
Pages 17-19 Page 20 Pages 21-25
Pages 26, 28-31 Page 25 Pages 32-33
Pages 35-38 Pages 35-37 Pages 39-40
SPECIFICATIONS & FEATURES74000 & 75000 SERIES
• Provides Seven Mode Protection.• User replaceable modules• Real-time diagnostics monitor
power and suppression status for each mode
• Surge magnitude, time, and date is provided for each surge event.
• Surge event history downloadable for storage via RS-232 connection.
• AC Sine Wave Tracking• Optically isolated dry contacts
• UL 1449 2nd Edition Listed
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
NEC200 KAIC Rated per Article 285
CSA#LR-94773
Panel Mounted Devices74000 & 75000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
3
DESCRIPTION CATALOG NO. VOLTAGE RATING MODULE NO.3ø WYE (4-Wire + Ground)
7-Mode, 3ø WYE, 4-Wire + Ground 74120-7M3 120/208V AC (7) HC120-M407-Mode, 3ø WYE, 4-Wire + Ground 74277-7M3 277/480V AC (7) HC277-M407-Mode, 3ø WYE, 4-Wire + Ground 75120-7M3 120/208V AC (7) HC120-M537-Mode, 3ø WYE, 4-Wire + Ground 75277-7M3 277/480V AC (7) HC277-M53
74000 & 75000 Series
Diagnostic Capabilities:• Monitors the status of each phase.
• Display will indicate “Fault”, “Alert”, and “Protection” status.
• Functions include a surge event counter, amplitude measurement, date and time stamping of the event.
• Events are stored and are recallable and downloadable by the user.
Normal Operations:• Green indicator lights illuminate when the panel status is OK. A fault condition is indicated when up to 3 indicators are no longer illuminated.
• Yellow indicator light will illuminate and audible alarm will sound when one of the fuses in the surge module opens due to surge activity. The percentage of protection in that module will flash on the screen (i.e., 75% protection when 1 fuse is open).
• Red indicator light will illuminate and audible alarm will sound when protection level is at 50% or less.
• Arrow buttons allow user to view surge event history on each line by scrolling through data.
• Information is easily downloadable via RS-232 port using the program “Hyperterminal” that comes standard on any Windows operating software (see instruction sheet for detailed instructions).
74120-7M3Type 12
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in kA NOISE6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-N + L-G = “per Phase”
74120-7M3 150V AC 400 400 400 200 200 400 -40 dB(@ 5kHz-100MHz)
74277-7M3 320V AC 800 800 800 200 200 400 -40 dB(@ 5kHz-100MHz)
75120-7M3 150V AC 400 400 400 320 320 640 -20 to -40 db(@ 5kHz-100MHz)
75277-7M3 320V AC 800 800 800 320 320 640 -20 to -40 db(@ 5kHz-100MHz)
Panel Mounted Devices74000 & 75000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
SURGE COUNTERPROTECTION STATUS
LINE 1
LINE 2
LINE 3
N-G
74000 & 75000 SERIES
4
74000 & 75000 Series
Diagnostic display panel on the 74000 and75000 Series uses LED display to indicate“Fault”, “Alert”, and “Protection” status.
75000 Series modules are designed withfour arrester grade MOV's each ratedfor 80,000 Amps, 8x20us Impulse. Eachmodule is tested to maximum levels of surgecurrent at an independent laboratory.
Large-diameter MOV's, 40mm on 74000Series panels and 53mm on the 75000Series, are individually thermal fused forover-current protection.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.3ø WYE (4-Wire + Ground)
7-Mode Panel Mount 37120-007 – 120/208V AC –Type 1 Enclosure (4-Wire + Ground) 7-Mode Panel Mount w/ NEMA 37277-007 – 277/480V AC –Type 1 Enclosure (4-Wire + Ground) 7-Mode Panel Mount 47120-007 – 120/208V AC –(4-Wire + Ground)7-Mode Panel Mount w/ NEMA 47120-4X7 – 120/208V AC –4X Enclosure (4-Wire + Ground) 7-Mode Panel Mount 47277-007 – 277/480V AC –(4-Wire + Ground)7-Mode Panel Mount w/ NEMA 47277-4X7 – 277/480V AC –4X Enclosure (4-Wire + Ground)7-Mode Panel Mount 47347-007 – 347/600V AC –(4-Wire + Ground)7-Mode Modular Panel Mount 52120-7M3 52120-7C3 120/208V AC (3) 120-7M3(4-Wire + Ground) (1) 8120-GN7-Mode Modular Panel Mount 52277-7M3 52277-7C3 277/480V AC (3) 220-7M3(4-Wire + Ground) (1) 8120-GN
SPECIFICATIONS & FEATURES37000, 47000 & 52000-7M3 SERIES
• Provides Seven Mode Protection.
• 47000 Series available in NEMA 1 or 4X enclosure. 52000-7M3 Series comes in a NEMA 12 enclosure withFlush Mount Collar.
• Dry contacts for remote monitoring (NO-C-NC). LED’s provide indication of protection status of each mode.
• Design of the 52000-7M3 allows for easy replacement of modules.
• UL 1449 2nd Edition Listed
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
NEC200 KAIC Rated per Article 285
CSA#LR-94773
Panel Mounted Devices37000, 47000 & 52000-7M3 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
5
47120-007Type 1 52120-7M3
Type 12
47120-4X7Type 4X
37000, 47000 & 57000-7M3 Series
37277-007Type 1
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Remote Supervisor Provides Clear Indication of Protection StatusAll Leviton Panel mounted SPD’s are equipped with real-time diagnostics that indicate protection status. However, when these units are mounted in electrical closets, or other out-of-the-way locations, a diagnostic alert might not be seen or heard for some time.
The 52000-RS Remote Supervisor can relay protection failure or power interruption warnings from one or more Leviton panel-mounted SPD’s. Warnings are provided by an optically coupled sensor anddata lines comprising up to 5000 feet of #20 or #22 twisted-pair wiring. One Remote Supervisor canmonitor up to six panel-mounted SPD’s. The Remote Supervisor provides both a visual and audiblealert, which can be silenced at the press of a button. The unit is equipped with a test circuit, anddesigned for surface mounting. It draws power from any 120V source through a six-foot line cord.
CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in kA NOISE6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-L L-N + L-G = “per Phase”
37120-007 140V AC 400 500 400 700 100 100 200 -30 to -40 db37277-007 320V AC 800 900 800 1500 100 100 200 (@ 10kHz-10MHz)
47120-007 140V AC 330 400 330 600 200 200 400 -40 dB47120-4x7 (@ 10kHz-10MHz)
47277-007 320V AC 700 800 700 1500 200 200 400 -40 dB47277-4x7 (@ 10kHz-10MHz)
47347-007 390V AC 1200 1300 1200 2200 200 200 400 -40 dB(@ 10kHz-10MHz)
52120-7M3 150V AC 400 500 400 800 100 100 200 -20 to -40 db52120-7C3 (@ 5kHz-100MHz)
52277-7M3 320V AC 800 900 800 1500 100 100 200 -20 to -40 db52277-7C3 (@ 5kHz-100MHz)
37000, 47000 & 57000-7M3 Series
Panel Mounted Devices37000, 47000 & 52000-7M3 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
4"
(101.6mm) 10"(254mm)
10"
11"
(279
.4m
m)
(254
mm
)
Green LEDIndicators
NEMA Type 1Metal Enclosure
Color: Gray
11x11 InchFlush Mount
Cover
37120-007, 37277-007, 47120-007,47277-007, 47347-007
47120-4X7, 47277-4X7 52000 Series
11.25" (285.8mm) 5.69" (144.5mm)
13.50"(342.9mm
)
6
Catalog No.52000-RS
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.3ø WYE (4-Wire + Ground)
3ø WYE, 4-Wire & Ground 57120-M3 57120-CM3 120/208V AC (3) 120(1) 8120-GN
3ø WYE 7-Mode, Integral 57120-M3S 57120-C3S 120/208V AC (3) 120-M3SDisconnect, 4-Wire & Ground (1) 8120-GN3ø WYE, 4-Wire & Ground 57220-IM3 –– 220/380V AC (3) 220
(1) 8250-GN3ø Delta, 3-Wire & Ground 57240-DM3 – 240V AC (3) 72403ø WYE, 4-Wire & Ground 57277-M3 57277-CM3 277/480V AC (3) 7277
(1) 8320-GN3ø WYE 7-Mode, Integral 57277-M3S 57277-C3S 277/480V AC (3) 7277-M3SDisconnect, 4-Wire & Ground (1) 8320-GN3ø WYE, 4-Wire & Ground 57346-M3 – 346/600V AC (3) 7346
(1) 8385-GN3ø WYE, 4-Wire & Ground 57347-M3S – 347/600V AC (3) 7347
(1) 8385-GN3ø Delta, 3-Wire & Ground 57480-DM3 – 480V AC (3) 74803ø Delta, 3-Wire & Ground 57600-DM3 – 600V AC (3) 7600
SPECIFICATIONS & FEATURES57000 SERIES
• Available with NEMA 12 enclosure.Flush mount collar included with most units.
• Dry contacts for remote monitoring (NO-C-NC).
• Modular design allows for easy replacement of modules.
• Features Sine-Wave Tracking and Redundant Protection.
• UL 1449 2nd Edition Listed.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
FLAMMABILITY
UL945-VFlame Retardant Thermoplastic
(Front Bezel)
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
NEC200 KAIC Rated per Article 285
CSA#LR-94773
Panel Mounted Devices57000 Series - For Service Entrance or Branch Panels
10 YEAR LIMITED
Replacement Modules for Superior ProtectionThe heart of the Cat. No. 57000 group is the powerful Replacement Module equipped with extremelyeffective hybrid multi-component suppression circuitry. Six different module variants are available to suita range of commonly available North American AC line-voltage configurations.
7
57000 Series
57120-M3Type 1
57120-CM3Type 12
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Panel Mounted Devices57000 Series - For Service Entrance or Branch Panels
10 YEAR LIMITED
1.53(38.9 mm) 3.28 (83.3 mm)
4.41
(11
2.0
mm
)
57000 SERIES 57000-M3S 52000-RS
20.0
0 (5
08.0
mm
)
®
16.00 (406.4 mm) 6.80 (172.7 mm)
8.02(203.7 mm)
8
CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in kA NOISE6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-L L-N + L-G = “per Phase”
57120-M3 150V AC 400 800 400 800 150 – 150 -20 to -40 dB57120-CM3 (@ 5kHz-10MHz)
57120-M3S 150V AC 400 500 400 700 100 100 200 -20 to -40 dB57120-C3S (@ 5kHz-10MHz)
57220-IM3 250V AC 600 1200 600 1200 150 – 150 -20 to -40 dB(@ 5kHz-10MHz)
57240-DM3 250V AC – – – 700 -20 to -40 dB(@ 5kHz-10MHz)
57277-M3 320V AC 800 1800 800 1800 150 – 150 -20 to -40 dB57277-CM3 (@ 5kHz-10MHz)
57277-M3S 320V AC 900 1000 800 1500 100 100 200 -20 to -40 dB57277-C3S (@ 5kHz-10MHz)
57346-M3 385V AC 1000 2000 1000 2000 150 – 150 -20 to -40 dB(@ 5kHz-10MHz)
57480-DM3 550V AC – – – 1500 -20 to -40 dB(@ 5kHz-10MHz)
57600-DM3 680V AC – – – 1800 -20 to -40 dB(@ 5kHz-10MHz)
57347-M3S 390V AC 1000 1000 1000 2000 100 100 200 -20 to -40 dB(@ 5kHz-10MHz)
57000 Series
L-L: 150
L-L: 150
L-L: 150
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Remote Supervisor Provides Clear Indication of Protection StatusAll Leviton Panel mounted SPD’s are equipped with real-time diagnostics that indicate protection status. However,when these units are mounted in electrical closets, or other out-of-the-way locations, a diagnostic alert might not beseen or heard for some time.
The 52000-RS Remote Supervisor can relay protection failure or power interruption warnings from one or moreLeviton panel-mounted SPD’s. Warnings are provided by an optically coupled sensor and data lines comprising up to 5000 feet of #20 or #22 twisted-pair wiring. One Remote Supervisor can monitor up to six panel-mounted SPD’s.The Remote Supervisor provides both a visual and audible alert, which can be silenced at the press of a button. The unit is equipped with a test circuit, and designed for surface mounting. It draws power from any 120V sourcethrough a six-foot line cord.
SPECIFICATIONS & FEATURES52000 SERIES
• Available with NEMA 12 enclosure.Flush mount collar included with most units.
• Dry contacts for remote monitoring.
• Features Sine-Wave Tracking
• UL 1449 2nd Edition Listed.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
FLAMMABILITY
UL945-VFlame Retardant Thermoplastic
(Front Bezel)
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
NEC200 KAIC Rated per Article 285
CSA#LR-94773
Panel Mounted Devices52000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
9
DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.
Single Phase, 2-Wire & Ground 52120-M1 – 120V AC (1) 2120(1) 8120-GN
Single Phase, 3-Wire & Ground 52120-M2 52120-CM2 120/240V AC (2) 2120(Home Automation Model) (52120-M2H) (1) 8120-GN3ø WYE, 4-Wire & Ground 52120-M3 52120-CM3 120/208V AC (3) 2120(Without Enclosure) (52120-B3) (1) 8120-GN3ø WYE (International), 52220-IM3 – 220/380V AC (3) 22204-Wire & Ground (1) 8250-GN3ø Delta, 3-Wire & Ground 52240-DM3 – 240V AC (3) 22403ø WYE, 4-Wire & Ground 52277-M3 52277-CM3 277/480V AC (3) 2277
(1) 8320-GN3ø WYE, 4-Wire & Ground 52347-M3 – 347/600V AC (3) 2347
(1) 8385-GN3ø Delta, 3-Wire & Ground 52480-DM3 – 480V AC (3) 2480Split Phase Delta, 52412-DS3 – 120/240V AC (2) 2120 (120V) &4-Wire & Ground (1) 2412 (Hi-Leg)
52000 Series
52120-M3Type 12
52120-CM3 Type 12
52000-RS
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Panel Mounted Devices52000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
52000 SERIES 52000-RS
1.53(38.9 mm) 3.28 (83.3 mm)
4.41
(11
2.0
mm
)
10
CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in kA NOISE6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-L L-N
52120-M1 150V AC 400 800 400 – 100 -20 to -40 dB(@ 5kHz-10MHz)
52120-M2 150V AC 400 800 400 800 100 -20 to -40 dB52120-CM2 (@ 5kHz-10MHz)
52120-M2H 150V AC 400 800 400 800 100 N/A DHC Power LineCarrier Compatible
52120-M3 (B3) 150V AC 400 800 400 800 100 -20 to -40 dB52120-CM3 (@ 5kHz-10MHz)
52220-IM3 250V AC 600 1200 600 1200 100 -20 to -40 dB(@ 5kHz-10MHz)
52240-DM3 L-L: 250V AC – – – 600 100 -20 to -40 dB(@ 5kHz-10MHz)
52277-M3 320V AC 800 1800 800 1800 100 -20 to -40 dB52277-CM3 (@ 5kHz-10MHz)
52347-M3 420V AC 900 – – 900 100 -20 to -40 dBL-L: 680 (@ 5kHz-10MHz)
52480-DM3 550V AC – – – 1500 100 -20 to -40 dB(@ 5kHz-10MHz)
52412-DS3 L-L: 250V AC 400 800 400 800 100 -20 to -40 dB(@ 5kHz-10MHz)
52000 Series
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION CATALOG NO. VOLTAGE RATING
Single Phase 32120-1 120/240V AC42120-1
3ø WYE or 220V AC, 3ø Delta 32120-DY3 120/208V AC42120-DY3
277/480V or 220/380V AC 32277-DY3 277/480V AC, 220/380V AC,3ø WYE or 240, 480V AC 3ø Delta 42277-DY3 480V AC3ø WYE 32347-DY3 347/600V AC
42347-DY3Hi-Leg Split Phase Delta 32412-DS3 120/240V AC
42412-DS3Flush Mount Collar 42001-FMC –
SPECIFICATIONS & FEATURES32000 & 42000 SERIES
• 32000 Series Compatible with Decora Home automation devices.
• Real-time diagnostics via indicatorlights and acoustic alarm.
• Dry contacts for remote monitoring (NO-C-NC).
• Compact design for close installationto panel provides short parallelsuppression path.
• UL 1449 2nd Edition Listed.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
FLAMMABILITY
UL945-VFlame Retardant Thermoplastic
(Front Bezel)
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
NEC200 KAIC Rated per Article 285
CSA#LR-94773
Multi-Phase Panel Protectors32000 & 42000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
32000 & 42000 Series
11
32120-DY3Type 3R 42120-DY3
Type 3R
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Multi-Phase Panel Protectors32000 & 42000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
32000 & 42000 SERIES
6.25
2.25
4.25
3.25
1.001.00
TOP END
(158
.75m
m)
(57.15mm)
(25.4mm)
(108
mm
)
(82.55mm)
7.506.
