Landt Switchgear Electrical Standard Products Price List

download Landt Switchgear Electrical Standard Products Price List

of 88

description

LNT Switchgear

Transcript of Landt Switchgear Electrical Standard Products Price List

  • VadodaraLarsen & Toubro LimitedSwitchgear Training CentreBehind L&T Knowledge City, Near Village Ankhol, Vadodara - 390 019.Tel: +91 265 245 7805 E-mail : [email protected]

    KolkataLarsen & Toubro LimitedSwitchgear Training Centre4th Floor, 3-B, Shakespeare Sarani, Kolkata: 700071Tel: +91 033 44002151E-mail: [email protected]

    LucknowLarsen & Toubro LimitedSwitchgear Training CentreC-6&7, UPSIDE, P.O. Sarojini Nagar,Lucknow: 226 008.Tel: (0522) 247 6110 / 099355 63239Fax: (0522) 247 6015E-mail : [email protected]

    DelhiLarsen & Toubro LimitedSwitchgear Training Centre32, Shivaji Marg, Near Moti Nagar Metro StationP.O. Box 6223, New Delhi: 110015. Tel: +91 011 41419515 / 41419516 / 41419500Fax: +91 011 41419600E-mail: [email protected]

    CoonoorLarsen & Toubro LimitedSwitchgear Training Centre Ooty-CoonoorMain Road, YellanahalliP.O., The Nilgiris - 643 243.Tel: (0423) 251 7107Fax: (0423) 251 7158E-mail : [email protected]

    , , Vadodara, Delhi & Kolkata

    cover:Low Voltage & Medium Voltage SwitchgearSwitchboard Electrical DesignAC Drives & Building Management SolutionsProtective Relays, Earthing & HarmonicsEnergy Conservation & Management

    PuneLarsen & Toubro LimitedSwitchgear Training CentreT-156/157, MIDC, Bhosari,Pune: 411 026.Tel: (020) 2712 0037 / 2712 0653Fax: (020) 2712 2933E-mail : [email protected]

    New New

    New

  • Description Page No.Contactors 2Bimetal Overload Relays 10Control Accessories 13Motor Protection Circuit Breakers 14Motor Starters 17Digital Soft Starters 20Switch-Disconnector-Fuse Units, SDs & HRC Fuses 22On Load Changeover Switch-Disconnectors 28Moulded Case Circuit Breakers 29Air Circuit Breakers 44Reactive Power Management Solutions 55Digital Protective Relays 61Electronic Metering Devices 65Programmable Logic Controllers (PLC) 68Human Machine Interface 69Modular Devices 71Type 2 co-ordination selection charts for Fuse Protected System 78Discontinued Products 81

  • Please contact the nearest branch office forPrices of the following products :

    l Distribution System Components such as 6kA MCBs, EL + MCB etc.l AC Variable Frequency Drivesl

    l

    l Wires, Cables and Flat Cablesl Busbar Trunking Systemsl

    l

    l Rotary Switchesl Modular Remote Control Units & Indicating Unitsl Til Cable Ducts & LB Series Switchesl Modular Switches and Socketsl Diva Solar Lanternl Medium Voltage AIS upto 36kV

    3 Phase Squirrel Cage Induction Motor Servo & Motion Control Solutions

    Building Automation Products & SolutionsHome Automation Products & Solutions

    ming Devices & Supply Moniters

    L&T, ESP 01.11.2013

    Note: Product photographs shown, are for representative purposes only.

  • Search for 'ProductWhiz' on Google Play and Blackberry Worldor

    Scan this through your mobile to download ProductWhiz now!

  • 3 Pole Power Contactors

    ContactorsPower Contactors

    4 Pole MCXl

    Control Relays (Auxiliary Contactors)

    Definite PurposeContactors

    2

    l MX0 (Mini)l MN0

    Capacitor DutyContactorsl MO C l Single Pole - MR

    l MK1l MU

    L&T, ESP 01.11.2013

    Featuresll Range from 9A 650A AC-3l Entire range is UL listed l Click fit type construction up to 40Al Coil on top design in 95A and abovel Spares available for entire range

    Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

    3 Pole Power Contactors - Type MNX

    Cat. No.M.R.P.

    (`) Per Unit

    1 NO1 NC1 NO1 NC1 NO1 NC1 NO1 NC

    2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC

    ###

    25

    30

    30

    324555558585100100160160160250300350400425650800

    MNX 9

    MNX 12

    MNX 18

    MNX 22

    MNX 25MNX 32MNX 40MNX 45MNX 50MNX 70MNX 80MNX 95MNX 110MNX 140MNX 185MNX 225MNX 265MNX 325MNX 400MNX 550MNX 650

    TypeAC1Rating(A)

    AC3Rating(A)

    Aux.Contacts

    9

    12

    18

    22

    2532404550708095110140185225265325400550650

    Std.Pkg.(Nos.)101010101010101010101011111111111111

    CS94106CS94107CS94108CS94109CS94100CS94101CS94980CS94981CS94110CS94111CS94190ST19000ST19001ST19002ST19003CS94136CS94137CS94138CS94139CS94140CS94142CS94143CS94144CS94145CS96327

    72072081081094594510951095113025104010549555357585932511235133451753023065251452977534180441506914588540

    MNX 22 MNX 40 MNX 80

    MNX 140 MNX 225 MNX 650

    3 Polel MX Power l MNXl MOl MDX (DC Control)l ML

    2 Pole MNXl

    Notes: 1) # Add-on blocks can be ordered separately2) For ordering MNX/MO add-on aux contact blocks, please refer page No. 63) For ordering MNX surge suppressor and MNX/MO MIL kit, please refer page No. 7 4) For Ordering Suffix, please refer page No. 7, Table A 5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.

    Featuresll Range from 9A - 110A AC-3l Compact dimensions saving panel spacel Lug less termination for contactors above 50Al Standardized accessories throughout the rangel Low pick-up VA consumptionl compliant

    Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

    RoHS

    3 Pole Power Contactors - Type MO

    MO 45MO 9 MO 70 MO 110

    Cat. No.M.R.P.

    (`) Per Unit

    TypeAC1Rating(A)

    AC3Rating(A)

    Aux.Contacts

    Std.Pkg.(Nos.)

    MO 9MO 12MO 18MO 25MO 32MO 40MO 45MO 50MO 60MO 70MO 80MO 95MO 110

    91218253240455060708095110

    303540455050506580100125125140

    #############

    10101010101010111111

    CS94564CS94565CS94566CS94567CS94568CS94569CS94570CS94572CS94573CS94574CS94576CS94577CS94578

    695800945132528804345486549105940686585201034012475

  • 33 Pole Power Contactors - Type ML

    Cat. No.M.R.P.

    (`) Per Unit

    TypeAC1Rating(A)

    AC3Rating(A)

    Aux.Contacts

    25324070110200300

    254045100125250400

    2230414061109990157703484037510

    SS91851SS90701SS90721SS90910SS90921SS90935SS91010

    ML 1.5ML 2ML 3ML 4ML 6ML 10ML 12

    2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC

    1111111

    Std.Pkg.(Nos.)

    ML 1.5 ML 6 ML 12ML 3

    3 Pole Power Contactors

    For DC control (Std. Coil Voltage - 24, 110, 220V)20A20A20A20A20A20A

    CS94021CS94022CS94023CS94024CS94025CS94026

    1 NO1 NC1 NO1 NC1 NO1 NC

    101010101010

    M.R.P.(`)

    Per UnitAC1Rating(A)

    Aux.Contact

    Std.Pkg.(Nos.)

    Cat. No.

    For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz)

    MX 06 MX 06 MX 09 MX 09MX 12 MX 12

    Type

    MX 06 MX 06 MX 09 MX 09MX 12 MX 12

    20A20A20A20A20A20A

    6A6A9A9A12A12A

    AC3Rating(A)

    6A6A9A9A12A12A

    CS94012CS94013CS94014CS94015CS94016CS94017

    1 NO1 NC1 NO1 NC1 NO1 NC

    101010101010

    655655690690760760

    9809801030103011251125

    MX 06

    3 Pole Power Contactors - Type MX MiniFeaturesl Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1l Enclosed construction providing compactness and conveniencel Base as well as DIN Rail mounting facilityl Inbuilt Surge Suppressor in MX DC

    Featuresl Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1l Range from 25 - 300A AC-3l Robust and suitable for hostile applications

    Notes:1) For ordering ML/MX add-on aux contact blocks, please refer page No. 62) For ordering MX surge suppressor and MIL kit, please refer page No. 73) For Ordering Suffix, please refer page No. 7, Table A 4) Std. Coil Voltage: ML - 110V, 220V, 240V and 415V, 50Hz

    3 Pole Power Contactors

    Featuresl Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1l Range from 9 - 110A AC-3l Built in surge suppressor for MDX 9 - 38l IP20 connection security for MDX 9 - 38

    Cat. No.M.R.P.

    (`) Per Unit

    TypeAC1Rating(A)

    AC3Rating(A)

    Aux.Contacts

    25283232565690110125125125

    14201500173024304850567079809040110551379514450

    CS96564CS96565CS96566CS96567CS96552CS96553CS96554CS96555CS96556CS96557CS96558

    MDX 9MDX 12MDX 18MDX 25MDX 32MDX 38MDX 50MDX 65MDX 80MDX 95MDX 110

    1 NO1 NO1 NO1 NO#######

    11111111111

    Std.Pkg.(Nos.)

    9121825323850658095110

    MDX 25 MDX 38 MDX 110

    3 Pole (DC Control)

    Power Contactors - Type MDX

    Notes: 1) # Add-on blocks can be ordered separately. 2) For ordering MDX/MNX add-on aux contact blocks, please refer page No. 63) For ordering MDX/MNX surge suppressor and MIL kit, please refer page No. 74) For ordering Suffix, please refer page No. 7, Table A 5) Standard coil voltage: MDX - 24V, 48V, 110V and 220V DC.6) Standard coil voltage: MNX - 110V, 220V, 240V and 415V, 50Hz.

    New

    Featuresll Range from 9A 550A AC-3ll Click fit type construction up to 40Al Coil on top design in 95A and abovel

    Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

    DC ratings available

    Common spares and accessories as MNX 3P

    2 Pole Power Contactors - Type MNX New2 Pole Power Contactors

    Cat. No.M.R.P.

    (`) Per Unit

    1 NO1 NO1 NO1 NO

    ####

    2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC

    ###

    253030324555558585100100160160160250300350400425650

    TypeAC1Rating(A)

    AC3Rating(A)

    Aux.Contacts

    91218222532404550708095110140185225265325400550

    Std.Pkg.(Nos.)101010101010101111111111111

    CS90232CS90234CS90236CS90238CS90240CS90241CS90242CS94060CS94061CS94062CS94063CS94064CS94065CS94066CS94978CS94979CS94067CS94068CS94069CS90243

    MNX 9-2PMNX 12-2PMNX 18-2PMNX 22-2PMNX 25-2PMNX 32-2PMNX 40-2PMNX 45-2PMNX 50-2PMNX 70-2PMNX 80-2PMNX 95-2PMNX 110-2PMNX 140-2PMNX 185-2PMNX 225-2PMNX 265-2PMNX 325-2PMNX 400-2PMNX 550-2P

    5406107108208501885301038454325529065207895939512265161901768521050240753085048500

    L&T, ESP 01.11.2013

  • 4 Pole Power Contactors - Type MCX 4 Pole Power Contactors & AST System ComponentsFeaturesll Range from 16A 800A AC-1l Wide operating band up to 100A AC-1Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1

    Auto Source Transfer Controller

    4

    Control Relays (Auxiliary Contactors)

    810810810810810

    10901090109010901090

    M.R.P.(`)

    Per UnitRatedCurrent Description Cat. No.

    Std.Pkg.(Nos.)

    For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz

    AC-154A

    MX0 40E (4 NO)MX0 31E (3 NO + 1 NC)MX0 22E (2 NO + 2 NC)MX0 13E (1 NO + 3 NC)MX0 04E (4 NC)

    MX0 40E (4 NO)MX0 31E (3 NO + 1 NC)MX0 22E (2 NO + 2 NC)MX0 13E (1 NO + 3 NC)MX0 04E (4 NC)

    CS94018CS94019CS94020CS94041CS94042

    CS94027CS94028CS94029CS94043CS94044

    1010101010

    1010101010

    For DC control std. Coil Voltage - 24, 110, 220V

    AC-154A

    Featuresl

    lll

    Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1Alphanumeric terminal markingsAvailable with AC or DC controlInbuilt Surge Suppressor in MX DC

    Type MX0

    MX0 40E

    Type MN0

    MN0 22E MN0dc 22E

    955955955955955

    15801580158015801580

    M.R.P.(`)

    Per UnitFor AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz

    AC-154A

    MN0 40E (4 NO)MN0 31E (3 NO + 1 NC)MN0 22E (2 NO + 2 NC)MN0 13E (1 NO + 3 NC)MN0 04E (4 NC)

    MN0 40E (4 NO)MN0 31E (3 NO + 1 NC)MN0 22E (2 NO + 2 NC)MN0 13E (1 NO + 3 NC)MN0 04E (4 NC)

    SS94660SS94661SS94662SS94663SS94664

    SS94665SS94666SS94667SS94668SS94669

    1010101010

    1010101010

    For DC control std. Coil Voltage - 24, 110, 220V

    AC-154A

    RatedCurrent Description Cat. No.

