Kyman User Manual

download Kyman User Manual

of 120

Transcript of Kyman User Manual

  • 8/13/2019 Kyman User Manual

    1/120

    Users Manual

    Kyman

  • 8/13/2019 Kyman User Manual

    2/120

    Datalogic Mobile S.r.l.Via S. Vitalino, 13

    40012 - Lippo di Calderara di RenoBologna - Italy

    Kyman - User's Manual

    Software Version: 3.03

    Ed.: 07/2010

    2006-2010 Datalogic Mobile S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S.and international laws. Copying, or altering of this document is prohibited without express written consentfrom Datalogic Mobile S.r.l.

    Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, includingthe U.S.A. and the E.U.KYMAN is a trademark of Datalogic Mobile S.r.l.

    All other brand and product names mentioned herein are for identification purposes only and may betrademarks or registered trademarks of their respective owners.Datalogic reserves the right to make modifications and improvements without prior notification.

    Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental orconsequential damages resulting from the use of this material.

  • 8/13/2019 Kyman User Manual

    3/120

    CONTENTS

    REFERENCES .............................................................................................VConventions.................................................................................................. vReference Documentation ............................................................................ vServices and Support.................................................................................... vSAFETY REGULATIONS............................................................................VIGeneral Safety Rules....................................................................................viBluetooth Approval.....................................................................................viLaser Safety.................................................................................................viiRadio Compliance....................................................................................... xiiiFCC Compliance..........................................................................................xvSAR Compliance..........................................................................................xvIndustry Canada Compliance.......................................................................xvPatents........................................................................................................xvi WEEE Compliance .................................................................................... xviiGENERAL VIEW ...................................................................................... XIX

    1 INTRODUCTION .......................................................................................... 11.1 Kyman Description .................................................................................... 11.2 Available Models........................................................................................... 21.3 Package Contents......................................................................................... 21.3.1 Using the Belt Clip ........................................................................................ 41.4 Handle Mounting........................................................................................... 61.5 Installing the SIM/SD Card............................................................................ 71.5.1 Removing the SIM Card and SD-Card.......................................................... 91.6 Accessories................................................................................................. 101.7 Operating System ....................................................................................... 112 CONNECTIONS ......................................................................................... 122.1 RS232/USB Direct Connection ................................................................... 122.2 WLAN Connection ...................................................................................... 132.3 WPAN Connections .................................................................................... 152.4 WWAN Connections ................................................................................... 162.5 Cradle Connections .................................................................................... 172.6 Connection Cables...................................................................................... 182.7 Wireless and Radio Frequencies Warnings ................................................ 203 USE AND FUNCTIONING.......................................................................... 223.1 Startup ........................................................................................................ 223.2 Windows Mobile Welcome Wizard.............................................................. 243.3 Using the Stylus.......................................................................................... 253.4 Data Capture............................................................................................... 263.4.1 Laser Data Capture..................................................................................... 26

    ii i

  • 8/13/2019 Kyman User Manual

    4/120

    3.4.2 Imager Data Capture .................................................................................. 273.4.3 RFID Data Capture ..................................................................................... 283.5 Description of the Keys ............................................................................... 293.5.1 Alphanumeric Keyboard (53-key Model)..................................................... 293.5.2 Numeric Keyboard (36-key Model) ............................................................. 323.5.3 Resetting the Kyman............................................................................... 353.6 Status Indicators ......................................................................................... 383.6.1 LED Status.................................................................................................. 383.6.2 Taskbar....................................................................................................... 393.7 Data Capture Configuration ........................................................................ 413.7.1 Configure .................................................................................................... 413.7.2 Capture ....................................................................................................... 473.8 Control Panel .............................................................................................. 483.8.1 Buttons........................................................................................................ 493.8.2

    Registry....................................................................................................... 50

    3.8.3 Files Admin ................................................................................................. 513.8.4 Wireless Communications........................................................................... 533.8.5 Ethernet Settings ........................................................................................ 553.8.6 Stylus Calibration ........................................................................................ 583.8.7 Volume Settings.......................................................................................... 623.9 Windows Connections ................................................................................ 663.9.1 Microsoft ActiveSync ............................................................................. 663.9.2 Bluetooth Manager Device Setup............................................................. 683.9.3 FTP Server Setup ....................................................................................... 753.10 Backup Directory File Management ............................................................ 763.11 Firmware Update for Windows CE.............................................................. 774 MAINTENANCE ......................................................................................... 784.1 Charging the Battery Pack .......................................................................... 784.2 Replacing the Battery Pack......................................................................... 804.3 Cleaning the Mobile Computer.................................................................... 835 TECHNICAL FEATURES........................................................................... 845.1 Technical Data ............................................................................................ 845.2 Reading Diagrams ...................................................................................... 886 TEST CODES............................................................................................. 90

    GLOSSARY................................................................................................ 93INDEX......................................................................................................... 96

    iv

  • 8/13/2019 Kyman User Manual

    5/120

    REFERENCES

    CONVENTIONSThis manual uses the following conventions:

    User refers to anyone using a Kyman mobile computer.Mobile computer and "Kyman" refer to Kyman mobile computer.You refers to the System Administrator or Technical Support person using thismanual to install, configure, operate, maintain or troubleshoot a Kyman mobilecomputer.

    REFERENCE DOCUMENTATION

    For further information regarding Kyman refer to the SDK Help on-Line.

    SERVICES AND SUPPORT

    Datalogic provides several services as well as technical support through its website.Log on to www.mobile.datalogic.com and click on the links indicated for further

    information including:- PRODUCTS

    Search through the links to arrive at your product page where you can downloadspecific Manualsand Software & Utilities

    - SERVICES & SUPPORT

    - Datalogic Services Warranty Extensions and Maintenance Agreements

    - Authorised Repair Centres

    - CONTACT US

    E-mail form and listing of Datalogic Subsidiaries

    v

  • 8/13/2019 Kyman User Manual

    6/120

    SAFETY REGULATIONS

    NOTE

    Read this manual carefully before performing any type of connectionto the Kyman mobile computer.The user is responsible for any damages caused by incorrect use ofthe equipment or by inobservance of the indication supplied in thismanual.

    GENERAL SAFETY RULES

    Use only the components supplied by the manufacturer for the specificKyman being used.

    Do not attempt to disassemble the Kyman mobile computer, as it does notcontain parts that can be repaired by the user. Any tampering will invalidate thewarranty.

    When replacing the battery pack or at the end of the operative life of theKyman mobile computer, disposal must be performed in compliance with thelaws in force.

    Before using the device and the battery packs, read par. 4.2.

    Do not submerge the Kyman in liquid products.

    Avoid significant and rapid temperature variations, which can producecondensation inside the Kyman and reduce its performance.

    For further information, refer to this manual and to the Datalogic Mobile web site:www.mobile.datalogic.com.

    BLUETOOTHAPPROVAL

    This product is equipped with the following certified Bluetooth module:

    Product Name: Datalogic controller subsystem based on LBMALCS2 MURATAmodule for Windows CE and Windows Mobile for portable barcode readersapplication

    Bluetooth ID: B016407

    Product ID: DLBTLCS2

    vi

    http://www.mobile.datalogic.com/http://www.mobile.datalogic.com/
  • 8/13/2019 Kyman User Manual

    7/120

    LASER SAFETY

    The laser light is visible to the human eye and is emitted from the window indicated inthe figure.

    This information applies to both laser models and the Kyman Imager AimingSystem.

    Laser output window

    I D F E

    La luce laser visibileall'occhio umano eviene emessa dallafinestra indicata nellafigura.

    Die Laserstrahlung ist frdas menschliche Augesichtbar und wird amStrahlaustrittsfensterausgesendet (siehe Bild).

    Le rayon laser est visible l'oeil nu et il est mispar la fentre dsignesur l'illustration dans lafigure.

    La luz lser es visible alojo humano y es emitidapor la ventana indicadaen la figura.

    LUCE LASERNON FISSARE IL FASCIOAPPARECCHIO LASER DICLASSE 2MASSIMA POTENZA DIUSCITA: 1,4 mWLUNGHEZZA D'ONDAEMESSA: 630~680 nmCONFORME A EN 60825-1(2001)

    LASERSTRAHLUNGNICHT IN DER STRAHLBLINKENPRODUKT DERLASERKLASSE 2MAXIMALEAUSGANGLEISTUNG: 1,4mWWELLENLNGE: 630~680nm

    ENTSPR. EN 60825-1(2001)

    RAYON LASEREVITER DE REGARDERLE RAYONAPPAREIL LASER DECLASSE 2PUISSANCE DE SORTIE:1,4 mWLONGUER D'ONDE EMISE:630~680 nmCONFORME A EN 60825-1

    (2001)

    RAYO LSERNO MIRAR FIJO EL RAYOAPARATO LSER DECLASE 2MXIMA POTENCIA DESALIDA: 1,4 mWLONGITUD DE ONDAEMITIDA: 630~680 nmCONFORME A EN 60825-1(2001)

    vi i

  • 8/13/2019 Kyman User Manual

    8/120

    ENGLISH

    The following information is provided to comply with the rules imposed byinternational authorities and refers to the correct use of your mobile computer.

    STANDARD LASER SAFETY REGULATIONSThis product conforms to the applicable requirements of both CDRH 21 CFR 1040Subchapter J and EN 60825-1:2001 at the date of manufacture.For installation, use and maintenance, it is not necessary to open the device.

    CAUTION

    Do not attempt to open or otherwise service any components in theoptics cavity. Opening or servicing any part of the optics cavity byunauthorized personnel may violate laser safety regulations. Theoptics system is a factory only repair item.

    CAUTION

    Use of controls or adjustments or performance of procedures otherthan those specified herein may result in exposure to hazardousvisible laser light.