258.25
FRONT
(209
.55m
m)
(158
.75m
m)
(190
.5m
m)
12
CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in kA NOISE REJECTION NOISE REJECTION6kV/500A (test w/ 8x20us wave) FOR 32000 SERIES FOR 42000 SERIES
L-N N-G L-L L-N
32120-1 150V AC 500 500 700 80kA -20 to -30 dB -30 to -40 dB42120-1 (@ 1.5kHz-1.2MHz) (@ 10kHz-10MHz)
32120-DY3 150V AC 500 500 700 80kA -20 to -30 dB -30 to -40 dB42120-DY3 (@ 1.5kHz-1.2MHz) (@ 10kHz-10MHz)
32277-DY3 320V AC 900 800 1500 80kA -20 to -30 dB -30 to -40 dB42277-DY3 (@ 1.5kHz-1.2MHz) (@ 10kHz-10MHz)
32347-DY3 382V AC 1200 1000 2000 80kA -20 to -30 dB -30 to -40 dB42347-DY3 L-L: 660VAC (@ 1.5kHz-1.2MHz) (@ 10kHz-10MHz)
32412-DS3 132V AC 400 500 800 80kA -20 to -30 dB -30 to -40 dB42412-DS3 L-L: 264V AC (@ 1.5kHz-1.2MHz) (@ 10kHz-10MHz)
32000 & 42000 Series
Accessory
Cat. No. 42001-FMCFlush Mount Cover
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
51110-PTCType 1
SPECIFICATIONS & FEATURES51110 SERIES
• 51110-PTC provides 2-pair telephone/fax/modem protection using hard-wired screw terminations and dual CATV/satellite feed surge protection using type “F” connectors.
• Real-time diagnostic visual indicator shows power and suppression status for each protected phase.
• DHC power line carrier compatible
• Painted steel NEMA 1 enclosure provided with four perforated 7/8” knockouts.
• Flush mount covers provided with unit.
• Surface mount brackets provided with unit.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
Indoor & Outdoor Rated
CSA#LR-94773
Panel Mounted Devices51110 Series - For Residential Environments
10 YEAR LIMITED
DESCRIPTION CATALOG NO.
120/240V AC, Single-Phase 51110-001120/240V AC, Single-Phase w/ 2 Pair Telephone,RJ11 & CATV/Satellite Coax 51110-PTC120/240V AC, Single-Phase w/ 4 Pair Telephone & CATV/Satellite Coax 51110-CT8
51110 Series
13
4.75
8.13
3.50REF
2.22
RE
F
8.13
5.50
6.50
4.00 REF3.00 REF
GREEN LED
FLUSH
CATVF-CONNECTORS
SATF-CONNECTORS
MOUNTING BRACKETS
FLUSH COVER
MOUNTING HOLESFOR #8 SCREWS
51110-PTC & 51110-CT8 SERIES
51110 Series
51110-001Type 4X
51110-001Flush Cover
51110-001
CATALOG NO. MCOV UL 1449 (Second Ed.) IMPULSE 6kV/500A MAX. SURGE CURRENT(Test w/ 8x20us wave)
51110-001 150V AC L-N: 400V L-L: 800V L-N: 48kA51110-PTC 150V AC L-N: 400V L-L: 800V L-N: 48kA51110-CT8 150V AC L-N: 400V L-L: 800V L-N: 48kA
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES51120 SERIES
• Single high-energy solid-state semiconductor surge suppression circuitry per phase.
• Real-time diagnostics visual indicator shows power and suppression status for each protected phase.
• 51120-PTC incorporates phone line protection and TV cable/satellite feed along with AC protection.
• 51120-3R features NEMA 3R-Rated steel enclosure.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449#E146315
Indoor & Outdoor Rated
CSA#LR-94773
Multi-Phase Panel Protectors51120 Series - For Light Commercial & Residential Environments
14
CATALOG NO. MCOV UL 1449 (Second Ed.) IMPULSE 6kV/500A MAX. SURGE CURRENT(Test w/ 8x20us wave)
51120-1 150V AC L-N: 500V L-L: 800V L-N: 50kA51120-3 150V AC L-N: 500V L-L: 800V L-N: 50kA51120-3R 180V AC L-N: 800V L-N: 50kA51120-PTC 150V AC L-N: 500V L-L: 800V L-N: 80kA
DESCRIPTION CATALOG NO.
120/240V AC, Single-Phase 51120-1120/208V AC, 3ø WYE 51120-3120/240V AC, Single-Phase, NEMA 3R Enclosure 51120-3R120/240V AC, Single-Phase w/ 2 Pair Telephone, 51120-PTCRJ11 & CATV/Satellite Coax Module
51120 Series
51120 Series
51120-3 51120-3R 51120-PTC
51120-3Type 1
10 YEAR LIMITED
51120-3RType 3R
51120-PTCType 1
6.25
2.25 1.00
TOP
(158
.75m
m)
(57.15mm)
(25.4mm)
7.506.
258.25
FRONT
(209
.55m
m)
(158
.75m
m)
(190
.5m
m)
4.00 (101.6mm)
4.45 (113.03mm)
6.00 (152.4mm)
2.25 (57.15)
6.50 (165.1mm) .281
(7.14mm)
5.88
(14
9.35
mm
)
(26.92mm)1.06
6.00 (152.4mm)
6.00
(15
2.4m
m)
7.00
(17
7.8m
m)
6.00
(15
2.4m
m)
7.00 (177.8mm)
4.06 (103.12mm)
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
6.94 (176.3 mm)
3.72 (94.5 mm)
6.6
2 (1
68.2
mm
)
CATALOG NO. MCOV UL 1449 (Second Ed.) MAX. SURGE CURRENTIMPULSE 6kV/500A (Test w/ 8x20us wave)
50240-MSA 180V AC L-G: 800V L-G: 80kA50240-ASA 180V AC L-G: 800V L-G: 80kA50240-FMA 180V AC L-G: 800V L-G: 80kA50240-FAA 180V AC L-G: 800V L-G: 80kA50208-ASA 180V AC L-G: 800V L-G: 80kA
DESCRIPTION CATALOG NO. DIAGNOSTICS
120/240, 200A-4 Jaw 50240-MSA LED’s Only120/240, 200A-4 Jaw 50240-ASA LED’s & Audible Alarms (switchable)120/240, 200A-5 Jaw 50240-FMA LED’s Only120/240, 200A-5 Jaw 50240-FAA LED’s & Audible Alarms (switchable)120/208, 200A-7 Jaw, 3ø, 4-Wire 50208-ASA LED’s & Audible Alarms (switchable)
SPECIFICATIONS & FEATURES50240 & 50208 SERIES
• Use of a single, large 53mm MOV per line provides a higher energy capacity than multiple small MOV. Configurationswhere the protection is only as good as the weakest MOV in the chain.
• Constructed of high-impact, non-conductive, fiberglass-reinforced polycarbonate.
• 15 year limited warranty with $10,000 connected equipment coverage for “white-goods” appliances.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE
C-62.11
UL LISTEDSecondary Surge Arrester (OWHX)
CSA#LR-94773
Meter Socket Surge Arrester Adapters50240 & 50208 Series - For Residential Applications
LIMITED
50240 & 50208 Series
15
50240 & 50208 Series
50240 & 50208 SERIES
50240-MSA
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES54175, 55175 & 55650 SERIES
• Unit come with 18” pigtail wires.
• Constructed of high-impact, non-conductive, fiberglass-reinforcedpolycarbonate.
• Compact design for easy installation.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE
C-62.11
UL LISTEDSecondary Surge Arrester (OWHX)
CSA#LR-94773
Secondary Surge Arresters54175, 55175 & 55650 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
16
DESCRIPTION CATALOG NO. DIAGNOSTICS
120/240 54175-SSA None120/240 55175-ASA LED’s & Audible Alarms120/240 55175-SSA None277/480V AC WYE, 480V AC Delta 55650-ASA LED’s & Audible Alarms347/600V AC WYE, 600V AC Delta
54175, 55175 & 55650 Series
CATALOG NO. MCOV UL 1449 (Second Ed.) MAX. SURGE CURRENTIMPULSE 6kV/500A (Test w/ 8x20us wave)
54175-SSA 150V AC* L-N: 400V L-N: 52kA55175-ASA 180V AC L-N: 400V L-N: 70kA55175-SSA 180V AC L-N: 400V L-N: 70kA55650-ASA 480V AC L-N: 1500V L-N: 100kA
54175, 55175 & 55650 Series
* MOV's rated at 150V. UL assigns a derated MCOV of 132V for surge arrester applications.
3.03 (77)1.82 (46.2)
1.1 (27.9)
18.0 (457.2)
2.50
(63
.5)
55175 SERIES 54175 SERIES
55175-ASA
3 1/
8" R
ef
3 1/8" Ref3 1/8" Ref
Black 10 AWG
White 10 AWG
54175-SSA
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CATALOG NO. MCOV UL 1449 (Second Ed.) IMPULSE 6kV/500A MAX. SURGE CURRENT NOISE REJECTION(Test w/ 8x20us wave)
51015-WM 150V AC L-N:330V L-G: 330V N-G: 400V L-N: 52kA 20-30 dB (@ 100kHz-10MHz)
51020-WM 150V AC L-N:330V L-G: 330V N-G: 400V L-N: 52kA 20-30 dB (@ 100kHz-10MHz)
51015-DIN 150V AC L-N:330V L-G: 330V N-G: 400V L-N: 52kA 20-30 dB (@ 100kHz-10MHz)
51020-DIN 150V AC L-N:330V L-G: 330V N-G: 400V L-N: 52kA 20-30 dB (@ 100kHz-10MHz)
51020-WMT 150V AC L-N:330V L-G: 330V N-G: 400V L-N: 52kA 20-30 dB (@ 100kHz-10MHz)
51240-WM 270V AC L-N:600V L-G: 330V N-G: 600V L-N: 52kA 40-50 dB (@ 5kHz-100MHz)
51240-DIN 270V AC L-N:600V L-G: 330V N-G: 600V L-N: 52kA 40-50 dB (@ 5kHz-100MHz)
DESCRIPTION CATALOG NO. RATING
Single-Phase, 3-Wire 51015-WM 120V AC 15A Single-Phase, 3-Wire 51020-WM 120V AC 20A Single-Phase, 3-Wire, DIN-Rail Mounting 51015-DIN 120V AC 15A Single-Phase, 3-Wire, DIN-Rail Mounting 51020-DIN 120V AC 20A Single-Phase, 3-Wire 51020-WMT 120V AC 20A (For use in parallel connection)Single-Phase, 3-Wire 51240-WM 240V AC 20A Single-Phase, 3-Wire, DIN-Rail Mounting 51240-DIN 240V AC 20A
SPECIFICATIONS & FEATURES51015, 51020 & 51240 SERIES
• Staged multi-component surge suppression circuitry provides clamping envelope that follows AC sine wave contour.
• DIN rail mounting versions available
• In addition to visual diagnostics, units provide an acoustic alert if surge protection is lost.
• Equipped with dry contact relays for remote monitoring.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449 & 1283#E146315
CSA#LR-94773
Wired-In Surge Protective Modules51015, 51020 & 51240 Series - For Industrial Environments & OEM Applications
10 YEAR LIMITED
51015, 51020 & 51240 Series
17
51015, 51020 & 51240 Series
6.90 (175.3mm)
7.50 (190.5mm)
4.38
(11
1.3m
m)
2.71 (68.8mm
)
1.25 (31.8 mm
) 1.25 (31.8 m
m)
6.90 (175.3 mm)
2.91
(73
.9 m
m)
REF
REF
3.47
3.47
REFREF6.126.12
REFREF
1.851.85
REF
REF
2.70
2.70
51020 & 51240 SERIES
51020-DIN
50120-WMT
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES51005 & 51010 SERIES
• Staged multi-component surge suppression circuitry provides clamping envelope that follows AC sine wave contour.
• DIN rail mounting versions available– Cat# 51005-DIN and 51010-DIN.
• 5& 10 Amp Circuit Current Capacity
• Equipped with dry relay contacts forremote monitoring.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449 & 1283#E146315
CSA#LR-94773
Wired-In Surge Protective Modules51005 & 51010 Series - For Industrial Environments & OEM Applications
10 YEAR LIMITED
18
DESCRIPTION CATALOG NO. RATING
Single-Phase, 3-Wire 51005-WM 120V AC 5A Single-Phase, 3-Wire 51010-WM 120V AC 10A Single-Phase, 3-Wire, DIN-Rail Mounting 51005-DIN 120V AC 5A Single-Phase, 3-Wire, DIN-Rail Mounting 51010-DIN 120V AC 10A
CATALOG NO. MCOV UL 1449 (Second Ed.) IMPULSE 6kV/500A MAX. SURGE CURRENT NOISE REJECTION(Test w/ 8x20us wave)
51005-WM 150V AC L-N:400V L-G: 400V N-G: 400V L-N: 26kA 20-40 dB(@ 10kHz-100MHz)
51010-WM 150V AC L-N:400V L-G: 400V N-G: 400V L-N: 26kA 20-40 dB(@ 10kHz-100MHz)
51005-DIN 150V AC L-N:400V L-G: 400V N-G: 400V L-N: 26kA 20-40 dB(@ 10kHz-100MHz)
51010-DIN 150V AC L-N:400V L-G: 400V N-G: 400V L-N: 26kA 20-40 dB(@ 10kHz-100MHz)
51005 & 51010 Series
51005 & 51010 Series
51005-DIN
1.60
(40
.1 m
m)
5.00 (127.0 mm)
2.50 (63.5 mm)
51005 & 51010 SERIES
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CLAMPING 3800 3840PERFORMANCE
UL Standard 1449 L-N: 500V Peak L-N: 330V Peakpermanently-wired test L-G: 500V Peak L-G: 400V Peak(8x20μs, 3000A) N-G: 500V Peak N-G: 330V Peak
DESCRIPTION CATALOG NO. RATING
For DIN-Rail Mounting, w/ Terminal Block 3800-DIN 120V ACTerminal Block 3800-0WM 120V ACPigtail Wire Leads, 6” Long 3800-OEM 120V ACFor DIN-Rail Mounting, w/ Terminal Block 3812-DIN 12V DCTerminal Block 3812-0WM 12V DCPigtail Wire Leads, 6” Long 3812-OEM 12V DCFor DIN-Rail Mounting, with Terminal Block 3824-DIN 24V DCTerminal Block 3824-0WM 24V DCPigtail Wire Leads, 6” Long 3824-OEM 24V DCFor DIN-Rail Mounting, with Terminal Block 3840-DIN 240V ACTerminal Block 3840-0WM 240V ACPigtail Wire Leads, 6” Long 3840-OEM 240V ACFor DIN-Rail Mounting, with Terminal Block 3848-DIN 48V DCTerminal Block 3848-0WM 48V DCPigtail Wire Leads, 6” Long 3848-OEM 48V DC
SPECIFICATIONS & FEATURES3800 SERIES
• MOV-based suppression circuitry provides optimum clamping.
• Provides Normal Mode protection for line-to-neutral,& common mode;line-to-ground, & neutral-to-ground
• Noise rejection@ 5kHz-5MHz: -35db
• Rated single-pulse transient energy (10x100μs, impulse): 280 Joules
• 3800-DIN, 3800-OWM: Terminal block accepts 22 AWG to 12 AWG conductors
• Consult factory on additional ratings on 3812, 3824, 3840 & 3848.
ENVIRONMENTALSTORAGE TEMPERATURE
-20�C to 85�COPERATING TEMPERATURE
-10�C to 60�C
ELECTRICAL3800: 120V AC (VRMS); 135V (MCOV)3840: 240V AC (VRMS); 250V (MCOV)
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL1449 CSAE146315 / DC-E175161 #LR-94773
Equipment Cabinet SPD’s3800 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
3800 Series
19
PERFORMANCE 3800 3840SPECIFICATION
Max. Single-Pulse L-N: 1300A L-N: 1300ATransient Current L-G: 6500A L-G: 6500A(8x20μs, Impulse) N-G: 6500A N-G: 6500A
LIGHT ONSURGE
PROTECTED
LIGHT ONSURGE
PROTECTED
LIGHT ONSURGE
PROTECTED
1.66 (42.16mm)
0.83(21.08mm)
2.69
(68
.33m
m)
3.28
(83
.31m
m)
3.78
(96
.01m
m)
0.625(15.88mm)
TERMINAL BLOCK
1.41
(35
.81m
m)
NOTE: WIRES ENTER
FROM THIS SIDE
0.73(18.54mm)
0.85 (21.59mm)
DIN RAIL CLIP
0.83
Ref
(21.
0 m
m)
1.66
Ref
(42.
1 m
m)
3.25
± 1
/4"
Ref
(82
.5 m
m)
0.85
Ref
(21.