    Std.Pkg.(Nos.)

    Notes: 1) For Ordering Suffix, please refer page No. 7, Table A 2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors3) 1 NO + 3 NC, 4 NC add on block combinations are not recommended for MX0 DC Control Contactors. For Example, In MX0 DC control Contactors, 4NO + 4NC combination can be achieved with 2NO + 2NC aux contactor and 2NO + 2NC Add on block and not with 4NO standalone contactor plus 4NC add on block

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)1010101011111111111111111

    AuxContacts

    AC-1Rating(A)

    ##########

    1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC

    1625324050638080100130130160200255325360400500600700800

    Type

    MCX 01MCX 02MCX 03MCX 04MCX 11MCX 12MCX 13MCX 21MCX 22MCX 23MCX 31MCX 32MCX 33MCX 34MCX 41MCX 42MCX 43MCX 44MCX 45MCX 46MCX 47

    Cat. No.

    97510951175183021504265567565156870910010435143951771018975342153711043855545056494077695100150

    CS97009CS97010CS97011CS97012CS97013CS97014CS97015CS97016CS97017CS97018CS97019CS97020CS97021CS97022CS97023CS97024CS97025CS97026CS97027CS97028CS94291

    MCX 22 MCX 34 MCX 47

    Notes:1)

    4) For Ordering Suffix, please refer page No. 7, Table AStd. Coil Voltage: MCX - 220V, 240V and 415V 50Hz

    6) *Ordering Suffix for MCX 21 / 22 / 23; FOOO - 240V AC, ROOO - 415V AC

    # Add on blocks can be ordered separately. 2) For ordering MCX add-on aux contact blocks, please refer page No. 63) For ordering MCX surge suppressor and MIL kit, please refer page No. 7

    5)

    M.R.P.(`)

    Per Unit3979047950

    Type

    AuXC-1000LAuXC-1000

    Cat. No. Std. Pkg.(Nos.) ST80024OOOOST80230OOOO

    11

    Can be used along with MCCBs, & MCX contactors U-POWER Omega ACBs,

    AuXC-1000AuXC-1000L

    4 Pole Mechanically Interlocked Contactors

    5560979012610

    Two MCX 11Two MCX 12Two MCX 13

    111

    ###

    Type

    CS94362CS94365CS94367

    Cat. No.M.R.P.

    (`) Per Unit

    Std. Pkg.(Nos.)

    AuxContacts

    Two MCX 12

    New

    New

    L&T, ESP 01.11.2013

    New

    New

    New

  • Definite Purpose Contactors

    FeaturesWide and chatter free operating bandHigh AC-1 rating for single phase applications

    l l

    Single Pole Contactors - Type MR

    660710725

    M.R.P.(`)

    Per UnitTypeAC3 Rating(A) Cat. No.

    Std. Pkg.(Nos.)

    MR 11WMR 11NWMR 13

    25A25A40A

    CS94176CS94178CS94992

    101040

    Ordering Suffix BOOO - 240V, 50Hz

    MR 11W(Wide band coil)

    MR 11NWSPN (Wide band coil)

    MR 13

    Type MK1

    For Overload Relays type MK1, please refer page No. 11For Ordering Suffix, please refer page No. 7, Table A(For 360V wide band, Ordering Suffix - SOOO)

    M.R.P.(`)

    Per UnitType

    MK 1

    AC3Rating(A)

    Motor Output3 Phase415V, 50Hz Cat. No.Std.Pkg.(Nos.)

    HP7.5

    KW5.515A SS95200 10985

    MK 1

    Type MU

    For Overload Relays type MU refer page No.11For Ordering Suffix please refer page No. 7, Table A

    TypeAC3 Rating(A)

    Cat. No.Std. Pkg.(Nos.)

    MU 1MU 2

    16A25A

    CS94007CS94008

    15252065

    1010

    M.R.P.(`)

    Per Unit

    MU 1 MU 2

    5

    Capacitor Duty Contactors

    FeaturesMO C Range available from 8.5 - 80 KvarDelatching auxiliary contactsEncapsulated resistor assemblySeparate termination for damping resistorsLug less termination for MO C33.5 to MO C80

    compliant

    l l l l l l RoHS

    Capacitor Duty Contactors - Type MO C

    M.R.P.(`)

    Per UnitType

    kVAR Rating@ 415V,3Ph, 50Hz

    Cat. No.Std. Pkg.(Nos.)

    111111111111111111

    Built-inAuxiliaryContacts

    8.5

    12.5

    15

    20

    25

    33.5

    50

    70

    80

    MO C8.5

    MO C12.5

    MO C15

    MO C20

    MO C25

    MO C33.5

    MO C50

    MO C70

    MO C80

    1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC1NO1NC

    CS96320CS96337CS96321CS96338CS90019CS90020CS90021CS90022CS96322CS96339CS96323CS96340CS96324CS96341CS96325CS96342CS96326CS96343

    1740174019551955276027603185318536103610649064909750975011715117151269012690

    Note :1) # Add on blocks can be ordered separately For Add on block Cat No. refer page No. 62) For ordering suffix, please refer page No. 7, Table A3) For ordering spare coils, please refer page No. 8

    MO C25 MO C50 MO C80

    For Reactive Power Management Solutions, please refer page No. 55-59

    L&T, ESP 01.11.2013

  • For MR & MU

    MR 1NO

    Note: Ordering Suffix for Add-on blocks : OOOO

    For ContactorDescription

    ContactsType Cat. No.

    Std. Pkg. (Nos.)

    M.R.P. (`)

    Per Unit1 NO

    1 NO + 1 NC1NC

    CS94179SS94072SS94074

    165150125

    101010

    Add-on Single pole MRMU 1 / MU 2Side mounted auxiliarycontact block

    Front Mounting add-on block

    4 NO3 NO + 1 NC2 NO + 2 NC1 NO + 3 NC

    4 NC2 NO

    1 NO + 1 NC2 NC1 NO1 NC

    CS94112CS94113CS94114CS94115CS94116CS94117CS94118CS94119CS94120CS94121

    400400400400400270270270130130

    400400400400400270270270130130

    305

    525

    630

    170

    CS94594CS94595CS94596CS94597CS94598CS94591CS94592CS94593CS94585CS94586

    CS94033CS94034CS94035CS94036CS94037CS94030CS94031CS94032

    350350350350350225225225

    SS94083SS94084SS94085SS94086SS94087SS94080SS94081SS94082SS94715SS94716

    360360360360360240240240120120

    CS96569

    CS96568

    CS96586

    FrontMounting M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    M.R.P.(`)

    Per UnitMO 9-110MNX 9-40 / MCX 01-23 MDX MX MN0

    Suitable for

    Side Mounting add-on block

    First leftFirst RightSecond LeftSecond right

    1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC

    CS94220CS94221

    400400

    430430430430

    485

    485

    485485485485

    CS94205

    CS94207

    CS94201CS94202CS94203CS94204

    CS94205CS94206CS94207CS94208

    Side Mounting MNX 9-40 / MCX 01-04

    MNX 45-80 / MCX 11-23

    M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    MCX 31-34 MNX 95-650 / MCX 41-47Aux Contact

    Suitable for

    Side Mounting add-on block

    First leftFirst RightSecond LeftSecond right

    1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC1 NO + 1 NC

    CS94580CS94581CS94582CS94583

    400400400400

    400400400400

    ST94985CS94580CS94581CS94582CS94583

    Side Mounting MO 9-110 MO C 8.5-80

    M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    M.R.P.(`)

    Per UnitMDX 9-110Aux Contact

    Suitable for

    Side Mounting add-on block

    LeftRight

    1 NO + 1 NC1 NO + 1 NC

    SS91494 500SS91474 525

    Side Mounting ML 4/6 ML 10/12

    M.R.P.(`)

    Per UnitM.R.P.

    (`) Per Unit

    Aux Contact

    Suitable for

    6

    MNX / MCX Front Add-on Block

    MO Front Add-on Block

    MDX FrontAdd-on Block

    MN0 FrontAdd-on Block

    MX Add-on Block

    Front

    MO/MO C Left Add-on Block

    ML Add-on Block

    Accessories - Add-on Auxiliary Contact Blocks

    MNX/MCX Side Add-on Block

    MDX Add-on Block

    L&T, ESP 01.11.2013

  • 7Accessories - Surge SuppressorsFor MN0

    MN - S1

    MN0 ACMN0 DC

    360360

    SS94623SS94781

    Type Cat. No.M.R.P.

    (`) Per Unit

    Std.Pkg.(Nos.)

    11

    Ordering Suffix 110-240V : BOOO 415V : DOOO

    24-48VDC : 5OOO110-220VDC : 2OOO

    For MX, MNX, MDX & MCX

    MX - S1MNX S1 MNX S3 MNX S4

    Cat. No.M.R.P.

    (`) Per Unit

    For Contactor

    MX 06 to MX 09 / MX 0 ACMNX 9 - 40 / MCX 01 - 04MNX 45 - 80 / MCX 11 - 22MNX 95 - 225 / MCX 31 - 34MNX 265 - 400 / MCX 41 - 44MDX 50 - 110

    CS94039*CS94166*CS94163*

    #CS94164#CS94165

    CS96571**

    34536039513001760360

    Ordering Suffix * 110-240V: BOOO, 415V: DOOO ** : OOOO # 110V: AOOO, 220-240V: BOOO, 360-525V: DOOO

    Mechanical Interlock Kit for MX, MO, MDX, MNX & MCX

    MO MI Kit(MO 9-110)

    MNX M1(MNX 9-40)

    MCX M3(MCX 21-22)

    MX-M1(MX0 / MX06-MX09)

    Cat. No.M.R.P.

    (`) Per Unit

    For Contactor

    MX 06 to MX 09 / MX 0MO 9 - 110*MDX 9 - 38MDX 50 - 110MNX 9 - 40MNX 45 - 80MNX 95 - 140MNX 185 - 225MNX 265 - 650MCX 01 - 04MCX 21 - 22MCX 31 - 34MCX 41 - 47

    34545040012253901570248028303210390248526654320

    CS94038CS94584CS96572CS96573CS94126CS94197CS94198CS94199CS94200CS94126CS93095SS94992CS94301

    * MO MIL Kit contains inbuilt 2 NC Contacts

    MO Spreader Link Kit

    Cat. No.M.R.P.

    (`) Per Unit

    For Contactor

    MO 9 - 45 355CS94274OOOONote: Spreader Link Kit consists of six terminals

    Note: Ordering Suffix for Mechanical Interlock Kits : OOOO

    Accessories - Mechanical Interlock Kits & Spreader Link Kit

    Table AOrdering Suffix for Standard Coil Voltages

    AC Control DC Control*Voltage (V)

    244248110220240360380415440525

    SuffixGOOOHOOOJOOOAOOOKOOOBOOOCOOOLOOODOOOPOOOMOOO

    Voltage (V)2448110220

    Suffix4OOO5OOO1OOO2OOO

    Ordering Suffix for Standard Coil Voltages

    *MX DC has in-built surge suppressor

    Note: * for MX DC, MDX, MX0 DC & MN0 DC

    L&T, ESP 01.11.2013

  • SparesSpare Contact Kit and Spare Coil

    M.R.P.(`)

    Per UnitCat. No. Cat. No. M.R.P.(`)

    Per UnitType

    Spare Contact kit Spare Coil

    MO 9MO 12MO 18MO 25MO 32MO 40MO 45MO 50MO 60MO 70MO 80MO 95MO 110MNX 9MNX 12MNX 18MNX 22MNX 25MNX 32MNX 40MNX 45MNX 50MNX 70MNX 80MNX 95MNX 110MNX 140MNX 185MNX 225MNX 265MNX 325MNX 400MNX 550MNX 650

    MCX 11MCX 12MCX 21MCX 22MCX 31MCX 32MCX 33MCX 34 MCX 41MCX 42MCX 43MCX 44MCX 45MCX 46MCX 47

    MCX 01-04

    CS96380CS96381CS96382CS96383CS96384CS96385CS96386CS96387CS96388CS96389CS96390CS96391CS96392CS94123CS94124CS94125CS94269CS94127CS94128CS94147CS94149CS94150CS94151CS94152CS94153CS94154CS94155CS94156CS94157CS94159CS94160CS94161CS94162CS96336

    -CS94077CS94078CS94330CS94331CS94081CS94082CS94083CS94084CS94295CS94296CS94297CS94298CS94299CS94300

    -

    49063569579515852365274528053155392044655455659049063569571579514852365274528053920513557757355990012215138701671520495263303541047455

    -159025653855444064407885991511170200752547528575336603773542570

    -

    CS96317

    CS96318

    CS96319

    CS94105

    CS94192

    CS94196

    CS94194

    CS94195

    CS94193CS94105CS94009

    ST91291*

    CS94196

    CS94195

    CS94193

    M.R.P.(`)

    Per UnitCat. No.Type

    Combination coil with timer

    ML 2 SS90650 1890

    M.R.P.(`)