    The product utilizes a low-power laser diode. Although staring directly at the laserbeam momentarily causes no known biological damage, avoid staring at the beam asone would with any very strong light source, such as the sun. Avoid that the laserbeam hits the eye of an observer, even through reflective surfaces such as mirrors,

    etc.

    CAUTION

    Use of optical systems with the scanner will increase eye hazard.Optical instruments include binoculars, microscopes, eye glassesand magnifying glasses.

    ITALIANO

    Le seguenti informazioni vengono fornite dietro direttive delle autorit internazionali esi riferiscono alluso corretto del terminale.

    NORMATIVE STANDARD PER LA SICUREZZA LASERQuesto prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla datadi produzione: CDRH 21 CFR 1040 sezione J e EN 60825-1:2001.Non si rende mai necessario aprire lapparecchio per motivi di installazione, utilizzo omanutenzione.

    viii

  • 8/13/2019 Kyman User Manual

    9/120

    ATTENZIONE

    Non tentare di accedere allo scomparto contenete i componentiottici o di farne la manutenzione.

    Lapertura dello scomparto, o la manutenzione di qualsiasi parteottica da parte di personale non autorizzato, potrebbe violare lenorme della sicurezza. Il sistema ottico pu essere riparatosolamente alla fabbrica.

    ATTENZIONE

    L'utilizzo di procedure o regolazioni differenti da quelle descrittenella documentazione pu provocare un'esposizione pericolosaa luce laser visibile.

    Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danniriportati dallocchio umano in seguito ad una esposizione di breve durata, evitare difissare il raggio laser cos come si eviterebbe qualsiasi altra sorgente di luminositintensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di unosservatore, anche attraverso superfici riflettenti come gli specchi.

    ATTENZIONE

    Luso di strumenti ottici assieme allo scanner pu aumentare ilpericolo di danno agli occhi. Tali strumenti ottici includono

    cannocchiali, microscopi, occhiali e lenti di ingrandimento.

    DEUTSCH

    Die folgenden Informationen stimmen mit den Sicherheitshinweisen berein, die voninternationalen Behrden auferlegt wurden, und sie beziehen sich auf den korrektenGebrauch vom Terminal.

    NORM FR DIE LASERSICHERHEIT

    Dies Produkt entspricht am Tag der Herstellung den gltigen EN 60825-1:2001 undCDRH 21 CFR 1040 Subchapter J Normen fr die Lasersicherheit.Es ist nicht notwendig, das Gert wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu ffnen.

    ACHTUNG

    Unter keinen Umstnden darf versucht werden, die Komponentenim Optikhohlraum zu ffnen oder auf irgendwelche andere Weisezu warten. Das ffnen bzw. Warten der Komponenten imOptikhohlraum durch unbefugtes Personal verstt gegen dieLaser-Sicherheitsbestimmungen. Das Optiksystem darf nurwerkseitig repariert werden.

    ix

  • 8/13/2019 Kyman User Manual

    10/120

    ACHTUNG

    Jegliche nderungen am Gert sowie Vorgehensweisen, die nichtin dieser Betriebsanleitung beschrieben werden, knnen ein

    gefhrliches Laserlicht verursachen.

    Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschden vonkurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden fr lngere Zeit in denLaserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die Sonne).Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, nochgegen reflektierende Oberflchen zu richten.

    ACHTUNG

    Die Verwendung von Optiksystemen mit diesem Scanner erhht die

    Gefahr einer Augenbeschdigung. Zu optischen Instrumentengehren unter anderem Fernglser, Mikroskope, Brillen undVergrerungsglser.

    FRANAIS

    Les informations suivantes sont fournies selon les rgles fixes par les autoritsinternationales et se rfrent une correcte utilisation du terminal.

    NORMES DE SECURITE LASER

    Ce produit est conforme aux normes de scurit laser en vigueur sa date defabrication: CDRH 21 CFR 1040 sous-chapitre J et EN 60825-1:2001.Il nest pas ncessaire douvrir lappareil pour linstallation, lutilisation ou lentretien.

    ATTENTION

    Ne pas essayer douvrir ou de rparer les composants de lacavit optique. Louverture de la cavit optique ou la rparationde ses composants par une personne non qualifie peutentraner le non-respect des rgles de scurit relatives au laser.Le systme optique ne peut tre rpar quen usine.

    ATTENTION

    L'utilisation de procdures ou rglages diffrents de ceux donnsici peut entraner une dangereuse exposition lumire laservisible.

    Le produit utilise une diode laser. Aucun dommage aux yeux humains na tconstat la suite dune exposition au rayon laser. Eviter de regarder fixement lerayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi

    de diriger le rayon vers les yeux dun observateur, mme travers des surfacesrflchissantes (miroirs, par exemple).

    x

  • 8/13/2019 Kyman User Manual

    11/120

    ATTENTION

    Lutilisation dinstruments optiques avec le scanneur augmente ledanger pour les yeux. Les instruments optiques comprennent les

    jumelles, les microscopes, les lunettes et les verres grossissants.

    ESPAOL

    Las informaciones siguientes son presentadas en conformidad con las disposicionesde las autoridades internacionales y se refieren al uso correcto del terminal.

    NORMATIVAS ESTNDAR PARA LA SEGURIDAD LSEREste aparato resulta conforme a las normativas vigentes de seguridad lser a lafecha de produccin: CDRH 21 CFR 1040 Seccin J y EN 60825-1:2001.No es necesario abrir el aparato para la instalacin, la utilizacin o la manutencin.

    ATENCIN

    No intente abrir o de ninguna manera dar servicio a ninguno de loscomponentes del receptculo ptico. Abrir o dar servicio a laspiezas del receptculo ptico por parte del personal no autorizadopodra ser una violacin a los reglamentos de seguridad. Elsistema ptico se puede reparar en la fbrica solamente.

    ATENCIN

    La utilizacin de procedimientos o regulaciones diferentes deaquellas describidas en la documentcin puede causar unaexposicin peligrosa a la luz lser visible.

    El aparato utiliza un diodo lser a baja potencia. No son notorios daos a los ojoshumanos a consecuencia de una exposicin de corta duracin. Eviten de mirar fijo elrayo lser as como evitaran cualquiera otra fuente de luminosidad intensa, porejemplo el sol. Adems, eviten de dirigir el rayo lser hacia los ojos de unobservador, tambin a travs de superficies reflectantes como los espejos.

    ATENCIN

    El uso de sistemas pticos con el escner aumentar el riesgo dedaos oculares. Los instrumentos pticos incluyen binoculares,microscopios, lentes y lupas.

    xi

  • 8/13/2019 Kyman User Manual

    12/120

    LED Illuminator

    The use of an illuminator in the Kyman Imager models is a Class 1 LED product:

    CLASS 1 LED PRODUCTILLUMINATORE LED CLASSE 1

    AUSLEUCHTER LED KLASSE 1

    ILLUMINATEUR A LED DE CLASSE 1

    ILUMINADOR LED DE CLASE 1

    xii

  • 8/13/2019 Kyman User Manual

    13/120

    RADIO COMPLIANCE

    In radio systems configured with mobile computers and access points, thefrequencies to be used must be allowed by the spectrum authorities of the specific

    country in which the installation takes place. Be absolutely sure that the systemfrequencies are correctly set to be compliant with the spectrum requirements of thecountry.

    The Radio modules used in this product automatically adapt to the frequencies set bythe system and do not require any parameter settings.

    The following shows the correspondence between the Kyman models and theRadio modules:

    Kyman 7XX-XXX 802.11b/g (Wi-Fi) radio card

    Kyman X1X-XXX GSM/GPRS Tri-band (900,1800,1900 MHz) module

    Kyman X2X-XXX GSM/GPRS/EDGE Quad-band (800,900,1800,1900 MHz)module

    Information for the User

    ENGLISH

    Contact the competent authority responsible for the management of radio frequencydevices of your country to verify any possible restrictions or licenses required. Referto the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for furtherinformation.

    ITALIANO

    Contatta l'autorit competente per la gestione degli apparati a radio frequenza del tuopaese, per verificare eventuali restrizioni o licenze. Ulteriori informazioni sonodisponibili sul sito:http://europa.eu.int/comm/enterprise/rtte/spectr.htm.

    FRANAIS

    Contactez l'autorit comptente en la gestion des appareils radio frquence devotre pays pour vrifier d'ventuelles restrictions ou licences. Pour toutrenseignement vous pouvez vous adresser au site web:http://europa.eu.int/comm/enterprise/rtte/spectr.htm.

    xiii

    http://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htm
  • 8/13/2019 Kyman User Manual

    14/120

    DEUTSCH

    Wenden Sie sich an die fr Radiofrequenzgerte zustndige Behrde Ihres Landes,um zu prfen ob es Einschrnkungen gibt, oder eine Lizenz erforderlich ist. WeitereInformationen finden Sie auf der Web Seite:

    http://europa.eu.int/comm/enterprise/rtte/spectr.htm.

    ESPAOL

    Contacta la autoridad competente para la gestin de los dispositivos de radiofrecuencia de tu pas, para verificar cualesquiera restricciones o licencias posiblesrequerida. Adems se puede encontrar mas informacin en el sitio web:http://europa.eu.int/comm/enterprise/rtte/spectr.htm.

    xiv

    http://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htmhttp://europa.eu.int/comm/enterprise/rtte/spectr.htm
  • 8/13/2019 Kyman User Manual

    15/120

    FCC COMPLIANCE

    Modifications or changes to this equipment without the expressed written approval ofDatalogic could void the authority to use the equipment.

    This device has been tested and found to comply with the limits for a CLASS A digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference when the equipment is operatedin a commercial environment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with the instructionmanual, may cause harmful interference to radio communications. Operation of thisequipment in a residential area is likely to cause harmful interference in which casethe user will be required to correct the interference at his own expense.

