Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

66
Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012

Transcript of Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Page 1: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Karl Slifer University of New Hampshire

Jefferson LabUser Group Meeting

6/5/2012

Page 2: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

This talk

Brief review of Physics Motivation for g2p (E08-027)

Review of the Installation and Experimental Run

Status of the Analysis

Online Results

Page 3: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Q2 = Momentum transfer squared

Incident beam

Target

Detectors

scatte

red

Target “shrapnel” not detected

Important Kinematic Variables

W = Invariant Mass of target System

E

E’

Bjorken variable

Page 4: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Inelastic ScatteringInelastic Scattering

W

1st order Feynman diagram

Inclusive Cross Section

° *

Compositeness of target characterizedby the Structure Functions

Spin-1/2 Target

E

P

E’

W

q

Page 5: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Inelastic ScatteringInelastic Scattering

W

1st order Feynman diagram

Inclusive Polarized Cross Section

° *

Two additional Structure Functions needed

Spin-1/2 Target

E

P

E’

W

q

Page 6: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Experimental TechniqueExperimental Technique

− −

Page 7: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Proton g2 data from SLAC

x2g

2

Q2 ≈ 5 GeV2

Page 8: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Proton g2 data from SLAC

Precision does not allowunambiguous HT extraction

x2g

2

Leading Twist

Q2 ≈ 5 GeV2

Page 9: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Proton g2 data from JLAB SANE

Leading Twist

Q2 ≈ 3-6 GeV2

Very PrelimStat Errors

x2g

2

Page 10: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

RSS Experiment (Spokesmen: Rondon and Jones)

K.S., O. Rondon et al. PRL 105, 101601 (2010)

consistent with zero => low x HT are small in proton.

non-zero by 2.6

=>Significant HT at low x needed to satisfy Neutron BC sum rule.

(proton)

(neutron)

Q2 = 1.3 GeV2

Page 11: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

H.Burkhardt and W.N. Cottingham Annals Phys. 56 (1970) 453.

Assumptions:

the virtual Compton scattering amplitude S2 falls to zero faster than 1/x

g2 does not behave as (x) at x=0.

R.L. Jaffe Comm. Nucl. Part. Phys. 19, 239 (1990)

Discussion of possible causes of violations

“If it holds for one Q2 it holds for all”

BC Sum Rule

Page 12: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

BC Sum RuleBC Sum Rule

P

N

3He

BC satisfied w/in errors for JLab Proton2.8 violation seen in SLAC data

0<x<1

Mostly unmeasured

Page 13: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

GeneralizedSpin Polarizabilities

Page 14: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Forward Spin Polarizabilities Forward Spin Polarizabilities Neutron

PRL 93: 152301 (2004)

Heavy Baryon ÂPT CalculationKao, Spitzenberg, VanderhaeghenPRD 67:016001(2003)

Relativistic Baryon ÂPTBernard, Hemmert, MeissnerPRD 67:076008(2003)

Dramatic Failure of ChiPT

Page 15: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Plots courtesy of V. Sulkosky

New Data on the Neutron Polarizabilities

Page 16: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Plots courtesy of V. Sulkosky

New Data on the Neutron Polarizabilities

Large discrepency with LT remains

Page 17: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Pro

ton

PLB672 12, 2009

Calculations also fail for proton 0

Proton 0Proton 0

Page 18: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

LT Spin PolarizabilityLT Spin PolarizabilityKochelev & Oh. arxiv:1103.4892. (2011)Improves agreement with neutron,

Neutron

Page 19: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Proton

LT Spin PolarizabilityLT Spin Polarizability

No data yet on proton LT polarizability

Kochelev & Oh. arxiv:1103.4892. (2011)Improves agreement with neutron,

Neutron

Page 20: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Applications to Bound State Q.E.D.Applications to Bound State Q.E.D.

nucleus ≈ 10-15

Atom ≈ 10-10

The finite size of the nucleus plays a small but significant role in atomic energy levels.

Page 21: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

nucleus ≈ 10-15

Atom ≈ 10-10

The finite size of the nucleus plays a small but significant role in atomic energy levels.

Hydrogen HF Splitting

Applications to Bound State Q.E.D.Applications to Bound State Q.E.D.

Page 22: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

nucleus ≈ 10-15

Atom ≈ 10-10

The finite size of the nucleus plays a small but significant role in atomic energy levels.

Hydrogen HF Splitting

Friar & Sick PLB 579 285(2003)

Applications to Bound State Q.E.D.Applications to Bound State Q.E.D.

