With an extensive range of products for many of today’s modern construction requirements, J & P Building Systems have developed a reputation for providing safe, smart solutions.

Supplying standard off-the-shelf products and bespoke designed solutions, J&P work closely with our parent companies to provide cost-effective, high quality and reliable products to benefit the construction industry.

Alongside our range of products we also have an experienced team providing design guidance, technical support, sales and pricing assistance – to ensure our customers are supplied the most suitable value-engineered products and solutions for their projects.

J&P Building Systems

Page 3: J&P Building Systems Ltd - An Introduction

J&P Parent Partnership Companies

J&P Building Systems is the supply partner in the UK for our parent companies

Page 4: J&P Building Systems Ltd - An Introduction

Balcon connectors for steel balconies

Page 5: J&P Building Systems Ltd - An Introduction

Steel balconies are a common feature of apartments

Page 6: J&P Building Systems Ltd - An Introduction

They are normally fixed to the face of the insitu concrete floor slab

Page 7: J&P Building Systems Ltd - An Introduction

Until recently, proprietary fixing systems were always used

Page 8: J&P Building Systems Ltd - An Introduction

Typical proprietary balcony fixing inserts

Page 9: J&P Building Systems Ltd - An Introduction

Apart from cost, the big drawback with these systems is tolerance

-or lack of it

Page 10: J&P Building Systems Ltd - An Introduction

Extract from proprietary technical literature

Page 11: J&P Building Systems Ltd - An Introduction

The lack of tolerance means that surveys and retro-drilling is usually required

Page 12: J&P Building Systems Ltd - An Introduction

Threaded rods projecting from slab edge

Page 13: J&P Building Systems Ltd - An Introduction

Threaded sockets cast into slab edge

Page 14: J&P Building Systems Ltd - An Introduction
Page 15: J&P Building Systems Ltd - An Introduction

Balcon channel inserts

Page 16: J&P Building Systems Ltd - An Introduction

Cast-in channel has always been known to offer high tolerance

Page 17: J&P Building Systems Ltd - An Introduction

Invented by Anders Jordahl in 1913, it has a proven track record of safety and provision of high tolerance.

Page 18: J&P Building Systems Ltd - An Introduction

In particular, channel allows considerable errors in casting to be overcome with no remedial work required.

Page 19: J&P Building Systems Ltd - An Introduction

Ideal position for channel and balcony plate

Page 20: J&P Building Systems Ltd - An Introduction

Channel to one side - plate remains in correct position

Page 21: J&P Building Systems Ltd - An Introduction

Channel too high - plate remains in correct position

Page 22: J&P Building Systems Ltd - An Introduction

Channel rotated - plate remains in correct position

Page 23: J&P Building Systems Ltd - An Introduction

Balcon system

The channels are cast-in, with bars welded-on.The stub and back plate normally form part of the balcony package

Page 24: J&P Building Systems Ltd - An Introduction

How does it work?

Page 25: J&P Building Systems Ltd - An Introduction

How does it work?

Shear is taken by the vertical toothed channels

Page 26: J&P Building Systems Ltd - An Introduction

How does it work?

Moment is taken by tension in the top channel and compression against the vertical channels

Page 27: J&P Building Systems Ltd - An Introduction

Thermal performance

The stub beam can be encased in a block of insulation.The thickness of insulation is not ‘fixed’ as with the proprietary systems.

Page 28: J&P Building Systems Ltd - An Introduction

Thermal performance

The Balcon system has been thermally assessed by BBA.

Page 29: J&P Building Systems Ltd - An Introduction

Thermal performance

The results showed that Balcon was thermally superior to existing proprietary systems.

Page 30: J&P Building Systems Ltd - An Introduction

Thermal performance

Importantly, the analysis showed that the performance meet the criteria for minimising the risk of internal surface condensation.

Page 31: J&P Building Systems Ltd - An Introduction

Durability

The channels and bolts have a hot-dipped galvanized finish. The minimum thickness of galvanizing is 50μm (microns).

The Galvanizers Association publish guidance based on BS EN ISO 14713:2009

This indicates a coating life expectancy of at least 70 years.

Page 32: J&P Building Systems Ltd - An Introduction

Practical details

BBC Media City

Page 33: J&P Building Systems Ltd - An Introduction

Practical details

BBC Media City

Page 34: J&P Building Systems Ltd - An Introduction

Practical details

BBC Media City

Page 35: J&P Building Systems Ltd - An Introduction

Practical details

Clancy Barracks, Dublin

Page 36: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Woodberry Down

Page 37: J&P Building Systems Ltd - An Introduction

Balcon Case studies

BBC Media City

Media City

Page 38: J&P Building Systems Ltd - An Introduction

Balcon Case studies

The Rock, Bury

Page 39: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Clancy Barracks, Dublin

Page 40: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Beaufort Park, Hendon

Page 41: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Kew Bridge Road, Brentford

Page 42: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Finzels Reach, Bristol

Finzels Reach, Bristol

Page 43: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Finzels Reach, Bristol

Finzels Reach, Bristol

Page 44: J&P Building Systems Ltd - An Introduction

Balcon Case studies

Olympic Athletes Village (3 sites)

Page 45: J&P Building Systems Ltd - An Introduction

In addition:

Cast-in channels are remarkably tolerant of mis-use and abuse, as these examples show.

Page 46: J&P Building Systems Ltd - An Introduction

Channel not secured before casting has sunk below the surface of the concrete.

Concrete is highly honeycombed

Used after load testing.

Page 47: J&P Building Systems Ltd - An Introduction

After this channel was missed out, the Contractor cut a chase in the column and ‘fixed’ a channel with resin.

Rejected!

Page 48: J&P Building Systems Ltd - An Introduction

After this channel was mis-positioned, the Contractor added another, with resin.

Rejected!

Page 49: J&P Building Systems Ltd - An Introduction

The missing concrete was replaced with grout.

Used after load testing.

Page 50: J&P Building Systems Ltd - An Introduction

This group was severely mis-aligned, and the lower surface was set back.

After load testing, this was used as designed with a modified end plate to the beam.

Page 51: J&P Building Systems Ltd - An Introduction

Inappropriate use of an oxyacetylene burner damaged the galvanizing. Concrete was blown off by the extreme heat.

After making-good, and load testing, this was used as designed.

Load = 70 kNm + 100 kN

Page 52: J&P Building Systems Ltd - An Introduction

J&P Building Systems LtdThame Forty Jane Morbey Road

Thame Oxon OX9 3RRT: +44 (0)1844 215 200 F: +44 (0)1844 263 257

E: [email protected]: jp-uk.com

GENERAL

Page 53: J&P Building Systems Ltd - An Introduction

- THANK YOU -