J&P Building Systems Ltd - ISOPRO Balcony Connectors

45
J&P Building Systems Ltd ISOPRO Balcony Connectors

description

ISOPRO Balcony Connectors

Transcript of J&P Building Systems Ltd - ISOPRO Balcony Connectors

Page 1: J&P Building Systems Ltd - ISOPRO Balcony Connectors

J&P Building Systems LtdISOPRO Balcony Connectors

Page 2: J&P Building Systems Ltd - ISOPRO Balcony Connectors

J&P Parent Partnership Companies

J&P Building Systems is the supply partner in the UK for our parent companies

Page 3: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO

Page 4: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO - What is it for?

ISOPRO is the answer to thermal bridging problems in concrete constructions.

ISOPRO is the thermal break!

Page 5: J&P Building Systems Ltd - ISOPRO Balcony Connectors

What does the problem look like?

Page 6: J&P Building Systems Ltd - ISOPRO Balcony Connectors

What does the problem look like?

Page 7: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Thermal bridges are local component areas in building envelope with increased heat loss.

Because of increased heat loss there is a lowering of internal surface temperature.

If these fall below the minimum surface temperature si of 12,6°C , it promotes mould growth.

Definition of thermal bridges

Page 8: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO - positive effects

Reduces loss of heat

Saves heating energy

Creates higher surface temperature inside

Adds to a more comfortable residential climate

Reduces building deficiencies

Reduces CO2 emission

Page 9: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Theoretical with 100 % insulation

Isopro

Page 10: J&P Building Systems Ltd - ISOPRO Balcony Connectors

There is no such thing as a thermal break!

The best you can hope for is the minimal disruption of the insulation

All structural systems compromise the insulation to some extent

Page 11: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Balcony connected by continuous concrete construction – no thermal provision

Page 12: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Temp < 12.6 deg= risk of mould

Page 13: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Balcony connected to slab with 100% thermal break

Page 14: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Balcony connected to slab with ISOPRO – with insulation

Page 15: J&P Building Systems Ltd - ISOPRO Balcony Connectors
Page 16: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Cantilevering balcony Balcony on columns

Page 17: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Tension bars:

Stainless steel - black steel welded

Shear load bars:

Stainless steel- black steel welded

Pressure bearing:

Special high-strength concrete with sliding bearing

Static elements of ISOPRO

Page 18: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO Type IPT

Page 19: J&P Building Systems Ltd - ISOPRO Balcony Connectors

bending moment

traction - tension bars

pressure - concrete pressure bearings

Shear load

Shear load - shear load bars

The way ISOPRO works ...

Page 20: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO - installed in a building with facing brick

Page 21: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO in prefabrication

Page 22: J&P Building Systems Ltd - ISOPRO Balcony Connectors

If there is a requirement for fire resistance class F-90 then the ISOPRO elements are equiped with a fireproofing plate

ISOPRO – fire protection F90

Page 23: J&P Building Systems Ltd - ISOPRO Balcony Connectors

1. Concept of working loads (service loads)

2. Concept of design loads (assumed loads)

3. Concept of failure loads (ultimate loads)

Design concepts

Page 24: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Calculating force

Material

Safety factor 1.0

Safety depends on material (normaly 50 – 80 %)

Concept of working loads

Page 25: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Calculating force

Material

Safety factor on dead loads 1.35

Safety factor on live loads 1.50

Safety depends on material (normally 15 %)

Concept of design loads

Page 26: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Calculating force

material

safety factor normally 1.7 – 1.9

safety on material minimal (normally 5 %)

Concept of failure loads

Page 27: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Dimension of balcony and loads

Example of design

Page 28: J&P Building Systems Ltd - ISOPRO Balcony Connectors

gpermanent = 1.00g

v ariable = 1.00

Safety factors

Forces

Choosen ISOPRO, permissible loads

Example of design

working loads

Client: Formaco

Project: Presentation

Editor: Björn Wingerter

component balcony corbeling out free system

F1

lk = 1.80 [m] overhang

q F2 h d = 20.0 [cm] board thickness

d2 = 4.5 [cm] coating

lk1 = 1.92 [m] axis of structural design

lk = 1.80 m h = 1.10 [m] height of balustrade

gpermanent = 1.00gv ariable = 1.00

loading g1 = dead load = 5.00 [kN/m²]g2 = coating = 0.99 [kN/m²]

p = live load = 4.00 [kN/m²]

q = area load factored = 9.99 [kN/m²]

F1 = horizontal load = 0.50 [kN/m]F2 = balustrade 1.00 [kN/m]

F1 = lineload factored = 0.50 [kN/m]F2 = lineload factored = 1.00 [kN/m]

cuttingforce m = 20.81 [kNm/m]

v = 18.98 [kN/m]

dimensioning

choosing: IP 12/8 B = 20 cm mRd = 25.0 [kNm/element]

vRd = 29.0 [kN/element]