    FCC ID: U4G0016 for models with only 802.11b/g radioFCC ID: U4G0050 for models with 802.11b/g radio and Bluetooth

    SAR COMPLIANCE

    This product has been tested and found to comply with the following standards:

    - EN50360: product standard to demonstrate the compliance of mobile phones with thebasic restrictions related to human exposure to electromagnetic fields (300 MHz 3 GHz).

    - EN50361: basic standard for the measurement of specific absorption rate related to

    human exposure to electromagnetic fields from mobile phones (300 MHz 3 GHz).- OET BULLETIN 65 SUPPLEMENT C: evaluating compliance with FCC guidelinesfor human exposure to radio frequency electromagnetic fields.

    - Australian Radiation Protection And Nuclear Safety Agency (ARPANSA): radiationprotection series publication No. 3: maximum exposure levels to radio frequencyfields 3 KHz TO 300 GHz.

    INDUSTRY CANADA COMPLIANCE

    Operation is subject to the following two conditions: (1) this device may not causeinterference, and (2) this device must accept any interference, including interferencethat may cause undesired operation of the device.

    The highest measured SAR level is 0.186 W/Kg.

    xv

  • 8/13/2019 Kyman User Manual

    16/120

    PATENTS

    This product is covered by one or more of the following patents.U.S. Patents Nos: 5,992,740; 6,512,218 B1; 6,808,114B1; 6,877,664B1;

    6,997,385B2;7,102,116 B2; 7,282,688 B2; 7,387,246 B2; 7,468,499 B2.European patents Nos: 681,257B1; 789,315B1; 999,514 B1; 1,128,315 B1;1,172,756 B1 1,396,811 B1; 1,413,971 B1.

    xvi

  • 8/13/2019 Kyman User Manual

    17/120

    WEEE COMPLIANCE

    Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC

    Lapparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine dellasua vita utile, separatamente dai rifiuti urbani.

    Smaltire lapparecchiatura in conformit alla presente Direttiva consente di: evitare possibili conseguenze negative per lambiente e per la salute umana che

    potrebbero invece essere causati dallerrato smaltimento dello stesso; recuperare materiali di cui composto al fine di ottenere un importante risparmio di

    energia e di risorse.

    Per maggiori dettagli sulle modalit di smaltimento, contattare il Fornitore dal quale stataacquistata lapparecchiatura o consultare la sezione dedicata sul sitowww.mobile.datalogic.com.

    Information for the user in accordance with the European Commission Directive2002/96/EC

    At the end of its useful life, the product marked with the crossed out wheeled wastebin must bedisposed of separately from urban waste.

    Disposing of the product according to this Directive: avoids potentially negative consequences to the environment and human health

    which otherwise could be caused by incorrect disposal enables the recovery of materials to obtain a significant savings of energy and

    resources.

    For more detailed information about disposal, contact the supplier that provided you with theproduct in question or consult the dedicated section at the website www.mobile.datalogic.com.

    Information aux util isateurs concernant la Directive Europenne 2002/96/EC

    Au terme de sa vie utile, le produit qui porte le symbole d'un caisson ordures barr ne doit pastre limin avec les dchets urbains.

    liminer ce produit selon cette Directive permet de:

    xvii

  • 8/13/2019 Kyman User Manual

    18/120

    viter les retombes ngatives pour l'environnement et la sant drivant d'unelimination incorrecte

    rcuprer les matriaux dans le but d'une conomie importante en termes d'nergieet de ressources

    Pour obtenir des informations complmentaires concernant l'limination, veuillez contacter lefournisseur auprs duquel vous avez achet le produit ou consulter la section consacre au siteWeb www.mobile.datalogic.com.

    Informacin para el usuario de accuerdo con la Directiva Europea 2002/96/CE

    Al final de su vida til, el producto marcado con un simbolo de contenedor de bassura mviltachado no debe eliminarse junto a los desechos urbanos.

    Eliminar este producto de accuerdo con la Directiva permite de: evitar posibles consecuencias negativas para el medio ambiente y la salud derivadasde una eliminacin inadecuada

    recuperar los materiales obteniendo as un ahorro importante de energa y recursos

    Para obtener una informacin ms detallada sobre la eliminacin, por favor, pngase encontacto con el proveedor donde lo compr o consultar la seccin dedicada en el Web sitewww.mobile.datalogic.com.

    Benutzerinformation bezglich Richtlinie 2002/96/EC der europischen Kommission

    Am Ende des Gertelebenszyklus darf das Produkt nicht ber den stdtischen Hausmllentsorgt werden. Eine entsprechende Mlltrennung ist erforderlich.

    Beseitigung des Produkts entsprechend der Richtlinie: verhindert negative Auswirkungen fr die Umwelt und die Gesundheit der Menschen ermglicht die Wiederverwendung der Materialien und spart somit Energie und

    Resourcen

    Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten ber den sie dasProdukt erworben haben, oder besuchen sie unsere Hompage unterwww.mobile.datalogic.com.

    xviii

  • 8/13/2019 Kyman User Manual

    19/120

    GENERAL VIEW

    B DC E

    I

    AJ

    K

    F

    G

    LH

    A) Backlit displayB) User programmable LEDC) SpeakerD) Good read LEDE) Charging status and battery low

    warning LEDF) Scan key

    G) KeyboardH) MicrophoneI) Laser safety labelJ) Product labelK) Adjustable elastic strap with stylus

    holdersL) Battery pack

    xix

  • 8/13/2019 Kyman User Manual

    20/120

    M

    N

    M) Trigger (Gun Version Only)N) Handle (Gun Version Only)

    P

    O

    O) Data capture/Laser Output window P) Communication/Charger/Headset

    connector

    xx

  • 8/13/2019 Kyman User Manual

    21/120

    INTRODUCTION1

    1 INTRODUCTION

    1.1 KYMAN DESCRIPTION

    The Datalogic Kyman rugged mobile computer is one of the key elements ofDatalogics mobile@work product family for logistic solutions.

    Kyman, thanks to the lightest weight of its category combined with one of the bestergonomics ever seen on the market, reduces the operators fatigue with nocompromises in terms of reliability and robustness. Its sturdy outer casing withovermold protection has been designed to resist harsh environments, multiple drops,

    strong shocks, repetitive tumbles as well as sub-zero temperatures.Available in both handheld and pistol-grip models, Kyman guarantees maximumflexibility thanks to the add-on handle. In fact, it is possible to insert or remove thehandle by simply using a screwdriver, maintaining, at the same time, its industrystandard performance for sealing and drop capabilities.

    Kyman key features include fully integrated automatic data capture (1D bar code,1D bar code & RFID HF-ISO tags, 1D & 2D bar codes & images), allowing codes tobe read from near contact to several meters distance and simultaneous wirelesscommunication capabilities (Bluetooth, Wi-Fi, GSM/GPRS/EDGE).

    Kyman system architecture is based on the de-facto standard combination of thefastest Intel X-Scale series processors coupled with the Windows CE 5.0 operatingsystem and it is ready to satisfy the most demanding customer needs (i.e. allowing toexpand its memory thanks to a Secure Digital standard slot).

    Kyman provides 2 intuitive keyboard layouts, numeric/alphanumeric with backlight,able to fulfill 100% traditional text based applications (i.e. terminal emulation, throughthe DL-TCL-NET software client) as well as the most modern Web-based solutions(i.e. exploiting the Microsoft Internet Explorer through the DL Locked Web Browserapplication).Kyman provides mobile professionals with the most relevant features needed tooperate in demanding environments: reliability, ruggedness, drop resistance, longlasting batteries, flexible communication and efficient data capture.

    1

  • 8/13/2019 Kyman User Manual

    22/120

  • 8/13/2019 Kyman User Manual

    23/120

    INTRODUCTION1

    Other accessories, necessary for the Kyman connection to the host computer andto the network are sold saparately: the cradle, power supply, and one or moreconnection cables.

    Remove all the components from their packaging; check their integrity and congruitywith the packing documents.

    CAUTION

    Keep the original packaging for use when sending products to thetechnical assistance center. Damage caused by improperpackaging is not covered under the warranty.

    NOTE

    Rechargeable battery packs are not initially charged. Therefore thefirst operation to perform is to charge them. See paragraph 4.1.

    3

  • 8/13/2019 Kyman User Manual

    24/120

    KYMAN1

    1.3.1 Using the Belt Clip

    To use the belt clip, proceed as follows:

    1. Remove the elastic strap and unscrew the strap pivot.

    2. Release the belt clip pivot by pressing the belt clip unlock button.

    3. Screw the belt clip pivot on the terminal by using the fixing screw.

    4

  • 8/13/2019 Kyman User Manual

    25/120

  • 8/13/2019 Kyman User Manual

    26/120

    KYMAN1

    1.4 HANDLE MOUNTING

    1- Unscrew the A, B and C screwswith a philips screwdriver andremove the cover of the handleconnector socket.

    2- Insert the handle connector intothe socket paying attention tothe insertion key.

    3- Fix the handle to the mobilecomputer body using the threescrews included in the handlepackage.

    A

    C

    B

    6

  • 8/13/2019 Kyman User Manual

    27/120

  • 8/13/2019 Kyman User Manual

    28/120

    KYMAN1

    4- Insert the SIM CARD with thecontacts downward and SDCARD with the contactsupward.

    5- Push the cards into the slotusing Datalogic Stylus until itclicks into place.

    CAUTION

    Follow proper ESD precautions to avoid damaging the SIM/SD. ProperESD precautions include, but are not limited to, working on an ESD matand ensuring that the operator is properly grounded.Do not force the card. If you feel resistance, remove the card, checkthe orientation, and reinsert it.Do not use the SIM/SD card slot for any other accessories.