    Per UnitCat. No.Type

    Front housing and moving bridge kit

    ML 0ML 1ML 1.5

    ML 2/ ML 3ML 4/ ML 6

    ST28732ST28733ST28734ST23866ST28735

    4004004005501000

    ML Spare Kits

    ML Spare Coils

    MNX Spare Coils MCX Spare Kits

    MNX Spare Kits

    Front housing & Moving bridge kit and Combination coil with timer for ML contactor

    M.R.P.(`)

    Per UnitCat. No. Cat. No. M.R.P.(`)

    Per UnitType

    Spare Contact kit Spare Coil

    MU 1MU 2ML 1.5ML 2ML 3ML 4ML 6ML 10ML 12MN 0 acMN 0 dc

    MR

    CS94010CS94011SS95305SS95307SS95309SS95311SS95313SS95315SS95317

    ---

    CS94009SS90873SS90545

    SS91258

    SS91011SS94191SS94651CS94102

    5809851415221537655875102402009024900

    ---

    440590

    960

    1840

    4025460850350

    Spare Contact Kit and Spare Coil

    8

    Note :1) Ordering Suffix for Spare Contact kit - OOOO2) For Spare Coil Ordering Suffix refer page No. 7, Table A

    440

    1390

    2140

    440

    1390

    2140

    3930

    4515

    14675440440

    1390

    2140

    4515

    14675

    M.R.P.(`)

    Per UnitCat. No.Type

    MO C Spare Coils

    MO C8.5 - 25MO C33.5 - 50MO C70 - 80

    CS96317CS96318CS96319

    44013902140

    * Ordering Suffix for 240V AC - FOOO

    MCX C

    ontac

    tors

    MNX C

    ontac

    tors

    MO Co

    ntacto

    rs

    L&T, ESP 01.11.2013

  • MN 5

    Bimetal Overload Relays

    # For motors with longer starting time (Trip class 30)

    11251125112511251125112511351135113511351155123518151815

    2085238534353560

    622062206220653074958160

    935593559355935593559355

    M.R.P.(`)

    Per UnitRelay Range

    (A) Cat. No.Std.Pkg.(Nos.)

    0.2 - 0.330.3 - 0.5

    0.45 - 0.750.6 - 10.9 - 1.51.4 - 2.32 - 3.33 - 5

    4.5 - 7.56 - 109 - 1514 - 2320 - 3324 - 40

    20 - 3330 - 5045 - 7566 - 110

    42 - 6960 - 10090 - 150135 - 225180 - 300270 - 450

    42 - 6960 - 10090 - 150135 - 225180 - 300340 - 570

    SS94141OOEOSS94141OOGOSS94141OOJOSS94141OOKOSS94141OOMOSS94141OOPOSS94141OOQOSS94141OOSOSS94141OOUOSS94142OOVOSS94142OOBOSS94144OODOSS94145OOEOSS94145OOFO

    MN 5SS94136OOEOSS94136OOGOSS94137OOJOSS94137OOKO

    MN 12SS94138OOHOSS94138OOKOSS94138OOMOSS94138OOPOSS94139OOQOSS94139OORO

    MN 12LSS94127OOHOSS94127OOKOSS94127OOMOSS94127OOPOSS94127OOQOSS94127OOSO

    1010101010101010101010101010

    10101010

    111111

    111111

    MN 2

    (DirectlyOperated)

    Directmounting

    onMNX 9 - 40

    Type of Mounting(Operation)

    #

    Type MN Features

    Available in 3 frame sizes from 0.2-570 AAmbient temperature compensated up to 55 C

    Built in Single Phasing protectionManual and auto reset mode

    l l l l

    FeaturesoAmbient temperature compensated upto 55 C

    Built in Single Phasing protectionManual and auto reset modeFront access to START and STOP/RESET buttonsSealable in OFF condition

    l l l l l

    MN 2 MN 12 MN 12L

    10

    Type RTO

    M.R.P.(`)

    Per UnitType of Mounting(Operation)

    Relay Range(A) Cat. No.

    Std.Pkg.(Nos.)

    (Directly Operated)

    Direct Mounting

    on MO 9 - 45

    101010101010101010101010101010

    0.23 - 0.41 0.31 - 0.55 0.55 - 0.85 0.78 - 1.2 1.2 - 2.0 1.9 - 2.8 2.4 - 3.6 3.5 - 5.2 4.6 - 6.7 6.7 - 9.7 8.5 - 12.5 12.5 - 18.5 17 - 25.5 25 - 37 35 - 45

    CS96355OOFO CS96355OOGO CS96355OOJO CS96355OOLO CS96355OONO CS96355OOPO CS96355OOQO CS96355OOSO CS96355OOTO CS96355OOVO CS96355OOAO CS96356OOCO CS96356OODO CS96356OOEO CS96356OOGO

    127512751275127512751275129012901290129013101400140020602060

    RTO - 1

    Note : 1) MN 5 & MN 12 Relays of lower ratings available on request

    (DirectlyOperated)

    (CT Operated)

    SeparateMounting

    (CT Operated)

    SeparateMounting

    DirectMounting onMNX 45 - 80

    Modular Load FeederRTO Relays can be directly mounted onto MO contactors. This along with the standardized accessories of MO provides you a complete modular feeder solution.

    MPR300MPR301MPR302MPR303MPR304MPR305

    MPR300BE010MPR301BE020MPR302BE040MPR303BE080MPR304BE160MPR305BE320

    570057005700570057005700

    MPR300BB010MPR301BB020MPR302BB040MPR303BB080MPR304BB160MPR305BB320

    570057005700570057005700

    1-2.752-5.54-118-2216-4432-88

    Model Thermal O/L Range M.R.P.(`) Per Unit

    M.R.P.(`)

    Per UnitCat. No. Cat. No.

    Aux. Supply: 240 V AC Aux. Supply: 110 V AC

    Mini Motor Protection RelayFeatures

    Selectable trip class 10A, 10, 20 and 30. In-built CT (1A - 88A) Test facility Protection - Thermal Overload - Single phasing - Current unbalance - Phase sequence reversal

    l lll

    - Locked Rotor - Earth Fault - Under current

    L&T, ESP 01.11.2013

  • Type MX-R0

    MX - R0

    835835835835835835835835835835835835835835

    M.R.P.(`)

    Per UnitType of Mounting(Operation)

    Relay Range(A) Cat. No.

    Std.Pkg.(Nos.)

    0.1 - 0.160.16 - 0.240.22 - 0.330.3 - 0.450.45 - 0.670.67 - 1.01.0 - 1.51.4 - 2.11.8 - 2.72.4 - 3.63.5 - 54.0 - 6.05.5 - 8.58.5 - 12.5

    ST94074OOBOST94074OODOST94074OOEOST94074OOGOST94074OOHOST94074OOKOST94074OOMOST94074OONOST94074OOPOST94074OOQOST94074OOSOST94074OOTOST94074OOUOST94074OOVO

    (DirectlyOperated)

    DirectMounting on

    MX Contactors

    1010101010101010101010101010

    740740740740740740740775815

    Type of Mounting(Operation)

    Relay Range(A) Cat. No.

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    0.6 - 11 - 1.61.5 - 2.52.5 - 44 - 6.56 - 109 - 1411 - 1813 - 22

    SS90035OOKOSS90035OOMOSS90035OOPOSS90035OOROSS90035OOTOSS90035OOVOSS90035OOAOSS90036OOCOSS91888OODO

    101010101010101010

    (DirectlyOperated)

    DirectMounting on

    MK1 Contactors

    Type MK1

    Bimetal Overload Relays

    MK1

    Type MU

    M.R.P.(`)

    Per UnitType of Mounting(Operation)

    Relay Range(A) Cat. No.

    Std.Pkg.(Nos.)

    4 - 6.56 - 10

    9 - 1413 - 2120 - 3228 - 42

    (DirectlyOperated)

    Direct Mounting onMU Contactor

    11

    1111

    MU1990990

    1080115013951650

    SS96557OOTOSS96557OOVO

    SS95979OOAOSS95979OOCOSS95979OOEOSS95979OOFO

    MU2

    MU1 MU2

    11

    Type ML

    1565156515651565156515651565156515651565

    2315231523152315

    M.R.P.(`)

    Per UnitType of Mounting(Operation)

    Relay Range(A) Cat. No.

    Std.Pkg.(Nos.)

    0.15 - 0.250.25 - 0.40.4 - 0.650.6 - 11 - 1.61.5 - 2.52.5 - 44 - 6.56 - 1010 - 16

    9 - 1413 - 2120 - 3228 - 42

    SS91858OODOSS91858OOFOSS91858OOHOSS91858OOKOSS91858OOMOSS91858OOPOSS91858OOROSS91858OOTOSS91858OOVOSS91858OOBO

    SS91859OOAOSS91859OOCOSS91859OOEOSS91859OOFO

    10101010101010101010

    2222

    (DirectlyOperated)

    DirectMounting on

    ML 1.5 Contactors

    ML 2 / ML 3

    ML 1

    ML

    (DirectlyOperated)Direct

    Mounting onML 2/3 Contactors

    L&T, ESP 01.11.2013

  • Separate Mounting Kitfor RTO Relay

    M.R.P.(`)

    Per UnitRTO Relay Separate Mounting Kit 1CS96335OOOO

    Description Cat. No.Std.Pkg.(Nos.)

    190

    TimersElectronic Timers Type ET 100

    Thermal Timers Type GT 200

    Notes: 1) Available till stocks last 2) # 360V tap can be used for 240V connections 3) Ordering Suffix is OOOO

    327532753275

    327532753275

    M.R.P.(`)

    Per UnitDescription

    110 / 240V, 50Hz for3 - 10 secs.9 - 30 secs.36 - 120 secs.

    #240 / 360 / 415V , 50Hz for3 - 10 secs.9 - 30 secs.36 - 120 secs.

    SE92001SE92002SE92003

    SE92005SE92006SE92007

    Cat. No.StdPkg.(Nos.)

    111

    111

    ET 100 GT 200

    2480

    M.R.P.(`)

    Per UnitDescription

    Operating Voltages:230 / 250V, 360V, 400 / 440V, 500V,50 Hz for 5 - 18 secs. range

    SS91270 1

    StdPkg.(Nos.)

    Cat. No.

    Voltage (V)250V320V360V380V

    400 / 440V

    NOOOROOOCOOOLOOOPOOO

    SuffixOrdering Suffix for GT 200 Timer

    12

    Note: ST 100 supplied with Mounting Kit, suitable for ET 100 replacement. For Complete range of Timing Devices, please refer the Panel Accessories Price List

    Accessories for Bimetal Overload Relays

    Accessories for Bimetal Overload Relays

    Kit for Mounting MN5 Relay Din Rail Mounting KitMN2 Relay

    Relay Reset Cord for MN2 Relay

    M.R.P.(`)

    Per UnitMN2 Relay reset cord - 400mmMN2 Relay reset cord - 650mmMN2 Relay reset cord - 900mmMN2 Relay reset cord - 1200mm

    1111

    SB94207OOOOSB94208OOOOSB94209OOOOSB94210OOOO

    Description Cat. No.Std.Pkg.(Nos.)

    515540590665

    400 mm 650 mm 900 mm 1200 mmRelay Mounting Kit

    130

    130

    190

    145

    185

    100

    M.R.P.(`)

    Per UnitDescription Cat. No.

    Std.Pkg.(Nos.)

    Push button unit for MK 1 / ML RelaysPush button extn. unit for MN 2 RelaysKit for Mounting MN 2 Relay onML 1.5 contactorKit for Mounting MN 2 Relay separately (Direct Mounting Type)Kit for Mounting MN 5 Relay onMNX 95 / 110 / 140 contactorKit for Mounting MN 5 Relay onML 2 / ML 3 contactorKit for Mounting MN5 Relay onML 4 / ML 6 contactorDIN Rail Mounting Kit Relay onMN 2 Relay

    SS90004SS94968SS94701

    SS94700

    SS94638

    SS94151

    SS94152

    SS91887

    110050

    50

    20

    20

    20

    50

    12035

    Electronic Timers Type ST 100

    14401440

    M.R.P.(`)

    Per UnitDescription

    240 / 360 / 415V, 50Hz for3 - 30 secs.12 - 120 secs.

    ST80328OOOOST80329OOOO

    Cat. No.StdPkg.(Nos.)

    11

    ST 100

    New

    L&T, ESP 01.11.2013

  • Push Button Pendants6A, 415V, 50 Hz

    Actuator Units Type TK36A, 415V, 50 Hz (Suitable for 30.5mm Cutout Dia.)

    Control Accessories

    StdPkg.(Nos.)

    M.R.P.(`)

    Per UnitDescription

    Selector actuator - 2 position(black only)Selector actuator - 3 position(black only)Mushroom push button actuator(red, green or black)Shrouded push button actuator(red, black, green, yellow, blueor grey)Unshrouded push button actuator(red, black, green, yellow, blueor grey)

    Key actuator - lockable in 1 position

    Key actuator - lockable in bothpositionsElement with 2 fixing screws

    SS91516

    SS91517

    SS91518

    SS91519

    SS91520

    SS91522 *

    SS91521 *

    SS90375 *

    Cat. No.