59 m
m)
2.69 Ref (68.3 mm)
6.00 ± 1/2" Ref (152.4 mm)
3.78 Ref (96.0 mm)
3.28 Ref (83.3 mm)
BLACK WIREGREEN WIREWHITE WIRE
GREEN INDICATOR
NOTE: ALL DIMENSIONS ARE FOR REFERENCE ONLYREFER TO PART DRAWINGS FOR SPECIFICATIONS
NOTE: ALL DIMENSIONS ARE FOR REFERENCE ONLYREFER TO PART DRAWINGS FOR SPECIFICATIONS
NOTE: ALL DIMENSIONS ARE FOR REFERENCE ONLYREFER TO PART DRAWINGS FOR SPECIFICATIONS
L1 N G L2
L1 N G L2
L1 N G L2
TERMINALSCREWS (4)
TERMINAL CONNECTIONSACCEPTS #22
TO 12 AWG WIRE
PRODUCT SILKSCREEN
GREEN LED
MOUNTING TABS.ONE ON BOTH SIDES,SPACED 2.90(73.7mm)
INCHES APART
1.00
(25.4mm
)
2.99
(75.9mm)2.49(63.2mm)
SIDE VIEW
DIN CLIP
3800-OEM 3800-DIN 3840-DIN
3800-DIN
3800-OEM
3840-DIN
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
3803-485
DESCRIPTION CATALOG NO. RATING APPLICATIONCONNECTOR/MOUNTING
3-Pin Header Connector, Surface Mount 3803-DHP 9.6V DC For programmable logic devices & other computer-related data network products operating on “Blue Hose” networks
6-Pin Header Connector, Surface Mount 3803-485* 9.6V DC For programmable logic devices & other computer-related data network products operating on Allen-Bradley DH-485 data networks
5-Pin Header Connector, 3803-SPX 13.6V DC For products operating on SERIPLEX control bus networksSurface &DIN-Rail MountDB-9 Connector, Surface & DIN-Rail Mount 3803-CAN 25V DC For products operating on Honeywell control bus3-Pin Header Connector, Surface Mount 3803-MOD 9.6V DC For products operating on Modbus and Modbus Plus networks3-Pin Header Connector, Surface Mount 3420-009* 9.6V DC For products operating on 4-20ma Signal Loop networks, 9V DC3-Pin Header Connector , Surface Mount 3420-035* 38.5V DC For products operating on 4-20ma Signal Loop networks, 35V DCRJ-45 Cat. 5e Connector, 3860-CT5† 19.5V DC For products operating on Cat.5 (100 Base T) Surface & DIN-Rail Mount Ethernet PLC Ports and Cat.5 networks4-PositionTerminal Block 3860-GEF 100V DC For products operating on GE Fanuc Control Bus networks Surface &DIN-Rail MountRJ-45 Connector, Surface & DIN-Rail Mount 3861-ETH 19.8V DC For products operating on Ethernet PLC ports and CAT 3 networks BNC Connector, Surface & DIN-Rail Mount 3862-CON 9.18V DC For ControlNet networks and CCTV5-Pin Header Connector 3863-DEV 19.8V DC For DeviceNet networks Surface &DIN-Rail Mount
SPECIFICATIONS & FEATURES3400 & 3800 SERIES
• Designed for mounting in standard equipment cabinets.
• For use on Allen Bradley & “Blue Hose” devices
• Two options for ground connection
• Low clamping voltage
• Withstands surges at programmable logic devices in harsh electromag-netic or geographic areas.
• Provide transient voltage surge suppression for a selection of pro-grammable logic devices & other computer-related data network products.
ENVIRONMENTALSTORAGE TEMPERATURE
3803-DHP, 3803-485, 3803-MOD, 3420-009, 3420-035
-40�C to 90�C3803-SPX, 3803-CAN, 3860 Series
-20�C to 85�C
OPERATING TEMPERATURE3803-DHP, 3803-485, 3803-MOD, 3420-009, 3420-035
-40�C to 60�C3803-SPX, 3803-CAN, 3860 Series
-10�C to 85�C
STANDARDS & CERTIFICATIONSANSI/IEEE UL 497B
C-62.41 E175161CSA CE
#LR-94773 Approved
Low-Voltage Protection Modules3400 & 3800 Series - For Factory Automation & Industrial Control
10 YEAR LIMITED
20
3803-DHP
3 Pin TerminalConnectors (2)(Included)
3 Pin Headers (2)
BraidedGroundWire
1.51
(38.3 mm) Ref
2.26 (57.4 mm) Ref
6.00 (152.4 mm) Ref
0.65
(16.5 mm)
.79
Ref
Brass TerminalPlate ConnectedTo Ground
*The Rockwell Automation Encompass Program references complementary products from third party manufacturers committed to providing quality products and services that enhance the RockwellAutomation Solution products and solve the industrial automation needs of mutual customers.†Consult factory for availability.
3803-SPX
(152.4 mm)6"
(76.2 mm)3.00
(63.2 mm
)2.49
(43.2 mm)
1.70
ACCEPTS #8 STUDMOUNTING FOOT (2)
"G" TYPE RAILS.STANDARD AND 32mmCLIP. FITS 35mmDIN RAIL ADAPTOR
ACCEPTS 1/4" STUD.GROUND TAB
WITH 1/4" CRIMP LUGBRAIDED GROUND WIRE
INPUT OUTPUT5 PIN PLUGGABLE CONNECTORS
3400 & 3800 Series
3803-SPX
3680-CT5
DIN-RAILMOUNTING
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
3863-DEV
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADECOLOR SURGE,DUPLEX IG,SURGE,DUPLEX IG,SURGE,SINGLE SURGE,DUPLEX IG, SURGE,DUPLEX SURGE,DUPLEX IG,SURGE,DUPLEX
Indicator Light, Indicator Light, Indicator Light, Indicator Light, Indicator Light, Indicator Light Indicator LightAudible Alarm Audible Alarm Audible Alarm Audible Alarm Audible Alarm
Brown 8280 – – 7280 7280-IG 5280 5280-IGIvory 8280-I 8280-IGI 8281-IGI 7280-I 7280-IGI 5280-I 5280-IGIWhite 8280-W 8280-IGW 8281-IGW 7280-W 7280-IGW 5280-W 5280-IGWGray – 8280-IGG – 7280-GY 7280-IGG 5280-GY 5280-IGGRed 8280-R – – – – – –Blue 8280-B 8280-IGB – 7280-B 7280-IGB 5280-B 5280-IGBOrange – 8280-IGO 8281-IGO – 7280-IGO – 5280-IGOAlmond 8280-A – – 7280-A – 5280-A –
SPECIFICATIONS & FEATURES3880, 5280, 5380, 7280, 7380,
8280, 8281, 8380 & 8381 SERIES
• Real time diagnostics via indicator light.
• Available with audible alarm.
• Back and Side-Wired
• Isolated ground versions
• DIN-Rail mountable (model 3880)
ELECTRICAL
DIELECTRIC VOLTAGEWithstands 2000V per UL 498
CURRENT INTERRUPTERFull Rated Current
TEMPERATURE RISEMax 30�C after 250 cycles of overload
at 200% of rated current
ENVIRONMENTAL
OPERATING TEMPERATURE -40�C to 60�C
FLAMMABILITYRated V-2 per UL 94
STANDARDS & CERTIFICATIONSNEMA WD-6 & ANSI C-73
Certified
CSA - C22.2 No.42#152105
NOM#057
UL498HG#E13399
Wired-In Receptacles5280, 7280, 8280 & 8281 Series
10 YEAR LIMITED
21
8380 8280-IGO 8281-IGI
52808380-IGB 7280-W
15A 125V NEMA 5-15R
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
FACE INDUSTRIAL GRADECOLOR IG,SURGE,DUPLEX
Indicator Light
Brown 5380-IGIvory 5380-IGIWhite 5380-IGWGray 5380-IGGBlue 5380-IGBOrange 5380-IGO
HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADE INDUSTRIAL GRADEFACE SURGE,DUPLEX IG,SURGE,SINGLE IG,SURGE,SINGLE IG,SURGE,SINGLE SURGE,DUPLEX IG,SURGE,DUPLEX SURGE,DUPLEX
COLOR Indicator Light, Indicator Light, Indicator Light, Indicator Light, Indicator Light, Indicator Light, Indicator LightAudible Alarm Audible Alarm Audible Alarm Audible Alarm Audible Alarm Audible Alarm
Brown 8380 8381 – – 7380 7380-IG 5380Ivory 8380-I 8381-I 8380-IGI 8381-IGI 7380-I 7380-IGI 5380-IWhite 8380-W – 8380-IGW 8381-IGW 7380-W 7380-IGW 5380-WGray 8380-GY 8381-GY 8380-IGG – 7380-GY 7380-IGG 5380-GYRed 8380-R – 8380-IGR – – – –Blue 8380-B – 8380-IGB 8381-IGB 7380-B 7380-IGB 5380-BOrange – – 8380-IGO 8381-IGO – 7380-IGO –
Wired-In Receptacles5380, 7380, 8380 & 8381 Series
10 YEAR LIMITED
22
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX. SURGE CURRENT NOISE REJECTIONIMPULSE 6kV/500A (test w/ 8x20us wave)
All Single or IG Models 720 L-N: 400V L-N: 24kA -30 dB @ 500kHz-30MHz
1.47 (37.3 mm)
2.70
(68
.6 m
m)
3.81
(96
.8 m
m)
3.28
(83
.3 m
m)
1.70 (43.2 mm)
Surge Receptacles
20A 125V NEMA 5-20R
20A 125V NEMA 5-20R
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES5480,5490,8480 & 8490 SERIES
• Four-In-One Surge Receptacles.
• Hospital Grade and Industrial Grade.
• Isolated Ground available.
ELECTRICALDIELECTRIC VOLTAGE
Withstands 2000V per UL 498CURRENT INTERRUPTER
Full Rated CurrentTEMPERATURE RISE
Max 30�C after 250 cycles of overloadat 200% of rated current
ENVIRONMENTAL
OPERATING TEMPERATURE -40�C to 60�C
FLAMMABILITYRated V-2 per UL 94
STANDARDS & CERTIFICATIONSNEMA WD-6 & ANSI C-73
CertifiedCSA - C22.2 No.42
#152105
NOM#057
UL498HG#E13399
UL498#E13399
Wired-In Receptacles5480, 5490, 8480 & 8490 Series - Four-In-One
10 YEAR LIMITED
23
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX. SURGE CURRENT NOISE REJECTIONIMPULSE 6kV/500A (test w/ 8x20us wave)
All Units 720 L-N: 330V L-N: 24kA -30 dB @ 500kHz-30MHzL-G: 400VN-G: 400V
FACE INDUSTRIAL GRADE INDUSTRIAL GRADE HOSPITAL GRADE HOSPITAL GRADECOLOR SURGE IG, SURGE IG, SURGE IG, SURGE
Indicator Light Indicator Light Indicator Light Indicator Light
Ivory 5480-I – 8480-I –White 5480-W – 8480-W 8480-IGWGray 5480-GY – – –Red 5480-R – 8480-R –Orange – 5480-IG – 8480-IGBlue 5480-BU – – 8480-IGB
Ivory 5490-I – 8490-I 8490-IGIWhite 5490-W – 8490-W –Gray 5490-GY – – –Red – – 8490-R –Orange – 5490-IG – –Blue 5490-BU – – 8490-IGB
15A 125V, NEMA 5-15R, 2-P 3-W, Grounding
20A 125V, NEMA 5-20R, 2-P 3-W, Grounding
8490-IGG 8490-R
5490-BU 5480-IGI
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
PLATE ADAPTERCOLOR PLATE
Brown 3254Ivory 3254-IWhite 3254-WGray 3254-GYRed 3254-RBlack 3254-EOrange 3254-OBlue 3254-BLU
Wired-In Receptacles5480, 5490, 8480 & 8490 Series - Four-In-One
10 YEAR LIMITED
24
Four-In-One Adapter Plates Four-In-One Portable Boxes
BOX PORTABLECOLOR BOX
Ivory 4254-IGray 4254-GYBlack 4254-EOrange 4254-OBlue 4254-BLUYellow 4254-Y
Accepts #16/3 AWG Type SJ to #12/3 AWGType SO COPPER Only.
Portable boxes are not UL Listed.
Single-Gang
4.80 (121.9 mm) square
2.75 (69.8 mm)
3.38 (85.9 mm
1.75 (44.4 mm)
1.73 (43.9 mm)
0.31(7.9 mm)
0.42 (10.7 mm)
0.12 (3.2 mm)
3.28
(83
.4 m
m)
3.38
(85
.9 m
m)
2.73
(69
.3 m
m)
4.25
(10
7.9
mm
)
4.50 (114.3 mm) square
3.38 (85.9 mm) square
3.28
(83
.3 m
m)
squ
are
4 knockouts
.90(22.9 mm)
0.66(16.8)
Feed Thru Wire Hole
4.50 (114.3 mm) square
3.38 (85.9 mm) 0.68 (17.1 mm)
0.25 (6.4 mm)
3.38
(85
.9 m
m)
1.15 (29.2mm)
Mounts Directly
4” Octagon 4” Square 2-Gang
Mounts with Adapter Plate
411/16” Square
Four-In-One Receptacles
3254-E 4254-Y
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES3880-DIN, 3801-DIN
• Ideal for mounting in equipmentcabinets where convenient plug-in surge protection is desired.
• Provides MOV-Based Normal Modeand Common Mode L-N, L-G, N-G protection
• Hospital Grade Receptacles ensure the best electrical connection of equipment
• Designed for use on 120V single-phase AC power sources
• Green LED goes off when surge protection is lost
• Audible alarm has an integral disable (quiet) switch
• Power continues to be provided to connected loads in the event of protection loss
• Module housing comes in black only
ENVIRONMENTAL
STORAGE TEMPERATURE -20�C to 85�C
OPERATING TEMPERATURE -10�C to 60�C
MECHANICALTerminal Block accepts #22-#12 AWG
conductors.
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45UL1449 CSAE146315 #LR-94773
50, 60Hz 120V 150V rms 24kA (L-N),12kA (L-G), 320 Joules -35 dB12kA (N-G)
UL1449 SUPPRESSED VOLTAGE RATINGS (SVR) Assigned at 6" lead length with 6kV/500A impulse in accordance with UL1449 (2nd Ed.)
400/400/400Vpk
CATALOG NO. RATED LINE VOLTAGE DESCRIPTION
3880-DIN 120V Line Voltage Hospital Grade Surge Protected Duplex Outlet w/ LED & Audible Alarm
3801-DIN 120V Line Voltage Surge Protected Single Convenience Receptacle
8598-DIN 120V Line Voltage GFCI Protected SmartLock® Duplex w/ LED, Non-Surge
16252-DIN 120V Line Voltage Duplex Receptacle, Non-Surge
DIN-Rail Mountable Receptacles3880-DIN,3801-DIN, 8598-DIN & 16252-DIN
10 YEAR LIMITED
25
DIN-Rail Mountable Surge Protection Receptacles
OPERATING RATED MAXIMUM MAXIMUM RATED EMI-RFI NOISEFREQUENCY LINE VOLTAGE CONTINUOUS SINGLE-PULSE SINGLE-PULSE REJECTION
OPERATING TRANSIENT CURRENT TRANSIENT ENERGY @ 50 OhmsVOLTAGE (MCOV) (8x20µs, Amps peak) (10x1000µs, Joules) 5kHz - 5MHz
3880-DIN & 3801-DIN Surge Performance Data
Surge Clamping Performance
TOP VIEW
BACK VIEW
3880-DIN
3801-DIN
8598-DIN(Non-Surge)
16252-DIN(Non-Surge)
6.22
(15
8 m
m)
5.05
(12
8.2
mm
)
5.63
(14
3 m
m)
5.05
(12
8.2
mm
)
5.63
(14
3 m
m)
5.05
(12
8.2
mm
)
2.73 (69.3 mm)
1.09 (27.7 m
m)
2.23 (56.6 mm
)
2.8 (71.1 mm)
2.73 (69.3 mm)
2.60 (66 mm)
2.60 (66 mm)
2.73 (69.3 mm)
2.60 (66 mm)
2.54 (64.5 mm)
1.99
(5
0.5
mm
)
8598-DIN 3880-DIN 16252-DIN 3801-DIN
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION MODEL NO. COLOR PROTECTION MODULE
Electronic Grade 5950-PSG Gray 2-Blankfor all electronic equipment, w/ 71/2 Foot Cord 5950-0PS Beige 2-Blankwith Right Angle Plug
Home Office Grade 5950-0ST Beige 1-Blank, 1-Telephonewith protection for Phone / Fax / Modem, 5950-STG Gray (1-Line In, 2-Line Out)w/ 71/2 Foot Cord with Right Angle Plug
Electronic Grade 5950-SCG Gray 1-Blank, 1-Coaxwith protection for CATV and DSS Coax Lines, (2-Pairs In, Out F Connectors)w/ 71/2 Foot Cord with Right Angle Plug
Satellite System Grade 5950-SSG Gray 1-Telephone (1-Line In, 2-Line Out)with protection for Phone / Fax / Modem and CATV 1-Coax (2-Pairs In, Out F Connectors)or DSS Coax Lines, w/ 71/2 Foot Cord withRight Angle Plug
SPECIFICATIONS & FEATURES5950 SERIES
• Expandable modular design with 2 slots accepts a variety of interchangeable plug-in modules to accommodate surge protection requirements as equipment changes.