    8

  • 8/13/2019 Kyman User Manual

    29/120

    INTRODUCTION1

    1.5.1 Removing the SIM Card and SD-Card

    To remove the SIM card and the SD-card, follow the steps above to access the SIMand SD-card area, and then follow the steps below:

    1- To remove the SIM card andthe SD card, just push themtoward the inside, aided by thetip of the stylus, until they click;a spring system will return themout.

    PCBNOTCH

    NOTE

    All the basic functionalities normally associated to the SIM card aremanaged by the terminal (GPRS connectivity, phone calls, SMShandling).It is possible that not all the services connected to the SIM card can be

    used or can be managed by the terminal.

    9

  • 8/13/2019 Kyman User Manual

    30/120

    KYMAN1

    1.6 ACCESSORIES

    Cradles

    94A151101 Kyman Single Cradle Desk (includes slot for spare battery pack recharge;

    RS232 and USB communications)94A151107 Kyman Vehicle Cradle

    94A151115 Kyman Ethernet Desk Multi Cradle

    Charger

    94A151102 Kyman Multi-Battery Pack Charger (4 slots)

    Batteries94ACC1302 Kyman Standard Battery Pack (Li-Ion battery pack 2200 [email protected] V)

    Power Supply

    94ACC4595 FPS18 Power Supply without cord for Kyman Single Cradle Desk, forKyman Multi-Battery Charger and for WIN-NET Serial/USB PWR Cables

    94ACC1337 FPS19 W/O Power Cord, for Kyman Ethernet Desk Multi Cradle

    94ACC1150 Power cord EU 3-pin

    Cables

    94A051008 WIN-NET SERIAL CABLE (HRS 3500-16P-CV) cable for RS232 directconnection between the mobile computer and the PC

    94A051009 WIN-NET USB CABLE (HRS 3500-16P-CV) cable for USB direct connectionbetween the mobile computer and the PC

    94A051014 WIN-NET SERIAL PWR CABLE (HRS 3500-16P-CV) cable for RS232 andpower connections

    94A051015 WIN-NET USB PWR CABLE (HRS 3500-16P-CV) cable for USB and powerconnections

    94A051012 WIN-NET VEHICLE PWR CAB (HRS 3500-16P-CV) cable for car/truckcigarette lighter power adapter

    Various

    94ACC1331 vo-CE HEADSET

    94ACC1332 vo-CE HEADSET ADAPTER FOR Kyman

    94ACC1304 Kyman Belt Holster

    94ACC1303 Kyman Functional Case

    94ACC1301 Stylus Pen (20 pcs)

    94ACC1343 Datalogic Kyman Backstrap Kit

    94ACC1336 Kyman Gun Handle

    10

  • 8/13/2019 Kyman User Manual

    31/120

    INTRODUCTION1

    NOTE

    Use only a Datalogic Mobile-approved power supply and cables. Useof an alternative power supply will invalidate any approval given tothis device and may be dangerous.

    1.7 OPERATING SYSTEM

    Datalogic Kyman comes in two different models, respectively supporting WindowsCE and Windows Mobile.For further information regarding Windows Mobile refer to the website:http://www.microsoft.com/windowsmobile.

    11

  • 8/13/2019 Kyman User Manual

    32/120

    KYMAN2

    2 CONNECTIONS

    2.1 RS232/USB DIRECT CONNECTIONYou can use a cable to connect the Kyman to a host computer to transfer data.

    Key:

    A Host computer C RS232 cable or USB cable

    B Kyman

    Key:

    A Host computer C RS232 cable or USB cable

    B Kyman D Power Supply*

    * Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).

    CAUTION

    If the PDA supports Windows Mobile, before plugging the RS232cable you have to check the 'COM1 Enable' option on the 'SystemConfiguration' window. (Start -> Programs -> SystemConfiguration).

    CAUTION

    USB communication may not be completely guaranteed whilebatteries are simultaneously in charge. Avoid the power supply

    connection when the USB link is active.

    12

  • 8/13/2019 Kyman User Manual

    33/120

    CONNECTIONS2

    2.2 WLAN CONNECTION

    Kyman Wi-Fi 802.11b and Wi-Fi 802.11b/g1models can communicate with the hostusing the on-board radio frequency module and an Access Point connected to the

    host computer.

    For models using the WiFi7 radio (7xx-xxx-xxx models), you can find informationabout the applet for radio configuration: http://www.summitdatacom.com/SCU.htm.To launch this utility you can tap the specific icon if its visible on the taskbar or:1. On Windows CE device, you can open Connections folder or Control Panel from

    desktop and select the Summit Client Utility icon.2. On Windows Mobile device, you can select the menu item: Start->Programs-

    >Summit and tap the Summit Client Utility icon.

    A

    B

    C

    Key:

    A) Kyman

    B) Access point

    C) Host Application Server

    1Note: unless otherwise specified, the Wi-Fi term is used both for the 802.11b and the 802.11b/g cards.

    13

    http://www.summitdatacom.com/SCU.htmhttp://www.summitdatacom.com/SCU.htm
  • 8/13/2019 Kyman User Manual

    34/120

    KYMAN2

    NOTE

    Wi-Fi module is on by default. In order to avoid wasting energy, youcan switch it off using the Wireless Communications applet (see par.3.8.4). To start configuring your WLAN connection, tap the Wi-Fi iconat the bottom of the screen.

    NOTE

    Suspending the terminal powers off the 802.11b/g radio and dropsthe radio connection. When the terminal resumes, depending on theradio power mode and security protocol selected, it takesapproximately from 10 to 30 seconds for the 802.11b/g radio driver tore-associate the radio to the network.

    NOTE

    Area coverage and radio performance may vary, due toenvironmental conditions, access points types or interference causedby other devices (microwave ovens, radio transmitters, etc.).

    14

  • 8/13/2019 Kyman User Manual

    35/120

    CONNECTIONS2

    2.3 WPAN CONNECTIONS

    Kyman mobile computers can communicate with a Bluetoothdevice, such as aprinter, within a range of 10 m, using the on-board Bluetoothmodule.

    BA

    Key:

    A) Kyman

    B) Bluetoothprinter

    NOTE

    In order to avoid wasting energy, the Bluetooth module is off bydefault. If you need to have Bluetooth working, the module must bepowered on using the Wireless Communications applet (see par.3.8.4), and perform the Discovery procedure (see par. 3.9.2).

    NOTE

    Suspending the terminal powers off the Bluetooth radio and dropsthe piconet (Bluetooth connection). When the terminal resumes, ittakes approximately 10 seconds for the Bluetooth radio driver to re-initialize the radio.

    NOTE

    Area coverage and Bluetooth radio performance may vary, due toenvironmental conditions or interference caused by other devices(microwave ovens, radio transmitters, etc.), etc.

    15

  • 8/13/2019 Kyman User Manual

    36/120

    KYMAN2

    2.4 WWAN CONNECTIONS

    Kyman GSM/GPRS/EDGE models enhance your connectivity solutions giving youan opening to an international wireless infrastructure that is the standard in Europe

    and Asia.

    GSM (Global System for Mobile communications), is a digital mobile phone systembased on TDMA; it utilizes the 800, 900, 1800 and 1900 MHz bands.

    GPRS supports IP (Internet Protocol) and allows accessing Internet and Intranetservices, such as sending and receiving e-mail or Web browsing.

    In order to use a WWAN Connection you have to install a SIM Card (see instructionson par. 1.5).

    NOTE

    In order to avoid wasting energy, the GSM/GPRS module is off bydefault. If you need to have GSM/GPRS working, the module must bepowered on using the Wireless Communications applet (see par. 3.8.4)

    16

  • 8/13/2019 Kyman User Manual

    37/120

    CONNECTIONS2

    NOTE

    Suspending the terminal powers off the GSM/GPRS radio and drops theconnection.When the terminal resumes, if the connection was managed by Microsoft

    Internet Explorer, it is automatically restored, otherwise, the radioconnection must be manually re-initialized.

    NOTE

    The GSM voice capability of this mobile computer has to be addressedto occasional use, in well covered areas.If the coverage is poor, the voice quality can be highly affected.In case of vehicle cradle installations, a good habit is to install theexternal microphone to minimize the risk of noises and echoes.If the coverage is poor, in case of continuous communication, some

    degradation of the barcode reading capabilities can be experienced.

    2.5 CRADLE CONNECTIONS

    The Kyman can also communicate via RS232, USB and Ethernet, using variouscradle models.For further details, refer to the specific cradle model Users Manual.

    17

  • 8/13/2019 Kyman User Manual

    38/120

  • 8/13/2019 Kyman User Manual

    39/120

    CONNECTIONS2

    RS232 Direct Connection:

    94A051014 WIN-NET SERIAL PWR CABLE (HRS 3500-16P-CV)

    RX

    TX3

    6 2

    5

    1

    CTS

    16-pin

    HOST/PC side

    9-pin (female)

    Mobile Computer side

    6

    8

    7

    8

    9

    10

    51

    2

    3

    4

    13

    TXRX

    RTS CD

    DSR DSR

    DTR CTS

    GND

    VALIM

    GND

    GND

    GNDPOWER

    CONNECTOR

    USB Direct Connection:

    94A051015 WIN-NET USB PWR CABLE (HRS 3500-16P-CV)

    HOUSING

    1

    D(+)2

    3

    D(-)16

    15

    14 V+

    SHIELDHOUSING

    4

    13

    3

    21

    4

    POWER

    GND

    VALIM

    Power Supply Polarity:

    GND

    VEXT

    19

  • 8/13/2019 Kyman User Manual

    40/120

    KYMAN2

    2.7 WIRELESS AND RADIO FREQUENCIES WARNINGS

    WARNING

    Use only the supplied or an approved replacement antenna.