    440

    440

    270

    195

    195

    600

    600

    220

    30

    30

    30

    30

    30

    30

    30

    100

    Ordering Suffix for ColourBlackRedGreenYellowBlueGrey*

    OAOOOBOOOCOOODOOOEOOOFOOOOOO

    102519052560

    M.R.P.(`)

    Per UnitStdPkg.(Nos.)

    Description

    With 2 push buttonsWith 4 push buttonsWith 6 push buttons

    SS90502SS90504SS90506

    303030

    Cat. No.

    Ordering Suffix is OOOO

    To order Control Accessories, please specify Type, Cat no. & Ordering Suffix for color

    1113

    For Timing, Control Devices and Supply Monitors from GIC and 22.5 mm dia Range of Modular Remote Control & Indicating Units from ESBEE, please refer Panel Accessories Price List.

    TM

    SDz5Sz5

    SDz5, SPPR + Timer, 360VSDz5, SPPR + Timer, 415VSingle Phase Preventor Relay - Sz5380V AC (6 wires) Single Phase PreventorRelay - Sz5 380V AC (7 wires)

    XM81808OOOOXM81809OOOO

    CS94824LOOO

    ST92166OOOO

    11

    1

    1

    18451845

    630

    630

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Description Cat. No.

    Single Phase Preventor Relay

    L&T, ESP 01.11.2013

    New

  • Motor Protection Circuit Breakers

    Type MOG-H1M (Rotary Type) - Frame 1 With short circuit protection only

    Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    0.160.250.400.631.001.602.504.006.3010.0013.0016.0020.0025.0032.00

    -0.060.090.120.250.550.751.502.204.005.407.509.0012.5015.00

    2.13.35.28.21320.832.55281.9130169208260325416

    ST41923OOOOST41924OOOOST41925OOOOST41926OOOOST41927OOOOST41928OOOOST41929OOOOST41930OOOOST41931OOOOST41932OOOOST41933OOOOST41934OOOOST41935OOOOST41936OOOOST41937OOOO

    111111111111111

    Short Circuit Release

    (A)

    Recommended Motor Ratingat 415V, 3-Ph, 50Hz (KW)

    Cat. No.Rating(A)

    2190 2190 2190 2940 2940 2940 2940 3100 31003205 3330 3385 3625 4385 6015

    M.R.P.(`)

    Per UnitRating(A)

    Std.Pkg.(Nos.)

    Cat. No.

    ST41889OOOOST41890OOOOST41891OOOOST41892OOOOST41893OOOOST41894OOOOST41895OOOOST41896OOOOST41897OOOOST41898OOOOST41899OOOO

    0.1 - 0.160.16 - 0.250.25 - 0.400.40 - 0.630.63 - 1.001.00 - 1.601.60 - 2.502.50 - 4.004.00 - 6.306.30 - 10.009.00 - 13.00

    Recommended Motor Ratingat 415V, 3-Ph, 50Hz (KW)

    ThermalReleaserange(A)

    0.160.250.400.631.001.602.504.006.3010.0013.00

    -0.060.090.120.250.550.751.502.204.005.40

    11111111111

    Breaking capacity : Icu = 100 kA upto 10A & Icu = 50 kA for 13A

    2340 2340 2340 2445 2445 2505 2505 2570 258525852855

    Type MOG-S1 (Rocker Type) (ROM cannot be fitted with MOG - S1) With short circuit & overload protection

    14

    Procedure for selecting the appropriate model:

    For applications in a single-phasecircuit, connect the 3-poles in series

    Same characteristics as desired for a standard thermal overload relay

    Long-time operating type or quick operating type thermal overload relay desired

    Confirm the motor full load current

    Three-phase load Single-phase load

    Select the rated current of MPCB

    Select the branch circuit cable & confirm the control panel specifications

    Confirm the short-circuit current of the circuit

    Select the operating characteristics

    Instantaneous trip type MPCBMOG-H1M, MOG-H2M

    /

    Adjustable thermal magnetic trip type MPCBMOG-S1, MOH-H1, MOG-H2

    Note: Please contact the nearest branch office for fuseless type 2 co-ordination selection chart.

    FeaturesWith compactness MPCB provides high-performance short-circuit current breakingWide range of current adjustment dial for optimum protectionStand-alone motor protectionWith Single phasing protectionAll accessories are common for both frames and separate short circuit alarm is also availablePadlocking features available on MPCB rotary knob and rocker type

    l l l l l l

    L&T, ESP 01.11.2013

  • Type MOG-H1 (Rotary T ype) - Frame 1

    Breaking capacity : Icu = 100 kA upto 13A & Icu = 50 kA 16A - 32Afrom

    M.R.P.(`)

    Per UnitST41904OOOOST41905OOOOST41906OOOOST41907OOOOST41908OOOOST41909OOOOST41910OOOOST41911OOOOST41912OOOOST41913OOOOST41914OOOOST41915OOOOST41916OOOOST41917OOOOST41918OOOO

    Std.Pkg.(Nos.)

    Rating(A) Cat. No.

    Recommended Motor Ratingat 415V, 3-Ph, 50Hz (KW)

    ThermalReleaserange(A)

    0.1 - 0.160.16 - 0.250.25 - 0.400.40 - 0.630.63 - 1.001.00 - 1.601.60 - 2.502.50 - 4.004.00 - 6.306.30 - 10.009.00 - 13.0011.00 - 16.0014.00 - 20.0019.00 - 25.0024.00 - 32.00

    111111111111111

    0.160.250.400.631.001.602.504.006.3010.0013.0016.0020.0025.0032.00

    -0.060.090.120.250.550.751.502.204.005.407.509.0012.5015.00

    2750 2885 2885 3105 3105 311031103170 32303330 3620 4000 4315 4695 7325

    Motor Protection Circuit BreakersWith short circuit & overload protection

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Cat. No.Description

    Auxiliary Contact Front mtg. 1NOAuxiliary Contact Front mtg. 1NCAuxiliary Contact Left side mtg. 2NOAuxiliary Contact Left side mtg. 1NO + 1NCAuxiliary Contact Left side mtg. 2NCTrip Alarm Contact Front mtg. 1NOTrip Alarm Contact Front mtg. 1NCAuxiliary + Alarm Left side mtg. 2NOShort circuit alarm Left side mtg. 1NO + 1NCShunt trip 24V DCShunt trip 110V, 50HzShunt trip 230V, 50HzUnder Voltage release, 110V, 50HzUnder Voltage release, 415V, 50HzExternal operating handle, (Black) Frame 1External operating handle, (Black) Frame 2

    ST41942OOOOST41943OOOOST41944OOOOST41945OOOOST41946OOOOST41947OOOOST41948OOOOST41949OOOOST41950OOOOST41951OOOOST41952OOOOST42952OOOOST41953OOOOST41954OOOOST41955OOOOST41956OOOO

    10101111010111111111

    480 480 590590575 765 765 815 815 1330 1400 1400 1400 1400 1050 1050

    Type MOG-H2 (Rotary Type) - Frame 2

    M.R.P.(`)

    Per Unit32.0040.0050.0063.00

    ST41919OOOOST41920OOOOST41921OOOOST41922OOOO

    Std.Pkg.(Nos.)

    Rating(A)

    Recommended Motor Ratingat 415V, 3-Ph, 50Hz (KW)

    ThermalReleaserange(A)

    Cat. No.

    1111

    24.00 - 32.0028.00 - 40.0035.00 - 50.0045.00 - 63.00

    15.0020.0025.0034.00

    Breaking capacity: Icu = 50kA 32A - 63Afrom

    9470959010540 11220

    Type MOG-H2M (Rotary Type) - Frame 2

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    32.0040.0050.0063.00

    15.0020.0025.0034.00

    416520650819

    ST41938OOOOST41939OOOOST41940OOOOST41941OOOO

    1111

    Short Circuit Release

    (A)

    Recommended Motor Ratingat 415V, 3-Ph, 50Hz (KW)

    Cat. No.Rating(A)

    7730 7730 9430 9430

    Breaking capacity: Icu = 50kA from 32A - 63A

    With short circuit protection only

    With short circuit & overload protection

    15

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Cat. No.Description

    ST41957OOOOST41958OOOOST41959OOOOST41960OOOOST41961OOOOST41962OOOOST41963OOOOST41964OOOOST41966OOOOST41967OOOOST41968OOOOST41969OOOOST41970OOOOST41971OOOOST41972OOOOST41973OOOOST41965OOOOST41974OOOOST41975OOOOST41976OOOO

    5555555511111111111010

    590650705765690750805865108012301480118013301580138015306901195300325

    2 MPCB 45 mm width w/o acc3 MPCB 45 mm width w/o acc4 MPCB 45 mm width w/o acc5 MPCB 45 mm width w/o acc2 MPCB 45 mm width with one acc 9 mm3 MPCB 45 mm width with one acc 9 mm4 MPCB 45 mm width with one acc 9 mm5 MPCB 45 mm width with one acc 9 mm2 MPCB 55 mm width w/o acc3 MPCB 55 mm width w/o acc4 MPCB 55 mm width w/o acc2 MPCB 55 mm width with one acc 9 mm3 MPCB 55 mm width with one acc 9 mm4 MPCB 55 mm width with one acc 9 mm2 MPCB 55 mm width with two acc 18 mm4 MPCB 55 mm width with two acc 18 mmFeed in terminal for 45 mm width BusbarFeed in terminal for 55 mm width BusbarBus bar safety cover 45 mm width BusbarBus bar safety cover 55 mm width Busbar

    Connecting Busbar link

    3 Phase Feed in terminal Busbar SafetyCover

    Accessories for MOG

    Short Circuit Alarm Auxiliary + Alarm External Operating Handle Shunt Trip

    Connecting Busbar link

    L&T, ESP 01.11.2013

  • Motor Startersin Sheet-Steel Enclosure Type MF, MK, MU & MB(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    Direct-on-Line Starters

    Description

    SS97210SS96210SS96211SS96228SS95647SS95649SS95648SS95650

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-PhHP kW

    RelayMax.Range(A)

    5.55.55.55.57.57.511.011.0

    7.57.57.57.510.010.015.0.15.0

    9 - 159 - 1411 - 1813 - 2213 - 2114 - 2320 - 3220 - 33

    MF1MK1 DOLMK1 DOLMK1 DOLMU1 DOL # MB1 DOL #MU2 DOL #MB2 DOL #

    11111111

    Cat. No.Std.Pkg.(Nos.)

    11001810185018953070309041304150

    MF1 3-Ph MK1 MB1

    Direct-on-Line Startersin Sheet-Steel Enclosure Type MN with Single Phase Protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    Description

    SS94351SS94352SS94353SS94017SS94018

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Cat. No.

    10.015.020.030.045.0

    7.511.015.022.533.5

    9 - 1514 - 2320 - 3330 - 5045 - 75

    MN 16 DOLMN 25 DOLMN 32 DOLMN 45 DOLMN 65 DOL

    11111

    Std.Pkg.(Nos.)

    2900443571501223516755

    Description

    SS91854SS90702SS90722

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Cat. No.

    15.020.030.0

    11.015.022.5

    20 - 3220 - 3228 - 42

    ML 1.5 DOLML 2 DOLML 3 DOL

    111

    Std.Pkg.(Nos.)

    4500749512750

    MN 16 MN 45

    Semi-Automatic Star-Delta Startersin Sheet-Steel Enclosure Type MK, MU & MB(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    SS96255SS96258SS96260SS95891SS95895SS95893SS95897

    MK1 SASDMK1 SASDMK1 SASDMU1 SASD # MB1 SASD #MU2 SASD # MB2 SASD #

    9 - 1411 - 1813 - 2213 - 2114 - 2320 - 3220 - 33

    9.311.011.011.011.022.522.5

    12.515.015.015.015.030.030.0

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-PhHP kW

    RelayMax.Range(A)

    Description Cat. No.

    1111111

    Std.Pkg.(Nos.)

    594059655985793589051003010540

    MU 1S MB 2SMK 1S

    Semi-Automatic Star-Delta Startersin Sheet-Steel Enclosure Type ML(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    SS91856SS90707

    ML1.5 SASDML2 SASD

    13 - 2120 - 32

    18.526.0

    25.035.0

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.Std.Pkg.(Nos.)

    11

    1035518100

    Single Phase Starters

    M.R.P.(`)

    Per Unit0.51.02.03.0

    0.370.751.52.2

    4 - 6.56 - 10

    10.5 - 17.512 - 20

    MH0 (Coil operated)MH0 (Coil operated)

    MF1MF1

    1111

    Cat. No.DescriptionRelayMax.Range(A)

    Max. MotorOutput at230V, 1-Ph

    HP kW

    Std.Pkg.(Nos.)

    950950820820

    MF1 1-Ph MH0

    ST37491BOTOST37491BOVOSS97227OOBOSS97227OOCO

    Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors 2) For Ordering Suffix please refer table C page No. 19

    17

    ML 3

    Direct-on-Line Startersin Sheet-Steel Enclosure Type ML(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    L&T, ESP 01.11.2013

    ML 2S

    For lower relay ranges, please refer Agricultural Electrical Products' price list.