• Easy-to-use with 6 standard and 3 transformer-pad surge protected AC outlets.
• Diagnostic indicators for Power, protection, Polarity & Ground.
ELECTRICALWith 6 Standard & 3 Transformer-Pad
Surge Protected Outlets, Rated 15A 120V AC
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449#E146315
CSA#LR-94773
26
CATALOG NO. JOULES UL 1449 (Second Ed.) MAX. SURGE CURRENT NOISE REJECTIONIMPULSE 6kV/500A (Test w/ 8x20us wave) (@100kMz-30MHz)
All Units 1520 L-N:330V L-N: 92kA -5 to -40 dB
5950 Series
5950 Series
5950 Series
Modular Surge Protective Strips5950 Series - For Residential & Commercial LAN Environments
LEVITONLIFETIME LIMITED DOWNLINE
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CATALOG NO. MCOV CLAMPING VOLTAGE TESTED TO(VDC) (VDC) SPECIFICATIONS OF:
5951 60 388 UL 4525952 16.6 23 UL 497B5953 60 388 UL 4525954 288 715 UL 497A5955 205 210 UL 497A5957 16.6 23 UL 497B5958 288 715 UL 497A5959 288 715 UL 497A
SPECIFICATIONS & FEATURES5951, 5952, 5953, 5954
5955, 5957, 5958 & 5959 SERIES
• Interchangeable plug-in modules for use in the 5950 TVSS strip to accommodate surge protectionrequirements as equipment changes.
• Convenient removal and installation.
• Multiple colors to coordinate with 5950 strip.
STANDARDS & CERTIFICATIONSANSI/IEEE
C-62.36
UL497AUL497BUL452
#E146315
CSA#LR-94773
Plug-In Modules5951, 5952, 5953, 5954, 5955, 5957, 5958 & 5959 Series
LEVITONLIFETIME LIMITED DOWNLINE
27
DESCRIPTION MODEL NO. COLOR
Coax and Satellite Module 5951-0SA Beige Two pairs of In /Out F Connectors for Satellite and Cable TV Systems 5951-SAT GrayEthernet Module 5952-0ET BeigeTwo RJ45 Connectors with Ground Pin for Ethernet - Cat. 3 5952-ETH GrayCoax Module 5953-0PC BeigeOne Pair of In/Out F Connectors for Cable TV Systems 5953-PCG Gray
Telephone Module 5954-AT4 Beige One Input, Two Output Connectors for Phone / Fax / Modem, Also Acts as a Splitter 5954-PT4 Gray
DSL/ADSL Module 5955-0DT Beige One Input, Two Output Connectors for DSL /ADSL Line, Also Acts as a Splitter 5955-DTG GrayCat. 5 Ethernet Module 5957-OC5 Beige Two RJ45 Connectors with Ground Pin for Ethernet - Cat. 5 5957-C5G Gray
Two Line Telephone Module 5958-AT4 Beige One Input, One Output RJ11 Connector for 4-Wire POTS 5958-PT4 Gray
Four Line Telephone Module 5959-BT8 Beige One Input, One Output RJ45 Connector for 8-Wire POTS 5959-GT8 Gray
5951, 5952, 5953, 5954, 5955, 5957, 5958 & 5959 Series
5951, 5952, 5953, 5954, 5955, 5957, 5958 & 5959 Series
5953-PCG
5951-SAT
5954-AT4
(Consult factory for availability.)
3950-BKTwith a 5953-PCG
For use with Leviton structured media panels.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES5300 SERIES
• Clamping profile tightly tracks AC sine wave.
• Six protected outlets with ON/OFF switch.
• Resettable circuit breaker andinternal fusing.
5300-HTS
• Tamper-proof, Hospital Grade receptacles
• Leakage current below UL544 100VA limits
ENVIRONMENTAL
STORAGE TEMPERATURE-35�C to 60�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449, 1363, 1283#E146315
CSA#LR-94773
Six-Outlet Plug Strips5300 Series - 15A 120V AC Plug-In Devices
LEVITONLIFETIME LIMITED DOWNLINE
28
5300 Series
DESCRIPTION CATALOG NO. APPLICATION HOUSING COLOR
6-Outlet w/ Switch, w/ 6’ Cord 5300-PS Data-Sensitive Operations Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GS Data-Sensitive Operations Thermoplastic Gray6-Outlet w/ Switch, w/ 15’ Cord 5300-S15 Data-Sensitive Operations Thermoplastic Beige6-Outlet w/ Switch, w/ 15’ Cord 5300-G15 Data-Sensitive Operations Thermoplastic Gray6-Outlet w/ Switch, w/ 6’ Cord 5300-PST Telephone/Modem Line Protection Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GST Telephone/Modem Line Protection Thermoplastic Gray6-Outlet w/ Switch, w/ 6’ Cord 5300-PSC CATV Line Surge Protection Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GSC CATV Line Surge Protection Thermoplastic Gray6-HG, Tamper-Resistant Receptacles, 5300-HTS Continues to supply power to load Aluminum Beigew/o Switch, 6’ Cord Transparent Plug if protection is lost
6-HG, Tamper-Resistant Receptacles 5300-H15 Continues to supply power to load Aluminum Beigew/o Switch, 15’ Cord Transparent Plug if protection is lost
6-Outlet w/ ON/OFF Switch, w/ 6’ Cord 5300-IPS If protection is lost, surge strip does not Aluminum Beigecontinue to supply power to the load
5300 Series
5300-PSC5300-HTS
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTION LOW VOLTAGE CLAMPINGIMPULSE 6kV/500A (test w/ 8x20us wave) (@100kHz-100MHZ) (UL 497A/B or UL 452)
5300-PS 1620 L-N: 330V L-N: 48KA -20 to -40 dB –
5300-GS 1620 L-N: 330V L-N: 48kA -20 to -40 dB –
5300-S15 1620 L-N: 330V L-N: 48kA -20 to -40 dB –
5300-G15 1620 L-N: 330V L-N: 48kA -20 to -40 dB –
5300-PST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V
5300-GST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V
5300-PSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB –
5300-GSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB –
5300-HTS 1080 L-N: 400V L-N: 36kA -20 to -40 dB –
5300-H15 1080 L-N: 400V L-N: 36kA -20 to -40 dB –
5300-IPS 1440 L-N: 330V L-N: 27kA -20 to -40 dB –
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION CATALOG NO. APPLICATION HOUSING COLOR
6-Outlet, General Duty, 15A 120V, w/ 6 Foot Cord 5100-PS Compatible w/ UPS and SPS Systems Thermoplastic Beige6-Outlet, General Duty, 15A 120V, w/ 6 Foot Cord 5100-GS Compatible w/ UPS and SPS Systems Thermoplastic Gray6-Outlet, General Duty, 15A 120V, w/ 15 Foot Cord 5100-S15 Compatible w/ UPS and SPS Systems Thermoplastic Beige6-Outlet, General Duty, 15A 120V, w/ 15 Foot Cord 5100-G15 Compatible w/ UPS and SPS Systems Thermoplastic Gray6-Outlet, General Duty, 15A 120V, w/ 6 Foot Cord 5100-IPS For Rough Environments Aluminum Beige6-Outlet, General Duty, 20A 120V, w/ 6 Foot Cord 5100-IS2 For Rough Environments Aluminum GrayHeavy Duty, 6-Outlet w/ ON/OFF Switch, w/ 6 Foot Cord 5200-PS For Micro Processor Based Equipment Thermoplastic BeigeHeavy Duty, 6-Outlet w/ ON/OFF Switch, w/ 6 Foot Cord 5200-GS For Micro Processor Based Equipment Thermoplastic BeigeHeavy Duty, 6-Outlet w/ ON/OFF Switch, w/ 15 Foot Cord 5200-S15 For Micro Processor Based Equipment Thermoplastic BeigeHeavy Duty, 6-Outlet w/ ON/OFF Switch, w/ 15 Foot Cord 5200-G15 For Micro Processor Based Equipment Thermoplastic Gray
SPECIFICATIONS & FEATURES5100 & 5200 SERIES
• All mode protection with clamping profile that tightly tracks AC sine wave.
• Resettable circuit breaker and internal fusing.
ENVIRONMENTAL
STORAGE TEMPERATURE For 5100-PS, 5200-PS,5100-IPS & 5200-IPS
-35�C to 60�C
OPERATING TEMPERATUREFor 5100-PS & 5200-PS
0�C to 40�C5100-IPS & 5200-IPS
-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449, 1363, 1283#E146315
CSA#LR-94773
Six-Outlet Plug Strips5100 & 5200 Series - 15A 120V AC & 20A 120V AC Plug-In Devices
LEVITONLIFETIME LIMITED DOWNLINE
29
5100 & 5200 Series
5100 & 5200 Series
5200-PS5100-IPS
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTIONIMPULSE 6kV/500A (test w/ 8x20us wave) (@100kHz-100MHZ)
5100-PS 720 L-N: 330V L-N: 24kA& -10 to -20 dB
5100-GS 720 L-N: 330V L-N: 24kA -10 to -20 dB
5100-S15 720 L-N: 330V L-N: 24kA -10 to -20 dB
5100-G15 720 L-N: 330V L-N: 24kA -10 to -20 dB
5100-IPS 720 L-N: 330V L-N: 24kA -10 to -20 dB
5100-IS2 720 L-N: 330V L-N: 24kA -10 to -20 dB
5200-PS 900 L-N: 330V L-N: 24kA -10 to -20 dB
5200-GS 900 L-N: 330V L-N: 24kA -10 to -20 dB
5200-S15 900 L-N: 330V L-N: 24kA -10 to -20 dB
5200-G15 900 L-N: 330V L-N: 24kA -10 to -20 dB
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTION LOW VOLTAGE CLAMPINGIMPULSE 6kV/500A (test w/ 8x20us wave) (UL 497A/B or UL 452)
4800-PS 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) –
4800-S15 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) –
4800-PSN 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) –
3500-P 540 L-N: 400V L-N: 12kA -40 dB (150kHz to 20MHz) –
3500-PT 540 L-N: 400V L-N: 12kA -40 dB (150kHz to 20MHz) –
3500-PC 540 L-N: 400V L-N: 12kA -40 dB (150kHz- to 20MHz) –
4900-PS 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) –
4900-PSC 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) –
4900-PST 540 L-N: 400V L-N: 12kA -5 to -40 dB (100kHz to 30MHz) 265V
4900-P 540 L-N: 330V L-N: 12kA -40 dB (150kHz to 20MHz) –
4900-PT 540 L-N: 330V L-N: 12kA -40 dB (150kHz to 20MHz) –
4900-PC 540 L-N: 330V L-N: 12kA -40 dB (150kHz to 20MHz) –
3500, 4800 & 4900 Series
SPECIFICATIONS & FEATURES3500, 4800 & 4900 SERIES
• Provides all mode protection for all outlets.
• LED indicates protection is active.
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449#E146315
CSA#LR-94773
Plug Strips & Plug-Ins3500, 4800 & 4900 Series - 15A 120V AC & 15A 125V AC Plug-In Devices
LEVITONLIFETIME LIMITED DOWNLINE
30
DESCRIPTION CATALOG NO. APPLICATION
6-Outlet Plug Strip, w/ 6’ Cord 4800-PS All-Purpose6-Outlet Plug Strip, w/ 15’ Cord 4800-S15 All-Purpose6-Outlet Plug Strip, w/ 6’ Cord, No Switch 4800-PSN All-Purpose6-Outlet Surge Adapter, Beige 3500-P Noise Attenuation for Micro-Processor Driven Equipment6-Outlet Surge Adapter, w/ 2 RJ11 Phone Jacks 3500-PT Noise Attenuation for Micro-Processor Driven Equipment6-Outlet Surge Adapter, w/ 2F Coax Cable Connectors 3500-PC Noise Attenuation for Micro-Processor Driven Equipment6-Outlet Plug Strip, w/ 2 RJ11Phone Jacks 4900-PST Multi-Stage Protection6-Outlet Surge Adapter, Beige 4900-P Noise Attenuation for Micro-Processor Driven Equipment6-Outlet Surge Adapter, w/ 2 RJ11 Phone Jacks 4900-PT Noise Attenuation for Micro-Processor Driven Equipment6-Outlet Surge Adapter, w/ 2F Coax Cable Connectors 4900-PC Noise Attenuation for Micro-Processor Driven Equipment
3500, 4800 & 4900 Series
4800-PS
4900-PC 3500-PT 3500-PC
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION CATALOG NO. APPLICATION
7-Outlet Strip, Beige w/ 6 Foot Cord 4950-PS Micro-Processor Driven Electronic Equipment7-Outlet Strip, w/ 15 Foot Cord, Beige 4950-S15 Micro-Processor Driven Electronic Equipment7-Outlet Strip, w/ 2 RJ11 Phone Jacks, Beige, w/ 6 Foot Cord 4950-PST Micro-Processor Driven Electronic Equipment7-Outlet Strip, w/ 2F Coax Cable Connectors, Beige, 4950-PSC Micro-Processor Driven Electronic Equipmentw/ 6 Foot CordHeavy Duty, 4-Outlet, Beige 5100-P PC’s & Peripherals, Electronic Cash Registers, Digital
Sound Systems, Video Equipment, and Microwave OvensMax. Protection, 4-Outlet, Gray 5300-GP Point of Sale Systems, PC’s & Peripherals, Copy Machines, Max. Protection, 4-Outlet, Beige 5300-P Computer Controlled Office Equipment., and Microwave Ovens
5100-P
4950, 5100 & 5300 Series
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTION LOW VOLTAGE CLAMPINGIMPULSE 6kV/500A (test w/ 8x20us wave) (@ 5kHz-5MHz) (UL 497A/B or UL 452)
5300-PS 1620 L-N: 330V L-N: 48KA 20-40 dB –
4950-PS 1140 L-N: 330V L-N: 24kA -40 to -50 dB –
4950-S15 1140 L-N: 330V L-N: 24kA -40 to -50 dB 35V
4950-PST 1140 L-N: 330V L-N: 24kA -40 to -50 dB 425V
4950-PSC 1140 L-N: 330V L-N: 24kA -40 to -50 dB 35V
5100-P 720 L-N: 330V L-N: 24kA -10 to -20 dB @ –500kHz-100MHz
5300-P 1620 L-N: 330V L-N: 48kA -30 to -60 dB @ –5kHz-100MHz
SPECIFICATIONS & FEATURES4950 SERIES
• Hybrid design combines surge protection circuitry with advanced noise filtration components.
• Real time diagnostics with LEDindicators monitor power and protection status.
5100 & 5300 SERIES
• Connect directly to standard NEMA5-15 receptacles.
• Thermal fusing & overcurrent protection via resettable 15A breaker.
• Hi-frequency noise filtration.
ENVIRONMENTAL
STORAGE TEMPERATURE -35�C to 60�C
OPERATING TEMPERATURE-40�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449#E146315
CSA#LR-94773
Four-Outlet SPD’s & Plug Strips4950, 5100 & 5300 Series - 15A 120V 50, 60 Hz AC Plug-In Devices
LEVITONLIFETIME LIMITED DOWNLINE
31
4950, 5100 & 5300 Series
Power
Protection
Polarity & Ground
®
1.50(38.1 mm)
3.50 (88.9 mm)
5.8
5 (1
48.5
mm
)
5100 & 5300 SERIES 4950 SERIES
5300-GP
4950-PS
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES5500 SERIES
• Mounts on 19” equipment rack with six protected duplex receptacles – (5) in back, (1) in front.
• Available with or without rocker-style ON/OFF switch.
• Resettable circuit breaker protects against overloading and power-supply failure.