    Unauthorized antennas, modifications or attachments coulddamage the product and may violate laws and regulations.

    WARNING

    Most modern electronic equipment is shielded from RF signals.However, certain electronic equipment may not be shielded againstthe RF signals generated by the Kyman.

    WARNING

    Datalogic recommends persons with pacemakers or other medicaldevices to follow the same recommendations provided by HealthIndustry Manufacturers Associations for mobile phones.Persons with pacemakers: Should ALWAYS keep this device more than twenty five (25) cm

    from their pacemaker and/or any other medical device; Should not carry this device in a breast pocket; Should keep the device at the opposite side of the pacemaker

    and/or any other medical device; Should turn this device OFF or move it immediately AWAY if there

    is any reason to suspect that interference is taking place. Should ALWAYS read pacemaker or any other medical device

    guides or should consult the manufacturer of the medical device todetermine if it is adequately shielded from external RF energy.

    In case of doubt concerning the use of wireless devices with animplanted medical device, contact your doctor.

    WARNING

    Turn this device OFF in health care facilities when any regulationsposted in these areas instruct you to do so. Hospitals or health carefacilities may use equipment that could be sensitive to external RFenergy.

    20

  • 8/13/2019 Kyman User Manual

    41/120

    CONNECTIONS2

    WARNING

    RF signals may affect improperly installed or inadequately shieldedelectronic systems in motor vehicles. Check with the manufactureror its representative regarding your vehicle. You should also consult

    the manufacturer of any equipment that has been added to yourvehicle.

    WARNING

    An air bag inflates with great force. DO NOT place objects,including either installed or portable wireless equipment, in the areaover the air bag or in the air bag deployment area. If vehicleswireless equipment is improperly installed and the air bag inflates,serious injury could result.

    WARNING

    Turn off the device when in any area with a potentially explosiveatmosphere. Observe restrictions and follow closely any laws,regulations, warnings and best practices on the use of radio equipmentnear fuel storage areas or distribution fuel areas, chemical plants orwhere some operation involves use of explosive materials.

    Do not store or carry flammable liquids, explosive gases or materialswith the device or its parts or accessories.

    Areas with a potentially explosive atmosphere are often, but notalways, clearly marked or showed.

    Sparks in such areas could cause an explosion or fire, resulting ininjury or even death.

    21

  • 8/13/2019 Kyman User Manual

    42/120

    KYMAN3

    3 USE AND FUNCTIONING

    The use of the Kyman depends on the application software loaded. However thereare several parameters that can be set and utilities that can be used to perform somebasic functions such as data capture, communications, file management, etc.

    3.1 STARTUP

    To turn on the Kyman, please insert a charged battery or connect the externalsupply.

    If the mobile computer was left without any power for more than a few days, thebootstrap will start and the screen will appear as black for a few minutes. Please, bepatient and wait a while. Once the bootstrap has been completed, you will see theWindows CE/ Windows Mobile desktop on the screen.

    If instead the mobile computer was left without a power source for a smaller amountof time, it will resume to the status it had before the power was removed. In this caseyou will need to use the ON/OFF key to turn on the mobile computer.

    As soon as the PDA is on, the Windows CE/ Windows Mobile desktop screen willappear. Wait a few seconds before starting any activity so that the PDA completes itsstartup procedure.

    START MENU

    RIGHTSOFTKEY

    LEFTSOFTKEY

    Windows CE Desktop Windows MobileToday Screen

    22

  • 8/13/2019 Kyman User Manual

    43/120

  • 8/13/2019 Kyman User Manual

    44/120

    KYMAN3

    3.2 WINDOWS MOBILE WELCOME WIZARD

    In Windows Mobile, at the very first Kyman startup, following a cold boot orfollowing a registry restore to default values, the PDA startup (see par. 3.1) is

    preceded by the Welcome Wizard.

    Welcome Wizard Screen

    The Welcome Wizard allows the user to calibrate the touch screen (see par. 3.8.6)and to configure an email account and a password to protect the terminal.

    Touch Screen Calibration Screen

    24

  • 8/13/2019 Kyman User Manual

    45/120

  • 8/13/2019 Kyman User Manual

    46/120

    KYMAN3

    3.4 DATA CAPTURE

    To capture data first of all select the barcode icon on the bottom-right side of thedisplay and tap the Capture menu item, then proceed with the following directions.

    To configure and enable data capture parameters refer to par. 3.7.

    3.4.1 Laser Data Capture

    To scan barcodes, point the Kyman laser model onto the code from a distancewithin the reading range while pressing the SCAN key. See the reading diagrams inpar. 5.2 for the reading range of your model.

    The lighted band emitted by the laser must completely intercept the barcode as

    shown in the figure below. If enabled, the emission of an acoustic signal will indicatethat the scan has taken place correctly.

    26

  • 8/13/2019 Kyman User Manual

    47/120

    USE AND FUNCTIONING3

    3.4.2 Imager Data Capture

    To read a 1D or 2D code, simply point the Kyman Imager model onto the codefrom a distance within the reading range (See par. 5.1, section Kyman Imager

    Optical Features) and press the SCAN key.

    The Kyman Imager uses an intelligent aiming system pattern similar to those oncameras, which indicates the field of view which should be positioned over the code:

    Aiming System

    If the aiming system pattern is centered over the entire symbology as shown in thefollowing figure, either wait for the timeout or release the Scan key to capture the

    image.

    27

  • 8/13/2019 Kyman User Manual

    48/120

    KYMAN3

    A red beam illuminates the code, which is captured and decoded. You will get a goodread.

    Linear barcode 2D Matrix symbol

    BX3

    Relative Size and Location of Aiming System Pattern

    The field of view changes its size as you move the reader closer or farther away fromthe code. The field of view indicated by the aiming system pattern will be smallerwhen the Kyman Imager is closer to the code and larger when it is farther from thecode.

    Symbologies with smaller bars or elements (mil size) should be read closer to the

    unit. Symbologies with larger bars or elements (mil size) should be read farther fromthe unit. (See par. 5.1 for further details).

    3.4.3 RFID Data Capture

    To read or write a tag, place the Kyman so that the RFID emission window is infront of and almost in contact with the tag, then press the SCAN key or theapplication defined key.

    28

  • 8/13/2019 Kyman User Manual

    49/120

    USE AND FUNCTIONING3

    3.5 DESCRIPTION OF THE KEYS

    The Kyman provides two different keyboards, an alphanumeric keyboard and anumeric keyboard, having a total of respectively 53 and 36 keys.

    3.5.1 Alphanumeric Keyboard (53-key Model)

    The following image shows the Alhanumeric keyboard.

    29

  • 8/13/2019 Kyman User Manual

    50/120

  • 8/13/2019 Kyman User Manual

    51/120

    USE AND FUNCTIONING3

    Special Function Icons

    ICON FUNCTION

    After a yellow modifier key press, it opens the Start menu.

    After a yellow modifier key press, it opens the file manager.

    After a yellow modifier key press, it switches ON/OFF the keyboardbacklight.

    After a yellow modifier key press, it locks and unlocks the keyboard.

    31

  • 8/13/2019 Kyman User Manual

    52/120

    KYMAN3

    3.5.2 Numeric Keyboard (36-key Model)

    Main Keys Funct ionKEY FUNCTION

    It starts data capture.

    They let you move forwards, backwards, upwards ordownwards within text fields, scroll through a Menu list orbrowse among folder files.

    32

  • 8/13/2019 Kyman User Manual

    53/120

    USE AND FUNCTIONING3

    After a yellow modifier key press, they let you scroll thepages up and down.

    After a blue modifier key press, the blue arrows allowmoving forwards or backwards within the InternetExplorer browser pages.

    Yellow modifier: when pressed before a standard key, itenables the function printed in yellow above the key.

    Blue modifier: when pressed before a standard key, itenables the function printed in blue above the key.

    When pressed, it toggles the alphanumeric/numericmodes.

    It locks and unlocks the keyboard.

    It opens the Start menu.

    It powers the Kyman ON or OFF.

    After a blue modifier key press, it allows returning to theHome page.

    After a blue modifier key press, it allows ending a pagedownloading.

    After a blue modifier key press, it performs a pagerefresh.

    NOTE

    Once the Alpha mode has been entered, press the Alpha key againto exit this mode.

    33

  • 8/13/2019 Kyman User Manual

    54/120

    KYMAN3

    Keys from 1 to 9 share the following behavior scheme:

    BA

    A. Function of the key when directly pressedB. Function of the key when in Alpha mode.

    When in Alpha mode press the key until the desired letter is shown.The letter is entered if you wait for a short timeout or if you press a differentkey.

    Special Function Icons

    ICON FUNCTION

    It opens the file manager.

    It switches ON/OFF the keyboard backlight.

    34

  • 8/13/2019 Kyman User Manual

    55/120

    USE AND FUNCTIONING3

    3.5.3 Resett ing the Kyman

    Windows CE

    There are several reset methods for the Kyman.A warm boot terminates an unresponsive application and clears the working RAM,but preserves both the file system and the registry.A cold boot forces all applications to close and clears working RAM and files notresident on the persistent flash memory. Registry is restored from persistent memoryif available or returned to factory default.A Clean Boot restores the Kyman to factory configuration: registry and file systemreturn to factory default.

    Warm BootA warm boot closes all applications, clears the working RAM, but preserves the filesystem and registry. If an application "hangs" initiate a warm boot to terminate theapplication.To perform a warm boot, press these keys simultaneously:

    Cold BootA cold boot is a complete reset of the Kyman in which all applications are forciblyclosed and RAM is completely cleared. Registry is restored from persistent memory ifa saved copy is available (see 3.8.2)and RAM file system completely erased. Youwill lose any applications and data (registry too) which are not stored in persistentflash memory.A cold boot is necessary when the Windows CE operating system locks up and thewarm boot command does not work.To perform a cold boot, press these keys simultaneously:

    Clean BootA clean boot is a cold boot that causes the device to be restored to factoryconfiguration. The Kyman will reset to its factory configuration, clear the workingRAM and initialize the file system. You will lose any applications and data stored inpersistent flash memory. At the next startup the system will ask to recalibrate thetouch screen.