    For lower relay ranges, please refer Agricultural Electrical Products' price list.

  • Fully Automatic Star-Delta Starters

    SS94362SS94364SS94366SS94021SS94022SS94705SS94706SS94707

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.

    11111111

    MN 16 FASDMN 25 FASDMN 32 FASDMN 45 FASDMN 65 FASDMN 80 FASDMN 110 FASDMN 140 FASD

    9 - 1514 - 2320 - 3330 - 5045 - 7545 - 7566 - 11090 - 150

    15.025.035.050.075.090.0125.0175.0

    Std.Pkg.(Nos.)

    976510920179652885047815522706841071615

    11.018.526.037.555.067.090.0

    130.0

    in Sheet-Steel Enclosure Type MN with Single Phase Protection feature(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)

    Motor Starters

    Fully-Automatic Star-Delta Starters

    SS96254SS96257SS96259SS95890SS95894SS95892SS95896

    MK1 FASDMK1 FASDMK1 FASDMU1 FASD # MB1 FASD #MU2 FASD #MB2 FASD #

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.

    12.515.015.015.015.030.030.0

    9.311.011.011.011.022.522.5

    9 - 1411 - 1813 - 2213 - 2114 - 2320 - 3220 - 33

    1111111

    Std.Pkg.(Nos.)

    674568056830919092301107011170

    SS91855SS90705SS90730SS90913SS90923SS90938SS91019

    ML1.5 FASDML2 FASDML3 FASDML4 FASDML6 FASDML10 FASDML12 FASD

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.

    1111111

    25.035.050.075.0125.0250.0400.0

    18.526.037.555.090.0180.0300.0

    13 - 2120 - 3228 - 4245 - 7566 - 110135 - 225180 - 300

    Std.Pkg.(Nos.)

    1175518660307455268086370136710154850

    MB 1F MU 2FMK 1F

    ML 2F ML 1.5F

    in Sheet-Steel Enclosure Type MK, ML, MU & MB(Motor Rating AC-3 Duty, 415V, 50Hz, 3Ph)

    Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors 2) For Ordering Suffix please refer table C page No. 1918

    MN 16F

    Spares for MK1 Starters

    M.R.P.(`)

    Per UnitSingle Moving ContactStd. Operating coils400 / 440V, 50Hz360V, 50Hz320V, 50Hz230V, 50Hz220V, 50Hz110V, 50HzAuxiliary contact block: 1 NO + 1 NCSpare kit without coilThermal timer without combination coilCombination coilsCombination coils for 400 / 440V, 50HzCombination coils for 230V, 50HzCombination coils for 380V, 50HzCombination coils for 360V, 50HzPush Button UnitArc ShieldContact bridge without Contacts

    SS91009

    SS90047SS90165SS90166SS90045SS90044SS90043SS90120SS90983SS90224

    SS90443SS90444SS90445SS90446SS90004SS50004SS50005

    Std.Pkg.(Nos.)

    Description Cat. No.

    10

    10101010101050501

    10101010111

    40

    200200200200200200275450780

    510510510510120130120

    Aux contact block

    Push button unit

    Combination coil

    Spare coil

    Spares for MN StartersM.R.P.

    (`) Per Unit

    Description Cat. No.Std.Pkg.(Nos.)

    Bracket for Mounting cont. MNX 25 - 32 SS94030OOOO 20100

    Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1Sheet steel enclosures with IP 54 protectionWide range of relay settings and coil voltagesStandardized accessories and spares available

    Salient Features and Benefits of Startersl

    l

    l

    l

    For lower relay ranges, please refer Agricultural Electrical Products' price list.

    L&T, ESP 01.11.2013

  • Ordering Suffix for MK1/MU/MB/ML & MN StartersTable C

    Coil VoltagesB - 240 VC - 360 VD - 415 VP - 440 V

    Realay Range (A)MK1 MU MB ML MN

    A : 9 - 14C : 11 - 18D : 13 - 22M : 1 - 1.6P : 1.5 - 2.5R : 2.5 - 4T : 4 - 6.5V : 6 - 10

    A : 9 - 14C : 13 - 21E : 20 - 32

    B : 9 - 15D : 14 - 23E : 20 - 33

    A : 9 - 14B : 10 - 16C : 13 - 21E : 20 - 32F : 28 - 42G : 30 - 50J : 45 - 75K : 66 - 110M : 90 - 150P : 135 - 225Q : 180 - 310R : 2.5 - 4T : 13 - 21

    B : 9 - 15D : 14 - 23E : 20 - 33G : 30 - 50J : 45 - 75K : 66 - 110Q : 2 - 3.3S : 3 - 5U : 4.5 - 7.5V : 6 - 10

    Submersible Pump Controllers

    19

    Submersible Pump ControllerIn Sheet Enclosure Type MU - G(Motor Rating AC-3 Duty, 415V, 50Hz, 3 phase)

    111

    61010

    9 - 14 13 - 2128 - 42

    SS97756SS95983SS95974

    500059406920

    MU - G6 MU - G10

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.Std.Pkg.(Nos.)

    MU - G6 DOL Starter *MU - G10 DOL Starter * MU - G10H DOL Starter *

    4.57.57.5

    Submersible Pump ControllerIn Sheet Enclosure Type MU-G(Motor Rating AC-3 Duty, 415V, 50 Hz, 3 phase)

    MU-G20 MU-G50 MU-G75

    Submersible Pump ControllerIn Sheet Steel Enclosure Type MR-G, MF-G

    MR-G2 MF-G1

    Note: For dual meter (Ammeter + Voltmeter) version - Add (`) 210* Also available with lower Relay Ranges

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at230V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.Std.Pkg.(Nos.)

    336036704055424545402255235024352480

    111111111

    Type MR-G2 *For Single Phase Motors

    Type MF-G1 *For Single Phase Motors

    0.51.01.52.03.00.51.01.52.0

    6 - 109 - 14 11 - 1813 - 2213 - 226.5 - 1112 - 2012 - 2012 - 20

    SS96988SS96560SS96989SS96990SS97725SS97734SS97736SS97737SS97738

    0.370.751.11.52.20.370.751.11.5

    M-POWER - Module for Mobile Starter

    GSM0301OOOO

    Cat. No.M.R.P.

    (`) Per Unit

    5950

    Description

    Module for Mobile Starter & Submersible Controllers

    Std.Pkg.(Nos.)

    1

    Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1Protections Offered - Overload, Single Phasing, Phase reversal, Phase imbalanceAuto Restart FeatureVibration proof enclosure with IP54 protection classIndications Offered - ON/OFF, Voltage and AmpereCompatible with M-POWER

    Salient Features and Benefits of Submersible Pump Controllerll

    llll

    New

    * For lower relay ranges, please refer Agricultural Electrical Products' price list.

    * For lower relay ranges, please refer Agricultural Electrical Products' price list.

    1

    1

    1

    1

    15

    20

    20

    30

    9 - 14

    28 - 42

    13 - 21

    30 - 50

    MU-G15 Fully Automatic Star - Delta Starter*

    MU-G20 Fully Automatic Star - Delta Starter*

    MU-G20 Fully Automatic Star - Delta Starter*

    CS94091

    SS95975

    SS95984

    CS96008

    9700

    11450

    14100

    22850

    36160

    49000

    M.R.P.(`)

    Per Unit

    Max. MotorOutput at415V, 3-Ph

    HP kW

    RelayMax.Range(A)

    Description Cat. No.Std.Pkg.(Nos.)

    11

    15

    15

    22.5 MU-G30 Fully Automatic Star - Delta Starter*1

    1

    50

    75

    45 - 75

    66 - 110

    MU-G50 Fully Automatic Star - Delta Starter*MU-G75 Fully Automatic Star - Delta Starter*

    CS96009

    CS96451

    37.5

    101

    New

    New

    L&T, ESP 01.11.2013

  • Digital Soft StartersEMX3 Soft Starters

    20

    # Note : The above EMX3 current ratings are based on 300% starting current,10 starts per hour, 10 seconds starting time and ambient temperature of 45C.For proper sizing of soft starter based on the application parameters please useWinstart Software. For Winstart software please contact Customer Interaction Centre.

    EMX3-0023B-411EMX3-0043B-411EMX3-0053B-411EMX3-0076B-411EMX3-0097B-411EMX3-0105B-411EMX3-0145B-411EMX3-0170B-411EMX3-0220B-411EMX3-0255C-411EMX3-0360C-411EMX3-0430C-411EMX3-0620C-411EMX3-0650C-411EMX3-0790C-411EMX3-0930C-411EMX3-1200C-411EMX3-1410C-411EMX3-1600C-411

    68200732008540091400100000116000134000152000168000177000188000285000293000310000378000475000732000878000970000

    2343537697105145170220255360400620650790930120014101600

    34647911414515721725533038254064593097511851395180021152400

    Built - In

    EMX3 Cat. No.M.R.P.

    (`) Per Unit

    Bypass Contactor

    Suitable for Motor with #Rated Current in Amps

    3 Wire (Inline

    Connection) 6 Wire

    (Inside Delta Connection)

    EMX3 Soft Starters : For Heavy Duty Applications Ratings from 23 to 1600A Control Voltage from 94VAC to 484VAC Constant current XLR-8 Adaptive acceleration control for pumps Kickstart XLR-8 Adaptive deceleration control for pumps Forward / Reverse Jog Comprehensive motor protection Large LCD Keypad Auto Start / stop 2 motor data sets Fully programmable overload trip 5 digital inputs, 4 digital outputs, 1 analog output

    Built-in RTD & Thermistor inputs 99 event logs with time stamping Starter communication timeout Network communication trip Auto detection of inline or inside delta power connection

    Programmable auto start/stop 24 VDC auxiliary power supply Power through operation allows to run soft starter even with one SCR shorted

    Emergency run operation I/O expansion card (optional)

    EMX3-0255B-411EMX3-0350B-411EMX3-0425B-411EMX3-0500B-411EMX3-0580B-411EMX3-0700B-411EMX3-0820B-411EMX3-0920B-411EMX3-1000B-411

    245000298000352000380000443000499000562000658000719000

    2553504255005807008209201000

    3825256387508701050123013801500

    EMX3 Cat. No.M.R.P.

    (`) Per Unit

    Bypass Contactor

    Suitable for Motor with #Rated Current in Amps

    3 Wire (Inline

    Connection) 6 Wire

    (Inside Delta Connection)

    Terminals for connecting External contactor (AC1 duty)

    * All protections remain active during bypass operation

    Built - In

    New

    We recommend the use of :1. Line Contactor : This will isolate and protect the soft starter SCR's

    from any voltage transient while it's not in operation.2. Bypass Contactor (For models without built-in bypass) : This will

    bypass and protect the soft starter SCR's while in running state from Current and Voltage transient's.

    3. Semiconductor fuses : This will protect the starter SCR's during starting and stopping states from current transient's and excess IT.

    Ordering Information for EMX3 Soft Starter

    Keypad1 = with keypadControl voltage1 = 110-210 VAC & 220-440 VACMains voltage4 = 200 ~ 440 VACBypassB = Internally BypassedC = Non-Bypassed(External contactor required)Nominal current rating0023 - 23A..1600 - 1600A

    E M X 3

    L&T, ESP 01.11.2013

  • Digital Soft StartersCSX Soft Starters

    M.R.P.(`)

    Per UnitMotorkW Cat. No.

    CSXi Soft Starters

    M.R.P.(`)

    Per UnitMotorkW Cat. No.

    21

    Note : The above CSX & CSXi ratings are based on 400% starting current, 10 starts per hour up to 30kW & 6 starts per hour for 37kW & above, 6 seconds starting time and ambient temperature of 45C.For proper sizing of soft starter based on the application parameters please use Winstart Software.

    CSX Soft Starters : For Standard Applications Inbuilt Bypass Contactor Soft Start / Soft Stop Compact Complements existing motor protection Truly plug & play Communication options available

    CSXi Soft Starters : For standard applications Inbuilt Bypass Contactor Soft start / Soft stop / Adjustable current limit Essential motor protections against

    OverloadSingle phasingInstantaneous overcurrentPhase sequence reversalAbnormality in supplyUnbalanced current

    Thermistor protection through PTC Excess start time setting Communication options available PC Interface as optional

    Optional Modules/Cards for CSX / CSXi / EMX3

    Cat. No.M.R.P.

    (`) Per Unit

    Description

    Modbus InterfaceProfibus InterfaceDeviceNet InterfaceUSB InterfaceModbus TCP ModuleEthernet IP ModuleProfinet ModuleEMX3 RTD/Ground Fault Expansion CardEMX3 I/O Expansion Card

    PIM-MB-01PIM-PB-01PIM-DN-01PIM-USB-01PIM-MT-01PIM-EI-01PIM-PN-01

    995-04804-00995-04803-00

    13000210001700080004000044000440001700010000

    We recommend the use of :1. Line Contactor : This will isolate and protect the soft starter SCR's

    from any voltage transient while it's not in operation.2. Bypass Contactor (For models without built-in bypass) : This will

    bypass and protect the soft starter SCR's while in running state from Current and Voltage transient's.