ENVIRONMENTAL
STORAGE TEMPERATURE -35�C to 60�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449Recognized Component
#E146315
CSA#LR-94773
Rack-Mount Devices5500 Series - For Industrial & Commercial Environments
LEVITONLIFETIME LIMITED DOWNLINE
32
CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTIONIMPULSE 6kV/500A (test w/ 8x20us wave) (@ 100kHz - 30MHz)
5300-PS 1620 L-N: 330 L-N: 48KA 20-40 dB –
5500-190 1440 L-N: 330V L-N: 27kA -5K to -40 dB
5505-190 540 L-N: 400V L-N: 10kA -5K to -40 dB
5500-15N 1440 L-N: 330V L-N: 27kA -5K to -40 dB
5500-NL 1440 L-N: 330V L-N: 27kA -5K to -40 dB
5500-192 1440 L-N: 330V L-N: 27kA -5K to -40 dB5500-20N 1440 L-N: 330V L-N: 27kA -5K to -40 dB5500-20L 1440 L-N: 330V L-N: 27kA -5K to -40 dB5500-2NL 1440 L-N: 330V L-N: 27kA -5K to -40 dB
DESCRIPTION CATALOG NO. RATING
19” Rack-Mount, SPD, w/ ON/OFF Switch, w/ 12 Foot Cord 5500-190 15A 120V19” Rack-Mount, SPD, w/ ON/OFF Switch, w/ 12 Foot Cord 5505-190 15A 120V19” Rack-Mount, SPD, No ON/OFF Switch, w/ 12 Foot Cord 5500-15N 15A 120V19” Rack-Mount, SPD, No ON/OFF Switch, w/ 12 Foot Cord 5500-NL 15A 120V19” Rack-Mount, SPD, w/ ON/OFF Switch, w/ 12 Foot Cord 5500-192 20A 120V19” Rack-Mount, SPD, No ON/OFF Switch, w/ 12 Foot Cord 5500-20N 20A 120V19” Rack-Mount, SPD, w/ ON/OFF Switch, w/ 12 Foot Cord 5500-20L 20A 120V19” Rack-Mount, SPD, No ON/OFF Switch, w/ 12 Foot Cord 5500-2NL 20A 120V
5500 Series
5500 Series
5500 SERIES
5500-190
5500-190
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
DESCRIPTION CATALOG NO. RATING
19” Rack-Mount Power Center, w/ 71/2 Foot Cord 4505-20L 20A 125V19” Rack-Mount Power Center, w/ 10 Foot Cord 4505-20T 20A 125V
DESCRIPTION CATALOG NO. RATING FEATURES MOUNTING
19” Power Pole, 2119D-L06 15A 120V 20A Circuit Breaker, Single Hole Brackets forw/ 15 Foot Cord 6 Grounded Outlets Twist-Lock Plug Vertical or Horizontal Mounting24” Power Pole, 1524D-R06 20A 120V 15A Circuit Breaker, Male & Female Brackets forw/ 15 Foot Cord 6 Grounded Outlets Right-Angle Plug Horizontal Mounting
SPECIFICATIONS & FEATURES4505 SERIES
• Mounts on 19” equipment racks with five duplex receptacles.
• No switch and 20 Amp twist-lock plug to prevent accidental power loss to connected equipment.
• LED to indicate power light is on.
• Provided 20 Amp circuit breaker.
2119D & 1524D SERIES
• Durable metal base.
• Resettable circuit breaker.
• Other lengths available – Ask your Sales Representative.
ENVIRONMENTAL
STORAGE TEMPERATURE -35�C to 60�C
OPERATING TEMPERATURE-10�C to 60�C
STANDARDS & CERTIFICATIONSANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449Recognized Component
#E146315
CSA#LR-94773
Rack-Mount Devices4505, 2119D, 1524D & KFL-A1398 Series - For Industrial & Commercial Environments
LEVITONLIFETIME LIMITED DOWNLINE
33
4505 Series
2119D & 1524D Series
4505 Series
4505 Series
1524D-R06
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
SPECIFICATIONS & FEATURES5350 SERIES
• For use in commercial and residential environments.
• Individual devices can be applied as needed
ENVIRONMENTAL
STORAGE TEMPERATURE -40�C to 85�C
OPERATING TEMPERATURE-40�C to 85�C
FLAMMABILITYPer UL 945-V
Flame Retardant Thermoplastic
STANDARDS & CERTIFICATIONSANSI/IEEE
C-62.36
UL 452UL 497A#E146315
CSA#LR-94773
Low-Voltage & Data Line SPD’s 5350 Series - Stand Alone
LEVITONLIFETIME LIMITED DOWNLINE
34
DESCRIPTION CATALOG NO. CONNECTOR APPLICATION
2-Wire Coax 5350-PC† F Connector CATV2-Wire Coax 5350-SAT† F Connector DSS Systems4-Wire Dial Up Lines 5350-PT4† RJ-11 4-Wire Telco8-Wire Dial Up Lines 5350-PT8† RJ-45 8-Wire Telco
5350 Series
CATALOG NO. NO. OF WIRES/PINS PROTECTED LINE VOLTAGE CLAMPING VOLTAGE(VDC) (VDC)
5350-PC 2/ (Center + Shield) 10 255350-SAT 2/ (Center + Shield) 25 355350-PT4 4/ (2, 3, 4 & 5) 48 2655350-PT8 8/ (1-8) 48 265
5350 Series
5350 Series
5350-PT4
5350-PC
5350-PT8
5350-SAT
®®Lin
e
1.23(31.2 mm) 3.50
(88.9 mm)
5.07(128.7 mm)
1.75
(44.
4 m
m)
®Lin
e
1.23(31.2 mm)
4.125(104.7 mm)
1.75
(44.
4 m
m)
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
MODEL U1000-ONL U2000-ONL U3000-ONL U1000-ORM U2000-ORM U3000-ORM
Capacity 1000VA 2000VA 3000VA 1000VA 2000VA 3000VA(0.7pf) 700W 1400W 2100W 700W 1400W 2100WVoltage 120V +/-27% single phase @ 50 or 60Hz (auto sensing)Voltage (or battery) 120V +/-2% @ 50 or 60Hz (auto sensing)Output Type Pure sine waveSurge Per IEEE C-62.41Overload Protection Automatic UPS shutdown if overload protection exceeds 105% of nominal for 60 sec; 130% for 3 secType Sealed maintenance-free lead acidRecharge Time 8 hrs. (90% capacity)Protection Automatic self-test and discharge protection. Battery replacement indicator.Battery Back-up Slow beeping soundBattery Low Rapid beeping soundOverload Continuous tone
CATALOG NO. COLOR DESCRIPTION NET WEIGHT (lbs.)
U1000-ONL Beige On-Line, Pure Sine Wave, Tower, 1000VA, 254-Outlets, Software
U2000-ONL Beige On-Line, Pure Sine Wave, Tower, 2000VA, 628-Outlets, Hard-Wire, Software
U3000-ONL Beige On-Line, Pure Sine Wave, Tower, 3000VA, 73.38-Outlets, Hard-Wire, Software
U1000-ORM Black On-Line, Pure Sine Wave, 3U Rack Mount, 42.31000VA, 4-Outlets, Software
U2000-ORM Black On-Line, Pure Sine Wave, 3U Rack Mount, 602000VA, 4-Outlets, Hard-Wire, Software
U3000-ORM Black On-Line, Pure Sine Wave, 3U Rack Mount, 663000VA, 8-Outlets, Hard-Wire, Software
SPECIFICATIONS & FEATURESLev-UPS™ ONLINE SERIES
• True On Line Double Conversion Topology with Input Power Factor Correction.
• Pure Sine Wave Output w/ less than 3% THD
• Lev-WARE power monitoring & UPS control software
• Surge protection & noise filtration.
• RS-232 & dry contact signaling.• 2 year product warranty – parts,
workmanship, and battery.(Optional extension to 5 years)
• $75,000 connected equipment warranty.
• UL 1778 & cUL listed, FCC compliant & ISO 9001 Certified.
Lev-UPS™ Online SeriesU1000-ONL, U2000-ONL, U3000-ONL, U1000-ORM, U2000-ORM & U3000-ORM
2 YEAR LIMITED
35
Lev-UPS™ Online Series
Input
Output
Protection &Filtering
Battery
Alarms
U3000-ONLU1000-ONL
U2000-ORM
U2000-ORM
Multi-Function LCDDisplay
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
LOAD U1000-ONL U2000-ONL U3000-ONL U1000-ORM U2000-ORM U3000-ORMVA/WATTS
250/175 54 97 105 49 74 99500/350 24 52 68 25 39 68750/125 16 36 51 18 29 481000-700 9 23 33 9 17 301250/875 – 15 25 – 13 231500/1050 – 12 21 – 10 201750/1225 – 10 18 – 8 172000/1400 – 8 17 – 7 152300/1610 – – 14 – – 122700/1890 – – 11 – – 103000/2100 – – 9 – – 7
Lev-UPS™ Online SeriesU1000-ONL, U2000-ONL, U3000-ONL, U1000-ORM, U2000-ORM & U3000-ORM
2 YEAR LIMITED
36
Applications
• Computers and Peripherals• High End Servers• Phone and Telecommunication Systems• Security and Banking Systems• Medical and Related Equipment• Commercial and Industrial Automation
• Lab, Test and Measurement Equipment• Internet Access Terminals• Lighting Controls• Entertainment• Process Control• Data Processing Equipment
Back-up Times (in minutes)
5.20
RE
F5.
20R
EF
EXT. BAT.EXT. BAT.
SELECTSELECT
REMOTEREMOTEPORTPORT
CIRCUITBREAKER CIRCUITBREAKER
OO
OFFOFF
OUTPUTOUTPUT
19.1 (485.1mm)19.1 (485.1mm)
18.5 (469.9mm)
17.4 (442mm)
NOMINAL LINE CORD=6'TOLERANCE + 12"
-12"
CIRCUITBREAKER CIRCUITBREAKER
CIRCUIT BREAKERPRESS TO RESETCIRCUIT BREAKERPRESS TO RESET
REMOTE PORTREMOTE PORT
OO
OFFOFF
SELECTSELECT
OUTPUTOUTPUT
CIRCUIT BREAKERPRESS TO RESETCIRCUIT BREAKERPRESS TO RESET
CIRCUIT BREAKERPRESS TO RESETCIRCUIT BREAKERPRESS TO RESET
CIRCUIT BREAKERPRESS TO RESETCIRCUIT BREAKERPRESS TO RESET
18.5 (470mm)
15.2
(38
6.1m
m)
7.70 (195.6mm)
U1000-ORM U2000-ONL & U3000-ONL
Refer to page 47 for additional dimensional drawings.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
MODEL U1000-SK U1500-SK U3000-SK U0800-SRM U1500-SRM U3000-SRM
Capacity 1000VA 1500VA 3000VA 800VA 1500VA 3000VA600W 900W 1800W 480W 900W 1800W
Voltage 120V +/-25% @ 50 or 60Hz (auto sensing)Voltage (on Battery) 120V +/-5% @ 50 or 60Hz (auto sensing)Voltage Regulation Increases output voltage 15% above input when -9 to -25% below nominal.
Decreases output voltage 15% below input when +9 to +25% above nominal.Wave Form (on Battery) Pure sine waveSurge Per IEEE C-62.41EMI/RFI Filter 10dB @ .15MHz, 50dB @ 30MHzType Hot swappable, sealed maintenance-free lead acidRecharge Time 4 hrs. (90% capacity)Protection Automatic self-test and discharge protection. Battery replacement indicator.Battery Back-up Slow beeping soundBattery Low Rapid beeping soundOverload Continuous tone
CATALOG NO. COLOR DESCRIPTION NET WEIGHT (lbs.)
U1000-SK Beige Line Interactive, Pure Sine Wave, Tower, 1000VA, 334-Outlets, Surge, Software
U1500-SK Beige Line Interactive, Pure Sine Wave, Tower, 1500VA, 556-Outlets, Surge, Software
U3000-SK Beige Line Interactive, Pure Sine Wave, Tower, 3000VA, 1216-Outlets, Hard-Wire, Surge, Software
U0800-SRM Black Line Interactive, Pure Sine Wave, 3U Rack Mount, 40800VA, 4-Outlets, Surge, Software
U1500-SRM Black Line Interactive, Pure Sine Wave, 3U Rack Mount, 57.51500VA, 4-Outlets, Surge, Software
U3000-SRM Black Line Interactive, Pure Sine Wave, 4U Rack Mount, 102.33000VA, 6-Outlets, Hard-Wire, Surge, Software
SPECIFICATIONS & FEATURESLev-UPS™ SINE SERIES
• Line Interactive Topology. (AVR)
• Pure Sine Wave Output (on battery)• Lev-WARE power monitoring & UPS
control software.
• AC and dataline surge protection.
• RS-232 & dry contact signaling.• 2 year product warranty – parts,
workmanship, and battery.(Optional extension to 5 years)
• $75,000 connected equipment warranty.
• UL 1778 & cUL listed, FCC compliant & ISO 9001 Certified.
Lev-UPS™ Sine SeriesU1000-SK, U1500-SK, U3000-SK, U0800-SRM, U1500-SRM, U3000-SRM
2 YEAR LIMITED
37
Lev-UPS™ Sine Series
Input
Output
Protection &Filtering
Battery
Alarms
U3000-SK
U3000-SK
U1500-SRM U0800-SRM
Multi-Function LCDDisplay
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
LOAD U1000-SK U1500-SK U3000-SK U0800-SRM U1500-SRM U3000-SRMVA/WATTS
250/175 42 70 182 45 70 178500/350 14 26 96 17 26 93750/125 9 19 72 10 19 701000-700 5 13 49 – 13 471200/720 – 8 36 – 8 361500/900 – 5 29 – 5 291800/1080 – – 23 – – 232000/1200 – – 20 – – 192500/1500 – – 15 – – 153000/1800 – – 11 – – 10
Lev-UPS™ Sine SeriesU1000-SK, U1500-SK, U3000-SK, U0800-SRM, U1500-SRM, U3000-SRM
2 YEAR LIMITED
38
Applications
• Computers and Peripherals• Medium to Large Servers• Phone and Telecommunication Systems• Electronic Cash Registers &
Point-of-Sale Equipment• Medical and Related Equipment
• Commercial and Industrial Automation• Lab, Test and Measurement Equipment• Internet Access Terminals• Lighting Controls• Security Systems• Data Processing Equipment
Back-up Times (in minutes)
U1000-SK U1500-SK
Refer to page 47 for additional dimensional drawings.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
U0600-ARM
U0600-ARM
MODEL U0500-AKP U0600-ARM
Capacity 500VA 600VA300W 360W
Voltage 120V +/-25% @ 50 or 60Hz (auto sensing)Voltage (on Battery) 120V +/-5% @ 50 or 60Hz (auto sensing)Voltage Regulation Increases output voltage 15% above input when -9 to -25% below nominal.
Decreases output voltage 15% below input when +9 to +25% above nominal.Wave Form (on Battery) Simulated sine waveSurge Per IEEE C-62.41EMI/RFI Filter 10dB @ .15MHz, 50dB @ 30MHzOverload Protection Automatic UPS shutdown if overload exceeds 110% of nominal for 60sec; 130% for 3sec10 Base-T Port Network (UTP, RJ-45) compatible jacks,. Short Circuit UPS output cutoff immediately or input fuses blow.Type Sealed maintenance-free lead acid.Recharge Time 4 hrs. (90% capacity)Protection Automatic self-test and discharge protection. Battery replacement indicator.Battery Back-up Slow beeping soundBattery Low Rapid beeping soundOverload Continuous tone
CATALOG NO. COLOR DESCRIPTION NET WEIGHT (lbs.)
U0500-AKP Beige Line Interactive, Simulated Sine Wave, 1U 500VA, 18.75-Outlets, Surge, Software
U0600-ARM Black Line Interactive, Simulated Sine Wave, 1U Rack 23.2Mount, 600VA, 5-Outlets, Surge, Software
SPECIFICATIONS & FEATURESLev-UPS™ SLIM SERIES
• Line Interactive Topology. (AVR)
• Lev-WARE power monitoring & UPS control software
• AC and dataline surge protection.
• RS-232& dry contact signaling.• 2 year product warranty – parts,
workmanship, and battery.
• $60,000 connected equipment warranty and exclusive computer monitor under-voltage warranty.
• UL 1778 & cUL listed, FCC compliant & ISO 9001 Certified
Lev-UPS™ Slim SeriesU0500-AKP & U0600-ARM
2 YEAR LIMITED
39
Lev-UPS™ Slim Series
Input
Output
Protection &Filtering
Battery
Alarm
U0500-AKP
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
LOAD U0500-AKP U0600-ARMVA/WATTS
75/45 70 150150/90 32 63
300/200 15 22
500/300 5 9600/360 – 7
Lev-UPS™ Slim SeriesU0500-AKP & U0600-ARM
2 YEAR LIMITED
40
Applications
• Computers and Peripherals• Small to Medium Servers• Data Processing Equipment• Electronic Cash Registers &
Point-of-Sale Equipment• Lab, Test and Measurement Equipment
• Phone and Telecommunications Systems• Process Control• Internet Access Terminals• Security Systems• Lighting Controls• Automation
Back-up Times (in minutes)
U0600-ARM
Refer to page 47 for additional dimensional drawings.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
MODEL U0425-AKP U0625-AKP U1000-AKP U1500-AKP U2200-AKP
Capacity 425VA 625VA 1000VA 1500VA 2200VA255W 375W 600W 900W 1320W
Voltage 120V +/-25% @ 50 or 60Hz (auto sensing)Voltage (on battery) 120V +/-5% @ 50 or 60Hz (auto sensing)Voltage Regulation Increases output voltage 15% above input when -9 to -25% below nominal.
Decreases output voltage 15% below input when +9 to +25% above nominal.Wave Form (on Battery) Simulated sine waveSurge Per IEEE C-62.41EMI/RFI Filter 10dB @ .15Mz, 50dB @ 30MHzOverload Protection Automatic UPS shutdown if overload exceeds 110% of nominal for 60sec; 130% for 3sec10 Base-T Port Network (UTP, RJ-45) compatible jacks,. Short Circuit UPS output cutoff immediately or input fuses blow.Type Sealed maintenance-free lead acid.Recharge Time 4 hrs. (90% capacity)Protection Automatic self-test and discharge protection. Battery replacement indicator.Battery Back-up Slow beeping soundBattery Low Rapid beeping soundOverload Continuous tone
CATALOG NO. COLOR DESCRIPTION NET WEIGHT (lbs.)