    35

  • 8/13/2019 Kyman User Manual

    56/120

    KYMAN3

    To perform a clean boot, follow these steps:

    1. Perform a Cold Boot (see Cold Boot).2. Quickly release all the keys when the screen goes black.

    3. Within 1 second press and hold down the Esc and 0 keys until the left orange ledstarts blinking.4. Release the Esc and 0 keys.5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean

    Boot and proceed with a Cold Boot.

    WarmBoot

    Cold Boot Clean Boot

    Registry Preserved Restored from flash(if available)

    Factory default

    Flash Disk(Backup Folder) Preserved Preserved Clean diskRAM FileSystem

    Preserved Reinitialized (factory default) Factory default

    CAUTION

    Before performing a reset, it is recommended to:

    - execute a system backup to keep your more important filesand applications persistent. See par. 3.10;

    - save the registry to non-volatile memory to guarantee thepersistence of the Windows configuration. See par. 3.8.2.

    Windows Mobile

    There are several reset methods for the Kyman.A warm boot terminates an unresponsive application and clears the working RAM,but preserves the file system. Registry are restored from persistent memory ifavailable or returned to factory default.A cold boot forces all applications to close reinitializing completely the system. It

    clears the working RAM, but the file system is preserved. Registry are restored frompersistent memory if available or returned to factory default.A clean boot restores the Kyman to a clean configuration: both the registry and thefile system return to a clean status that conform to factory default, unless the userhas installed an additional package.

    Warm BootA warm boot closes all applications and clears the working RAM, but preserves thefile system. Registry are restored from persistent memory if a saved copy is available(see Registry Applet, par. 3.8.2) or returned to factory default. If an application

    hangs, initiate a warm boot to terminate the application.To perform a warm boot, press and hold the following keys simultaneously:

    36

  • 8/13/2019 Kyman User Manual

    57/120

    USE AND FUNCTIONING3

    Cold BootA cold boot is a complete reset of the Kyman in which all applications are forciblyclosed and the RAM is completely cleared. Registry is restored from persistentmemory if a saved copy is available (see Registry Applet, par. 3.8.2). Applicationsand data stored on file system are preserved. A cold boot is necessary when theWindows Mobile operating system locks up and the warm boot command does notwork.To perform a cold boot, press and hold the following keys simultaneously:

    Clean BootA clean boot is a cold boot that causes the device to be restored to a cleanconfiguration. The Kyman will be reset to its factory configuration only if the userhas not installed any additional package. Please note that you will lose any

    applications and data stored in persistent flash memory.To perform a clean boot, follow these steps:

    1. Perform a Cold Boot (see Cold Boot).2. Quickly release all the keys when the screen goes black.3. Within 1 second press and hold down the Esc and 0 keys until the left orange led

    starts blinking.4. Release the Esc and 0 keys.5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean

    Boot and proceed with a Cold Boot.

    Warm Boot Cold Boot Clean BootRegistry Restored from

    flashRestored fromflash

    Clean configuration (no userconfig)

    FileSystem

    Preserved Preserved Clean Installation (no user files)

    37

  • 8/13/2019 Kyman User Manual

    58/120

    KYMAN3

    3.6 STATUS INDICATORS

    3.6.1 LED Status

    The Kyman provides three different LEDs signaling the mobile computer status.

    LED STATUS

    General Purpose

    (left-side)

    Green/Red This LED is available to the applicationprogram.

    Charging Status andBattery Low Warning

    Green constant It is constant once the charging processhas been completed.

    (right side) Red blinking When the mobile computer is poweredby the battery (not by the cradle nor bythe cable), this LED blinks red to signalthat the battery is running down.

    Red constant It is constant while charging.

    Orange blinking It blinks when a charging error hasoccurred, for example when a mobilecomputer without battery is connected

    to the external power or inserted into apowered cradle.

    Good Read

    (middle)

    Green It is constant for a configurable time tosignal that a successful read hasoccurred.

    38

  • 8/13/2019 Kyman User Manual

    59/120

    USE AND FUNCTIONING3

    3.6.2 Taskbar

    The Taskbar provides information about the time, the battery level, the keyboardfunction, and the decoding status.

    ICONS DESCRIPTION

    Time and Battery Icons

    It displays the time.

    In Windows CE, they are representative of five differenticons indicating the battery level. The icon is partiallygreen when the power left is >20% and partially redcolored when the power left is

  • 8/13/2019 Kyman User Manual

    60/120

    KYMAN3

    Windows CE Taskbar

    Windows Mobile Taskbars

    40

  • 8/13/2019 Kyman User Manual

    61/120

    USE AND FUNCTIONING3

    3.7 DATA CAPTURE CONFIGURATION

    From the Windows CE Taskbar, tap the "Decoding" icon to open a dropdown menu.Decoding can also be accessed from the Control Panel.

    By selecting the Info item from this drop-down menu you can access informationabout the Scanner and the Software; the Configure item opens the configurationapplet (Data Capture Configuration Window), while Capture accesses the datacapture applet (Data Capture Window), which enables code reading.The last menu item (Wedge) enables Wedge Emulation.

    From the Windows Mobile Start menu, tap Settings -> System -> Data Capture. The"Data Capture" icon opens the configuration applet (Data Capture ConfigurationWindow).

    Windows CE Windows Mobile

    3.7.1 Configure

    The Configuration applet contains the barcode scanning configuration parameters ina directory tree structure. The available barcode parameters are divided into twogroups: Reader Parameters and Scan Parameters.

    The Reader Parameters depend on the type of scanner module installed on themobile computer and allow barcode configuration (i.e. enable/disable Code 39, checkdigit control, etc.).

    41

  • 8/13/2019 Kyman User Manual

    62/120

    KYMAN3

    The Scan Parameters are common to all scanner modules and allow control of thescanning device (i.e. beeper control, LED control, laser timeout, etc.).

    Each Data Capture screen window corresponds to a branch of the tree, and the

    name of the current branch is displayed at the bottom of each screen window.

    Data Capture Configuration Window

    The screen format shows two columns where the left column indicates branches or

    parameters. Branches have three dots in the right column (...). You can navigatethrough the tree structure using the stylus or keyboard arrows directly on the itemfield or from the menu.

    Parameters have their corresponding current values in the right column. You can editparameter values using the stylus or keyboard arrows directly on the item field orfrom the menu. To change a value for example, select the line of the value to bechanged, choose Edit from the Parameter Menu then choose a new value from thevalues listed in the box (see following figures).

    42

  • 8/13/2019 Kyman User Manual

    63/120

    USE AND FUNCTIONING3

    Selecting Data Capture Setup Parameters

    Alternatively using the stylus, you can tap once directly on the value on the rightcolumn; continue tapping until the desired value is reached.

    To activate a new configuration select the File ->Save Menu to send the newconfiguration to the barcode decoding software and save the new configuration. Thiswill save the configuration to non-volatile memory preventing loss at the next systemreset.

    43

  • 8/13/2019 Kyman User Manual

    64/120

    KYMAN3

    Reader Parameters

    The barcode reading parameters and values are dependent upon the type of scannermodule mounted in your mobile computer. For a detailed list of parameters and of

    their configuration procedures, please refer to the SDK Help file on the CD.

    Scan Parameters

    The Scan Parameters are common to all scanner modules and allow control of thescanning device. The Scan parameters are described as follows:

    ScanTimeout: the maximum time, in milliseconds, during which the scanner remainson without decoding any barcode.

    BeepType: if set to dual tone, the good read beep is a sequence of high and lowpitch sounds. If set to monotone, the beep is a single pitch sound.

    BeepDuration: the time interval, in milliseconds, during which the beeper will soundwhen the scanner reads a code. To disable the beeper, set this value to 0.

    BeepFrequency: determines the frequency in Hertz of the beeper.

    GoodReadSound: is the filename of a .wav file played when the scanner reads acode.

    LedDuration: the length of the good-read led pulse, in milliseconds.

    LedPulses: the number of times the good-read led pulse is emitted when thescanner reads a code.

    GreenSpotDuration: the length of the green spot pulse, in milliseconds

    ContinuousMode: disables the effect of the ScanTimeout parameter.

    KeyboardEmulation: if enabled all scanned data are transformed into keyboardevents and can therefore be displayed and saved to a file as if input from the PDAkeyboard. If set to Yes (Clipboard), it copies the scanned data to the systemclipboard.

    SoftTrigger: when enabled, the laser can be turned on/off by the applicationsoftware.

    ScanAlwaysOn: enables the scanner for barcode reading independently from theapplication software. If set to Disabled after read, it disables the reading after areading attempt. In case the scan button is accidentally pressed, this selectionprevents the driver from decoding new data while the application is still elaboratingprevious data.

    44

  • 8/13/2019 Kyman User Manual

    65/120

  • 8/13/2019 Kyman User Manual

    66/120

    KYMAN3

    BARCODE SYMBOLOGYSPECIFIC READERPARAMETERS

    Laser Models(XXX-1XX,XXX-4XX)

    ImagerModels

    (XXX-7XX)

    Laser Extra LongRange Models

    (XXX-6XX)UPC A Enabled EnabledUPC E Enabled EnabledEAN 8 Enabled EnabledEAN 13 Enabled

    *

    EnabledUPC E1 DisabledEAN Bookland DisabledUPC/EAN/JAN EnabledCode 39 Enabled Enabled EnabledCode 39 Full ASCII Disabled Disabled DisabledCode 32 Disabled DisabledCode 39 Trioptic Disabled

    2/5: Interleaved Enabled Enabled Enabled2/5: Industr ial Disabled Disabled2/5: Matrix DisabledCode 128 Enabled Enabled EnabledEAN 128 Enabled Disabled EnabledISBT 128 DisabledCodabar Enabled Enabled DisabledRSS Disabled

    * In the Imager models these codes may only be enabled or disabled as a group by theUPC/EAN/JAN family selection (see a few lines below in the same table).