    3. Semiconductor fuses : This will protect the starter SCR's during starting and stopping states from current transient's and excess IT.

    7.5151822303745557590110

    CSX-007-41CSX-015-41CSX-018-41CSX-022-41CSX-030-41CSX-037-41CSX-045-41CSX-055-41CSX-075-41CSX-090-41CSX-110-41

    2860030300314003710041800479005450059400809008800097000

    7.5151822303745557590110

    CSXi-007-41CSXi-015-41CSXi-018-41CSXi-022-41CSXi-030-41CSXi-037-41CSXi-045-41CSXi-055-41CSXi-075-41CSXi-090-41CSXi-110-41

    4150048100505005390060000657007920086700101000127000141000

    Ordering Information for CSX Series Soft Starter

    Control Voltage1 = 110 VAC & 220-440 VACMains voltage4 = 200 ~ 440 VACNormal kW rating @ 400VAC007 7.5 kW..110 110 kWMotor protectionBlank (no space) - Without motor protectioni - With motor protection

    C S X

    L&T, ESP 01.11.2013

  • 149020954235533559907875962511910143402311025070

    M.R.P.(`)

    Per UnitFN 32 TPFN 63 TPFN 100 TPFN 125 TPFN 160 TPFN 200 TPFN 250 TPFN 315 TPFN 400 TPFN 630 TPFN 800 TP

    Type Cat. No.

    ST27892ST27893ST30287ST27894SK95998ST27895ST31731ST27897ST27898ST27899ST27900

    Switch-Disconnector-Fuse Units

    22

    Type FN S-D-F suitable for DIN fuse-link (TPN)

    Range 32A to 800A, 415V, AC 23A2P / TP / TPN VersionsSuitable for cylindrical / DIN / Bolted fuse-linkAvailable in interior / Sheet steel enclosure versionConforms to Door interlock & padlock facility

    Features offered by FN S-D-Flllll IEC 60947-3, IS/IEC 60947-3l

    CE handle has door interlock facility without defeat feature* Spare cat no. ST97895OOOO is of Interior FN 250 SDF suitable for Sheet steel enclosure

    FN in SS EnclosureFN - TPN (Open Execution)

    M.R.P.(`)

    Per UnitM.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Std.Pkg.(Nos.)

    Cat. No.Cat. No.Type TypeTypeRange(A)Rated Current(A)

    16051440220519504545597065408315996012430148352398026015

    708083808985118051362516155188503021032730

    111111111

    1111111111111

    SK95569SK95005SK95715SK95511SK95681SK95514SK95515SK95547SK95705

    FN 100 TPNFN 125 TPNFN 160 TPNFN 200 TPNFN 250 TPNFN 315 TPNFN 400 TPNFN 630 TPNFN 800 TPN

    SK95518SK95703*SK95421SK95704*SK95568SK95001SK95713SK95418SK95642SK95461SK95481SK95521SK95679

    FN 32 TPN / FPFN 32 TPN / FP CE*FN 63 TPN / FP

    FN 63 TPN / FP CE*FN 100 TPNFN 125 TPNFN 160 TPNFN 200 TPNFN 250 TPNFN 315 TPNFN 400 TPNFN 630 TPNFN 800 TPN

    2 to 322 to 322 to 632 to 63

    63 to 10063 to 12563 to 16080 to 200125 to 250125 to 315200 to 400315 to 630315 to 800

    HFHFHFHF

    HN Size 000/00HN Size 000/00HN Size 000/00

    HN Size 0HN Size 1HN Size 1HN Size 2HN Size 3HN Size 3

    32326363100125160200250315400630800

    Suitable HRC fuse-link Open Execution In Sheet Steel Enclosure

    FN 32 TPN / FP CE*

    FN 63 TPN / FP CE*

    SK95612*

    SK95613*

    3590

    4295

    1

    1

    131517653750451549206255738093351124517895

    -

    M.R.P. (`)

    Per UnitSK95594SK95595ST35086ST35087ST35088ST35089ST31674ST38930ST31676ST35090

    -

    Cat. No.

    HFHF

    HN Size 000/00HN Size 000/00HN Size 000/00

    HN Size 0HN Size 1HN Size 1HN Size 2HN Size 3HN Size 3

    Suitable fuse-link typeType

    FN 32 2PFN 63 2PFN 100 2PFN 125 2PFN 160 2PFN 200 2PFN 250 2PFN 315 2PFN 400 2PFN 630 2PFN 800 TP

    RatedCurrent(A)

    3263100125160200250315400630800

    1595219544705575597073709560124151385523305

    -

    M.R.P. (`)

    Per Unit11111111111

    Std. Pkg(Nos.)

    SK95653SK95651SK95570SK95009SK95714SK95588SK95682SK95590SK95591SK95592

    -

    Cat. No.

    A1LA1LA4A4A4B2

    B2 / B3B3B4C2-

    Suitable fuse-link type

    Open Execution

    Type

    FN 32 TPNFN 63 TPN FN 100 TPNFN 125 TPNFN 160 TPNFN 200 TPNFN 250 TPNFN 315 TPNFN 400 TPNFN 630 TPN

    -

    Type FN (TP) S-D-F suitable for DIN fuse-link

    Type FN (2P) S-D-F suitable for DIN fuse-link

    Type FN (TPN) S-D-F suitable for bolted fuse-linkNew

    For Capacitor & Motor back-up

    FN TP S-D-F FN TPN S-D-F

    Type FN S-D-F suitable for DIN fuse-link Type FN S-D-F suitable for BS fuse-link

    Note: Please refer page no. 25 for Switch-Disconnector & 4 pole Switch-Disconnector-Fuse

    Open ExecutionOpen Execution

    L&T, ESP 01.11.2013

  • 28530530535037037037038540550550550551551553555555561575076079080581511801180125013201550

    SF94940SF94941SF94942SF94946SF94027SF94028SF94029SF94030SF94939SF94128SF94129SF94130SF94131SF94132SF94230SF94231SF94232SF94233SF94234SF94332SF94333SF94334SF94335SF94434SF94435SF94436SF94437SF94938

    Cat. No.M.R.P.

    (`) Per Unit

    Std.Pkg.(Nos.)

    Description

    3333333333333333333333311111

    RatedCurrent(A) 6380

    1001256380

    10012516080

    100125160200125160200250315200250315400315400500630800

    Size

    000

    00

    0

    1

    2

    3

    Suitable for T ype FN 200 / FNX 200 S-D-F& for HB 250 Fuse base

    Suitable for TypeFN 250/315 / FNX 250/315 S-D-F& for HB 250 Fuse base

    Suitable for Type FN 400 / FNX 400 S-D-F& for HB 800 Fuse base

    Suitable for Type FN 630/800 / FNX 630/800 S-D-F& for HB 800 Fuse base

    Suitable for TypeFN 100/125/160 / FNX 100/125/160 S-D-FSuitable for Type FA-C 100& for HB 160 Fuse base

    Suitable for TypeFN 100/125/160 / FNX 125/160 S-D-FSuitable for Type FA-C 100& for HB 160 Fuse base

    Cylindrical fuse links Type HF

    87878787878787878798215275

    SF90144SF90145SF90146SF90147SF90148SF90150SF90151SF90152SF90142SF90143SF90158SF90159

    Cat. No.M.R.P.

    (`) Per Unit

    Std.Pkg.(Nos.)303030303030303030303030

    RatedCurrent(A) 2468

    1016202532405063

    Description

    Suitable for Type FN 32 / 63 / FNX 32 / 63 S-D-F& for HCO 32 Fuse base

    Suitable for Type FN 63 / FNX 63 S-D-F& for HC 63 Fuse base

    Fuse & Fuse suitable for Cylindrical / DIN fuse-links holders bases

    DIN Type Fuse Links Type HN

    Features offered by HRC fuse link l Conforms to IEC 60269-2, IS 13703 part 2 l Range: 2A to 800A, 415V, AC 50Hzl Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)l High breaking capacity: 100kA for type HN and 80kA for type HF/HG/HQ

    HRC Fuses

    000

    00

    0

    1

    2

    3

    HCOHB

    1631852906001190

    M.R.P.(`)

    Per UnitSK91314SK91043SK90405SK90406SK91051

    Cat. No.Std.Pkg.(Nos.)10101233

    2-322-63

    63-16080-250200-800

    HFHF

    HN-Size 000 & 00HN-Size 0 & 1HN-Size 2 & 3

    RatedCurrent(A)

    Type TypeHCO 32HC 63HB 160HB 250HB 800

    3263

    160250800

    Range (A)

    HF 63A

    HF 2A

    Size

    14 X 51

    Description

    Fuse holderFuse holderFuse baseFuse baseFuse base

    Suitable fuse-link

    23L&T, ESP 01.11.2013

  • B1

    C2

    F1

    A1

    A1 L

    A2

    A3

    B2

    B3

    B4

    424242424247474759595959596162697272787878626262626262628989891691742102151901902452652752754004106156501115130913751520

    Offset,staggeredHG

    Offset

    Centre Tag,4 holes

    Size

    HQ

    Rating(A) Cat. No.

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Type FixingMethod

    Centre Tag,2 holes

    ST30725ST30726ST30727ST30728ST30729ST30730ST30731ST30732ST30736ST30737ST30738ST30739ST30740ST30741ST30742ST30743ST34527ST34528ST34529ST35827ST35828ST30747ST30748ST30749ST30750ST30751ST30752ST30753ST30759ST30760ST30761ST30767ST30768ST30769ST35829ST30774ST30775ST30776ST30777ST30778ST30779ST30781ST30782ST30783ST30784ST30785ST30786ST30787ST30788

    242424242424242424242424242424241515151515121212121212121212121212121212121233333331111

    246

    1016202532246

    1016202532202532506346

    101620253235506380

    10012516080

    100125125160200250315355400400500630630

    F1

    A1

    A1L

    A2

    A3

    A4

    B1

    B2

    B3

    B4

    C2

    C3

    Description

    Suitable for type HD 20H/20P/20B,

    HD 32H/32P/32B fuse base

    Suitable for type FN 32/63 S-D-F

    Suitable for type HK 32H/32B fuse base

    Suitable for type HK 63B/63H Fuse base

    Suitable for type FN 100/125/160 S-D-F

    & for HK 125H/125B Fuse base

    Suitable for type FN 200 S-D-F

    Suitable for type FN 250/315 S-D-F

    Suitable for type FN 400 S-D-F

    Suitable for type FN 630 S-D-F

    Fuse holders suitable for bolted fuse-links

    105116110116147137179210240290745815

    M.R.P.(`)

    Per UnitHD 20HHD 20PHD 20BHD 32HHD 32PHD 32BHK 32HHK 32BHK 63HHK 63BHK 125HHK 125B

    Connection Method FuseTypeRatedCurrent (A)

    SuitableFuse

    Range (A)Cat. No.

    Std.Pkg.(Nos.)

    ST30772ST30773ST30766ST30733ST30734ST30735ST30754ST30755ST30762ST30763ST30770ST30771

    2-202-202-202-322-322-324-324-3235-6335-6380-12580-125

    F1F1F1F1F1F1A2A2A3A3A4A4

    20

    32

    63

    125

    Type

    12121212121212126633

    Bolted fuse links: Type HG and HQ

    HD 32H HK 32H HK 63H HK 125H

    HRC Fuses

    24

    Both side cable (Front)Both side busbar (Back)Top busbar & bottom cableBoth side cable (Front)Both side busbar (Back)Top busbar & bottom cableBoth side cable (Front)Top busbar & bottom cableBoth side cable (Front)Top busbar & bottom cableBoth side cable (Front)Top busbar & bottom cable

    L&T, ESP 01.11.2013

  • Switch-Disconnector-Fuse Units

    Spares & Accessories for Type FFO/FF/FAC

    7080400

    M.R.P.(`)

    Per Unit63 / 10032 / 6332 / 63

    SK90453SK90998SK91079

    111

    DescriptionRatedCurrent(A)

    Cat. No.Std.Pkg.(Nos.)

    FAC - Handle AssemblyFFO / FF Handle AssemblyFFO / FF Handle Coupler &Door Interlock

    Type FFO/FF/FAC suitable for panel mounting

    1175178033005400

    M.R.P.(`)

    Per UnitDescription

    RatedCurrent(A)

    Cat. No.Std. Pkg.(Nos.)

    FFO TP InteriorFF TP InteriorFAC 63 TPNFAC 100 TPN

    326363

    100

    SK91100SK91000SK95156SK95157

    1111

    Type FN & FG Switch-Disconnector (TPN)

    FN TPN S-D

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    Cat. No.TypeRatedCurrent(A)

    1645224043055365731593201098013555201502333530590337404917062350166570197630201305

    11111111111111111

    SK95541SK95540SK95571SK95405SK95607SK95683SK95609SK95610SK95611SK95551SK95710SK95992ST30198ST30199ST30200ST30201ST30202

    FN 32 TPN / 4P FN 63 TPN / 4PFN 100 TPNFN 125 TPNFN 200 TPNFN 250 TPNFN 315 TPNFN 400 TPNFN 630 TPNFN 800 TPNFN 1000 TPNFN 1000H TPNFG 1250 TPNFG 1600 TPNFG 2000 TPNFG 2500 TPNFG 3150 TPN

    3263

    100125200250315400630800

    1000100012501600200025003150

    Refer catalogue for short circuit withstand capacity

    25

    1685231045656285684587051044013085155602515027260

    1685231045656385721593151080513530161402575528020

    M.R.P.(`)

    Per UnitM.R.P.(`)

    Per Unit11111111111

    11111111111

    Std.Pkg.(Nos.)