Page 23: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Elastic Scattering

Structure dependence of Hydrogen HF Splitting

Z=-41.0±0.5ppm

Page 24: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Inelastic

Structure dependence of Hydrogen HF Splitting

Nazaryan,Carlson,Griffieon PRL 96 163001 (2006)

pol≈ 1.3±0.3 ppm

0.2265 ppm

Elastic piece larger but with similar uncertainty

integral of g1 & F1

pretty well determined from F2,g1 JLab data

Z=-41.0±0.5ppm

Page 25: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Inelastic

Structure dependence of Hydrogen HF Splitting

Nazaryan,Carlson,Griffieon PRL 96 163001 (2006)

pol≈ 1.3±0.3 ppm

0.2265 ppm

Elastic piece larger but with similar uncertainty

weighted heavily to low Q2

Page 26: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Hydrogen Hyperfine StructureHydrogen Hyperfine Structure

E08-027

Dominated by this region due to Q2 weightingDominated by this region due to Q2 weighting

assuming CLAS model with 100% error

Inte

gran

d of

¢2

Page 27: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Hydrogen Hyperfine StructureHydrogen Hyperfine Structure

E08-027

Dominated by this region due to Q2 weightingDominated by this region due to Q2 weighting

But, unknown in this region:

MAID Model

Simula Model

Inte

gran

d of

¢2

So 100% error probably too optimistic

E08-027 will provide first real constraint on 2

assuming CLAS model with 100% error

Page 28: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

PSI measurement of the RMS proton radius

Spectroscopic measurement of the energy splitting of the

2S1/2-2P1/2 levels in muonic hydrogen (Lamb shift).

Page 29: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Proton Charge Radius from P lamb shift disagrees with eP scattering result by about 6%

I. Sick (Basel) : “What gives? I don’t know”. “Serious discrepency” [ELBA XI, Nature.com]

C. Carlson (W&M) : “Something is missing, this is very clear.” [Nature.com]

P. Mohr (NIST) : “would be quite revolutionary.” [L.A. Times.]

B. Odom (N.Western) : “...very surprised to find strong disagreement.” [N.P.R.]

J. Flowers (N.P.L.) “...could mean a complete rethink of QED”. [National Geographic]

“...opens door for a theorist to come up with next [NY Times] theoretical leap, and claim their Nobel prize”.

<Rp> = 0.84184 ± 0.00067 fm Lamb shift in muonic hydrogen

<Rp> = 0.897 ± 0.018 fm World analysis of eP scattering

<Rp> = 0.8768 ± 0.0069 fm CODATA world average

R. Pohl et.al Nature, July 2010

I. Sick PLB, 2003

Page 30: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.
Page 31: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.
Page 32: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Polarizability : Integrals of g1 and g2 weighted by 1/Q4

Zemach radius : Integral of GEGM weighted by 1/Q2

Dominated by Kinematic region of E08-027 and E08-007

Page 33: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

E08-027 : Proton g2 Structure Function

Primary Motivation

Proton g2 structure function has never been measured at low or moderate Q2.

We will determine this fundamental quantity at the lowest

possible Q2

This will help to clarify several outstanding puzzles

Hydrogen HyperFine Splitting : Lack of knowledge of g2 at low Q2 is one of the leading uncertainties.

Proton Charge Radius : also one of the leading uncertainties in extraction of <Rp> from H Lamb shift.

A. Camsonne J.P. Chen D. Crabb K. Slifer

Page 34: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Experimental Technique Inclusive Polarized Cross Section differences

Major Installation in Hall A

Polarized proton targetupstream chicanedownstream local dump

Low current polarized beamUpgrades to existing Beam Diagnostics to work at 85 nA

Lowest possible Q2 in the resonance regionSepta Magnets to detect forward scattering

Page 35: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Major New Installation in Hall A

Page 36: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

A few minor mechanical setbacks delayed the start of the experiment by 149 days

Redesigned/Replaced/RepairedPolarized target magnetChicane bellowsRight Septa MagnetBoth Septa Max FieldLocal Dump CoolingHarp wires

Page 37: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

A few minor mechanical setbacks delayed the start of the experiment by 149 days

Lab Support in dealing with these issues has been

Greatly Appreciated!

Grad Student and Post-Doc response also amazing

Redesigned/Replaced/RepairedPolarized target magnetChicane bellowsRight Septa MagnetBoth Septa Max FieldLocal Dump CoolingHarp wires

Page 38: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Kinematic Coverage

Mp < W < 2 GeV

0.02 < Q2 < 0.2 GeV2

Reduced kinematics

Page 39: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Projections

LT Spin Polarizability BC Sum Integral

Page 40: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Form factors are normalized such that:

Elastic Scattering,

ChargeMagnetic moment

Page 41: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Expansion at low Q2 gives

RMS charge radius

the slope of GE at Q2=0 determines the “size” of the proton.