U0425-AKP Charcoal Line Interactive, Simulated Sine Wave, Tower, 12.8425VA, 2-Outlets, Surge, Software
U0625-AKP Charcoal Line Interactive, Simulated Sine Wave, Tower, 14.3625VA, 2-Outlets, Surge, Software
U1000-AKP Beige Line Interactive, Simulated Sine Wave, Tower, 331000VA, 5-Outlets, Surge, Software
U1500-AKP Beige Line Interactive, Simulated Sine Wave, Tower, 401500VA, 6-Outlets, Surge, Software
U2200-AKP Beige Line Interactive, Simulated Sine Wave, Tower, 572200VA, 6-Outlets, Surge, Software
SPECIFICATIONS & FEATURESLev-UPS™ PRO SERIES
• Line Interactive Topology. (AVR)
• Lev-WARE power monitoring & UPS control software
• AC and dataline surge protection.
• RS-232& dry contact signaling.• 2 year product warranty – parts,
workmanship, and battery.
• Connected equipment warranty - $40,000 for U0425-AKP, $60,000 for U0625-AKP & $75,000 for U1000-AKP, U1500-AKP & U2200-AKP
• Exclusive computer monitor under-voltage warranty.
• UL 1778 & cUL listed, FCC compliant & ISO 9001 Certified
Lev-UPS™ Pro SeriesU0425-AKP, U0625-AKP, U1000-AKP, U1500-AKP & U2200-AKP
2 YEAR LIMITED
41
Lev-UPS™ Pro Series
Input
Output
Protection &Filtering
Battery
Alarm
U0425-AKPU0625-AKP
U2200-AKP
U1000-AKP
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
LOAD U0425-AKP U0625-AKP U1000-AKP U1500-AKP U2200-AKPVA/WATTS
75/45 78 70 80 118 246150/90 27 28 55 73 126
300/200 10 13 32 38 75
425/255 4 9 20 25 52500/300 – 6 13 21 42
625/375 – 4 7 19 291000/600 – – 4 17 24
1200/720 – – – 12 19
1500/900 – – – 5 14
1800/1080 – – – – 92200/1320 – – – – 5
Lev-UPS™ Pro SeriesU0425-AKP, U0625-AKP, U1000-AKP, U1500-AKP & U2200-AKP
2 YEAR LIMITED
42
Applications
• Computers and Peripherals• Small to Medium Servers• Data Processing Equipment• Electronic Cash Registers &
Point-of-Sale Equipment• Commercial & Industrial Automation
• Phone and Telecommunications Systems• Lab, Test and Measurement Equipment• Internet Access Terminals• Security Systems• Lighting Controls• Home Automation• Entertainment
Back-up Times (in minutes)
U0425-AKP & U0625-AKP
Refer to page 47 for additional dimensional drawings.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
CATALOG NO. COLOR DESCRIPTION NET WEIGHT (lbs.)
U0320-SKO Charcoal Off-Line, Simulated Sine Wave, 320VA, 7.76-Outlets, Surge, Software
U0520-SKO Charcoal Off-Line, Simulated Sine Wave, 520VA, 116-Outlets, Surge, Software
SPECIFICATIONS & FEATURESLev-UPS™ STRIP SERIES
• Lev-WARE power monitoring & UPS control software
• AC and dataline surge protection.
• 2 year product warranty – parts,workmanship, and battery.
• Connected equipment warranty - $40,000 for U0320-SKO & $60,000 for U0520-SKO
• UL 1778 & cUL listed, FCC compliant & ISO 9001 Certified
Lev-UPS™ Strip SeriesU0320-SKO & U0520-SKO
2 YEAR LIMITED
43
Lev-UPS™ Strip Series
MODEL U0320-SKO U0520-SKO
Total Capacity 1800VA (1480VA surge + 320VA backup) 1800VA (1280VA surge + 520VA backup)
Voltage 120V AC @ 50 or 60Hz +/-10%Type Simulated sine waveBackup Capacity 320VA (192W) 520VA (312W)Voltage 120V AC -20 + 10% @ 50 or 60MHz +/-10%Transfer Voltage Under Voltage: 98V Typically
Over Voltage: 132V TypicallySurge Per IEEE C-62.41EMI/RFI Filter 10dB @ .15MHz, 50dB @ 30MHzTel/Fax/Modem Single line (2-wire, RJ45) or networkType Sealed maintenance-free lead acid.Recharge Time 4 hrs.(90% capacity)Protection Automatic self-test and discharge protection. Battery replacement indicator.Life Expectancy 3-6 yrs. dependent on no. of discharge cycles and ambient temperature.Replacement Model CSB HR 1214W CSB HC 1221WBattery Back-Up Rapid beeping soundBattery Low Continuous tone
Input
Output
Protection &Filtering
Battery
Alarm
Side Views U0320-SKO
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
LOAD U0320-SKO U0520-SKOVA/WATTS
75/45 19 28150/90 8 17
320/192 3 7500/300 – 3
Lev-UPS™ Strip SeriesU0320-SKO & U0520-SKO
2 YEAR LIMITED
44
Applications
• Computers and Peripherals• Phone and Telecommunications Systems• Electronic Cash & Point-of-Sale Equipment• Lighting Controls• Internet Access Terminals
• Internet Access Terminals• Home Automation• Entertainment
Back-up Times (in minutes)
U0320-SKO & U0520-SKO
Refer to page 47 for additional dimensional drawings.
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
IN
OUT
CIRCUITBREAKER
REMOTEPORT
ON
OFF
CIRCUITBREAKER
CIRCUITBREAKER
CIRCUITBREAKER
SELECT
19.0 (482.6 mm)
22.0 (558.8 mm)
7.0
(177
.8 m
m)
U0800-SRM - Pages 37-38 U1500-SRM - Pages 37-38U3000-SRM - Pages 37-38
U1000-ONL - Pages 35-36
CIRCUIT BREAKERPRESS TO RESET
INPUT
REMOTE PORT
ON
OFF
SELECT
OUTPUT 8.5
(215
.9 m
m)
15.8 (401.3 mm)
5.7 (144.8 mm)
TEST
BATTERY PACK
SELECT
OFF
ON
IN
OUTPUT
REMOTE PORT
OUT
SITEWIRINGFAULT
CIRCUIT BREAKER
INPUT
OUTPUTOUTPUTOUTPUT
CIRCUIT BREAKERCIRCUIT BREAKERCIRCUIT BREAKER
17.7 (449.6 mm)
16.6
(42
1.6
mm
)
6.7 (170.2 mm) CIRCUITBREAKER
OUTPUT
OFF
ON
CIRCUITBREAKER
PORTREMOTE
SELECT
EXT. BAT.
CIRCUITBREAKER
19.1 (485.1 mm)
18.5 (470 mm)
21.7 (551.2 mm)
5.2
(132
.1 m
m)
U2000-ORM / U3000-ORMPages 35-36
U3000-SK - Pages 37-38
U1500-AKP / U1000-AKPPages 41-42
U2200-AKP - Pages 41-42U0500-AKP - Pages 39-41
Lev-UPS™Additional Dimensional Drawings
45 For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
Buck and Boost Regulation – (“Lev-CON™”)An automatic voltage regulator that boosts up or bucksdown the voltage to compensate for minor input fluctua-tions constitutes a line interactive design. Lev-CON™ usesa fast, microprocessor controlled circuit to switch betweendifferent taps or windings on a transformer to raise or lowerthe voltage as needed.
Clamping VoltageThe peak voltage occurring on a conductor, measured atthe output of a surge protection device to either the groundor neutral conductor.
Common ModeSignals that appear equally and in phase from each current-carrying conductor to ground.
EMI/RFI Noise FiltrationElectro-Magnetic Interference(EMI) and Radio FrequencyInterference(RFI) are disruptions on the smooth AC powerline sine wave. This noise on the power line can be causedby lightning, generators, radio transmitters or even house-hold appliances. This noise shows up as glitches or errorson computer systems, or “snow” on a TV.
JouleThe work done when the point of application of a force ofone newton is displaced a distance of one meter in thedirection of the force.
Line Interactive (Lev-CON™)By incorporating an automatic voltage regulator, this topology allows for much wider input voltage swings andcompensates for minor sags and swells in the line voltagewithout the need to transfer to battery, thus extending battery life.
Maximum Continuous Operating Voltage (MCOV)The maximum designated root mean square (rms) value ofpower frequency voltage that may be applied continuouslybetween the terminal of an arrestor.
Normal ModeSignals measured among active circuit conductors feeding the subject load but not between the equipmentgrounding conductor.
Off-LineThis refers to the simplest topology available, where theUPS transfers to battery power only when a low voltagelevel is breached. Under normal conditions, the utilitypower supplies the load. Off-line is typically used to backup less critical loads with a wide input voltage tolerance.
On-LineThis is the highest level of conversion and the battery/inverteris always connected to the load. As a result, there is no breakin power (i.e. no transfer time), which makes it ideal for themost critical applications. On-line also isolates the loadfrom most other power disturbances.
Pure Sine Wave OutputThis is the output wave shape from higher-end UPS prod-ucts and it is required for applications where the protectedload will not tolerate a simulated sinewave. Examples ofthis are loads that rely on the 60Hz sinusoidal waveformfor tracking, timing or clock functions and those thatrequire extended backup times.
Redundant ProtectionA module provides primary surge suppression for itsassigned phase and also secondary, or back-up, suppressionfor another phase in a three-phase system.
Sine Wave TrackingExtended range linear filtering throughout the sinewave curve offering uniformtransient voltage surge suppression regardless of the phase angle polarity.
Simulated/Pseudo Sine Wave OutputThis is a common output wave shape that is compatiblewith most loads. It is superior to a simple square-wave inthat it produces a peak voltage and an RMS voltage similarto that of a sine wave. The simulated sine wave is simpler tocreate and just as reliable as a sine wave. Also referred toas a “stepped approximation to a sine wave”.
Transfer Time The time it takes to transfer from utility power to batterypower in the event of an interruption. Most designs use thezero-crossing point for detection and typically transfer inapproximately 2/4 milliseconds, including detection time.Transfer time only applies to Off-line and Line-interactiveunits, since On-line units are always active & do notrequire a transfer to and from battery.
UL 497AApplies to secondary phone line protection.
UL 497BApplies to data with respect to phone line protection.
UL 1449Applies to Transient voltage surge suppression (TVSS) withrespect to power sources.
UL 1778Applies to Uninterruptible Power Supplies (UPS).
0
0 90 180 270 360
CommercialPower Envelope
(170 Vpeak +/– 15%)
PHASE ANGLE (Degrees)
Lev-UPS™ Glossary of Terms
46For answers to technical questions call our Techline at 1-800-824-3005 or visit us at: � www.leviton.com/powerquality
When describing performanceof Surge Protective Devices,many factors play a part indetermining the effectivenessof these products. This canmake it difficult to carry out areasonable comparison betweenperformance characteristics ofcompeting products. Therefore,the Institute of Electrical andElectronic Engineers, or IEEE,established uniform requirementsthat characterize the environ-ments for evaluating the perform-ance of Surge Protective Devices.
Standard C62.41 describesthree general categories ofoperating environment forSurge Protective Devices. Asshown in Figure 2, the threesystem exposure environmentsare called Category A,Category B, and Category C.
With operating environmentcategories well defined, theIEEE also established a veryprecise description of severaltransient voltage and currentwaveforms that would beexpected within each of theseareas. The transient waveformsare configured as ringwavesand combination waves.Charts 1 and 2 show the exactparameters that describe thesewaveforms in Category A, Band C operating environments.
Note that for Categories A and B, there are low, mediumand high-exposure ringwavetransients shown in Chart 1. In Chart 2, there are low,medium and high-exposurecombination-wave transientlevels for Categories B and C.
ServiceEntrance Meter
Meter
Outbuilding
Underground Service
ServiceEntrance
OutbuildingTransformer
Underground Service
ServiceEntrance
A B C
Demarcation between Location Categories B and C is arbitrarily taken to be at the meter or at the mains disconnect (ANSI/NFPA 70-1990 {2}, Article 230-70) for low-voltage service, or at the secondary of service transformer if the service is provided to the user at a higher voltage.
A• Outlets & long
branch circuits
• All outlets at more than 10m (30ft.) from Category B
• All outlets at more than 20m (60ft.) from Category C
B• Feeders and short branch circuits• Distribution panel devices• Bus and feeder industrial plants• Heavy appliance outlets with “short”
connections to service entrance• Lighting systems in large buildings
C• Outside and
service entrance• Service drop from
pole to building• Run between
meter&panel• Overhead line to
detached building• Underground
line to well pump
Figure 2An Objective Measure OfSurge Protective DevicePerformance —The IEEE C62 StandardsCollection
47
Since 1987, Underwriters Laboratorieshas tested performance of surge protective devices using IEEE C62Standards for Categories A, B and C as shown in Charts 1 and 2.
In 1998, UL revised its UL 1449testing specifically to address the“fail-safe” operation of surge sup-pression components within surgeprotective devices. The 1998 UL1449 includes testing that coversabnormal service conditions andend-of-life degradation modes char-acteristic of metal-oxide varistors.
The scope and methodology ofrevised UL 1449 testing varies inmany ways from the older standard,but three new tests are of majorsignificance:
• Temporary Overvoltage — Thedevice is connected to 125% ofthe normal system voltage forseven hours, and there must notbe any risk of fire or shock hazardas a result.
• Full-Phase System Overvoltage —This subjects the device beingtested to a simulated “loss of neutral.” For example, a 120-Voltdevice intended for use in120/240 Volt systems will be con-nected to 240V, and there mustnot be any risk of fire or shockhazard as a result.
• Limited Current Overvoltage — Inthis test, the device is subjected toincreasing levels of “stand-by cur-rent” through each mode wherean MOV is connected. The test
simulates an end-of-life MOVdegradation, or thermal-runawayscenario, and there must not beany risk of fire or shock hazard asa result. Moreover, verificationalso includes dielectric withstand(hipot) and leakage-current tests.
As before, the revised 1998 UL1449 also tests to establish clampingperformance and assigns SuppressedVoltage Ratings (SVR) at levelsshown in Chart 3. Subsequent totesting, actual clamping valuesdemonstrated by the device arerounded UP to the nearest level. By rounding UP ONLY, buyers of UL Listed surge protective devicesare assured that the performancerepresents a reliable minimum level of protection available from the device. The SVR for various categories of performance testedalways appear on the UL label indicating the device is UL 1449Listed as a surge protective device.
IndependentVerification ofClamping LevelData — TheUL1449 Listing
1998 REVISION UL1449SUPPRESSED VOLTAGE
RATINGS (SVR)
330V pk 1500V pk
400V pk 1800V pk
500V pk 2000V pk
600V pk 2500V pk
700V pk 3000V pk
800V pk 4000V pk
900V pk 5000V pk
1000V pk 6000V pk
1200V pk
Chart 3
Chart 1Standard 0.5 µs-100 kHz Ring Wave
Voltages and Current Surges Expected in Location Categories A and BLow, Medium and High Exposures
Single-Phase Modes: L-N, L-G, and [L&N]-GPolyphase Modes: L-L, L-G, and [L’s]-G
Peak Values EffectiveLocation System Voltage Current ImpedanceCategory Exposure (kV) (kA) (Ω)
A1 Low 2 0.07 30A2 Medium 4 0.13 30A3 High 6 0.2 30
B1 Low 2 0.17 12B2 Medium 4 0.33 12B3 High 6 0.5 12
Chart 2Standard 1.2/50 µs-8/20 µs Combination Wave
Voltages and Current Surges Expected in Location Categories B and CLow, Medium and High Exposures
Single-Phase Modes: L-N, L-G, and [L&N]-GPolyphase Modes: L-L, L-N, L-G, and [L’s]-G
Peak Values Effective Location System Voltage Current ImpedanceCategory Exposure (kV) (kA) (Ω)
B1 Low 2 1 2B2 Medium 4 2 2B3 High 6 3 2
C1 Low 6 3 2C2 Medium 10 5 2C3 High 20 10 2
Testing to IEEE C62.41Standards Confirms Surge Protective DevicePerformanceUsing the IEEE Standard waveforms,all manufacturers of Surge ProtectiveDevices now have a common basisfor making comparisons. When subjected to consistent, well-definedtransient waveforms in Categories A, B and C, manufacturers have themeans to offer objective and consis-tent test results that document theeffectiveness of their products insuppressing transient voltage surges.Be wary of manufacturers that claimtheir Surge Protective Devices “PASSor EXCEED IEEE Standard C62,”because such claims are meaning-less. The C62 Standards cannot bepassed or failed, or exceeded. Theysimply serve as a yardstick for usewhen testing and documenting theperformance of Surge ProtectiveDevices.