    Std.Pkg.(Nos.)

    SK96903SK96904SK96906SK95814SK95815SK95816SK95817SK95818SK95819SK95820SK95821

    Cat. No.Cat. No. TypeTypeType

    FNX 32 TPN / FPFNX 63 TPN / FPFNX 100 TPN / FP

    FNX 125 FPFNX 160 FPFNX 200 FPFNX 250 FPFNX 315 FPFNX 400 FPFNX 630 FPFNX 800 FP

    SK96903SK96904SK96906SK95806SK95807SK95808SK95809SK95810SK95811SK95812SK95813

    FNX 32 TPN / FPFNX 63 TPN / FPFNX 100 TPN / FPFNX 125 TPNFNX 160 TPNFNX 200 TPNFNX 250 TPNFNX 315 TPNFNX 400 TPNFNX 630 TPNFNX 800 TPN

    2 to 322 to 63

    63 to 10063 to 12563 to 16080 to 200125 to 250125 to 315200 to 400315 to 630315 to 800

    Range(A)

    HFHF

    HN Size 000HN Size 000/00HN Size 000/00

    HN Size 0HN Size 1HN Size 1HN Size 2HN Size 3HN Size 3

    Rated Current(A)

    3263100125160200250315400630800

    Suitable HRC fuse-link Three pole + Neutral (TPN) Four Pole (FP)

    Features offered by FNX S-D-FRange 32A to 800A, 415V, AC 23ATPN and FP versionSuitable for cylindrical / DIN fuse-linkTelescopic shaft for depth adjustment DIN rail mounting up to 100AConforms to IEC 60947-3, IS/IEC 60947-3 Door interlock & padlock facility

    lllllll

    Type FNX S-D-F suitable for DIN fuse-link in open execution

    FNX TPN S-D-F FNX 4P S-D-F

    L&T, ESP 01.11.2013

  • Switch-Disconnector-Fuse: Accessories Accessories for type FN

    Auxiliary Contact KitTerminal Shroud Kit

    Switched Neutral Kit Shaft Extension Kit

    Handle Assembly

    Accessories for type FNX

    Spare front housing assemblies for FN S-D-F (suitable for DIN fuse-link)

    28903380386552506325797514310

    M.R.P.(`)

    Per UnitStd.Pkg.(Nos.)

    1111111

    Cat. No.

    ST31677ST31678ST31679ST31729ST31681ST31682ST31683

    FN 100 Front housing assembly FN 125 Front housing assemblyFN 200 Front housing assembly FN 250 Front housing assembly FN 315 Front housing assembly FN 400 Front housing assembly FN 630 Front housing assembly

    DescriptionRating(A)100125200250315400630

    111111111111

    Std.Pkg.(Nos.)

    Cat. No.Description

    FNX 32 / 63FNX 100 FNX 125 / 160FNX 200 / 250FNX 315 / 400 / 630 / 800FNX 32 / 63 / 100FNX 125 / 160 / 200 / 250FNX 315 / 400 / 630 / 800FNX 32 / 63 / 100 FNX 125 / 160 / 200 / 250FNX 315 / 400 / 630 / 800FNX 32 / 63 / 100

    Auxiliary Contact Kit(1NO + 1 NC)

    Handle Assembly

    Castell Lock

    DIN Rail Assembly

    Type

    SK91537SK91538SK91539SK91540SK91541SK91524SK91525SK91526SK91530SK91531SK91531SK91617

    16031031040044527051064050088088065

    M.R.P.(`)

    Per Unit370420495545901202052152252605705706352605705706351452415245025453430190200210150180

    M.R.P.(`)

    Per Unit111111111111111111111111111

    Std.Pkg.(Nos.)

    Cat. No.

    SK91302SK91328SK91329SK91330*SK91190SK91137SK91335SK91346SK91347*SK91257SK91258SK91258SK91259*SK91277SK91278SK91278SK91279*SK91337SK95233SK95516SK95517SK95546*SK91343SK91344SK91345*SK95600SK91331*

    Description

    FN 32 / 63FN 100 / 125 / 160FN 200 / 250FN 315 / 400 / 630 / 800FN 32 / 63FN 100 / 125 / 160FN 200 / 250FN 315 / 400 FN 630 / 800FN 32 / 63FN 100 / 125 / 160FN 200 / 250FN 315 / 400 / 630 / 800FN 32 / 63FN 100 / 125 / 160FN 200 / 250FN 315 / 400 / 630 / 800FN 32 / 63FN 100 / 125 / 160FN 200 / 250FN 315 / 400 FN 630 / 800FN 200FN 315 / 400 FN 630 / 800FN 100 / 125 / 160FN 315 / 400 / 630 / 800

    * Also suitable for switch-disconnector FN1000 & FN1000H

    Auxiliary Contact Kit(1NO + 1 NC)

    Terminal Shroud Kit

    Handle Assembly - A

    Handle Assembly - B

    Handle Assembly - CE

    Switched Neutral Kit

    Shaft Extension Kit

    Interphase Barrier Kit

    Type

    Fuse pulling handle

    Fuse pulling handle forHF Fuse-link from 2A-63AInsulated fuse pulling handle forType HN fuse-link from 63A-800A

    SK91185

    SF90126

    110

    410

    1

    1

    Description Cat. No.M.R.P.

    (`)Per Unit

    Std.Pkg.(Nos.)

    Auxiliary Contact Kit Handle Assembly

    Castell Lock DIN Rail Assembly

    For Type HN fuse-link For Type HF fuse-link

    26

    Castell lock for type FN

    M.R.P.(`)

    Per UnitSuitable

    forTypeFN 100to FN 250

    Description & Cat. No.

    A = SK00333 B = SK00334 C = SK00335 D = SK00336A = SK00345* B = SK00346*

    C = SK00347* D = SK00348*

    Std.Pkg.(Nos.)

    1500

    1500

    2

    2

    Castell lock

    TypeFN 315to FN 800

    *Also suitable for Switch-Disconnector FN 1000 & FN 1000H

    L&T, ESP 01.11.2013

  • On Load Changeover Switch - DisconnectorsType changeover switch-disconnector Features offered by Changeover

    Range 63A to 1000A, 415V, AC 23A, 4PIEC 60947-3, IS/IEC 60947-3

    l

    l Conforms to l Staggered terminalsl Site convertible fuse version for open executionl Flip-able handle above 400A l Interchangeable dual shaft position with site convertibility l SS enclosure version does not require separate cable gland box

    Type

    CO1-63CO1-63CO1-100CO1-100CO2-125CO2-160CO2-200CO3-250CO3-315CO4-400CO4-630CO5-630CO5-800CO5-1000

    RatedCurrent(A)

    63631001001251602002503154006306308001000

    Cat. No.

    CO10630OOOOCO10630OOOD*CO11000OOOOCO11000OOOD*CO21250OOOOCO21600OOOOCO22000OOOOCO32500OOOOCO33150OOOOCO44000OOOOCO46300OOOOCO56300OOOOCO58000OOOOCO51000OOOO

    4295395054705070816090101087015365162652399028670300004251568620

    M.R.P.(`)

    Per UnitType

    CO2-125CO2-160CO2-200CO3-250CO3-315CO4-400CO4-630CO5-800CO5-1000

    Cat. No.

    CO21250OSOOCO21600OSOOCO22000OSOOCO32500OSOOCO33150OSOOCO44000OSOOCO46300OSOOCO58000OSOOCO51000OSOO

    Std. Pkg.(Nos.)

    111111111

    109451203013535192452016029565341255149087050

    M.R.P.(`)

    Per Unit

    Open Execution #In Sheet Steel EnclosureStd. Pkg.(Nos.)

    11111111111111

    Operating HandleSpares & Accessories for type / FG / FGC Auxiliary contact

    M.R.P.(`)

    Per UnitCat. No.

    Std.Pkg.(Nos.)

    CX10001OOOOCX30001OOOOCX40001OOOOCX50001OOOOST26591OOOOST26591OOOC

    4508001050114527502750

    Operating handle suitable for

    C/O Frame 1 (63-100A)C/O Frame 2 & 3 (125-315A)C/O Frame 4 (400-630A)C/O Frame 5 (800-1000A)FG Isolator 1000 / 1250 / 1600AFGC C/O 1000 / 1250A

    111111

    as open execution in SS enclosure

    Type in fuse version Fuse mountable kit (suitable for DIN fuse-link)

    Cat. No.Std. Pkg.(Nos.)

    63125160200250315400630800

    111111111

    M.R.P.(`)

    Per UnitCX10630OOCOCX21250OODOCX21600OODOCX22000OODOCX32500OODOCX33150OODOCX44000OODOCX56300OODOCX58000OODO

    11002820373547655115536078201689018870

    Fuse Mountable Kit

    CO Frame 1 63ACO Frame 2 125ACO Frame 2 160ACO Frame 2 200ACO Frame 3 250ACO Frame 3 315ACO Frame 4 400ACO Frame 5 630ACO Frame 5 800A

    RatedCurrent(A)

    HFSize 000Size 00Size 00Size 1Size 1Size 2Size 3Size 3

    Suitable fuse-link type

    DINType Cat. No.

    Std. Pkg.(Nos.)

    FGC 1250

    FG 1600

    RatedCurrent(A)1250

    1600

    ST27460OOOC

    ST27470OOOO

    1

    1

    102235

    141080

    M.R.P.(`)

    Per UnitBack to Back mtg. with 4 O/P terminalsBack to Back mtg. with 8 O/P terminals

    Description

    Type FG / FGC (TPN) changeover switch-disconnector

    FGC Changeover Fuse Mountable Kit

    Auxiliary Contact Operating Handle (63A to 315A) Flip-able Handle (400A to 1000A)

    28

    Direct handle F1 Extended handle F1

    CO1-63

    CO1-100

    CO10630OSOO

    CO11000OSOO

    6150

    7435

    1

    1

    * Direct handle version# All sheet steel enclosure version are with extended handle switch

    M.R.P.(`)

    Per UnitAuxiliary Contact Cat. No.

    Std.Pkg.(Nos.)

    400605660695795782

    111111

    2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC2 NO + 2 NC1 NO + 1 NC

    CX10002OOOOCX20002OOOOCX30002OOOOCX40002OOOOCX50002OOOOST26542OOOO

    C/O Frame 1 (63-100A)C/O Frame 2 (125-200A)C/O Frame 3 (250-315A)C/O Frame 4 (400-630A)C/O Frame 5 (800-1000A)FG & FGC (250 - 1600A)

    Auxiliary contact block suitable for

    New

    L&T, ESP 01.11.2013

  • MCCB Range

    lllll

    Conforms to IS/IEC 60947-2 & IEC 60947-2Comprehensive range from 0.63A to 1250A1, 2, 3 & 4 pole versionsBreaking capacities upto 70kAManual & Electrical operation

    l

    ll Solution for ASTS (

    Protection units: - Thermal Magnetic- Microprocessor based- Microprocessor based with communication & meteringComprehensive range of internal & external accessories

    Automatic Source Transfer System)

    Special Applicationsl For DC application, 2P MCCBs are availablel For Capacitor back up protection, MCCBs are availablel For Motor backup protection, use M series of MCCBs such as DM, DN0-M, DN2-M, DN3-M

    l For isolation, use SD version (without protection release)

    l Use of phase barriers is mandatory. These are supplied along with MCCBs

    l It is recommended to use spreader terminals for enhancing termination capacity

    l Spreader terminals are available as accessories, unless otherwise specified against Cat. Nos.

    l Spreaders are made of silver plated copper

  • DU100 MCCB

    DU250 MCCB

    Range: 16A to 100A, 2P & 3PCompact sizeAlso available in SS Enclosure Suitable for mounting on D-Pan assembly

    ll l l l

    Conforms to IS/IEC 60947-2 & IEC 60947-2

    Conforms to IS/IEC 60947-2 & IEC 60947-2Range: 100A to 250A, 3P & 4P

    ll l Compact sizel Wide Range of snap fit Internal and External Accessories l Adjustable Overload Setting: 0.8 - 1.0 x In

    p- Spreader Terminals are included - For 3P MCCBs*

    2P in 3P frame sizeNote:

    DU100

    Breaking Capacity

    Icu at 415V AC50Hz. (kA)

    Type

    1620253240506380100

    10

    M.R.P. (`)Per UnitCat. No. Cat. No.3 Pole

    CM97751OOOOCM97752OOOOCM97753OOOOCM97754OOOOCM97755OOOOCM97756OOOOCM97757OOOOCM98921OOOOCM98922OOOO

    CM97795OOOOCM97796OOOOCM97797OOOOCM97798OOOOCM97799OOOOCM97800OOOOCM97801OOOOCM97802OOOOCM97803OOOO

    1115*115*15*

    160016001600160016001600160017501750

    Std. Pkg.(Nos.)

    pp

    Current Rating(A)

    DU100H MCCB & IEC 60947-2

    Range: 20A to 100A, 2P, 3P & 4PCompact sizeAlso available in SS Enclosure

    lll

    Conforms to IS/IEC 60947-2

    l

    l l Wide Range of snap fit Internal and

    External Accessories l Adjustable Overload Setting: 0.8 - 1.0 x In

    Suitable for mounting on D-Pan assembly

    DU MCCB Range

    Thermal Release Range (A)

    Breaking Capacity Icu at 415V AC50Hz. (kA)

    16-2020-2525-3232-4040-5050-6363-8080-100

    Type

    DU100H 30

    M.R.P. (`)

    Per UnitM.R.P. (`)

    Per UnitCat. No.