FF’s represent the momentum-space charge and magnetization distributions

=>fourier transforms of the coordinate space distributions. (non-rel limit).

Page 42: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Latest world analysis(Unpublished)

<Rp> = 0.870 +- 0.010 fm

GE/GD

Best value of <Rp> fromelastic proton scattering

<Rp> = 0.897 ± 0.018 fm

I. Sick PLB 2003

Proton GE Data at low Q2

Normalized to the dipole form

Page 43: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Super-ratio of left/right Asymmetries:

E08-007 : GE/GM

G. Ron*, D. Higintbothan, R. GilmanJ. Arrington, A. Sarty, D. Day

Page 44: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Projected Results

Page 45: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Online Results

2.2 GeV, 90 degrees at 2.5T : about 3.8E9 inelastic triggers recorded

1.7 GeV, 90 degrees at 2.5 T : about 3.2E9 inelastic triggers recorded

<PT>+ = 30%@ 2.5T

<PT> = 75% @ 5T

DAQ Rate 6-7kHz with less than 30% Deadtime

Page 46: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Polarized Ammonia TargetPolarized Ammonia Target

5 T/ 140 GHz or 2.5 T/70 GHz operation Helmholtz superconduct magnet

1K 4He evaporation refrigerator Cooling power: about 1 W

Microwave Power >1W at 140 GHz

Insulated cryostat 85 L Liquid He resevoir 57 L Liquid N shield (300K BB shield)

Dynamic Nuclear Polarization of NH3

Has performed remarkably well after target grouptransplanted the Hall B coil package

Page 47: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Polarized Ammonia TargetPolarized Ammonia Target

Dynamic Nuclear Polarization of NH3

Has performed remarkably well after target grouptransplanted the Hall B coil package

NH3

NH3

Carbon

Dummy

CH2

Empty

Page 48: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Online Polarimetry

Average Polarization

>30% at 2.5 Tesla/70 GHz

courtesy James Maxwell

Page 49: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Decay with accumulateddose was very slowat 2.5T.

Online Polarimetry

courtesy James Maxwell

Page 50: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Online Polarimetry

courtesy James Maxwell

Average Polarization

>75% at 5.0 Tesla/140 GHz

Page 51: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Third Arm

courtesy Kalyan Allada and Chao Gu

Measure the asymmetry of the elastic recoil proton

Relative measurement of the product PBPT

Non-magnetic: sampling set by the trigger threshold

Very useful as an independent Beam position monitor.

Page 52: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Optics

courtesy Jixie Zhang and Min Huang

Right Septa Before/After surgery

Right Septum field is no longer symmetric or uniformHorizontal bending of the e’ depends on vertical position/angledistorts the sieve pattern

Page 53: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Beamline Diagnostics

Massive effort to commission new BPMsBCMsHarpsTungsten Calo

to operate Hall a beam at < 100 nA

courtesy Pengia Zhu

Page 54: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Normalized Yields

E=2.2 GeV Left Arm

Proton Elastic/N Q.E.

Nitrogen Elastic

Delta Resonance

E-E’ (MeV) courtesy Ryan Zielinski

Page 55: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Detector Performance

courtesy Melissa Cummings

Page 56: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

E=2.2 GeV Left Arm

Excellent reproducibilityin normalization factors

Normalized Yields

courtesy Ryan Zielinski

Page 57: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Excellent reproducibilityin normalization factors

Normalized Yields

courtesy Ryan Zielinski

Page 58: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Acceptance effects becomes much more pronounced at low momentum

Normalized Yields

E=1.7 GeV E=2.2 GeV

courtesy Ryan Zielinski

Page 59: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Asymmetries

courtesy Toby Badman

VERY VERY PRELIMINARY!

Page 60: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Asymmetries

courtesy Toby Badman

VERY VERY PRELIMINARY!

Page 61: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Asymmetries

E=2.2 GeV Elastic

courtesy Toby Badman

VERY VERY PRELIMINARY!

Page 62: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Asymmetries

courtesy Toby Badman

VERY

VERY

PREL

IMIN

ARY!

Page 63: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

courtesy Toby Badman

VERY VERY PRELIMINARY!

VERY VERY PRELIMINARY!

Page 64: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

courtesy Toby Badman

VERY VERY PRELIMINARY!

Page 65: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

Summary

Long string of mechanical problems, But accomplished most of our physics goals

Right septa compromised significantly, but made it until the final day when we scavanged its power supply

Will be challenge to understand the optics

Beamline diagnostics worked well in range 50-100 nA.

Third Arm worked well, summed over all statistics we expect a 10% PbPT

E08-027 will provide the definitive measurement of g2 and GE/GM at low Q2

Page 66: Karl Slifer University of New Hampshire Jefferson Lab User Group Meeting 6/5/2012.

backups