Calculation has to be proved and released!

date 19/10/2012 static compiled: i.A.signature

Am GüterbahnhofD-79771 Klettgau 1

Tel.: 07742 - 92 15 20

TYPECERTIFICATED

Page 29: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Client: Formaco

Project: Presentation

Editor: Björn Wingerter

component balcony corbeling out free system

F1

lk = 1,80 [m] overhang

q F2 h d = 20,0 [cm] board thickness

d2 = 4,5 [cm] coating

lk1 = 1,92 [m] axis of structural design

lk = 1,80 m h = 1,10 [m] height of balustrade

gpermanent = 1,35g

v ariable = 1,50

loading g1 = dead load = 5,00 [kN/m²]g2 = coating = 0,99 [kN/m²]

p = live load = 4,00 [kN/m²]

q = area load factored = 14,09 [kN/m²]

F1 = horizontal load = 0,50 [kN/m]F2 = balustrade 1,00 [kN/m]

F1 = lineload factored = 0,68 [kN/m]F2 = lineload factored = 1,35 [kN/m]

cuttingforce m = 29,20 [kNm/m]

v = 26,71 [kN/m]

dimensioning

choosing: IP 12/7 B = 20 cm mRd = 33,7 [kNm/element]

vRd = 41,5 [kN/element]

Calculation has to be proved and released!

date 15.05.2007 static compiled: i.A.signature

Am GüterbahnhofD-79771 Klettgau 1

Tel.: 07742 - 92 15 20Fax: 07742 - 92 15 96

TYPECERTIFICATED

gpermanent = 1.35g

v ariable = 1.50

Safety factors

Forces

Choosen ISOPRO, permissible loads

Example of design

design loads

Page 30: J&P Building Systems Ltd - ISOPRO Balcony Connectors

gpermanent = 1.00g

v ariable = 1.00

Safety factors

Forces

choosen ISOPRO, permissible loads

working loads design loads

gpermanent = 1.35g

v ariable = 1.50

Safety factors

Forces

choosen ISOPRO, permissible loads

Example of design

Comparison of calculation

Page 31: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Balkon

WandIso

Var.l

Wall

BalconyBalkon

WandIso

Var.ll

Wall

Balcony

ISOPRO Var. I

Connecting a balcony to a wall downward

ISOPRO Var. IIConnecting a balcony to a wall

upward

ISOPRO - Variations

Page 32: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO

Balkon

Decke

WandIso

ISOPRO Var. III

Connecting a balcony to a ceiling with offset

Connecting a balcony to a ceiling with a small offset

Balcony

Balcony

CeilingCeiling

ISOPRO - Variations

Balkon

Decke

WandIso

Var.lll

Page 33: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Balkon einspringend

IPTD IPTD

ISOPRO – Type IPTD

Page 34: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO – elements for bending moment and shear

Type IPT

Type IP Type IPT corner

Type IPTD

Page 35: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO – elements for shear

Type IPQ

Type IPQQType IPQQS

Type IPQS

Page 36: J&P Building Systems Ltd - ISOPRO Balcony Connectors

160-240

Connecting a roof parapet to a ceiling

ISOPRO – Type IPA

Page 37: J&P Building Systems Ltd - ISOPRO Balcony Connectors

ISOPRO – Type IPF

Connecting a balustrade to a ceiling

Page 38: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Connecting a console to a ceiling

Gleitfolie

Stahlbeton-konsole

Weichfaser-platte

150-160 60

ISOPRO – Type IPO

Page 39: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Connecting a concrete beam to a ceiling / wall

ISOPRO – Type IPS

Page 40: J&P Building Systems Ltd - ISOPRO Balcony Connectors

Connecting a wall element to a wall

ISOPRO – Type IPW

Page 41: J&P Building Systems Ltd - ISOPRO Balcony Connectors
Page 42: J&P Building Systems Ltd - ISOPRO Balcony Connectors

In addition to the numerous European product quality approvals of our parent companies, J&P is locally committed to the highest standards of manufacture and environmental awareness.

UK CARES ISO 9001 ISO 14001 Green Achiever

GENERAL

Additional information

Page 43: J&P Building Systems Ltd - ISOPRO Balcony Connectors

In addition to the products we supply J&P Building Systems have developed an enviable reputation for providing our customers:

• Design assistance• Bespoke fabrications• CPD Seminars• On-site support• Technical guidance

GENERAL

Additional information

Page 44: J&P Building Systems Ltd - ISOPRO Balcony Connectors

J&P Building Systems LtdThame Forty Jane Morbey Road

Thame Oxon OX9 3RRT: +44 (0)1844 215 200 F: +44 (0)1844 263 257

E: [email protected]: jandpbuildingsystems.com

GENERAL

Page 45: J&P Building Systems Ltd - ISOPRO Balcony Connectors

- THANK YOU -