    Std. Pkg.(Nos.)

    3 PoleCat. No.

    4 Pole

    55505550555055505550555055505550

    CM97933OOC2CM97933OOD2CM97933OOE2CM97933OOF2CM97933OOG2CM97933OOH2CM97933OOJ2CM97933OOK2

    11111111

    CM97894OOC2CM97894OOD2CM97894OOE2CM97894OOF2CM97894OOG2CM97894OOH2CM97894OOJ2CM97894OOK2

    41104110411041104110411041104110

    30

    16 Rating (A)Icu (kA)

    103036

    DU100DU100H

    DU250

    3 Pole 4 PoleBreaking Capacity Icu at 415V AC50Hz. (kA)

    Thermal Release Range (A)

    Std. Pkg.(Nos.)

    Type M.R.P. (`)Per Unit

    M.R.P. (`)

    Per UnitCat. No. Cat. No.

    7010765093901310015300

    CM98065OOKOCM98065OOLOCM98065OOMOCM98065OONOCM98065OOPO

    11111

    80-100100-125125-160160-200200-250

    CM98064OOOOCM98063OOOOCM98062OOOOCM98061OOOOCM98060OOOO

    5210581076501010011780

    36DU250

    20 25 32 40 50 63 80 100 125 160 200 250

    Note: 2P in 3P frame size For higher rating 2P MCCBs, please contact nearest branch

    M.R.P. (`)

    Per UnitCat. No.

    2 Pole

    CM97898OOC2CM97898OOD2CM97898OOE2CM97898OOF2CM97898OOG2CM97898OOH2CM97898OOJ2CM97898OOK2

    28002800280028002800280028002800

    New

    L&T, ESP 01.11.2013

    2 PoleM.R.P. (`)Per Unit111511151115111511151115111512251225

    pp

    New

  • Accessories for DU100Accessories for DU MCCBs

    Accessories for DU100H/DU250

    D-Pan Assembly

    M.R.P.(`)

    Per Unit

    D-Pan I/C 250A O/G 4 WayD-Pan I/C 250A O/G 8 WayD-Pan I/C 250A O/G 12 WayD-Pan I/C 400A O/G 4 WayD-Pan I/C 400A O/G 8 WayD-Pan I/C 400A O/G 12 Way

    DescriptionI/C - Cat. No.

    CM97821OOOOCM97822OOOOCM97823OOOOCM98605OOOOCM98606OOOOCM98607OOOO

    M.R.P.(`)

    Per Unit91051275016485106601430018030

    91051275016485106601430018030

    Cat. No.

    CM97912OOOOCM97913OOOOCM97914OOOOCM97915OOOOCM97916OOOOCM97917OOOO

    111111

    Std.Pkg.(Nos.)

    O/G - DU100 O/G - DN0 / DU100H

    Auxiliary Contact ATAC Shunt Release UV Release Direct Rotary Handle Extended Rotary Handle Spreader Terminals

    M.R.P. (`)

    Per Unit

    Description Cat. No.Std. Pkg.(Nos.)

    Internal

    6951180

    6951180

    1180

    990

    1330

    Auxiliary Contact 1 C/O - Right 2 C/O - RightTrip Alarm Contact 1 C/O - Right2 C/O - RightAuxiliary 1 C/O + TAC 1 C/ORightShunt Release 240/415V AC - Left Under Voltage Release 240V AC - Left

    CM97886OOOOCM97887OOOO

    CM97888OOOOCM97889OOOO

    CM97890OOOO

    CM97883OMOO

    CM97892BOOO

    11

    11

    1

    1

    1

    M.R.P. (`)

    Per Unit

    Description Cat. No. Std.Pkg.(Nos.)

    External

    19526510351260

    950101514101450

    Spreader Terminals DU100H - 3 PoleDU100H - 4 PoleDU250 - 3 PoleDU250 - 4 PoleRotary Handle DU100H - DirectDU250 - Direct DU100H - Extended DU250 - Extended

    CM97785OOOOCM97921OOOOST98053OOOOCM92007OOOO

    CM97895OOOOCM98040OOOOCM97896OOOOCM98041OOOO

    Set of 6Set of 8Set of 6Set of 8

    1111

    Offers a convenient solution for distribution l l Available for 250A, 400A main incomer 3P MCCBsl Available for 4, 8 & 12 ways 3P outgoing MCCBsl Type tested ( )

    M.R.P.(`)

    Per Unit

    405405

    500

    Auxiliary Contact 1 C/O - Right 1 C/O - LeftShunt Release 240/415V AC - Left

    Description Cat. No.

    CM97781OOOOCM97782OOOO

    CM97783OOOO

    11

    1

    Std.Pkg.(Nos.)

    InternalM.R.P.

    (`) Per Unit

    195

    750

    Spreader Terminals 3 PoleRotary HandleDirect

    Description Cat. No.

    CM97785OOOO

    SL97044OOOO

    Set of 6

    1

    Std.Pkg.(Nos.)

    External

    31

    Shunt Release Direct Rotary HandleSpreader Terminals Auxiliary Contact

    Note: MCCBs and shroud are shown for representation purpose only, need to be purchased separately.

    Note: Phase Barriers are supplied along with MCCBs

    Note: Phase Barriers are supplied along with MCCBs

    L&T, ESP 01.11.2013

  • l Conforms to IS/IEC 60947-2 & IEC 60947-2 l Range: 16A to 630A, 3P & 4Pl Ics = 100% Icu@l Adjustable thermal setting: 0.8-1.0 x Inl Also available in SS Enclosure for DH100/125/160/200l Wide Range of Internal and External Accessories

    32

    DH MCCB Range

    L&T, ESP 01.11.2013

    DU (DU125/160/200) MCCB Rangel & IEC 60947-2l Range: 125A to 200A, 3P & 4Pl Adjustable thermal setting: 0.8-1.0 x Inl Also available in SS Enclosurel

    Conforms to IS/IEC 60947-2

    Wide range of Internal and External Accessories

    p- Spreader Terminals are included # - Available till stocks last

    BreakingCapacity Icuat 415V. AC, 50Hz. (kA)

    ThermalRelease Range(A)

    M.R.P.(`)

    Per UnitCat. No.

    4 Pole

    CM97791OOOOCM97792OOOOCM97793OOOO

    CM98110OOOOCM98111OOOO

    -

    6850879011500

    875010640

    -

    M.R.P.(`)

    Per UnitCat. No.

    3 PoleType

    Std. Pkg.(Nos.)

    111

    DU125 #DU160 #DU200 #

    100-125128-160160-200

    30p pp pp

    DH MCCB Range

    - Spreader Terminals are included@ - Refer Catalogue for DH160, DH200 # - Available till stocks last

    3 PoleBreakingCapacity Icuat 415V AC, 50Hz. (kA)

    ThermalRelease Range(A)

    M.R.P.(`)

    Per UnitCat. No.

    Type

    DH100

    DH125

    DH160 # DH200 # DH400 #

    DH630 #

    12-1616-2020-2525-3232-4040-5050-6363-8080-10012-1616-2020-2525-3232-4040-5050-6363-8080-100100-125128-160160-200250-320320-400400-500500-630

    SL97201OOOOSL97202OOOOSL97203OOOOSL97204OOOOSL97205OOOOSL97206OOOOSL97207OOOOSL97208OOOOSL97209OOOOSL98644OOOOSL98645OOOOSL98646OOOOSL98647OOOOSL98648OOOOSL98649OOOOSL98650OOOOSL98651OOOOSL98652OOOOSL98653OOOOSL98654OOOOSL98655OOOOSL97883OOOOSL97884OOOOSL94531OOOOSL94532OOOO

    472047204720472047204720472047204970620062006200620062006200620062006920706099501192020900209002423024230

    p

    pppppp

    p

    p

    4 PoleM.R.P.

    (`) Per Unit

    Cat. No.Std. Pkg.(Nos.)

    SL98597OOOOSL98598OOOOSL98599OOOOSL98600OOOOSL98601OOOOSL98602OOOOSL98603OOOOSL98604OOOOSL98605OOOOSL98611OOOOSL98612OOOOSL98613OOOOSL98614OOOOSL98615OOOOSL98616OOOOSL98617OOOOSL98618OOOOSL98619OOOOSL98607OOOOSL98608OOOO

    11111111111111111111

    640064006400640064006400640064006740706070607060706070607060706070607890812010760

    p

    ppp

    35

    25

    16 20 25 32 40 63 80 10050

    DH125/160/200DH100

    DL100DH400/630

    Icu (kA) 253550

    125 160 200 320 400 500 630Rating (A)

    Note: For 2P MCCB, please contact nearest branch

  • 33

    DM MCCB Range for Motor Back-up Protection

    pPlease contact nearest branch office for fuseless type 2 co-ordination selection chart

    - Spreader Terminals are includedNote:

    l Conforms to IS/IEC 60947-2 & IEC 60947-2 l Range: 0.63A to 400A, 65kAl Short Circuit Protection : 12 Inl Wide Range of Internal and External Accessories

    TypeBreaking

    Capacity Icuat 415V,50Hz (kA)

    M.R.P.(`)

    Per UnitCat. No.

    3 PoleStd. Pkg.(Nos.)

    3515351535153515351535153515351535153515351587908790879087908790879087908790

    SL97581OOOOSL97582OOOOSL97583OOOOSL97584OOOOSL97585OOOOSL97586OOOOSL97587OOOOSL97588OOOOSL97589OOOOSL97590OOOOSL97591OOOOSL97811OOOOSL97812OOOOSL97816OOOOSL97813OOOOSL97814OOOOSL97817OOOOSL97815OOOOSL97987OOOO

    0.631.01.62.54.05.06.37.510.012.016.016.025.030.035.050.060.070.080.0

    1111111111111111111

    DM16

    DM100

    CurrentRating(A)

    65

    TypeBreaking

    Capacity Icuat 415V,50Hz (kA)

    M.R.P.(`)

    Per UnitCat. No.

    3 PoleStd. Pkg.(Nos.)

    DM160

    DM250

    DM400

    SL97123OOOOSL97703OOOOSL97124OOOOSL97551OOOOSL97552OOOOSL97553OOOOSL97554OOOOSL97555OOOOSL97556OOOOSL97557OOOO

    100.0120.0160.0200.0230.0250.0275.0325.0350.0400.0

    1111111111

    CurrentRating(A)

    13875138751387517895178951789521100211002110021100

    ppppppp

    65

    MCCB

    Starter

    M Representative Application Image

    L&T, ESP 01.11.2013

    DL MCCB Range

    - Spreader Terminals are included

    l Conforms to IS/IEC 60947-2 & IEC 60947-2 l Range: 16A to 100A, 3P & 4Pl Ics = 100% Icu l Adjustable thermal setting: 0.8-1.0 x Inl l

    Wide Range of Internal and External Accessories For Icu=65 kA, please contact branch office

    3 PoleBreakingCapacity Icuat 415V AC, 50Hz. (kA)

    ThermalRelease Range(A)

    M.R.P.(`)

    Per UnitCat. No.

    Type

    DL100

    12-1616-2020-2525-3232-4040-5050-6363-8080-100

    50

    SL97801OOOOSL97802OOOOSL97803OOOOSL97804OOOOSL97805OOOOSL97806OOOOSL97807OOOOSL97808OOOOSL97809OOOO

    9200920092009200920092009200920010170p

    4 PoleM.R.P.

    (`) Per Unit

    Cat. No.Std. Pkg.(Nos.)

    SL98620OOOOSL98621OOOOSL98622OOOOSL98623OOOOSL98624OOOOSL98625OOOOSL98626OOOOSL98627OOOOSL98628OOOO

    111111111

    104601046010460104601046010460104601046011530p

  • 34

    Extended Rotary HandleSpreader Terminal

    Accessories for DH100/125/160/200, DU125/160/200, DL100, DM100 MCCBs

    M.R.P.(`)

    Per UnitDescription Cat. No.

    Std.Pkg.(Nos.)

    Internal

    Auxiliary Contact 1 C/O - Right1 C/O - LeftTrip Alarm Contact 1 C/O - RightShunt Release 240V AC - Left

    *24V DC - Left Under Voltage Release 240V AC - Left

    765765

    765

    955955

    1280

    11

    1

    11

    1

    SL97296OOOOSL97297OOOO

    SL97