48
Using the NEMALS-1 Format ForPreparing SurgeProtective DeviceSpecifications
The NEMA LS-1 Specification Format For Surge Protective Devices.
Because of the volume of data publishedby the manufacturers of Surge ProtectiveDevices, creating a specification for thesedevices is vulnerable to omissions orinconsistencies. Recognizing the need for a consistent, reliable specificationstructure, the National ElectricalManufacturer’s Association, or NEMA, hasdeveloped the NEMA LS-1 SpecificationFormat for Surge Protective Devices.Note that NEMA does not include Joule energy and device response time as relevant parameters due totheir arbitrary nature.Response time is typically meant to indicate the device’s ability to “activate”itself when a high rise time/high-frequencytransient occurs. All response time values are based upon theoretical calculations. Based on facility wiring (and the nature of transient sources which are typicallylimited to frequencies below 20 MHz,and often below 2 MHz), the turn-ontimes of most Surge Protective Devicesare far above these values, making theneed for high-frequency fast-responseparameters irrelevant.A brief review of the elements comprisingthe NEMA LS-1 format will be helpful indefining the information to be shown.1. DEVICE NAME AND MODEL NUMBER: Available from manufacturer’spublished literature and specifications.2. DEVICE CIRCUIT DESCRIPTION: Thisdefines the components within the SurgeProtective Device that actually suppresstransient voltage surges. Examples includesingle or multiple Metal Oxide Varistors(MOV’s), gas-tube design, hybrid circuit,and others. This also indicates whether thedevice is series or parallel operated.3. NOMINAL LINE VOLTAGE: Whetherthe device is panel-mounted, a plug-inunit, or a hard-wired unit, the intendedline voltage for its application should bespecified.4. MAXIMUM CONTINUOUS OPERATING CURRENT: This rating mustbe specified for Surge Protection Devicesthat contain in-line series-connectedcomponents in their circuit design to confirm that the device will be operatedwithin the circuit ampacity limits and notbe overheated when installed.5. MAXIMUM CONTINUOUS OPERATING VOLTAGE (MCOV): TheMCOV is typically dictated by the assignedrating of the MOV’s within the surge protection device. The MOV rating isestablished by the MOV manufacturerrather than by the maker of the Surge
Protective Device. This value provides aceiling for the device’s vulnerability tobeing degraded as a result of line-voltageswells.6. CONNECTION MEANS: Depending on the type of device, this could be lug terminals, terminal screws, wire leads,plug-in, or others.7. PROTECTION MODES: For point-of-use devices, three modes of surge protection should be provided: line toneutral, line to ground, and neutral toground. Of course, clamping data shouldbe furnished for each mode. In the caseof panel-mounted units, especially thoseinstalled on delta systems or at serviceentrances where ground and neutral are bonded, the devices may provideadequate protection even though every possible suppression mode is not applicable. 8. MAXIMUM SURGE CURRENT:This is a measure of how robust a SurgeProtective Device may be in the face ofextremely high peak currents associatedwith, for example, lightning-inducedsurges. The standard of measure is a single-pulse 8x20μ sec waveform specified in IEEE Standard C62.45. It isimportant that this information be providedby actual testing of the device, and notonly from calculations based on manufacturer’s component specifications.9. CLAMPING VOLTAGE: The clampingrating of a Surge Protective Device is theresult of tests conducted using the IEEEC62 Standards Collection waveforms. It’simportant for these values to show clamp-ing levels with respect to zero groundlevel, and with line voltage applied. Also,clamping data should be provided foreach protection mode the device offers.
10. EMI/RFI NOISE REJECTION:Electromagnetic interference (EMI) andradio frequency interference (RFI) shouldbe attenuated by Surge ProtectionDevices in the frequency ranges speci-fied. Test methods are based on 50Ωinsertion loss procedures outlined in MIL-STD 220A.11. SAFETY AGENCY APPROVALS:Certification organizations like UL, CSA,and NOM, should be specified along withtheir appropriate test standards, productcategories, and reference file numbers. Forexample, in the case of a plug strip, the ULlisting would be based on evaluation understandards UL 1449 TVSS (XUHT) and alsoUL 1363 Temporary Power Taps (XBYS). Inaddition, manufacturers are assigned filenumbers for their listed devices. XUHT andXBYS are UL product identifiers (CCNDirectory Codes).12. SAFETY AGENCY RATINGS: Safetyagencies assign suppression (clamping)ratings based on requirements in appli-cable test standards. For instance, the UL1449 rating levels that appear in Chart 3are used to determine clamping ratingsfor UL listed Surge Protective Devices. Itis important to note that CSA and ULboth prohibit outdoor installation ofthese devices unless they’re protected by an additional suitable enclosure likea NEMA-3R box, for example.13. PHYSICAL DATA: Available frommanufacturer’s specifications, this entryspells out device dimensions, weights,materials composition and other physi-cal characteristics.The information on all Leviton SurgeProtective Devices in this brochure isdesigned to facilitate use of the NEMALS-1 Specification Format.
NEMA LS-1 SPECIFICATION FORMAT
FOR SURGE PROTECTIVE DEVICES
SPD Model: _______________________________________________________________
SPD Circuit Description ______________________________________________________
Nominal Line VoItage: ______________________________________________________
Maximum Continuous Line Current: ___________________________________________
Maximum Continuous Operating VoItage: _______________________________________
Connection Means: ________________________________________________________
SPD Protection Modes: _____________________________________________________
Maximum Surge Current: ____________________________________________________
(Single Pulse, 8/20 µs, Mode, Data obtained from actual tests)
Clamping VoItage during Maximum Surge Current (VPeak measured): __________________
Clamping Voltage: _________________________________________________________
(Data taken at 90 degrees phase angle of power frequency voltage,
positive polarity only, applicable surge current)
EMI-RFI Noise Rejection: ____________________________________________________
Safety Approvals (Agency, Standard, File): _________________________________________
Safety Ratings (UL1449, VPeak): ______________________________________________
Application Environment: _____________________________________________________
PHYSICAL DATA:
Dimensions: _______________________________________________________________
Weight: __________________________________________________________________
Materials: _________________________________________________________________
Wlre size and length: ________________________________________________________
Accessories: ______________________________________________________________
49
Defending Against TransientVoltage Surges In Industrial,Commercial andResidential Settings
For the demands of industrial environments, Leviton provides a selection of surge protectivedevices that can be wired in at service panels, branch panels,
and at load sites. These devices are provided ina broad selection of ratings from 120V AC
single-phase to 600V AC three-phase DELTA.
Leviton BacksYou WithStrong SupportPower Quality Site Surveys
Leviton specialists can conductpower-quality audits in any facility.By means of sophisticated electronicsurge counters, the level of voltagetransients, and their severity, can be monitored. Using a site surveyworkbook, Leviton specialists canprepare a report that outlines:
• Equipment at risk. • Potential losses due to downtime. • Recommended surge protective
devices.• Effective application strategies.
Power Quality Learning Labs
Leviton’s technical specialists canpresent a comprehensive seminar thatcovers all aspects of power quality,with an emphasis on transient voltagesurge suppression. The informationpresented includes types of surges,
their origins, and effects. It alsoexamines different surge protectivedevices, appropriate applications,and network protection strategies.
Superior Warranty Protection
For many of its industrial gradesurge protective devices, Levitonprovides a Lifetime LimitedDownline Warranty. This warrantycovers not only the surge protective
device, but also the equipment itprotects. To see the provisions ofthis warranty, and also of Leviton’sLimited Ten Year Warranty, refer topages 53 and 54 respectively.
Fast Answers To TechnicalQuestions
Trained technical specialists staffLeviton’s Techline. The toll-freeTechline number is (800) 824-3005.
Commercial and institutional facilities are equipped with a largevariety of electronic equipmentthat’s vital to their operation.Leviton has the surge protection
solutions that defend this equipmentagainst the effects of transient voltagesurges. In business offices, schools,retail stores, malls, banks, government
facilities and elsewhere, Levitondevices can protect individualitems of equipment, entirebranch circuits, and evenentire facilities, starting at the
electrical service entrance.
Virtually every home contains micro-processor-driven electronic equipment,particularly with the increased populari-ty of home offices and home entertain-ment centers. Leviton provides high-performance surge protective devices tosafe-guard computer workstations and peripherals,televisions, audio equip-ment, and all other house-hold electronics.
Leviton also provides surge protective devices designed for usein programmable-logic controllers,factory-automation and data linksusing Allen-Bradley controllersoperating on “Blue Hose” networks.Leviton is a participating supplierin Rockwell Automation’sEncompass Program.
50
10 YEAR LIMITED
51
Leviton Surge Repair or Replacement Suppression Product Maximum
5100 Strips, Up to $5,000 repair Plug-ins or replacement 4950-PS Strips coverage of all properly 4900-P Plug-ins connected equipment
due to failure of the suppressor.
5200 Strips, Up to $10,000 repair 5505 Rack-mount or replacement
coverage of all properly connected equipment due to failure of the suppressor.
5300 Strips, Plug-ins; Up to $25,000 repair or replacement coverage of all
5500 Rack-mount;
properly connected 5350-PT4, 5350-PT8,
equipment due to failure5350-PC, 5350-SAT,
of the suppressor.Plug-in modules
5950 Strips Up to $50,000 repair orreplacement coverage of all properly connectedequipment due to failureof the suppressor.
To receive payment for replacement orrepair to damaged, properly connectedelectronic equipment due to a “powerdisturbance”, the original purchasershould have such equipment repairedby an authorized service center of suchequipment’s manufacturer, have therepair bill together with the Levitonsurge suppressor and proof of purchaseby the original purchaser sent to theabove Leviton address (ATTN: QUAL-ITY ASSURANCE DEPARTMENT:LEVITON LITTLE NECK) with a state-ment from the repair facility document-ing the nature of the damage, and a
This warranty, subject to all the provisionsbelow, gives you specific legal rights, andyou may also have other rights that varyfrom state to state. This warranty appliesonly to Leviton’s SPD Surge Suppressorcatalog numbers listed in the warrantychart to the right.
Leviton warrants to the original consumer purchaser, and solely for the benefit of such original consumerpurchaser, that the Leviton SurgeSuppressor is free of defects in materials and workmanship so long assuch original consumer purchaser usessuch Leviton Surge Suppressor. Levitonwill correct such defects in its Surge Suppressor by repair or replacement at its option if the SurgeSuppressor is returned prepaid, withproof of purchase by the original pur-chaser, to: ATT: Quality AssuranceDept., Leviton Manufacturing Co., Inc.,59-25 Little Neck Parkway, Little Neck,New York 11362-2591.
This warranty also covers damage to any electronic equipment properlyconnected to Leviton’s SurgeSuppressor solely caused by a “power disturbance” as defined here-after. In the event that a “power distur-bance” damages properly connectedelectronic equipment and Levitondetermines that such damage was caused by the performance failure ofthe Leviton Surge Suppressor, Levitonwill reimburse the original consumer purchaser’s reasonable cost of repairing such damage or replacing such equipment according to the following schedule:
note from you explaining how the dam-age was sustained to such equipment.
As used in this warranty, a “power dis-turbance” means a transient voltagesurge/spike on the AC power, tele-phone, data or coaxial line, which volt-age surge/spike surge suppressors ofthe particular type covered by this war-ranty are generally designed to protectagainst in accordance with industrystandards. This warranty specificallydoes not cover sustained over-voltages.Warranty protection from physical dam-age is also provided for phone, data, orcoaxial line equipment, when connectedto Leviton communication line protec-tion products (5350-PT4, 5350-PT8,
This warranty does not cover anyLeviton surge suppressor or any prop-erly connected electronic equipmentwhich has been improperly installed,overloaded, abused or altered in anymanner or is not used under normaloperating conditions or in accordancewith any labels or instructions, and doesnot cover any damage to properly con-nected electronic equipment resultingfrom a cause other than a “power distur-bance”. This warranty does not apply todamage caused by direct lightningstrikes or damage caused by electricaldisturbances that exceed publishedproduct specifications. These productsare intended to limit the maximumamplitude of transient voltage surges onpower lines to specified values. Theyare not intended to function as surgearrestors. They are intended to beinstalled on the load side of the mainovercurrent protection. They have beentested to verify that transient voltagesurges are limited to the maximumamplitudes specified when subjected toa 1.2 by 50-microsecond 6 kv voltagesurge. This warranty excludes and thereis disclaimed liability for any incidental,indirect, special or consequential dam-ages, including without limitation, laborfor removal or reinstallation of theLeviton surge suppressor or any con-nected electronic equipment, data lossor alteration, loss of equipment use, lostsales or profits and any such damagesfor delay or failure to perform this war-ranty obligation. This warranty is in lieuof and excludes all implied warranties ofmerchantability or fitness for use. Theremedies provided herein are yourexclusive remedies under this warranty,whether based on contract, tort or other-wise. Some states may not allow theexclusion or limitations of incidental orconsequential damages or other reme-dies, so the above exclusions or imita-tions may not apply to you.
5350-PC and 5350-SAT).
52000
S3000
S1000
Outstanding Warranty ProtectionAll Leviton Surge Protective Devices provide unmatched
quality, top performance, and state-of-the-art engineering.
All are backed by Leviton’s limited ten-year warranty, or
the Lifetime Limited Downline
Warranty that backs selected
Leviton products and extends
coverage to the loads
they protect.