    BARCODE SYMBOLOGYSPECIFIC READER PARAMETERS

    Laser Models(XXX-1XX,XXX-4XX)

    ImagerModels

    (XXX-7XX)

    Laser ExtraLong Range

    Models(XXX-6XX)

    MSI Enabled DisabledPlessey DisabledCode 93 Disabled Enabled DisabledCode 11 DisabledPDF - 417 Enabled

    Data Matrix EnabledQR EnabledPOSTNETPLANETJapan PostAustralia PostKIX CodeRoyal Mail Code (RM4SCC)

    Disabled*

    * These codes may be enabled individually but are disabled as a group.

    46

  • 8/13/2019 Kyman User Manual

    67/120

    USE AND FUNCTIONING3

    3.7.2 Capture

    The Data Capture applet (Capture) enables code reading.

    Data Capture Window

    Data Capture can also be enabled through the Configuration applet by selecting File->Scanner from the main menu, or by enabling the parameter Scan Always On in theScan Parameters branch.

    Enabling the Data Capture

    47

  • 8/13/2019 Kyman User Manual

    68/120

    KYMAN3

    3.8 CONTROL PANEL

    From the Windows CE Desktop, double tap on the "My Device" icon and then doubletap on the "Control Panel" icon to open the Windows CE control panel main window.

    The Control Panel can also be launched from Start ->Settings ->Control Panel.

    APPLET programs are displayed as icons; one icon corresponds to each APPLET.

    Windows CE Control Panel

    From the Windows Mobile Start menu, tap Settings. A three tab dialog opens:Personal, System, Connections.

    APPLET programs are displayed as icons; one icon corresponds to each APPLET.

    Windows Mobile Control Panel

    48

  • 8/13/2019 Kyman User Manual

    69/120

    USE AND FUNCTIONING3

    3.8.1 Buttons

    The BUTTONS Applet allows assigning desired applications to be launched by oneof the function keys (F1, F2, F3, F4).

    You can also select to wake up the terminal by the SCAN key and trigger key (forDatalogic Kyman-GUN only).

    Windows CE Buttons Icon Windows Mobile Buttons Icon

    On a Windows Mobile unit the user is also able to assign a shortcut to a function key.The default programs/shortcut assigned to the function keys on Windows Mobile arethe following:

    F1 : select the Left Soft KeyF2 : open the Start MenuF3 : open the Today ScreenF4 : select the Right Soft Key

    To configure the way up/down and the rest of keys control repeats, use the Up/DownControl applet (Start -> Settings -> Personal -> Buttons -> Up/Down Control).

    49

  • 8/13/2019 Kyman User Manual

    70/120

    KYMAN3

    3.8.2 Registry

    The REGISTRY ADMIN applet provides management of Windows CE/ WindowsMobile registry.

    From the Windows CE control panel main window, select the REGISTRY ADMINapplet by double tapping the Registry Admin icon.

    From the Windows Mobile Start menu, tap Settings -> System ->Registry. Select theREGISTRY ADMIN applet by tapping the Registry Admin icon.

    The Registry Administration Main window appears. Two functions are available:

    - Save Registry allows permanently saving the Windows configuration (example:custom configuration of screen desktop background color, or network adapterconfiguration) to non-volatile memory (SAVE button).

    - Restore Default Registry allows restoring the initial factory default configuration(Restore Default button). After restoring the factory default configuration, youmust perform a warm boot (see par. 3.5.3).

    Saving the registry to non-volatile memory guarantees the persistence of theWindows configuration in case of battery pack replacement and in case of a coldboot.

    Registry Administration Window

    50

  • 8/13/2019 Kyman User Manual

    71/120

    USE AND FUNCTIONING3

    3.8.3 Files Admin

    The FILES ADMIN applet enables control of the permanence of files in the WindowsCE System Folder.

    Because Windows Mobile mounts the entire file system in persistent store (ratherthan using RAM), it provides both users and applications with a reliable storageplatform even in the absence of battery power. The FILES ADMIN applet is thereforenot necessary.

    Two functions are available on the Files Admin Main window by means of twobuttons:

    Files Admin Main Window

    Save Session:with this button all files will be permanently saved in the \Windowsdirectory in non-volatile memory. This function guarantees the steady maintenance ofevery file produced during the current working session - even of sub-directories andrelevant files - with the exception of the files belonging to the FLASH image.These current working session files will be backed-up in the \Backup\Windows

    directory.At the next cold boot, the files previously saved in the \Backup\Windows directory willbe restored to the Windows directory (see par. 3.10).

    Safe Setup: with this button, the installation of software programs will be saved tonon-volatile memory (Backup directory). Before doing this, it will be checked that theBackup directory has enough space to save the files. If the directory space is notenough, an error message will be shown and the program will exit the Safe Setupfunction.

    Two activating procedures are available for Safe Setup:

    51

  • 8/13/2019 Kyman User Manual

    72/120

    KYMAN3

    - Select an installation file (for example, a .CAB cabinet file) from the Safe Setupmask.

    Safe Setup First Mask

    Then select \Windows or a relevant sub-directory in the path box. Then, SafeSetup will recognize the new files and directories present in the \Windowsdirectory, and will copy them to the \Backup\Windows directory. At the next coldboot, these files will be restored (see par. 3.10).

    - Simply skip the first mask either by closing it or by pressing the ESC key. Whenit closes, a new mask will pop up: it will enable any type of installation (evenremote ones like ActiveSyncinstallations). Make sure the installation directoryis \Windows or one of its sub-directories. After installation, tap OK: Safe Setupwill save the new files in the \Backup\Windows directory.

    -

    Safe Setup Second Mask

    52

  • 8/13/2019 Kyman User Manual

    73/120

    USE AND FUNCTIONING3

    3.8.4 Wireless Communications

    The WIRELESS COMMUNICATIONS applet provides management of the Wi-FiCard, the Bluetoothand GSM/GPRS modules.

    Windows CE Wireless CommunicationsIcon

    Windows Mobile Connectivity Icon

    If the PDA supports Windows CE, select the WIRELESS COMMUNICATIONS appletby double tapping the Wireless Communications icon. The following window will

    appear:

    Windows CE Wireless Communications Window

    53

  • 8/13/2019 Kyman User Manual

    74/120

    KYMAN3

    If the PDA supports Windows Mobile, the Wireless Manager application managesaccess to wireless connections.The 'Wireless Manager' is a sort of 'Control Panel' for Bluetooth and phonemodules. From here it's possible to turn on or off Bluetooth and phone radio stacks.

    Open the Wireless Manager by tapping Start -> Settings -> Wireless Manager, or bytapping the Connectivity icon located at the top of the screen. The following windowwill appear:

    Windows Mobile Wireless Communications Window

    To turn on/off the WiFi radio open the Wi-Fi power applet by tapping Start -> Settings-> System -> Power -> Wi-Fi:

    54

  • 8/13/2019 Kyman User Manual

    75/120

    USE AND FUNCTIONING3

    3.8.5 Ethernet Settings

    Windows CE Ethernet Cradle

    Datalogic Kyman can be connected to an Ethernet network by inserting it into theDatalogic Kyman Ethernet Multi Cradle.

    When correctly inserted into the Ethernet Multi Cradle, the Ethernet driver installedon the mobile computer will automatically run, and using the DHCP service, willdynamically assign the IP Address.

    1. From the Datalogic Kyman open Internet Explorer>Internet Options and checkuse LAN no autodialthen OK.

    2. From the Datalogic Kyman > Explorer, enter the IP address or the PCname in the address bar. You may be required to enter your networkusername and password. The LAN connection will take place and you willbe able to see the PC shared foldersand exchange files.

    If your network provides Internet Service and does not use a proxy server you candirectly access the Internet. Otherwise set the internet proxy parameters according toyour network settings.

    55

  • 8/13/2019 Kyman User Manual

    76/120

  • 8/13/2019 Kyman User Manual

    77/120

    USE AND FUNCTIONING3

    Windows Mobile Ethernet Cradle

    Before using the ethernet cradle you have to un-check the 'COM1 Enable' option onthe 'System Configuration' window (Start -> Programs -> System Configuration) and

    re-boot the unit.

    For internet browsing through the ethernet cradle ensure that programs thatautomatically connect to the internet should connect using 'My Work Network' -> goto Start -> Settings -> Connections -> Connections -> Advanced -> Select Networks:

    then ensure that the USB/Ethernet Adapter card connects to Work -> go to Start ->Settings -> Connections -> Connections -> Advanced -> Network Cards:

    57

  • 8/13/2019 Kyman User Manual

    78/120

    KYMAN3

    3.8.6 Stylus Calibration

    You might need to recalibrate the touch screen (i.e. when you attempt to select oneitem with the stylus, another item is erroneously selected).

    To recalibrate the touch screen on Windows CE, complete the following steps:1. Select Start > Settings > Control Panel > Stylus to open the Stylus

    Properties dialog as shown in Figure 1.2. Adjust Double-Tapsensitivity if needed or desired.3. Select the Calibrationtab to open the Calibrationapplication.

    Figure 1

    4. Tap Recalibrateto open the Calibrationscreen shown in Figure 2.5. Carefully press and briefly hold stylus on the center of the target. Repeat as the

    target moves around the screen. Press the key to cancel the styluscalibration.

