INTEGRATED MANUAL / AUTOMATIC DIALYZER REPROCESSING MACHINE HEM-REP-lJ J 1 I L.. 1 HEM-REP-01 Dialyzer Reprocessing is the main device to sterilization, clean test and affusion reusable dialyzer in hemodialysis treatment. It uses pulsating current oscillation technique, positive rinse, reverse rinse, positive UF,reverse UF etc. to eliminate leftover in dialyzer in short time to resume the capacity of blood volume and improve usage time. LCDtouch screen -convenience for customer operating.

Transcript of L - 3.imimg.com3.imimg.com/data3/OW/AM/MY-1849095/diaclean... · HEMANT SURqiCAllNduSTRiES LTd....

Page 1: L - 3.imimg.com3.imimg.com/data3/OW/AM/MY-1849095/diaclean... · HEMANT SURqiCAllNduSTRiES LTd. 647, Girgaum Road, Avijah Building, Shop NO.6 & 7, Near Metro Cinema, Mumbai-400 002

INTEGRATED MANUAL / AUTOMATICDIALYZER REPROCESSING MACHINE

HEM-REP-lJ J

1IL..

1

HEM-REP-01 Dialyzer Reprocessing is the main device to sterilization, clean test and

affusion reusable dialyzer in hemodialysis treatment. It uses pulsating current oscillation

technique, positive rinse, reverse rinse, positive UF,reverse UF etc. to eliminate leftover in

dialyzer in short time to resume the capacity of blood volume and improve usage time.

LCDtouch screen -convenience for customer operating.

Page 2: L - 3.imimg.com3.imimg.com/data3/OW/AM/MY-1849095/diaclean... · HEMANT SURqiCAllNduSTRiES LTd. 647, Girgaum Road, Avijah Building, Shop NO.6 & 7, Near Metro Cinema, Mumbai-400 002

Salient Features:

Technical Parameter:

580mm X 480mm x 320mm

approx.35kg

220V ± 10%, 50Hz-60Hz, 2A

ROwater complied with AAM 1/ASA 10 request

(Endotoxin < 2Eu/ml\Bacteriallevel< 200CFu)

20-60 psi

~ 1.2 liters/minute

Imported & Marketed By:

HEMANT SURqiCAllNduSTRiES LTd.647, Girgaum Road, Avijah Building, Shop NO.6 & 7, Near Metro Cinema,Mumbai-400 002 .• Tel. : 2203 0935, 2203 0936 • Fax: 91-22-2207 7585

Website: www.hemantsurgical.com • E-mail: [email protected]

Uses pulsating current oscillation technique to make ~w.a.ter

pressure oscillation around hollow fibrous coat in dialyzer. It is

easier to eliminate leftover also saving time and water,

improving usage time.

Uses negative pressure technique to separate the airfrom liquid.

It is more safety in affusion and rinse.

The design of automatic correction function make sure the

veracity in volume test.

It can work with one set or both two sets dialyzer. It improves

the work efficiency and red uce water consu mption.

It can rinse, clean, test, affuse dialyzer automatically or lonely

Also can set work data by user.

Type, volume and UF parameter etc of dialyzer can be stored in

the machine .The operation is more simple and accurate.

Fault hint and alarm offault function.

LCDtouch screen technique.

Printing function is convenient for user to register the results.

Alarm of no disinfectant make sure the safety of affusion;Can use any eligible disinfectant.

Reprocessing time (for whole work procedure) :

a. Foronedialyzerworking procedure about 12 min.

b. For tw'o dialyzer working procedures about 21 min.

2.

1 .

3.

6.

4.

5.

7.

8.

9.

10.

11.

12.

Size

Weight

Voltage

Water Input request

Water Input pressure

Water Flow rate

Minimum consumption: 8 liters/dialyzer

Reprocessing Time 12 minutes/dialyzer

(please be aware that, we will not make any notice if the parameter is changed)