LEVITONLIFETIME LIMITED DOWNLINE
Leviton Lifetime LimitedDownline Warranty
52
53 LEVITON MANUFACTURING Co., Inc., 59-25 Little Neck Parkway, Little Neck, New York 11362-2591 www.leviton.com/powerquality
Catalog Number Alphanumeric IndexU0320-SKO . . . . . . . . . . .43-44U0425-AKP . . . . . . . . . . .41-42U0500-AKP . . . . . . . . . . .39-40U0520-SKO . . . . . . . . . . .43-44U0600-ARM . . . . . . . . . . .39-40
U0625-AKP . . . . . . . . . . .41-42U0800-SRM . . . . . . . . . . .37-38U1000-AKP . . . . . . . . . . .41-42U1000-ONL . . . . . . . . . . .35-36U1000-ORM . . . . . . . . . . .35-36
U1000-SK . . . . . . . . . . . . .37-38U1500-AKP . . . . . . . . . . .41-42U1500-SK . . . . . . . . . . . . .37-38U1500-SRM . . . . . . . . . . .37-38U2000-ONL . . . . . . . . . . .35-36
U2000-ORM . . . . . . . . . . .35-36U2200-AKP . . . . . . . . . . .41-42U3000-ONL . . . . . . . . . . .35-36U3000-ORM . . . . . . . . . . .35-36U3000-SK . . . . . . . . . . . . .37-38
U3000-SRM . . . . . . . . . . .37-381524D-R06 . . . . . . . . . . . . . .332119D-L06 . . . . . . . . . . . . . .333254 . . . . . . . . . . . . . . . . . . .243254-BLU . . . . . . . . . . . . . . .24
3254-E . . . . . . . . . . . . . . . . . .243254-GY . . . . . . . . . . . . . . . .243254-I . . . . . . . . . . . . . . . . . .243254-O . . . . . . . . . . . . . . . . .243254-R . . . . . . . . . . . . . . . . . .24
3254-W . . . . . . . . . . . . . . . . .243420-009 . . . . . . . . . . . . . . . .203420-035 . . . . . . . . . . . . . . . .203500-P . . . . . . . . . . . . . . . . . .303500-PC . . . . . . . . . . . . . . . .30
3500-PT . . . . . . . . . . . . . . . . .303800-0WM . . . . . . . . . . . . . .193800-DIN . . . . . . . . . . . . . . .193800-OEM . . . . . . . . . . . . . . .193801-DIN . . . . . . . . . . . . . . .25
3803-485 . . . . . . . . . . . . . . . .203803-CAN . . . . . . . . . . . . . . .203803-DHP . . . . . . . . . . . . . . .203803-MOD . . . . . . . . . . . . . .203803-SPX . . . . . . . . . . . . . . . .20
3812-0WM . . . . . . . . . . . . . .193812-DIN . . . . . . . . . . . . . . .193812-OEM . . . . . . . . . . . . . . .193824-0WM . . . . . . . . . . . . . .193824-DIN . . . . . . . . . . . . . . .19
3824-OEM . . . . . . . . . . . . . . .193840-0WM . . . . . . . . . . . . . .193840-DIN . . . . . . . . . . . . . . .193840-OEM . . . . . . . . . . . . . . .193848-0WM . . . . . . . . . . . . . .19
3848-DIN . . . . . . . . . . . . . . .193848-OEM . . . . . . . . . . . . . . .193860-CT5 . . . . . . . . . . . . . . .203860-GEF . . . . . . . . . . . . . . .203861-ETH . . . . . . . . . . . . . . .20
3862-CON . . . . . . . . . . . . . . .203863-DEV . . . . . . . . . . . . . . .203880-DIN . . . . . . . . . . . . . . .254254-BLU . . . . . . . . . . . . . . .244254-E . . . . . . . . . . . . . . . . . .24
4254-GY . . . . . . . . . . . . . . . .244254-I . . . . . . . . . . . . . . . . . .244254-O . . . . . . . . . . . . . . . . .244254-Y . . . . . . . . . . . . . . . . . .244505-20L . . . . . . . . . . . . . . . .33
4505-20T . . . . . . . . . . . . . . . .334800-PS . . . . . . . . . . . . . . . . .304800-PSN . . . . . . . . . . . . . . .304800-S15 . . . . . . . . . . . . . . . .304900-P . . . . . . . . . . . . . . . . . .30
4900-PC . . . . . . . . . . . . . . . .304900-PS . . . . . . . . . . . . . . . . .304900-PSC . . . . . . . . . . . . . . . .304900-PST . . . . . . . . . . . . . . . .304900-PT . . . . . . . . . . . . . . . . .30
4950-PS . . . . . . . . . . . . . . . . .314950-PSC . . . . . . . . . . . . . . . .314950-PST . . . . . . . . . . . . . . . .314950-S15 . . . . . . . . . . . . . . . .315100-G15 . . . . . . . . . . . . . . .29
5100-GS . . . . . . . . . . . . . . . .295100-IPS . . . . . . . . . . . . . . . .295100-IS2 . . . . . . . . . . . . . . . .295100-P . . . . . . . . . . . . . . . . . .315100-PS . . . . . . . . . . . . . . . . .29
5100-S15 . . . . . . . . . . . . . . . .295200-G15 . . . . . . . . . . . . . . .295200-GS . . . . . . . . . . . . . . . .295200-PS . . . . . . . . . . . . . . . . .295200-S15 . . . . . . . . . . . . . . . .29
5280 . . . . . . . . . . . . . . . . . . .215280-A . . . . . . . . . . . . . . . . .215280-B . . . . . . . . . . . . . . . . . .215280-GY . . . . . . . . . . . . . . . .215280-I . . . . . . . . . . . . . . . . . .21
5280-IG . . . . . . . . . . . . . . . . .215280-IGB . . . . . . . . . . . . . . . .215280-IGG . . . . . . . . . . . . . . .215280-IGI . . . . . . . . . . . . . . . .215280-IGO . . . . . . . . . . . . . . .21
5280-IGW . . . . . . . . . . . . . . .215280-W . . . . . . . . . . . . . . . . .215300-G15 . . . . . . . . . . . . . . .285300-GP . . . . . . . . . . . . . . . .315300-GS . . . . . . . . . . . . . . . .28
5300-GSC . . . . . . . . . . . . . . .285300-GST . . . . . . . . . . . . . . .285300-HTS . . . . . . . . . . . . . . .285300-H15 . . . . . . . . . . . . . . .285300-IPS . . . . . . . . . . . . . . . .28
5300-P . . . . . . . . . . . . . . . . . .315300-PS . . . . . . . . . . . . . . . . .285300-PSC . . . . . . . . . . . . . . . .285300-PST . . . . . . . . . . . . . . . .285300-S15 . . . . . . . . . . . . . . . .28
5350-PC . . . . . . . . . . . . . . . .345350-PT4 . . . . . . . . . . . . . . . .345350-PT8 . . . . . . . . . . . . . . . .345350-SAT . . . . . . . . . . . . . . . .345380 . . . . . . . . . . . . . . . . . . .22
5380-B . . . . . . . . . . . . . . . . . .225380-GY . . . . . . . . . . . . . . . .225380-I . . . . . . . . . . . . . . . . . .225380-IG . . . . . . . . . . . . . . . . .225380-IGB . . . . . . . . . . . . . . . .22
5380-IGG . . . . . . . . . . . . . . .225380-IGI . . . . . . . . . . . . . . . .225380-IGO . . . . . . . . . . . . . . .225380-IGW . . . . . . . . . . . . . . .225380-W . . . . . . . . . . . . . . . . .22
5480-BU . . . . . . . . . . . . . . . .235480-GY . . . . . . . . . . . . . . . .235480-I . . . . . . . . . . . . . . . . . .235480-IG . . . . . . . . . . . . . . . . .235480-R . . . . . . . . . . . . . . . . . .23
5480-W . . . . . . . . . . . . . . . . .235490-BU . . . . . . . . . . . . . . . .235490-GY . . . . . . . . . . . . . . . .235490-I . . . . . . . . . . . . . . . . . .235490-IG . . . . . . . . . . . . . . . . .23
5490-W . . . . . . . . . . . . . . . . .235500-15N . . . . . . . . . . . . . . .325500-190 . . . . . . . . . . . . . . . .325500-192 . . . . . . . . . . . . . . . .325500-20L . . . . . . . . . . . . . . . .32
5500-20N . . . . . . . . . . . . . . .325500-2NL . . . . . . . . . . . . . . .325500-NL . . . . . . . . . . . . . . . .325505-190 . . . . . . . . . . . . . . . .325950-0PS . . . . . . . . . . . . . . . .26
5950-0ST . . . . . . . . . . . . . . . .265950-PSG . . . . . . . . . . . . . . .265950-SCG . . . . . . . . . . . . . . .265950-SSG . . . . . . . . . . . . . . .265950-STG . . . . . . . . . . . . . . .26
5951-0SA . . . . . . . . . . . . . . . .275951-SAT . . . . . . . . . . . . . . . .275952-0ET . . . . . . . . . . . . . . . .275952-ETH . . . . . . . . . . . . . . .275953-0PC . . . . . . . . . . . . . . .27
5953-PCG . . . . . . . . . . . . . . .275954-AT4 . . . . . . . . . . . . . . . .275954-CT4 . . . . . . . . . . . . . . .275954-PT4 . . . . . . . . . . . . . . . .275955-0DT . . . . . . . . . . . . . . .27
5955-DTC . . . . . . . . . . . . . . .275955-DTG . . . . . . . . . . . . . . .275957-OC5 . . . . . . . . . . . . . . .275957-C5G . . . . . . . . . . . . . . .275958-AT4 . . . . . . . . . . . . . . . .27
5958-PT4 . . . . . . . . . . . . . . . .275959-BT8 . . . . . . . . . . . . . . . .275959-GT8 . . . . . . . . . . . . . . .277280 . . . . . . . . . . . . . . . . . . .217280-A . . . . . . . . . . . . . . . . .21
7280-B . . . . . . . . . . . . . . . . . .217280-GY . . . . . . . . . . . . . . . .217280-I . . . . . . . . . . . . . . . . . .217280-IG . . . . . . . . . . . . . . . . .217280-IGB . . . . . . . . . . . . . . . .21
7280-IGG . . . . . . . . . . . . . . .217280-IGI . . . . . . . . . . . . . . . .217280-IGO . . . . . . . . . . . . . . .217280-IGW . . . . . . . . . . . . . . .217280-W . . . . . . . . . . . . . . . . .21
7380 . . . . . . . . . . . . . . . . . . .227380-B . . . . . . . . . . . . . . . . . .227380-GY . . . . . . . . . . . . . . . .227380-I . . . . . . . . . . . . . . . . . .227380-W . . . . . . . . . . . . . . . . .22
8280 . . . . . . . . . . . . . . . . . . .218280-A . . . . . . . . . . . . . . . . .218280-B . . . . . . . . . . . . . . . . . .218280-I . . . . . . . . . . . . . . . . . .218280-IGB . . . . . . . . . . . . . . . .21
8280-IGG . . . . . . . . . . . . . . .218280-IGI . . . . . . . . . . . . . . . .218280-IGO . . . . . . . . . . . . . . .218280-IGW . . . . . . . . . . . . . . .218280-R . . . . . . . . . . . . . . . . . .21
8280-W . . . . . . . . . . . . . . . . .218281-IGI . . . . . . . . . . . . . . . .218281-IGO . . . . . . . . . . . . . . .218281-IGW . . . . . . . . . . . . . . .218380 . . . . . . . . . . . . . . . . . . .22
8380-B . . . . . . . . . . . . . . . . . .228380-GY . . . . . . . . . . . . . . . .228380-I . . . . . . . . . . . . . . . . . .228380-IGB . . . . . . . . . . . . . . . .228380-IGG . . . . . . . . . . . . . . .22
8380-IGI . . . . . . . . . . . . . . . .228380-IGO . . . . . . . . . . . . . . .228380-IGR . . . . . . . . . . . . . . . .228380-IGW . . . . . . . . . . . . . . .228380-R . . . . . . . . . . . . . . . . . .22
8380-W . . . . . . . . . . . . . . . . .228381 . . . . . . . . . . . . . . . . . . .228381-GY . . . . . . . . . . . . . . . .228381-I . . . . . . . . . . . . . . . . . .228381-IGB . . . . . . . . . . . . . . . .22
8381-IGI . . . . . . . . . . . . . . . .228381-IGO . . . . . . . . . . . . . . .228381-IGW . . . . . . . . . . . . . . .228480-I . . . . . . . . . . . . . . . . . .238480-IG . . . . . . . . . . . . . . . . .23
8480-IGW . . . . . . . . . . . . . . .238480-R . . . . . . . . . . . . . . . . . .238480-W . . . . . . . . . . . . . . . . .238490-I . . . . . . . . . . . . . . . . . .238490-IG . . . . . . . . . . . . . . . . .23
8490-IGG . . . . . . . . . . . . . . .238490-IGW . . . . . . . . . . . . . . .238490-R . . . . . . . . . . . . . . . . . .238490-W . . . . . . . . . . . . . . . . .238598-DIN . . . . . . . . . . . . . . .25
54LEVITON MANUFACTURING Co., Inc., 59-25 Little Neck Parkway, Little Neck, New York 11362-2591 www.leviton.com/powerquality
Catalog Number Alphanumeric Index16252-DIN . . . . . . . . . . . . . .2532120-1 . . . . . . . . . . . . . .11, 1232120-DY3 . . . . . . . . . . .11, 1232277-DY3 . . . . . . . . . . .11, 1232347-DY3 . . . . . . . . . . .11, 12
32412-DS3 . . . . . . . . . . .11, 1237120-007 . . . . . . . . . . . . . .5, 637277-007 . . . . . . . . . . . . . .5, 642001-FMC . . . . . . . . . . .11, 1242120-1 . . . . . . . . . . . . . .11, 12
42120-DY3 . . . . . . . . . . .11, 1242277-DY3 . . . . . . . . . . .11, 1242347-DY3 . . . . . . . . . . .11, 1242412-DS3 . . . . . . . . . . .11, 1247120-007 . . . . . . . . . . . . . .5, 6
47120-4X7 . . . . . . . . . . . . . .5, 647277-007 . . . . . . . . . . . . . .5, 647277-4X7 . . . . . . . . . . . . . .5, 647347-007 . . . . . . . . . . . . . .5, 650208-ASA . . . . . . . . . . . . . .15
50240-ASA . . . . . . . . . . . . . .1550240-FAA . . . . . . . . . . . . . .1550240-FMA . . . . . . . . . . . . . .1550240-MSA . . . . . . . . . . . . . .1551005-DIN . . . . . . . . . . . . . .18
51005-WM . . . . . . . . . . . . . .1851010-DIN . . . . . . . . . . . . . .1851010-WM . . . . . . . . . . . . . .1851015-DIN . . . . . . . . . . . . . .1751015-WM . . . . . . . . . . . . . .17
51020-DIN . . . . . . . . . . . . . .1751020-WM . . . . . . . . . . . . . .1751020-WMT . . . . . . . . . . . . .1751110-001 . . . . . . . . . . . . . . .1351110-CT8 . . . . . . . . . . . . . . .13
51110-PTC . . . . . . . . . . . . . . .1351120-1 . . . . . . . . . . . . . . . . .1451120-3 . . . . . . . . . . . . . . . . .1451120-3R . . . . . . . . . . . . . . . .1451120-PTC . . . . . . . . . . . . . . .14
51240-DIN . . . . . . . . . . . . . .1751240-WM . . . . . . . . . . . . . .1752120-7C3 . . . . . . . . . . . . .5, 652120-7M3 . . . . . . . . . . . . .5, 652120-B3 . . . . . . . . . . . . . .9, 10
52120-CM2 . . . . . . . . . . . .9, 1052120-CM3 . . . . . . . . . . . .9, 1052120-M1 . . . . . . . . . . . . .9, 1052120-M2 . . . . . . . . . . . . .9, 1052120-M2H . . . . . . . . . . . .9, 10
52120-M3 . . . . . . . . . . . . .9, 1052220-IM3 . . . . . . . . . . . .9, 1052240-DM3 . . . . . . . . . . . .9, 1052277-7C3 . . . . . . . . . . . . .5, 652277-7M3 . . . . . . . . . . . . .5, 6
52277-CM3 . . . . . . . . . . . .9, 1052277-M3 . . . . . . . . . . . . .9, 1052347-M3 . . . . . . . . . . . . .9, 1052412-DS3 . . . . . . . . . . . .9, 1052480-DM3 . . . . . . . . . . . .9, 10
54175-SSA . . . . . . . . . . . . . . .1655175-ASA . . . . . . . . . . . . . .1655175-SSA . . . . . . . . . . . . . . .1655650-ASA . . . . . . . . . . . . . .1657120-C3S . . . . . . . . . . . . . .7, 8
57120-CM3 . . . . . . . . . . . . .7, 857120-M3 . . . . . . . . . . . . . .7, 857120-M3S . . . . . . . . . . . . .7, 857220-IM3 . . . . . . . . . . . . .7, 857240-DM3 . . . . . . . . . . . . .7, 8
57277-C3S . . . . . . . . . . . . . .7, 857277-CM3 . . . . . . . . . . . . .7, 857277-M3 . . . . . . . . . . . . . .7, 857277-M3S . . . . . . . . . . . . .7, 857346-M3 . . . . . . . . . . . . . .7, 8
57347-M3S . . . . . . . . . . . . .7, 857480-DM3 . . . . . . . . . . . . .7, 857600-DM3 . . . . . . . . . . . . .7, 874120-7M3 . . . . . . . . . . . . .3, 474277-7M3 . . . . . . . . . . . . .3, 4
75120-7M3 . . . . . . . . . . . . .3, 475277-7M3 . . . . . . . . . . . . .3, 4
Notes:
55 LEVITON MANUFACTURING Co., Inc., 59-25 Little Neck Parkway, Little Neck, New York 11362-2591 www.leviton.com/powerquality
Visit Us on the Web
TTo Find: o Find: • Comprehensive Product Information
and Complete PDF Literature Library
• ez-Find™ visit www.leviton.com: it’san advanced web based product search tool with powerful enhancedreporting features
• Tech Support including: IndustryStandards, National Electric CodeUpdates, FAQ’s, NEMA Charts andWiring Diagrams
• Marketing Programs, ApplicationInformation and Product Ideas, TradeShow and Exhibit Schedule, On-LineRegistration for Seminars and Training
• Where To Buy Leviton Products by Zip Code
• A Service Link for AuthorizedResellers to Check Stock, PlaceOrders, and Check Order Status
• Info About Leviton Including PressReleases and Career Opportunities
• How to Contact Leviton withProduct Questions, LiteratureRequests and Comments AboutOur Website!
And Much More...And Much More...
Where can you find a whole line of Pin & Sleeve
IEC 309 Watertight Mechanical Interlocks?
Leviton’s new Industrial Wiring Device Catalog contains thousands of solutions to your everyday-specialized-industrial wiring device needs. ■ For
example, the 29-page Pin & Sleeve Section includes: ■ A complete line ofNorth American Watertight Plugs, Connectors, Receptacles and Inlets, 20 Amp -
100 Amp ■ International Rated Devices, 16 Amp - 125 Amp ■ MechanicalInterlocks fused and non-fused versions 20 Amp -100 Amp ■ Safety Disconnect
Switches fused and non-fused versions 30 Amp - 100 Amp. ■ In other words,Leviton delivers a complete system of IEC 309-1 & IEC-309-2 compliant products
that improve and enhance safety and performance in mission-critical power applications. ■ To obtain a copy of Leviton’s new edition of the Industrial
Wiring Device Catalog, log on to www.leviton.com/industrial/catalog■ Imagine something better…at Leviton we do every day.
An ISO 9001 Registered Quality Manufacturer.©2005 Leviton Manufacturing Co., Inc.
The same place you'll find 3,394 other best-in-quality products that have earned world-class brand recognition.
© Copyright 2005 Leviton Manufacturing Co., Inc. All rights reserved.
C-678A/I5 tp
I-5
Leviton Manufacturing Co., Inc. 59-25 Little Neck Parkway, Little Neck, NY 11362-2591Telephone: 1-800-323-8920 • FAX: 1-800-832-9538Tech Line (8:00AM-7:30PM E.S.T. Monday-Friday): 1-800-824-3005
Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9Telephone: 1-800-469-7890 • FAX: 1-800-563-1853
Leviton S.A. de C.V.General Arista 54-A Col. Argentina, Mexico D.F., C.P. 11270Telephone: 011-525-386-1131, 011-525-386-2052 • FAX: 011-525-386-1797
Visit us on the web at: www.leviton.com