    6. Press the key or tap the screen to accept the new calibration settings.Press the key to keep the old settings.

    7. New calibration settings are persistently saved in registry.

    58

  • 8/13/2019 Kyman User Manual

    79/120

    USE AND FUNCTIONING3

    Figure 2

    To recalibrate the touch screen on Windows Mobile, complete the following steps:1. Select Start > Settings > System > Screen to open the Screen

    Settings dialog as shown in Figure 3.

    Figure 3

    59

  • 8/13/2019 Kyman User Manual

    80/120

    KYMAN3

    2. TapAl ign Screen to open the Calibration screen shown in Figure 4.3. Carefully press and briefly hold stylus on the center of the target. Repeat as the

    target moves around the screen. Press the key at any time to cancel thestylus calibration.

    4. By completing the calibration procedure you implicitly accept the new calibrationsettings.5. New calibration settings are persistently saved in registry.

    Figure 4

    60

  • 8/13/2019 Kyman User Manual

    81/120

    USE AND FUNCTIONING3

    Startup stylus calibration on Windows CE

    When starting the terminal, a stylus calibration screen comes up if valid calibrationsettings are not available. This happens in the following circumstances:

    1. At the first startup of the terminal.2. After restoring registry default settings using the applet Registry Admin andperforming a warm boot.

    3. After a Clean Boot.4. After a Firmware Update(see par. 3.11 ).

    Startup stylus calibration on Windows Mobile

    When starting the terminal, a Welcome Wizard (with Stylus Calibration) comes up if

    valid calibration settings are not available. This happens in the followingcircumstances:1. At the first startup of the terminal.2. After restoring registry default settings using the applet Registry Admin and

    performing a boot.3. After a Clean Boot.

    61

  • 8/13/2019 Kyman User Manual

    82/120

    KYMAN3

    3.8.7 Volume Sett ings

    From the Windows CE control panel main window, select the VOLUME SETTINGSapplet by double tapping the Volume Settings icon.

    From the Windows Mobile Start Menu, tap Settings -> System -> Volume Settings.Select the VOLUME SETTINGS applet by tapping the Volume Settings icon.

    The Volume Settings applet allows managing the audio features and appears asfollows:

    Volume Settings Window

    The window is divided into three tabs:

    - Outputtab: allows setting the volume for each audio profile;

    - Inputtab: allows setting the microphone recording volume;

    - Cradle tab: allows selecting the cradle type and managing the vehicle cradleheadset functioning.

    The Status bar always displays the current audio profile, which is activatedautomatically (by the device) or manually (by the user). Available profiles are:

    -

    Speaker: it is the typical profile reproducing audio through the mobile computerspeaker;

    - Cradle: it is automatically activated as soon as the mobile computer is insertedinto the vehicle cradle. Audio is reproduced by the vehicle cradle loudspeaker.

    - Headset: it is automatically activated as soon as a headset is directly connectedto the mobile computer. In case the device is inserted into the vehicle cradle andthe headset is connected to the cradle, this profile must be manually activatedthrough the dedicated button (refer to Cradle Tab paragraph). When this profileis active, the speaker does not work;

    62

  • 8/13/2019 Kyman User Manual

    83/120

    USE AND FUNCTIONING3

    - GSM: it is automatically activated each time a phone-call is started. It is notavailable when using the cradle loudspeaker (in this caseCurrent Profile = Cradle).

    63

  • 8/13/2019 Kyman User Manual

    84/120

    KYMAN3

    Output Tab

    It allows setting the volume for each audio profile:

    The Master Volume slider allows settingthe volume used by all audio profiles. Inaddition, it is possible to attenuate thevolume for each single profile through thededicated slider.

    Input Tab

    It allows setting the microphone recording volume:

    The Record Gain slider allows settingthe recording volume, while the EnablePreamplifier check box enables/disablesthe preamplifier (this option is notselectable when Current Profile = Cradle

    or GSM).

    Cradle Tab

    It allows selecting the cradle type and managing the vehicle cradle headsetfunctioning:

    64

  • 8/13/2019 Kyman User Manual

    85/120

    USE AND FUNCTIONING3

    Two radio buttons allow selecting the type of cradle to be used.

    Check the Cradle desk, AC plug or none radio button, if using a cradle differentfrom the vehicle cradle or an AC adapter plug.

    If using a vehicle cradle, check the related radio button.

    NOTE

    By inserting the mobile computer into the cradle when the Cradlevehicle radio button is checked, the mobile computer speaker isdeactivated and audio will be reproduced through the vehicle cradlespeaker or headset.

    By selecting the Cradle Vehicle check box, a further button will appear allowing toenable the headset profile when using the vehicle cradle. If pressed, the button

    displays the headset icon in gray until the device is inserted into the vehicle cradle.Once inserted, the headset icon turns to green and the device activates the headsetprofile (refer to the following figures). Actually, the headset is ready to reproduceaudio as soon as it is connected to the cradle jack:

    WARNING

    Do not use the vehicle cradle headset if the headset button is

    disabled, since it may cause hearing damage.

    65

  • 8/13/2019 Kyman User Manual

    86/120

    KYMAN3

    3.9 WINDOWS CONNECTIONS

    To connect Kyman to another device (i.e. Host PC) from Windows, severalprograms are available. These programs require specific electrical connections in

    order to function properly.

    3.9.1 Microsof t Act iveSync

    MicrosoftActiveSyncgives you the possibility to connect your desktop computer toyour Kyman and synchronize the information on them. Synchronization comparesthe data on the Kyman with that on the desktop computer and updates bothcomputers with the most recent information.

    With ActiveSync, it is possible to:- Back up and restore Kyman data.- Copy files between Kyman and desktop computer.- Synchronize files by selecting a synchronization mode.

    You can establish an ActiveSyncconnection to your Kyman through the followingelectrical interfaces:

    RS232either directly or through the Kyman Single Cradle

    USBeither directly or through the Kyman Single Cradle

    Bluetooth(see par. 3.9.2)

    It is possible to constantly synchronize while connected to a desktop computer or,alternatively, synchronization can be performed only when the synchronize commandis chosen. You can select which information types are synchronized and control howmuch data is synchronized.

    NOTE

    By default, ActiveSyncdoes not automatically synchronize all types

    of information. Use ActiveSync

    options to turn synchronization onand off for specific information types.

    For example:Synchronize Microsoft Word and Microsoft Excel files between the Kyman and thedesktop computer. The files will automatically be converted to the correct format.

    66

  • 8/13/2019 Kyman User Manual

    87/120

    USE AND FUNCTIONING3

    NOTE

    In Windows Mobile before using the ActiveSync follow the directionsdescribed in 2.1

    NOTE

    Visit the following Microsoft Web site for the latest in updates, technicalinformation, and samples:http://www.microsoft.com/windowsmobile/resources/downloads

    ActiveSync Remote

    NOTE

    Microsoft ActiveSyncRemote is no longer supported in WindowsCE. For backward compatibility you can download it from theinternet. We suggest enabling the FTP Server and connecting to anFTP Client. See par. 3.9.3.

    67

  • 8/13/2019 Kyman User Manual

    88/120

    KYMAN3

    3.9.2 Bluetooth Manager Device Setup

    Windows CE Bluetooth Manager Device Setup

    In order to enable a Bluetoothdevice for communication with the Kyman you mustperform the discovery procedure and enable the device as follows:

    1. Place the Bluetoothdevice within the range of the Kyman (10 meters).

    2. From the Control Panel main window doubletap on the Bluetooth applet to open theBluetoothManager Device window:

    3. Tap on the Me button to enter the relatedwindow; then, tap on the ON button toactivate the Bluetooth module. The moduleactivation may be also performed by using theWIRELESS COMMUNICATION applet asdescribed in par. 3.8.4.

    By tapping on the HW Details and SWDetails buttons, information about the mobilecomputer Bluetooth hardware and softwarewill be displayed, while the EnableEncryption button starts encryption of theBluetooth communication data. If tapping onthe Close button the Bluetooth ManagerDevice window will be closed.

    68

  • 8/13/2019 Kyman User Manual

    89/120

    USE AND FUNCTIONING3

    4. Tap on the Discovery button to enter therelated window; then, tap on the Scanbutton to run the Discovery procedure.

    Once the Discovery procedure has beencompleted, select the desired Bluetoothdevice from the list. It is also possible to digit(12 hexadecimal digits) the Bluetooth

    address of the desired device by tapping onthe Add button. The Clear button deletesall discovered devices from the list.

    5. Once the desired Bluetooth device has beenselected, tap on the Connection Wizardbutton to enter the related window whereselecting the connection type to be used forcommunication with the Bluetooth device.

    The Serial Port button startscommunication through the Bluetooth serialport COM 5 (typically used for connectionwith GPS devices).The Printer button starts communicationwith a printer through the Bluetooth serialport COM 5.The Kbd Emulation button allowsconnection with a barcode reader using thekeyboard emulation.The ActiveSync button startscommunication with a PC equipped with a

    Bluetooth antenna and the relatedActiveSync.

    6. Hide the Bluetooth Manager Device window by tapping on the iconavailable on each window or close it through the Close button available in theMe window (see step 3 of this procedure).

    69

  • 8/13/2019 Kyman User Manual

    90/120

    KYMAN3

    Windows Mobile Bluetooth Manager Device Setup

    Before turning on Bluetooth, ensure that the two devices are within close range andthat both Bluetooth-enabled devices are discoverable.

    1. Tap Start -> Settings -> Connections tab.

    2. Tap Bluetooth > Mode

    3. Select or clear the Turn on Bluetooth check box:

    NOTE

    By default, Bluetooth is turned off. If you turn it on, and then turn offyour